Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 750
Filter
1.
Rehabilitación (Madr., Ed. impr.) ; 58(2): 1-10, abril-junio 2024.
Article in Spanish | IBECS | ID: ibc-232112

ABSTRACT

Introducción y objetivo: Obtener un nuevo punto de corte (PC) para un test de flexión-relajación (FR) lumbar efectuado con electrodos (e.) tetrapolares, desde valores ya definidos con dispositivos bipolares.Materiales y métodosLa muestra del estudio consta de 47 pacientes en situación de incapacidad temporal por dolor lumbar (DL). Fueron evaluados mediante un test de dinamometría isométrica, una prueba cinemática y una valoración del fenómeno FR.Se plantean dos experimentos con curvas ROC. El primero, con 47 pacientes que efectuaron de modo consecutivo el test FR con ambos tipos de electrodos, utilizándose como variable de clasificación el punto de corte conocido para los e. bipolares (2,49uV). En el segundo, con los datos de la EMGs registrados con e. tetrapolares en 17 pacientes, se efectúa un test de DeLong que compara las 2 curvas ROC que construimos, por un lado, al clasificar la muestra desde pruebas de dinamometría y cinemática, y por el otro, al clasificarlos con los valores de la EMGs bipolar.ResultadosUn total de 34 pacientes completaron adecuadamente las valoraciones del primer experimento y 17 pacientes el segundo. El primer estudio arroja un punto de corte de 1,2uV, con un AUC del 87,7%; sensibilidad 84,2% y especificidad 80%. El segundo muestra un PC para los e. bipolares de 1,21uV (AUC 87,5%) y para los e. tetrapolares de 1,43 (AUC 82,5%) con un test de DeLong sin diferencias significativas entre ambas curvas (p>0,4065).ConclusionesLa metodología de validación con curvas ROC ha permitido obtener un nuevo PC para la prueba FR de modo práctico, simplemente simultaneando ambos test sobre el mismo grupo de pacientes hasta obtener una muestra significativa. (AU)


Introduction and objective: To obtain a new cut-off point (CP) for a lumbar flexion-relaxation (RF) test established with tetrapolar (e.) electrodes, from values already defined with bipolar devices.Materials and methodsThe study sample consists of 47 patients in a situation of temporary disability due to low back pain (DL). They were evaluated by means of an isometric dynamometry test, a kinematic test and an assessment of the FR phenomenon.Two experiments with ROC curves are proposed. The first, with 47 patients who consecutively performed the RF test with both types of electrodes, using the cut-off point (CP) known for the e. bipolar (2.49μV). In the second, with the EMG data recorded with e. tetrapolar in 17 patients, a DeLong test was performed that compares the 2 ROC curves that were constructed on the one hand, by classifying the sample from dynamometry and kinematic tests, and on the other, by classifying them with the bipolar EMG values.ResultsA total of 34 patients adequately completed the evaluations of the first experiment and 17 patients the second. The first study shows a cut-off point of 1.2μV, with an AUC of 87.7%; Sensitivity 84.2% and Specificity 80%. The second shows a PC for e. bipolars of 1.21μV (AUC 87.5%) and for e. tetrapolar values of 1.43 (AUC 82.5%) with a DeLong test without significant differences between both curves (p>0.4065).ConclusionsThe validation methodology with ROC curves has made it possible to obtain a new PC for the RF test in a practical way, simply by simultaneously performing both tests on the same group of patients until a significant sample is obtained. (AU)


Subject(s)
Low Back Pain , Flexural Strength , Muscle Relaxation , ROC Curve
2.
Dental Press J Orthod ; 29(2): e2423282, 2024.
Article in English | MEDLINE | ID: mdl-38775601

ABSTRACT

OBJECTIVE: This study aimed to compare the insertion torque (IT), flexural strength (FS) and surface alterations between stainless steel (SS-MIs) and titanium alloy (Ti-MIs) orthodontic mini-implants. METHODS: Twenty-four MIs (2 x 10 mm; SS-MIs, n = 12; Ti-MIs, n = 12) were inserted on artificial bone blocks of 20 lb/ft3 (20 PCF) and 40 lb/ft3 (40 PCF) density. The maximum IT was recorded using a digital torque meter. FS was evaluated at 2, 3 and 4 mm-deflection. Surface topography and chemical composition of MIs were assessed by scanning electron microscopy (SEM) and energy dispersive X-ray spectroscopy (EDS). General linear and mixed models were used to assess the effect of the MI type, bone density and deflection on the evaluated outcomes. RESULTS: The IT of Ti-MIs was 1.1 Ncm greater than that obtained for the SS-MIs (p= 0.018). The IT for MIs inserted in 40 PCF test blocks was 5.4 Ncm greater than that for those inserted in 20 PCF test blocks (p < 0.001). SS-MIs inserted in higher density bone (40 PCF) had significantly higher flexural strength than the other groups, at 2 mm (98.7 ± 5.1 Ncm), 3 mm (112.0 ± 3.9 Ncm) and 4 mm (120.0 ± 3.4 Ncm) of deflection (p< 0.001). SEM evidenced fractures in the Ti-MIs. EDS revealed incorporation of 18% of C and 2.06% of O in the loaded SS-MIs, and 3.91% of C in the loaded Ti-MIs. CONCLUSIONS: Based on the findings of this in vitro study, it seems that SS-MIs offer sufficient stability and exhibit greater mechanical strength, compared to Ti-MIs when inserted into higher density bone.


