Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21.699
Filter
1.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38728525

ABSTRACT

CASE: Two patients with osteopetrosis underwent conversion total hip arthroplasty (THA) after failure of internal fixation due to hip fractures. We experienced challenges, including difficulty of hardware removal, remaining of previous broken screws in the canal, difficulty in finding the femoral canal, and an intraoperative acetabulum fracture. Despite complications, both patients achieved satisfactory functional outcome after surgery at the latest follow-up. CONCLUSION: Our cases showed that previous hip fracture and failed internal fixation make conversion THA more complex and unpredictable in patients with osteopetrosis. This in turn underscores the critical need for advanced preoperative planning, intraoperative flexibility, and meticulous postoperative care.


Subject(s)
Arthroplasty, Replacement, Hip , Osteopetrosis , Humans , Arthroplasty, Replacement, Hip/methods , Osteopetrosis/surgery , Osteopetrosis/complications , Female , Hip Fractures/surgery , Male , Middle Aged , Fracture Fixation, Internal/methods , Aged
2.
Am J Case Rep ; 25: e943136, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38706183

ABSTRACT

BACKGROUND Hoffa fractures are an uncommon form of coronal fracture that impact the femoral condyle. As a result, they are not very prevalent. It is necessary to perform anatomical reduction and rigorous fixation on these fractures; however, there is no consensus among medical professionals on the surgical procedure and implant that would be the most successful in treating these fractures. CASE REPORT A 50-year-old woman who had poliomyelitis in her right lower limb presented with a displaced medial Hoffa fracture of her left knee. She had fallen and was suffering from poliomyelitis. The trauma that caused this fracture had a modest energy level. Open reduction and internal fixation with 2 retrograde cannulated screws were included in her surgical procedure. An approach known as the medial parapatellar route was used for this treatment. As part of her postoperative rehabilitation, she participated in physiotherapy, exercises that did not require weight bearing, exercises that used passive and active assistance, activities that involved partial and full weight bearing, and exercises that involved complete weight bearing. At the 2-year follow-up, the patient's left knee continued to be painless and stable, and it had unrestricted range of motion across the whole extremity. It was determined via radiographs that the fracture had healed without any problems or arthritic changes developing. She was able to walk without help and carry out her daily tasks since she was able to walk with the use of a cane. CONCLUSIONS Retrograde cannulated screws can be a reliable and successful choice for treatment of medial Hoffa fractures, with positive results according to both clinical and radiographic characteristics. Further research is needed to analyze the outcomes over a longer period of time and make comparisons between this technique and others.


Subject(s)
Femoral Fractures , Fracture Fixation, Internal , Humans , Female , Middle Aged , Fracture Fixation, Internal/methods , Femoral Fractures/surgery , Femoral Fractures/diagnostic imaging , Bone Screws , Open Fracture Reduction , Poliomyelitis/complications , Hoffa Fracture
3.
BMC Vet Res ; 20(1): 188, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730373

ABSTRACT

Femoral fractures are often considered lethal for adult horses because femur osteosynthesis is still a surgical challenge. For equine femur osteosynthesis, primary stability is essential, but the detailed physiological forces occurring in the hindlimb are largely unknown. The objective of this study was to create a numerical testing environment to evaluate equine femur osteosynthesis based on physiological conditions. The study was designed as a finite element analysis (FEA) of the femur using a musculoskeletal model of the loading situation in stance. Relevant forces were determined in the musculoskeletal model via optimization. The treatment of four different fracture types with an intramedullary nail was investigated in FEA with loading conditions derived from the model. The analyzed diaphyseal fracture types were a transverse (TR) fracture, two oblique fractures in different orientations (OB-ML: medial-lateral and OB-AP: anterior-posterior) and a "gap" fracture (GAP) without contact between the fragments. For the native femur, the most relevant areas of increased stress were located distally to the femoral head and proximally to the caudal side of the condyles. For all fracture types, the highest stresses in the implant material were present in the fracture-adjacent screws. Maximum compressive (-348 MPa) and tensile stress (197 MPa) were found for the GAP fracture, but material strength was not exceeded. The mathematical model was able to predict a load distribution in the femur of the standing horse and was used to assess the performance of internal fixation devices via FEA. The analyzed intramedullary nail and screws showed sufficient stability for all fracture types.


