Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.522
Filter
1.
Vestn Oftalmol ; 140(2): 34-39, 2024.
Article in Russian | MEDLINE | ID: mdl-38742496

ABSTRACT

PURPOSE: This study evaluates the accuracy of modern intraocular lens (IOL) calculation formulas using axial length (AL) data obtained by ultrasound biometry (UBM) compared to the third-generation SRK/T calculator. MATERIAL AND METHODS: The study included 230 patients (267 eyes) with severe lens opacities that prevented optical biometry, who underwent phacoemulsification (PE) with IOL implantation. IOL power calculation according to the SRK/T formula was based on AL and anterior chamber depth obtained by UBM (Tomey Biometer Al-100) and keratometry on the Topcon KR 8800 autorefractometer. To adapt AL for new generation calculators - Barrett Universal II (BUII), Hill RBF ver. 3.0 (RBF), Kane and Ladas Super Formula (LSF) - the retinal thickness (0.20 mm) was added to the axial length determined by UBM, and then the optical power of the artificial lens was calculated. The mean error and its modulus value were used as criteria for the accuracy of IOL calculation. RESULTS: A significant difference (p=0.008) in the mean IOL calculation error was found between the formulas. Pairwise analysis revealed differences between SRK/T (-0.32±0.58 D) and other formulas - BUII (-0.16±0.52 D; p=0.014), RBF (-0.17±0.51 D; p=0.024), Kane (-0.17±0.52 D; p=0.029), but not with the LSF calculator (-0.19±0.53 D; p=0.071). No significant differences between the formulas were found in terms of mean error modulus (p=0.238). New generation calculators showed a more frequent success in hitting target refraction (within ±1.00 D in more than 95% of cases) than the SRK/T formula (86%). CONCLUSION: The proposed method of adding 0.20 mm to the AL determined by UBM allows using this parameter in modern IOL calculation formulas and improving the refractive results of PE, especially in eyes with non-standard anterior segment structure.


Subject(s)
Biometry , Lenses, Intraocular , Phacoemulsification , Refraction, Ocular , Humans , Biometry/methods , Male , Female , Aged , Middle Aged , Reproducibility of Results , Refraction, Ocular/physiology , Phacoemulsification/methods , Axial Length, Eye/diagnostic imaging , Lens Implantation, Intraocular/methods , Cataract/physiopathology , Cataract/diagnosis , Optics and Photonics/methods , Microscopy, Acoustic/methods
2.
J AAPOS ; 28(2): 103863, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38458600

ABSTRACT

PURPOSE: To investigate the correlation between swept-source anterior segment optical coherence tomography (AS-OCT) and ultrasound biomicroscopy (UBM) in congenital corneal opacity (CCO). METHODS: All children with unilateral or bilateral congenital corneal opacities who underwent examination under anesthesia (EUA) and anterior segment optical coherence tomography (AS-OCT) imaging from January 1, 2022, to December 31, 2022, were included. Main outcome measures were corneal and anterior segment evaluation and correlation of UBM and AS-OCT findings. RESULTS: A total of 22 eyes of 15 patients were imaged using both technologies. The age at first EUA ranged from 11 days to 4 years. Different phenotypes were classified based on the clinical examination, UBM, and AS-OCT findings. Fourteen eyes were diagnosed with Peters anomaly, congenital corneal staphyloma was observed in 4 eyes, 2 eyes had coloboma, 1 eye had peripheral sclerocornea, and 1 eye was diagnosed with congenital primary aphakia. AS-OCT and UBM findings were closely correlated in 18 of 22 eyes (82%) but AS-OCT failed to provide detailed information in 4 eyes (18%) where UBM revealed more details. CONCLUSIONS: Although AS-OCT offers valuable preliminary data for initial assessment and counseling, it may not consistently provide precise assessments in all cases. Therefore, UBM should be considered for definitive evaluation.


