Molecules ; 25(4)2020 Feb 11.
Article in English | MEDLINE | ID: mdl-32054033

ABSTRACT

Stable organic free radicals are increasingly studied compounds due to the multiple and unusual properties imparted by the single electron(s). However, being paramagnetic, classical methods such as NMR spectroscopy can hardly be used due to relaxation and line broadening effects. EPR spectroscopy is thus better suited to get information about the immediate surroundings of the single electrons. EPR has enabled obtaining useful data in the context of host•guest chemistry, and a classical example is reported here for the stable (2,2,6,6-tetramethyl-4-oxo-piperidin-1-yl)oxyl or 4-oxo-TEMPO nitroxide (TEMPONE) inside the macrocycle host cucurbit[7]uril (CB[7]). Generally and also observed here, a contraction of the spectrum is observed as a result of the reduced nitrogen coupling constant due to inclusion complexation in the hydrophobic cavity of the host. Simulations of EPR spectra allowed determining the corresponding binding constant pointing to a weaker affinity for CB[7], compared to TEMPO with CB[7]. We complement this work by the results of EPR spectroscopy of a biradical: bis-TEMPO-bis-ketal (bTbk) with cucurbit[8]uril (CB[8]). Initial investigations pointed to very weak effects on the spectrum of the guest and incorrectly led us to conclude an absence of binding. However, simulations of EPR spectra combined with NMR data of reduced bTbk allowed showing inclusion complexation. EPR titrations were performed, and the corresponding binding constant was determined. 1H NMR spectra with reduced bTbk suggested a shuttle mechanism, at nearly one equivalent of CB[8], for which the host moves rapidly between two stations.


Subject(s)
Electron Spin Resonance Spectroscopy , Free Radicals/analysis , Macrocyclic Compounds/analysis , Electron Spin Resonance Spectroscopy/methods , Molecular Structure
2.
Anal Chim Acta ; 1046: 192-198, 2019 Jan 10.
Article in English | MEDLINE | ID: mdl-30482299

ABSTRACT

In this study, a field amplified sample injection (FASI) and hydrophobic interaction electrokinetic chromatography (HIEKC) method has been developed for the separation of five macrolide antibiotics: spiramycin, ivermectin, tylosin, josamycin, rapamycin, and one ansamycin drug - rifamycin. By the manipulation of both the sample and separation buffer compositions, their pH values and molarity, a systematic approach has been achieved to maximize analyte differential electrophoretic mobility and signal amplification. The impact of the sample solution composition and the injection mode on the signal amplification effect of the six tested antibiotics was also investigated. Moreover, the influence of the injection of the sample and the water plug on the quantity, symmetry and height of the analyte signal was demonstrated. All the analytes were completely resolved in less than 8 min in an uncoated fused-silica capillary of 75 µm internal diameter (I.D.) x 50 cm length. The electrophoretic separations were performed in a 60% (v/v) acetonitrile and 20 mM phosphate electrolyte system (pH 7.1) with an applied voltage of 25 kV. The established method was validated and confirmed to be applicable for the determination of the active ingredients in a quality control analysis.


Subject(s)
Anti-Bacterial Agents/analysis , Chromatography, Micellar Electrokinetic Capillary , Hydrophobic and Hydrophilic Interactions , Macrocyclic Compounds/analysis
3.
J Chromatogr A ; 1576: 42-50, 2018 Nov 16.
Article in English | MEDLINE | ID: mdl-30266236

