Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.141
Filter
1.
Otol Neurotol ; 45(5): e435-e442, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38728559

ABSTRACT

OBJECTIVE: This study evaluates the clinical outcomes of 807 percutaneous wide-diameter bone-anchored hearing implants (BAHIs) in 701 patients. In addition, it compares patient groups and examines bone conduction device (BCD) usage. STUDY DESIGN: Retrospective cohort study. Mean follow-up period of 3.8 years. SETTING: Tertiary referral center. PATIENTS: All patients implanted with a percutaneous wide-diameter BAHI until December 2020 were included. Patients were divided into age groups, "loading-time" groups, and, if applicable, specific subgroups thought to be at risk for complications postsurgery, e.g., intellectual disability and comorbidities. MAIN OUTCOME MEASURES: Soft tissue reaction, implant survival, revision surgery, and BCD usage. RESULTS: In 9.1% of the 5,188 observations of 807 implants, an adverse soft tissue reaction was reported according to the Holgers' scale. Significantly more (adverse) soft tissue reactions were observed in children and intellectually disabled (ID) patients (p < 0.05). Comorbidity subgroups showed no significant differences in soft tissue reactions. Implant loss percentage, including explantations, was 6.2%. Implant survival was significantly worse in patients with ID (14.1%; p = 0.021). Pediatric age, early loading, or comorbidities did not significantly influence implant survival. At least 592 implants (73.4%) were used for bone conduction hearing, of which 65.4% were used daily. CONCLUSION: Both children and ID patients are more prone to (adverse) soft tissue reactions, ID patients only have a higher risk of implant loss. The rate of implant loss in children seemed to be reduced compared to previous studies and thus more comparable to adults since using wide-diameter implants.


Subject(s)
Bone Conduction , Bone-Anchored Prosthesis , Hearing Aids , Humans , Male , Female , Retrospective Studies , Adult , Child , Middle Aged , Adolescent , Young Adult , Aged , Child, Preschool , Treatment Outcome , Reoperation/statistics & numerical data , Follow-Up Studies , Aged, 80 and over , Suture Anchors , Postoperative Complications/epidemiology
2.
JASA Express Lett ; 4(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38727569

ABSTRACT

Bimodal stimulation, a cochlear implant (CI) in one ear and a hearing aid (HA) in the other, provides highly asymmetrical inputs. To understand how asymmetry affects perception and memory, forward and backward digit spans were measured in nine bimodal listeners. Spans were unchanged from monotic to diotic presentation; there was an average two-digit decrease for dichotic presentation with some extreme cases of decreases to zero spans. Interaurally asymmetrical decreases were not predicted based on the device or better-functioning ear. Therefore, bimodal listeners can demonstrate a strong ear dominance, diminishing memory recall dichotically even when perception was intact monaurally.


Subject(s)
Cochlear Implants , Humans , Middle Aged , Aged , Male , Female , Dichotic Listening Tests , Adult , Auditory Perception/physiology , Hearing Aids
3.
Otol Neurotol ; 45(5): 556-563, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38693091

ABSTRACT

OBJECTIVE: To investigate the feasibility of early sound processor loading with two separate bone-anchored hearing aid implants 1 to 2 weeks after implantation. Secondary endpoints included registration of any postoperative complications, skin reactions, and any adverse events. STUDY DESIGN: Prospective, nonrandomized, noncontrolled, multicenter clinical trial. SETTING: Tertiary referral center. PATIENTS: Sixty adult patients, eligible for bone-anchored hearing aid surgery, were enrolled. INTERVENTION: Implantation of the bone-anchored hearing aid implants were done using minimally invasive surgery with tissue preservation. MAIN OUTCOME MEASURE: Implant stability quotient (ISQ) values were recorded using resonance frequency analysis. Follow-ups were scheduled 5 to 12 days, 4 to 8 weeks, 6 months, and 12 months postoperatively. Differences between the lowest ISQ values (ISQ low) over time were analyzed by paired-samples t test with a significance level of 0.05. Skin and soft tissue reactions were assessed according to Holger's classification. RESULTS: Loading time of the Ponto Wide implant was 11.6 ± 1.4 days (SD) in average (median, 12 d; range, 7-19 d). Loading of the Ponto BHX implant was done 9.7 ± 3.5 days (SD) postoperatively (median, 9 d; range, 5-19 d). The implant stability increased significantly during the 12-month study period with both implants. One Ponto BHX implant was lost. Skin and soft tissue reactions were few in both groups. Across all planned follow-up visits, no skin and soft tissue reactions were observed in 86% (Ponto BHX implant) and 85% (Ponto Wide implant). CONCLUSION: Very early loading of sound processors after percutaneous bone-anchored hearing system surgery is safe already 1 to 2 weeks postoperatively.


