Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 296
Filter
1.
J Oncol Pharm Pract ; 30(1): 9-14, 2024 Jan.
Article in English | MEDLINE | ID: mdl-36916178

ABSTRACT

INTRODUCTION: Antineoplastic drugs (ADs) are commonly used pharmaceuticals for anticancer treatments. It has previously been shown that the external surface of drug vials frequently is contaminated with ADs. More than a decade ago methods to prevent occupational exposure were introduced by using plastic coverage of the glass vials or packing vials in a secondary plastic container. The aim of the pilot study was to determine contamination levels of ADs on different parts of AD packaging of two different commercially available drug vials on the Swedish market and to investigate the occurrence of cross contamination of ADs. METHODS: Packagings of gemcitabine (GEM) and 5-fluorouracil (5-FU) were tested by wipe sampling. Five ADs; GEM, 5-FU, cyclophosphamide (CP), ifosfamide and etoposide were quantified using liquid chromatography mass spectrometry. RESULTS: AD contaminations were detected in 69% and 60% of the GEM and 5-FU packaging samples. Highest levels, up to approximately 5 µg/sample, were observed on the glass vials. The protective shrink-wrap of 5-FU vials and the plastic container of GEM were contaminated with low levels of 5-FU and GEM, respectively, and furthermore the 5-FU vials with shrink-wrap were cross-contaminated with GEM. Cross-contamination of CP and GEM was detected on 5-FU vials with plastic shrink-wrap removed. CONCLUSIONS: External contamination of ADs are still present at primary drug packagings on the Swedish market. Protection of AD vials by plastic shrink-wrap or a secondary plastic container does not remove the external contamination levels completely. The presence of cross contamination of ADs on drug packagings was also observed.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Humans , Gemcitabine , Fluorouracil/analysis , Pilot Projects , Drug Packaging , Equipment Contamination/prevention & control , Antineoplastic Agents/analysis , Cyclophosphamide/analysis , Occupational Exposure/prevention & control , Occupational Exposure/analysis , Environmental Monitoring/methods , Drug Contamination/prevention & control
2.
Front Public Health ; 11: 1235496, 2023.
Article in English | MEDLINE | ID: mdl-37780438

ABSTRACT

Introduction: The exposures to hazardous antineoplastic drugs (AD) represent serious risks for health care personnel but the exposure limits are not commonly established because of the no-threshold effects (genotoxic action, carcinogenicity) of many ADs. In this study, we discussed and derived practically applicable technical guidance values (TGV) suitable for management of AD risks. Methods: The long-term monitoring of surface contamination by eight ADs was performed in pharmacies and hospitals in the Czech Republic and Slovak Republic in 2008-2021; in total 2,223 unique samples were collected repeatedly in 48 facilities. AD contamination was studied by LC-MS/MS for cyclophosphamide, ifosfamide, methotrexate, irinotecan, paclitaxel, 5-fluorouracil and gemcitabine and by ICP-MS for total Pt as a marker of platinum-based ADs. Results: The study highlighted importance of exposure biomarkers like 5-fluorouracil and especially carcinogenic and persistent cyclophosphamide, which should be by default included in monitoring along with other ADs. Highly contaminated spots like interiors of laminar biological safety cabinets represent a specific issue, where monitoring of contamination does not bring much added value, and prevention of staff and separated cleaning procedures should be priority. Rooms and surfaces in health care facilities that should be virtually free of ADs (e.g., offices, kitchenettes, daily rooms) were contaminated with lower frequency and concentrations but any contamination in these areas should be carefully examined. Discussion and conclusions: For all other working places, i.e., majority of areas in pharmacies and hospitals, where ADs are being prepared, packaged, stored, transported, or administered to patients, the study proposes a generic TGV of 100 pg/cm2. The analysis of long-term monitoring data of multiple ADs showed that the exceedance of one TGV can serve as an indicator and trigger for improvement of working practices contributing thus to minimizing of unintended exposures and creating a safe work environment.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Pharmacies , Humans , Slovakia , Chromatography, Liquid , Czech Republic , Occupational Exposure/analysis , Tandem Mass Spectrometry , Cyclophosphamide/analysis , Fluorouracil/analysis , Hospitals
3.
Int Arch Occup Environ Health ; 96(5): 675-683, 2023 07.
Article in English | MEDLINE | ID: mdl-36877242

