Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.220
Filter
1.
BMC Cancer ; 24(1): 1041, 2024 Aug 22.
Article in English | MEDLINE | ID: mdl-39174903

ABSTRACT

BACKGROUND AND PURPOSE: Ir192 vaginal brachytherapy (IBT) is commonly used for patients with postoperative endometrial cancer (EC). We devised a novel multichannel vaginal applicator that could be equipped with an electronic brachytherapy (EBT) device. We aimed to explore the differences in physical parameters between the EBT and IBT. MATERIALS AND METHODS: This retrospective study included 20 EC patients who received adjuvant IBT from March 1, 2023, to May 1, 2023. Multichannel vaginal cylinders were used, and three-dimensional plans were generated. We designed an electronic multichannel vaginal applicator model and simulated a three-dimensional EBT plan. In order to ensure comparability, D90 of the CTV for the EBT plan was normalized to be equivalent to that of the IBT plan for the same patient. RESULTS: Twenty EBT plans were compared with 20 IBT plans. Results showed, the mean D90 value of clinical target volume (CTV) was 536.1 cGy for both treatment plans. For the mean dose of CTV, the EBT was significantly greater (738.3 vs. 684.3 cGy, p = 0.000). There was no significant difference in CTV coverage between the EBT and IBT plans. For high-dose areas (V200% and V150%), the EBTs were significantly greater. There were no significant differences in the maximum doses to the vaginal mucosa between the EBT and IBT, whether at the apex or in the middle segment. For the bladder and rectum, both the low-dose area and high-dose area were significantly lower in the EBT plans. For the conformity index, there was no significant difference between the EBT and IBT plans. For the dose homogeneity index, the EBT value was lower. CONCLUSION: In conclusion, under the premise of a three-dimensional brachytherapy plan, for patients receiving multichannel vaginal applicator brachytherapy, compared with IBT, EBT could reduce the dose to the surrounding organs at risk while maintaining the dose in the target area.


Subject(s)
Brachytherapy , Endometrial Neoplasms , Iridium Radioisotopes , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Humans , Female , Brachytherapy/methods , Brachytherapy/instrumentation , Endometrial Neoplasms/radiotherapy , Endometrial Neoplasms/pathology , Retrospective Studies , Iridium Radioisotopes/therapeutic use , Radiotherapy Planning, Computer-Assisted/methods , Middle Aged , Aged , Radiometry , Organs at Risk/radiation effects
2.
Phys Med Biol ; 69(16)2024 Jul 30.
Article in English | MEDLINE | ID: mdl-39009012

ABSTRACT

Objective. To enhance the investigations on MC calculated beam quality correction factors of thimble ionization chambers from high-energy brachytherapy sources and to develop reliable reference conditions in source and detector setups in water.Approach. The response of five different ionization chambers from PTW-Freiburg and Standard Imaging was investigated for irradiation by a high dose rate Ir-192 Flexisource in water. For a setup in a Beamscan water phantom, Monte Carlo simulations were performed to calculate correction factors for the chamber readings. After exact positioning of source and detector the absorbed dose rate at the TG-43 reference point at one centimeter nominal distance from the source was measured using these factors and compared to the specification of the calibration certificate. The Monte Carlo calculations were performed using the restricted cema formalism to gain further insight into the chamber response. Calculations were performed for the sensitive volume of the chambers, determined by the methods currently used in investigations of dosimetry in magnetic fields.Main results. Measured dose rates and values from the calibration certificate agreed within the combined uncertainty (k= 2) for all chambers except for one case in which the full air cavity was simulated. The chambers showed a distinct directional dependence. With the restricted cema formalism calculations it was possible to examine volume averaging and energy dependence of the perturbation factors contributing to the beam quality correction factor also differential in energy.Significance. This work determined beam quality correction factors to measure the absorbed dose rate from a brachytherapy source in terms of absorbed dose to water for a variety of ionization chambers. For the accurate dosimetry of brachytherapy sources with ionization chambers it is advisable to use correction factors based on the sensitive volume of the chambers and to take account for the directional dependence of chamber response.


Subject(s)
Brachytherapy , Monte Carlo Method , Radiometry , Brachytherapy/instrumentation , Radiometry/instrumentation , Calibration , Radiotherapy Dosage , Phantoms, Imaging , Uncertainty , Water , Iridium Radioisotopes/therapeutic use
3.
J Cancer Res Ther ; 20(3): 930-934, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-39023600

