Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 188
Filter
1.
Pain Res Manag ; 2024: 6866549, 2024.
Article in English | MEDLINE | ID: mdl-39145150

ABSTRACT

Background: The effect of transcutaneous electrical nerve stimulation (TENS) on pain and impression of change was assessed during a 2.5-hour intervention on the first postoperative days following hip surgery in a randomized, single-blinded, placebo-controlled trial involving 30 patients. Methods: Mixed-frequency TENS (2 Hz/80 Hz) was administered using specially designed pants integrating modular textile electrodes to facilitate stimulation both at rest and during activity. The treatment outcome was assessed by self-reported pain Numerical Rating Scale (NRS) and Patient Global Impression of Change (PGIC) scores at four time points. The ability to perform a 3-meter walk test and the use of analgesics were also evaluated. Group comparison and repeated-measure analysis were carried out using nonparametric statistics. Results: The active TENS group exhibited significantly higher PGIC scores after 30 minutes, which persisted throughout the intervention (all p ≤ 0.001). A reduction in NRS appeared after one hour of active TENS, persisting throughout the intervention (all p ≤ 0.05). The median group differences in pain ratings were greater than the minimum clinically important difference, and the analysis of pain trajectories confirmed clinical significance at the individual level. Moreover, patients in the active TENS group were more likely able to perform a 3-meter walk test by the end of the intervention (p = 0.04). Analysis of the opioid-sparing effect of TENS was inconclusive (p = 0.066). No postoperative surgical complications or TENS-related side effects were observed during the study. Conclusion: Mixed-frequency TENS integrated in pants could potentially be an interesting addition to the arsenal of treatments for multimodal analgesia following hip surgery. This trial is registered with NCT05678101.


Subject(s)
Pain Measurement , Pain, Postoperative , Transcutaneous Electric Nerve Stimulation , Humans , Transcutaneous Electric Nerve Stimulation/methods , Male , Female , Pain, Postoperative/therapy , Pain, Postoperative/etiology , Middle Aged , Aged , Single-Blind Method , Treatment Outcome , Adult , Pain Management/methods , Hip/surgery
2.
J Infect Dev Ctries ; 18(4): 587-594, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38728640

ABSTRACT

INTRODUCTION: Postoperative urinary retention (POUR) is a common complication after hip surgery. The enhanced recovery urinary protocol (ERUP) is a tool that employs several perioperative strategies to facilitate optimal conditions for surgery and recovery. The aim of this study was to evaluate the effect of ERUP on POUR in patients undergoing hip surgery. METHODOLOGY: A controlled pre- and post-quasi-experimental study was conducted. Data was collected between May 2018 and January 2019 at the orthopedic department of one of the largest teaching hospitals affiliated with Menoufia University in Egypt. A convenience sample of 100 Egyptian patients (of both genders) undergoing elective hip surgery was equally allocated into two groups. The control group (n = 50) was given traditional routine perioperative nursing care, while the intervention group (n = 50) was subjected to ERUP. Data was collected from socio-demographic, medical, and surgical data sheets, preoperative medication assessment sheets, postoperative data sheets, and fluid balance charts. RESULTS: ERUP application significantly reduced the length of hospital stay and the incidence of POUR in the intervention group. CONCLUSIONS: Implementation of the ERUP is recommended for patients undergoing hip surgery, as it has a significantly positive effect on reducing the incidence of POUR.


Subject(s)
Postoperative Complications , Humans , Male , Female , Middle Aged , Postoperative Complications/prevention & control , Egypt , Adult , Length of Stay , Urinary Retention/etiology , Aged , Hip/surgery , Incidence
3.
Medicina (Kaunas) ; 60(5)2024 May 11.
Article in English | MEDLINE | ID: mdl-38792981

ABSTRACT

Background and Objectives: The aim of this study was to compare the effectiveness of pericapsular nerve group (PENG) and lumbar erector spinae plane (L-ESP) blocks, both administered with a high volume (40 mL) of local anesthetic (LA), for multimodal postoperative analgesia in patients undergoing hip surgery. Materials and Methods: This was a prospective, double-blind, randomized study that included 75 adult patients who were divided into three equal groups: control, PENG, and L-ESP. The study compared pain intensity, morphine consumption, time to first morphine request, and postoperative satisfaction between the control group, which received standard multimodal analgesia, and the block groups, which received PENG or L-ESP block in addition to multimodal analgesia. The numerical rating scale (NRS) was used to measure pain intensity. Results: The results showed that the block groups had lower pain intensity scores and morphine consumption, a longer time to the first morphine request, and higher postoperative satisfaction compared to the control group. The median maximum NRS score during the first 12 h was four in the control group, two in the PENG group, and three in the L-ESP group. The control group (21.52 ± 9.63 mg) consumed more morphine than the two block groups (PENG, 11.20 ± 7.55 mg; L-ESP, 12.88 ± 8.87 mg) and requested morphine 6.8 h earlier and 5 h earlier than the PENG and L-ESP groups, respectively. The control group (median 3) had the lowest Likert satisfaction scores, while the PENG group (median 4) had the lowest NRS scores (L-ESP, median 4). Conclusions: The application of PENG or L-ESP blocks with high-volume LA in patients undergoing hip surgery reduces the need for postoperative analgesia and improves the quality of multimodal analgesia.


Subject(s)
Nerve Block , Pain, Postoperative , Humans , Nerve Block/methods , Male , Female , Double-Blind Method , Prospective Studies , Middle Aged , Pain, Postoperative/prevention & control , Pain, Postoperative/drug therapy , Pain Measurement/methods , Adult , Aged , Elective Surgical Procedures , Hip/surgery , Pain Management/methods , Pain Management/standards , Anesthetics, Local/administration & dosage , Anesthetics, Local/therapeutic use , Morphine/administration & dosage , Morphine/therapeutic use , Analgesia/methods
4.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 108-120, Mar-Abr. 2024. ilus, tab
Article in Spanish | IBECS | ID: ibc-231887

ABSTRACT

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Subject(s)
Humans , Male , Female , Aged , Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Hip Fractures , Hip/surgery , Spain , Epidemiology, Descriptive , Prospective Studies , Orthopedic Procedures , Traumatology
5.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T108-T120, Mar-Abr. 2024. ilus, tab
Article in English | IBECS | ID: ibc-231888

ABSTRACT

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Subject(s)
Humans , Male , Female , Aged , Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Hip Fractures , Hip/surgery , Spain , Epidemiology, Descriptive , Prospective Studies , Orthopedic Procedures , Traumatology
6.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): 121-127, Mar-Abr. 2024. tab
Article in Spanish | IBECS | ID: ibc-231889