Subject(s)
Hearing Aids , Humans , Male , Female , Middle Aged , Adult , Aged , Prospective Studies , Treatment Outcome , Suture Anchors , Bone-Anchored Prosthesis , Prosthesis Implantation/methods , Young Adult , Aged, 80 and over
4.
Trends Hear ; 28: 23312165241256721, 2024.
Article in English | MEDLINE | ID: mdl-38773778

ABSTRACT

This study aimed to investigate the role of hearing aid (HA) usage in language outcomes among preschool children aged 3-5 years with mild bilateral hearing loss (MBHL). The data were retrieved from a total of 52 children with MBHL and 30 children with normal hearing (NH). The association between demographical, audiological factors and language outcomes was examined. Analyses of variance were conducted to compare the language abilities of HA users, non-HA users, and their NH peers. Furthermore, regression analyses were performed to identify significant predictors of language outcomes. Aided better ear pure-tone average (BEPTA) was significantly correlated with language comprehension scores. Among children with MBHL, those who used HA outperformed the ones who did not use HA across all linguistic domains. The language skills of children with MBHL were comparable to those of their peers with NH. The degree of improvement in audibility in terms of aided BEPTA was a significant predictor of language comprehension. It is noteworthy that 50% of the parents expressed reluctance regarding HA use for their children with MBHL. The findings highlight the positive impact of HA usage on language development in this population. Professionals may therefore consider HAs as a viable treatment option for children with MBHL, especially when there is a potential risk of language delay due to hearing loss. It was observed that 25% of the children with MBHL had late-onset hearing loss. Consequently, the implementation of preschool screening or a listening performance checklist is recommended to facilitate early detection.


Subject(s)
Child Language , Hearing Aids , Hearing Loss, Bilateral , Language Development , Humans , Male , Child, Preschool , Female , Hearing Loss, Bilateral/rehabilitation , Hearing Loss, Bilateral/diagnosis , Hearing Loss, Bilateral/physiopathology , Hearing Loss, Bilateral/psychology , Speech Perception , Case-Control Studies , Correction of Hearing Impairment/instrumentation , Treatment Outcome , Persons With Hearing Impairments/rehabilitation , Persons With Hearing Impairments/psychology , Severity of Illness Index , Comprehension , Hearing , Audiometry, Pure-Tone , Age Factors , Auditory Threshold , Language Tests
5.
J Neural Eng ; 21(3)2024 May 22.
Article in English | MEDLINE | ID: mdl-38729132

ABSTRACT

Objective.This study develops a deep learning (DL) method for fast auditory attention decoding (AAD) using electroencephalography (EEG) from listeners with hearing impairment (HI). It addresses three classification tasks: differentiating noise from speech-in-noise, classifying the direction of attended speech (left vs. right) and identifying the activation status of hearing aid noise reduction algorithms (OFF vs. ON). These tasks contribute to our understanding of how hearing technology influences auditory processing in the hearing-impaired population.Approach.Deep convolutional neural network (DCNN) models were designed for each task. Two training strategies were employed to clarify the impact of data splitting on AAD tasks: inter-trial, where the testing set used classification windows from trials that the training set had not seen, and intra-trial, where the testing set used unseen classification windows from trials where other segments were seen during training. The models were evaluated on EEG data from 31 participants with HI, listening to competing talkers amidst background noise.Main results.Using 1 s classification windows, DCNN models achieve accuracy (ACC) of 69.8%, 73.3% and 82.9% and area-under-curve (AUC) of 77.2%, 80.6% and 92.1% for the three tasks respectively on inter-trial strategy. In the intra-trial strategy, they achieved ACC of 87.9%, 80.1% and 97.5%, along with AUC of 94.6%, 89.1%, and 99.8%. Our DCNN models show good performance on short 1 s EEG samples, making them suitable for real-world applications. Conclusion: Our DCNN models successfully addressed three tasks with short 1 s EEG windows from participants with HI, showcasing their potential. While the inter-trial strategy demonstrated promise for assessing AAD, the intra-trial approach yielded inflated results, underscoring the important role of proper data splitting in EEG-based AAD tasks.Significance.Our findings showcase the promising potential of EEG-based tools for assessing auditory attention in clinical contexts and advancing hearing technology, while also promoting further exploration of alternative DL architectures and their potential constraints.