Subject(s)
Corneal Opacity , Microscopy, Acoustic , Child , Humans , Infant, Newborn , Microscopy, Acoustic/methods , Tomography, Optical Coherence/methods , Corneal Opacity/diagnostic imaging , Anterior Eye Segment/diagnostic imaging , Cornea/diagnostic imaging
3.
J Refract Surg ; 40(3): e142-e147, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38466767

ABSTRACT

PURPOSE: To evaluate the accuracy of the Reinstein formula with hand-held ultrasound biomicroscopy (UBM) measurements for sizing of the Implantable Collamer Lens (ICL). METHODS: A total of 107 myopic eyes of 57 patients implanted with the ICL were included in the study. The size of the ICL was selected based on the manufacturer's recommendations. Agreement between the vault predicted by the Reinstein formula and the vault measured postoperatively was analyzed with Bland-Altman plots. RESULTS: A total of 95% and 81% of patients had a postoperative vault ranging from 150 to 1,000 and 250 to 750 µm, respectively. The mean vault predicted by the Reinstein formula and the postoperative vault in the current study were 580 ± 181 and 547 ± 200 µm, respectively. The size recommendations of the Reinstein formula and the formula provided by the manufacturer, the Kojima formula, and the Dougherty formula overlapped in 50%, 57%, and 49% of eyes, respectively. CONCLUSIONS: The results show that the Reinstein formula combined with a hand-held UBM provides reliable sizing predictions of the ICL. However, considering that robotic UBM measurements have demonstrated a narrower range of deviation in predicting vault depth in previous studies, a direct comparison study between robotic UBM and hand-held UBM measurements is necessary to fully assess the limitations of combining hand-held UBM with the Reinstein formula. [J Refract Surg. 2024;40(3):e142-e147.].


Subject(s)
Myopia , Phakic Intraocular Lenses , Humans , Microscopy, Acoustic/methods , Lens Implantation, Intraocular/methods , Visual Acuity , Myopia/surgery , Retrospective Studies
4.
Am J Vet Res ; 85(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38428156

ABSTRACT

OBJECTIVE: To assess the characteristics of blebs formed after Ahmed glaucoma valve (AGV) surgery in dogs using ultrasound biomicroscopy (UBM) and to analyze their correlation with postoperative intraocular pressure (IOP). ANIMALS: 16 eyes (13 dogs) were diagnosed with primary angle-closure glaucoma and were followed up after AGV surgery from June 2021 to September 2023. METHODS: In this prospective study, UBM examinations were performed to assess bleb characteristics, including bleb wall thickness and reflectivity. IOP at the time of UBM imaging and the duration from AGV surgery to UBM imaging were recorded. Histological examination of an enucleated eye removed due to uncontrolled IOP leading to blindness was also conducted. RESULTS: A significant correlation was observed between IOP and relative reflectivity (Pearson r = 0.60; P = .01), and a negative correlation was observed between bleb wall thickness and relative reflectivity (Pearson r = -0.72; P = .002). No significant correlation was observed between the duration from AGV surgery to UBM imaging and either bleb wall thickness or relative reflectivity, respectively. Histological examination of the enucleated eye revealed collagen-rich fibrous encapsulation of the bleb wall, including myofibroblasts that exhibited positive α-smooth muscle actin immunostaining. CLINICAL RELEVANCE: In dogs that underwent AGV surgery, less dense, thick-walled blebs on UBM tended to maintain IOP within the normal range. However, denser, thinner-walled blebs showed IOP levels above the normal range despite the use of antiglaucoma medications. UBM is a useful tool for evaluating bleb characteristics and their influence on IOP regulation after AGV surgery in dogs.


Subject(s)
Dog Diseases , Glaucoma Drainage Implants , Glaucoma, Angle-Closure , Intraocular Pressure , Microscopy, Acoustic , Animals , Dogs , Dog Diseases/surgery , Dog Diseases/diagnostic imaging , Microscopy, Acoustic/veterinary , Glaucoma, Angle-Closure/veterinary , Glaucoma, Angle-Closure/surgery , Female , Prospective Studies , Male , Glaucoma/veterinary , Glaucoma/surgery , Glaucoma/diagnostic imaging
5.
Am J Ophthalmol ; 262: 178-185, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38360335