ABSTRACT

INTRODUCTION: Surface mold brachytherapy (SMBT) is an established treatment modality in skin cancer, especially in accessible areas, and has shown comparable outcomes to surgery. We have presented our results for the skin tumor treatment with SMBT treated with high-dose-rate (HDR) brachytherapy in terms of clinical outcomes and toxicity at our institute. MATERIALS AND METHODS: In this retrospective analysis, 15 patients with skin cancer were treated with customized tube-based SMBT at our institute between January 2019 and July 2021. The patients were treated using HDR-brachytherapy using Iridium-192. The median dose was 40 Gy in 10 fractions. The dosimetric parameters were assessed, and patients were followed up as per the institutional protocol. All patients underwent individualized CT-based planning. Skin toxicity was assessed using the Dermatology Life Quality Index (DLQI). RESULTS: With the majority of the patients being male, the median age was 59 years and the most common site affected was the face (8/15; 53.3%). Among the 15 cases, five were squamous cell carcinoma, nine were basal cell carcinoma, and a single case of sebaceous cell carcinoma. The median depth of invasion was 4 mm, and the median catheter-to-surface distance was 1 mm. The complete response rate among the 10 definitive cases was 90% and partial response in one case. The treatment was well-tolerated with no grade 3-5 toxicities. The median V95% and V90% were 94.8% and 97.1%, respectively. The mean coverage index (C.I.), dose non-uniformity ratio (DNR), and overdose volume index (ODI) were 0.97, 0.13, and 0.05, respectively. After a median follow-up of 12 months, none of the patients had recurrence. On assessment of DLQI, the scores were found to be significant in association with the tumor size and tumor site with scores favoring <2 cm and non-exposed area lesions. CONCLUSION: SMBT is a safe and effective treatment modality for skin tumors providing excellent response and cosmetic outcomes. It is well-tolerated and a non-invasive option for elderly patients with comorbidities and lesions in inoperable areas.


Subject(s)
Brachytherapy , Radiotherapy Dosage , Skin Neoplasms , Humans , Brachytherapy/adverse effects , Brachytherapy/methods , Male , Middle Aged , Skin Neoplasms/radiotherapy , Skin Neoplasms/pathology , Female , Retrospective Studies , Aged , Adult , Iridium Radioisotopes/therapeutic use , Treatment Outcome , Radiotherapy Planning, Computer-Assisted/methods , Carcinoma, Basal Cell/radiotherapy , Carcinoma, Basal Cell/pathology , Follow-Up Studies , Carcinoma, Squamous Cell/radiotherapy , Carcinoma, Squamous Cell/pathology , Quality of Life
4.
Med Phys ; 51(7): 5094-5098, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38507246

ABSTRACT

BACKGROUND: Non-melanoma skin cancer is one of the most common types of cancer and one of the main approaches is brachytherapy. For small lesions, the treatment of this cancer with brachytherapy can be done with two commercial applicators, one of these is the Large Field Valencia Applicators (LFVA). PURPOSE: The aim of this study is to test the capabilities of the LFVA to use clinically 60Co sources instead of the 192Ir ones. This study was designed for the same dwell positions and weights for both sources. METHODS: The Penelope Monte Carlo code was used to evaluate dose distribution in a water phantom when a 60Co source is considered. The LFVA design and the optimized dwell weights reported for the case of 192Ir are maintained with the only exception of the dwell weight of the central position, that was increased. 2D dose distributions, field flatness, symmetry and the leakage dose distribution around the applicator were calculated. RESULTS: When comparing the dose distributions of both sources, field flatness and symmetry remain unchanged. The only evident difference is an increase of the penumbra regions for all depths when using the 60Co source. Regarding leakage, the maximum dose within the air volume surrounding the applicator is in the order of 20% of the prescription dose for the 60Co source, but it decreases to less than 5% at about 1 cm distance. CONCLUSIONS: Flatness and symmetry remains unaltered as compared with 192Ir sources, while an increase in leakage has been observed. This proves the feasibility of using the LFVA in a larger range of clinical applications.


Subject(s)
Brachytherapy , Cobalt Radioisotopes , Monte Carlo Method , Radiometry , Radiotherapy Dosage , Brachytherapy/instrumentation , Cobalt Radioisotopes/therapeutic use , Radiometry/instrumentation , Phantoms, Imaging , Iridium Radioisotopes/therapeutic use , Humans
5.
Biomed Phys Eng Express ; 10(3)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38507785

ABSTRACT

The aim of this study was to use computer simulation to analyze the impact of the aluminum fixing support on the Reference Air Kerma (RAK), a physical quantity obtained in a calibration system that was experimentally developed in the Laboratory of Radiological Sciences of the University of the State of Rio de Janeiro (LCR-UERJ). Correction factors due to scattered radiation and the geometry of the192Ir sources were also sought to be determined. The computational simulation was validated by comparing some parameters of the experimental results with the computational results. These parameters were: verification of the inverse square law of distance, determination of (RAKR), analysis of the source spectrum with and without encapsulation, and the sensitivity curve of the Sourcecheck 4PI ionization chamber response, as a function of the distance from the source along the axial axis, using the microSelectron-v2 (mSv2) and GammaMedplus (GMp) sources. Kerma was determined by activity in the Reference air, with calculated values of 1.725 × 10-3U. Bq-1and 1.710 × 10-3U. Bq-1for the ionization chamber NE 2571 and TN 30001, respectively. The expanded uncertainty for these values was 0.932% and 0.919%, respectively, for a coverage factor (k = 2). The correction factor due to the influence of the aluminum fixing support for measurements at 1 cm and 10 cm from the source was 0.978 and 0.969, respectively. The geometric correction factor of the sources was ksg= 1.005 with an expanded uncertainty of 0.7% for a coverage factor (k = 2). This value has a difference of approximately 0.2% compared to the experimental values.


