Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.926
Filter
1.
J Med Case Rep ; 18(1): 234, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38698425

ABSTRACT

BACKGROUND: Nexplanon implants are a common hormonal contraceptive modality. Though rare, these devices can embolize into the injured wall of the basilic vein, through the right heart, and finally wedge itself into a pulmonary artery. With adherence to the arterial wall over time, it becomes less amenable to endovascular retrieval. Patients may present with symptoms mimicking a pulmonary embolism, or without any symptoms at all. In asymptomatic cases, endovascular retrieval and/or surgery is required when patients wish to begin having children prior to biological inactivity. The current literature showed as little as nine case reports detailing lung tissue removal in the aim of reversing a patient's implanted contraceptive device. CASE PRESENTATION: A 22-year-old asymptomatic active-duty Caucasian female presented for elective outpatient Nexplanon removal. The suspicion of possible implant migration arose when it was discovered to be non-palpable in her left arm. After plain film x-rays failed to localize the implant, a chest x-ray and follow-up Computed Tomography (CT) scan revealed that the Nexplanon had migrated to a distal branch of the left pulmonary artery. Due to the patient's strong desires to begin having children, the decision was made for removal. Initial endovascular retrieval failed due to Nexplanon encapsulation within the arterial wall. Ultimately, the patient underwent a left video-assisted thoracoscopic surgery (VATS) for exploration and left lower lobe basilar S7-9 segmentectomy, which successfully removed the Nexplanon. CONCLUSIONS: Implanted contraceptive devices can rarely result in migration to the pulmonary vasculature. These radiopaque devices are detectable on imaging studies if patients and clinicians are unable to palpate them. An endovascular approach should be considered first to spare lung tissue and avoid chest-wall incisions, but can be complicated by encapsulation and adherence to adjacent tissue. A VATS procedure with single-lung ventilation via a double-lumen endotracheal tube allows surgeons to safely operate on an immobilized lung while anesthesiologists facilitate single-lung ventilation. This patient's case details the uncommon phenomenon of Nexplanon migration, and the exceedingly rare treatment resolution of lung resection to remove an embolized device.


Subject(s)
Desogestrel , Device Removal , Foreign-Body Migration , Humans , Female , Device Removal/methods , Desogestrel/administration & dosage , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Young Adult , Contraceptive Agents, Female/administration & dosage , Drug Implants , Pulmonary Artery/surgery , Pulmonary Artery/diagnostic imaging , Tomography, X-Ray Computed , Pulmonary Embolism/etiology , Treatment Outcome , Pneumonectomy
2.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
3.
J Investig Med High Impact Case Rep ; 12: 23247096241238527, 2024.
Article in English | MEDLINE | ID: mdl-38646799

ABSTRACT

Biliary endoprostheses are widely used in the treatment of biliary lithiasis, malignant and benign strictures, and occasionally in long-lasting biliary fistulas. They can be placed endoscopically during endoscopic retrograde cholangiopancreatography and radiologically (percutaneous) when the endoscopic route is not feasible. Complications associated with the endoscopic placement of biliary endoprostheses are well described in the literature, with migration being the most common. Intestinal obstruction is a rare complication associated with the migration of these devices. There are no reports in the literature of this complication occurring after percutaneous placement. We present a case of a patient who arrived at the emergency department with ileal obstruction secondary to the migration and concurrent embedding of a covered stent placed radiologically to treat a biliary leak after surgery. The patient underwent diagnostic laparoscopic and ileal resection, revealing a lithiasic concretion at the tip of the stent, causing the small bowel obstruction.


Subject(s)
Foreign-Body Migration , Intestinal Obstruction , Stents , Humans , Stents/adverse effects , Intestinal Obstruction/etiology , Intestinal Obstruction/surgery , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/complications , Male , Cholangiopancreatography, Endoscopic Retrograde , Female , Aged , Laparoscopy , Intestine, Small
4.
Article in English | MEDLINE | ID: mdl-38631862

ABSTRACT

Intrathoracic needles are rarely used in clinical practice. They can migrate within the body, injure large blood vessels and other organs, and cause severe complications. We report an interesting case of intrathoracic needle removal using video-assisted thoracoscopic surgery. The needle was inserted under the left clavicle, penetrated the mediastinum, and migrated into the right thoracic cavity. Although pneumothorax developed during the disease course, no severe complications were observed. This rare case illustrates the course of needle migration from the mediastinum into the thoracic cavity. Prompt imaging and surgical removal of foreign bodies are necessary in cases of intrathoracic foreign bodies.