ABSTRACT

PURPOSE: To investigate the correlation between the opening and closing states of anterior chamber angle (ACA) and the density of limbal epithelial basal cells (LEBCs) in subjects with primary angle-closure glaucoma (PACG). DESIGN: Cross-sectional observational study. METHODS: A total of 54 eyes of 29 patients diagnosed with PACG were included in the study. Fifty-four eyes from normal subjects were included as control. Automatic evaluation system for ultrasound biomicroscopy images of anterior chamber angle was used to assist ophthalmologists in identifying the opening or closing state of ACA, and the in vivo confocal microscopy (IVCM) was used to evaluate the density of LEBCs in different directions. RESULTS: (1) The average density of LEBCs in the superior, inferior, nasal, and temporal limbus of the eyes in the PACG group was lower than that in the control group, and this pattern did not align with the density distribution observed in the control group. (2) In the early, moderate and advanced PACG, the density of LEBCs corresponding to the closed angle was lower than that in the control group (P < .05). Compared with the density of LEBCs corresponding to the closed angle and the open angle, the closed angle of PACG in the early, moderate and advanced stages was less than that in the open angle (P < .05 in the early and moderate stages; advanced stage P > .05). (3) The basal cell density was processed by dimensionless analysis. In the data calculated by averaging and minimizing, both closed angle dimensionless values were smaller than the open angle (P < .05). (4) Comparative analysis was conducted among the normal, open-angle, and closed-angle conditions in the superior, inferior, nasal, and temporal limbus. In the early stage of PACG, significant differences were observed in 4 limbal regions (P < .05), while in the moderate PACG stage, this difference was noted in 3 limbal regions (P < .05). In advanced PACG, 2 limbal regions exhibited significant differences (P < .05). These findings suggest that during the early PACG stage, angle closure is the predominant influencing factor on LEBCs density, while in the advanced stage, the decrease in density is attributed to a combination of angle closure and the natural progression of the disease. CONCLUSIONS: There is a significant correlation between anterior chamber angle status and LEBCs. Advanced PACG and angle closure should be highly suspected of the occurrence of limbal stem cell deficiency (LSCD).


Subject(s)
Anterior Chamber , Glaucoma, Angle-Closure , Intraocular Pressure , Limbus Corneae , Microscopy, Acoustic , Microscopy, Confocal , Stem Cells , Humans , Glaucoma, Angle-Closure/diagnosis , Glaucoma, Angle-Closure/physiopathology , Cross-Sectional Studies , Limbus Corneae/pathology , Limbus Corneae/diagnostic imaging , Male , Female , Middle Aged , Anterior Chamber/diagnostic imaging , Anterior Chamber/pathology , Cell Count , Aged , Stem Cells/pathology , Intraocular Pressure/physiology , Gonioscopy , Limbal Stem Cell Deficiency
6.
Clin Exp Ophthalmol ; 52(2): 186-206, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38214059

ABSTRACT

Ultrasound biomicroscopy (UBM) is an invaluable investigation for imaging anterior segment structures. Although it is operator-dependent and time consuming, unlike optical-based imaging techniques, it is able to image structures posterior to the iris, such as the zonules, ciliary body and part of the pars plana. It is especially useful in advanced cataracts, traumatic cataracts, subluxed lenses, posterior polar cataracts, and congenital and developmental anomalies affecting the anterior segment. It provides diagnostic information in eyes with complex cataracts or intraocular lens (IOL)-related pathology, and aids in surgical planning in order to minimise complications. In this review, we describe the UBM features of various lenticular pathologies and demonstrate its application in the diagnosis and surgical management of lens and IOL-related pathologies.


Subject(s)
Cataract Extraction , Cataract , Lenses, Intraocular , Humans , Microscopy, Acoustic/methods , Lens Implantation, Intraocular/methods , Cataract/diagnosis , Cataract Extraction/methods
7.
BMC Ophthalmol ; 24(1): 34, 2024 Jan 23.
Article in English | MEDLINE | ID: mdl-38263030