ABSTRACT

Antecedentes y objetivos: La escala de Harris modificada (EHM) es una de las herramientas más utilizadas para valorar pacientes con patología de cadera. A pesar de contar con una adaptación transcultural al español realizada por Lara et al., no cuenta con estudios que sustenten su validez. Se pretende obtener una validación de la versión adaptada de la EHM (ES-EHM), comparándola con la escala WOMAC. Materiales y métodos: La ES-EHM se aplicó a 100 pacientes operados de prótesis total de cadera: (1) previamente a la cirugía (ES-EHM prequirúrgica), (2) 2 años tras la cirugía (ES-EHM posquirúrgica) y (3) 6 meses después de la aplicación de la ES-EHM posquirúrgica (ES-EHM final). Se aplicó también, en una ocasión, el cuestionario WOMAC. Se compararon las medias de la ES-EHM prequirúrgica, posquirúrgica y final, así como la totalidad y los parámetros de dolor y función de la ES-EHM con la escala WOMAC. Se obtuvieron parámetros de fiabilidad, validez y sensibilidad al cambio. Resultados: Al comparar la ES-EHM prequirúrgica y la posquirúrgica, se observó una mejoría clínicamente relevante (46,54 puntos). Al comparar la ES-EHM posquirúrgica y la final, no se detectaron diferencias. Se obtuvo una correlación fuerte entre: (1) la ES-EHM posquirúrgica y la ES-EHM final, (2) ES-EHM y WOMAC y (3) parámetros de dolor y función de la ES-EHM y la WOMAC. El índice de respuesta media estandarizada fue de 2,99, la fiabilidad test-retest representada por el coeficiente de correlación intraclase de 0,90 y el índice de consistencia interna alfa de Cronbach de 0,95. Conclusiones: La adaptación transcultural de la ES-EHM muestra ser fiable, válida y sensible al cambio. Por lo tanto, el personal médico de la población española podrá aplicar la ES-EHM con el respaldo científico y la certeza de estar midiendo los parámetros deseados.(AU)


Background and objectives: Modified Harris Hip Score (HHS) is one of the most used scales in the assessment of patients with hip pathology. Although a Spanish cross-cultural adaptation has been recently published, there are many studies supporting its validity yet. Therefore, the aim of this study is to validate the newly adapted Spanish version of the HHS (ES-EHM), comparing it with the WOMAC scale. Materials and methods: The ES-EHM scale was applied to 100 patients who underwent a total hip replacement, in three different situations: (1) prior to surgery (pre-surgical ES-EHM), (2) after surgery, with at least 2 years of follow up (after surgery ES-EHM), and (3) 6 months after the postsurgical registration (final ES-EHM). WOMAC questionnaire was also applied once. We analyzed data of scale main score, pain score, function-related score as well as the mean of pre-surgical, postsurgical and final postsurgical ES-EHM scale, in both the ES-EHM and the WOMAC scales. Parameters of reliability, validity and sensitivity to change were obtained. Results: Clinically relevant improvement was observed (46.55 points) when comparing pre-surgical and post-surgical ES-EHM scores. However, no differences between postsurgical and final ES-EHM were detected. Even so, strong correlation was obtained between the following: (1) postsurgical ES-EHM and final ES-EHM scores, (2) ES-EHM and WOMAC scores, and (3) pain and function-related parameters of ES-EHM and WOMAC scores. Standardized response mean (SRM) was 2.99, test–retest reliability expressed by the intraclass correlation coefficient was 0.90 and Cronbach index 0.95. ConclusionsThe Spanish cross-cultural adaptation of the EHM scale shows to be reliable, valid and sensitive to change. Thus, the Spanish medical staff will be able to apply the ES-EHM scale with good scientific support.(AU)


Subject(s)
Humans , Male , Female , Hip/pathology , Hip/surgery , Hip Fractures , Cultural Diffusion , Hip Prosthesis , Pain Management , Orthopedic Procedures
7.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(2): T121-T127, Mar-Abr. 2024. ilus, tab
Article in English | IBECS | ID: ibc-231890

ABSTRACT

Objetivos: Resultados clínicos, radiológicos y funcionales de la primera serie española de pacientes intervenidos de artroplastia total de cadera (ATC) asistida mediante brazo robótico Mako® (Stryker) del Hospital Clínico San Carlos (HCSC) de Madrid. Material y métodos: Estudio descriptivo prospectivo que analiza los primeros 25 pacientes intervenidos de ATC asistida por robot (ATCaR) en el HCSC, con un seguimiento mínimo de 4meses. Se evaluaron la demografía, los estudios de imagen (procesamiento Mako®, Rx y TAC), los parámetros clínicos, la funcionalidad (Harris modificada) y las complicaciones asociadas. Resultados: La edad media fue 67,2años (min 47, max 88), siendo el 56% varones. El 88% corresponden a coxartrosis primaria, el 4% postraumática, el 4% secundaria a NAV y el 4% secundaria a choque femoroacetabular. El tiempo medio de cirugía fue de 116,9minutos (min 92, max 150). La media de las cinco primeras intervenciones fue 122,6minutos, y la de las cinco últimas, de 108,2minutos. Como complicaciones intraoperatorias se cuantificaron 4 pérdidas de marcadores intraoperatorios. El tiempo de ingreso medio fue 4,4días (min 3, max 7), con una disminución de hemoglobina posquirúrgica media de 3,08±1,08g/dl, requiriendo transfusión en el 12% de los casos. Se registran tres complicaciones médicas durante el ingreso, destacando un síndrome confusional con caída y fractura periprotésica AG1 no desplazada. El análisis del posicionamiento de los implantes registrados con sistema Mako® fueron 40,55±1,53 grados de inclinación y 12,2±3,6 grados de anteversión acetabular. El estudio de imagen posquirúrgico realizado a los pacientes, en concordancia con Mako®, muestra valores de inclinación acetabular de 41,2±1,7 en Rx y versión acetabular de 16±4,6 en TAC. La discrepancia de longitud de cadera varía de valores preoperatorios de −3,91mm (DE: 3,9; min −12, max 3) a 1,29mm (DE: 1,96) tras la cirugía registrados con Mako...(AU)