ABSTRACT

PURPOSE: The handling of antineoplastic drugs represents an occupational health risk for employees in pharmacies. To minimize exposure and to evaluate cleaning efficacy, wipe sampling was used to analyze antineoplastic drugs on surfaces. In 2009, guidance values were suggested to facilitate the interpretation of results, leading to a decrease in surface contamination. The goal of this follow-up was to evaluate the time trend of surface contamination, to identify critical antineoplastic drugs and sampling locations and to reassess guidance values. METHODS: Platinum, 5-fluorouracil, cyclophosphamide, ifosfamide, gemcitabine, methotrexate, docetaxel and paclitaxel were analyzed in more than 17,000 wipe samples from 2000 to 2021. Statistical analysis was performed to describe and interpret the data. RESULTS: Surface contaminations were generally relatively low. The median concentration for most antineoplastic drugs was below the limit of detection except for platinum (0.3 pg/cm2). Only platinum and 5-fluorouracil showed decreasing levels over time. Most exceedances of guidance values were observed for platinum (26.9%), cyclophosphamide (18.5%) and gemcitabine (16.6%). The most affected wipe sampling locations were isolators (24.4%), storage areas (17.6%) and laminar flow hoods (16.6%). However, areas with no direct contact to antineoplastic drugs were also frequently contaminated (8.9%). CONCLUSION: Overall, the surface contaminations with antineoplastic drugs continue to decrease or were generally at a low level. Therefore, we adjusted guidance values according to the available data. The identification of critical sampling locations may help pharmacies to further improve cleaning procedure and reduce the risk of occupational exposure to antineoplastic drugs.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Pharmacies , Humans , Platinum/analysis , Environmental Monitoring/methods , Equipment Contamination , Antineoplastic Agents/analysis , Fluorouracil/analysis , Cyclophosphamide/analysis , Gemcitabine , Occupational Exposure/analysis
4.
Occup Environ Med ; 80(3): 146-153, 2023 03.
Article in English | MEDLINE | ID: mdl-36717254

ABSTRACT

OBJECTIVES: This study aimed to monitor the contamination by antineoplastic drugs on work surfaces in a compounding unit 4 years after its implementation. METHODS: This descriptive study was done in a unit performing on average 45 000 preparations per year. Surface sampling points (N=23) were monitored monthly in the frame of routine activity from the opening of an anticancer drug compounding unit. Contamination with nine antineoplastic drugs (cyclophosphamide, ifosfamide, dacarbazine, 5-fluorouracil, methotrexate, gemcitabine, cytarabine, irinotecan and doxorubicin) was assessed on wipes with a local liquid chromatography coupled with a tandem mass spectrometer analysis. The contamination rate (CR, %) was prospectively monitored every month during the entire study period. The occurrence of critical incidents was also registered. The effect of each safety measure implemented during this period was also analysed. RESULTS: Based on the 1104 samples collected between March 2016 and March 2020, the CR was 18.5%. If three different critical incidents among a vial breakage that occurred were individually considered, this CR was slightly lower than that in the literature. Eight months after opening and taking different corrective actions, the overall CR dropped from 42.39% to 11.52% (p<0.001). Contamination was limited to the area that includes the compounding room and, more precisely, the welder and the QC-Prep+ sampling points. CONCLUSIONS: From the beginning of the study and from month to month, surface contamination was limited to the nearest sampling points to the compounding unit. This 4-year monitoring study allowed us to determine the intravenous conventional antineoplastic drugs and sampling points to be focused on.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Humans , Follow-Up Studies , Antineoplastic Agents/analysis , Antineoplastic Agents/chemistry , Cyclophosphamide/adverse effects , Cyclophosphamide/analysis , Ifosfamide/analysis , Fluorouracil/analysis , Occupational Exposure/adverse effects , Occupational Exposure/analysis , Environmental Monitoring/methods
5.
Ann Work Expo Health ; 67(2): 241-251, 2023 02 13.
Article in English | MEDLINE | ID: mdl-36416483

ABSTRACT

The exposure of healthcare workers to antineoplastic drugs in hospitals has been recognized to be harmful. To minimize the risk of exposure, the removal of these drugs from work environments, such as compounding facilities, has been recommended. In our previous paper, the degradation and inactivation efficacy of ozone water, which is being introduced into Japanese hospitals as a chemical decontamination agent, was reported for its effects on typical antineoplastic drugs (gemcitabine, irinotecan, paclitaxel). This article aims to further investigate the efficacy of ozone water for eight antineoplastic drugs to clarify its application limitations. A small amount (medicinal ingredient: typically ca. 1.5 µmol) of formulation containing 5-fluorouracil, pemetrexed, cisplatin, oxaliplatin, cyclophosphamide, ifosfamide, doxorubicin, or docetaxel was mixed with 50 mL of ozone water (~8 mg/L), and the resulting solutions were analyzed by high-performance liquid chromatography over time to observe the degradation. Consequently, the ozonation was overall effective for the degradation of the drugs, however this varied depending on the chemical structures of the drugs and additives in their formulations. In addition, after the parent drugs were completely degraded by the ozonation, the degradation mixtures were subjected to 1H nuclear magnetic resonance spectroscopy and evaluated for mutagenicity against Salmonella typhimurium strains and cytotoxicity against human cancer cells. The degradation mixtures of cisplatin and ifosfamide were mutagenic while those of the other drugs were non-mutagenic. Further, the ozonation resulted in clear decreases of cytotoxicity for 5-fluorouracil, oxaliplatin, and doxorubicin, but increases of cytotoxicity for pemetrexed, cisplatin, cyclophosphamide, and ifosfamide. These results suggest that the ozone water should be restrictedly used according to the situation of contamination in clinical settings because the ozonation enhances toxicity depending on the drug even if degradation is achieved.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Ozone , Humans , Ifosfamide/analysis , Cisplatin/analysis , Oxaliplatin , Pemetrexed/analysis , Ozone/analysis , Ozone/chemistry , Water/analysis , Decontamination/methods , Occupational Exposure/analysis , Antineoplastic Agents/therapeutic use , Antineoplastic Agents/analysis , Cyclophosphamide/analysis , Fluorouracil/analysis , Doxorubicin/analysis , Mutagens
6.
J Vasc Access ; 24(4): 653-659, 2023 Jul.
Article in English | MEDLINE | ID: mdl-34538108

