Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.589
Filter
1.
Jt Dis Relat Surg ; 35(2): 439-442, 2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38727126

ABSTRACT

Tension band wiring (TBW) is one of the most commonly used fixation techniques to fix olecranon osteotomies. Hardware prominence has been the most commonly reported complication of TBW. However, distal migration of Kirschner (K)-wire after TBW fixation for olecranon osteotomy has not been reported. In this case report, we presented distal migration of K-wire detected nine months after initial surgery in a 46-year-old male patient. The patient was operated on for an intraarticular distal humerus fracture using an olecranon osteotomy. The osteotomy was fixed with TBW fixation. The patient missed routine follow-ups and presented to the outpatient clinic with a complaint of skin irritation at the elbow nine months after the surgery. On radiological examination, distal migration of one K-wire was detected. The K-wire was surgically removed without any complication. Physicians should be aware of possible complications of TBW and remove fixation after fracture union to avoid unexpected complications.


Subject(s)
Bone Wires , Foreign-Body Migration , Olecranon Process , Osteotomy , Humans , Bone Wires/adverse effects , Male , Middle Aged , Olecranon Process/injuries , Olecranon Process/surgery , Olecranon Process/diagnostic imaging , Osteotomy/adverse effects , Osteotomy/methods , Osteotomy/instrumentation , Foreign-Body Migration/surgery , Foreign-Body Migration/diagnostic imaging , Foreign-Body Migration/etiology , Humeral Fractures/surgery , Humeral Fractures/diagnostic imaging , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fracture Fixation, Internal/instrumentation , Device Removal/methods , Elbow Joint/surgery , Elbow Joint/diagnostic imaging , Intra-Articular Fractures/surgery , Intra-Articular Fractures/diagnostic imaging
2.
Bull Hosp Jt Dis (2013) ; 82(2): 154-158, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38739664

ABSTRACT

We report the treatment of two patient with humeral fractures with one or more risk factors for nonunion. The first patient was elderly with a previously diagnosed central nervous sys-tem injury. The second elderly patient previously sustained a cerebral vascular accident affecting the fractured arm. The fracture was oblique in the proximal third of the humerus. We achieved bone healing non-operatively utilizing a spe-cialized plastic orthosis that included a deforming element made of dense foam. This device asymmetrically increases the soft tissue pressure around the fracture.


Subject(s)
Fracture Healing , Fractures, Ununited , Humeral Fractures , Orthotic Devices , Humans , Humeral Fractures/surgery , Humeral Fractures/physiopathology , Humeral Fractures/diagnostic imaging , Fractures, Ununited/surgery , Fractures, Ununited/physiopathology , Fractures, Ununited/etiology , Risk Factors , Male , Treatment Outcome , Aged , Female , Equipment Design , Aged, 80 and over , Radiography
3.
J Pediatr Orthop ; 44(5): e426-e432, 2024.
Article in English | MEDLINE | ID: mdl-38454784

ABSTRACT

OBJECTIVE: This work aimed to evaluate the results of using a 2-stage surgical treatment strategy without doing anterior transposition of the ulnar nerve (ATUN) for cases with long-standing nonunited fracture lateral humeral condyle (LHC) in children, accompanied by a critical review. METHODS: A consecutive 12 children with a long-standing ">2 years" nonunited LHC with evident radiologic gross anatomic distortion of the elbow were included in this study. A 2-stage surgical treatment strategy was applied, wherein the first stage, open functional reduction, osteosynthesis, and iliac bone graft were done. Then after 6 months, the second stage surgery was carried out in the form of supracondylar humeral corrective osteotomy if the cubitus valgus angle was ≥20 degrees. ATUN was not done for any of the cases even with those having ulnar nerve dysfunction. RESULTS: Union took place in 11 out of the 12 cases after a mean follow-up period of 11 weeks (range: 8 to 14 wk; SD: 1.6). All the 7 cases showed preoperative ulnar nerve dysfunction and reported clinical recovery at the end of their follow-up. CONCLUSIONS: Two-stage surgical treatment strategy without ATUN is a convenient, reproducible, and successful line of treatment for children presented with longstanding nonunited LHC with anatomically distorted elbow. LEVEL OF EVIDENCE: Level IV-case series.