Subject(s)
Dental Alloys , Dental Implants , Flexural Strength , Materials Testing , Microscopy, Electron, Scanning , Orthodontic Anchorage Procedures , Stainless Steel , Surface Properties , Titanium , Torque , Titanium/chemistry , Stainless Steel/chemistry , Orthodontic Anchorage Procedures/instrumentation , Orthodontic Anchorage Procedures/methods , Dental Alloys/chemistry , In Vitro Techniques , Spectrometry, X-Ray Emission , Dental Stress Analysis , Humans , Stress, Mechanical , Bone Density
3.
BMC Oral Health ; 24(1): 546, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730400

ABSTRACT

BACKGROUND: Recently, a new generation of high-strength flowable dental composites has been introduced by manufacturers. The manufacturers claim that these materials have enhanced mechanical and physical properties and are suitable for use in a wide range of direct anterior and posterior restorations, even in high-stress bearing areas. AIM: The objective of this study was to assess certain physical and mechanical properties of these recently introduced high-strength flowable composites in comparison to conventional multipurpose dental composites. METHODS: Four types of high-strength flowable composites (Genial Universal FLO, Gaenial Universal Injectable, Beautifil Injectable, and Beautifil Flow Plus) were tested in experimental groups, while a nanohybrid conventional composite (Filtek Z350 XT) was used as the control. For flexure properties, ten rectangular samples (2 × 2 × 25 mm) were prepared from each composite material and subjected to 5000 cycles of thermocycling. Samples were then subjected to flexural strength testing using the universal testing machine. Another twenty disc-shaped specimens of dimensions (5 mm diameter × 2 mm thickness) were fabricated from each composite material for surface roughness (Ra) (n = 10) and hardness (VHN) test (n = 10). All samples underwent 5000 cycles of thermocycling before testing. Additionally, microleakage testing was conducted on 60 standardized class V cavities prepared on molar teeth and divided randomly into five groups (n = 12). Cavities were then filled with composite according to the manufacturer's instructions and subjected to thermocycling for 1000 cycles before testing using methylene blue solution and a stereomicroscope. RESULTS: All tested materials were comparable to the control group in terms of flexural strength and surface roughness (p > 0.05), with Gaenial Universal FLO exhibiting significantly higher flexural strength compared to the other flowable composite materials tested. However, all tested materials demonstrated significantly lower elastic modulus and surface hardness than the control group (p < 0.05). The control group exhibited higher microleakage scores, while the lowest scores were observed in the Gaenial Universal FLO material (p < 0.05) CONCLUSION: The physical and mechanical behaviors of the different high-strength flowable composites investigated in this study varied. Some of these materials may serve as suitable alternatives to conventional composites in specific applications, emphasizing the importance of dentists being familiar with material properties before making material selections.


Subject(s)
Composite Resins , Dental Leakage , Flexural Strength , Hardness , Materials Testing , Surface Properties , In Vitro Techniques , Humans , Dental Stress Analysis , Dental Materials/chemistry , Stress, Mechanical , Polyethylene Glycols , Polymethacrylic Acids/chemistry , Bisphenol A-Glycidyl Methacrylate
4.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(2): 345-351, 2024 Apr 18.
Article in Chinese | MEDLINE | ID: mdl-38595256

ABSTRACT

OBJECTIVE: To analyze the influence of forming direction on the surface characteristics, elastic modulus, bending strength and fracture toughness of printed parts and the relationship between forming direction and force direction, and to provide scientific basis and guidance for the clinical application of oral denture base resin materials. METHODS: The 3D printing technology was used to print denture base resin samples. The shape and size of the samples referred to the current standard for testing conventional denture base materials. The samples used for physical performance testing were cylindrical (with a diameter of 15 mm and a thickness of 1 mm) and printed at different angles along the Z axis (0°, 45°, 90°). Scanning electron microscope was used to observe the microscopic topography of the different samples. The color stability of different samples was observed by color stabilizer. The surface roughness of the samples was analyzed by using surface roughness tester. The Vickers hardness was measured to analyze the hardness of the samples. The samples used for mechanical performance testing were rectangular (elastic modulus and bending strength: A length of 64 mm, a width of 10 mm, and a height of 3.3 mm; fracture toughness: A length of 39 mm, a width of 8 mm, and a height of 4 mm), divided into two groups: W group and H group. The W group was printed from the bottom up along the Z axis with the length × width as the bottom surface parallel to the X, Y axis plane, while the H group printed from the bottom up along the Z axis with the length × height as the bottom surface parallel to the X, Y axis plane. The forming angles of both groups were equally divided into 0°, 45°, and 90°. The elastic modulus, bending strength and fracture toughness of different samples were studied through universal mechanical testing machine. SPSS 22.0 software was used for statistical analysis. RESULTS: The microscopic topography and roughness of different samples were closely related to the printing direction, with significant differences between the 0°, 45°, and 90° specimens. The 0° specimens had the smoothest surface (roughness < 1 µm). The surface of the 45° specimen was the roughest (roughness>3 µm). The microhardness of the 0° sample was the best [(196.13±0.20) MPa], with a significant difference compared with the 90° sample [(186.62±4.81) MPa, P < 0.05]. The mechanical properties of different samples were also closely related to the printing direction. The elastic modulus, bending strength, and fracture toughness of the 45° samples in the W group were the highest compared with the other groups. The results of elastic modulus showed that in the H group, the 45° specimens had the highest elastic mo-dulus, which was significantly different from the 0° and 90° specimens (P < 0.05). The elastic modulus of 0° and 45° specimens in the W group were higher than those in 90° specimens (P < 0.05). The bending strength results showed that there was no significant difference between the specimens from dif-ferent angles in the H group. The bending strength of the 90° specimens in the W group was the smallest, and there was a significant difference between 90° and the 0° and 45° specimens (P < 0.05); And the bendind strength of the 0° and 45° specimens in the W group was significantly higher than that of the 0° and 45° specimens in the H group (P < 0.05). The fracture toughness results showed that the fracture toughness of the H group specimens was lower than 1.9 MPa m1/2, which was specified in the denture base standard. The 45° samples in the W group were the highest, with significant differences compared with the 0° and 90° samples (P < 0.05). And the 90° samples of the W group specimens were lower than 1.9 MPa m1/2. And the fracture toughness of the 45° specimen in the W group was significantly higher than that of all the specimens in the H group (P < 0.05). CONCLUSION: The 0° samples had relatively better physical properties. The 45° samples had the best mechanical properties. But the fracture toughness of specimens (H group and 90° samples of W group) did not yet meet clinical requirements. That indicated that the characteristics of the 3D printing denture base resin were affected by the printing direction. Only when the performance of the printed samples in all directions met the minimum requirements of the standard, they could be used in clinical practice.