Subject(s)
Computer Simulation , Iridium Radioisotopes , Radiometry , Calibration , Radiometry/methods , Iridium Radioisotopes/therapeutic use , Humans , Air , Aluminum , Monte Carlo Method , Radiation Dosage , Brachytherapy/methods , Brachytherapy/standards , Radiotherapy Dosage , Scattering, Radiation
6.
PLoS One ; 19(2): e0298550, 2024.
Article in English | MEDLINE | ID: mdl-38335156

ABSTRACT

After 2010, the source model of the microSelectron HDR Afterloader System was slightly modified from the previous model. Granero et al. named the modified source model "mHDR-v2r (revised model mHDR-v2)" and the previous model "mHDR-v2". They concluded that the dosimetric differences arising from the dimensional changes between the mHDR-v2 and mHDR-v2r designs were negligible at almost all locations (within 0.5% for r ≥ 0.25 cm), the two-dimensional anisotropy function difference between the two sources is found 2.1% at r = 1.0 cm when compared with the results of the other experimental group. To confirm this difference, we performed a full Monte Carlo simulation without energy-fluence approximation. This is useful near the radiation source where charged-particle equilibrium does not hold. The two-dimensional anisotropy function of the TG-43U1 dataset showed a few percent difference between the mHDR-v2r and mHDR-v2 sources. There was no agreement in the immediate vicinity of the source (0.10 cm and 0.25 cm), when compared to Granero et al. in mHDR-v2r sources. The differences in these two-dimensional anisotropy functions were identified.


Subject(s)
Brachytherapy , Brachytherapy/methods , Iridium Radioisotopes/therapeutic use , Radiotherapy Dosage , Monte Carlo Method , Radiometry/methods
7.
J Appl Clin Med Phys ; 25(1): e14228, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38043126

ABSTRACT

PURPOSE: To analytically assess the heterogeneity effect of vaginal cylinders (VC) made of high-density plastics on dose calculations, considering the prescription point (surface or 5 mm beyond the surface), and benchmark the accuracy of a commercial model-based dose calculation (MBDC) algorithm using Monte Carlo (MC) simulations. METHODS AND MATERIALS: The GEANT4 MC code was used to simulate a commercial 192 Ir HDR source and VC, with diameters ranging from 20 to 35 mm, inside a virtual water phantom. Standard plans were generated from a commercial treatment planning system [TPS-BrachyVision ACUROS (BV)] optimized for a treatment length of 5 cm through two dose calculation approaches: (1) assuming all the environment as water (i.e., Dw,w-MC & Dw,w-TG43 ) and (2) accounting for the heterogeneity of VC applicators (i.e., Dw,w-App-MC & Dw,w-App-MBDC ). The compared isodose lines, and dose & energy difference maps were extracted for analysis. In addition, the dose difference on the peripheral surface, along the applicator and at middle of treatment length, as well as apical tip was evaluated. RESULTS: The Dw,w-App-MC results indicated that the VC heterogeneity can cause a dose reduction of (up to) % 6.8 on average (for all sizes) on the peripheral surface, translating to 1 mm shrinkage of the isodose lines compared to Dw,w-MC . In addition, the results denoted that BV overestimates the dose on the peripheral surface and apical tip of about 3.7% and 17.9%, respectively, (i.e., Dw,w-App-MBDC vs Dw,w-App-MC ) when prescribing to the surface. However, the difference between the two were negligible at the prescription point when prescribing to 5 mm beyond the surface. CONCLUSION: The VCs' heterogeneity could cause dose reduction when prescribing dose to the surface of the applicator, and hence increases the level of uncertainty. Thus, reviewing the TG43 results, in addition to ACUROS, becomes prudent, when evaluating the surface coverage at the apex.


Subject(s)
Brachytherapy , Female , Humans , Radiotherapy Dosage , Brachytherapy/methods , Monte Carlo Method , Radiotherapy Planning, Computer-Assisted/methods , Iridium Radioisotopes/therapeutic use , Water , Radiometry
8.
Med Phys ; 50(10): 6525-6534, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37650773