Objectives: Clinical, radiological and functional results of the first Spanish series of patients undergoing total hip arthroplasty assisted by Mako® (Stryker) robotic arm at the Hospital Clínico San Carlos (HCSC) in Madrid. Material and methods: Prospective and descriptive study analyzing the first 25 patients who underwent robotic-assisted THA at the HCSC, with a minimum follow-up of 4months. Demographics, imaging studies (Mako® processing, Rx and CT), clinical parameters, functionality (modified Harris) and associated complications were evaluated. Results: Average age was 67.2years (min 47, max 88), being 56% male population sample. 88% involves primary coxarthrosis, 4% post-traumatic coxarthrosis, 4% secondary avascular necrosis and 4% secondary femoroacetabular impingement. Average surgery time was 116.9min (min 92, max 150). The average time of the first five surgeries was 122.6min, and, regarding the last five interventions, it was 108.2min. Found medical intraoperative complications were four intraoperative markers loss. Average admission time was 4.4days (min 3, max 7), with an average postoperative hemoglobin decrease of 3.08±1.08g/dL, requiring a transfusion in 12% of the cases. Three medical complications have been registered in the meantime of the admission, with a relevant case of a confusional syndrome and a fall, which resulted in a non-displaced AG1 periprosthetic fracture. The analysis of the positioning of registered implants with Mako® system shows 40.55±1.53 acetabular inclination degrees and 12.2±3.6 acetabular anteversion degrees. The postoperative image study carried out on patients, are consistent with Mako® s results, as it shows an acetabular inclination of 41.2±1.7 in Rx, as well as acetabular anteversion of 16±4.6 in CT. Hip length variance ranges depending on preoperative values of 3.91mm (SD: 3.9; min −12, max 3) to 1.29mm (SD: 1.96) after surgery registered with...(AU)


Subject(s)
Humans , Male , Female , Arthroplasty, Replacement, Hip , Robotic Surgical Procedures , Hip Fractures , Hip/surgery , Spain , Epidemiology, Descriptive , Prospective Studies , Orthopedic Procedures , Traumatology
8.
Gerontology ; 70(5): 491-498, 2024.
Article in English | MEDLINE | ID: mdl-38479368

ABSTRACT

INTRODUCTION: We analyzed the effect of dexmedetomidine (DEX) as a local anesthetic adjuvant on postoperative delirium (POD) in elderly patients undergoing elective hip surgery. METHODS: In this study, 120 patients undergoing hip surgery were enrolled and randomly assigned to two groups: fascia iliaca compartment block with DEX + ropivacaine (the Y group, n = 60) and fascia iliaca compartment block with ropivacaine (the R group, n = 60). The primary outcomes: presence of delirium during the postanesthesia care unit (PACU) period and on the first day (D1), the second day (D2), and the third day (D3) after surgery. The secondary outcomes: preoperative and postoperative C-reactive protein (CRP) and erythrocyte sedimentation rate (ESR), occurrence of insomnia on the preoperative day, day of operation, D1 and D2; HR values of patients in both groups before iliac fascia block (T1), 30 min after iliac fascia block (T2), at surgical incision (T3), 20 min after incision (T4), when they were transferred out of the operating room (T5) and after leaving the recovery room (T6) at each time point; VAS for T1, PACU, D1, D2; the number of patients requiring remedial analgesics within 24 h after blockade and related complications between the two groups. RESULTS: A total of 97 patients were included in the final analysis, with 11 and 12 patients withdrawing from the R and Y groups, respectively. The overall incidence of POD and its incidence in the PACU and ward were all lesser in the Y group than in the R group (p < 0.05). Additionally, fewer cases required remedial analgesia during the PACU period, and more vasoactive drugs were used for maintaining circulatory system stability in the Y group as compared to the R group (p < 0.05). At the same time, the incidence of intraoperative and postoperative bradycardia in the Y group was higher than that in the R group, accompanied by lower postoperative CRP and ESR (all p < 0.05). CONCLUSION: Ultrasound-guided high fascia iliaca compartment block with a combination of ropivacaine and DEX can reduce the incidence of POD, the use of intraoperative opioids and postoperative remedial analgesics, and postoperative inflammation in elderly patients who have undergone hip surgery, indicating that this method could be beneficial in the prevention and treatment of POD.


Subject(s)
Anesthetics, Local , Dexmedetomidine , Elective Surgical Procedures , Nerve Block , Ropivacaine , Humans , Dexmedetomidine/administration & dosage , Male , Aged , Female , Anesthetics, Local/administration & dosage , Nerve Block/methods , Ropivacaine/administration & dosage , Elective Surgical Procedures/adverse effects , Elective Surgical Procedures/methods , Fascia , Aged, 80 and over , Emergence Delirium/prevention & control , Emergence Delirium/epidemiology , Postoperative Complications/prevention & control , Postoperative Complications/epidemiology , Hip/surgery , Arthroplasty, Replacement, Hip/adverse effects , Arthroplasty, Replacement, Hip/methods
9.
Rev. esp. anestesiol. reanim ; 71(3): 160-170, Mar. 2024. tab, ilus
Article in Spanish | IBECS | ID: ibc-230929

ABSTRACT

Introducción: La artroplastia total de cadera es una de las intervenciones quirúrgicas más frecuentes en el contexto hospitalario. Sin embargo, sigue desconociéndose el método ideal para manejar el dolor postoperatorio. Las técnicas de analgesia multimodal basadas en la anestesia regional se encuentran entre las soluciones más prometedoras. Objetivos: El objetivo de este estudio fue evaluar el dolor postoperatorio tras la artroplastia total de cadera, de acuerdo con si se realizaron, o no, bloqueos del nervio periférico (bloqueo femoral, bloqueo de la fascia iliaca y bloqueo del grupo de nervios pericapsulares). Se midió el consumo de morfina intravenosa durante la estancia del paciente en la unidad de cuidados posanestésicos, así como el número de rescates con opioides transcurridas 24 y 48 h de la intervención. Como objetivos secundarios, se establecieron la prevalencia de la lesión nerviosa, la prolongación del bloqueo cuadricipital y el consumo de morfina, de acuerdo con otras variables de interés. Materiales y métodos: En este estudio retrospectivo observacional, se recopilaron datos de la historia clínica digital de 656 pacientes de cirugía traumatológica de abril de 2018 a agosto de 2020, con los criterios de inclusión siguientes: mayores de 18 años, ASA I-III, artroplastia total de cadera primaria con anestesia general o anestesia subaracnoidea (solo con bupivacaína hiperbárica) y uso de levobupivacaína para el bloqueo del nervio periférico. Resultados: Se seleccionó un total de 362 pacientes. La indicación quirúrgica principal fue coxartrosis (61,3%), seguida de fractura de cadera (22,6%). Se realizaron bloqueos del nervio periférico en 169 pacientes (66,3% femoral, 27,7% PENG, y 6% de fascia ilíaca). El consumo medio postoperatorio de opioides en la UCPA fue inferior en los pacientes que recibieron bloqueo PENG (2,2 mg) o femoral (3,27 mg), en comparación con los que no recibieron ninguno de los dos (6,69 mg)...(AU)