ABSTRACT

BACKGROUND: Occupational exposure to cytotoxic drugs can lead to significant health problems. This study was designed to evaluate the risk of 5-fluorouracil (5-FU) contamination for nurses when disconnecting the infusion line of an elastomeric pump from a non-coring needle, by comparing three configurations: the first one using standard Male and Female Luer lock (Group 1), the second one using a needle-free connector (NFC) and a Male Luer lock (Group 2) and the third one using a closed-system transfer device (CSTD), Qimono® (Group 3). METHODS: In this in vitro study, 10 elastomeric pumps for each of the three groups were filled with 5-FU and a tissue mimicking the patient's arm was placed below the connection between the infusion line and the tubing of non-coring needle. After 48 h of infusion, disconnection was performed by a nurse with a wipe soaked in a mix of chlorhexidine and isopropyl alcohol in order to mimic care practices. For each pump, the tissue, the pair of gloves and the wipes used during the disconnection were collected for analysis. RESULTS: Median level of overall 5-FU contamination (gloves + wipes + tissues) in group 3 was significantly lower than in group 1 (p = 0.018) and group 2 (p = 0.036). There was no difference between groups 1 and 2. Results per sample type showed no difference in contamination between the three configurations for the gloves as well as for the tissues. Concerning the wipes, the lowest contamination was observed in group 3, representing a mean reduction of 61% compared to group 1 and a mean reduction of 43% compared to group 2. CONCLUSION: The use of Qimono® appears to significantly reduce 5-FU contamination when disconnecting infusion lines of an elastomeric pump unlike NFC and standard Luer lock.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Male , Female , Humans , Fluorouracil/adverse effects , Fluorouracil/analysis , Perfusion
7.
Article in English | MEDLINE | ID: mdl-35886450

ABSTRACT

In the present study, surface contamination where antineoplastic drugs (ADs) are present was investigated, as occupational exposure risk is still an open debate. Despite recommendations and safety standard procedures being in place in health care settings, quantifiable levels of ADs are being reported in the recent literature. Thus, a survey monitoring program was conducted over five years (2016-2021) in nine Italian hospitals. The repeated surveys produced 8288 data points that have been grouped according to the main hospital settings, such as pharmacy areas and patient care units. Based on the most often prepared ADs, the investigated drugs were cyclophosphamide (CP), gemcitabine (GEM), 5-fluorouracil (5-FU), and platinum compounds (Pt). Patient care units had a frequency of positive wipe samples (59%) higher than pharmacies (44%). Conversely, pharmacies had a frequency of positive pad samples higher (24%) than patient care units (10%). Moreover, by statistical analysis, pad samples had a significantly higher risk of contamination in pharmacy areas than in patient care units. In this study, the 75th and the 90th percentiles of the contamination levels were obtained. The 90th percentile was chosen to describe a suitable benchmark that compares results obtained by the present research with those previously reported in the literature. Based upon surface contamination loads, our data showed that 5-FU had the highest concentration values, but the lowest frequency of positive samples. In pharmacy areas, the 90th percentile of 5-FU data distribution was less than 0.346 ng/cm2 and less than 0.443 ng/cm2 in patient care units. AD levels are higher than those reported for health care settings in other European countries yet trends of contamination in Italy have shown to decrease over time.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Antineoplastic Agents/analysis , Environmental Monitoring/methods , Equipment Contamination , Fluorouracil/analysis , Hospitals , Humans , Occupational Exposure/analysis
8.
Chemosphere ; 296: 134007, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35181426

ABSTRACT

Nowadays, the entry of organic compounds into water resources is one of the leading global concerns due to the lack of water resources and rapid population growth. In this research, anodic oxidation (AO) method was used to remove 5-fluorouracil (5-FU) from aqueous solutions via Ni/RuO2 and Ti/IrO2-TiO2-RuO2 electrodes as cathode and anode, respectively. For this purpose, the characterization analysis of the electrodes, including X-ray diffraction, scanning electron microscopy, energy dispersive X-ray, and atomic force microscopy were performed. The electrochemical performance of the anode was investigated via cyclic voltammetry analysis. Then, the effect of operational variables, including applied current (mA), initial pH of the solution, initial 5-FU concentration (mg/L), and process time (min) on the 5-FU removal efficiency under the AO process was evaluated via artificial neural network (ANN) modeling. The results revealed that the maximum 5-FU removal efficiency was 96.96%. The applied current intensity, pH, initial 5-FU concentration, and process time were 300 mA, 5, 20 mg/L, and 140 min, respectively. Moreover, the investigation of 5-FU removal by-products and mineralization efficiency of the AO process was carried out via gas chromatography-mass spectrometry and total organic carbon analysis, respectively. The total organic carbon mineralization efficiency was 84.80% after 6 h of reaction time. The reusability and stability of the Ti/IrO2-TiO2-RuO2 anode on 5-FU removal efficiency were measured and showed an approximately 5% decay in 5-FU removal efficiency after eight consecutive runs. The overall results and analysis confirmed this method is capable of removing 5-FU through Ti/IrO2-TiO2-RuO2 anode and Ni/RuO2 cathode from aqueous medium.