Subject(s)
Femoral Fractures , Fracture Fixation, Internal , Hindlimb , Animals , Horses/physiology , Biomechanical Phenomena , Femoral Fractures/veterinary , Femoral Fractures/surgery , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Hindlimb/surgery , Finite Element Analysis , Femur/surgery , Models, Biological , Weight-Bearing , Fracture Fixation, Intramedullary/veterinary , Fracture Fixation, Intramedullary/instrumentation
4.
BMC Musculoskelet Disord ; 25(1): 368, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38730497

ABSTRACT

BACKGROUND: This systemic review and meta-analysis aimed to evaluate the clinical outcomes of proximal humeral fracture in elderly patient fixation using locked plate with or without cement augmentation. METHODS: The databases of PubMed, Embase, and Cochrane Library were searched in August 2023 for literature comparing the clinical outcomes of patients with PHFs treated with locked plate alone and locked plate augmented with cement. Data describing study design; level of evidence; inclusion criteria; demographic information; final follow-up; revision rate; implant failure rate; avascular necrosis rate; total complication rate; constant score; and disability of arm, shoulder, and hand (DASH) score were collected. RESULTS: Eight studies (one randomized-controlled trial and seven observational studies), involving 664 patients, were identified. Compared with locked plates alone, using cement-augmented locked plates reduced the implant failure rate (odds ratio (OR) = 0.19; 95% confidence interval (CI) 0.10-0.39; P < 0.0001) and total complication rate (OR = 0.45; 95% CI 0.29-0.69; P = 0.0002) and improved DASH scores (mean difference (MD) = 2.99; 95% CI 1.00-4.98; P = 0.003). However, there was no significant difference in clinical outcomes, including revision rate, avascular necrosis rate, and constant score. CONCLUSION: In this review and meta-analysis, fixation of the PHFs in elderly patients using locked plates with or without cement augmentation has no significant difference in revision rate, but the implant failure and total complication rates may be lesser on using the cement-augmented locked plate for fixation than on using a locked plate alone. Good results are expected for most patients treated with this technique. TRIAL REGISTRATION: The Preferred Reporting Items for Systematic Reviews and Meta-Analyses (PRISMA)21 guidelines were followed to conduct this systematic review and meta-analysis and was registered as a protocol in PROSPERO (CRD42022318798).


Subject(s)
Bone Cements , Bone Plates , Fracture Fixation, Internal , Shoulder Fractures , Humans , Shoulder Fractures/surgery , Shoulder Fractures/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Bone Cements/therapeutic use , Bone Cements/adverse effects , Aged , Treatment Outcome , Aged, 80 and over , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Reoperation
5.
Dan Med J ; 71(5)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38704836

ABSTRACT

INTRODUCTION: Following surgical management of patella fractures, patients commonly report pain; difficulties with weight-bearing tasks such as walking, running and climbing stairs; and restrictions in quality of life. Recently, a locking plate system for surgical management of patella fractures has been introduced. To date, no studies have compared standard treatment with tension band wiring with locking plate fixation in a randomised study design. We aim to compare the one-year patient-reported Knee Injury and Osteoarthritis Outcome subscale scores (KOOS5-subscales) after standard care tension band fixation with locking plate fixation for patients with patella fractures. METHODS: This is a multicentre randomised and prospective clinical trial. A total of 122 patients will be included in the study, and the primary outcome will be the KOOS subscales at 12 months after surgery. CONCLUSIONS: Findings from the present study are expected to advance our understanding of outcome following surgical treatment of patella fractures. FUNDING: This study is funded, in part, by the Novo Nordisk Foundation, Denmark. CLINICALTRIALS: gov ID: NCT04891549.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Bone , Patella , Humans , Patella/injuries , Patella/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Fractures, Bone/surgery , Prospective Studies , Female , Male , Treatment Outcome , Bone Wires , Adult , Randomized Controlled Trials as Topic , Middle Aged , Denmark , Quality of Life , Patella Fracture
6.
BMC Musculoskelet Disord ; 25(1): 362, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38714945