Subject(s)
Printing, Three-Dimensional , Prosthodontics , Materials Testing , Surface Properties , Flexural Strength , Denture Bases
5.
J Indian Prosthodont Soc ; 24(2): 165-174, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38650342

ABSTRACT

AIM: (1) To assess the release of stable silver nanoparticles (AgNPs) of small scale dimension added to heat polymerized polymethyl methacrylate (PMMA) in 6 months. (2) Assessing the influence of incorporating minimal concentrations of stable AgNPs with nanoscale dimensions into heat polymerized PMMA over a 6 month period on its antifungal efficacy (AF), flexural strength (FS), and impact strength (IS). SETTINGS AND DESIGN: Incorporating nanoparticles with a very small scale may have minimal impact on mechanical properties due to their diminutive size. However, the influence of these small scaled nanoparticles on antimicrobial efficacy and potential escalation in toxicity to host cells through leaching remains unexplored. AgNPs were prepared using an Ultrasonic Probe sonicator and the addition of ammonia to obtain stabilized AgNPs (< 0.01 nm) of small scale dimension. The characterization of these AgNPs involved ultraviolet visible spectroscopy, X ray diffraction, Zetasizer, and transmission electron microscopy with energy dispersive spectroscopy (TEM). MATERIALS AND METHODS: The prepared AgNPs were then added in various percentages by weight (0%-0.5%) to fabricate 252 modified PMMA samples of sizes 10 mm × 3 mm (AF, n = 108), 65 mm × 10 mm × 3 mm (FS, n = 72), and 65 mm × 10 mm × 2.5 mm (IS, n = 72) as per ADA specification no. 12. These samples underwent testing for leaching out of AgNPs and efficacy against Candida albicans for 6 months. The effect on FS and IS was evaluated using the three point bending test and Charpy's Impact Tester, respectively. STATISTICAL ANALYSIS USED: Intergroup comparison of CFU between various concentrations of AgNP was done using the Kruskal-Wallis ANOVA test succeeded by Mann-Whitney test for pair wise comparisons. Difference in CFU of various concentrations over 6 months was seen using one way ANOVA test. Intergroup comparison of FS and IS was performed using a one way ANOVA test, followed by a post hoc Tukey's test for pair wise comparisons. RESULTS: Repeated tests showed no leaching out of AgNPs from the denture base resin into the storage medium. All concentrations of AgNPs incorporated in resin showed inhibition of Candida growth. Intergroup comparison of FS and IS revealed highly statistically significant differences (F = 15.076, P < 0.01 and F = 28.266, P < 0.01) between the groups showing a reduction in strength. CONCLUSION: The AgNPs of small scale dimension incorporated into the denture base resin imparted a strong antifungal effectiveness against C. albicans, which did not decline during the study period and did not cause any release of nanoparticles. 0.5% showed the best antifungal efficacy. This may prove to be a viable and highly effective treatment for the prevention of Candida associated denture stomatitis. However, the inclusion of these particles resulted in a decrease in both FS and IS, and this reduction was directly proportional to the percentage of added AgNPs, with 0.5% demonstrating the least IS and FS.


Subject(s)
Antifungal Agents , Flexural Strength , Metal Nanoparticles , Polymethyl Methacrylate , Silver , Polymethyl Methacrylate/chemistry , Polymethyl Methacrylate/pharmacology , Silver/chemistry , Silver/pharmacology , Metal Nanoparticles/chemistry , Antifungal Agents/pharmacology , Antifungal Agents/chemistry , Candida albicans/drug effects , Materials Testing , In Vitro Techniques , Microscopy, Electron, Transmission
6.
J Dent ; 145: 104993, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38657724