Subject(s)
Attention , Auditory Perception , Deep Learning , Electroencephalography , Hearing Loss , Humans , Attention/physiology , Female , Electroencephalography/methods , Male , Middle Aged , Hearing Loss/physiopathology , Hearing Loss/rehabilitation , Hearing Loss/diagnosis , Aged , Auditory Perception/physiology , Noise , Adult , Hearing Aids , Speech Perception/physiology , Neural Networks, Computer
7.
Trends Hear ; 28: 23312165241253653, 2024.
Article in English | MEDLINE | ID: mdl-38715401

ABSTRACT

This study aimed to preliminarily investigate the associations between performance on the integrated Digit-in-Noise Test (iDIN) and performance on measures of general cognition and working memory (WM). The study recruited 81 older adult hearing aid users between 60 and 95 years of age with bilateral moderate to severe hearing loss. The Chinese version of the Montreal Cognitive Assessment Basic (MoCA-BC) was used to screen older adults for mild cognitive impairment. Speech reception thresholds (SRTs) were measured using 2- to 5-digit sequences of the Mandarin iDIN. The differences in SRT between five-digit and two-digit sequences (SRT5-2), and between five-digit and three-digit sequences (SRT5-3), were used as indicators of memory performance. The results were compared to those from the Digit Span Test and Corsi Blocks Tapping Test, which evaluate WM and attention capacity. SRT5-2 and SRT5-3 demonstrated significant correlations with the three cognitive function tests (rs ranging from -.705 to -.528). Furthermore, SRT5-2 and SRT5-3 were significantly higher in participants who failed the MoCA-BC screening compared to those who passed. The findings show associations between performance on the iDIN and performance on memory tests. However, further validation and exploration are needed to fully establish its effectiveness and efficacy.


Subject(s)
Cognition , Cognitive Dysfunction , Hearing Aids , Memory, Short-Term , Humans , Aged , Female , Male , Middle Aged , Aged, 80 and over , Memory, Short-Term/physiology , Cognitive Dysfunction/diagnosis , Noise/adverse effects , Speech Perception/physiology , Speech Reception Threshold Test , Age Factors , Persons With Hearing Impairments/psychology , Persons With Hearing Impairments/rehabilitation , Hearing Loss/rehabilitation , Hearing Loss/diagnosis , Hearing Loss/psychology , Mental Status and Dementia Tests , Memory , Acoustic Stimulation , Predictive Value of Tests , Correction of Hearing Impairment/instrumentation , Auditory Threshold
8.
Int J Pediatr Otorhinolaryngol ; 179: 111930, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38579404

ABSTRACT

BACKGROUND: Deaf and hard of hearing (DHH) children may experience communication delays, irrespective of early intervention and technology. Australian Sign Language (Auslan) is one approach in early intervention to address language delays. Current prevalence of Auslan use among Australian families with DHH children is unknown. AIMS: The first aim was to determine the proportion of families enrolled in an Australian statewide hearing loss databank who use Auslan with their DHH child. The second aim was to explore the relationships between indicators of child hearing loss (bilateral or unilateral hearing loss, degree of hearing loss, and device use: hearing aids and cochlear implants), family factors (maternal education, attendance at early intervention, family history of deafness, and socio-economic disadvantage) and the family's reported use of Auslan. METHODS: We analysed the enrolment data from 997 families who participated in an Australian statewide hearing loss databank between 2012 and 2021. We described the proportion of families who used Auslan with their DHH child at home. The association between indicators of child hearing loss and family factors, and the parental reports of communication approach were examined using correlation analyses. RESULTS: Eighty-seven of 997 parents (8.7%) reported using Auslan with their DHH child. Of these, 26 (2.6%) used Auslan as their primary language. The use of Auslan at home was associated with the following indicators of child hearing loss: bilateral hearing loss, profound compared to mild hearing loss, and cochlear implant and hearing aid use compared to no device use. The family factors associated with the use of Auslan were: referral or attendance at early intervention compared to those who did not attend, and a family history of deafness compared to those with none. No association was found between maternal education and socio-economic disadvantage and the use of Auslan. CONCLUSION: This Australian study found a low proportion (8.7%) of families with a DHH child who reported using Auslan. Seven child hearing loss and family factors were considered, and five were significantly associated with using Auslan at home. Children with a greater degree of hearing loss, attendance at early intervention and family history of deafness tended to use Auslan.