Introduction: Total hip arthroplasty is one of the most frequent surgical interventions in the hospital setting. Nonetheless, the ideal method to manage post-operative pain is still unknown. Multimodal analgesia techniques based on regional anaesthesia are amongst the most promising solutions. Objectives: The aim of this study was to evaluate postoperative pain after total hip arthroplasty according to whether peripheral nerve block was performed (femoral block, fascia iliaca block and pericapsular nerve group block). Intravenous morphine consumption during the patient's stay in the post-anaesthesia care unit was measured, as well as the number of opioid rescues at 24 and 48h post intervention. As secondary objectives, the prevalence of nerve injury, prolonged quadricipital block, and morphine consumption were established according to other variables of interest. Materials and methods: In this observational retrospective study, data was collected from the electronic medical record of 656 traumatological surgery patients from April 2018 to August 2020, with the following inclusion criteria: over 18 years old, ASA I-III, primary total hip arthroplasty under general anaesthesia or subarachnoid anaesthesia (only with hyperbaric bupivacaine) and use of levobupivacaine for peripheral nerve block. Results: A total of 362 patients were selected. The main surgical indication was coxarthrosis (61.3%), followed by hip fracture (22.6%). Peripheral nerve blocks were performed on 169 patients (66.3% femoral, 27.7% PENG, and 6.0% fascia iliaca). Mean postoperative opioid consumption in PACU was lower in patients in who received a PENG (2.2 mg) or a femoral (3.27 mg) block, compared to those who received neither (6.69 mg). There were no differences in opioid rescues at 24 and 48h after the procedure...(AU)


Subject(s)
Humans , Male , Female , Hip Injuries/surgery , Hip Fractures/surgery , Arthroplasty, Replacement, Hip , Anesthesia, Conduction , Retrospective Studies , Anesthesiology , Hip/surgery , Analgesia
10.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): 26-34, Ene-Feb, 2024. tab, graf
Article in Spanish | IBECS | ID: ibc-229667

ABSTRACT

Introducción y objetivos: Los vástagos primarios con cuellos modulares fueron introducidos con la ventaja teórica de restaurar la anatomía de la cadera de forma más precisa. Sin embargo, la presencia de un segundo encaje se ha asociado a una mayor corrosión y liberación de detritos metálicos. El objetivo de nuestro estudio es cuantificar los valores séricos de cromo y de cobalto, y analizar su evolución temporal durante cinco años. Material y métodos: Se presenta una serie prospectiva de 61 pacientes intervenidos de artroplastia total de cadera primaria mediante la implantación del vástago HMAX-M® (Limacorporate, San Daniele, Italia) en los que se realizó una determinación sérica de cromo y cobalto a los seis meses, a los dos años y a los cinco años. Resultados: Nuestra serie presenta una elevación progresiva de los niveles de cromo, con una diferencia significativa entre los valores de cromo a los seis meses (0,35±0,18) y los cinco años (0,52±0,36), p=0,01. Respecto al cobalto, se observa una elevación estadísticamente significativa entre los seis meses y los dos años y una posterior estabilización hasta los cinco años, siendo la media de cobalto a los seis meses (1,17±0,8) significativamente menor que a los dos años (2,63±1,76) y a los cinco años (2,84±2,1), p=0,001. Conclusión: Se ha observado una elevación de los niveles séricos de cobalto en aquellos pacientes a los que se les implantó un vástago con cuello modular. Los resultados obtenidos en este estudio han limitado el uso de vástagos con cuello modular en nuestra práctica habitual.(AU)


Introduction and objectives: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. Material and methods: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. Results: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. Conclusion: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.(AU)


Subject(s)
Humans , Male , Female , Chromium/administration & dosage , Cobalt/administration & dosage , Arthroplasty, Replacement, Hip , Hip/surgery , Ions , Iron/blood , Prospective Studies , Traumatology , Orthopedics , Orthopedic Procedures , Hip Injuries , Italy
11.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): T26-T34, Ene-Feb, 2024. tab, graf
Article in English | IBECS | ID: ibc-229668

ABSTRACT

Introducción y objetivos: Los vástagos primarios con cuellos modulares fueron introducidos con la ventaja teórica de restaurar la anatomía de la cadera de forma más precisa. Sin embargo, la presencia de un segundo encaje se ha asociado a una mayor corrosión y liberación de detritos metálicos. El objetivo de nuestro estudio es cuantificar los valores séricos de cromo y de cobalto, y analizar su evolución temporal durante cinco años. Material y métodos: Se presenta una serie prospectiva de 61 pacientes intervenidos de artroplastia total de cadera primaria mediante la implantación del vástago HMAX-M® (Limacorporate, San Daniele, Italia) en los que se realizó una determinación sérica de cromo y cobalto a los seis meses, a los dos años y a los cinco años. Resultados: Nuestra serie presenta una elevación progresiva de los niveles de cromo, con una diferencia significativa entre los valores de cromo a los seis meses (0,35±0,18) y los cinco años (0,52±0,36), p=0,01. Respecto al cobalto, se observa una elevación estadísticamente significativa entre los seis meses y los dos años y una posterior estabilización hasta los cinco años, siendo la media de cobalto a los seis meses (1,17±0,8) significativamente menor que a los dos años (2,63±1,76) y a los cinco años (2,84±2,1), p=0,001. Conclusión: Se ha observado una elevación de los niveles séricos de cobalto en aquellos pacientes a los que se les implantó un vástago con cuello modular. Los resultados obtenidos en este estudio han limitado el uso de vástagos con cuello modular en nuestra práctica habitual.(AU)


Introduction and objectives: Modular neck primary stems were introduced with the theoretical advantage of restoring the hip anatomy more precisely. However, the presence of a second junction has been associated with increased corrosion and release of metal debris. The objective of our study is to quantify of chromium and cobalt serum values, and to analyze their temporal evolution during five years. Material and methods: We present a prospective series of 61 patients who underwent primary total hip arthroplasty by implantation of the HMAX-M® stem (Limacorporate, San Daniele, Italy). Serum chromium and cobalt determinations were performed at six months, two years and five years. Results: Our series shows a progressive elevation in chromium levels with a significant difference between chromium values at six months (0.35±0.18) and five years (0.52±0.36), P=.01. Regarding cobalt, a statistically significant elevation is observed between six months and two years and a subsequent stabilization of values between two and five years, with a cobalt mean at six months (1.17±0.8) significantly lower than at two (2.63±1.76) and five years (2.84±2.1), P=.001. Conclusion: Elevated serum cobalt levels have been observed in patients who underwent modular neck stem implantation. The results obtained in this study have limited the use of stems with a modular neck in our clinical practice.(AU)