ABSTRACT

OBJECTIVES: This study aimed to compare the physical and mechanical properties of four denture base materials: Polyan IC (PA), milled polymethylmethacrylate (PMMA), three-dimensional (3D)-printed resin (3DP), and SR Ivocap (SR). METHODS: Ninety-six samples were prepared and divided into four groups as follows. Group A consisted of 3DP (Asiga DentaBASE, Asiga) fabricated using a manufacturer-recommended 3D printer (Asiga Pro 4k, Asiga). Group B comprised milled PMMA (MP) (Ivotion Base, Ivoclar Vivadent). Group C included PA (BredentSenden), meanwhile, group D involved SR (Ivoclar VivadentSchaan). Cuboid samples (65 mm x 10 mm x 2.5 mm) were used for biaxial flexure strength testing in a universal testing machine (UTM). Cylindrical samples of 20 mm x 40 mm were used for compressive strength testing in a UTM. Additionally, cuboid samples (65 mm x 10 mm x 2.5 mm) were used for Vickers surface hardness testing in a microhardness tester. disk samples (10 mm x 2.5 mm) were employed for color stability testing both in a coffee solution and Coca-Cola, using a digital spectrophotometer. Statistical analyses were performed using one-way analysis of variance and Tukey's post hoc analysis (α=0.05). RESULTS: MP demonstrated superior compressive strength (p = 0.002) and color stability compared to that exhibited by 3DP (p < 0.001) while displaying similar flexure strength (p = 0.336) and hardness (p = 0.708). MP and PA displayed similar compressive strength (p = 0.081), flexure strength (p = 0.159), and color stability in coke (p = 0.071). However, MP had reduced hardness (p < 0.001) and color stability in coffee (p < 0.001). Moreover, MP demonstrated a higher compressive strength (p < 0.001) than that displayed by SR. However, the flexure strength, hardness, and color stability were similar (p > 0.05). Furthermore, 3DP exhibited comparable compressive strength (p = 0.334) to that of PA but demonstrated significantly lower flexure strength (p = 0.005), hardness (p < 0.001), and color stability (p < 0.001) compared to PA. In comparison to SR, PA had a higher compressive strength (p < 0.001), hardness (p = 0.001), and color stability in coffee (p < 0.001), although they demonstrated similar (p > 0.05) flexure strength and color stability in coke. CONCLUSIONS: The MP and PA demonstrated superior compressive strength than that exhibited by the other materials tested. The tested materials had similar flexure strengths, except for PA which demonstrated superiority over the 3DP. Among all tested materials, PA exhibited the highest hardness, while the 3DP was the least color-stable. CLINICAL SIGNIFICANCE: Considering the mechanical properties and color stability, Polyan and milled polymethylmethacrylate are preferred for complete denture fabrication. However, the limited repairability and complex handling of Polyan should be considered.


Subject(s)
Color , Dental Materials , Denture Bases , Hardness , Materials Testing , Polymethyl Methacrylate , Surface Properties , Polymethyl Methacrylate/chemistry , Dental Materials/chemistry , Compressive Strength , Acrylic Resins/chemistry , Printing, Three-Dimensional , Humans , Stress, Mechanical , Dental Stress Analysis , Flexural Strength
7.
Int J Prosthodont ; 37(7): 49-54, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38489220

ABSTRACT

PURPOSE: This study compares the fracture strengths of long-span fixed provisional restorations fabricated via digital additive and subtractive methods to those fabricated via conventional heat-processing techniques. MATERIALS AND METHODS: A six-unit anterior partial restoration was designed as an anatomical and morphologic structure using a dental CAD/CAM system. The provisional restorations (N = 40) of four different fabrication methods (n = 10 per group) were used for the failure loading test: stereolithography apparatus (SLA), liquid crystal display (LCD), milling (MIL), and heat-processed temporary (HPT). The specimens were subjected to a maximum load-to-fracture test using a universal testing machine, and the representative fracture patterns were observed. Statistical analysis was performed using Shapiro-Wilk, Kruskal-Wallis, Mann-Whitney U, and Bonferroni post hoc tests (P < .05). RESULTS: The four groups showed significant differences in fracture strength according to the materials and manufacturing methods used (P < .001, except between SLA and HPT groups). The fracture strengths of MIL and LCD digitally fabricated groups were significantly higher than that of the HPT group (P < .001). CONCLUSIONS: The subtractive method is ideal for fabricating long-span fixed provisional restorations for long-term use. Additionally, LCD additive manufacturing technology could soon be a good alternative for restorations.


Subject(s)
Computer-Aided Design , Flexural Strength , Materials Testing , Dental Prosthesis Design , Dental Stress Analysis
8.
Sci Rep ; 14(1): 6313, 2024 03 15.
Article in English | MEDLINE | ID: mdl-38491047

ABSTRACT

The design cement mix of grade 350 was created in accordance with Egyptian Standards by partially substituting the fine aggregate with WPVC waste in various weight percentages (10, 20, 30, 40, 50, 75, and 100%). A control mix with 0% replacement was also prepared. The W/C ratio was about 0.5 for all mixes. Compressive, flexure strength, bulk density, and absorption tests were studied. For WPVC replacement, until 30%, compressive strength and flexure strength are acceptable with respect to standerds. Thermal treatment at 200 °C improves the compressive strength, flexure strength and water absorption for 20% WPVC only. The dielectric properties of all cement paste mixes before and after heat treatment, over a frequency range (0.1-106 Hz), were measured as a function of frequency. For dielectric properties and conductivity, an improvement was obtained until 30% WPVC. After this percentage, the dielectric properties and the conductivity got worse. So, cement paste with 30% WPVC as replacement of sand is the optimum ratio with conductivity in range of 10-12 S/cm, which is a good choice for antistatic cement paste applications (10-10-10-12 S/cm). The antimicrobial efficacy of the prepared cement samples of WPVC concentrations (0, 20 and 30) % were studied, the number of grown microbial colonies decreased for all the samples compared to control tap water and decreased by introducing WPVC into the cement paste sample. So, it is recommended to use these samples in places that should be carefully shielded from bacterial infections and static electric charge dangers.