Subject(s)
Wastewater , Water Pollutants, Chemical , Carbon , Electrodes , Fluorouracil/analysis , Oxidation-Reduction , Oxides/chemistry , Pharmaceutical Preparations , Titanium/chemistry , Wastewater/chemistry , Water/analysis , Water Pollutants, Chemical/analysis
9.
J Occup Environ Hyg ; 19(1): 50-66, 2022 01.
Article in English | MEDLINE | ID: mdl-34723774

ABSTRACT

The main objective was to develop a wipe sampling test to measure surface contamination of the most frequently used antineoplastic drugs (ADs) in Swedish healthcare and, furthermore, to develop an analysis method sensitive enough to assess low levels of contamination. Two wipe sampling tests with separate sample processing methods assessing (i) cyclophosphamide (CP), ifosfamide (IF), 5-fluorouracil (5-FU), etoposide (ETO), gemcitabine (GEM) and cytarabine (CYT) (Wipe Test 1); and (ii) GEM, CYT and methotrexate (MTX) (Wipe Test 2), respectively, were developed by optimization of absorption and extraction efficiencies using different wipe tissue materials, tissue wetting solution, and extraction solvents. A fast liquid chromatography tandem mass spectrometry method was developed for simultaneous detection of the studied ADs. The limit of quantification for the method was between 0.04 to 2.4 ng/wipe sample (0.10 to 6.1 pg/cm2 for an area of 400 cm2) and at 50 ng/sample the within-day precision was between 1.3 and 15%, and the accuracy between 102 and 127%. Wipe Test 1 was applied in an assessment of cleaning efficiency of five different cleaning solutions (formic acid, water, sodium hydroxide, ethanol, and sodium dodecyl sulfate (SDS) for removal of ADs from surfaces made of stainless steel or plastic. For CP, IF, 5-FU, GEM, and CYT 92% of the AD were removed regardless of surface and cleaning solution. In conclusion, a user-friendly assessment method to measure low levels of seven ADs in the work environment was developed and validated. Assessment of the decontamination efficiency of cleaning solutions concerning removal of ADs from stainless steel showed that efficiencies differed depending on the AD with water being the least effective cleaning agent. The results suggests that a combination of different cleaning agents including detergent and a solution with an organic component would be optimal to efficiently remove the measured ADs from surfaces in the workplace.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Antineoplastic Agents/analysis , Chromatography, Liquid , Cyclophosphamide/analysis , Fluorouracil/analysis , Ifosfamide/analysis , Occupational Exposure/analysis , Specimen Handling , Stainless Steel/analysis , Tandem Mass Spectrometry/methods , Water
10.
J Oncol Pharm Pract ; 28(7): 1487-1498, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34162245

ABSTRACT

OBJECTIVES: The aims of the study were to evaluate the external contamination of hazardous drug vials used in Chinese hospitals and to compare environmental contamination generated by a robotic intelligent dispensing system (WEINAS) and a manual compounding procedure using a biological safety cabinet (BSC). METHODS: Cyclophosphamide, fluorouracil, and gemcitabine were selected as the representative hazardous drugs to monitor surface contamination of vials. In the comparative analysis of environmental contamination from manual and robotic compounding, wipe samples were taken from infusion bags, gloves, and the different locations of the BSC and the WEINAS robotic system. In this study, high-performance liquid chromatography coupled with double mass spectrometer (HPLC-MS/MS) was employed for sample analysis. RESULTS: (1) External contamination was measured on vials of all three hazardous drugs. The contamination detected on fluorouracil vials was the highest with an average amount up to 904.33 ng/vial, followed by cyclophosphamide (43.51 ng/vial), and gemcitabine (unprotected vials of 5.92 ng/vial, protected vials of 0.66 ng/vial); (2) overall, the environmental contamination induced by WEINAS robotic compounding was significantly reduced compared to that by manual compounding inside the BSC. Particularly, compared with manual compounding, the surface contamination on the infusion bags during robotic compounding was nearly nine times lower for cyclophosphamide (10.62 ng/cm2 vs 90.43 ng/cm2), two times lower for fluorouracil (3.47 vs 7.52 ng/cm2), and more than 23 times lower for gemcitabine (2.61 ng/cm2 vs 62.28 ng/cm2). CONCLUSIONS: The external contamination occurred extensively on some hazardous drug vials that commonly used in Chinese hospitals. Comparison analysis for both compounding procedures revealed that robotic compounding can remarkably reduce environmental contamination.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Robotic Surgical Procedures , Robotics , Antineoplastic Agents/analysis , China , Cyclophosphamide/analysis , Drug Compounding , Environmental Monitoring/methods , Equipment Contamination/prevention & control , Fluorouracil/analysis , Hospitals , Humans , Occupational Exposure/analysis , Occupational Exposure/prevention & control , Robotics/methods , Tandem Mass Spectrometry
11.
J Oncol Pharm Pract ; 28(7): 1508-1515, 2022 Oct.
Article in English | MEDLINE | ID: mdl-34229499