Subject(s)
Elbow Joint , Fractures, Ununited , Humeral Fractures , Child , Humans , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Humeral Fractures/complications , Humerus/surgery , Ulnar Nerve , Fracture Fixation, Internal/methods , Fractures, Ununited/surgery , Elbow Joint/surgery , Treatment Outcome , Range of Motion, Articular/physiology , Retrospective Studies
4.
JBJS Case Connect ; 14(1)2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38517980

ABSTRACT

CASE: We report a single case of a closed intra-articular distal humerus fracture in a 28-year-old man with a preexisting fishtail deformity characterized by concavity of the central trochlea and corresponding deformity of the olecranon. The patient was treated with open reduction and internal fixation. CONCLUSION: The case highlights the diagnosis and challenges of treatment. Conventional fixation choices and imaging techniques may need to be altered when treating a fracture with this deformity.


Subject(s)
Elbow Joint , Humeral Fractures, Distal , Humeral Fractures , Olecranon Process , Male , Humans , Adult , Humeral Fractures/complications , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Fracture Fixation, Internal , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Olecranon Process/diagnostic imaging
6.
Int Orthop ; 48(5): 1295-1302, 2024 May.
Article in English | MEDLINE | ID: mdl-38502337

ABSTRACT

PURPOSE: Coronal shear fractures of the distal humerus involving the capitellum and trochlea are rare injuries. Internal fixation with headless compression screws provides a stable construct facilitating early mobilisation. Our study aimed to identify the key determinants of both radiological and functional outcomes of patients with distal humerus coronal shear fractures treated with internal fixation. METHODS: A retrospective analysis of 61 patients with distal humerus coronal shear fractures who were treated surgically was done. Demographics, fracture morphology, time to surgery, operative details such as surgical approach and implant used, quality of reduction, time to union, and associated complications from hospital records. Radiological outcomes were assessed using plain radiographs, and the functional outcomes were by Oxford Elbow Score (OES) and Mayo Elbow Performance Index (MEPI). RESULTS: Patients with anatomical reduction of the fracture had better functional outcomes and range of motion. The presence of posterior comminution of capitellum resulted in poorer outcomes (p = 0.03). Delayed presentation did not alter the outcome when the anatomical reduction was achieved. Myositis ossificans was noted in nine patients and non-union in five patients. Two patients developed avascular necrosis of the capitellum and arthritis of the elbow joint. CONCLUSION: Anatomical reduction and posterior comminution are the two key determinants of the functional outcome in these coronal shear fractures of the distal humerus. Early mobilisation following a stable fixation is crucial in achieving a good outcome.


Subject(s)
Elbow Joint , Fractures, Comminuted , Humeral Fractures , Humans , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Retrospective Studies , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Humerus , Radiography , Fracture Fixation, Internal/adverse effects , Fracture Fixation, Internal/methods , Fractures, Comminuted/surgery , Range of Motion, Articular , Treatment Outcome
7.
PLoS One ; 19(3): e0300014, 2024.
Article in English | MEDLINE | ID: mdl-38489337

ABSTRACT

Although lateral humeral condyle fracture is common, the incidence of missed diagnosis is very high. Delayed and missed diagnosis led to significant morbidities and loss of functions. We designed a pediatric elbow radiographic guidance aiming to improve the accuracy of diagnosis. This study was aimed to evaluate the efficacy of the radiographic guidance for the diagnosis of lateral condyle fracture. A cross-sectional study was conducted after defining the essential parameters as a guidance for assessing the pediatric elbow radiographs. We included medical students, emergency medicine, orthopedic, and radiology residents and fellows into this study. A questionnaire was used to evaluate the efficacy of the guidance. All participants underwent a pretest evaluation, followed by studying the guidance, and then finished a posttest evaluation. Baseline characteristics, diagnostic scores, and parameter evaluation scores were collected. The pretest and posttest scores were analyzed using paired t-test. Association between baseline characteristics and diagnostic scores were analyzed using multiple regression analysis. We included 177 participants. Average diagnostic score was significantly increased after using the guidance, from 12.2 ± 1.9 to 13.0 ± 1.7 (p < 0.0001). Medical students showed the most improvement, from 11.9 ± 1.9 to 13.1 ± 1.3 (p <0.001). All means of essential parameter evaluation scores were significantly improved in overall participants.The pediatric elbow radiographic guidance is useful for evaluation and diagnosis of lateral condyle fracture, especially for young physicians and trainees. Therefore, this should be recommended in routine medical education and general practice.


