Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 5.680
Filter
1.
Pan Afr Med J ; 47: 83, 2024.
Article in French | MEDLINE | ID: mdl-38737224

ABSTRACT

Uterine rupture is a life-threatening obstetric complication. The purpose of this study was to investigate the epidemiological features, maternal and foetal prognosis and different treatment options for uterine rupture in healthy and scarred uteri. We conducted a retrospective monocentric descriptive and analytical study of 60 cases of uterine rupture collected in the Department of Gynaecology-Obstetrics of the Center of Maternity and Neonatology, Monastir, from 2017 to 2021. Patients were classified according to the presence or absence of a uterine scar. Sixty patients were enrolled in the study. The majority of cases of rupture occurred in patients with scarred uterus (n=55). The most common clinical sign was abnormal foetal heart rate. No maternal deaths were recorded and perinatal mortality rate was 11%. Mean BMI, fetal macrosomia rate and mean parity were significantly higher in the healthy uterus group than in the scarred uterus group (p=0.033, 0.018, and 0.013, respectively). The maternal complications studied (post-partum haemorrhage, hysterectomy, blood transfusion, prolonged hospitalisation) were significantly more frequent in patients with unscarred uterine rupture (p=0.039; p=0.032; p=0.009; p=0.025 respectively). Uterine rupture is a life-threatening obstetrical event for the foetus and the mother. Fetal heart rate abnormality is the most common sign associated with uterine rupture. Management is based on conservative treatment in most cases. Patients with scarred uterus have a better prognosis.


Subject(s)
Postpartum Hemorrhage , Uterine Rupture , Humans , Female , Tunisia/epidemiology , Retrospective Studies , Uterine Rupture/epidemiology , Uterine Rupture/etiology , Adult , Pregnancy , Postpartum Hemorrhage/epidemiology , Postpartum Hemorrhage/therapy , Postpartum Hemorrhage/etiology , Young Adult , Cicatrix , Prognosis , Hysterectomy/statistics & numerical data , Perinatal Mortality , Fetal Macrosomia/epidemiology , Infant, Newborn , Heart Rate, Fetal , Blood Transfusion/statistics & numerical data , Length of Stay/statistics & numerical data
2.
Bull Exp Biol Med ; 176(5): 533-538, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38722506

ABSTRACT

We performed a comparative analysis of direct and mediated through the maternal organism effects of elevated catecholamine concentration on changes in the cardiac activity parameters in female rats and their fetuses on gestation days 18 and 20 under in vivo conditions. Administration of L-DOPA, a precursor of catecholaminergic transmitters, did not cause chronotropic effects in fetuses. Analysis of HR variability showed that in fetuses, irrespective of the administration route, there was an increase in nervous influences while the leading role of humoral-metabolic factors in the regulation of HR was preserved. In females receiving L-DOPA injection on day 18 of gestation, a decrease in humoral-metabolic and an increase in nerve effects were observed; in rats injected with L-DOPA on day 20 of gestation, an increase in sympathetic influences was found. Administration of L-DOPA to fetuses provoked a slight increase in the power of all components of the heart rhythm periodogram spectrum in females on day 18 of gestation and their decrease on day 20. Changes in the parameters of HR variability in females can confirm the hypothesis that in the "mother-fetus" system, the heart rhythm in the mother can be affected by both maternal and fetal influences presumably through the humoral-metabolic regulation.


Subject(s)
Catecholamines , Fetus , Levodopa , Animals , Female , Rats , Pregnancy , Levodopa/pharmacology , Catecholamines/metabolism , Fetus/metabolism , Fetus/drug effects , Heart Rate/drug effects , Heart Rate/physiology , Rats, Wistar , Heart Rate, Fetal/drug effects , Heart Rate, Fetal/physiology
3.
Sci Total Environ ; 931: 172730, 2024 Jun 25.
Article in English | MEDLINE | ID: mdl-38663596