ABSTRACT

BACKGROUND: High dose rate (HDR) brachytherapy is commonly used to treat prostate cancer. Existing HDR planning systems solve the dwell time problem for predetermined catheters and a single energy source. PURPOSE: Additional degrees of freedom can be obtained by relaxing the catheters' pre-designation and introducing more source types, and may have a dosimetric benefit, particularly in improving conformality to spare the urethra. This study presents a novel analytical approach to solving the corresponding HDR planning problem. METHODS: The catheter and dual-energy source selection problem was formulated as a constrained optimization problem with a non-convex group sparsity regularization. The optimization problem was solved using the fast-iterative shrinkage-thresholding algorithm (FISTA). Two isotopes were considered. The dose rates for the HDR 4140 Ytterbium (Yb-169) source and the Elekta Iridium (Ir-192) HDR Flexisource were modeled according to the TG-43U1 formalism and benchmarked accordingly. Twenty-two retrospective HDR prostate brachytherapy patients treated with Ir-192 were considered. An Ir-192 only (IRO), Yb-169 only (YBO), and dual-source (DS) plan with optimized catheter location was created for each patient with N catheters, where N is the number of catheters used in the clinically delivered plans. The DS plans jointly optimized Yb-169 and Ir-192 dwell times. All plans and the clinical plans were normalized to deliver a 15 Gy prescription (Rx) dose to 95% of the clinical treatment volume (CTV) and evaluated for the CTV D90%, V150%, and V200%, urethra D0.1cc and D1cc, bladder V75%, and rectum V75%. Dose-volume histograms (DVHs) were generated for each structure. RESULTS: The DS plans ubiquitously selected Ir-192 as the only treatment source. IRO outperformed YBO in organ at risk (OARs) OAR sparing, reducing the urethra D0.1cc and D1cc by 0.98% ( p = 2.22 ∗ 10 - 9 $p\ = \ 2.22*{10^{ - 9}}$ ) and 1.09% ( p = 1.22 ∗ 10 - 10 $p\ = \ 1.22*{10^{ - 10}}$ ) of the Rx dose, respectively, and reducing the bladder and rectum V75% by 0.09 ( p = 0.0023 $p\ = \ 0.0023$ ) and 0.13 cubic centimeters (cc) ( p = 0.033 $p\ = \ 0.033$ ), respectively. The YBO plans delivered a more homogenous dose to the CTV, with a smaller V150% and V200% by 3.20 ( p = 4.67 ∗ 10 - 10 $p\ = \ 4.67*{10^{ - 10}}$ ) and 1.91 cc ( p = 5.79 ∗ 10 - 10 $p\ = \ 5.79*{10^{ - 10}}$ ), respectively, and a lower CTV D90% by 0.49% ( p = 0.0056 $p\ = \ 0.0056$ ) of the prescription dose. The IRO plans reduce the urethral D1cc by 2.82% ( p = 1.38 ∗ 10 - 4 $p\ = \ 1.38*{10^{ - 4}}$ ) of the Rx dose compared to the clinical plans, at the cost of increased bladder and rectal V75% by 0.57 ( p = 0.0022 $p\ = \ 0.0022$ ) and 0.21 cc ( p = 0.019 $p\ = \ 0.019$ ), respectively, and increased CTV V150% by a mean of 1.46 cc ( p = 0.010 $p\ = \ 0.010$ ) and CTV D90% by an average of 1.40% of the Rx dose ( p = 8.80 ∗ 10 - 8 $p\ = \ 8.80*{10^{ - 8}}$ ). While these differences are statistically significant, the clinical differences between the plans are minimal. CONCLUSIONS: The proposed analytical HDR planning algorithm integrates catheter and isotope selection with dwell time optimization for varying clinical goals, including urethra sparing. The planning method can guide HDR implants and identify promising isotopes for specific HDR clinical goals, such as target conformality or OAR sparing.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Male , Humans , Brachytherapy/methods , Prostate , Retrospective Studies , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Iridium Radioisotopes/therapeutic use , Prostatic Neoplasms/radiotherapy , Prostatic Neoplasms/drug therapy , Catheters
9.
Sensors (Basel) ; 23(7)2023 Mar 30.
Article in English | MEDLINE | ID: mdl-37050652

ABSTRACT

Surface brachytherapy (BT) lacks standard quality assurance (QA) protocols. Commercially available treatment planning systems (TPSs) are based on a dose calculation formalism that assumes the patient is made of water, resulting in potential deviations between planned and delivered doses. Here, a method for treatment plan verification for skin surface BT is reported. Chips of thermoluminescent dosimeters (TLDs) were used for dose point measurements. High-dose-rate treatments were simulated and delivered through a custom-flap applicator provided with four fixed catheters to guide the Iridium-192 (Ir-192) source by way of a remote afterloading system. A flat water-equivalent phantom was used to simulate patient skin. Elekta TPS Oncentra Brachy was used for planning. TLDs were calibrated to Ir-192 through an indirect method of linear interpolation between calibration factors (CFs) measured for 250 kV X-rays, Cesium-137, and Cobalt-60. Subsequently, plans were designed and delivered to test the reproducibility of the irradiation set-up and to make comparisons between planned and delivered dose. The obtained CF for Ir-192 was (4.96 ± 0.25) µC/Gy. Deviations between measured and TPS calculated doses for multi-catheter treatment configuration ranged from -8.4% to 13.3% with an average of 0.6%. TLDs could be included in clinical practice for QA in skin BT with a customized flap applicator.


Subject(s)
Brachytherapy , Humans , Brachytherapy/methods , Reproducibility of Results , Iridium Radioisotopes/therapeutic use , Radiotherapy Dosage , Thermoluminescent Dosimetry , Water , Radiometry
10.
Appl Radiat Isot ; 196: 110751, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36871495

ABSTRACT

The present study was conducted to elucidate the effects of hip prostheses in 192Ir HDR brachytherapy and determine dose uncertainties introduced by the treatment planning. A gynaecological phantom irradiated using Nucletron 192Ir microSelectron HDR source was modeled using MCNP5 code. Three hip materials considered in this study were water, bone, and metal prosthesis. According to the obtained results, a dose perturbation was observed within the medium with a higher atomic number, which reduced the dose to the nearby region.