ABSTRACT

PURPOSE: The purpose of this study was to test the efficacy of ChemfortTM, an air filtration closed-system drug transfer device to prevent release of chemotherapy drug vapors and aerosols under extreme conditions. The air cleaning system is based on the adsorption of drug vapors by an activated carbon filter in the Vial Adaptor before the air is released out of the drug vial. The functionality of the carbon filter was also tested at the end of device's shelf life, and after a contact period with drug vapors for 7 days. Cyclophosphamide and 5-fluorouracil were the chemotherapy drugs tested. METHODS: The Vial Adaptor was attached to a drug vial and both were placed in a glass vessel. A needle was punctured through the vessel stopper and the Vial Adaptor septum to allow nitrogen gas to flow into the vial and to exit the vial via the air filter into the glass vessel which was connected to a cold trap. Potential contaminated surfaces in the trap system were wiped or rinsed to collect the escaped drug. Samples were analyzed using liquid chromatography tandem mass spectrometry. RESULTS: Cyclophosphamide and 5-fluorouracil were detected on most surfaces inside the trap system for all Vial Adaptors without an activated carbon filter. Contamination did not differ between the Vial Adaptors with and without membrane filter indicating no effect of the membrane filter. The results show no release of either drug for the Vial Adaptors with an activated carbon filter even after 3 years of simulated aging and 7 days of exposure to drug vapors. CONCLUSIONS: Validation of air cleaning CSTDs is important to secure vapor and aerosol containment of chemotherapy and other hazardous drugs. The presented test method has proven to be appropriate for the validation of ChemfortTM Vial Adaptors. No release of cyclophosphamide and 5- fluorouracil was found even for Vial Adaptors after 3 years of simulated aging and 7 days of exposure to drug vapors.


Subject(s)
Charcoal , Occupational Exposure , Charcoal/analysis , Cyclophosphamide/analysis , Drug Contamination , Fluorouracil/analysis , Humans , Occupational Exposure/analysis , Protective Devices
12.
Environ Sci Pollut Res Int ; 29(18): 26810-26819, 2022 Apr.
Article in English | MEDLINE | ID: mdl-34855176

ABSTRACT

The consumption of hazardous antineoplastic drugs (ADs) used in anticancer chemotherapies is steadily increasing representing thus risks to both human health and the environment. Hospitals may serve as a contamination source, and pharmacists preparing the antineoplastic drugs (ADs) as well as nurses administering chemotherapy and caring for oncology patients are among the healthcare professionals being highly exposed. Here, we present the results of systematic monitoring (2018-2020) of surface contamination by 13 ADs in the pharmacies and hospitals in the Czech Republic (CZ; large-scale monitoring, 20 workplaces) and Slovak Republic (SK; pilot study at 4 workplaces). The study evaluated contamination by three commonly monitored ADs, i.e., 5-fluorouracil (FU), cyclophosphamide (CP), and platinum (total Pt representing cis-, carbo-, and oxaliplatin) together with ten less explored ADs, i.e., gemcitabine (GEM), ifosfamide (IF), paclitaxel (PX), irinotecan (IRI), docetaxel (DOC), methotrexate (MET), etoposide (ETOP), capecitabine (CAP), imatinib (IMAT), and doxorubicin (DOX). Floors and desktop surfaces in hospitals (chemotherapy application rooms, nurse working areas) were found to be more contaminated, namely with CP and Pt, in both countries when compared to pharmacies. Comparison between the countries showed that hospital surfaces in SK are generally more contaminated (e.g., CP median was 20 times higher in SK), while some pharmacy areas in the CZ were more contamined in comparison with SK. The newly studied ADs were detected at lower concentrations in comparison to FU, CP, and Pt, but some markers (GEM, IF, PX, and IRI) were frequently observed, and adding these compounds to routine monitoring is recommended.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Pharmacies , Antineoplastic Agents/analysis , Cyclophosphamide/analysis , Czech Republic , Environmental Monitoring/methods , Equipment Contamination , Fluorouracil/analysis , Hospitals , Humans , Ifosfamide/analysis , Occupational Exposure/analysis , Pilot Projects , Slovakia
13.
Int Arch Occup Environ Health ; 94(8): 1877-1888, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34410477

ABSTRACT

OBJECTIVE: Occupational exposure to antineoplastic drugs (ANPs) occurs mainly through dermal contact. Our study was set up to assess the potential exposure of hospital sanitation (HS) personnel, for whom almost no data are available, through contamination of surfaces they regularly touch. METHODS: In the oncology departments of two hospitals around Montreal, surface wipe samples of 120-2000 cm2 were taken at 10 sites cleaned by the HS personnel and five other sites frequently touched by nursing and pharmacy personnel. A few hand wipe samples were collected to explore skin contamination. Wipes were analyzed by ultra-performance liquid chromatography tandem-mass spectrometry for 10 ANPs. RESULTS: Overall, 60.9% of 212 surface samples presented at least one ANP above the limits of detection (LOD). Cyclophosphamide and gemcitabine were most often detected (52% and 31% of samples respectively), followed by 5-fluorouracil and irinotecan (15% each). Highest concentrations of five ANPs were found in outpatient clinics on toilet floors (5-fluorouracil, 49 ng/cm2; irinotecan, 3.6 ng/cm2), a perfusion pump (cyclophosphamide, 19.6 ng/cm2) and on a cytotoxic waste bin cover (gemcitabine, 4.97 ng/cm2). Floors in patient rooms had highest levels of cytarabine (0.12 ng/cm2) and methotrexate (6.38 ng/cm2). Hand wipes were positive for two of 12 samples taken on HS personnel, seven of 18 samples on nurses, and two of 14 samples on pharmacy personnel. CONCLUSIONS: A notable proportion of surfaces showed measurable levels of ANPs, with highest concentrations found on surfaces cleaned by HS personnel, who would benefit from appropriate preventive training. As potential sources of worker exposure, several hospital surfaces need to be regularly monitored to evaluate environmental contamination and efficacy of cleaning.