ABSTRACT

BACKGROUND: Heat exposure during pregnancy can increase the risk of preterm birth (PTB) through a range of potential mechanisms including pregnancy complications, hormone secretion and infections. However, current research mainly focuses on the effect of heat exposure on pathophysiological pathways of pregnant women, but ignore that maternal heat exposure can also cause physiological changes to the fetus, which will affect the risk of PTB. OBJECTIVE: In this study, we aimed to explore the mediating role of fetal heart rate (FHR) in the relationship between maternal heat exposure and PTB incidence. METHODS: We assigned heat exposure to a multi-center birth cohort in China during 2015-2018, which included all 162,407 singleton live births with several times FHR measurements during the second and third trimesters. We examined the associations between heat exposure, FHR and PTB in the entire pregnancy, each trimester and the last gestational month. The inverse odds ratio-weighted approach applied to the Cox regression was used to identify the mediation effect of heat exposure on PTB and its clinical subtypes via FHR. FINDINGS: Exposure to heat significantly increased the risk of PTB during the third trimester and the entire pregnancy, hazard ratios and 95 % CIs were 1.266 (1.161, 1.379) and 1.328 (1.218, 1.447). Heat exposure during the third trimester and entire pregnancy increased FHR in the third trimester by 0.24 bpm and 0.14 bpm. The proportion of heat exposure mediated by FHR elevation on PTB and its subtype ranged from 3.68 % to 24.06 %, with the significant mediation effect found for both medically indicated PTB and spontaneous PTB. CONCLUSIONS: This study suggests that heat exposure during pregnancy has an important impact on fetal health, and FHR, as a surrogate marker of fetal physiology, may mediate the increased risk of PTB caused by extreme heat. Monitoring and managing physiological changes in the fetus would constitute a promising avenue to reduce adverse birth outcomes associated with maternal heat exposure.


Subject(s)
Hot Temperature , Maternal Exposure , Premature Birth , Female , Humans , Pregnancy , Premature Birth/epidemiology , China/epidemiology , Hot Temperature/adverse effects , Maternal Exposure/statistics & numerical data , Adult , Heart Rate, Fetal/physiology , Risk Factors , Cohort Studies , Infant, Newborn
5.
Glob Health Action ; 17(1): 2328894, 2024 Dec 31.
Article in English | MEDLINE | ID: mdl-38577869

ABSTRACT

BACKGROUND: Globally, every year, approximately 1 million foetal deaths take place during the intrapartum period, fetal heart monitoring (FHRM) and timely intervention can reduce these deaths. OBJECTIVE: This study evaluates the implementation barriers and facilitators of a device, Moyo for FHRM. METHODS: The study adopted a qualitative study design in four hospitals in Nepal where Moyo was implemented for HRM. The study participants were labour room nurses and convenience sampling was used to select them. A total of 20 interviews were done to reach the data saturation. The interview transcripts were translated to English, and qualitative content analysis using deductive approach was applied. RESULTS: Using the deductive approach, the data were organised into three categories i) changes in practice of FHRM, ii) barriers to implementing Moyo and iii) facilitators of implementing Moyo. Moyo improved adherence to intermittent FHRM as the device could handle higher caseloads compared to the previous devices. The implementation of Moyo was hindered by difficulty to organise training ondevice during non-working hours, technical issue of the device, nurse mistrust towards the device and previous experience of poor implementation to similar innovations. Facilitators for implementation included effective training on how to use Moyo, improvement in intrapartum foetal monitoring and improvement in staff morale, ease of using the device, Plan Do Study Act (PDSA) meetings to improve use of Moyo and supportive leadership. CONCLUSION: The change in FHRM practice suggests that the implementation of innovative solution such as Moyo was successful with adequate facilitation, supportive staff attitude and leadership.


Main findings: Before the Moyo implementation, foetal heart rate monitoring was sub-optimal in the hospitals, which changed after introduction of the device, as it helped early display of foetal heart rate in the monitor and supported communication with women during the labour and delivery.Added knowledge: Implementation of Moyo in low-resource setting requires an interdisciplinary approach with continuous support to health care providers on how to correctly read Moyo, maintenance of device and management of false reading.Global health impact for policy and action: The global efforts to accelerate reduce preventable intrapartum related neonatal death requires contextual understanding of clinical context for effective implementation of Moyo.


Subject(s)
Heart Rate, Fetal , Labor, Obstetric , Pregnancy , Female , Humans , Nepal , Heart Rate, Fetal/physiology , Parturition , Hospitals, Public , Qualitative Research
6.
Comput Methods Programs Biomed ; 249: 108145, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38582038