Subject(s)
Brachytherapy , Hip Prosthesis , Brachytherapy/methods , Radiotherapy Dosage , Iridium Radioisotopes/therapeutic use , Monte Carlo Method , Metals
11.
J Cancer Res Ther ; 19(Suppl 2): S477-S484, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-38384008

ABSTRACT

ABSTRACTS: A key challenge in radiation therapy is to maximize the radiation dose to cancer cells while minimizing damage to healthy tissues. In recent years, the introduction of remote after-loading technology such as high-dose-rate (HDR) brachytherapy becomes the safest and more precise way of radiation delivery compared to classical low-dose-rate (LDR) brachytherapy. However, the axially symmetric dose distribution of HDR with single channel cylindrical applicator, the physical "dead-space" with multichannel applicators, and shielding material heterogeneities are the main challenges of HDR brachytherapy. Thus, this review aimed to quantitatively evaluate the dose enhancement factor (DEF) produced by high atomic number nanoparticles (NPs) which increases the interaction probability of photons mainly through the photoelectric effect induced in the great number of atoms contained in each nanoparticle. The NPs loaded to the target volume create a local intensification effect on the target tissue that allows imparting the prescribed therapeutic dose using lower fluxes of irradiation and spare the surrounding healthy tissues. An electronic database such as PubMed/Medline, Embase, Scopus, and Google Scholar was searched to retrieve the required articles. Unpublished articles were also reached by hand from available sources. The dose is increased using the high atomic number of nanoparticle elements under the high dose iridium radionuclide whereas the cobalt-60 radionuclide source did not. However, much work is required to determine the dose distribution outside the target organ or tumor to spare the surrounding healthy tissues for the iridium source and make compressive work to have more data for the cobalt source.


Subject(s)
Brachytherapy , Cobalt Radioisotopes , Iridium Radioisotopes , Nanoparticles , Neoplasms , Radiotherapy Dosage , Humans , Iridium Radioisotopes/therapeutic use , Neoplasms/radiotherapy , Brachytherapy/methods , Nanoparticles/chemistry , Nanoparticles/administration & dosage
12.
Radiat Oncol ; 17(1): 206, 2022 Dec 13.
Article in English | MEDLINE | ID: mdl-36514118

ABSTRACT

BACKGROUND: High-dose-rate (HDR) intracavitary-interstitial brachytherapy (IC-ISBT) is an effective treatment for bulky, middle, and advanced cervical cancer. In this study, we compared the differences between 60Co and 192Ir HDR IC-ISBT plans in terms of radiobiological and dosimetric parameters, providing a reference for clinical workers in brachytherapy. METHODS: A total of 30 patients with cervical cancer receiving HDR IC-ISBT were included in this study, and IC-ISBT plans for each individual were designed with both 60Co and 192Ir at a prescribed dose of CTV D90 = 6 Gy while keeping the dose to OARs as low as possible. Physical dose and dose-volume parameters of CTV and OARs were extracted from TPS. The EQD2, EUBED, EUD, TCP, and NTCP were calculated using corresponding formulas. The differences between the 60Co and 192Ir IC-ISBT plans were compared using the paired t-test. RESULTS: In each patient's 60Co and 192Ir IC-ISBT plan, the average physical dose and EQD2 of 60Co were lower than those of 192Ir, and there were statistically significant differences in D2cc and D1cc for the OARs (p < 0.05); there were statistically significant differences in D0.1 cc for the bladder (p < 0.05) and no significant differences in D0.1 cc for the rectum or intestines (p > 0.05). The EUBED ratio (60Co/192Ir) at the CTV was mostly close to 1 when neither 60Co or 192Ir passed their half-lives or when both passed two half-lives, and the difference between them was not significant; at the OARs, the mean value of 60Co was lower than that of 192Ir. There was no statistical difference between 60Co and 192Ir in the EUD (93.93 versus 93.92 Gy, p > 0.05) and TCP (97.07% versus 97.08%, p > 0.05) of the tumors. The mean NTCP value of 60Co was lower than that of 192Ir. CONCLUSIONS: Considering the CTV and OARs, the dosimetric parameters of 60Co and 192Ir are comparable. Compared with 192Ir, the use of 60Co for HDR IC-ISBT can ensure a similar tumor control probability while providing better protection to the OARs. In addition, 60Co has obvious economic advantages and can be promoted as a good alternative to 192Ir.


Subject(s)
Brachytherapy , Uterine Cervical Neoplasms , Female , Humans , Uterine Cervical Neoplasms/radiotherapy , Uterine Cervical Neoplasms/pathology , Cobalt Radioisotopes/therapeutic use , Radiotherapy Dosage , Iridium Radioisotopes/therapeutic use , Organs at Risk/pathology , Radiotherapy Planning, Computer-Assisted
13.
Probl Radiac Med Radiobiol ; 27: 455-473, 2022 Dec.
Article in English, Ukrainian | MEDLINE | ID: mdl-36582109