ABSTRACT

In this work the simultaneous separation of chiral active pharmaceutical ingredients (API) in salt form from their counterions has been performed by using different high-efficiency macrocyclic glycopeptide-based chiral stationary phases (CSPs). Not only a new zwitterionic vancomycin-based CSP has been prepared (similarly to what was done for teicoplanin) but macrocyclic selectors have also been bonded to sub-2 µm fully porous silica particles through traditional ureidic linkage to obtain versions of CSPs suitable for ultra-high performance applications. The direct separation of chiral APIs and counterions is particularly attracting since it simplifies the workflow traditionally used with reduction of analysis time and costs. The wide selection of macrocyclic antibiotics CSPs now available has allowed to manage different cases that can happen in the simultaneous separation of APIs and their counterions (either cations or anions). Indeed, while inorganic cations are retained on traditional vancomycin- and teicoplanin-based CSPs, inorganic anions are almost unretained (due to Donnan's effect). On the other hand, cations and anions can be both retained on the zwitterionic versions of these CSPs. Afterwards, zwitterionic CSPs allowed the separation of other compounds including N-derivative amino-acids, profens, polyols, sugar anomers, oligosaccharides and inorganic anions/cations opening new perspectives in the use of this family of CSPs.


Subject(s)
Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/isolation & purification , Chemistry, Pharmaceutical/methods , Chromatography, High Pressure Liquid , Glycopeptides/chemistry , Macrocyclic Compounds/analysis , Macrocyclic Compounds/isolation & purification , Amino Acids/isolation & purification , Anions/chemistry , Anti-Bacterial Agents/chemistry , Macrocyclic Compounds/chemistry , Porosity , Silicon Dioxide/chemistry , Stereoisomerism
4.
Anal Chim Acta ; 987: 56-63, 2017 Sep 22.
Article in English | MEDLINE | ID: mdl-28916040

ABSTRACT

In this study, a matrix-assisted laser desorption/ionization (MALDI) mass spectrometry (MS) strategy using cucurbit[n]uril (CB[n]) as a host molecule is proposed for the analysis of low molecular weight (LMW) compounds in complex samples. As a proof-of-concept, CB[6] was selected as the host molecule, and endogenous polyamines in plant tissue were chosen as the target analytes. Due to the molecular recognition and mass shifting properties of CB[6], the ionic signals associated with polyamines were moved to the higher mass region (>1000 Da) after specifically binding to CB[6], while signal interference derived from the conventional organic matrix and the complex sample matrix remained in the low mass region because of the incompatibility of their molecular size with CB[6] cavities. The strategy not only facilitated the analysis of LMW compounds in complex samples by MALDI MS, but also offered high throughput by accomplishing the entire analytical procedure within 10 min. The detection of polyamine concentration showed good linearity in the range of 0.02-10.0 ng/µL with correlation coefficients (R) greater than 0.9915. The limits of detection were 8.8-28.8 pg. The good reproducibility and reliability of the method were demonstrated by excellent intraday and interday precisions with relative standard deviations less than 7.9%, and the recovery ranged from 92.1% to 117.1%. Finally, the good sensitivity of the method allowed for the quantitative analysis of endogenous polyamine concentrations in various micro-tissues of Arabidopsis thaliana (20.0-740.0 µg fresh weight for each sample).


Subject(s)
Arabidopsis/chemistry , Macrocyclic Compounds/analysis , Polyamines/analysis , Spectrometry, Mass, Matrix-Assisted Laser Desorption-Ionization , Reproducibility of Results
5.
Article in English | MEDLINE | ID: mdl-28365413

ABSTRACT

An ultra-performance liquid chromatography with triple quadrupole mass spectrometry method was developed and validated for the determination of direct acting antiviral drug concentrations in human liver fine needle aspirates. Liver fine needle aspirate (FNA) biopsy samples were homogenized in acetonitrile to stabilize the analytes and precipitate protein. The acetonitrile supernatants were diluted with internal standards and mobile phase. Separation was achieved with a Waters Acquity BEH C18 column (50×2.1mm, 1.7um) with a gradient elution of 0.1% formic acid in water and acetonitrile. The total run time was 4.25min. Detection of analytes was achieved using electrospray ionization (positive mode) and triple quadrupole selected reaction monitoring. Standard curve concentrations ranged from 12.5 to 5000ng/mL for dasabuvir and the m1 metabolite of dasabuvir, 1.25 to 2500ng/mL for ombitasvir and ritonavir, and 5.00 to 5000ng/mL for paritaprevir. The intra- and inter-day accuracy and precision were less than 13.7% in low, medium, and high quality control samples. The validated method was applied to the analysis of a liver fine needle aspirate of a patient undergoing direct acting antiviral therapy for hepatitis C virus.