ABSTRACT

BACKGROUND AND OBJECTIVE: Obstetricians use Cardiotocography (CTG), which is the continuous recording of fetal heart rate and uterine contraction, to assess fetal health status. Deep learning models for intelligent fetal monitoring trained on extensively labeled and identically distributed CTG records have achieved excellent performance. However, creation of these training sets requires excessive time and specialist labor for the collection and annotation of CTG signals. Previous research has demonstrated that multicenter studies can improve model performance. However, models trained on cross-domain data may not generalize well to target domains due to variance in distribution among datasets. Hence, this paper conducted a multicenter study with Deep Semi-Supervised Domain Adaptation (DSSDA) for intelligent interpretation of antenatal CTG signals. This approach helps to align cross-domain distribution and transfer knowledge from a label-rich source domain to a label-scarce target domain. METHODS: We proposed a DSSDA framework that integrated Minimax Entropy and Domain Invariance (DSSDA-MMEDI) to reduce inter-domain gaps and thus achieve domain invariance. The networks were developed using GoogLeNet to extract features from CTG signals, with fully connected, softmax layers for classification. We designed a Dynamic Gradient-driven strategy based on Mutual Information (DGMI) to unify the losses from Minimax Entropy (MME), Domain Invariance (DI), and supervised cross-entropy during iterative learning. RESULTS: We validated our DSSDA model on two datasets collected from collaborating healthcare institutions and mobile terminals as the source and target domains, which contained 16,355 and 3,351 CTG signals, respectively. Compared to the results achieved with deep learning networks without DSSDA, DSSDA-MMEDI significantly improved sensitivity and F1-score by over 6%. DSSDA-MMEDI also outperformed other state-of-the-art DSSDA approaches for CTG signal interpretation. Ablation studies were performed to determine the unique contribution of each component in our DSSDA mechanism. CONCLUSIONS: The proposed DSSDA-MMEDI is feasible and effective for alignment of cross-domain data and automated interpretation of multicentric antenatal CTG signals with minimal annotation cost.


Subject(s)
Cardiotocography , Fetal Monitoring , Pregnancy , Female , Humans , Cardiotocography/methods , Entropy , Fetal Monitoring/methods , Uterine Contraction , Heart Rate, Fetal/physiology
7.
J Matern Fetal Neonatal Med ; 37(1): 2345855, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38679588

ABSTRACT

INTRODUCTION: Intraamniotic infection (IAI) and subsequent early-onset neonatal sepsis (EONS) are among the main complications associated with preterm prelabor rupture of membranes (PPROM). Currently used diagnostic tools have been shown to have poor diagnostic performance for IAI. This study aimed to investigate whether the exposure to IAI before delivery is associated with short-term variation of the fetal heart rate in pregnancies with PPROM. METHODS: Observational cohort study of 678 pregnancies with PPROM, delivering between 24 + 0 and 33 + 6 gestational weeks from 2012 to 2019 in five labor units in Stockholm County, Sweden. Electronic medical records were examined to obtain background and exposure data. For the exposure IAI, we used the later diagnosis of EONS in the offspring as a proxy. EONS is strongly associated to IAI and was considered a better proxy for IAI than the histological diagnosis of acute chorioamnionitis, since acute chorioamnionitis can be observed in the absence of both positive microbiology and biochemical markers for inflammation. Cardiotocography traces were analyzed by a computerized algorithm for short-term variation of the fetal heart rate, which was the main outcome measure. RESULTS: Twenty-seven pregnancies were categorized as having an IAI, based on the proxy diagnosis of EONS after birth. Fetuses exposed to IAI had significantly lower short-term variation values in the last cardiotocography trace before birth than fetuses who were not exposed (5.25 vs 6.62 ms; unadjusted difference: -1.37, p = 0.009). After adjustment for smoking and diabetes, this difference remained significant. IAI with a later positive blood culture in the neonate (n = 12) showed an even larger absolute difference in STV (-1.65; p = 0.034), with a relative decrease of 23.5%. CONCLUSION: In pregnancies with PPROM, fetuses exposed to IAI with EONS as a proxy have lower short-term variation of the fetal heart rate than fetuses who are not exposed. Short-term variation might be useful as adjunct surveillance in pregnancies with PPROM.


Subject(s)
Cardiotocography , Fetal Membranes, Premature Rupture , Heart Rate, Fetal , Humans , Female , Pregnancy , Heart Rate, Fetal/physiology , Fetal Membranes, Premature Rupture/diagnosis , Adult , Infant, Newborn , Chorioamnionitis/diagnosis , Cohort Studies , Sweden/epidemiology , Neonatal Sepsis/diagnosis , Pregnancy Complications, Infectious/diagnosis , Gestational Age
8.
Comput Biol Med ; 172: 108220, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38489990