Subject(s)
Foreign Bodies , Foreign-Body Migration , Thoracic Cavity , Humans , Mediastinum , Treatment Outcome , Thoracic Cavity/surgery , Foreign Bodies/surgery , Thoracic Surgery, Video-Assisted/methods , Foreign-Body Migration/surgery
5.
J Med Case Rep ; 18(1): 184, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38539178

ABSTRACT

BACKGROUND: Fractures of the clavicle are common injuries, which often require reduction and internal fixation. Although Kirschner pins have been commonly used to treat these fractures with good results, migration of these devices may result in severe internal lesions. CASE PRESENTATION: We report herein the case of 61-year-old man, who presented for intrapulmonary migration of a Kirschner pin, 25 years after closed reduction and fixation of a clavicle fracture. CONCLUSION: Migration of an osteosynthesis pin can be lethal. Patients with osteosynthesis pins, should have a regular follow, until the removal of the wires.


Subject(s)
Foreign-Body Migration , Fractures, Bone , Male , Humans , Middle Aged , Clavicle/diagnostic imaging , Clavicle/surgery , Clavicle/injuries , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/surgery , Fracture Fixation, Internal , Fractures, Bone/diagnostic imaging , Fractures, Bone/surgery , Bone Wires/adverse effects
8.
J Oral Implantol ; 50(2): 81-86, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38353278

ABSTRACT

Reports of implant fixtures dislocating into the maxillary sinus during sinus graft procedures are well-documented. However, cases of fixtures migrating into the sinus long after placement have yet to be reported. This case report details the surgical extraction of a displaced screw and cement-retained prosthesis, including a fixture and its abutment, from the maxillary sinus after a minimum of 5 years under functional load. The extracted implant was subsequently examined using scanning electron microscopy and energy-dispersive x-ray spectroscopy. We found that the migration commenced with peri-implantitis surrounding the implant, replacing the second molar. This was accompanied by a loss of cement from the crown on this implant and concurrent loosening of the abutment screw on the implant, replacing the first molar. We hypothesize that the inability of the bony tissue surrounding the second molar implant to withstand occlusal forces resulted in forming a bony sequestrum. This process ultimately precipitated the migration of the fixture, along with its abutment and adjacent necrotic bone, into the sinus cavity.


Subject(s)
Foreign-Body Migration , Maxillary Sinus , Humans , Maxillary Sinus/surgery , Foreign-Body Migration/surgery , Microscopy, Electron, Scanning , Peri-Implantitis/etiology , Peri-Implantitis/surgery , Dental Restoration Failure , Dental Implants , Male , Middle Aged , Device Removal , Dental Abutments , Female , Molar
9.
Vasc Endovascular Surg ; 58(5): 559-566, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38196287

ABSTRACT

INTRODUCTION AND IMPORTANCE: Long-term mechanical complications after inferior vena cava (IVC) filter placement include embedded or tilted filters, erosion of the vena cava, filter thrombosis. In the setting of caval thrombosis, patients may subsequently develop venous hypertension and post-thrombotic syndrome (PTS). Here we present three unique cases of IVC filter complications and surgical management. CASE PRESENTATION: A 30-year-old female presented with acute abdominal pain, revealing a duodenal perforation caused by an IVC filter eroding into her duodenum. A 42-year-old female with an IVC filter in place for 20 years due to a prior pulmonary embolism underwent laser-assisted retrieval of the filter due to concerns of caval adherence. A 48-year-old male with a history of DVT, venous stasis ulcer, and an IVC filter presented for filter retrieval. CLINICAL FINDINGS AND INVESTIGATIONS: The surgical techniques described in this report include complicated IVC filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis resulting in PTS. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. INTERVENTION AND OUTCOMES: The surgical techniques described in this report include complicated inferior vena cava filter retrieval, performed in cases of filter complications including migration, fracture, duodenal perforation and IVC thrombosis. One case, requiring open retrieval, is explained and the surgical technique is provided. There are images and videos of these procedures to enrich the learning experience. RELEVANCE AND IMPACT: Endovascular retrieval of long-term complicated IVC filters is challenging, but it can be a safely performed in many patients. However, open surgery may be necessary in selected patients.


Subject(s)
Device Removal , Foreign-Body Migration , Vena Cava Filters , Vena Cava, Inferior , Venous Thrombosis , Humans , Vena Cava Filters/adverse effects , Male , Middle Aged , Female , Adult , Treatment Outcome , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/surgery , Vena Cava, Inferior/diagnostic imaging , Vena Cava, Inferior/injuries , Vena Cava, Inferior/surgery , Venous Thrombosis/etiology , Venous Thrombosis/diagnostic imaging , Venous Thrombosis/therapy , Intestinal Perforation/etiology , Intestinal Perforation/surgery , Intestinal Perforation/diagnostic imaging , Prosthesis Implantation/instrumentation , Prosthesis Implantation/adverse effects , Time Factors , Prosthesis Design , Phlebography
10.
Vasc Endovascular Surg ; 58(5): 567-570, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38240584

ABSTRACT

Coil migration during endovascular embolization is a complication that can result in thromboembolic occlusion leading to potentially large infarcts if not removed. Microsnares are commonly used to remove migrated coils. Current techniques, however, struggle in cases where the microsnare is unable to loop over and secure a free end of the coil. We present a case in which a microsnare combined with a microwire successfully removed a migrated coil in a patient with a bleeding hepatic pseudoaneurysm post-embolization. This technique proved beneficial when traditional methods were insufficient, especially in small vessels or coil packs that cannot be snared. The synergy of the microsnare and microwire technique presents a promising solution for challenging migrated coil retrievals.