Subject(s)
Antineoplastic Agents/analysis , Occupational Exposure/analysis , Personnel, Hospital , Adult , Cyclophosphamide/analysis , Cytarabine/analysis , Deoxycytidine/analogs & derivatives , Deoxycytidine/analysis , Docetaxel/analysis , Female , Fluorouracil/analysis , Hand , Hospitals , Humans , Ifosfamide/analysis , Irinotecan/analysis , Male , Methotrexate/analysis , Middle Aged , Paclitaxel/analysis , Sanitation , Skin/chemistry , Vinorelbine/analysis , Gemcitabine
14.
Anal Bioanal Chem ; 413(9): 2587-2596, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33624127

ABSTRACT

The drugs used for treatment during chemotherapy are manufactured individually for each patient in specialised pharmacies. Thorough quality control to confirm the identity of the delivered active pharmaceutical ingredient and the final concentration of the prepared application solution is not standardized yet except for optical or gravimetric testing. However, solution stability problems, counterfeit drugs, and erroneous or deliberate underdosage may occur and negatively influence the quality of the product and could cause severe health risks for the patient. To take a step towards analytical quality control, an on-site analytical instrument using Raman and UV absorption spectroscopy was employed and the results were compared to high-performance liquid chromatography coupled to diode array detection. Within the scope of the technology evaluation, the uncertainty of measurement was determined for the analysis of the five frequently used cytostatic drugs 5-fluorouracil, cyclophosphamide, gemcitabine, irinotecan and paclitaxel. The Raman/UV technique (2.0-3.2% uncertainty of measurement; level of confidence: 95%) achieves a combined uncertainty of measurement comparable to HPLC-DAD (1.7-3.2% uncertainty of measurement; level of confidence: 95%) for the substances 5-fluorouracil, cyclophosphamide and gemcitabine. However, the uncertainty of measurement for the substances irinotecan and paclitaxel is three times higher when the Raman/UV technique is used. This is due to the fact that the Raman/UV technique analyses the undiluted sample; therefore, the sample has a higher viscosity and tendency to foam. Out of 136 patient-specific preparations analysed within this study, 96% had a deviation of less than 10% from the target content.


Subject(s)
Antineoplastic Agents/analysis , Cytostatic Agents/analysis , Chromatography, High Pressure Liquid/methods , Cyclophosphamide/analysis , Deoxycytidine/analogs & derivatives , Deoxycytidine/analysis , Drug Compounding , Drug Stability , Drug Storage , Fluorouracil/analysis , Irinotecan/analysis , Quality Control , Spectrophotometry, Ultraviolet/methods , Spectrum Analysis, Raman/methods , Workflow , Gemcitabine
15.
J Occup Environ Hyg ; 18(2): 43-50, 2021 02.
Article in English | MEDLINE | ID: mdl-33357045

ABSTRACT

The main objective was to determine the decontamination efficacy of quaternary ammonium, 0.1% sodium hypochlorite, and water after deliberate contamination with four antineoplastics (ifosfamide, 5-fluorouracil, irinotecan, methotrexate). A stainless-steel surface was deliberately contaminated with ifosfamide (15 µg), 5-fluorouracil (10 µg), irinotecan (1 µg), and methotrexate (1 µg). First, a single decontamination step with either water, quaternary ammonium, or 0.1% sodium hypochlorite was tested. Then, the effect of up to four successive decontamination steps with either quaternary ammonium or 0.1% sodium hypochlorite was tested. Commercial wipes consisting of two layers of non-woven microfibers with an inner layer of highly absorbent viscose fibers were used. Triplicate surface samples were obtained and tested by ultra-performance liquid chromatography tandem mass spectrometry. The limits of detection were 0.004 ng/cm2 for ifosfamide, 0.040 ng/cm2 for 5-fluorouracil, 0.003 ng/cm2 for irinotecan, and 0.002 ng/cm2 for methotrexate. After a single decontamination step, the 0.1% sodium hypochlorite eliminated 100% of contamination with 5-fluorouracil, irinotecan, and methotrexate and 99.6 ± 0.5% of ifosfamide contamination. Quaternary ammonium and water also removed 100% of the 5-fluorouracil, and 99.5% to 99.9% of the other three antineoplastics. For ifosfamide, irinotecan, and methotrexate, the decontamination efficacy increased with successive decontamination steps with quaternary ammonium. 5-fluorouracil was undetectable after a single decontamination step. Methotrexate was the only drug for which decontamination efficacy was less than 100% after four decontamination steps. 100% decontamination efficacy was achieved from the decontamination step with 0.1% sodium hypochlorite for 5-fluorouracil, irinotecan, and methotrexate. For ifosfamide, 100% efficacy was achieved only after the third decontamination step. It was possible to make all traces of antineoplastic undetectable after deliberate contamination with 5-fluorouracil, irinotecan, and methotrexate with a 0.1% chlorine solution; up to three decontamination steps were needed to make ifosfamide undetectable. Water or quaternary ammonium removed more than 99.5% of deliberate contamination. In several scenarios, it was necessary to repeat the decontamination to eliminate residual traces. More work is needed to identify the optimal decontamination approach for all of the antineoplastic drugs used.