ABSTRACT

INTRODUCTION: Uterine contractions during labour constrict maternal blood flow and oxygen delivery to the developing baby, causing transient hypoxia. While most babies are physiologically adapted to withstand such intrapartum hypoxia, those exposed to severe hypoxia or with poor physiological reserves may experience neurological injury or death during labour. Cardiotocography (CTG) monitoring was developed to identify babies at risk of hypoxia by detecting changes in fetal heart rate (FHR) patterns. CTG monitoring is in widespread use in intrapartum care for the detection of fetal hypoxia, but the clinical utility is limited by a relatively poor positive predictive value (PPV) of an abnormal CTG and significant inter and intra observer variability in CTG interpretation. Clinical risk and human factors may impact the quality of CTG interpretation. Misclassification of CTG traces may lead to both under-treatment (with the risk of fetal injury or death) or over-treatment (which may include unnecessary operative interventions that put both mother and baby at risk of complications). Machine learning (ML) has been applied to this problem since early 2000 and has shown potential to predict fetal hypoxia more accurately than visual interpretation of CTG alone. To consider how these tools might be translated for clinical practice, we conducted a review of ML techniques already applied to CTG classification and identified research gaps requiring investigation in order to progress towards clinical implementation. MATERIALS AND METHOD: We used identified keywords to search databases for relevant publications on PubMed, EMBASE and IEEE Xplore. We used Preferred Reporting Items for Systematic Review and Meta-Analysis for Scoping Reviews (PRISMA-ScR). Title, abstract and full text were screened according to the inclusion criteria. RESULTS: We included 36 studies that used signal processing and ML techniques to classify CTG. Most studies used an open-access CTG database and predominantly used fetal metabolic acidosis as the benchmark for hypoxia with varying pH levels. Various methods were used to process and extract CTG signals and several ML algorithms were used to classify CTG. We identified significant concerns over the practicality of using varying pH levels as the CTG classification benchmark. Furthermore, studies needed to be more generalised as most used the same database with a low number of subjects for an ML study. CONCLUSION: ML studies demonstrate potential in predicting fetal hypoxia from CTG. However, more diverse datasets, standardisation of hypoxia benchmarks and enhancement of algorithms and features are needed for future clinical implementation.


Subject(s)
Cardiotocography , Labor, Obstetric , Female , Humans , Pregnancy , Cardiotocography/methods , Fetal Hypoxia/diagnosis , Heart Rate, Fetal/physiology , Uterine Contraction
9.
Midwifery ; 132: 103952, 2024 May.
Article in English | MEDLINE | ID: mdl-38442530

ABSTRACT

AIM: This study aimed to explore student midwives' theoretical knowledge of intrapartum intermittent auscultation, their confidence in, and their experience of this mode of fetal monitoring. DESIGN AND SETTING: An online cross-section survey with closed and open questions. Descriptive statistics were used to analyse participants' intermittent auscultation knowledge, confidence, and experience. Reflexive thematic analysis was used to identify patterns within the free text about participants' experiences. PARTICIPANTS: Undergraduate midwifery students (n = 303) from Nursing and Midwifery Council-approved educational institutions within the United Kingdom. FINDINGS: Most participants demonstrated good theoretical knowledge. They had witnessed the technique being used in clinical practice, and when performed, the practice was reported to be in line with national guidance. In closed questions, participants reported feeling confident in their intermittent auscultation skills; however, these data contrasted with free-text responses. CONCLUSION: This cross-sectional survey found that student midwives possess adequate knowledge of intermittent auscultation. However, reflecting individual clinical experiences, their confidence in their ability to perform intermittent auscultation varied. A lack of opportunity to practice intermittent auscultation, organisational culture, and midwives' preferences have caused student midwives to question their capabilities with this essential clinical skill, leaving some with doubt about their competency close to registration.


Subject(s)
Clinical Competence , Students, Nursing , Humans , Cross-Sectional Studies , Female , United Kingdom , Students, Nursing/statistics & numerical data , Students, Nursing/psychology , Surveys and Questionnaires , Adult , Clinical Competence/standards , Clinical Competence/statistics & numerical data , Pregnancy , Nurse Midwives/statistics & numerical data , Nurse Midwives/education , Nurse Midwives/psychology , Heart Rate, Fetal/physiology , Midwifery/education , Midwifery/methods , Midwifery/statistics & numerical data , Education, Nursing, Baccalaureate/methods , Auscultation/methods , Auscultation/statistics & numerical data , Auscultation/standards
10.
J Perinat Med ; 52(4): 399-405, 2024 May 27.
Article in English | MEDLINE | ID: mdl-38404246

ABSTRACT

OBJECTIVES: This study aims to show the relation between biomarkers in maternal and cord-blood samples and fetal heart rate variability (fHRV) metrics through a non-invasive fetal magnetocardiography (fMCG) technique. METHODS: Twenty-three women were enrolled for collection of maternal serum and fMCG tracings immediately prior to their scheduled cesarean delivery. The umbilical cord blood was collected for measurement of biomarker levels. The fMCG metrics were then correlated to the biomarker levels from the maternal serum and cord blood. RESULTS: Brain-derived neurotrophic factor (BDNF) had a moderate correlation with fetal parasympathetic activity (0.416) and fetal sympathovagal ratios (-0.309; -0.356). Interleukin (IL)-6 also had moderate-sized correlations but with an inverse relationship as compared to BDNF. These correlations were primarily in cord-blood samples and not in the maternal blood. CONCLUSIONS: In this small sample-sized exploratory study, we observed a moderate correlation between fHRV and cord-blood BDNF and IL-6 immediately preceding scheduled cesarean delivery at term. These findings need to be validated in a larger population.