Subject(s)
Deafness , Hearing Aids , Hearing Loss , Persons With Hearing Impairments , Child , Humans , Deafness/epidemiology , Deafness/surgery , Deafness/rehabilitation , Australia/epidemiology , Hearing Loss/epidemiology
9.
Cereb Cortex ; 34(4)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38610087

ABSTRACT

Hearing is critical to spoken language, cognitive, and social development. Little is known about how early auditory experiences impact the brain structure of children with bilateral sensorineural hearing loss. This study examined the influence of hearing aid use and residual hearing on the auditory cortex of children with severe to profound congenital sensorineural hearing loss. We evaluated cortical preservation in 103 young pediatric cochlear implant candidates (55 females and 48 males) by comparing their multivoxel pattern similarity of auditory cortical structure with that of 78 age-matched children with typical hearing. The results demonstrated that early-stage hearing aid use preserved the auditory cortex of children with bilateral congenital sensorineural hearing loss. Children with less residual hearing experienced a more pronounced advantage from hearing aid use. However, this beneficial effect gradually diminished after 17 months of hearing aid use. These findings support timely fitting of hearing aids in conjunction with early implantation to take advantage of neural preservation to maximize auditory and spoken language development.


Subject(s)
Auditory Cortex , Hearing Aids , Hearing Loss, Sensorineural , Female , Male , Humans , Child , Hearing Loss, Sensorineural/therapy , Hearing , Brain
10.
Int J Pediatr Otorhinolaryngol ; 180: 111907, 2024 May.
Article in English | MEDLINE | ID: mdl-38688185

ABSTRACT

OBJECTIVE: Stress levels among caregivers of children with hearing loss could influence caregiver-child interactions and ultimately, children's developmental outcomes. Given the limited understanding of stress levels among caregivers of Australian children with hearing loss, the present study aimed to examine stress in caregivers of 5-year-old children with hearing loss wearing hearing aids or cochlear implants and to identify factors associated with greater stress levels. METHODS: A total of 99 caregivers of 70 hearing aid users and 29 cochlear implant users participated in the study. Caregivers' stress was measured using the 68-item Pediatric Hearing Impairment Caregiver Experience (PHICE) questionnaire that examines caregivers' context-specific stress levels in relation to caring for a child with hearing loss. Factors contributing to stress were identified in relation to eight domains including communication, education, emotional well-being, equipment, financial, healthcare, social, and support. RESULTS: Across domains, the three most common predictors of increased stress were the use of cochlear implants over hearing aids, use of sign and oral language (mixed) over oral language as the communication mode at home, and increased behavioural difficulties of the child. CONCLUSION: Overall, reported stress levels among Australian caregivers were low. Identified factors influencing stress levels can inform service provision improvement.


Subject(s)
Caregivers , Cochlear Implants , Hearing Aids , Hearing Loss , Stress, Psychological , Humans , Child, Preschool , Female , Caregivers/psychology , Male , Australia , Hearing Loss/psychology , Surveys and Questionnaires , Adult
11.
Trends Hear ; 28: 23312165241246597, 2024.
Article in English | MEDLINE | ID: mdl-38629486

ABSTRACT

Hearing aids and other hearing devices should provide the user with a benefit, for example, compensate for effects of a hearing loss or cancel undesired sounds. However, wearing hearing devices can also have negative effects on perception, previously demonstrated mostly for spatial hearing, sound quality and the perception of the own voice. When hearing devices are set to transparency, that is, provide no gain and resemble open-ear listening as well as possible, these side effects can be studied in isolation. In the present work, we conducted a series of experiments that are concerned with the effect of transparent hearing devices on speech perception in a collocated speech-in-noise task. In such a situation, listening through a hearing device is not expected to have any negative effect, since both speech and noise undergo identical processing, such that the signal-to-noise ratio at ear is not altered and spatial effects are irrelevant. However, we found a consistent hearing device disadvantage for speech intelligibility and similar trends for rated listening effort. Several hypotheses for the possible origin for this disadvantage were tested by including several different devices, gain settings and stimulus levels. While effects of self-noise and nonlinear distortions were ruled out, the exact reason for a hearing device disadvantage on speech perception is still unclear. However, a significant relation to auditory model predictions demonstrate that the speech intelligibility disadvantage is related to sound quality, and is most probably caused by insufficient equalization, artifacts of frequency-dependent signal processing and processing delays.