Subject(s)
Elbow Joint , Humeral Fractures, Distal , Humeral Fractures , Child , Humans , Elbow/diagnostic imaging , Cross-Sectional Studies , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Elbow Joint/diagnostic imaging , Fracture Fixation, Internal , Retrospective Studies
8.
Clin Imaging ; 109: 110118, 2024 May.
Article in English | MEDLINE | ID: mdl-38520814

ABSTRACT

BACKGROUND: The modified Gartland classification is an important tool for evaluation of pediatric supracondylar humerus fractures (SCHF) because it can direct treatment decisions. Gartland type I can be managed outpatient, while emergent surgical consult occurs with type II and III. This study assesses the interobserver reliability of the Gartland classification between pediatric radiologists and orthopedic providers. METHODS: A retrospective review of 320 children diagnosed with a SCHF at a single tertiary children's hospital during 2022 was conducted. The Gartland classification documented in the radiographic report by a pediatric radiologist and the classification documented in the first encounter with an orthopedic provider was collected. Kappa value was used to assess interobserver reliability of classifications between radiologists and orthopedic providers. A second group of 76 Gartland type I SCHF from 2015, prior to our institution's implementation of structured reporting, was reviewed for comparison of unnecessary orthopedic consults at initial presentation. RESULTS: The Gartland classification has excellent interobserver reliability between radiologists and orthopedic providers with 90 % (289/320) agreement and kappa of 0.854 (confidence interval: 0.805-0.903). The most frequent disagreement that occurred was fractures classified as type II by radiology and type III by orthopedics. There were similar rates of consults for the 2015 and 2022 cohorts (p = 0.26). CONCLUSION: The Gartland classification system is a reliable and effective tool for communication between radiologists and orthopedic providers. Implementing a structured reporting system has the potential to improve triage efficiency for SCHF.


Subject(s)
Humeral Fractures , Orthopedic Surgeons , Child , Humans , Reproducibility of Results , Triage , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Retrospective Studies , Radiologists , Humerus/diagnostic imaging , Treatment Outcome
9.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(3): 278-283, 2024 Mar 15.
Article in Chinese | MEDLINE | ID: mdl-38500419

ABSTRACT

Objective: To compare the effectiveness of ultrasound-guided closed reduction and Kirschner wire fixation for different unstable humeral lateralcondylar fractures of children. Methods: The clinical data of 94 children with unstable humeral lateralcondylar fractures admitted to three medical centers between January 2021 and October 2022 were retrospectively analyzed. The children were divided into three groups according to the Song classification and whether the elbow joint was dislocated or not, including 42 cases of Song 4 type (group A), 38 cases of Song 5 type (group B), and 14 cases of elbow joint dislocation (group C). There was no significant difference in gender, age, side, cause of injury, and time from injury to operation among the three groups ( P>0.05). All children were treated with ultrasound-guided closed reduction and Kirschner wire fixation. The operation time and complications of the three groups were recorded and compared, and the failure of closed reduction was evaluated by ultrasound. X-ray examination was performed at last follow-up to measure the Baumann angle, condylar angle, carrying angle, and lateral osteophyte of the affected side; the extension, flexion, pronation, and supination range of motion of the affected elbow joint were measured; the function of the elbow joint was evaluated by Mayo score. Results: The operation time in group A was significantly longer than that in groups B and C ( P<0.05). There were 7, 2, and 5 cases of closed reduction failure in groups A, B, and C, respectively, and there was no significant difference in the incidence of the closed reduction failure ( P>0.05). All patients were followed up 6-28 months, with an average of 15.7 months. There was no significant difference in the follow-up time among the three groups ( P>0.05). Complications: in group A, there were 2 cases of delayed union, 4 cases of needle tract infection, 1 case of trochlear necrosis, and 39 cases of lateral osteophyte; in group B, there was 1 case of malunion, 5 cases of needle tract infection, 1 case of redisplacement, and 26 cases of lateral osteophyte; in group C, there were 2 cases of needle tract infection and 10 cases of lateral osteophyte. There was no significant difference in the incidence of complications among the three groups ( P>0.05). No cubitus varus or cubitus valgus deformity was found in all patients. At last follow-up, except that the condylar angle in group A was significantly greater than that in groups B and C ( P<0.05), there was no significant difference in other imaging indicators, elbow range of motion, or Mayo score between groups ( P>0.05). Conclusion: The Song type 4 of humeral lateralcondylar fracture treated with ultrasound-guided closed reduction and Kirschner wire fixation has a longer operation time, more postoperative complications, and is more prone to lateral osteophyte.