Subject(s)
Antineoplastic Agents , Occupational Exposure , Decontamination , Equipment Contamination/prevention & control , Fluorouracil/analysis , Ifosfamide/analysis , Irinotecan , Methotrexate/analysis , Occupational Exposure/analysis
16.
Talanta ; 217: 121040, 2020 Sep 01.
Article in English | MEDLINE | ID: mdl-32498908

ABSTRACT

Antineoplastic agents are, for most of them, highly toxic drugs prepared at hospital following individualized prescription. To protect patients and healthcare workers, it is important to develop analytical tools able to identify and quantify such drugs on a wide concentration range. In this context, surface enhanced Raman spectroscopy (SERS) has been tested as a specific and sensitive technique. Despite the standardization of the nanoparticle synthesis, a polydispersity of nanoparticles in the suspension and a lack of reproducibility persist. This study focuses on the development of a new mathematical approach to deal with this nanoparticle polydispersity and its consequences on SERS signal variability through the feasibility of 5-fluorouracil (5FU) quantification using silver nanoparticles (AgNPs) and a handled Raman spectrophotometer. Variability has been maximized by synthetizing six different batches of AgNPs for an average size of 24.9 nm determined by transmission electron microscopy, with residual standard deviation of 17.0%. Regarding low performances of the standard multivariate data processing, an alternative approach based on the nearest neighbors were developed to quantify 5FU. By this approach, the predictive performance of the 5FU concentration was significantly improved. The mean absolute relative error (MARE) decreased from 16.8% with the traditional approach based on PLS regression to 6.30% with the nearest neighbors approach (p-value < 0.001). This study highlights the importance of developing mathematics adapted to SERS analysis which could be a step to overcome the spectral variability in SERS and thus participate in the development of this technique as an analytical tool in quality control to quantify molecules with good performances, particularly in the pharmaceutical field.


Subject(s)
Antineoplastic Agents/analysis , Fluorouracil/analysis , Metal Nanoparticles/chemistry , Silver/chemistry , Humans , Least-Squares Analysis , Nonlinear Dynamics , Particle Size , Spectrum Analysis, Raman , Surface Properties
17.
Anal Chim Acta ; 1122: 1-8, 2020 Jul 25.
Article in English | MEDLINE | ID: mdl-32503739

ABSTRACT

Highly sensitive and selective detection of DNA adenine methylation methyltransferase (Dam MTase) activity is essential for clinical diagnosis and treatment as Dam MTase can catalyze DNA methylation and has a profound effect on gene regulation. In this study, a fluorescence biosensor has been developed for label-free detection of Dam MTase activity via methylation-sensitive cleavage primers triggered hyperbranched rolling circle amplification (HRCA). A hairpin DNA probe (HP) with a Dam MTase specific recognition sequence on the stem acting as a substrate has been designed. This substrate probe can be methylated by the target in the system and subsequently cleaved by DpnI, which results in the release of the primer release probe (RP) and hence in turn triggers the subsequent HRCA reaction. As the HRCA products contain many double-strand DNA (dsDNA) with different lengths, and the SYBR Green I can be embedded in the dsDNA to produce a strong fluorescence signal. However, in the absence of the target, the presence of the probe HP in the form of a hairpin cannot induce the HRCA reaction, and only weak fluorescence intensity can be detected. Under the optimized conditions, the fluorescence of the system has a linear relationship with the logarithm of the concentration of Dam MTase in the range of 2.5-70 U/mL with a detection limit of 1.8 U/mL. The Dam MTase can be well distinguished from other MTase analogs. The developed sensor was applied to detect target in serum and E. coli cell lysate, and the standard recovery rates were in the range of 96%-105%. The results showed that this method has great potential for assessing Dam MTase activity in complex biological samples. In addition, the method has been applied to detect the related inhibitors with high efficiency.