Subject(s)
Biomarkers , Brain-Derived Neurotrophic Factor , Fetal Blood , Heart Rate, Fetal , Interleukin-6 , Humans , Female , Pregnancy , Brain-Derived Neurotrophic Factor/blood , Heart Rate, Fetal/physiology , Adult , Biomarkers/blood , Fetal Blood/metabolism , Fetal Blood/chemistry , Interleukin-6/blood , Magnetocardiography/methods , Cesarean Section
11.
J Obstet Gynecol Neonatal Nurs ; 53(3): e10-e48, 2024 May.
Article in English | MEDLINE | ID: mdl-38363241

ABSTRACT

Intermittent auscultation (IA) is an evidence-based method of fetal surveillance during labor for birthing people with low-risk pregnancies. It is a central component of efforts to reduce the primary cesarean rate and promote vaginal birth (American College of Obstetricians and Gynecologists, 2019; Association of Women's Health, Obstetric and Neonatal Nurses, 2022a). The use of intermittent IA decreased with the introduction of electronic fetal monitoring, while the increased use of electronic fetal monitoring has been associated with an increase of cesarean births. This practice monograph includes information on IA techniques; interpretation and documentation; clinical decision-making and interventions; communication; education, staffing, legal issues; and strategies to implement IA.


Subject(s)
Fetal Monitoring , Heart Rate, Fetal , Humans , Female , Pregnancy , Heart Rate, Fetal/physiology , Fetal Monitoring/methods , Heart Auscultation/methods , Auscultation/methods , Cardiotocography/methods , Cardiotocography/standards
12.
Nurs Womens Health ; 28(2): e1-e39, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38363259

ABSTRACT

Intermittent auscultation (IA) is an evidence-based method of fetal surveillance during labor for birthing people with low-risk pregnancies. It is a central component of efforts to reduce the primary cesarean rate and promote vaginal birth (American College of Obstetricians and Gynecologists, 2019; Association of Women's Health, Obstetric and Neonatal Nurses, 2022a). The use of intermittent IA decreased with the introduction of electronic fetal monitoring, while the increased use of electronic fetal monitoring has been associated with an increase of cesarean births. This practice monograph includes information on IA techniques; interpretation and documentation; clinical decision-making and interventions; communication; education, staffing, legal issues; and strategies to implement IA.


Subject(s)
Fetal Monitoring , Labor, Obstetric , Pregnancy , Infant, Newborn , Female , Humans , Fetal Monitoring/methods , Heart Rate, Fetal , Auscultation/methods , Cardiotocography/methods
13.
Eur J Obstet Gynecol Reprod Biol ; 295: 75-85, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38340594

ABSTRACT

OBJECTIVE: To assess whether artificial intelligence, inspired by clinical decision-making procedures in delivery rooms, can correctly interpret cardiotocographic tracings and distinguish between normal and pathological events. STUDY DESIGN: A method based on artificial intelligence was developed to determine whether a cardiotocogram shows a normal response of the fetal heart rate to uterine activity (UA). For a given fetus and given the UA and previous FHR, the method predicts a fetal heart rate response, under the assumption that the fetus is still in good condition and based on how that specific fetus has responded so far. We hypothesize that this method, when having only learned from fetuses born in good condition, is incapable of predicting the response of a compromised fetus or an episode of transient fetal distress. The (in)capability of the method to predict the fetal heart rate response would then yield a method that can help to assess fetal condition when the obstetrician is in doubt. Cardiotocographic data of 678 deliveries during labor were selected based on a healthy outcome just after birth. The method was trained on the cardiotocographic data of 548 fetuses of this group to learn their heart rate response. Subsequently it was evaluated on 87 fetuses, by assessing whether the method was able to predict their heart rate responses. The remaining 43 cardiotocograms were segment-by-segment annotated by three experienced gynecologists, indicating normal, suspicious, and pathological segments, while having access to the full recording and neonatal outcome. This future knowledge makes the expert annotations of a quality that is unachievable during live interpretation. RESULTS: The comparison between abnormalities detected by the method (only using past and present input) and the annotated CTG segments by gynecologists (also looking at future input) yields an area under the curve of 0.96 for the distinction between normal and pathological events in majority-voted annotations. CONCLUSION: The developed method can distinguish between normal and pathological events in near real-time, with a performance close to the agreement between three gynecologists with access to the entire CTG tracing and fetal outcome. The method has a strong potential to support clinicians in assessing fetal condition in clinical practice.


Subject(s)
Fetal Diseases , Labor, Obstetric , Pregnancy , Female , Infant, Newborn , Humans , Cardiotocography/methods , Artificial Intelligence , Labor, Obstetric/physiology , Prenatal Care , Heart Rate, Fetal/physiology
15.
BMC Pregnancy Childbirth ; 24(1): 136, 2024 Feb 14.
Article in English | MEDLINE | ID: mdl-38355457

ABSTRACT

BACKGROUND: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor. MATERIAL AND METHODS: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively. RESULTS: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63). CONCLUSIONS: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.


Subject(s)
Cardiotocography , Fetal Hypoxia , Pregnancy , Infant, Newborn , Female , Humans , Cardiotocography/methods , Fetal Hypoxia/diagnosis , Observer Variation , Reproducibility of Results , Cross-Sectional Studies , Heart Rate, Fetal
16.
Reprod Sci ; 31(5): 1401-1407, 2024 May.
Article in English | MEDLINE | ID: mdl-38253982

ABSTRACT

Fetal acidosis among low-risk pregnancies is not common; however, identifying those at risk for this complication antenatally is of great interest. We aimed to assess the correlation between the total decelerations area during the last 120 min of fetal monitoring prior to delivery and neonatal acidemia in low-risk pregnancies and whether the total acceleration area has a protective effect in the presence of decelerations. A retrospective cohort study was conducted among women with term low-risk pregnancies. A researcher blinded to fetal outcomes interpreted electronic fetal monitor patterns during the 120 min prior to delivery. The primary outcome was fetal acidemia, defined as umbilical artery pH below 7.10. The correlation between the total decelerations and accelerations areas and cord blood pH was tested using the Spearman correlation coefficient. A total of 109 women were included and of these, six (5.5%) delivered infants with cord blood pH < 7.10. A significant correlation was demonstrated between the total decelerations area and cord blood pH (p = 0.01). No correlation was found between the total accelerations area and cord blood pH. Among low-risk pregnancies, a correlation was found between the total decelerations area but not the total accelerations area during the final 120 min of labor and cord blood pH.


Subject(s)
Acidosis , Fetal Blood , Humans , Female , Fetal Blood/chemistry , Fetal Blood/metabolism , Pregnancy , Hydrogen-Ion Concentration , Retrospective Studies , Adult , Acidosis/blood , Acidosis/physiopathology , Infant, Newborn , Heart Rate, Fetal/physiology , Cardiotocography , Fetal Monitoring/methods
17.
Acta Obstet Gynecol Scand ; 103(5): 980-991, 2024 May.
Article in English | MEDLINE | ID: mdl-38229258

ABSTRACT

INTRODUCTION: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring. MATERIAL AND METHODS: Non-critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon-FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon-Beltless, Demcon Dipha-16 and Dräger Infinity-M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self-made questionnaire. RESULTS: A total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: -9.7 - 10.7 BPM, regression line: y = -0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon-FM30 received the same FIGO classification. Comparable results were found with the Avalon-Beltless from 36 weeks of gestation, whereas the Dipha-16 and Infinity-M300 performed significantly worse. The Avalon-Beltless, Nemo and Infinity-M300 closely matched the performance of the Avalon-FM30 for maternal heart rate, whereas the performance of the Dipha-16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices. CONCLUSIONS: Both Nemo and Avalon-Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks' gestation, the Avalon-Beltless performs less well, comparable to the Dipha-16 and Infinity-M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.


Subject(s)
Cardiotocography , Heart Rate Determination , Pregnancy , Female , Humans , Cardiotocography/methods , Fetal Monitoring/methods , Electrocardiography , Heart Rate, Fetal/physiology , Patient Outcome Assessment
18.
Am J Obstet Gynecol ; 230(4): 379.e1-379.e12, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38272284