Subject(s)
Humans , Male , Female , Chromium/administration & dosage , Cobalt/administration & dosage , Arthroplasty, Replacement, Hip , Hip/surgery , Ions , Iron/blood , Prospective Studies , Traumatology , Orthopedics , Orthopedic Procedures , Hip Injuries , Italy
12.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): 50-56, Ene-Feb, 2024. ilus, tab
Article in Spanish | IBECS | ID: ibc-229673

ABSTRACT

Antecedentes y objetivo: La síntesis con tornillos canulados es uno de los métodos aceptados en las fracturas de cuello femoral, aunque su óptima disposición es un tema en continuo debate. El objetivo principal fue comparar los resultados del paciente con fractura de cuello de fémur fijada con tres tornillos en configuración triangular y en triángulo invertido en el plano frontal. Materiales y métodos: Estudio retrospectivo y comparativo de 53 pacientes con fractura de cuello femoral intervenidos entre 2015 y 2022 mediante fijación con tres tornillos canulados: 22 conformados en triángulo (grupo triángulo) y 31 en triángulo invertido (grupo triángulo invertido). Se evaluó la funcionalidad mediante la escala modificada de Merlé d’Aubigné, la capacidad para la deambulación con la escala de Koval, así como las complicaciones postoperatorias. Resultados: En la escala de Merlé d’Aubigné la puntuación media fue de 16,7 en el grupo triángulo y de 16,1 en el grupo triángulo invertido (p=0,259). En la escala de Koval se observó una disminución significativa, pasando de 1,6 de media preoperatoria a 2,2 tras la cirugía (p=0,000), no hallando diferencias entre grupos. Hubo seis complicaciones postoperatorias en el grupo triángulo y tres en el grupo triángulo invertido (p=0,140). Conclusión: La configuración de los tornillos en el cuello femoral, tanto en forma de triángulo como en triángulo invertido, no influyó en los resultados funcionales ni mecánicos de los pacientes con fractura de cuello de fémur fijada mediante tres tornillos canulados.(AU)


Background and objective: Synthesis with cannulated screws is one of the accepted methods in femoral neck fractures, although its optimal configuration is a subject in continuous debate. The main objective was to compare the results of the patient with a femoral neck fracture fixed with three screws in triangle and inverted triangle configuration in the frontal plane. Materials and methods: Retrospective and comparative study of 53 patients with femoral neck fracture, operated between 2015 and 2022 with fixation with three cannulated screws, 22 with a triangle configuration (triangle group) and 31 in an inverted triangle (inverted triangle group). Functionality was evaluated using the modified Merlé d’Aubigné scale, walking ability using the Koval scale, as well as postoperative complications. Results: On the Merlé d’Aubigné scale, the mean score was 16.7 in the triangle group and 16.1 in the inverted triangle group (P=.259). On the Koval scale, a significant decrease was observed, going from 1.6 preoperative mean to 2.2 after surgery (P=.000), finding no differences between groups. There were six postoperative complications in the triangle group and three in the inverted triangle group (P=.140). Conclusion: The configuration of the screws in the femoral neck, both in the form of a triangle and an inverted triangle, did not influence the functional or mechanical outcomes of the patients with a femoral neck fracture fixed with three cannulated screws.(AU)


Subject(s)
Humans , Male , Female , Femur Neck/surgery , Fracture Fixation, Internal , Bone Screws , Necrosis , Pseudarthrosis , Hip Fractures/surgery , Traumatology , Orthopedics , Orthopedic Procedures , Retrospective Studies , Fractures, Bone/surgery , Hip Injuries , Hip/surgery
13.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 68(1): T50-T56, Ene-Feb, 2024. ilus, tab
Article in English | IBECS | ID: ibc-229674

ABSTRACT

Antecedentes y objetivo: La síntesis con tornillos canulados es uno de los métodos aceptados en las fracturas de cuello femoral, aunque su óptima disposición es un tema en continuo debate. El objetivo principal fue comparar los resultados del paciente con fractura de cuello de fémur fijada con tres tornillos en configuración triangular y en triángulo invertido en el plano frontal. Materiales y métodos: Estudio retrospectivo y comparativo de 53 pacientes con fractura de cuello femoral intervenidos entre 2015 y 2022 mediante fijación con tres tornillos canulados: 22 conformados en triángulo (grupo triángulo) y 31 en triángulo invertido (grupo triángulo invertido). Se evaluó la funcionalidad mediante la escala modificada de Merlé d’Aubigné, la capacidad para la deambulación con la escala de Koval, así como las complicaciones postoperatorias. Resultados: En la escala de Merlé d’Aubigné la puntuación media fue de 16,7 en el grupo triángulo y de 16,1 en el grupo triángulo invertido (p=0,259). En la escala de Koval se observó una disminución significativa, pasando de 1,6 de media preoperatoria a 2,2 tras la cirugía (p=0,000), no hallando diferencias entre grupos. Hubo seis complicaciones postoperatorias en el grupo triángulo y tres en el grupo triángulo invertido (p=0,140). Conclusión: La configuración de los tornillos en el cuello femoral, tanto en forma de triángulo como en triángulo invertido, no influyó en los resultados funcionales ni mecánicos de los pacientes con fractura de cuello de fémur fijada mediante tres tornillos canulados.(AU)


Background and objective: Synthesis with cannulated screws is one of the accepted methods in femoral neck fractures, although its optimal configuration is a subject in continuous debate. The main objective was to compare the results of the patient with a femoral neck fracture fixed with three screws in triangle and inverted triangle configuration in the frontal plane. Materials and methods: Retrospective and comparative study of 53 patients with femoral neck fracture, operated between 2015 and 2022 with fixation with three cannulated screws, 22 with a triangle configuration (triangle group) and 31 in an inverted triangle (inverted triangle group). Functionality was evaluated using the modified Merlé d’Aubigné scale, walking ability using the Koval scale, as well as postoperative complications. Results: On the Merlé d’Aubigné scale, the mean score was 16.7 in the triangle group and 16.1 in the inverted triangle group (P=.259). On the Koval scale, a significant decrease was observed, going from 1.6 preoperative mean to 2.2 after surgery (P=.000), finding no differences between groups. There were six postoperative complications in the triangle group and three in the inverted triangle group (P=.140). Conclusion: The configuration of the screws in the femoral neck, both in the form of a triangle and an inverted triangle, did not influence the functional or mechanical outcomes of the patients with a femoral neck fracture fixed with three cannulated screws.(AU)