Subject(s)
Anilides/analysis , Antiviral Agents/analysis , Carbamates/analysis , Chromatography, High Pressure Liquid/methods , Liver/chemistry , Macrocyclic Compounds/analysis , Sulfonamides/analysis , Tandem Mass Spectrometry/methods , Uracil/analogs & derivatives , 2-Naphthylamine , Animals , Cyclopropanes , Humans , Lactams, Macrocyclic , Limit of Detection , Needles , Proline/analogs & derivatives , Reproducibility of Results , Uracil/analysis , Valine
6.
J Mass Spectrom ; 52(2): 94-108, 2017 02.
Article in English | MEDLINE | ID: mdl-28061011

ABSTRACT

This paper presents a multi-residue method for direct enantioselective separation of chiral pharmacologically active compounds in environmental matrices. The method is based on chiral liquid chromatography and tandem mass spectrometry detection. Simultaneous chiral discrimination was achieved with a macrocyclic glycopeptide-based column with antibiotic teicoplanin as a chiral selector working under reverse phase mode. For the first time, enantioresolution was reported for metabolites of ibuprofen: carboxyibuprofen and 2-hydroxyibuprofen with this chiral stationary phase. Moreover, enantiomers of chloramphenicol, ibuprofen, ifosfamide, indoprofen, ketoprofen, naproxen and praziquantel were also resolved. The overall performance of the method was satisfactory in terms of linearity, precision, accuracy and limits of detection. The method was successfully applied for monitoring of pharmacologically active compounds at enantiomeric level in influent and effluent wastewater and in river water. In addition, the chiral recognition and analytical performance of the teicoplanin-based column was critically compared with that of the α1 -acid glycoprotein chiral stationary phase. Copyright © 2017 John Wiley & Sons, Ltd.


Subject(s)
Anti-Bacterial Agents/chemistry , Pharmaceutical Preparations/analysis , Phenylpropionates/analysis , Teicoplanin/chemistry , Water Pollutants, Chemical/analysis , Chromatography, Reverse-Phase , Ibuprofen/analysis , Macrocyclic Compounds/analysis , Rivers/chemistry , Solid Phase Extraction , Stereoisomerism , Tandem Mass Spectrometry , Wastewater/analysis
7.
Bioanalysis ; 8(13): 1353-63, 2016 Jul.
Article in English | MEDLINE | ID: mdl-27277877

ABSTRACT

AIM: Determination of paritaprevir and ritonavir in rat liver tissue samples. RESULTS: We successfully validated a UPLC-MS/MS method to measure paritaprevir and ritonavir in rat liver using deuterated internal standards (d8-paritapervir and d6-ritonavir). The method is linear from 20 to 20,000 and 5 to 10,000 pg on column for paritaprevir and ritonavir, respectively, and is normalized per milligram tissue. Interday and intraday variability ranged from 0.591 to 5.33% and accuracy ranged from -6.68 to 10.1% for quality control samples. The method was then applied to the measurement of paritaprevir and ritonavir in rat liver tissue samples from a pilot study. CONCLUSION: The validated method is suitable for measurement of paritaprevir and ritonavir within rat liver tissue samples for PK studies.


Subject(s)
Antiviral Agents/pharmacokinetics , Liver/metabolism , Macrocyclic Compounds/pharmacokinetics , Protease Inhibitors/pharmacokinetics , Ritonavir/pharmacokinetics , Tandem Mass Spectrometry/methods , Animals , Antiviral Agents/analysis , Chromatography, High Pressure Liquid/methods , Cyclopropanes , Hepacivirus/drug effects , Hepacivirus/enzymology , Hepatitis C/drug therapy , Lactams, Macrocyclic , Limit of Detection , Macrocyclic Compounds/analysis , Male , Pilot Projects , Proline/analogs & derivatives , Protease Inhibitors/analysis , Rats , Rats, Sprague-Dawley , Ritonavir/analysis , Sulfonamides
8.
Biomed Chromatogr ; 30(11): 1835-1842, 2016 Nov.
Article in English | MEDLINE | ID: mdl-27187504