ABSTRACT

BACKGROUND: Rapid development of radiotherapeutic techniques and implementation of radiation therapy (RT) nanotechnologies in practice, taking into account principles of radiobiology, ensures that the planned dose will bedelivered to the target volume with minimal irradiation of healthy tissues while maintaining the guaranteed RTquality. Therefore, further advance of RT involves not only implementation of the new technologies in radiationpractice, but also the intensive developments in fields of radiation medicine and clinical radiobiology. OBJECTIVE: search for optimal models of the high-energy (HDR - high dose rate) brachytherapy (BT) using the 192Irsource in comparison with effects of the reference gamma radiation from 60Co, thereby, to increase the effectivenessof chemoradiation therapy (CRT) of gynecological cancer patients (GCPs) with minimal radiation loads on criticalorgans and tissues in the tumor environment. The radiobiological study was aimed to determine the feasibility ofusing the transmembrane potential (TMP) and intensity of reactive oxygen species (ROS) production in peripheralblood lymphocytes (PBL) as predictors of radiosensitivity of non-malignant cells from the tumor environment or itsbed in order to minimize the RT complications in GCPs. MATERIALS AND METHODS: Patients (n = 115) with cancer stages II-III, T2-3N0-1M0 were managed with comprehensiveconservative treatment. Three groups of patients were selected depending on the applied HDR BT method against abackground of the administered chemosensitizing agents. Blood samples of GCPs (n = 24) before the RT initiationand of apparently healthy individuals (AHIs, i.e. the control group, n = 18) were taken for the radiobiologicalresearch. RESULTS: Review of the direct results of 60Co or 192Ir sources use in HDR BT and of the follow-up data showed theincreased tumor positive response in the main study groups after CRT course by respectively 16.6 % and 20.1 % incomparison with 60Со HDR BT administration. Concerning local reactions it was noted that grade II radiation reactions were almost absent in the main groups. According to the results of radiobiological studies, it was establishedthat TMP level in PBL of GCPs was 1.36 times higher than in AHIs. CONCLUSIONS: Thus, the emerging of late radiation injuries depended on the accuracy of of individual computer planning and correct reproduction of the planned RT course, timely correction of treatment programs, use of a complexof rational medical prophylaxis, severity of tumor process and concomitant disorders, as well as on the used type ofHDR radiation sources (192Ir and 60Co). Changes in TMP values and intensity of ROS production in PBL of GCPs in comparison with AHIs, and the high values of these parameters in PBL of individual patients are a rationale to specifythem as additional indicators characterizing the possibility of radiation complications before the RT planning.


Subject(s)
Brachytherapy , Neoplasms , Radiation Injuries , Humans , Iridium Radioisotopes/therapeutic use , Reactive Oxygen Species , Neoplasms/etiology , Radiation Injuries/therapy , Radiation Injuries/drug therapy , Brachytherapy/adverse effects , Brachytherapy/methods
14.
Phys Med ; 103: 66-73, 2022 Nov.
Article in English | MEDLINE | ID: mdl-36244135

ABSTRACT

PURPOSE: Although real-time imaging of the high-activity iridium-192 (Ir-192) source position during high-dose-rate (HDR) brachytherapy using a high-energy gamma camera system is a promising approach, the energy window was not optimized for spatial resolution or scatter fraction. METHODS: By using a list-mode data-acquisition system that can acquire energy information of a cerium-doped yttrium aluminum perovskite (YA1O3: YAP(Ce)) gamma camera, we tried to optimize the energy window's setting to improve the spatial resolution and reduce scatter fraction. RESULTS: The spatial resolution was highest for the central energy of the window at ∼300 keV. The scatter fraction was also smallest for the central energy of the window at ∼300 keV, and the scatter fraction was more than 48 % smaller than that for the full energy window. CONCLUSIONS: We clarified that the spatial resolution can be improved and the scatter fraction can be reduced through optimizing the energy window of the YAP(Ce) gamma camera by setting the central energy of the window to ∼300 keV for HDR brachytherapy.


Subject(s)
Brachytherapy , Gamma Cameras , Iridium Radioisotopes/therapeutic use , Phantoms, Imaging
15.
Med Phys ; 49(12): 7703-7714, 2022 Dec.
Article in English | MEDLINE | ID: mdl-36063027

ABSTRACT

PURPOSE: Measurement of the dwell time and moving speed of a high-activity iridium-192 (Ir-192) source used for high-dose-rate (HDR) brachytherapy is important for estimating the precise dose delivery to a tumor. For this purpose, we used a cerium-doped yttrium aluminum perovskite (YA1O3 :YAP(Ce)) gamma camera system, combined with a list-mode data acquisition system that can acquire short-time sequential images, and measured the dwell times and moving speeds of the Ir-192 source. METHODS: Gamma photon imaging was conducted using the gamma camera in list mode for the Ir-192 source of HDR brachytherapy with fixed dwell times and positions. The acquired list-mode images were sorted to millisecond-order interval time sequential images to evaluate the dwell time at each position. Time count rate curves were derived to calculate the dwell time at each source position and moving speed of the source. RESULTS: We could measure the millisecond-order time sequential images for the Ir-192 source. The measured times for the preset dwell times of 2 s and 10 s were 1.98 to 2.00 s full width at half maximum (FWHM) and 10.0 s FWHM, respectively. The dwell times at the first dwell position were larger than those at other positions. We also measured the moving speeds of the source after the dwells while moving back to the afterloader and found the speed increased with the distance from the edge of the field of view to the last dwell position. CONCLUSION: We conclude that millisecond-order time sequential imaging of the Ir-192 source is possible by using a gamma camera and is useful for evaluating the dwell times and moving speeds of the Ir-192 source.