ABSTRACT

BACKGROUND: Open tibial fractures often include severe bone loss and soft tissue defects and requires complex reconstructive operations. However, the optimal treatment is unclear. METHODS: This retrospective study enrolled patients with Gustilo type III open tibial fractures from January 2018 to January 2021 to assess the clinical utility of Masquelet technique together with microsurgical technique as a combined strategy for the treatment of open tibial fractures. The demographics and clinical outcomes including bone union time, infection, nonunion and other complications were recorded for analysis. The bone recovery quality was evaluated by the AOFAS Ankle-Hindfoot Scale score and the Paley criteria. RESULTS: We enrolled 10 patients, the mean age of the patients and length of bone defects were 31.7 years (range, 23-45 years) and 7.5 cm (range, 4.5-10 cm) respectively. Bone union was achieved for all patients, with an average healing time of 12.2 months (range, 11-16 months). Seven patients exhibited a bone healing time of less than 12 months, whereas 3 patients exhibited a bone healing time exceeding 12 months. No significant correlation was found between the length of bone loss and healing time. In addition, no deep infection or nonunion was observed, although 2 patients experienced wound fat liquefaction with exudates and 1 patient presented with a bloated skin flap. The average AOFAS Ankle-Hindfoot Scale score was 80.5 (range, 74-85), and all patients were evaluated as good or exellent based on the Paley criteria. CONCLUSIONS: Our study indicated that the use of the Masquelet technique and the microsurgical technique as a combined strategy is safe and effective for the treatment of Gustilo type III open tibial fractures.


Subject(s)
Fracture Healing , Fractures, Open , Microsurgery , Tibial Fractures , Humans , Tibial Fractures/surgery , Tibial Fractures/diagnostic imaging , Male , Middle Aged , Retrospective Studies , Fractures, Open/surgery , Adult , Female , Microsurgery/methods , Young Adult , Treatment Outcome , Fracture Fixation, Internal/methods , Plastic Surgery Procedures/methods , Bone Transplantation/methods
7.
Trials ; 25(1): 305, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711052

ABSTRACT

BACKGROUND: To analyze the perioperative bleeding and hidden blood loss (HBL) of sacroiliac screw minimally invasive treatment of pelvic posterior ring injury and explore the influential factors of HBL after operation for providing reference for clinical treatment. METHOD: A retrospective analysis was conducted on data from 369 patients with posterior pelvic ring injuries treated with sacroiliac screws internal fixation at our hospital from January 2015 to January 2022. The research was registered in the Chinese Clinical Trial Registry in July 2022 (ChiCTR2200061866). The total blood loss (TBL) and HBL of patients were counted, and the factors such as gender, age, and surgical duration were statistically analyzed. The influential factors of HBL were analyzed by multiple linear regression. RESULTS: The TBL was 417.96 ± 98.05 ml, of which the visible blood loss (VBL) was 37.00 ± 9.0 ml and the HBL was 380.96 ± 68.8 ml. The HBL accounted for 91.14 ± 7.36% of the TBL. Gender, surgical duration, fixed position, and fixed depth had significant effects on the HBL (P < 0.05). CONCLUSIONS: The HBL was the main cause of anemia after minimally invasive treatment of posterior pelvic ring injury with a sacroiliac screw. Gender, surgical duration, fixed position, and fixed depth were closely related to the occurrence of HBL. In clinical treatment, we should consider these influential factors and take effective measures to reduce the impact of HBL on patients.


Subject(s)
Blood Loss, Surgical , Bone Screws , Fracture Fixation, Internal , Pelvic Bones , Humans , Male , Female , Retrospective Studies , Pelvic Bones/injuries , Pelvic Bones/surgery , Adult , Middle Aged , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Treatment Outcome , Risk Factors , Young Adult , Fractures, Bone/surgery , Fractures, Bone/diagnostic imaging , Time Factors , China , Aged , Minimally Invasive Surgical Procedures/methods , Anemia/etiology
8.
J Plast Surg Hand Surg ; 59: 46-52, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38747532