Subject(s)
Humeral Fractures , Osteophyte , Child , Humans , Bone Wires , Fracture Fixation, Internal/methods , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Humerus , Osteophyte/complications , Range of Motion, Articular , Retrospective Studies , Treatment Outcome , Ultrasonography, Interventional , Male , Female
10.
Bull Hosp Jt Dis (2013) ; 82(1): 85-90, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38431982

ABSTRACT

The association of radial nerve palsy and humeral shaft fracture is well known. Primary exploration and fracture fixation is recommended for open fractures and vascular injury while expectant management remains the standard of care for closed injuries. In the absence of nerve recovery, exploration and reconstruction is recommended 3 to 5 months following injury. When direct repair or nerve grafting is unlikely to achieve a suitable outcome, nerve and tendon transfers are potential options for the restoration of wrist and finger extension.


Subject(s)
Humeral Fractures , Radial Neuropathy , Humans , Radial Neuropathy/diagnosis , Radial Neuropathy/etiology , Radial Neuropathy/surgery , Radial Nerve , Fingers , Humeral Fractures/complications , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Humerus
13.
J Orthop Surg Res ; 19(1): 113, 2024 Feb 02.
Article in English | MEDLINE | ID: mdl-38308347

ABSTRACT

BACKGROUND: This study employs an innovative closed reduction approach to treat pediatric "Irreducible Supracondylar Humerus Fractures" with the goal of demonstrating its practical application compared to conventional methods. METHODS: This study sampled 146 surgically treated cases of "Irreducible Supracondylar Humerus Fractures" in our department. After applying inclusion and exclusion criteria, 120 children were selected and divided into two groups based on treatment methods. Group 1 underwent Closed Reduction and Percutaneous Pinning (CRPP), while Group 2 received treatment using the Kirschner Wire Prying and Leverage Technique alongside CRPP. The relevant data to the study were collected and assessed during the follow-up period. RESULTS: Results indicate that Group 2 demonstrated significantly shorter operative times and fewer instances of intraoperative fluoroscopy compared to Group 1. Furthermore, the percentage of cases requiring open reduction was notably higher in Group 1 than in Group 2. The analysis also identified age, BMI, time from injury to surgery, and the initial deviation of the distal fragment as independent risk factors associated with the failure of closed reduction. The integration of CRPP with the Kirschner Wire Prying and Leverage Technique emerges as a safe and effective strategy for managing "Irreducible Supracondylar Humerus Fractures." This innovative approach not only reduces operative time and intraoperative fluoroscopy needs but also diminishes the reliance on open reduction without compromising safety.


Subject(s)
Bone Wires , Humeral Fractures , Child , Humans , Fracture Fixation, Internal/methods , Retrospective Studies , Humerus/surgery , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Treatment Outcome
14.
Eur Rev Med Pharmacol Sci ; 28(3): 924-930, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38375697

ABSTRACT

OBJECTIVE: Floating elbow, which refers to a humerus fracture in the supracondylar region and a forearm fracture, is a very unusual injury. The purpose of this study is to compare the clinical results of patients with "floating elbows" who underwent surgical therapy and who were given forearm immobilization with a splint as follow-up care. PATIENTS AND METHODS: Fifteen patients who had been diagnosed with floating elbow owing to trauma were scanned retrospectively and followed up for at least a year. Eight individuals who suffered from broken forearms underwent surgical repair. After initial treatment, a lengthy arm splint was used to immobilize seven patients' arms. The modified Flynn criteria were used to analyze the data, and comparisons were made between the groups. RESULTS: The median age and mean follow-up time for patients whose forearms were conservatively followed was 6.1 years and 13.8 months, respectively. The median age of the patients who underwent forearm surgery was 8.5 years, and the average follow-up was 14.2 months. Five of the seven patients whose forearms underwent conservative follow-up had outstanding clinical outcomes, while two had poor and moderate outcomes. Four individuals who got surgical treatment for their forearms had excellent and good clinical outcomes, while the other four had intermediate and poor outcomes. Between the two groups, there was no discernible difference (p = 0.60). CONCLUSIONS: In the pediatric population with floating elbow injuries, using a cast for forearm fractures may not necessarily result in worse outcomes compared to surgical management.