Subject(s)
Humans , Male , Female , Femur Neck/surgery , Fracture Fixation, Internal , Bone Screws , Necrosis , Pseudarthrosis , Hip Fractures/surgery , Traumatology , Orthopedics , Orthopedic Procedures , Retrospective Studies , Fractures, Bone/surgery , Hip Injuries , Hip/surgery
14.
Spine Deform ; 12(3): 747-754, 2024 May.
Article in English | MEDLINE | ID: mdl-38227087

ABSTRACT

PURPOSE: Children and young adults with neuromuscular disorders have a high incidence of both spine and hip deformities. The aim of this study was to evaluate the outcome of either primary scoliosis or hip surgery in children and young adults with neuromuscular disorders. METHODS: A retrospective study was conducted on all children and young adults with neuromuscular-related synchronous hip subluxation/dislocation and scoliosis undergoing hip or scoliosis surgery in our institution between 2012 and 2021 with a minimum follow-up of 24 months. Demographic and operative data were collected; radiological parameters were measured preoperatively and postoperatively at final follow-up. RESULTS: Forty neuromuscular patients with synchronous hip displacement and scoliosis were included. Twenty patients with an average age of10.2 years had hip correction surgery performed primarily, with a mean follow-up of 54.9 (24-96) months. The other 20 patients with an average age of 12.4 years had scoliosis correction first, with a mean follow-up of 40 (24-60) months. In the "Hip first" group, pelvic obliquity, hip MP and Cobb angle were 16.8°, 71%, and 49°, respectively. At final follow-up, the mean pelvic obliquity and Cobb angles significantly progressed to 27.2° (p = 0.003) and 82.2° (p = 0.001), respectively. Eighteen patients (90%) required scoliosis correction after the hip surgery. In the "Scoliosis first" group, the mean pelvic obliquity, hip MP and Cobb angle were 21.2°, 49% and 65.5°, respectively. At final follow-up, both pelvic obliquity and Cobb angle significantly improved to 8.44° (p = 0.002) and 23.4° (p = 0.001), respectively. In 11/20 (55%) patients, the hip MP had significantly increased following the spinal surgery to 62% (p = 0.001), but only 5/20 (25%) patients underwent hip surgery after scoliosis correction. CONCLUSION: In neuromuscular patients presenting with synchronous hip displacement and scoliosis deformity, corrective scoliosis surgery is associated with a significant correction of pelvic obliquity and lower rates of secondary hip surgery. On the other hand, primary hip surgery does not reduce the risk of pelvic obliquity and scoliosis deformity progression.


Subject(s)
Neuromuscular Diseases , Scoliosis , Humans , Scoliosis/surgery , Scoliosis/diagnostic imaging , Retrospective Studies , Female , Child , Male , Neuromuscular Diseases/complications , Neuromuscular Diseases/surgery , Adolescent , Treatment Outcome , Young Adult , Hip Dislocation/surgery , Hip Dislocation/etiology , Follow-Up Studies , Hip/diagnostic imaging , Hip/surgery
15.
Arthroscopy ; 40(3): 799-801, 2024 03.
Article in English | MEDLINE | ID: mdl-38219091

ABSTRACT

Iliopsoas impingement pathology is one of the causes of persistent pain after total hip arthroplasty. It is reported as occurring in approximately 4% of cases; this may be significantly greater (in cases of postarthroplasty pain of unknown etiology). Inflammation is a result of impingement of the tendon against the acetabular component. This may occur with anteroinferior prominence when the cup is properly positioned in anteversion or when the cup is oversized. Other causes of impingement include a cup-reinforcement ring or acetabular cage, a collared femoral component, screws penetrating through the ilium, cement extrusion, anterior wall hypoplasia, or increased femoral offset. When conservative treatment does not achieve the best outcome, the 2 main therapeutic options are psoas tenotomy or revision of the cup component. Tenotomy can be performed either arthroscopically or by an open approach and may be considered the best option for many patients, even in cases with anterior component prominence, as it is less invasive, presents fewer complications, and has faster recovery. The debate is open. The level of tenotomy remains controversial, with risks and benefits of both a lesser trochanter and transcapsular approach.


Subject(s)
Arthroplasty, Replacement, Hip , Tendinopathy , Humans , Arthroplasty, Replacement, Hip/adverse effects , Tenotomy/adverse effects , Hip/surgery , Pain/etiology , Tendinopathy/complications , Psoas Muscles/surgery
16.
Rehabilitación (Madr., Ed. impr.) ; 57(4): [100811], Oct-Dic, 2023. graf, tab
Article in Spanish | IBECS | ID: ibc-228351

ABSTRACT

Introducción: En parálisis cerebral, la migración de la cabeza femoral se define como la pérdida de cobertura de esta por parte del acetábulo y se mide mediante el índice de Reimer. El tratamiento quirúrgico puede ser preventivo, reconstructivo o de salvamento, siendo los índices de fracaso de la cirugía elevados y relacionados con la severidad de la parálisis cerebral. El objetivo de nuestro trabajo es obtener la incidencia de la migración de caderas en nuestra serie de pacientes adultos con parálisis cerebral, determinar el resultado de las que han sido intervenidas quirúrgicamente y establecer la recurrencia que presentan las diversas técnicas quirúrgicas. Material y métodos: Se ha diseñado un estudio retrospectivo observacional para determinar el estado de las caderas de pacientes adultos con parálisis cerebral, que se han visitado en la Unidad entre los años 2008 y 2021. Resultados: La incidencia global de desplazamiento de la cadera fue de un 75%, aquellos pacientes con afectaciones más severas (GMFCS IV y V) tienen más predisposición a la luxación y además son más severas. Las cirugías sobre partes blandas constituyeron un 49,5% de las intervenciones realizadas con una tasa de fracaso de hasta el 82%. La cirugía reconstructiva se realizó en un 45,5% de las ocasiones, con un porcentaje de fracaso mayor al 86%. Conclusión: Actualmente, la implementación de programas de vigilancia de cadera pretende mejorar el seguimiento y las intervenciones aplicadas en el desplazamiento de la cadera, con el objetivo de mantener una cobertura acetabular óptima y, en todo caso, reducir la tasa de fracaso de las posibles cirugías.(AU)