ABSTRACT

Standard volar plates often do not fit the surface of the malunited distal radius after osteotomy, necessitating an offset angle for accurate volar tilt correction. The correction can be achieved if the plate is held at the correct angle when the distal screws are locked. With the advantage of 3D surgical planning and patient-specific instruments, we developed a shim instrument to assist the surgeon in securing the plate at the intended angle when locking the distal screws, and evaluated radiological results. Five female patients aged 63-74 with dorsally angulated extra-articular malunions underwent surgery using 3D-printed guides and the shim instrument. The plate position, drilling guide alignment, screw placements, and distal radius correction on postoperative CTs were compared with the surgical plans. Errors were measured using an anatomical coordinate system, and standard 2D radiographic measures were extracted. Preoperative dorsal tilt ranged from 16° to 35°, and postoperative volar tilt from 1° to 11°. 3D analysis revealed mean absolute correction errors of 6.1° in volar tilt, 1.6° in radial inclination, and 0.6 mm in ulnar variance. The volar tilt error due to the shim instrument, indicated by the mean angle error of the distal screws to the plate, was 2.1° but varied across the five patients. Settling of the distal radius, due to tension during and after reduction, further contributed to a mean loss of 3.5° in volar tilt. The shim instrument helped with securing plates at the intended angle; however, further correction improvements should consider the tension between the fragments of osteoporotic bone.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Fractures, Malunited , Osteotomy , Radius Fractures , Humans , Female , Osteotomy/methods , Osteotomy/instrumentation , Middle Aged , Radius Fractures/surgery , Radius Fractures/diagnostic imaging , Aged , Fractures, Malunited/surgery , Fractures, Malunited/diagnostic imaging , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Printing, Three-Dimensional , Surgery, Computer-Assisted , Imaging, Three-Dimensional , Bone Screws , Tomography, X-Ray Computed
9.
J Int Med Res ; 52(5): 3000605241238983, 2024 May.
Article in English | MEDLINE | ID: mdl-38729774

ABSTRACT

OBJECTIVE: This study was performed to evaluate the mid-term clinical efficacy of the Femoral Neck System (FNS) (DePuy Synthes, Zuchwil, Switzerland) in treating young patients with unstable Pauwels type III femoral neck fractures. METHODS: We performed a retrospective observational analysis of 21 young adults treated with the FNS. Clinical outcomes were assessed based on fracture reduction quality, Harris hip scores, and postoperative complication rates. RESULTS: The study comprised 21 patients with a mean age of 35 years (range, 20-50 years) who were followed for a mean duration of 22.8 months (range, 16-30 months). Closed reduction was unfeasible in three (14.3%) patients, each of whom required open reduction. Notable postoperative complications were avascular necrosis in two (9.5%) patients, nonunion in one (4.7%), and implant failure in one (4.7%). Each of these complications led to the requirement for total hip arthroplasty. CONCLUSION: The favorable mid-term clinical outcomes of this study indicate that the FNS is a potentially effective treatment modality for young individuals with unstable Pauwels type III femoral neck fractures.


Subject(s)
Femoral Neck Fractures , Fracture Fixation, Internal , Humans , Femoral Neck Fractures/surgery , Male , Female , Adult , Retrospective Studies , Young Adult , Middle Aged , Treatment Outcome , Fracture Fixation, Internal/methods , Postoperative Complications/etiology , Femur Neck/surgery , Femur Head Necrosis/surgery , Femur Head Necrosis/etiology
10.
J Orthop Surg Res ; 19(1): 290, 2024 May 12.
Article in English | MEDLINE | ID: mdl-38735949

ABSTRACT

BACKGROUND: As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws). METHODS: A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation. RESULTS: Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively. CONCLUSIONS: The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.


Subject(s)
Bone Screws , Femoral Neck Fractures , Finite Element Analysis , Fracture Fixation, Internal , Humans , Biomechanical Phenomena , Femoral Neck Fractures/surgery , Fracture Fixation, Internal/methods , Femur Neck/surgery , Femur Neck/diagnostic imaging , Femur/surgery , Stress, Mechanical , Device Removal/methods
11.
Acta Orthop ; 95: 206-211, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38712764

ABSTRACT

BACKGROUND AND PURPOSE: We aimed to assess joint failure rate, i.e., subsequent conversion to TKA after surgical treatment of a tibial plateau fracture (TPF). Secondary aims were to explore the association between joint failure and fracture type, and to determine the risk of failure associated with inadequate joint surface reduction. METHODS: We included all patients ≥ 18 years of age with a surgically treated TPF, treated at Uppsala University Hospital between 2002 and 2015. All fractures were classified according to the Arbeitsgemeinschaft für Osteosynthesefragen/Orthopaedic Traumatology Association (AO/OTA) classification. Postoperative radiographs were evaluated to determine the quality of joint surface inadequate reduction, defined as an articular step-off ≥ 2 mm. The study cohort was linked with the Swedish Arthroplasty Register (SAR) for information on subsequent total knee arthroplasty (TKA). RESULTS: 439 patients (57% women) with a mean age of 55 years (SD 17) were included. According to the AO/OTA classification, the fracture distribution was B1: 4.8%, B2: 10%, B3: 47%, C1: 12%, C2: 6.4%, and C3: 19%. 23 patients (5.2%) were converted to a TKA within 2 years of initial surgery, and 34 patients (7.7%) had been converted by the end of follow-up (16 years). AO/OTA type B3 and C3 had a 6.8 (95% confidence interval [CI] 1.6-29) times greater risk of joint failure compared with B1-2 and C1-C2 at 2 years' follow-up. Inadequate joint surface reduction led to an 8.4 (CI 3.6-20) times greater risk of conversion to TKA at 2 years' follow-up. CONCLUSION: Overall, 5.2% were converted to a TKA within 2 years. Fracture types AO/OTA B3 and C3 with a comminuted articular surface and inadequate joint surface reduction were strongly associated with joint failure.