ABSTRACT

BACKGROUND: The structural features have an impact on the surgical prognosis for congenital corneal opacity (CCO). The structural classification system of CCO, however, is lacking. Based on data from ultrasound biomicroscopy (UBM) findings in infants and toddlers with CCO, this research proposed a classification system for the anterior segment structure severity. METHODS: Medical records, preoperative UBM images and slit-lamp photographs of infants and toddlers diagnosed with CCO at University Third Hospital between December 2018 and June 2022 were reviewed. According to the anterior segment structural features observed in UBM images, eyes were classified as follows: U1, opaque cornea only; U2, central anterior synechia; U3, peripheral anterior synechia combined with angle closure; and U4, aniridia or lens anomaly. The opacity appearance and corneal vascularization density observed in slit-lamp photographs were assigned grades according to previous studies. The extent of vascularization was also recorded. The corresponding intraocular anomaly classifications and ocular surface lesion severity were analysed. RESULTS: Among 81 eyes (65 patients), 41 (50.6%) were right eyes, and 40 (49.4%) were left eyes. The median age at examination was 6.91 months (n = 81, 1.00, 34.00). Two (2.5%) of the 81 eyes were classified as U1, 20 (24.7%) as U2, 22 (27.2%) as U3a, 11 (13.6%) as U3b and 26 (32.1%) as U4. Bilateral CCO eyes had more severe UBM classifications (P = 0.019), more severe dysgenesis (P = 0.012) and a larger angle closure (P = 0.009). Eyes with more severe UBM classifications had higher opacity grades (P = 0.003) and vascularization grades (P = 0.014) and a larger vascularization extent (P = 0.001). Eyes with dysgenesis had higher haze grades (P = 0.012) and more severe vascularization (P = 0.003 for density; P = 0.008 for extent), while the angle closure range was related to haze grade (P = 0.013) and vascularization extent (P = 0.003). CONCLUSIONS: This classification method based on UBM and slit-lamp photography findings in the eyes of CCO infants and toddlers can truly reflect the degree of abnormality of the ocular surface and anterior segment and is correlated with the severity of ocular surface anomalies. This method might provide meaningful guidance for surgical procedure design and prognostic determinations for keratoplasty in CCO eyes.


Subject(s)
Corneal Diseases , Corneal Opacity , Eye Abnormalities , Iris Diseases , Infant , Humans , Child, Preschool , Microscopy, Acoustic , Slit Lamp Microscopy , Neovascularization, Pathologic , Cornea
8.
J Biomed Opt ; 29(Suppl 1): S11517, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38223679

ABSTRACT

Significance: Photoacoustic Doppler flowmetry offers quantitative blood perfusion information in addition to photoacoustic vascular contrast for rectal cancer assessment. Aim: We aim to develop and validate a correlational Doppler flowmetry utilizing an acoustic resolution photoacoustic microscopy (AR-PAM) system for blood perfusion analysis. Approach: To extract blood perfusion information, we implemented AR-PAM Doppler flowmetry consisting of signal filtering and conditioning, A-line correlation, and angle compensation. We developed flow phantoms and contrast agent to systemically investigate the flowmetry's efficacy in a series of phantom studies. The developed correlational Doppler flowmetry was applied to images collected during in vivo AR-PAM for post-treatment rectal cancer evaluation. Results: The linearity and accuracy of the Doppler flow measurement system were validated in phantom studies. Imaging rectal cancer patients treated with chemoradiation demonstrated the feasibility of using correlational Doppler flowmetry to assess treatment response and distinguish residual cancer from cancer-free tumor bed tissue and normal rectal tissue. Conclusions: A new correlational Doppler flowmetry was developed and validated through systematic phantom evaluations. The results of its application to in vivo patients suggest it could be a useful addition to photoacoustic endoscopy for post-treatment rectal cancer assessment.


Subject(s)
Photoacoustic Techniques , Rectal Neoplasms , Humans , Laser-Doppler Flowmetry/methods , Rheology/methods , Microscopy, Acoustic/methods , Acoustics , Rectal Neoplasms/diagnostic imaging , Photoacoustic Techniques/methods
9.
Med Phys ; 51(4): 3124-3129, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38055556