Subject(s)
Bone Cements , Construction Materials , Compressive Strength , Flexural Strength , Water
9.
Dent Mater J ; 43(2): 294-302, 2024 Mar 29.
Article in English | MEDLINE | ID: mdl-38432949

ABSTRACT

This study aimed to clarify the effects of multiple firings on the translucency, crystal structure, and mechanical strength of highly translucent zirconia. Four types of highly translucent zirconia (LAVA Esthetic, LAVA Plus, KATANA Zirconia STML, and KATANA Zirconia HTML) were fired three times at three different temperatures, and the translucency, crystal structure, and flexural strength were evaluated before and after firing. The translucency was statistically compared using repeated-measures analysis of variance; the zirconia phase composition was assessed using X-ray diffraction followed by Rietveld analysis; and the biaxial flexural strength was assessed using Weibull analysis. The translucency of LAVA Esthetic and KATANA Zirconia HTML decreased significantly after firing, and the crystal composition of LAVA Plus and KATANA Zirconia HTML changed after multiple firings, whereas multiple firings did not affect the biaxial flexural strength of any samples. Thus, multiple firings may affect the optical properties of highly translucent zirconia.


Subject(s)
Dental Materials , Flexural Strength , Dental Materials/chemistry , Materials Testing , Zirconium/chemistry , Ceramics/chemistry , Surface Properties
10.
Int J Prosthodont ; 37(7): 133-141, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38498865

ABSTRACT

PURPOSE: To evaluate the flexural strength (FS) and microhardness of various CAD/CAM restorative materials intended for definitive use. The effect of hydrothermal aging on the mechanical properties of these materials was also investigated. MATERIALS AND METHODS: A total of 210 bar-shaped specimens (17 × 4 × 1.5 mm ± 0.02 mm) were fabricated via either subtractive manufacturing (SM) methods-reinforced composite resin (SM-CR), polymer-infiltrated ceramic network (SM-PICN), fine-structured feldspathic ceramic (SMFC), nanographene-reinforced polymethyl methacrylate (PMMA; SM-GPMMA), PMMAbased resin (SM-PMMA)-or additive manufacturing (AM) methods with urethane acrylate-based resins (AM-UA1 and AM-UA2). Specimens were then divided into two subgroups (nonaged or hydrothermal aging; n = 15). A three-point flexural strength test was performed, and five specimens from the nonaged group were submitted to microhardness testing. Specimens were subjected to 10,000 thermal cycles, and the measurements were repeated. RESULTS: Regardless of aging, SM-CR had the highest FS (P < .001), followed by SM-GPMMA (P ≤ .042). In nonaged groups, AM-UA2 had a lower FS than all other materials except SM-FC (P = 1.000). In hydrothermal aging groups, AM specimens had lower FS values than other materials, except SM-PMMA. With regard to microhardness, there was no significant difference found between any of the tested materials (P ≥ .945) in the nonaged and hydrothermal aging groups. CONCLUSIONS: The effect of hydrothermal aging on FS varied depending on the type of restorative material. Regardless of aging condition, SM-CR showed the highest FS values, whereas SM-FC had the highest microhardness. Hydrothermal aging had no significant influence on the microhardness of the tested materials.


Subject(s)
Flexural Strength , Polymethyl Methacrylate , Dental Materials , Composite Resins , Polymers , Materials Testing , Surface Properties , Computer-Aided Design
11.
BMC Oral Health ; 24(1): 357, 2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38509542

ABSTRACT

BACKGROUND: This study compared the impact of thermal cycling on the flexural strength of denture-base materials produced through conventional and digital methods, using both subtractive and additive approaches. METHODS: In total, 60 rectangular specimens were fabricated with specific dimensions for flexural strength tests. The dimensions were set according to the International Organization for Standardization (ISO) guideline 20795-1:2013 as 64 × 10 × 3.3 ± 0.2 mm. Specimens from each material group were divided into two subgroups (thermal cycled or nonthermal cycled, n = 10/group). We used distinct methods to produce three different denture-base materials: Ivobase (IB), which is a computer-aided-design/computer-aided-manufacturing-type milled pre-polymerized polymethyl methacrylate resin disc; Formlabs (FL), a 3D-printed denture-base resin; and Meliodent (MD), a conventional heat-polymerized acrylic. Flexural strength tests were performed on half of the samples without a thermal-cycle procedure, and the other half were tested after a thermal cycle. The data were analyzed using a two-way analysis of variance and a post hoc Tukey test (α = 0.05). RESULTS: Based on the results of flexural-strength testing, the ranking was as follows: FL > IB > MD. The effect of thermal aging was statistically significant for the FL and IB bases, but not for the MD base. CONCLUSIONS: Digitally produced denture bases exhibited superior flexural strength compared with conventionally manufactured bases. Although thermal cycling reduced flexural strength in all groups, the decrease was not statistically significant in the heat-polymerized acrylic group.