Subject(s)
Arthroplasty, Replacement, Knee , Tibial Fractures , Humans , Female , Tibial Fractures/surgery , Arthroplasty, Replacement, Knee/adverse effects , Arthroplasty, Replacement, Knee/methods , Middle Aged , Male , Aged , Adult , Reoperation/statistics & numerical data , Cohort Studies , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Risk Factors , Sweden , Tibial Plateau Fractures
12.
J Coll Physicians Surg Pak ; 34(5): 568-572, 2024 May.
Article in English | MEDLINE | ID: mdl-38720218

ABSTRACT

OBJECTIVE: To explore the impact of the Geko neuromuscular stimulator on preoperative preparation in patients with ankle fractures. STUDY DESIGN: Quasi-experiment study. Place and Duration of the Study: Department of Foot and Ankle Surgery and Department of Orthopaedics, Beijing Tongren Hospital, Capital Medical University, Beijing, China, between December 2020 and 2021. METHODOLOGY: This quasi-experiment study included patients with ankle fractures treated with Geko neuromuscular stimulator before surgical fixation. The primary outcome was limb swelling at 24, 48, and 72 hours (h) after admission, and the secondary outcomes were pain according to visual analogue scale (VAS) at 12, 24, and 48 hours after admission, preoperative waiting time, and comfort 4 and 72 h after admission. RESULTS: A total of 60 patients were included in the study; 30 in the conventional treatment group (mean age 41.16 ± 2.01 years) and 30 in the Geko group (mean age 40.22 ± 2.68 years). The limb swelling in patients was significantly different between the Geko and conventional treatment groups (p = 0.004). Besides, the swelling values at 48 (p < 0.001) and 72 (p < 0.001) hours were significantly lower than those at 24 hours. The pain in patients was significantly different between the Geko and conventional treatment groups (p = 0.007). Besides, the swelling values at 24 (p < 0.001) and 48 (p < 0.001) hours are significantly lower than those at 24 hours. Comfort was significantly higher at 4 h (69.54 ± 2.18 vs. 67.22 ± 3.14, p = 0.002) and 72 h [(88.50 (84.00 - 94.00) vs. 82.14 ± 3.08, p < 0.001)] after admission. The preoperative waiting time (3.52 ± 1.8 vs. 5.15 ± 2.1 hours, p = 0.002) was significantly shorter in the Geko group. CONCLUSION: The Geko neuromuscular stimulator is a useful option for preoperative preparation in patients with ankle fractures to reduce local swelling and pain and improve patients' comfort. KEY WORDS: Ankle fractures, Lower extremity, Neuromuscular stimulator, Peroneal nerve, Pain.


Subject(s)
Ankle Fractures , Preoperative Care , Humans , Male , Female , Ankle Fractures/surgery , Adult , Preoperative Care/methods , Pain Measurement , Fracture Fixation, Internal/methods , Middle Aged , Electric Stimulation Therapy/methods , Treatment Outcome , China
13.
Jt Dis Relat Surg ; 35(2): 285-292, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727106