Subject(s)
Brachytherapy , Radiotherapy Dosage , Brachytherapy/methods , Iridium Radioisotopes/therapeutic use , Diagnostic Imaging
16.
Cancer Radiother ; 26(8): 1075-1077, 2022 Nov.
Article in English | MEDLINE | ID: mdl-35843781

ABSTRACT

The purpose of this article is to remind the importance of the inverse square law in radiotherapy and especially in brachytherapy. Indeed, beyond the impact in radiation therapy with high energy beam, there is the use of radionuclides and low energy photons with short FSD where it is still more important. Comparisons between Iridium Brachytherapy and low energy X-rays brachytherapy show equivalent dose distributions in the first few centimeters. If the inverse square law is not the only element influencing the dose distributions calculations, it must not be forgotten. And it is playing a major role in brachytherapy with short FSD (<6cm).


Subject(s)
Brachytherapy , Radiation Oncology , Humans , Photons/therapeutic use , Radioisotopes/therapeutic use , X-Rays , Radiotherapy Dosage , Iridium Radioisotopes/therapeutic use
17.
Appl Radiat Isot ; 187: 110332, 2022 Sep.
Article in English | MEDLINE | ID: mdl-35717903

ABSTRACT

Magnetic resonance imaging (MRI) during brachytherapy may alter the dose distribution of radioactive sources implanted in the tumor. This study investigates the impact of a magnetic field of 1.5 T, 3 T, and 7 T strengths on the dose distribution of high dose rate Co-60, Ir-192, and Yb-169, and low dose rate I-125 sources, using Geant4 Monte Carlo toolkit. After validating the simulation results by calculating the AAPM-TG43 dosimetric parameters, seven sources of each radioisotope were simulated in a water phantom, and their dose distributions were compared under the influence of a magnetic field. The simulation results indicate that using Co-60 brachytherapy under the MRI guidance is not recommended. Furthermore, the impact of a magnetic field of up to 7 T strength on the dose distribution of Ir-192, Yb-169, and I-125 sources is negligible, provided that there is no air pocket near brachytherapy sources.


Subject(s)
Brachytherapy , Iridium Radioisotopes , Brachytherapy/methods , Cobalt Radioisotopes/therapeutic use , Iodine Radioisotopes , Iridium Radioisotopes/therapeutic use , Magnetic Fields , Monte Carlo Method , Radiometry/methods , Radiotherapy Dosage
18.
Med Phys ; 49(6): 3926-3935, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35403255

ABSTRACT

PURPOSE: High-dose-rate (HDR) vaginal cuff brachytherapy is an effective adjuvant therapy for women with stage I endometrial cancer. Although infrequent, failures do occur, most frequently at the vaginal vault. A potential cause of failure is insufficient dosimetric coverage at the vaginal apex due to cold spots from the anisotropic dose distribution of the source. Here, we propose a novel direction modulated brachytherapy (DMBT)-concept vaginal cylinder (VC) applicator that resolves this dosimetric issue. METHODS AND MATERIALS: The novel DMBT-VC applicator was designed and simulated with the GEANT4 Monte Carlo code. The outer cylinder material chosen was polyphenylsulfone (PPSU) plastic, and the central part was a detachable rod, housing a single lumen made of either polyether ether ketone (PEEK) plastic or an MR-compatible tungsten alloy. The PPSU-based outer cylinder, together with the inner PEEK rod provides the dose distribution of a conventional VC applicator. The PEEK rod is then replaced with an MR-compatible tungsten alloy rod of the same dimensions to generate directional "pencil-like" beams to compensate for the anisotropic cold spots. Two widely used 192 Ir HDR sources, VS2000 and GammaMedPlus, were also simulated. RESULTS: The novel DMBT-VC applicator was able to remove the underdosage at the apex due to the anisotropy effect regardless of the HDR sources without unnecessarily increasing the dose to the periphery of the applicator. Also, further directional modulation to reach deeper in the apex by up to 14 mm beyond the VC surface was achievable, again without increasing the peripheral doses. Total treatment dwell times increased only by 7-13%. CONCLUSIONS: The novel DMBT-VC applicator provides improved dose coverage at the vaginal apex by overcoming the classical anisotropy issue ubiquitous to all HDR brachytherapy sources. The next step in development of the device is manufacturing a prototype for clinical testing.