Subject(s)
Flexural Strength , Hot Temperature , Humans , Acrylic Resins , Denture Bases , Materials Testing , Polymethyl Methacrylate , Surface Properties
12.
J Oral Sci ; 66(2): 120-124, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38494704

ABSTRACT

PURPOSE: To evaluate the flexural properties of repaired poly(methylmethacrylate) (PMMA) denture base materials for computer-aided design/computer-aided manufacturing (CAD-CAM) and to compare them with heat-activated polymerized PMMA. METHODS: A total of 288 specimens (65 × 10 × 2.5 mm) were prepared using both CAD-CAM and conventional blocks and repaired using autopolymerizing and visible-light polymerizing (VLC) materials. Microwave energy, water storage and hydroflask polymerization were applied as additional post-polymerization cycles after the repair process. The flexural strength (FS) of the specimens was evaluated using the three-point bending test. Data were evaluated statistically using 2-way ANOVA followed by Bonferroni's correction to determine the significance of differences between the groups (P ≤ 0.05). RESULTS: The FS of the denture base materials for CAD-CAM was significantly higher than that for the heat-activated group (P ≤ 0.05). The FS was significantly highest when microwave energy was used for the post-polymerization cycle. The FS values for all groups repaired with VLC resin were significantly lower than for the autopolymerization group (P ≤ 0.05). CONCLUSION: The flexural properties of denture base materials for CAD-CAM repaired using autopolymerizing acrylic resins can recover by 50-70%. Additional post-polymerization cycles for autopolymerizing repair resin can be suggested to improve the clinical service properties of repaired dentures.


Subject(s)
Dental Materials , Flexural Strength , Polymethyl Methacrylate , Denture Bases , Materials Testing , Acrylic Resins , Computer-Aided Design , Denture Repair , Surface Properties
13.
J Dent Res ; 103(5): 536-545, 2024 May.
Article in English | MEDLINE | ID: mdl-38549255

ABSTRACT

Dimethacrylate-based chemistries feature extensively as resin monomers in dental resin-based materials due to their distinguished overall performance. However, challenges endure, encompassing inadequate mechanical attributes, volumetric shrinkage, and estrogenicity. Herein, we first synthesized a novel resin monomer, 9-armed starburst polyurethane acrylate (NPUA), via the grafting-onto approach. Compared to the primary commercial dental monomer 2,2-bis [p-(2'-hydroxy-3'-methacryloxypropoxy) phenyl] propane (Bis-GMA) (with a viscosity of 1,174 ± 3 Pa·s and volumetric shrinkage of 4.7% ± 0.1%), the NPUA monomer achieves the lower viscosity (158 ± 1 Pa·s), volumetric shrinkage (2.5% ± 0.1%), and cytotoxicity (P < 0.05). The NPUA-based resins exhibit the higher flexural strength, flexural modulus, hardness, and hydrophobicity and lower volumetric shrinkage, water absorption, and solubility compared to the Bis-GMA (70 wt%)/TEGDMA (30 wt%) resins. The NPUA-based composites exhibit significantly higher flexural strength, flexural modulus, and hardness and lower volumetric shrinkage (171.4 ± 3.0 MPa, 12.6 ± 0.5 GPa, 2.0 ± 0.2 GPa, and 3.4% ± 0.2%, respectively) compared to the Bis-GMA group (120.3 ± 4.7 MPa, 9.4 ± 0.7 GPa, 1.5 ± 0.1 GPa, and 4.7% ± 0.2%, respectively; P < 0.05). This work presents a viable avenue for augmenting the physicochemical attributes of dental resins.


Subject(s)
Acrylic Resins , Materials Testing , Methacrylates , Polyurethanes , Polyurethanes/chemistry , Viscosity , Methacrylates/chemistry , Composite Resins/chemistry , Flexural Strength , Dental Materials/chemistry , Bisphenol A-Glycidyl Methacrylate/chemistry , Polymerization , Polymethacrylic Acids/chemistry , Hardness , Surface Properties
14.
Dent Mater ; 40(4): 756-763, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38429216

ABSTRACT

OBJECTIVE: To evaluate the influence of printing orientation on flexural strength (σf) and elastic modulus (E) of different 3D printing dental restorative resins. METHODS: Bar-shaped specimens (n = 20) were fabricated from two SLA-printed resins (FT- Formlabs Temporary, and FP- Formlabs Permanent) and two DLP-printed resins (DFT- Detax Freeprint Temp, and GCT- GC Temporary) using two building orientations (0º and 90º). The 3D-printed structures were aged (14 d) before submitted to three-point bending in 37ºC distilled water at a crosshead speed of 1.0 ± 0.3 mm/min until fracture to calculate the σf and the E values. The fractured surfaces were evaluated using stereomicroscopy and scanning electron microscopy (SEM) following fractography principles. Data were statistically analyzed using two-way ANOVA and Tukey post-hoc (α = 0.001). RESULTS: FP and FT showed significantly higher E values than DFT and GCT, irrespectively of printing orientation (p < 0.001). There was no statistical difference between the building orientations (0º and 90º) for the mean σf and E values for the resin materials evaluated. Fractographic characteristics were similar for the surface fracture from all the materials evaluated, showing typical brittle fracture behavior. SIGNIFICANCE: Printing orientation did not influence of flexural strength and elastic modulus values for the 3D-printed resin structures evaluated. Surface topography was mostly governed by the 3D printer type.