Subject(s)
Biosensing Techniques , Enzyme Inhibitors/analysis , Fluorescence , Fluorouracil/analysis , Nucleic Acid Amplification Techniques , Site-Specific DNA-Methyltransferase (Adenine-Specific)/metabolism , DNA Methylation/drug effects , DNA Probes , Enzyme Inhibitors/pharmacology , Escherichia coli/enzymology , Fluorouracil/pharmacology , Humans , Site-Specific DNA-Methyltransferase (Adenine-Specific)/antagonists & inhibitors
18.
J Mol Model ; 26(7): 169, 2020 Jun 09.
Article in English | MEDLINE | ID: mdl-32519091

ABSTRACT

We studied the potential application of the pristine and Al-doped graphyne-like BN nanosheets (Al-BN-yne) in 5-fluorouracil (5-FU) drug detection using DFT calculations. The 5-FU drug preferentially adsorbed via its oxygen atom on the B atom of pristine BN-yne with adsorption energy of - 11.7 kcal/mol and no effect on its electronic properties. Replacing a B atom by an Al atom significantly increased the sensitivity and reactivity of BN-yne to the 5-FU drug. Upon the 5-FU interaction with the Al-BN-yne, an energy of 20.3 kcal/mol is released, and the Eg of Al-BN-yne significantly decreased from 4.83 to 3.80 eV, increasing the electrical conductance. Thus, the Al-BN-yne sheet can generate an electronic signal after the 5-FU drug adsorption, being a promising electronic sensor for 5-FU detection. We predicted that the recovery time for 5-FU drug desorption from the Al-BN-yne sheet surface is 0.07 s, demonstrating that it benefits from a short recovery time.


Subject(s)
Aluminum Compounds/chemistry , Antimetabolites, Antineoplastic/analysis , Boron Compounds/chemistry , Drug Monitoring , Fluorouracil/analysis , Graphite/chemistry , Metal Nanoparticles , Nanomedicine , Adsorption , Density Functional Theory , Models, Molecular , Surface Properties , Time Factors , Workflow
19.
J Sep Sci ; 43(15): 3074-3082, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32432394

ABSTRACT

Chemotherapeutics are pharmaceutical compounds the occurrence of which in the environment is of growing concern because of the increase in treatments against cancer diseases. They can reach the aquatic ecosystems after passing through wastewater treatment plants without complete removal. One of the most frequently used chemotherapeutics is 5-fluorouracil which exhibits a strong cytostatic effect. In this paper, an analytical methodology was developed, validated, and applied to determine 5-fluorouracil, its precursor, 5-fluorocytosine, and its major active metabolite, 5-fluorouridine, in hospital wastewater samples. Due to the expected low concentrations after dilution and interferences present in such a complex matrix, a very selective and sensitive detection method is required. Moreover, an extraction method must be implemented prior to the determination in order to purify the sample extract and preconcentrate the target analytes at micrograms per liter concentration levels. Solid-phase extraction followed by liquid chromatography with tandem mass spectrometry was the combination of choice and all included parameters were studied. Under optimized conditions for wastewater samples analysis, recoveries from 63 to 108% were obtained, while intraday and interday relative standard deviations never exceeded 20 and 25%, respectively. Limits of detection between 61 and 620 ng/L were achieved. Finally, the optimized method was applied to samples from hospital wastewater effluents.


Subject(s)
Flucytosine/analysis , Fluorouracil/analysis , Hospitals , Uridine/analogs & derivatives , Wastewater/chemistry , Water Pollutants, Chemical/analysis , Chromatography, High Pressure Liquid , Molecular Structure , Solid Phase Extraction , Tandem Mass Spectrometry , Uridine/analysis
20.
J Oncol Pharm Pract ; 26(8): 1864-1870, 2020 Dec.
Article in English | MEDLINE | ID: mdl-32138611

ABSTRACT

PURPOSE: The objective of this pilot study was to determine the frequency of urination and the concentration of four hazardous drugs (cyclophosphamide, ifosfamide, methotrexate, and fluorouracil) in workers' 24-h urine samples in relation to exposure to traces with hazardous drugs. METHODS: The study was conducted in three healthcare centers in the region of Montréal, Quebec, Canada. We recruited healthcare workers (nurses and pharmacy technicians) assigned to the hematology-oncology department. Each participant was asked to collect all urine voided during a 24-h period, to fill out an activity journal documenting tasks performed and to document the use of personal protective equipment. Samples were analyzed for cyclophosphamide, ifosfamide, methotrexate, and alpha-fluoro-beta-alanine (FBAL, the main urinary metabolite of 5-fluorouracil). Drugs were quantified by ultra-performance liquid chromatography-tandem mass spectrometry (positive electrospray MRM mode). RESULTS: Eighteen healthcare workers (10 nurses and 8 technicians) were recruited and provided consent to participate. Urine samples were obtained between 1 September and 30 September 2019. The number of urinations over the 24-h collection period ranged from 3 to 11 per participant. A total of 128 urine samples were analyzed for the 18 workers. All urine samples were negative for the four antineoplastics tested. CONCLUSION: No traces of cyclophosphamide, ifosfamide, methotrexate, or FBAL were found in the 24-h urine samples of 18 healthcare workers practicing in three healthcare facilities in Quebec. Although it was feasible to collect 24-h urine samples in this research project, it appears unrealistic to do so recurrently as part of a large-scale surveillance program.


Subject(s)
Antineoplastic Agents/analysis , Environmental Monitoring/methods , Occupational Exposure/analysis , Adult , Canada , Chromatography, Liquid , Cyclophosphamide/analysis , Fluorouracil/analysis , Health Personnel , Humans , Ifosfamide/analysis , Methotrexate/analysis , Middle Aged , Personal Protective Equipment , Pharmacy Technicians , Pilot Projects , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...