ABSTRACT

Lepimectin, as an emulsifiable concentrate, was sprayed on shallots at the recommended dose rate (10 mL/20 L) to determine its residue levels, dissipation pattern, pre-harvest residue limits (PHRLs), and health risk. Samples were randomly collected over 10 days, extracted with acetonitrile, purified using an amino solid-phase extraction (NH2 -SPE) cartridge and analyzed using a high-performance liquid chromatography-photodiode array detection method. Field-incurred samples were confirmed using ultra-performance liquid chromatography-tandem mass spectrometry. The linearity was excellent, with a determination coefficient (R2 ) of ≥0.9991. The recoveries at two spiking levels (0.2 and 1.0 mg/kg) ranged from 84.49 to 87.64% with relative standard deviations of ≤7.04%. The developed method was applied to field samples grown in separate greenhouses, one located in Naju and one in Muan, in the Republic of Korea. The dissipation pattern was described by first-order kinetics with half-lives of 1.9 (Naju) and 1.7 days (Muan). The PHRL curves indicated that, if the lepimectin residues are <0.18 (Naju) and <0.13 mg/kg (Muan) 5 days before harvest, the residue levels will be lower than the maximum residue limit (0.05 mg/kg) upon harvesting. The risk assessment data indicated that lepimectin is safe for use in the cultivation of shallots, with no risk of detrimental effects to the consumer.


Subject(s)
Chromatography, High Pressure Liquid/methods , Food Additives/analysis , Lactones/analysis , Macrocyclic Compounds/analysis , Pesticide Residues/analysis , Shallots/chemistry , Tandem Mass Spectrometry/methods , Food Analysis/methods , Limit of Detection
9.
Ecotoxicol Environ Saf ; 111: 248-55, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25450941

ABSTRACT

This paper reported the occurrence and concentrations of macrocyclic-, polycyclic- and nitro musks in cosmetics and household commodities collected from Japan. The high concentrations and detection frequencies of Musk T, habanolide, and exaltolides were found in commercial products, suggesting their large amounts of production and usage in Japan. Polycyclic musks, HHCB and OTNE, also showed high concentrations in cosmetics and products. The estimated dairy intakes of Musk T and HHCB by the dermal exposure to commercial products were 7.8 and 7.9 µg/kg/day in human, respectively, and perfume and body lotion are dominant exposure sources. We also analyzed synthetic musks in house dusts. Polycyclic musks, HHCB and OTNE, showed high concentrations in samples, but macrocyclic musks were detected only in a few samples, although these types of musks were highly detected in commercial products. This is probably due to easy-degradation of macrocyclic musks in indoor environment. The dairy intakes of HHCB by dust ingestions were 0.22 ng/kg/day in human, which were approximately five orders of magnitudes lower than those of dermal absorption from commercial household commodities.


Subject(s)
Air Pollution, Indoor/analysis , Cosmetics/chemistry , Dust/analysis , Environmental Exposure/analysis , Ethers, Cyclic/analysis , Fatty Acids, Monounsaturated/analysis , Polycyclic Aromatic Hydrocarbons/analysis , Ethers, Cyclic/pharmacokinetics , Fatty Acids, Monounsaturated/pharmacokinetics , Humans , Japan , Macrocyclic Compounds/analysis , Macrocyclic Compounds/pharmacokinetics , Nitro Compounds/analysis , Nitro Compounds/pharmacokinetics , Perfume/chemistry , Polycyclic Aromatic Hydrocarbons/pharmacokinetics , Polycyclic Compounds/analysis , Polycyclic Compounds/pharmacokinetics , Skin Absorption
10.
J Chromatogr A ; 1364: 1-11, 2014 Oct 17.
Article in English | MEDLINE | ID: mdl-25240651