ABSTRACT

BACKGROUND: Intrapartum cardiotocographic monitoring of fetal heart rate by abdominal external ultrasound transducer without simultaneous maternal heart rate recording has been associated with increased risk of early neonatal death and other asphyxia-related neonatal outcomes. It is unclear, however, whether this increase in risk is independently associated with fetal surveillance method or is attributable to other factors. OBJECTIVE: This study aimed to compare different fetal surveillance methods and their association with adverse short- and long-term fetal and neonatal outcomes in a large retrospective cohort of spontaneous term deliveries. STUDY DESIGN: Fetal heart rate and maternal heart rate patterns were recorded by cardiotocography during labor in spontaneous term singleton cephalic vaginal deliveries in the Hospital District of Helsinki and Uusimaa, Finland between October 1, 2005, and September 30, 2023. According to the method of cardiotocography monitoring at birth, the cohort was divided into the following 3 groups: women with ultrasound transducer, women with both ultrasound transducer and maternal heart rate transducer, and women with internal fetal scalp electrode. Umbilical artery pH and base excess values, low 1- and 5-minute Apgar scores, need for intubation and resuscitation, neonatal intensive care unit admission for asphyxia, neonatal encephalopathy, and early neonatal death were used as outcome variables. RESULTS: Among the 213,798 deliveries that met the inclusion criteria, the monitoring type was external ultrasound transducer in 81,559 (38.1%), both external ultrasound transducer and maternal heart rate recording in 62,268 (29.1%), and fetal scalp electrode in 69,971 (32.7%) cases, respectively. The rates of both neonatal encephalopathy (odds ratio, 1.48; 95% confidence interval, 1.08-2.02) and severe acidemia (umbilical artery pH <7.00 and/or umbilical artery base excess ≤-12.0 mmol/L) (odds ratio, 2.03; 95% confidence interval, 1.65-2.50) were higher in fetuses of women with ultrasound transducer alone compared with those of women with concurrent external fetal and maternal heart rate recording. Monitoring with ultrasound transducer alone was also associated with increased risk of neonatal intubation for resuscitation (odds ratio, 1.22; 95% confidence interval, 1.03-1.44). A greater risk of severe neonatal acidemia was observed both in the ultrasound transducer (odds ratio, 2.78; 95% confidence interval, 2.23-3.48) and concurrent ultrasound transducer and maternal heart rate recording (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) groups compared with those monitored with fetal scalp electrodes. No difference in risk of neonatal encephalopathy was found between newborns monitored with concurrent ultrasound transducer and maternal heart rate recording and those monitored with fetal scalp electrodes. CONCLUSION: The use of external ultrasound transducer monitoring of fetal heart rate without simultaneous maternal heart rate recording is associated with higher rates of neonatal encephalopathy and severe neonatal acidemia. We suggest that either external fetal heart rate monitoring with concurrent maternal heart rate recording or internal fetal scalp electrode be used routinely as a fetal surveillance tool in term deliveries.


Subject(s)
Brain Diseases , Infant, Newborn, Diseases , Perinatal Death , Pregnancy , Infant, Newborn , Female , Humans , Cardiotocography/methods , Retrospective Studies , Asphyxia , Heart Rate, Fetal/physiology
19.
Heart Rhythm ; 21(5): 600-609, 2024 May.
Article in English | MEDLINE | ID: mdl-38266752

ABSTRACT

BACKGROUND: The motion relationship and time intervals of the pulsed-wave Doppler (PWD) spectrum are essential for diagnosing fetal arrhythmia. However, few technologies currently are available to automatically calculate fetal cardiac time intervals (CTIs). OBJECTIVE: The purpose of this study was to develop a fetal heart rhythm intelligent quantification system (HR-IQS) for the automatic extraction of CTIs and establish the normal reference range for fetal CTIs. METHODS: A total of 6498 PWD spectrums of 2630 fetuses over the junction between the left ventricular inflow and outflow tracts were recorded across 14 centers. E, A, and V waves were manually labeled by 3 experienced fetal cardiologists, with 17 CTIs extracted. Five-fold cross-validation was performed for training and testing of the deep learning model. Agreement between the manual and HR-IQS-based values was evaluated using the intraclass correlation coefficient and Spearman's rank correlation coefficient. The Jarque-Bera test was applied to evaluate the normality of CTIs' distributions, and the normal reference range of 17 CTIs was established with quantile regression. Arrhythmia subset was compared with the non-arrhythmia subset using the Mann-Whitney U test. RESULTS: Significant positive correlation (P <.001) and moderate-to-excellent consistency (P <.001) between the manual and HR-IQS automated measurements of CTIs was found. The distribution of CTIs was non-normal (P <.001). The normal range (2.5th to 97.5th percentiles) was successfully established for the 17 CTIs. CONCLUSIONS: Using our HR-IQS is feasible for the automated calculation of CTIs in practice and thus could provide a promising tool for the assessment of fetal rhythm and function.