Subject(s)
Brachytherapy , Alloys , Female , Humans , Iridium Radioisotopes/therapeutic use , Monte Carlo Method , Plastics , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Tungsten
19.
Med Phys ; 49(7): 4715-4730, 2022 Jul.
Article in English | MEDLINE | ID: mdl-35443079

ABSTRACT

BACKGROUND: There is increased interest in in vivo dosimetry for 192 Ir brachytherapy (BT) treatments using high atomic number (Z) inorganic scintillators. Their high light output enables construction of small detectors with negligible stem effect and simple readout electronics. Experimental determination of absorbed-dose energy dependence of detectors relative to water is prevalent, but it can be prone to high detector positioning uncertainties and does not allow for decoupling of absorbed-dose energy dependence from other factors affecting detector response . PURPOSE: To investigate which measurement conditions and detector properties could affect their absorbed-dose energy dependence in BT in vivo dosimetry. METHODS: We used a general-purpose Monte Carlo (MC) code PENELOPE for the characterization of high-Z inorganic scintillators with the focus on ZnSe ( Z ¯ = 32 $\bar{Z}=32$ ) Z. Two other promising media CsI ( Z ¯ = 54 $\bar{Z}=54$ ) and Al2 O3 ( Z ¯ = 11 $\bar{Z}=11$ ) were included for comparison in selected scenarios. We determined absorbed-dose energy dependence of crystals relative to water under different scatter conditions (calibration phantom 12 × 12 × 30 cm3 , characterization phantoms 20 × 20 × 20 cm3 , 30 × 30 × 30 cm3 , 40 × 40 × 40 cm3 , and patient-like elliptic phantom 40 × 30 × 25 cm3 ). To mimic irradiation conditions during prostate treatments, we evaluated whether the presence of pelvic bones and calcifications affect ZnSe response. ZnSe detector design influence was also investigated. RESULTS: In contrast to low-Z organic and medium-Z inorganic scintillators, ZnSe and CsI media have substantially greater absorbed-dose energy dependence relative to water. The response was phantom-size dependent and changed by 11% between limited- and full-scatter conditions for ZnSe, but not for Al2 O3 . For a given phantom size, a part of the absorbed-dose energy dependence of ZnSe is caused not due to in-phantom scatter but due to source anisotropy. Thus, the absorbed-dose energy dependence of high-Z scintillators is a function of not only the radial distance but also the polar angle. Pelvic bones did not affect ZnSe response, whereas large and intermediate size calcifications reduced it by 9% and 5%, respectively, when placed midway between the source and the detector. CONCLUSIONS: Unlike currently prevalent low- and medium-Z scintillators, high-Z crystals are sensitive to characterization and in vivo measurement conditions. However, good agreement between MC data for ZnSe in the present study and experimental data for ZnSe:O by Jørgensen et al. (2021) suggests that detector signal is proportional to the average absorbed dose to the detector cavity. This enables an easy correction for non-TG43-like scenarios (e.g., patient sizes and calcifications) through MC simulations. Such information should be provided to the clinic by the detector vendors.


Subject(s)
Brachytherapy , In Vivo Dosimetry , Iridium Radioisotopes , Humans , Iridium Radioisotopes/therapeutic use , Monte Carlo Method , Radiometry , Scintillation Counting , Water
20.
Acta Oncol ; 61(6): 714-719, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35485446

ABSTRACT

BACKGROUND: Dosimetric and clinical comparison of two cohorts of Iridium-192 (Ir-192) and Cobalt-60 (Co-60) high-dose-rate brachytherapy (DR-BT) boost for localized prostate cancer. MATERIAL AND METHODS: Patients with localized prostate cancer receiving either Ir-192 or Co-60 high-dose-rate brachytherapy (HDR-BT) boost in combination with external beam radiotherapy (EBRT) in the period of 2002-2019 were evaluated for dosimetric differences, side effects, biochemical relapse-free survival (bRFS), metastasis-free survival (MFS), and overall survival (OS). EBRT, delivered in 46 Gy (DMean) in conventional fractionation, was followed by two fractions HDR-BT boost with 9 Gy (D90%) 2 and 4 weeks after EBRT. Genitourinary (GU)/gastrointestinal (GI) toxicity were evaluated utilizing the Common Toxicity Criteria for Adverse Events version 5.0 and biochemical failure was defined according to the Phoenix definition. RESULTS: A total of 338 patients with a median follow-up of 101.8 (IQR 65.7-143.0) months were evaluated. At 10 years the estimated bRFS, MFS, and OS in our patient sample were 81.1%/71.2% (p=.073), 87.0%/85.7% (p=.862), and 70.1%/69.7% (p=.998) for Ir-192/Co-60, respectively. Cumulative 5-year late grade ≥2 GU toxicity was 20% for Ir-192 and 18.3% for Co-60 (p=.771). Cumulative 5-year late grade ≥2 GI toxicity was 5.8% for Ir-192 and 4.6% for Co-60 (p=.610). Grade 3 late GU side effects were pronounced in the Ir-192 cohort with 8.1% versus 1.4% in the Co-60 cohort (p=.01), which was associated with significantly lower dose to the organs at risk in the Co-60 cohort. PTV D90% was 9.3 ± 0.8 Gy versus 9.0 ± 1.1 Gy (p=.027) for Ir-192 versus Co-60. PTV V100% and PTV V150% were not significantly different between both cohorts. CONCLUSION: Co-60 brachytherapy sources are an effective alternative to Ir-192 in combined prostate HDR-BT boost + EBRT.


Subject(s)
Brachytherapy , Prostatic Neoplasms , Brachytherapy/adverse effects , Cobalt Radioisotopes , Humans , Iridium Radioisotopes/therapeutic use , Male , Prostatic Neoplasms/drug therapy , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL