Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 14.974
Filter
1.
Ann Card Anaesth ; 27(1): 65-67, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38722125

ABSTRACT

ABSTRACT: One-lung ventilation is indicated during thoracic surgery for visualization and exposure of surgical site. It is achieved with bronchial blockers, double-lumen endobronchial tube, single-lumen endotracheal tubes and Univent tube for infants and children. Fibreoptic bronchoscope is required for placing and confirming the correct position of these tubes. We report a perioperative management of safe conduct of one lung ventilation for a 6-year child undergoing left lower lobe lobectomy through C-MAC video laryngoscope guided two single lumen tubes in limited resource settings where paediatric-sized fibreoptic bronchoscope is unavailable.


Subject(s)
Intubation, Intratracheal , One-Lung Ventilation , Humans , One-Lung Ventilation/methods , One-Lung Ventilation/instrumentation , Intubation, Intratracheal/methods , Intubation, Intratracheal/instrumentation , Child , Male , Bronchoscopy/methods , Fiber Optic Technology , Female , Laryngoscopy/methods
2.
BMC Anesthesiol ; 24(1): 181, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773386

ABSTRACT

BACKGROUND: Endotracheal intubation is challenging during cardiopulmonary resuscitation, and video laryngoscopy has showed benefits for this procedure. The aim of this study was to compare the effectiveness of various intubation approaches, including the bougie first, preloaded bougie, endotracheal tube (ETT) with stylet, and ETT without stylet, on first-attempt success using video laryngoscopy during chest compression. METHODS: This was a randomized crossover trial conducted in a general tertiary teaching hospital. We included anesthesia residents in postgraduate year one to three who passed the screening test. Each resident performed intubation with video laryngoscopy using the four approaches in a randomized sequence on an adult manikin during continuous chest compression. The primary outcome was the first-attempt success defined as starting ventilation within a one minute. RESULTS: A total of 260 endotracheal intubations conducted by 65 residents were randomized and analyzed with 65 procedures in each group. First-attempt success occurred in 64 (98.5%), 57 (87.7%), 56 (86.2%), and 46 (70.8%) intubations in the bougie-first, preloaded bougie, ETT with stylet, and ETT without stylet approaches, respectively. The bougie-first approach had a significantly higher possibility of first-attempt success than the preloaded bougie approach [risk ratio (RR) 8.00, 95% confidence interval (CI) 1.03 to 62.16, P = 0.047], the ETT with stylet approach (RR 9.00, 95% CI 1.17 to 69.02, P = 0.035), and the ETT without stylet approach (RR 19.00, 95% CI 2.62 to 137.79, P = 0.004) in the generalized estimating equation logistic model accounting for clustering of intubations operated by the same resident. In addition, the bougie first approach did not result in prolonged intubation or increased self-reported difficulty among the study participants. CONCLUSIONS: The bougie first approach with video laryngoscopy had the highest possibility of first-attempt success during chest compression. These results helped inform the intubation approach during CPR. However, further studies in an actual clinical environment are warranted to validate these findings. TRIAL REGISTRATION: Clinicaltrials.gov; identifier: NCT05689125; date: January 18, 2023.


Subject(s)
Cardiopulmonary Resuscitation , Cross-Over Studies , Intubation, Intratracheal , Laryngoscopy , Manikins , Video Recording , Intubation, Intratracheal/methods , Intubation, Intratracheal/instrumentation , Humans , Laryngoscopy/methods , Laryngoscopy/instrumentation , Cardiopulmonary Resuscitation/methods , Male , Female , Adult , Internship and Residency/methods , Video-Assisted Techniques and Procedures
3.
Acta Otorhinolaryngol Ital ; 44(Suppl. 1): S12-S19, 2024 May.
Article in English | MEDLINE | ID: mdl-38745512

ABSTRACT

Flexible endoscopic phonosurgery (FEPS) is one of the most recent and constantly evolving operative techniques in the field of minimally invasive laryngeal surgery. Thanks in part to the possibility of using new technologies, such as digital endoscopes, laser fibres, and different laryngeal injection materials, its fields of application have rapidly expanded. This narrative review describes the current possible indications of FEPS ranging from injection laryngoplasties in cases of vocal cord paralysis or mass defect, to the correction of dysphagia after open partial horizontal laryngectomies. Use of microscissors, microforceps, and laser fibres also allows this technique to be applied for removal of superficial vocal cord lesions, avoiding general anaesthesia in an increasing number of patients.


Subject(s)
Laryngeal Neoplasms , Postoperative Complications , Humans , Laryngeal Neoplasms/surgery , Postoperative Complications/etiology , Postoperative Complications/surgery , Laryngectomy/adverse effects , Laryngoscopy
4.
BMJ Case Rep ; 17(5)2024 May 06.
Article in English | MEDLINE | ID: mdl-38719265

ABSTRACT

A female infant born at 38 weeks and 2 days via induced vaginal delivery was admitted to the neonatal intensive care unit for respiratory distress soon after birth. Noted to have aphonia on examination, the patient underwent direct laryngoscopy and was diagnosed with an anterior glottic web and subglottic stenosis. The patient underwent a genetic workup including whole exome sequencing which resulted in a diagnosis of a FREM1-associated disorder. Congenital glottic webs and subglottic stenoses have not been previously described as clinical manifestations of FREM1-associated disorders.


Subject(s)
Aphonia , Laryngoscopy , Laryngostenosis , Respiratory Distress Syndrome, Newborn , Humans , Infant, Newborn , Female , Aphonia/genetics , Aphonia/diagnosis , Laryngostenosis/diagnosis , Laryngostenosis/genetics , Respiratory Distress Syndrome, Newborn/etiology , Respiratory Distress Syndrome, Newborn/diagnosis , Glottis
9.
J Vis Exp ; (205)2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38557448

ABSTRACT

Endotracheal intubation and subsequent ventilation are often basic requirements for translational research in rat models for various interventions that require controlled or high ventilation pressures or access to the thoracic cavity and organs. Conventional endoorotracheal intubation using the anatomically existing route through the mouth is well suited for survival experiments. However, this procedure poses some challenges, including generally higher levels of the required experience and technical skill, more advanced equipment, and greater time effort with relevant intubation failure rates and complications such as tracheal perforation, temporary systemic hypooxygenation, and relevant aerial leakage. This manuscript, therefore, presents a detailed step-by-step protocol for endotracheal intubation through tracheotomy in non-survival rat models when guaranteed intubation success, constant oxygenation levels, high ventilation pressures, or open thoracotomy are required. The protocol emphasizes the importance of meticulous surgical technique to ensure consistent and reliable outcomes, especially for researchers who are inexperienced or lack routine in the technique of endoorotracheal intubation via direct laryngoscopy. This procedure is, therefore, expected to minimize animal suffering and unnecessary animal losses.


Subject(s)
Thoracotomy , Tracheotomy , Animals , Rats , Intubation, Intratracheal/methods , Laryngoscopy/methods , Tracheostomy
10.
BMC Anesthesiol ; 24(1): 142, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38609865

ABSTRACT

BACKGROUND: The objective of this study was to evaluate a modern combined video laryngoscopy and flexible fiberoptic bronchoscope approach to placement of a double lumen endobronchial tube and further characterize potential strengths and weaknesses of this approach. METHODS: Retrospective chart review was conducted at our single institution, academic medical center, tertiary-care hospital. Patients aged 18 years of age or older were evaluated who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. No interventions were performed. RESULTS: Demographics and induction and intubation documentation were reviewed for 21 patients who underwent thoracic surgery and one-lung ventilation with placement of a double lumen endobronchial tube using a novel combined video laryngoscopy and flexible fiberoptic bronchoscope approach. First pass success using the combined approach was 86% (18/21). The five patients with an anticipated difficult airway had successful double lumen endobronchial tube placement on the first attempt. There were no instances of desaturation during double lumen endobronchial tube placement. No airway complications related to double lumen endobronchial tube placement were recorded. CONCLUSION: Use of a combined approach employing video laryngoscopy and a flexible fiberoptic bronchoscope may represent a reliable alternative approach to placement of double lumen endobronchial tubes.


Subject(s)
Laryngoscopes , One-Lung Ventilation , Humans , Adolescent , Adult , Aged , Retrospective Studies , Laryngoscopy , Intubation
12.
BMJ Case Rep ; 17(4)2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38575332

ABSTRACT

Missing and loose central incisors pose a great difficulty to anaesthesiologists during laryngoscopy and intubation. Left head rotation is a novel technique which facilitates intubation by improving the laryngoscopic view. We report the use of this technique in two patients with missing or loose central incisors to prevent dental trauma.


Subject(s)
Intubation, Intratracheal , Laryngoscopes , Humans , Intubation, Intratracheal/methods , Laryngoscopy/methods
13.
BMJ Case Rep ; 17(4)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38631815

ABSTRACT

Consensus-based recommendations are needed to better guide paediatric otolaryngologists in providing standardised care to children with sleep-disordered breathing (SDB). Here we present a unique case of vallecular cyst found during SDB workup in a patient in their middle childhood (6-12 years old). While the patient underwent successful cyst resection, he was noted to have a suspected recurrence 6 months later. Immediately prior to revision excision, repeat awake flexible fibre-optic laryngoscopy revealed complete resolution of the suspected recurrence. This case underscores the significance of performing a complete upper airway examination, including endoscopic examination, to identify structural and anatomical lesions in older children with SDB.


Subject(s)
Cysts , Laryngeal Diseases , Pharyngeal Diseases , Sleep Apnea Syndromes , Child , Humans , Adolescent , Pharyngeal Diseases/surgery , Laryngeal Diseases/surgery , Laryngoscopy , Cysts/surgery
14.
Vet Anaesth Analg ; 51(3): 266-270, 2024.
Article in English | MEDLINE | ID: mdl-38565449

ABSTRACT

OBJECTIVE: To develop and evaluate a low-cost three-dimensional (3D)-printed video laryngoscope (VLVET) for use with a commercial borescope. STUDY DESIGN: Instrument development and pilot study. ANIMALS: A total of six adult male Beagle dogs. METHODS: The VLVET consisted of a laryngoscope handle and a Miller-type blade, and a detachable camera holder that attached to various locations along the blade. The laryngoscope and camera holder were 3D-printed using black polylactic acid filament. Dogs were premedicated with intravenous (IV) medetomidine (15 µg kg-1) and anesthesia induced with IV alfaxalone (1.5 mg kg-1). The VLVET, combined with a borescope, was used for laryngeal visualization and intubation. Performance was evaluated by comparing direct and video-assisted views in sternal recumbency. The borescope camera was sequentially positioned at 2, 4, 6, 8 and 10 cm from the blade tip (distanceLARYNX-CAM), which was placed on the epiglottis during intubation or laryngoscopy. At the 10 cm distanceLARYNX-CAM, laryngeal visualization was sequentially scored at inter-incisor gaps of 10, 8, 6, 4 and 2 cm. Laryngeal visualization scores (0-3 range, with 0 = obstructed and 3 = unobstructed views) were statistically analyzed using the Friedman's test. RESULTS: Under direct visualization, the 2 cm distanceLARYNX-CAM had a significantly lower score compared with all other distanceLARYNX-CAM (all p = 0.014) because the view was obstructed by the camera holder and borescope camera. With both direct and camera-assisted views, visualization scores were higher at inter-incisor gaps ≥ 4 cm compared with 2 cm (all p < 0.05). CONCLUSIONS AND CLINICAL RELEVANCE: During laryngoscopy and intubation, the VLVET and borescope facilitated both direct and video laryngoscopy at distanceLARYNX-CAM in Beagle dogs when inter-incisor gaps were ≥ 4 cm.


Subject(s)
Intubation, Intratracheal , Laryngoscopes , Printing, Three-Dimensional , Animals , Dogs , Laryngoscopes/veterinary , Male , Intubation, Intratracheal/veterinary , Intubation, Intratracheal/instrumentation , Intubation, Intratracheal/methods , Video Recording , Laryngoscopy/veterinary , Laryngoscopy/methods , Laryngoscopy/instrumentation , Pilot Projects , Equipment Design
15.
BMC Anesthesiol ; 24(1): 157, 2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38658856

ABSTRACT

BACKGROUND: The main cause of anesthesia-related deaths is the failure to manage difficult airways. Difficult laryngoscopic exposure is a major cause of unsuccessful management of difficult airways. Inadequate preoperative airway assessment hinders the clinical management of difficult airways cases, emphasizing the critical need for accurate identification of difficult airways. Currently, no definitive and reliable indicators are available to predict a difficult airway. Our study aims to predict laryngoscope exposure risk factors by combining ultrasonically measured upper airway anatomic parameters with physical examination indicators. METHODS: Patients aged 18 to 75 years, classified as American Standards Association (ASA) I-III, and scheduled for elective general anesthesia with endotracheal intubation were included. All patients received the upper airway and ultrasonographic measurements. After anesthesia induction, laryngoscope exposure was analyzed using the Cormack-Lehane grading system, with Grades III and IV as indicative of difficult laryngoscopy. Univariate and multivariate logistic regression analyses were performed to identify reliable indicators for predicting difficult laryngoscopy. Receiver Operating Characteristic (ROC) curve analysis was utilized to assess the predictive performance of each indicator. RESULTS: A total of 1120 patients finished the study, with 710 cases found in Grade I laryngoscopic exposure group, 360 cases in Grade II group, and 50 cases in Grade III group. There was no case observed in Grade IV group, thereby resulting in an incidence of difficult laryngoscopy of 4.46%. Univariate logistic regression analysis revealed that several parameters including age, Body Mass Index (BMI), neck circumference, neck mobility, snoring intensity, as well as ultrasound measurements of the pre-epiglottic space and thyromental distance were identified as significant risk factors for difficult laryngoscopy (P < 0.05). Among these, BMI, and neck circumference exhibited notable predictive value, with Area Under The Curve (AUC) values of 0.746 (95%CI 0.649-0.842) and 0.732 (95%CI 0.638-0.827), respectively. Neck mobility was also identified as an independent risk factor for predicting difficult laryngoscopy (P = 0.009) in multivariate logistic regression analysis, with an AUC of 0.672 (0.562-0.782) in the ROC curve. CONCLUSIONS: Our findings revealed a direct correlation between difficult laryngoscopy and age, BMI, neck circumference, neck mobility, snoring intensity, as well as ultrasound measurements of the pre-epiglottic space and thyromental distance. Furthermore, neck mobility was identified as an independent predictive factor. TRIAL REGISTRATION: The trial was registered prior to patient enrollment at clinicaltrials.gov (register no. ChiCTR2100053826, Date of registration: November 30, 2021).


Subject(s)
Intubation, Intratracheal , Laryngoscopy , Ultrasonography , Humans , Laryngoscopy/methods , Middle Aged , Prospective Studies , Male , Female , Adult , Aged , Intubation, Intratracheal/methods , Ultrasonography/methods , Risk Factors , Young Adult , Anesthesia, General/methods , Adolescent , Body Mass Index
16.
Medicina (Kaunas) ; 60(4)2024 Apr 10.
Article in English | MEDLINE | ID: mdl-38674265

ABSTRACT

Background and Objectives: The ARNE score was developed for the prediction of a difficult airway for both general and ear, nose and throat (ENT) surgery with a universal cut-off value. We tested the accuracy of this score in the case of laryngeal surgery and provided an insight into its effects in combination with flexible laryngoscopy. Materials and Methods: This prospective pilot clinical study included 100 patients who were being scheduled for microscopic laryngeal surgery. We calculated the ARNE score for every patient, and flexible laryngoscopy was provided preoperative. Difficult intubation was assessed according to the intubation difficulty score (IDS). Results: A total of 33% patients had difficult intubation according to the IDS. The ARNE score showed limited accuracy for the prediction of difficult intubation in laryngology with p < 0.0001 and an AUC of 0.784. Flexible laryngoscopy also showed limitations when used as an independent parameter with p < 0.0001 and an AUC of 0.766. We defined a new cut-off value of 15.50 for laryngology, according to the AUC. After the patients were divided into two groups, according to the new cut-off value and provided cut-off value, the AUC improved to 0.707 from 0.619, respectively. Flexible laryngoscopy improved the prediction model of the ARNE score to an AUC of 0.882 and of the new cut-off value to an AUC of 0.833. Conclusions: It is recommended to use flexible laryngoscopy together with the ARNE score in difficult airway prediction in patients with laryngeal pathology. Also, the universally recommended cut-off value of 11 cannot be effectively used in laryngology, and a new cut-off value of 15.50 is recommended.


Subject(s)
Intubation, Intratracheal , Laryngoscopy , Humans , Laryngoscopy/methods , Male , Prospective Studies , Female , Middle Aged , Aged , Intubation, Intratracheal/methods , Pilot Projects , Adult , Airway Management/methods , Airway Management/standards , Laryngeal Diseases/surgery , Laryngeal Diseases/physiopathology , Larynx/pathology
17.
Head Neck ; 46(6): 1280-1293, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38562045

ABSTRACT

BACKGROUND: Although flexible laryngoscopy (FL) is the reference modality for diagnosing vocal cord paralysis (VCP), FL involves patient discomfort and insertion intolerance. Dynamic digital radiography (DDR) with high spatial and temporal resolution is easier to use and less invasive when evaluating VCP. METHODS: Seventy-eight patients underwent FL and DDR before and after neck surgery. Qualitative and quantitative vocal cord movement (VCM) evaluations were conducted. Patients with postoperative VCP were followed-up regularly. RESULTS: DDR exhibited diagnostic performance with 67% sensitivity and 100% specificity. The cutoff for VCM was 2.4 mm, with DDR exhibiting 100% sensitivity and 78% specificity. All cords with transient VCP had positive VCM at both 3 weeks and 2 months. Additionally, 50% and 75% of cords with permanent VCP had negative VCM at 3 weeks and 2 months, respectively. CONCLUSIONS: DDR is promising for the diagnosis of postoperative VCP and early prediction of permanent postoperative VCP.


Subject(s)
Laryngoscopy , Vocal Cord Paralysis , Humans , Vocal Cord Paralysis/diagnostic imaging , Vocal Cord Paralysis/etiology , Vocal Cord Paralysis/diagnosis , Male , Female , Middle Aged , Prospective Studies , Aged , Adult , Prognosis , Sensitivity and Specificity , Radiographic Image Enhancement/methods , Aged, 80 and over
SELECTION OF CITATIONS
SEARCH DETAIL
...