Subject(s)
Hearing Aids , Hearing Loss , Speech Perception , Humans , Hearing , Noise/adverse effects
12.
Acta Otorhinolaryngol Ital ; 44(2): 113-119, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38651553

ABSTRACT

Objective: To determine the benefits of binaural hearing rehabilitation in patients with monaural conductive or mixed hearing loss treated with a unilateral bone conduction implant (BCI). Methods: This monocentric study includes 7 patients with monaural conductive or mixed hearing loss who underwent surgical implantation of a unilateral BCI (Bonebridge, Med-El). An ITA Matrix test was performed by each patient included in the study - without and with the BCI and in three different settings - to determine the summation effect, squelch effect and head shadow effect. Subjective hearing benefits were assessed using the Abbreviated Profile of Hearing Aid Benefit (APHAB) questionnaire. Results: The difference in signal to noise ratio of patients without and with BCI was 0.79 dB in the summation setting (p < 0.05), 4.62 dB in the head shadow setting (p < 0.05) and 1.53 dB (p = 0.063) in the squelch setting. The APHAB questionnaire revealed a subjective discomfort in the presence of unexpected sounds in patients using a unilateral BCI (aversiveness score) compared to the same environmental situations without BCI, with a mean discomfort score of 69.00% (SD ± 21.24%) with monaural BCI versus 25.67% (SD ± 16.70%) without BCI (difference: -43.33%, p < 0.05). In terms of global score, patients wearing a unilateral Bonebridge implant did not show any significant differences compared to those without hearing aid (difference: -4.00%, p = 0.310). Conclusions: Our study shows that the use of a unilateral BCI in patients affected by monaural conductive or mixed hearing loss can improve speech perception under noise conditions due to the summation effect and to the decrease of the head shadow effect. However, since monaural BCIs might lead to discomfort under noise conditions in some subjects, a pre-operative assessment of the possible individual benefit of a monaural BCI should be carried out in patients affected by unilateral conductive or mixed hearing loss in order to investigate the possible additional effect of the fitting of hearing aids.


Subject(s)
Bone Conduction , Hearing Loss, Conductive , Hearing Loss, Mixed Conductive-Sensorineural , Humans , Female , Male , Middle Aged , Hearing Loss, Mixed Conductive-Sensorineural/rehabilitation , Hearing Loss, Mixed Conductive-Sensorineural/surgery , Adult , Hearing Loss, Conductive/rehabilitation , Hearing Loss, Conductive/surgery , Hearing Loss, Conductive/physiopathology , Hearing Aids , Aged
13.
J Acoust Soc Am ; 155(4): 2460-2469, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38578178

ABSTRACT

Head-worn devices (HWDs) interfere with the natural transmission of sound from the source to the ears of the listener, worsening their localization abilities. The localization errors introduced by HWDs have been mostly studied in static scenarios, but these errors are reduced if head movements are allowed. We studied the effect of 12 HWDs on an auditory-cued visual search task, where head movements were not restricted. In this task, a visual target had to be identified in a three-dimensional space with the help of an acoustic stimulus emitted from the same location as the visual target. The results showed an increase in the search time caused by the HWDs. Acoustic measurements of a dummy head wearing the studied HWDs showed evidence of impaired localization cues, which were used to estimate the perceived localization errors using computational auditory models of static localization. These models were able to explain the search-time differences in the perceptual task, showing the influence of quadrant errors in the auditory-aided visual search task. These results indicate that HWDs have an impact on sound-source localization even when head movements are possible, which may compromise the safety and the quality of experience of the wearer.