ABSTRACT

OBJECTIVES: The study aimed to investigate the factors associated with shoulder stiffness following open reduction and internal fixation (ORIF) of proximal humeral fractures. PATIENTS AND METHODS: The retrospective study included a total of 151 patients who underwent ORIF of proximal humeral fractures between January 2016 and May 2021. Based on their shoulder joint motion at the latest follow-up, the patients were divided into two groups. The stiffness group (n=32; 8 males, 24 females; mean age: 62.4±9.3 years; range, 31 to 79 years), exhibited restricted shoulder forward flexion (<120°), limited arm lateral external rotation (<30°), and reduced back internal rotation below the L3 level. The remaining patients were included in the non-stiffness group (n=119; 52 males, 67 females; mean age: 56.4±13.4 years; range, 18 to 90 years). Various factors were examined to evaluate the association with shoulder stiffness following ORIF of proximal humeral fractures by multivariate unconditional logistic regression models. RESULTS: The mean follow-up duration was 31.8±12.6 (range, 12 to 68) months. Based on the results of the multivariate regression analysis, it was found that high-energy injuries [compared to low-energy injuries; adjusted odds ratio (aOR)=7.706, 95% confidence interval (CI): 3.564-15.579, p<0.001], a time from injury to surgery longer than one week (compared to a time from injury to surgery equal to or less than one week; aOR=5.275, 95% CI: 1.7321-9.472, p=0.031), and a body mass index (BMI) >24.0 kg/m2 (compared to a BMI between 18.5 and 24.0 kg/m2 ; aOR=4.427, 95% CI: 1.671-11.722, p=0.023) were identified as risk factors for shoulder stiffness following ORIF of proximal humeral fractures. CONCLUSION: High-energy injury, time from injury to surgery longer than one week, and BMI >24.0 kg/m2 were identified as independent risk factors for shoulder stiffness after proximal humeral fracture surgery, which should be treated with caution in clinical treatment.


Subject(s)
Fracture Fixation, Internal , Open Fracture Reduction , Range of Motion, Articular , Shoulder Fractures , Humans , Male , Middle Aged , Shoulder Fractures/surgery , Female , Aged , Retrospective Studies , Adult , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Open Fracture Reduction/methods , Open Fracture Reduction/adverse effects , Shoulder Joint/surgery , Shoulder Joint/physiopathology , Aged, 80 and over , Risk Factors , Postoperative Complications/etiology , Postoperative Complications/epidemiology , Young Adult
14.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
15.
BMC Musculoskelet Disord ; 25(1): 343, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38693479

ABSTRACT

PURPOSE: To explore whether it is necessary to put drain tubes after posterior pedicle screw fixation of thoracolumbar fractures. METHODS: From April 2020 to January 2023, a total of 291 patients with recent thoracolumbar fractures (AO type-A or type-B) who received the pedicle screw fixation operation were enrolled retrospectively. In 77 patients, drain tubes were used in the pedicle screw fixation surgery, while no drain tubes were placed in the other group. After gleaning demographic information and results of lab examination and imageology examination, all data were put into a database. Independent-sample t-tests, Pearson Chi-Square tests, Linear regression analysis, and correlation analysis were then performed. RESULTS: Compared to the control group, the drainage group had significantly lower postoperative CRP levels (P = 0.047), less use of antipyretics (P = 0.035), higher ADL scores (P = 0.001), and lower NRS scores (P < 0.001) on the 6th day after surgery. Other investigation items, such as demographic information, operation time, intraoperative blood loss, body temperature, and other preoperative and postoperative lab results, showed no significant differences. CONCLUSIONS: The use of a drain tube in the pedicle screw fixation of thoracolumbar fractures is correlated with the improvement of patients' living and activity ability and the reduction of inflammation, postoperative fever and pain.


Subject(s)
Drainage , Fracture Fixation, Internal , Lumbar Vertebrae , Pedicle Screws , Spinal Fractures , Thoracic Vertebrae , Humans , Male , Thoracic Vertebrae/surgery , Thoracic Vertebrae/injuries , Spinal Fractures/surgery , Spinal Fractures/diagnostic imaging , Lumbar Vertebrae/surgery , Lumbar Vertebrae/injuries , Female , Retrospective Studies , Adult , Middle Aged , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/adverse effects , Drainage/instrumentation , Drainage/methods , Treatment Outcome , Aged
16.
Eur Rev Med Pharmacol Sci ; 28(8): 3208-3215, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38708479