ABSTRACT

An on-line coupling solid-phase extraction (SPE) has been developed for the first time to preconcentrate trace amounts of 17 musk fragrances extensively used in personal care products (6 polycyclic musks, 3 nitro musks, 7 macrocyclic musks and 1 polycyclic musk degradation product) from wastewater samples, prior to analysis by gas chromatography and mass spectrometry through an on-column interface. A 10 mm × 2 mm I.D. precolumn packed with Oasis HLB (60 µm) or C18 (60 µm) was compared for the optimization of the solid-phase extraction process. The parameters affecting the transfer of the analytes from the precolumn to the GC system (e.g. flow-rate, temperature and solvent vapor exit time) as well as SPE parameters (e.g. sample flow, sample volume, elution solvent, etc.) were optimized. An organic modifier such as methanol was added to the sample before the extraction process to avoid adsorption problems. The use of the MS detector under selected ion monitoring acquisition enabled the analytes to be quantified at low ng L(-1) levels, preconcentrating only 10 mL of sample, and the limits of detection were between 1 and 30 ng L(-1). The method was applied for the determination of musk fragrances in wastewater samples from three urban wastewater treatment plants (WWTPs). The analysis of influent urban wastewater revealed that galaxolide, tonalide and ambrettolide were the most abundant musk compounds with concentrations ranging between 18 ng L(-1) and 45,091 ng L(-1), 852 ng L(-1) and 49,904 ng L(-1) and 507 ng L(-1) and 21,528 ng L(-1) respectively. The remaining musks were present at lower concentrations and two of the macrocyclic musk studied (musk MC4 and civetone) were not detected. The analysis of effluent wastewater showed a decrease in the concentrations of all of the compounds present in influent samples, with the decrease being more significantly in the case of polycyclic and nitro musks than for macrocyclic musks. Only HHCB-lactone remained constant or increased its concentration.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Perfume/analysis , Solid Phase Extraction , Wastewater/chemistry , Water Pollutants, Chemical/analysis , Adsorption , Macrocyclic Compounds/analysis , Nitro Compounds/analysis , Polycyclic Compounds/analysis
11.
J Chromatogr A ; 1314: 38-43, 2013 Nov 01.
Article in English | MEDLINE | ID: mdl-24060094

ABSTRACT

For the first time, headspace solid-phase microextraction (HS-SPME) has shown to be a powerful technique to extract macrocyclic musk fragrances directly from sewage sludge. It avoids the need to use additional extraction/preconcentration techniques or clean-up procedure and facilitates the automation of the method. Thus, a simple and fully automated method based on HS-SPME and GC-MS has been developed which allows the determination of eight macrocyclic musk fragrances at ngg(-1) (d.w.) levels. The optimal HS-SPME conditions were achieved when a PDMS/DVB 65µm fibre was exposed for 45min in the headspace of 0.25g sewage sludge samples mixed with 0.5mL of water stirred at 750rpm at 80°C. Optimal desorption conditions were found to be 250°C for 3min. Method detection limits were found in the low pgg(-1) range between 10pgg(-1) (d.w.) and 25pgg(-1) (d.w.) depending on the target analytes. In addition, under optimized conditions, the method gave good levels of intra-day and inter-day repeatabilities in sewage sludge with relative standard deviations varying between 1% to 9% and 6% to 15% respectively (n=5, 1000pgg(-1) d.w.). The applicability of the method was tested with sewage sludge from three urban sewage treatment plants (STPs). The analysis revealed the presence of the macrocyclic musks studied in several samples, with concentrations ranging between below MQL (method quantification limit) and 0.89ngg(-1) (d.w.).