Subject(s)
Arrhythmias, Cardiac , Fetal Heart , Heart Rate, Fetal , Humans , Female , Prospective Studies , Pregnancy , Heart Rate, Fetal/physiology , Arrhythmias, Cardiac/diagnosis , Arrhythmias, Cardiac/physiopathology , Fetal Heart/diagnostic imaging , Fetal Heart/physiology , Gestational Age , Ultrasonography, Prenatal/methods
20.
Infant Ment Health J ; 45(2): 153-164, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38192018

ABSTRACT

Lower fetal heart rate variability (FHRV) may be a prenatal endophenotypic susceptibility marker and increase the impact of both positive and negative coparenting on infant regulatory capacity. This study analyzed the moderator role of FHRV in the association between positive and negative coparenting and infant regulatory capacity at 3 months. The sample comprised 86 first-born infants and their mothers and fathers recruited at a public Health Service in Northern Portugal. FHRV was recorded during routine cardiotocography examination at the third trimester of gestation. Mothers and fathers reported on coparenting and infant regulatory capacity at 2 weeks and 3 months postpartum. FHRV moderated the association between mother's and father's negative coparenting at 2 weeks postpartum and infant regulatory capacity at three months. Infants with low FHRV presented higher regulatory capacity when mothers or fathers reported less negative coparenting, while lower regulatory capacity when mothers or fathers reported more negative coparenting, than infants with high FHRV. Findings suggested lower FHRV as a prenatal endophenotypic susceptibility marker that increases the impact of negative coparenting on infant regulatory capacity.


La más baja variabilidad del pulso cardíaco fetal (FHRV) pudiera ser un marcador determinante de la susceptibilidad endofenotípica prenatal y aumentar el impacto de la crianza compartida tanto positiva como negativa sobre la capacidad regulatoria del infante. Este estudio analizó el papel moderador de FHRV en la asociación entre la positiva y negativa crianza compartida y la capacidad regulatoria del infante a los tres meses. El grupo muestra estaba compuesto de 86 infantes primerizos y sus mamás y papás. Se grabó la FHRV durante una examinación de cardiotocografía de rutina en el tercer trimestre de la gestación. Las mamás y los papás reportaron acerca de la crianza compartida y la capacidad regulatoria del infante a las dos semanas y a los tres meses después del parto. La FHRV moderó la asociación entre la crianza compartida negativa de la mamá y del papá a las dos semanas después del parto y la capacidad regulatoria del infante a los tres meses. Los infantes con baja FHRV presentaron una capacidad regulatoria más alta cuando las mamás o los papás reportaron una crianza compartida menos negativa, mientras que la capacidad regulatoria más baja se dio cuando las mamás o los papás reportaron una crianza compartida más negativa, que los infantes con una FHRV alta. Los resultados señalan la más baja FHRV como un marcador determinante de la susceptibilidad endofenotípica prenatal que aumenta el impacto de la crianza compartida negativa sobre la capacidad regulatoria del infante. Los infantes con baja FHRV pueden ser aquellos que mejor desarrollan mecanismos de autorregulación en la presencia de una crianza compartida menos negativa, mientras que están bajo alto riesgo de problemas regulatorios en la presencia de una crianza compartida más negativa.


Une variabilité de la fréquence cardiaque fœtale (VFCF) plus basse pourrait être un marqueur de sensibilité endophénotypique prénatale et augmenter l'impact du coparentage positif et négatif sur la capacité régulatoire du nourrisson. Cette étude a analysé le rôle modérateur de la VFCF dans le lien entre le coparentage positif et négatif et la capacité régulatoire du nourrisson à trois mois. Cet échantillon a inlu 86 nourrisson premiers nés et leurs mères et pères. La VFCF a été enregistrée penfdant un examen de cardiotocographie de routine au troisième trimestre de la grossesse. Les mères et les pères ont fait état de leur coparentage et de la capacité régulatoire du nourrisson à deux semaines et à trois mois postpartum. La VFCF a modéré le lien entre le coparentage négatif de la mère et du père à deux mois postpartum et la capacité régulatoire du nourrisson à trois mois. Les nourrissons avec une VFCF basse ont présenté une capacité régulatoire plus élevée lorsque les mères ou les pères ont signalé moins de coparentage négatif, alors qu'ils ont présenté une capacité régulatoire plus basse lorsque les mères ou les pères ont signalé un coparentage plus négatif, que les nourrissons avec une VFCF élevée. Les résultats ont suggéré une VFCF plus basse comme un marqueur de sensibilité endophénotypique prénatale qui augmente l'impact de coparentage négatif sur la capacité régulatoire du nourrisson. Les enfants avec une VFCF basse peuvent être ceux qui développent mieux leurs mécanismes auto-régulatoires en présence de moins de coparentage négatif, tout en étant à haut risque de problèmes régulatoires en présence de plus de coparentage négatif.


Subject(s)
Fathers , Parenting , Male , Female , Infant , Humans , Pregnancy , Heart Rate, Fetal , Mothers , Postpartum Period
SELECTION OF CITATIONS
SEARCH DETAIL
...