ABSTRACT

OBJECTIVE: We sought to explore the effectiveness of cannulated screw fixation for femoral neck fractures in middle-aged and elderly patients assisted by a three-dimensional printing navigation template. PATIENTS AND METHODS: A total of 98 middle-aged and elderly patients who underwent cannulated screw fixation for femoral neck fractures were retrospectively analyzed. They were allocated into two groups, each comprising 49 patients. Surgical indexes, hip function, and pain levels were compared between the two groups. RESULTS: The study group, assisted by the three-dimensional printing navigation template, exhibited significantly reduced nail insertion, fewer instances of C-arm fluoroscopy, shorter operation time, quicker time to bone union, earlier initiation of walking exercise, shorter time to weight-bearing walking, and reduced hospital stay than those in the control group (all p<0.001). However, the study group also experienced higher blood loss compared to the control group (p<0.001). Postoperatively, at 3 months and 12 months, the study group demonstrated significantly higher scores compared to the control group (both p<0.001) and reported significantly lower pain scores than that in the other group at 1 week and 12 months post-surgery (both p<0.001). Furthermore, the study group experienced significantly fewer postoperative complications than the control group (p=0.029). CONCLUSIONS: Cannulated screw fixation for femoral neck fractures assisted by a 3D printing navigation template is more effective and safer than traditional fixation methods. This approach represents a promising alternative for surgical management.


Subject(s)
Bone Screws , Femoral Neck Fractures , Fracture Fixation, Internal , Printing, Three-Dimensional , Humans , Femoral Neck Fractures/surgery , Middle Aged , Aged , Female , Male , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies
17.
J Feline Med Surg ; 26(5): 1098612X241243134, 2024 May.
Article in English | MEDLINE | ID: mdl-38717791

ABSTRACT

CASE SERIES SUMMARY: A total of 13 cases of cats with a caudal mandibular fracture treated with a novel surgical technique using the Ramus Anatomical Plate system were reviewed. Preoperative, immediate postoperative and a minimum of 8 weeks postoperative CT images were required as inclusion criteria. The outcome and complications were determined from clinical data and radiographic follow-up examinations. All cases achieved adequate anatomical reduction, resulting in a functional and atraumatic occlusion postoperatively. No intraoperative complications were reported. Time to voluntary food intake was in the range of 1-25 days. No evidence of disruptions to the implants or screw loosening was observed in the 8-week postoperative CT imaging, with radiographic evidence of complete osseous union in all fractures. The most common postoperative complication was swelling at the surgical site. Two cats had postoperative exophthalmos due to retrobulbar haemorrhage, and one cat exhibited partial wound dehiscence 5 days postoperatively, which resolved with medical management. Longer-term complications included intraoral plate exposure in one cat, which required plate removal 10 months postoperatively. RELEVANCE AND NOVEL INFORMATION: In this case series, rigid internal fixation of caudal mandibular fractures using the Ramus Anatomical Plate osteosynthesis system was associated with a minimal complication rate, and satisfactory radiographic and clinical outcomes. The reported outcomes of this novel technique are favourable when compared with previous techniques described for the management of these fracture types.


Subject(s)
Bone Plates , Fracture Fixation, Internal , Mandibular Fractures , Cats/injuries , Animals , Bone Plates/veterinary , Fracture Fixation, Internal/veterinary , Fracture Fixation, Internal/methods , Mandibular Fractures/veterinary , Mandibular Fractures/surgery , Male , Female , Treatment Outcome , Postoperative Complications/veterinary , Tomography, X-Ray Computed/veterinary , Cat Diseases/surgery
18.
PLoS One ; 19(5): e0302839, 2024.
Article in English | MEDLINE | ID: mdl-38696506

ABSTRACT

PURPOSES: Fractures of the inferior patellar pole, unlike other patellar fractures, present challenges for traditional surgical fixation methods. This article introduces the clinical technique and outcomes of using Kirschner wire tension band combined with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures. METHODS: This retrospective case series study included 14 patients with comminuted inferior patellar pole fractures treated at our institution from September 1, 2020, to April 30, 2022. All patients underwent surgery using the Kirschner wire tension band with anchor screw cross-stitch technique. Follow-up assessments involved postoperative X-rays to evaluate fracture healing, as well as clinical parameters such as healing time, Visual Analog Scale (VAS) scores, range of motion (ROM), and Bostman scores. RESULTS: All patients were followed for an average of over 12 months, with no cases of internal fixation failure. Knee joint stability and function were excellent. X-rays revealed an average healing time of approximately 10.79 ± 1.53 weeks, hospitalization lasted 5.64 ± 1.15 days, surgery took approximately 37.86 ± 5.32 minutes, and intraoperative blood loss was 33.29 ± 8.15 ml. One patient experienced irritation from the internal fixation material. At the final follow-up, the Bostman score averaged 28.29 ± 0.83, knee joint flexion reached 131.07° ± 4.88°, all patients achieved full knee extension, and the VAS score was 0.36 ± 0.63. CONCLUSION: Kirschner wire tension band with anchor screw cross-stitch fixation for comminuted inferior patellar pole fractures delivered satisfactory clinical outcomes. This surgical method, characterized by its simplicity and reliability, is a valuable addition to clinical practice.