Subject(s)
Automation , Gas Chromatography-Mass Spectrometry/methods , Macrocyclic Compounds/analysis , Odorants , Sewage/chemistry , Solid Phase Microextraction/methods , Limit of Detection
12.
Article in English | MEDLINE | ID: mdl-23566301

ABSTRACT

A confirmatory high-performance liquid chromatography method with fluorescence detection (HPLC-FLD) was developed and validated for the simultaneous determination of the following anti-parasitic veterinary drugs in foodstuffs (liver, muscle and milk) and feed: abamectin, doramectin, emamectin, eprinomectin, ivermectin and moxidectin. Samples were extracted, purified and analysed by HPLC-FLD after prior derivatisation of analytes with N-methylimidazole, trifluoracetic anhydride and acetic acid to produce stable fluorescent derivatives. Recoveries were in the range of 73-98% (liver), 82-93% (muscle), 77-84% (milk), and 93-110% (feed). In all matrices the coefficients of variation for repeatability and intra-laboratory reproducibility were satisfactory. For emamectin in liver the worst method performance was observed. As this multi-analyte method fully met the required criteria and applicability both to food and feed, it has been successfully applied in National Control Plans in food and feed.


Subject(s)
Lactones/analysis , Macrocyclic Compounds/analysis , Chromatography, High Pressure Liquid , Reference Standards , Reproducibility of Results , Spectrometry, Fluorescence
13.
Methods Mol Biol ; 970: 1-27, 2013.
Article in English | MEDLINE | ID: mdl-23283768

ABSTRACT

Chiral recognition phenomena play an important role in nature as well as analytical separation sciences. In separation sciences such as chromatography and capillary electrophoresis, enantiospecific interactions between the enantiomers of an analyte and the chiral selector are required in order to observe enantioseparations. Due to the large structural variety of chiral selectors applied, different mechanisms and structural features contribute to the chiral recognition process. This chapter briefly illustrates the current models of the enantiospecific recognition on the structural basics of various chiral selectors.


Subject(s)
Chromatography/methods , Electrophoresis, Capillary/methods , Aptamers, Nucleotide/analysis , Aptamers, Nucleotide/chemistry , Calixarenes/analysis , Calixarenes/chemistry , Crown Ethers/analysis , Crown Ethers/chemistry , Cyclodextrins/analysis , Cyclodextrins/chemistry , Ion Exchange , Macrocyclic Compounds/analysis , Macrocyclic Compounds/chemistry , Micelles , Models, Theoretical , Polymers/analysis , Polymers/chemical synthesis , Polysaccharides/analysis , Polysaccharides/chemistry , Protein Conformation , Proteins/analysis , Proteins/chemistry , Serum Albumin/analysis , Serum Albumin/chemistry , Stereoisomerism
14.
J Chromatogr A ; 1264: 87-94, 2012 Nov 16.
Article in English | MEDLINE | ID: mdl-23062975

ABSTRACT

A fully automated method has been developed for the determination of eight macrocyclic musk fragrances in urban wastewater. The procedure includes the enrichment of the analytes by microextraction by packed sorbent (MEPS) followed by large volume injection-gas chromatography-mass spectrometry (LVI-GC-MS). The main factors in the MEPS technique were optimized. For all of the analytes, the highest enrichment factors were achieved when 4 mL samples were extracted by using C18 MEPS-sorbent and 50 µL of ethyl acetate were used for desorption. The eluate was directly analysed by GC-MS. Detection limits were found to be between 5 ng L(-1) and 10 ng L(-1), depending on the target analytes. In addition, under optimized conditions, the method gave good levels of intra-day and inter-day repeatability in wastewater samples with relative standard deviation (RSD) (n=3, 1,000 ng L(-1)) less than 5% and 9%, respectively. The applicability of the method was tested with wastewater samples from two influent and effluent urban wastewater treatment plants (WWTPs). The analysis of influent urban wastewater revealed the presence of most of the macrocylic musks at concentrations higher than the method quantification limits (MQLs), being the most abundant analyte ambrettolide at 9.29 µg L(-1). In addition, the analyses of effluent urban wastewater showed a decrease in the concentrations with macrocyclic musk concentrations of between not detected (n.d.) and 2.26 µg L(-1) being detected.