ABSTRACT

BACKGROUND: Ocular foreign bodies (OFBs) are a relatively common occurrence in ocular injuries, and a severe risk factor for vision disorders. They are notoriously challenging to identify and localize precisely to allow surgical removal, even with the most recent technological advancements. PURPOSE: To compare the efficiency of different imaging methods in detecting and localizing OFBs. METHODS: We conducted a retrospective analysis of the medical records of patients with OFBs, detected by ultrasound biomicroscopy (UBM) and confirmed during surgery. Patients who presented to our medical center between January 2016 and January 2022 and also underwent computed tomography (CT), X ray, and/or ocular B-scan ultrasonography (B-scans) were selected. RESULTS: This study included 134 patients with a history of ocular trauma and OFBs (mean age: 47.25 years, range: 8-78). The mean time interval from injury to UBM examination was 36.31 months (range: 0.2-120 months). Most OFBs were metallic (51.82%) or plant-based (25.37%); 22.39% of them were located in the sclera, 26.87% in the anterior chamber, and 23.88% in the ciliary body and iris. OFBs ranged in size from 0.10 to 6.67 mm (mean: 1.15 ± 1.10 mm). B-scans identified OFBs in 37 of the 119 patients examined (31.09%); CT in 52 of 84 patients (61.90%); and radiography in 29 of 50 patients (58.00%). Univariate and multivariate analyses determined that both CT and radiography showed low detection rates for plant-based versus non-plant-based OFBs (CT: p < 0.001; radiography: p = 0.007), small particles (<1.00 mm vs. >1.00 mm; CT: p = 0.001, radiography: p = 0.024), and with eyeball wall locations (vs. intraocular; CT: p < 0.001, radiography: p = 0.021). Similarly, B-scans were less efficient for plant-based and eyeball wall-located OFBs (both p = 0.001), whereas the difference based on dimensions was not significant (p = 0.118). CONCLUSIONS: CT, radiography, and B-scans showed lower detection rates for plant-based, small, and eyeball wall-located OFBs. Our findings strongly suggest that UBM could be a more adequate imaging modality when such OFBs are suspected.


Subject(s)
Eye Foreign Bodies , Humans , Middle Aged , Retrospective Studies , Eye Foreign Bodies/diagnostic imaging , Eye Foreign Bodies/etiology , Eye Foreign Bodies/surgery , Microscopy, Acoustic , Ultrasonography , Radiography
10.
J Med Ultrason (2001) ; 51(1): 29-37, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37971564

ABSTRACT

PURPOSE: Microglia, the brain's immune cells, play important roles in neuronal differentiation, survival, and death. The function of microglia is deeply related to the morphologies; however, it is too complex to observe conventionally and identify the condition of living microglia using optical microscopes. Herein, we proposed a new method to observe living cultured microglia and their reactivity to inflammation via the acoustic impedance mode of a scanning acoustic microscope. METHODS: Primary cultured microglia collected from rat pups exposed to acetamiprid, an insecticide, in utero were observed with both acoustic interface impedance mode (C-mode) and transparent three-dimensional impedance mode (B-mode). RESULTS: We characterized microglia into four types based on the results obtained from acoustic impedance, cytoskeletal information, and laser confocal imaging. Biphasic acoustic observation using B-mode and C-mode gave us information regarding the dynamic morphologies of living microglia treated with adenosine triphosphate (ATP) (600 µmol/L), which reflects distress signals from inflamed neurons. Acetamiprid exposure induced microglia response even in the neonatal period. ATP stimulus altered the shape and thickness of microglia with a change in the bulk modulus of the cell. Three-dimensional alteration with ATP stimulus could be observed only after biphasic acoustic observation using B-mode and C-mode. This acoustic observation was consistent with confocal observation using anti-Iba-1 and P2Y12 immunocytochemistry. CONCLUSION: This study demonstrated the adequacy of using a scanning acoustic microscope in analyzing microglia's shape, motility, and response to inflammation.


Subject(s)
Microglia , Microscopy, Acoustic , Rats , Animals , Electric Impedance , Microscopy, Acoustic/methods , Acoustics , Adenosine Triphosphate/pharmacology , Inflammation/diagnostic imaging
11.
Graefes Arch Clin Exp Ophthalmol ; 262(4): 1245-1252, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37938376

ABSTRACT

PURPOSE: To evaluate the anterior segment structures using ultrasound biomicroscopy (UBM) in primary congenital glaucoma (PCG) and explore their correlation with disease severity and surgical outcomes. METHODS: Clinical information of PCG patients who underwent UBM prior to their first glaucoma surgeries from September 2014 to March 2021 were reviewed. The study included 214 UBM images of 154 PCG eyes and 60 fellow unaffected eyes. Anterior segment characteristics were analyzed. UBM parameters, including the iris thickness (IT) at variant distances from the pupil edge and iris root, anterior chamber depth (ACD), and pupil diameter (PD), were compared between two groups and their relationship with clinical factors and surgical outcomes were analyzed in PCG eyes. RESULTS: PCG eyes had unclear scleral spur, thin iris, wide anterior chamber angle, deep anterior chamber, rarefied ciliary body, elongated ciliary processes, and abnormal anterior iris insertion. ITs were thinner, ACD was deeper, and PD was larger in PCG eyes than fellow unaffected eyes (all P < 0.001). In PCG eyes, thinner ITs correlated with bilateral involvement and earlier age at presentation, and larger PD correlated with earlier age at presentation (P = 0.030) and higher intraocular pressure (P < 0.001). Thinner IT2 (P = 0.046) and larger PD (P = 0.049) were identified as risk factors for surgical failure. CONCLUSION: UBM is a powerful technique to exam anterior segment structures in PCG. The anatomical features are associated with disease severity and surgical outcomes, providing essential clinical insights.