Subject(s)
Hearing Aids , Sound Localization , Acoustic Stimulation , Head Movements
14.
N Engl J Med ; 390(16): 1505-1512, 2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38657246
15.
Trials ; 25(1): 256, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38610038

ABSTRACT

BACKGROUND: Teleaudiology can potentially improve access to hearing healthcare services. Remote hearing aid fittings offer a new mode of service delivery that removes barriers of geography and access to an audiologist. Real-ear measurements (REMs) are the gold standard for hearing aid output verification but require in-clinic appointments. This study will investigate whether remote hearing aid fittings can provide clinically equivalent outcomes when compared to current, in-clinic, best practice guidelines. RESEARCH DESIGN: A repeated measure, double-blinded crossover design will be used. Participants will be randomly allocated to one of two groups to determine order of intervention, balanced for degree of hearing loss. STUDY SAMPLE: Sixty adults with mild to moderate hearing loss and at least 1 year of experience with hearing aids will be recruited. DATA COLLECTION AND ANALYSIS: Participants will complete two hearing aid fitting protocols, one using an in-clinic fitting process and the other using a remote (at-home) fitting process. In-clinic fittings will include REMs with adjustments to standard (NAL-NL2) prescription targets. The two fitting protocols will then be randomly assigned to participants in a crossover design, so participants and researchers will be blinded to the order of the two fitting protocols. Participants will then have a 4-week period with follow-up appointments for participant-directed gain adjustment. For each fitting protocol, participants will complete objective measurements of final hearing aid output with REMs, speech-in-noise testing, subjective measurements of hearing aid performance, and quality of life measurements. They will then begin an identical period of living with, adjusting, and objective assessment with the other fitting protocol. Data will be analysed as repeated measures with statistical control for potential confounding variables. RESULTS: Data will compare the four-frequency average real-ear aided response (4FREAR) for hearing aids programmed in-clinic and hearing aids programmed remotely, after participant-directed gain adjustments. Secondary measures will assess clinically significant differences in estimated speech intelligibility, hearing-related quality of life, hearing aid benefit, sound quality and preference, and speech-in-noise ability. CONCLUSIONS: This study will inform the development of best practice guidelines for remote hearing aid fittings. If no clinically significant differences are found between in-clinic and remote fit hearing aids, it has the potential to expand teleaudiology initiatives. TRIAL REGISTRATION: Australian New Zealand Clinical Trial Registry, ACTRN12623000028606p . Date of registration: 12 January 2023.


Subject(s)
Hearing Aids , Hearing Loss, Sensorineural , Hearing Loss , Adult , Humans , Quality of Life , Australia , Ambulatory Care Facilities , Hearing Loss, Sensorineural/diagnosis , Hearing Loss, Sensorineural/therapy , Randomized Controlled Trials as Topic
16.
Trends Hear ; 28: 23312165241246616, 2024.
Article in English | MEDLINE | ID: mdl-38656770

ABSTRACT

Negativity bias is a cognitive bias that results in negative events being perceptually more salient than positive ones. For hearing care, this means that hearing aid benefits can potentially be overshadowed by adverse experiences. Research has shown that sustaining focus on positive experiences has the potential to mitigate negativity bias. The purpose of the current study was to investigate whether a positive focus (PF) intervention can improve speech-in-noise abilities for experienced hearing aid users. Thirty participants were randomly allocated to a control or PF group (N = 2 × 15). Prior to hearing aid fitting, all participants filled out the short form of the Speech, Spatial and Qualities of Hearing scale (SSQ12) based on their own hearing aids. At the first visit, they were fitted with study hearing aids, and speech-in-noise testing was performed. Both groups then wore the study hearing aids for two weeks and sent daily text messages reporting hours of hearing aid use to an experimenter. In addition, the PF group was instructed to focus on positive listening experiences and to also report them in the daily text messages. After the 2-week trial, all participants filled out the SSQ12 questionnaire based on the study hearing aids and completed the speech-in-noise testing again. Speech-in-noise performance and SSQ12 Qualities score were improved for the PF group but not for the control group. This finding indicates that the PF intervention can improve subjective and objective hearing aid benefits.