Subject(s)
Automation , Fatty Acids, Monounsaturated , Gas Chromatography-Mass Spectrometry/methods , Macrocyclic Compounds/analysis , Solid Phase Microextraction/methods , Reproducibility of Results
15.
Int J Mol Sci ; 13(4): 4982-4992, 2012.
Article in English | MEDLINE | ID: mdl-22606024

ABSTRACT

A novel family of tetraaza macrocyclic Cu(II) complexes [CuLX(2)] (where L = N(4) donor macrocyclic ligands) and (X = Cl(-), NO(3) (-)) have been synthesized and characterized by elemental analysis, magnetic moments, IR, EPR, mass, electronic spectra and thermal studies. The magnetic moments and electronic spectral studies suggest square planar geometry for [Cu(DBACDT)]Cl(2) and [Cu(DBACDT)](NO(3))(2) complexes and distorted octahedral geometry to the rest of the ten complexes. The biological activity of all these complexes against gram-positive and gram-negative bacteria was compared with the activity of existing commercial antibacterial compounds like Linezolid and Cefaclor. Six complexes out of twelve were found to be most potent against both gram-positive as well as gram-negative bacteria due to the presence of thio group in the coordinated ligands.


Subject(s)
Anti-Bacterial Agents/pharmacology , Aza Compounds/pharmacology , Gram-Negative Bacteria/drug effects , Gram-Positive Bacteria/drug effects , Macrocyclic Compounds/pharmacology , Acetamides/pharmacology , Anti-Bacterial Agents/analysis , Anti-Bacterial Agents/chemistry , Aza Compounds/analysis , Aza Compounds/chemistry , Cefaclor/pharmacology , Copper/chemistry , Linezolid , Macrocyclic Compounds/analysis , Macrocyclic Compounds/chemistry , Magnetic Resonance Spectroscopy , Microbial Sensitivity Tests , Oxazolidinones/pharmacology , Spectrophotometry, Infrared
16.
J Org Chem ; 77(10): 4679-87, 2012 May 18.
Article in English | MEDLINE | ID: mdl-22524459

ABSTRACT

The aggregation of macrocyclic oligocholates with introverted hydrophilic groups and aromatic side chains was studied by fluorescence spectroscopy and liposome leakage assays. Comparison between the solution and the membrane phase afforded insight into the solvophobically driven aggregation. The macrocycles stacked over one another in lipid membranes to form transmembrane nanopores, driven by a strong tendency of the water molecules in the interior of the amphiphilic macrocycles to aggregate in a nonpolar environment. The aromatic side chains provided spectroscopic signatures for stacking, as well as additional driving force for the aggregation. Smaller, more rigid macrocycles stacked better than larger, more flexible ones because the cholate building blocks in the latter could rotate outward and diminish the conformation needed for the water-templated hydrophobic stacking. The acceptor-acceptor interactions among naphthalenediimide (NDI) groups were more effective than the pyrene-NDI donor-acceptor interactions in promoting the transmembrane pore formation of the oligocholate macrocycles.


Subject(s)
Cell Membrane/chemistry , Cholates/analysis , Cholates/chemistry , Imides/chemistry , Lipid Bilayers/chemistry , Macrocyclic Compounds/analysis , Macrocyclic Compounds/chemistry , Naphthalenes/chemistry , Pyrenes/chemistry , Solutions/chemistry , Unilamellar Liposomes/chemistry , Water/chemistry , Hydrophobic and Hydrophilic Interactions , Lipid Bilayers/analysis , Lipid Bilayers/metabolism , Macrocyclic Compounds/metabolism , Magnetic Resonance Spectroscopy , Models, Molecular , Nanopores , Solutions/analysis , Spectrometry, Fluorescence , Unilamellar Liposomes/metabolism , Water/analysis
17.
Anal Chim Acta ; 705(1-2): 24-9, 2011 Oct 31.
Article in English | MEDLINE | ID: mdl-21962343