Subject(s)
Glaucoma, Angle-Closure , Glaucoma , Humans , Microscopy, Acoustic/methods , Ciliary Body/diagnostic imaging , Iris/diagnostic imaging , Glaucoma/diagnosis , Glaucoma/surgery , Glaucoma/congenital , Patient Acuity , Treatment Outcome , Glaucoma, Angle-Closure/surgery , Anterior Eye Segment/diagnostic imaging , Intraocular Pressure
12.
Retina ; 44(5): 923-927, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38109723

ABSTRACT

PURPOSE: To demonstrate through a diagnostic test used as a new preoperative assessment that trocar insertion for pars plana vitrectomy could be safely placed at a distance >4.0 mm in highly myopic eyes to facilitate the surgical maneuvers. METHODS: Thirty eyes of 30 patients were tested with a biometer for the axial length measurement and with ultrasound biomicroscopy to measure the pars plana length. Pars plana lengths of highly myopic eyes were then compared with those of emmetropic eyes. The surgeon also measured the pars plana of highly myopic eyes intraoperatively and compared it with ultrasound measurements to assess ultrasound biomicroscopy reliability. RESULTS: The mean axial length was 23.81 mm (SD ± 0.30) in the control group and 31.11 mm (SD ± 0.56) in the myopic group. The mean pars plana length was 4.96 mm (SD ± 0.19) in control eyes and 6.65 (SD ± 0.36) in myopic eyes. An extremely significant statistical difference ( P < 0.001) was obtained by comparing the length of pars plana between control eyes and myopic eyes. The results of pars plana measurements were 6.65 mm (SD ± 0.36, ultrasound biomicroscopy) and 6.66 mm (SD ± 0.34, intraoperative measurements) in myopic eyes. The statistical comparison of the measurements in these two groups did not give a statistically significant result ( P = 0.950). CONCLUSION: Ultrasound biomicroscopy is a reliable technique to calculate the length of pars plana in highly myopic eyes, where this parameter is significantly greater than that of emmetropic eyes. Trocars insertion for pars plana vitrectomy may be performed, in eyes with axial length >30 mm, in relative safety at a distance to limbus higher than 4 mm.


Subject(s)
Axial Length, Eye , Microscopy, Acoustic , Myopia, Degenerative , Vitrectomy , Humans , Vitrectomy/methods , Female , Male , Middle Aged , Axial Length, Eye/diagnostic imaging , Axial Length, Eye/pathology , Myopia, Degenerative/surgery , Aged , Adult , Surgical Instruments , Reproducibility of Results , Biometry/methods
13.
IEEE Trans Med Imaging ; 43(5): 1690-1701, 2024 May.
Article in English | MEDLINE | ID: mdl-38145542

ABSTRACT

Ultrasound localization microscopy (ULM) allows for the generation of super-resolved (SR) images of the vasculature by precisely localizing intravenously injected microbubbles. Although SR images may be useful for diagnosing and treating patients, their use in the clinical context is limited by the need for prolonged acquisition times and high frame rates. The primary goal of our study is to relax the requirement of high frame rates to obtain SR images. To this end, we propose a new time-efficient ULM (TEULM) pipeline built on a cutting-edge interpolation method. More specifically, we suggest employing Radial Basis Functions (RBFs) as interpolators to estimate the missing values in the 2-dimensional (2D) spatio-temporal structures. To evaluate this strategy, we first mimic the data acquisition at a reduced frame rate by applying a down-sampling (DS = 2, 4, 8, and 10) factor to high frame rate ULM data. Then, we up-sample the data to the original frame rate using the suggested interpolation to reconstruct the missing frames. Finally, using both the original high frame rate data and the interpolated one, we reconstruct SR images using the ULM framework steps. We evaluate the proposed TEULM using four in vivo datasets, a Rat brain (dataset A), a Rat kidney (dataset B), a Rat tumor (dataset C) and a Rat brain bolus (dataset D), interpolating at the in-phase and quadrature (IQ) level. Results demonstrate the effectiveness of TEULM in recovering vascular structures, even at a DS rate of 10 (corresponding to a frame rate of sub-100Hz). In conclusion, the proposed technique is successful in reconstructing accurate SR images while requiring frame rates of one order of magnitude lower than standard ULM.