Subject(s)
Composite Resins , Dental Materials , Dental Materials/chemistry , Composite Resins/chemistry , Materials Testing , Flexural Strength , Printing, Three-Dimensional , Surface Properties
15.
Braz Dent J ; 35: e245728, 2024.
Article in English | MEDLINE | ID: mdl-38537023

ABSTRACT

This study analyzed the physical-chemical properties of bioactive ionomer materials. Cention N bioactive materials were evaluated chemically activated (CN) and light-cured (CN-LC), Equia Forte Fill (EQUI); conventional resin composite Filtek Z350 XT (Z350); resin glass ionomer cement Riva light Cure (RIVA) and flowable resin composite Filtek Bulk Fill Flow (BULK-F) were evaluated. Sixty specimens (n=10) were prepared for sorption (SR), solubility (SL), flexural strength (FS), shrinkage stress (SS), conversion degree (CD), microhardness (MI), and surface roughness (SR) tests. Non-cured and light-cured materials were assessed on FTIR. 30 human molar teeth were used in the bond strength test (BS). Data were subjected to ANOVA and post-hoc Tukey's test (5% of significance). EQUI showed more sorption in SR and no statistical difference from RIVA and CN-LC. CN group showed more solubility and EQUI presented less (p<0.05). BULK-F showed higher FS (MPa), without differences from CN and Z350, whereas EQUI presented the lowest FS not differing from RIVA. BULK-F and CN-LC showed more shrinkage stress differing from EQUI. CN-LC and CN showed higher CD differing from the other which showed no differences (p>0.05) between them. EQUI showed the highest hardness (p<0.05) in MI. There were no differences (p>0.05) in SR (µm). Z350 and BULK-F presented higher BS, whereas CN-LC showed the lowest, although not differing from EQUI and RIVA. Equia Forte's solubility and microhardness make it a good alternative as a restorative material. Cention N degree of conversion and flexural strength making it an esthetic option to amalgam.


Subject(s)
Composite Resins , Glass Ionomer Cements , Humans , Materials Testing , Composite Resins/chemistry , Dental Materials/chemistry , Flexural Strength , Hardness
16.
J Contemp Dent Pract ; 25(2): 191-195, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38514419

ABSTRACT

AIM: To evaluate and compare the fracture toughness and flexural strength of four different core build-up materials. MATERIALS AND METHODS: A total of 60 samples were divided into four groups (n = 15) group I: dual cure composite resin reinforced with zirconia particles (Luxacore Z), group II: light cure composite resin (Lumiglass DeepCure), group III: zirconia reinforced glass ionomer cement (GIC) (Zirconomer Improved), and group IV: chemically cure composite resin (Self Comp) respectively. All the core build-up materials were manipulated according to the manufacturer's instructions and poured into the mold. A universal testing machine applied a central load to the specimen in a 3-point bending mode. Fracture of the specimen was identified and the reading was recorded by the universal testing machine. The data were analyzed statistically using one-way analysis of variance (ANOVA) and then compared. RESULTS: Group I showed the highest flexural strength (48.65 MPa) among all the groups while group IV showed the lowest flexural strength (17.90 MPa). Group I showed the highest fracture toughness (99.12 MPa) among all the groups while group IV showed the lowest fracture toughness (36.41 MPa.cm-0.5). When mean flexural strength and fracture toughness values of all four groups were compared by using one-way ANOVA, the compared data was highly significant. CONCLUSION: Based on the findings of this study, dual cure composite resin was the material of choice in terms of flexural strength and fracture toughness for core build-up material followed by light cure composite resin. CLINICAL SIGNIFICANCE: The core buildup material serves to strengthen the tooth structure, allowing it to withstand the forces of chewing and preventing the risk of tooth fractures. This material is essential in restoring damaged or decayed teeth, as it provides a stable foundation for further dental work. By reinforcing the tooth structure, the core buildup material ensures that the tooth can function properly and remain healthy for years to come. How to cite this article: Nakade P, Thaore S, Bangar B, et al. Comparative Evaluation of Fracture Toughness and Flexural Strength of Four Different Core Build-up Materials: An In Vitro Study. J Contemp Dent Pract 2024;25(2):191-195.


Subject(s)
Flexural Strength , Fractures, Bone , Humans , Materials Testing , Composite Resins/chemistry , Zirconium
17.
Dent Mater ; 40(5): e1-e13, 2024 May.
Article in English | MEDLINE | ID: mdl-38438282

ABSTRACT

BACKGROUND: Functionally graded materials (FGM) with indistinct boundaries potentially eliminate the damaging stresses occurring at the interfaces. FGM applications in dental ceramics have enhanced their fatigue resistance and interfacial toughness. OBJECTIVES: This scoping review aims to map graded designs in dental ceramics, distinguish their methodological approaches with their material characteristics and properties, and understand the factors affecting the outcomes of each of the graded approaches. METHODS: A systematic electronic search was performed with the databases MEDLINE (PubMed), Scopus, Cochrane Library, EBSCO, and Google Scholar along with a manual search. RESULTS: About 2675 articles were initially found from all the searches with no date restriction till July 2023. After rejecting duplicates and based on exclusion criteria, about 52 articles were included. SIGNIFICANCE: Methodological approaches in grading such as glass-infiltration and silica-infiltration have been investigated on pre-sintered zirconia. The type of infiltration and the method of infiltrate application significantly influenced the phase transformation of zirconia, its microstructure, surface hardness, fracture toughness, flexural strength, wear, and fatigue strength of graded dental zirconia. Interlayers were accommodated between metal-ceramic and veneer-core all-ceramic layers. Fractions of zirconia-porcelain and alumina-porcelain showed high bending strength and better stress distribution. The results of finite element analysis studies predicted that using 10-layered graded layers reduced the stresses at the crown-cement-dentin interface.