Subject(s)
Correction of Hearing Impairment , Hearing Aids , Noise , Persons With Hearing Impairments , Speech Intelligibility , Speech Perception , Humans , Male , Female , Aged , Noise/adverse effects , Middle Aged , Correction of Hearing Impairment/instrumentation , Persons With Hearing Impairments/rehabilitation , Persons With Hearing Impairments/psychology , Perceptual Masking , Hearing Loss/rehabilitation , Hearing Loss/psychology , Hearing Loss/diagnosis , Audiometry, Speech , Surveys and Questionnaires , Aged, 80 and over , Time Factors , Acoustic Stimulation , Hearing , Treatment Outcome
17.
J Am Med Dir Assoc ; 25(5): 853-859, 2024 May.
Article in English | MEDLINE | ID: mdl-38643971

ABSTRACT

OBJECTIVES: Hearing aids have important health benefits for older adults with Alzheimer disease and related dementias (ADRD); however, hearing aid adoption in this group is low. This study aimed to determine where to target hearing aid interventions for American long-term care recipients with ADRD by examining the association of ADRD and residence type with respondent-reported unmet hearing aid need. DESIGN, SETTING, AND PARTICIPANTS: This cross-sectional study used data from the United States National Core Indicators-Aging and Disabilities survey (2015-2019) for long-term care recipients aged ≥65 years. METHODS: We used multivariable logistic regression to model the likelihood of reporting unmet hearing aid need conditional on ADRD status and residence type (own/family house or apartment, residential care, or nursing facility/home), adjusting for sociodemographic factors and response type (self vs proxy). RESULTS: Of the 25,492 respondents [median (IQR) age, 77 (71, 84) years; 7074 (27.8%) male], 5442 (21.4%) had ADRD and 3659 (14.4%) owned hearing aids. Residence types were 17,004 (66.8%) own/family house or apartment, 4966 (19.5%) residential care, and 3522 (13.8%) nursing home. Among non-hearing aid owners, ADRD [adjusted odds ratio (AOR) 0.90, 95% CI 0.80-1.0] and residence type were associated with respondent-reported unmet hearing aid need. Compared to the nursing home reference group, respondents in their own/family home (AOR 1.85, 95% CI 1.61-2.13) and residential care (AOR 1.30, 95% CI 1.10-1.53) were more likely to report unmet hearing aid need. This pattern was significantly more pronounced in people with ADRD than in those without, stemming from an interaction between ADRD and residence type. CONCLUSIONS AND IMPLICATIONS: American long-term care recipients with ADRD living in their own/family home are more likely to report unmet hearing aid need than those with ADRD in institutional and congregate settings. This information can inform the design and delivery of hearing interventions for older adults with ADRD.


Subject(s)
Dementia , Hearing Aids , Humans , Hearing Aids/statistics & numerical data , Aged , Male , Female , United States , Cross-Sectional Studies , Aged, 80 and over , Dementia/therapy , Hearing Loss/therapy , Health Services Needs and Demand , Surveys and Questionnaires , Long-Term Care
18.
Eur Arch Otorhinolaryngol ; 281(6): 2849-2859, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38647685

ABSTRACT

PURPOSE: The indications of Vibrant Soundbridge (VSB) have been expanded to include patients with conductive and mixed hearing loss due to congenital aural atresia (CAA). However, the current evidence supporting the auditory outcomes of VSB is based mainly on case reports and retrospective chart reviews. Therefore, the present systematic review aims to summarize and critically appraise the current evidence regarding the safety and effectiveness of VSB in children and adult patients with CAA. METHODS: A systematic literature search retrieved studies that evaluated the outcomes of unilateral or bilateral implantation of VSB in patients with CAA. The bibliographic search was conducted in PubMed, Scopus, EBSCO, and Cochrane Central Register of Controlled Trials (CENTRAL) databases from January 2000 to December 2022. RESULTS: Twenty-seven studies were included in the present systematic review. Overall, the speech perception after VSB was good, with a mean word recognition score (WRS) score ranging from 60 to 96.7%. The mean postoperative speech recognition threshold (SRT) after implantation ranged from 20.8 to 50 dB. The effective gain was reported in 15 studies, ranging from 31.3 to 45.5 dB. In terms of user satisfaction with VSB, the included studies showed significant improvements in the patient-reported outcomes, such as the Speech Spatial and Qualities of Hearing scale and Glasgow Hearing Aid Benefit Profile. The VSB implantation was generally safe with low incidence of postoperative complications. CONCLUSION: VSB provides significant benefits to individuals with hearing loss owing to CAA, with very good subjective outcomes and a low risk of complications.


Subject(s)
Ear , Ear/abnormalities , Humans , Ear/surgery , Congenital Abnormalities/surgery , Hearing Loss, Conductive/surgery , Hearing Loss, Conductive/congenital , Speech Perception , Hearing Aids , Hearing Loss, Mixed Conductive-Sensorineural/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...