Subject(s)
Bone Wires , Fracture Fixation, Internal , Fractures, Comminuted , Patella , Humans , Male , Female , Adult , Patella/surgery , Patella/injuries , Fractures, Comminuted/surgery , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Retrospective Studies , Middle Aged , Range of Motion, Articular , Treatment Outcome , Fractures, Bone/surgery , Fracture Healing , Knee Joint/surgery , Knee Joint/physiopathology , Young Adult , Bone Screws , Suture Anchors
19.
JBJS Case Connect ; 14(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38709913

ABSTRACT

CASES: Two competitive athletes with isolated comminuted trapezium fractures, sustained during American football and rugby, presented with pain and swelling of the first metacarpal base. Computed tomography confirmed isolated comminuted trapezium fractures. Arthroscopic reduction of displacement with screw fixation below the articular surface was performed through a small incision. Both patients returned to their preinjury sports levels within 2 months postoperatively. CONCLUSION: Arthroscopic treatment of isolated comminuted trapezium fractures achieved accurate reduction of articular surface displacement and preserved trapeziometacarpal joint stability with minimal soft-tissue invasion. This facilitated an early return to contact sports for the affected athletes.


Subject(s)
Arthroscopy , Fractures, Comminuted , Trapezium Bone , Humans , Fractures, Comminuted/surgery , Fractures, Comminuted/diagnostic imaging , Trapezium Bone/surgery , Trapezium Bone/diagnostic imaging , Trapezium Bone/injuries , Arthroscopy/methods , Male , Adult , Fracture Fixation, Internal/methods , Young Adult , Athletic Injuries/surgery , Athletic Injuries/diagnostic imaging
20.
BMC Musculoskelet Disord ; 25(1): 350, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702748

ABSTRACT

BACKGROUND: Metacarpal shaft fracture is a common type of hand fracture. Numerous studies have explored fixing transverse fractures in the midshaft of the metacarpal bone. However, this section of the metacarpal bone is often susceptible to high-energy injury, resulting in comminuted fracture or bone loss. In such cases, wedge-shaped bone defects can develop in the metacarpal shaft, increasing the difficulty of performing fracture fixation. Notably, the research on this type of fracture fixation is limited. This study compared the abilities of four fixation methods to fix metacarpal shaft fractures with wedge-shaped bone defects. METHODS: In total, 28 artificial metacarpal bones were used. To create wedge-shaped bone defects, an electric saw was used to create metacarpal shaft fractures at the midshaft of each bone. The artificial metacarpal bones were then divided into four groups for fixation. The bones in the first group were fixed with a dorsal locked plate (DP group), those in the second group were fixed with a volar locked plate (VP group), and those in the third group were fixed by combining dorsal and volar locked plates (DP + VP group), and those in the fourth group were fixed with two K-wires (2 K group). Cantilever bending tests were conducted using a material testing machine to measure yielding force and stiffness. The four groups' fixation capabilities were then assessed through analysis of variance and Tukey's test. RESULTS: The DP + VP group (164.1±44.0 N) achieved a significantly higher yielding force relative to the 2 K group (50.7 ± 8.9 N); the DP group (13.6 ± 3.0 N) and VP group (12.3 ± 1.0 N) did not differ significantly in terms of yielding force, with both achieving lower yielding forces relative to the DP + VP group and 2 K group. The DP + VP group (19.8±6.3 N/mm) achieved the highest level of stiffness, and the other three groups did not differ significantly in terms of stiffness (2 K group, 5.4 ± 1.1 N/mm; DP group, 4.0 ± 0.9 N/mm; VP group, 3.9 ± 1.9 N/mm). CONCLUSIONS: The fixation method involving the combined use of dorsal and volar locked plates (DP + VP group) resulted in optimal outcomes with respect to fixing metacarpal shaft fractures with volar wedge bone defects.


Subject(s)
Bone Plates , Bone Wires , Fracture Fixation, Internal , Fractures, Bone , Metacarpal Bones , Metacarpal Bones/injuries , Metacarpal Bones/surgery , Humans , Biomechanical Phenomena , Fracture Fixation, Internal/instrumentation , Fracture Fixation, Internal/methods , Fractures, Bone/surgery
SELECTION OF CITATIONS