Introduction: In cerebral palsy, femoral head migration is defined as the loss of coverage of the femoral head by the acetabulum and is measured using the Reimer index. Surgical treatment can be preventive, reconstructive, or salvage, and failure rates of surgery are high and related to the severity of cerebral palsy. The aim of our work is to assess the incidence of hip migration in our series of adult patients with cerebral palsy, to determine the outcome of those who have undergone surgery, and to establish recurrence rates after the various surgical techniques. Material and methods: We designed a retrospective observational study to determine the hip status of adult patients with cerebral palsy visiting the Unit between 2008 and 2021. Results: The overall incidence of hip displacement was 75%, patients with more extensive disability (GMFCS IV and V) were more predisposed to dislocation, also more severe. Soft tissue surgery made up 49.5% of the operations performed with a failure rate of up to 82%. Reconstructive surgery was performed in 45.5% of cases with a failure rate of more than 86%. Conclusion: The current hip surveillance programmes have been implemented to improve follow-up and interventions in hip displacement, with the objective of maintaining optimal acetabular coverage and reducing the failure rate of potential surgeries.(AU)


Subject(s)
Humans , Male , Female , Adult , Cerebral Palsy/complications , Hip Joint/physiopathology , Hip Dislocation , /surgery , Retrospective Studies , Rehabilitation , Hip/surgery , Spain
17.
Rev. osteoporos. metab. miner. (Internet) ; 15(3): 125-128, Juli-Sep. 2023. ilus
Article in English, Spanish | IBECS | ID: ibc-226997

ABSTRACT

La osificación heterotópica es una condición limitante, que afecta predominantemente a la cadera. Dada su relación con patología postraumática/posquirúrgica, la gammagrafía ósea SPECT/TC resulta de especial utilidad en el diagnóstico diferencial con movilización protésica, aun cuando no hay alteraciones radiológicas. Además, resulta ser una herramienta eficaz para planificación quirúrgica atendiendo al grado de maduración ósea y la posibilidad de fabricar biomodelos mediante impresión 3D.(AU)


Heterotopic ossification is a limiting condition that predominantly affects the hip. Because of its association with post-trau-matic/postoperative pathology, bone SPECT/CT scintigraphy has proven to be especially useful regarding differential diag-nosis involving prosthetic mobilization, even in the absence of radiological abnormalities. Additionally, it is an effective toolfor surgical planning, considering the degree of bone maturation and the possibility of creating biomodels using 3Dprinting.(AU)


Subject(s)
Humans , Male , Middle Aged , Ossification, Heterotopic , Arthroplasty, Replacement, Hip/methods , Radionuclide Imaging , Single Photon Emission Computed Tomography Computed Tomography , Hip Prosthesis , Inpatients , Physical Examination , Osteoporosis , Fractures, Bone/surgery , Osteoarthritis, Hip , Hip/surgery
18.
Rev. bras. ortop ; 58(4): 632-638, July-Aug. 2023. tab, graf
Article in English | LILACS | ID: biblio-1521803

ABSTRACT

Abstract Objective To evaluate the safety and reproducibility of the surgery for unstable slipped capital femoral epiphysis (SCFE) through the modified Dunn technique in a single center cohort from Brazil. Methods We retrospectively analyzed a cohort of patients submitted to this procedure by a single surgeon who was a hip preservation specialist. Demographic data and radiographic angles were evaluated for the relative risk (RR) of avascular necrosis (AVN) using a log-binomial regression model with simple and random effects. Results Among the 30 patients (30 hips) with a mean age of 11.79 years at the time of the operation, there were 17 boys and 18 left hips, which were operated on in a mean of 11.5 days after the slip. The mean follow-up was of 38 months. The preoperative Southwick angle averaged 60.69° against 4.52° postoperatively (p< 0.001). A larger preoperative slip angle was associated with the development of AVN (RR: 1.05; 95% confidence interval [95%CI]: 1.02-1.07; p< 0.01). The overall AVN rate was of 26.7%. Function was good or excellent in 86% of uncomplicated hips, and poor in 87.5% of the partients who developed AVN, as graded by the Harris Hip Score. There was no statistical relationship between epiphyseal bleeding and AVN development (p= 0.82). Conclusion The modified Dunn technique is associated with restoration of the femoral alignment and function after unstable SCFE, when uncomplicated. Moreover, it was shown to be reproducible in our population, with a rate of 26% of femoral head necrosis.


Resumo Objetivo Avaliar a segurança e a reprodutibilidade da cirurgia para escorregamento da epífise femoral proximal (EEPF) com instabilidade por meio da técnica de Dunn modificada em uma coorte unicêntrica no Brasil. Métodos Analisamos de forma retrospectiva uma coorte de pacientes submetidos a esse procedimento por um único cirurgião especialista em preservação do quadril. Avaliamos os dados demográficos e os ângulos radiográficos quanto ao risco relativo (RR) de necrose avascular (NAV) por meio do modelo de regressão log-binomial com efeitos simples e aleatórios. Resultados Entre os 30 pacientes (30 quadris) com idade média de 11,79 anos no momento da cirurgia, havia 17 meninos e 18 quadris esquerdos. O procedimento ocorreu em média 11,5 dias após o escorregamento. O tempo médio de acompanhamento foi de 38 meses. O ângulo de Southwick pré-operatório foi, em média, de 60,69° contra 4,52° após o procedimento (p< 0,001). O maior ângulo de escorregamento pré-operatório foi associado ao desenvolvimento de NAV (RR: 1,05; intervalo de confiança de 95% [IC95%]: 1,02-1,07; p< 0,01). A frequência geral de NAV foi de 26,7%. De acordo com a Escala de Quadril de Harris (Harris Hip Score), a função foi boa ou excelente em 86% dos quadris sem complicações, e ruim em 87,5% dos casos com NAV. Não houve relação estatística entre sangramento epifisário e desenvolvimento de NAV (p= 0,82). Conclusão A técnica de Dunn modificada restaura o alinhamento femoral e a função articular após o EEPF com instabilidade na ausência de complicações. Além disso, mostrou-se passível de reprodução em nossa população, com frequência de necrose da cabeça femoral de 26%.


Subject(s)
Humans , Male , Female , Child , Osteotomy , Femur Head Necrosis , Slipped Capital Femoral Epiphyses , Hip/surgery
19.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): 94-101, Mar-Abr. 2023. tab, ilus, graf
Article in Spanish | IBECS | ID: ibc-217102