Subject(s)
Elbow Injuries , Elbow Joint , Forearm Injuries , Humeral Fractures , Humans , Child , Forearm/surgery , Retrospective Studies , Conservative Treatment , Forearm Injuries/surgery , Forearm Injuries/epidemiology , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Treatment Outcome , Elbow Joint/diagnostic imaging , Elbow Joint/surgery
15.
J Orthop Surg Res ; 19(1): 53, 2024 Jan 11.
Article in English | MEDLINE | ID: mdl-38212796

ABSTRACT

BACKGROUND: Managing distal humeral fractures can be challenging for orthopedic surgeons. There are several treatment options for managing this type of fracture, and the treatment method for these fractures should be based on patient-related factors. In elderly patients with osteoporotic bone and severe comminution of the fracture, adequate fixation can be a major challenge for surgeons. The use of megaprosthesis has been recently proposed in traumatology as an alternative to osteosynthesis or conventional prosthesis for the management of comminuted articular fractures in elderly patients with poor bone stock. METHODS: A consecutive case series of 5 patients who underwent reconstruction of the elbow joint with a trabecular hinged modular elbow megaprosthesis was reviewed retrospectively. All patients included had AO/OTA 13C2 and 13C3 fractures with metaphyseal extension and considerable bone loss of the distal humerus. The primary outcome was the evaluation of functional and clinical outcomes with the MEPS score in comminuted distal humerus fractures with metaphyseal extension and poor bone stock in elderly patients treated with elbow megaprosthesis. The secondary outcome was assessing the treatment-related complication rate of this technique in non-oncological fields. RESULTS: Five patients were included in the study with a mean age of 82.66 ± 7.72 years at surgery. The mean MEPS value was 63 ± 24.2 at 1 month, 81 ± 23.53 at 3 months, 83 ± 24.2 at 6 months, and 84 ± 24.57 at 12 months. No intraoperative complications were recorded in our series. Of 5 patients, four patients had excellent clinical and functional outcomes. We did not encounter wound dehiscence, prosthetic joint infection, aseptic loosening, or periprosthetic fractures. CONCLUSIONS: The indication for this type of treatment must be selected and narrowed down, as it is a salvage procedure, and any failure would cause even more complex situations. Short operating times and early mobilization of the elbow are the advantages of this technique.


Subject(s)
Elbow Joint , Fractures, Comminuted , Humeral Fractures, Distal , Humeral Fractures , Humans , Aged , Aged, 80 and over , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Retrospective Studies , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Treatment Outcome , Humerus , Fracture Fixation, Internal/methods , Fractures, Comminuted/diagnostic imaging , Fractures, Comminuted/surgery , Range of Motion, Articular
16.
BMC Musculoskelet Disord ; 25(1): 56, 2024 Jan 12.
Article in English | MEDLINE | ID: mdl-38216954

ABSTRACT

BACKGROUND: To analyze the clinical efficacy of K-wire placement guided technology in paediatric supracondylar humerus fractures. METHODS: A retrospective study was conducted in 105 patients who underwent closed reduction and percutaneous pinning surgeries in our hospital from June 2019 to August 2022. 54 patients treated with a assisted reduction fixation device to assist in closed reduction and percutaneous K-wire cross-fixation were allocated into the Non-guided group, and 51 patients with K-wire placement guided technology to guide K-wire placement were assigned into the Guided group. The operation duration, number of disposable K-wire placement, intraoperative fluoroscopy frequency, Baumann angle, carrying angle, fracture healing time and Flynn score of elbow joint function at the final follow-up were compared between two groups. The postoperative complications of two groups were recorded. RESULTS: There were significant differences between two groups in terms of operation duration, intraoperative fluoroscopy frequency, and disposable K-wire placement rate (p < 0. 05), while no significant differences of Baumann angle, carrying angle and the fracture healing time between two groups were observed (p > 0. 05). In the control group, ulnar nerve injury in 2 case, pin site infection in 4 cases, mild cubitus varus in 2 cases and loss of reduction in 4 cases were detected. In the study group, ulnar nerve injury in 1 case, pin site infection in 2 cases and loss of reduction in 1 case was observed. There was no significant difference in Flynn scores between two groups. CONCLUSION: K-wire placement guided technology is simple and convenient. The application of K-wire placement guided technology could relatively improved disposable K-wire placement rate, shorten the intraoperative fluoroscopy frequencies and reduce complication rates.