ABSTRACT

In this work a method is proposed and demonstrated for the analysis of the macrocyclic lactones abamectin, doramectin, eprinomectin, ivermectin and moxidectin in bovine milk by liquid chromatography coupled to mass spectrometry (LC-MS/MS) and liquid chromatography with fluorescence detection (LC-FL). The method is based on liquid-liquid extraction followed by a low temperature purification (LLE-LTP) step. Moreover, the proposed method was validated according to the Commission Decision 2002/657/EC, using LC-MS/MS and LC-FL for confirmatory and quantitative analysis, respectively. For LC-MS/MS the recovery rates observed ranged from 101.2 to 141.6% with coefficient of variation from 2.6 to 19.8%. For LC-FL the recovery rates observed ranged from 100.2 to 105% and coefficient of variations from 2.9 to 8.8%. Matrix effects were negligible due to the low temperature purification step. The quantification limits were far below the maximum limits established by regulations of all countries consulted. The proposed method proved to be simple, easy, and adequate for high-throughput analysis of a large number of samples per day at low cost.


Subject(s)
Lactones/analysis , Liquid-Liquid Extraction/methods , Macrocyclic Compounds/analysis , Milk/chemistry , Tandem Mass Spectrometry/methods , Animals , Cattle , Chromatography, Liquid/economics , Chromatography, Liquid/methods , Fluorescence , Lactones/chemistry , Lactones/isolation & purification , Liquid-Liquid Extraction/economics , Macrocyclic Compounds/chemistry , Macrocyclic Compounds/isolation & purification , Sensitivity and Specificity , Tandem Mass Spectrometry/economics
18.
Org Biomol Chem ; 9(22): 7647-51, 2011 Oct 26.
Article in English | MEDLINE | ID: mdl-21947031

ABSTRACT

The formamidoxime configurational Z isomer coupled with the pyridylbiscarboxamide conformational codon were used to fold planar, curved structures. When embedded into macrocycles, this folded motif promotes dimerization through π-π stacking and hydrogen-bonding and the formation of tubules akin to molecular channels in the solid state.


Subject(s)
Chemistry, Physical/methods , Macrocyclic Compounds/chemical synthesis , Oximes/chemical synthesis , Amides/chemistry , Crystallography, X-Ray , Dimerization , Hydrogen Bonding , Macrocyclic Compounds/analysis , Magnetic Resonance Spectroscopy , Models, Molecular , Molecular Conformation , Molecular Mimicry , Oximes/analysis , Pyridines/chemistry
19.
Chem Commun (Camb) ; 47(17): 4992-4, 2011 May 07.
Article in English | MEDLINE | ID: mdl-21431124

ABSTRACT

DOTASQ (for DOTA-templated Synthetic G-quartet) is the first prototype of nature-inspired G-quadruplex ligand: its design, founded on a possible intramolecular G-quartet formation, enables it to interact with G-quadruplex DNA via an unprecedented nature-mimicking binding mode, based on the association between two G-quartets, one being native (quadruplex) and the other one artificial (ligand).


Subject(s)
Antineoplastic Agents/metabolism , G-Quadruplexes , Guanine/metabolism , Macrocyclic Compounds/metabolism , Molecular Probes/metabolism , Antineoplastic Agents/analysis , Antineoplastic Agents/chemical synthesis , Binding Sites , Fourier Analysis , Humans , Hydrophobic and Hydrophilic Interactions , Ligands , Macrocyclic Compounds/analysis , Macrocyclic Compounds/chemical synthesis , Models, Molecular , Molecular Probes/analysis , Molecular Probes/chemical synthesis , Nucleic Acid Conformation , Terbium/metabolism
20.
J Am Chem Soc ; 131(45): 16395-7, 2009 Nov 18.
Article in English | MEDLINE | ID: mdl-19831351

ABSTRACT

Self-assembly of 1,3-di(4'-terpyridinyl)arenes by using the labile tpy-Cd(II)-tpy (where tpy = 2,2':6',2''-terpyridine) connectivity afforded access to hexacadmium macrocycles in high yield. These supramolecular assemblies were characterized by traveling wave ion mobility mass spectrometry (TWIM-MS).


Subject(s)
Cadmium/analysis , Macrocyclic Compounds/analysis , Organometallic Compounds/analysis , Molecular Structure , Spectrometry, Mass, Electrospray Ionization , Stereoisomerism
SELECTION OF CITATIONS
SEARCH DETAIL
...