Subject(s)
Ceramics , Materials Testing , Ceramics/chemistry , Zirconium/chemistry , Surface Properties , Dental Materials/chemistry , Humans , Dental Stress Analysis , Hardness , Dental Porcelain/chemistry , Flexural Strength
18.
Int J Nanomedicine ; 19: 1273-1285, 2024.
Article in English | MEDLINE | ID: mdl-38348176

ABSTRACT

Purpose: To investigate the inhibition of Streptococcus mutans (S.mutans) and its biofilm by AgBr-nanoparticles (NP) @CTMAB (cetyltrimethyl-ammonium bromide) and evaluate the changes in Polymethyl methacrylate (PMMA)'s surface roughness (Ra), microhardness, and flexural strength during prolonged immersion in AgBr-NP@CTMAB for application in the denture cleaning industry. Patients and Methods: The antibacterial activity of AgBr-NP@CTMAB against S.mutans was measured colony formation assay, OD600 and laser confocal microscopy. Changes in the specimens' values for surface roughness, microhardness, and flexural strength (MPa) were measured after immersion solutions for 180 or 360 days. Results: The AgBr-NP@CTMAB solution exhibited a robust antibacterial effect on planktonic S. mutans, with a minimum bactericidal concentration of 5 µg/mL. The 10 µg/mL AgBr-NP@CTMAB solution efficiently inhibited S. mutans biofilm formation. (2) No significant difference in surface roughness after immersion in AgBr-NP@CTMAB (10 µg/mL and 20 µg/mL) comparing with distilled water (P > 0.05) and Polident had significantly higher than distilled water (P < 0.05). There was a significant decrease in the surface hardness of the PMMA specimens that were immersed in the Polident compared with those in distilled water (P < 0.05). While, no significant differences in surface hardness after immersion in the AgBr-NP@CTMAB (P > 0.05). The result of flexural strength suggested that there was no statistically significant difference (P < 0.05) between AgBr-NP@CTMAB as well as Polident and water. Conclusion: AgBrNP@CTMAB can efficiently inhibit the growth of plankton S.mutans and biofilm formation, without affecting the flexural strength, microhardness, or surface roughness of PMMA. Therefore, AgBrNP@CTMAB holds promise as a new denture cleaning agent.


Subject(s)
Borates , Nanoparticles , Polymethyl Methacrylate , Sulfates , Hardness , Flexural Strength , Streptococcus mutans , Denture Bases , Water , Anti-Bacterial Agents/pharmacology , Surface Properties , Materials Testing
19.
Int J Prosthodont ; 37(1): 72-79, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38381986

ABSTRACT

PURPOSE: To investigate the biaxial flexural strength of zirconia materials with different translucency before and after aging procedures and to evaluate the effects of aging on hardness and surface characteristics. MATERIALS AND METHODS: A total of 90 disc-shaped specimens (n = 30 each) were prepared from translucent (Upcera-ST, Upcera Dental), high translucent (Katana HT, Kuraray Noritake), and ultra high translucent (Katana UTML, Kuraray Noritake) zirconia materials to a ø.16 ±1.2 mm thickness. The different translucency discs were then divided into three subgroups; one group was subjected to aging in a chewing simulator (n = 10), one group was aged with thermocycling (n = 10), and one was a control group (n = 10). Biaxial flexural strength, Vickers hardness, and surface characteristics were examined for all discs. The data were analyzed using the Shapiro-Wilk (P = .05), Mann-Whitney U, and Kruskal-Wallis H tests. Fracture strength was determined using biaxial bending strength tests, and Weibull analysis was used to analyze the resulting data. RESULTS: A statistically significant difference was found among zirconia materials with different translucency in terms of fracture strength. On average, fracture strength was highest in the Upcera ST group (1,932.87 MPa) and lowest in the Katana UTML group (1,073.6 MPa; P = .001). The results of Weibull analysis showed a statistically similar distribution for all groups. CONCLUSIONS: Aging procedures did not cause significant differences in fracture strength and hardness. The fracture strength of the zirconia materials with different translucency was considered acceptable for intraoral use.


Subject(s)
Dental Materials , Flexural Strength , Materials Testing , Zirconium , Surface Properties , Ceramics , Yttrium
20.
J Dent ; 142: 104865, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38311017

ABSTRACT

OBJECTIVES: To evaluate the fracture strength and linear elongation at break of three-units fixed partial dentures (FPDs) fabricated with traditional and new materials for fixed prosthodontics before and after ageing. METHODS: Sixty models of three-units FPDs were fabricated and cemented onto a Co-Cr model simulating the replacement of a maxillary second premolar. The samples were randomly divided into 3 groups: metal-ceramic (MCR), graphene-doped polymethylmethacrylate (PMMA-GR) and polymethylmethacrylate (PMMA). Half of the samples were directly subjected to fracture test, while the remaining half underwent an ageing process and then a fracture loading test using an electrodynamic testing machine. Fracture load and elongation at break values were taken and statistically analysed. RESULTS: Significant differences were detected between the different materials (p<0.05). All groups showed a reduction of the fracture load and elongation at break values after ageing, but not statistically significant, except for PMMA group (p = 2.012e-19) (p = 3.8e-11). CONCLUSIONS: MCR and PMMA-GR three-units FPDs showed higher fracture strength and lower elongation at break compared to PMMA. MCR and PMMA-GR had higher resistance to ageing processes compared to PMMA. CLINICAL SIGNIFICANCE: PMMA-GR could be considered a material for long-term provisional restorations as its mechanical behaviour and ageing resistance are more like MCR than PMMA.


Subject(s)
Flexural Strength , Graphite , Polymethyl Methacrylate , Materials Testing , Ceramics , Denture, Partial, Fixed , Dental Restoration Failure , Dental Stress Analysis , Dental Porcelain
SELECTION OF CITATIONS
SEARCH DETAIL
...