Subject(s)
Aneurysm, False , Device Removal , Embolization, Therapeutic , Foreign-Body Migration , Humans , Foreign-Body Migration/etiology , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/therapy , Foreign-Body Migration/surgery , Embolization, Therapeutic/instrumentation , Treatment Outcome , Aneurysm, False/diagnostic imaging , Aneurysm, False/therapy , Aneurysm, False/etiology , Hepatic Artery/diagnostic imaging , Male , Hemorrhage/etiology , Hemorrhage/therapy , Aged , Equipment Design , Female
12.
Childs Nerv Syst ; 40(2): 587-591, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37855877

ABSTRACT

Intracardiac migration is a rare complication of ventriculoperitoneal shunt insertion. Only 15 cases have been reported, 7 of which were paediatric cases, treated with techniques including interventional radiography, open thoracotomies and direct extraction through the initial shunt incision. The authors report the youngest case of intracardiac shunt migration complicated by significant coiling and knotting within the cardiac chambers and pulmonary vasculature. Migration likely began when the SVC was pierced during initial shunt placement and progressed due to negative intrathoracic pressure. Extrusion was achieved combining thoracoscopic endoscopy, interventional fluoroscopy screening and a posterolateral neck incision with uncoiling of the shunt via a Seldinger guide wire. This offered a minimally invasive solution with rapid post-operative recovery.


Subject(s)
Foreign-Body Migration , Ventriculoperitoneal Shunt , Humans , Child , Ventriculoperitoneal Shunt/adverse effects , Ventriculoperitoneal Shunt/methods , Catheters/adverse effects , Catheterization , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/surgery
13.
Childs Nerv Syst ; 40(1): 19-25, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37857859

ABSTRACT

OBJECTIVE: The incidence of scrotal migration of a ventriculoperitoneal shunt (VPS) catheter is rare and may lead to life-threatening visceral complications. Management requires prompt removal of the migrated portion of the shunt and closure of the scrotal sac. We report an interesting case of a young child who presented with asymptomatic unilateral swelling of his scrotum secondary to a migrated VPS catheter. A repeat X-ray prior to his surgery to remove the migrated catheter showed that the entire length of the distal VPS catheter was back in the peritoneal cavity. In view of this unusual phenomenon, the case is discussed in corroboration with published literature. METHODS AND RESULTS: A systematic search of publications in the English language is performed in PubMed and Google Scholar. Our findings show that there are 49 reported cases (including our patient) of scrotal migration of shunt catheters in patients less than 18 years old. There is only 1 other case of spontaneous resolution of shunt catheter from the scrotum. Favoured management of choice is repositioning the distal shunt catheter back into the peritoneal cavity and herniotomy in the same setting, if possible. Overall, the literature suggests this is a shunt-related complication that has a good prognosis if intervention is timely. CONCLUSION: Scrotal migration of a VPS catheter is a rare but potentially life-threatening complication in children. Our case report highlights the role of updated preoperative imaging and the need for consistent long-term shunt surveillance in children.


Subject(s)
Foreign-Body Migration , Hydrocephalus , Male , Child , Humans , Adolescent , Scrotum/surgery , Ventriculoperitoneal Shunt/adverse effects , Peritoneum , Remission, Spontaneous , Hydrocephalus/surgery , Catheters/adverse effects , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Foreign-Body Migration/surgery
16.
Rev Gastroenterol Peru ; 43(3): 273-276, 2023.
Article in Spanish | MEDLINE | ID: mdl-37890854

ABSTRACT

This is a case report of a 47-year-old woman, carrier of an adjustable gastric band since 2018, that developed abdominal pain due to partial migration into the stomach. which was successfully removed endoscopically using Sohendra's lithotriptor.


Subject(s)
Foreign-Body Migration , Gastroplasty , Female , Humans , Middle Aged , Abdominal Pain , Endoscopy , Foreign-Body Migration/diagnosis , Foreign-Body Migration/surgery , Foreign-Body Migration/etiology , Gastroplasty/adverse effects , Stomach
SELECTION OF CITATIONS
SEARCH DETAIL
...