Subject(s)
Bone Wires , Humeral Fractures , Child , Humans , Retrospective Studies , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Fluoroscopy , Fracture Fixation, Internal/adverse effects , Treatment Outcome , Technology , Humerus
17.
J Orthop Surg Res ; 19(1): 26, 2024 Jan 03.
Article in English | MEDLINE | ID: mdl-38167111

ABSTRACT

PURPOSE: In this study, we aimed to investigate the effects of postoperative malrotation alignment on the outcomes of Gartland type III/IV paediatric supracondylar humeral fracture (SCHF) treated by close reduction and percutaneous K-wire fixation. METHODS: Between January 2014 and December 2021, 295 Gartland type III/IV paediatric SCHFs treated by close reduction and percutaneous K-wire fixation were selected for this retrospective study. The demographic, clinical and radiographic parameters of all cases were collected. The lateral rotation percentage (LRP) was measured on X-rays to evaluate postoperative malrotation alignment of the fracture. All cases were categorized into 4 groups according to LRP: LRP ≤ 10% (210, 71.2%), 10% < LRP ≤ 20% (41, 13.9%), 20% < LRP ≤ 30% (26, 8.8%) and LRP > 30% (18, 6.1%). The carrying angle, ranges of multidirectional motions, Mayo Elbow Performance Score (MEPS) and Flynn's Standard Score (FSS) of the injured elbow were assessed 6 months postoperation and compared among different groups. ROC analysis based on LRP and the excellent/good rate of FSS was performed to determine the acceptable maximum degree of postoperative malrotation alignment. RESULTS: There was no difference in the demographic characteristics (age, sex, injured side and fracture type), postoperative Baumann angle, carrying angle or range of forearm rotation among the 4 groups (P > 0.05). The operation time and time from operation to K-wire removal were longer in the 20% < LRP ≤ 30% and LRP > 30% groups than in the LRP < 10% and 10% < LRP ≤ 20% groups (P < 0.001). The shaft condylar angle, range of elbow flexion, MEPS and FSS of the injured elbow 6 months postoperatively were lower in the 20% < LRP ≤ 30% and LRP > 30% groups than in the LRP < 10% and 10% < LRP ≤ 20% groups (P < 0.001). ROC analysis based on LRP and the excellent/good rate of FSS showed an area under the curve of 0.959 (95% CI 0.936-0.983), with a cutoff value of 26.5%, sensitivity of 95.3% and specificity of 90.1%. CONCLUSION: A certain degree of residual malrotation alignment deformity of the SCHF may reduce the shaft condylar angle and extend the time from operation to removing the K-wire and affect elbow function, especially the range of elbow flexion. The acceptable maximum degree of residual malrotation deformity expressed as the LRP value was 26.5%.


Subject(s)
Bone Wires , Humeral Fractures , Child , Humans , Retrospective Studies , Treatment Outcome , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Rotation , Fracture Fixation, Internal
18.
Injury ; 55(3): 111309, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38199074

ABSTRACT

INTRODUCTION: Lateral humeral condyle fractures (LHCFs) are the most common intra-articular fracture occurring at the elbow in children. Conventional treatment for displaced pediatric LHCFs is open reduction and percutaneous pinning, and few studies have regarded the efficacy of arthroscopic-assisted techniques. We aimed to evaluate the efficacy of anatomic reduction via elbow arthroscopy for pediatric humeral lateral condyle fractures with displacements >4 mm. METHODS: A total of 32 children with LHCFs featuring displacements >4 mm were enrolled in this retrospective study. Arthroscopically assisted reduction was performed as the primary treatment approach. For simple displaced fractures, arthroscopically assisted reduction was directly employed with intermittent intra-articular irrigation. For fractures with distal fragment rotation, the rotated fragments were firstly realigned into a simple displaced position under fluoroscopy before proceeding with arthroscopy. The success rate of arthroscopically assisted reduction and clinical outcomes at the latest follow-up were assessed, and complications related to the procedure were monitored. RESULTS: Twenty-nine of 32 (90.62 %) enrolled cases were successfully treated with arthroscopically assisted reduction. Failure cases were attributed to soft tissue swelling, which hindered the manipulation of the fracture fragments for reduction or fixation. We subsequently adapted the surgical procedure, resulting in a significant increase in the success of arthroscopically assisted reduction, rising from 71.43 % to 96 %. Among the 29 successfully treated cases, excellent functional outcomes were observed in 18 cases, and 11 cases showed good outcomes. Regarding the carrying angle outcomes, 28 patients achieved excellent results, with one patient having a good outcome. The most frequent radiographic finding after surgery was lateral spur formation without further negative effects. Only one case of superficial infection occurred, promptly healing with topical management. No significant complications such as neurovascular injury or compartment syndrome were observed. CONCLUSION: Arthroscopically assisted anatomic reduction provides a promising alternative to open reduction for LHCFs with displacements exceeding 4 mm, offering direct visualization of the articular surface and minimizing soft tissue dissection.