ABSTRACT

Introducción: La cirugía de revisión acetabular supone un reto quirúrgico sobre todo cuando aparecen los defectos óseos complejos, pues dificultan la fijación primaria y osteointegración de los implantes, lo que condiciona la aparición de complicaciones. Los cotilos de titanio trabecular intentan solventar estos problemas. Objetivos: Valorar los resultados clínico-radiológicos, la supervivencia de los implantes y aparición de complicaciones a medio plazo en cirugía de revisión acetabular en una serie de 37 recambios acetabulares con defectos óseos tipo IIIA y IIIB de Paprosky en los que se utilizó un implante de revisión tipo Cup-Cage de titanio trabecular. Material y método: Realizamos un estudio observacional, descriptivo y retrospectivo de 37 casos con defectos acetabulares complejos (20 tipo IIIA y 17 tipo IIIB, cinco de ellos con discontinuidad pélvica) en los que se realizó recambio del componente acetabular por implantes de titanio trabecular entre los años 2011 y 2019. Analizamos resultados clínicos (dolor y funcionalidad) y parámetros radiológicos (restauración del centro de rotación de la cadera y la movilización de los implantes), así como la aparición de complicaciones. Resultados: El seguimiento medio fue de 61 meses. Obtuvimos una mejoría en la mediana de 8 puntos en la escala de funcionalidad de Merlé D’Aubigné-Postel y de 6 puntos en la escala EVA de dolor percibido por el paciente. Registramos dos casos de aflojamiento acetabular, un caso de inestabilidad y tres infecciones de herida quirúrgica sin afectar al implante. Conclusiones: La utilización de implantes tipo Cup-Cage de titanio trabecular podría constituir una opción válida en cirugía de revisión acetabular con defectos acetabulares complejos, presentando buenos resultados clínico-radiológicos y en cuanto a complicaciones y supervivencia de los implantes, debido a su buena fijación primaria y osteointegración.(AU)


Introduction: Acetabular revision surgery is a surgical challenge, especially when complex bone defects appear. This makes primary fixation and osseointegration of the implants difficult, which conditions the appearance of complications. Trabecular titanium implants attempt to solve these problems. Objectives: To evaluate our clinical-radiological results, the survival of the implants and the appearance of mid-term complications in acetabular revision surgery in a series of 37 acetabular replacements with Paprosky type IIIA and IIIB bone defects in which a trabecular titanium Cup-Cage revision implant was used. Material and method: We conducted an observational, descriptive and retrospective study of 37 cases with complex acetabular defects (20 type IIIA and 17 type IIIB, five of them with pelvic discontinuity) in which the acetabular component was replaced by trabecular titanium cups between 2011 and 2019. We analyzed clinical results (pain and functionality) and radiological parameters (restoration of the hip rotation centre and the mobilization of the implants), as well as the appearance of complications. Results: The mean follow-up was 61 months. We obtained a median improvement of 8 points on the Merlé D’Aubigné-Postel functionality scale and 6 points on the VAS scale of pain perceived by the patient. We recorded two cases of acetabular loosening, one case of dislocation and three surgical wound infections without affecting the implant. Conclusions: The use of trabecular titanium Cup-Cage implants could be a valid option in acetabular revision surgery with complex acetabular defects, presenting good clinical and radiological results and in terms of complications and survival of the implants, mainly due to their good primary fixation and subsequent osseointegration.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Prostheses and Implants , Titanium , Reoperation , Hip/surgery , Hip Prosthesis , Retrospective Studies , Epidemiology, Descriptive , Orthopedics
20.
Rev. esp. cir. ortop. traumatol. (Ed. impr.) ; 67(2): T94-T101, Mar-Abr. 2023. tab, ilus, graf
Article in English | IBECS | ID: ibc-217103

ABSTRACT

Introducción: La cirugía de revisión acetabular supone un reto quirúrgico sobre todo cuando aparecen los defectos óseos complejos, pues dificultan la fijación primaria y osteointegración de los implantes, lo que condiciona la aparición de complicaciones. Los cotilos de titanio trabecular intentan solventar estos problemas. Objetivos: Valorar los resultados clínico-radiológicos, la supervivencia de los implantes y aparición de complicaciones a medio plazo en cirugía de revisión acetabular en una serie de 37 recambios acetabulares con defectos óseos tipo IIIA y IIIB de Paprosky en los que se utilizó un implante de revisión tipo Cup-Cage de titanio trabecular. Material y método: Realizamos un estudio observacional, descriptivo y retrospectivo de 37 casos con defectos acetabulares complejos (20 tipo IIIA y 17 tipo IIIB, cinco de ellos con discontinuidad pélvica) en los que se realizó recambio del componente acetabular por implantes de titanio trabecular entre los años 2011 y 2019. Analizamos resultados clínicos (dolor y funcionalidad) y parámetros radiológicos (restauración del centro de rotación de la cadera y la movilización de los implantes), así como la aparición de complicaciones. Resultados: El seguimiento medio fue de 61 meses. Obtuvimos una mejoría en la mediana de 8 puntos en la escala de funcionalidad de Merlé D’Aubigné-Postel y de 6 puntos en la escala EVA de dolor percibido por el paciente. Registramos dos casos de aflojamiento acetabular, un caso de inestabilidad y tres infecciones de herida quirúrgica sin afectar al implante. Conclusiones: La utilización de implantes tipo Cup-Cage de titanio trabecular podría constituir una opción válida en cirugía de revisión acetabular con defectos acetabulares complejos, presentando buenos resultados clínico-radiológicos y en cuanto a complicaciones y supervivencia de los implantes, debido a su buena fijación primaria y osteointegración.(AU)


Introduction: Acetabular revision surgery is a surgical challenge, especially when complex bone defects appear. This makes primary fixation and osseointegration of the implants difficult, which conditions the appearance of complications. Trabecular titanium implants attempt to solve these problems. Objectives: To evaluate our clinical-radiological results, the survival of the implants and the appearance of mid-term complications in acetabular revision surgery in a series of 37 acetabular replacements with Paprosky type IIIA and IIIB bone defects in which a trabecular titanium Cup-Cage revision implant was used. Material and method: We conducted an observational, descriptive and retrospective study of 37 cases with complex acetabular defects (20 type IIIA and 17 type IIIB, five of them with pelvic discontinuity) in which the acetabular component was replaced by trabecular titanium cups between 2011 and 2019. We analyzed clinical results (pain and functionality) and radiological parameters (restoration of the hip rotation centre and the mobilization of the implants), as well as the appearance of complications. Results: The mean follow-up was 61 months. We obtained a median improvement of 8 points on the Merlé D’Aubigné-Postel functionality scale and 6 points on the VAS scale of pain perceived by the patient. We recorded two cases of acetabular loosening, one case of dislocation and three surgical wound infections without affecting the implant. Conclusions: The use of trabecular titanium Cup-Cage implants could be a valid option in acetabular revision surgery with complex acetabular defects, presenting good clinical and radiological results and in terms of complications and survival of the implants, mainly due to their good primary fixation and subsequent osseointegration.(AU)


Subject(s)
Humans , Male , Female , Adult , Middle Aged , Aged , Prostheses and Implants , Titanium , Reoperation , Hip/surgery , Hip Prosthesis , Retrospective Studies , Epidemiology, Descriptive , Orthopedics
SELECTION OF CITATIONS
SEARCH DETAIL