Subject(s)
Fracture Fixation, Intramedullary , Humeral Fractures, Distal , Humeral Fractures , Joint Diseases , Humans , Child , Fracture Fixation, Internal/methods , Retrospective Studies , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Fracture Fixation, Intramedullary/methods , Treatment Outcome
19.
BMJ Case Rep ; 17(1)2024 Jan 29.
Article in English | MEDLINE | ID: mdl-38286584

ABSTRACT

A child sustained an ipsilateral supracondylar humerus (SCH) and distal both-bone forearm fractures bilaterally, in addition to facial injuries, following a fall from height. He was managed surgically by closed reduction and pinning for both SCH and distal end radius fractures bilaterally. At the final follow-up, all the fractures had united uneventfully, and he had no functional limitations or cosmetic concerns. We conclude that a floating elbow in the paediatric population is an uncommon injury, and the bilateral scenario is even rarer. One should be vigilant for compartment syndrome; early surgical fixation may give better results.


Subject(s)
Elbow Injuries , Humeral Fractures , Radius Fractures , Male , Humans , Child , Elbow/diagnostic imaging , Humeral Fractures/complications , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Forearm , Radius Fractures/complications , Radius Fractures/diagnostic imaging , Radius Fractures/surgery , Fracture Fixation, Internal/methods , Treatment Outcome , Retrospective Studies
20.
J Pediatr Orthop B ; 33(2): 167-173, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37158126

ABSTRACT

OBJECTIVES: The primary objective of the present study is to compare the radiographic outcomes and complications of two different techniques for lateral closing-wedge osteotomy in pediatric patients with cubitus varus. METHODS: We retrospectively identified patients treated at five tertiary care institutions: 17 underwent the Kirschner-wire (KW) technique, and 15 patients were treated with the mini external fixator (MEF) technique. Demographic data, previous treatment, pre- and postoperative carrying angle (CA), complications and additional procedures were recorded. Radiographic evaluation included assessment of the humerus-elbow-wrist angle (HEW), and the lateral prominence index (LPI). RESULTS: Patients treated with both KW and MEF achieved significant improvements in clinical alignment (mean pre-op CA -16 ± 6.1 degrees to mean post-op 8.9 ± 5.3 degrees, P < 0.001). There were no differences in final radiographic alignment or radiographic union time; however, time to achieve full elbow motion was faster in the MEF group (13.6 versus 34.3 weeks, P = 0.4547). Two patients (11.8%) in the KW group experienced complications, including one superficial infection and one failed correction that required unplanned revision surgery. Eleven patients in the MEF group underwent a planned second surgical procedure for hardware removal. CONCLUSIONS: Both fixation techniques are effective at correcting cubitus varus in the pediatric population. The MEF technique may have the advantage of shorter recovery of elbow range of motion but may require sedation for hardware removal. The KW technique may present a slightly higher complication rate.


Subject(s)
Elbow Joint , Humeral Fractures , Joint Deformities, Acquired , Humans , Child , Humeral Fractures/complications , Humeral Fractures/diagnostic imaging , Humeral Fractures/surgery , Retrospective Studies , Treatment Outcome , Joint Deformities, Acquired/diagnostic imaging , Joint Deformities, Acquired/surgery , Osteotomy/methods , Elbow Joint/diagnostic imaging , Elbow Joint/surgery , Range of Motion, Articular
SELECTION OF CITATIONS
SEARCH DETAIL
...