Subject(s)
Algorithms , Image Processing, Computer-Assisted , Animals , Rats , Image Processing, Computer-Assisted/methods , Microscopy, Acoustic/methods , Kidney/diagnostic imaging , Brain/diagnostic imaging , Brain/blood supply , Microbubbles , Microscopy/methods , Ultrasonography/methods
14.
Retin Cases Brief Rep ; 18(1): 29-31, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-35921626

ABSTRACT

PURPOSE: We report a novel method of intraoperative localization of a retained anterior intraocular foreign body (IOFB), using a combination of ultrasound biomicrosopy and an insulated needle. METHODS: A retrospective case report of a 56-year-old man who presented with a right eye IOFB. RESULTS: On presentation, vision was decreased in the right eye to count fingers with a small subconjunctival hemorrhage, but no other signs of a penetrating laceration. Orbital CT revealed an IOFB, and the initial vitrectomy failed to retrieve the IOFB. Then, during the subsequent vitrectomy, using an ultrasound compatible needle and an ultrasound biomicrosopy, we were able to precisely locate and remove the small anterior IOFB. CONCLUSION: Retained IOFBs can lead to severe irreversible vision loss if not promptly removed. Ancillary imaging modalities and localization techniques can help locate occult IOFBs in difficult cases.


Subject(s)
Eye Foreign Bodies , Eye Injuries, Penetrating , Male , Humans , Middle Aged , Retrospective Studies , Microscopy, Acoustic , Eye Injuries, Penetrating/diagnostic imaging , Eye Injuries, Penetrating/surgery , Eye Foreign Bodies/diagnostic imaging , Eye Foreign Bodies/surgery , Vitrectomy/methods
15.
J Neurosci Methods ; 401: 110005, 2024 01 01.
Article in English | MEDLINE | ID: mdl-37931754

ABSTRACT

BACKGROUND: Ischemic stroke represents a significant global health concern, necessitating thorough investigations and the utilization of stroke animal models to explore novel treatment modalities and diagnostic imaging techniques. NEW METHOD: Ultrasound biomicroscopy (BMU), operating at a center frequency of 21 MHz, along with ultrasound contrast agents (UCAs), was used to quantify microcirculation cerebral blood flow in a rat model of ischemic stroke. The microcirculation parameters were derived from time intensity curve (TIC) plots obtained based on UCA-bolus kinetics. RESULTS: Semiquantitative perfusion-related parameters were assessed. The TIC curves showed differences in amplitude when compared intra-animal between the left and right sides, and three situations were observed: normal perfusion, hypoperfusion, and nonperfusion. ROC analysis of delays between the left and right time intensity peak (TIP) for regions of interest (ROIs) in the control and stroke-hypoperfusion groups revealed an optimal cutpoint of 0.39 s to indicate when hypoperfusion is occurring in rats, with a sensitivity of 93.33 % and a specificity of 80 %. COMPARISON WITH EXISTING METHOD(S): Ultrasound perfusion imaging through the temporal bone window has been clinically applied to stroke patients using a UCA bolus for TIC analysis. TIC parameters were correlated with MRI- and CT-based measurements. CONCLUSIONS: This investigation quantified cerebral blood flow in a rat model of ischemic stroke by measuring microcirculation parameters. The study demonstrated the efficacy of this approach as a valuable tool for conducting preclinical studies.


Subject(s)
Ischemic Stroke , Stroke , Humans , Rats , Animals , Contrast Media , Microscopy, Acoustic , Stroke/diagnostic imaging , Brain/diagnostic imaging , Brain/blood supply , Ultrasonography/methods , Perfusion
16.
Sci Rep ; 13(1): 20642, 2023 11 24.
Article in English | MEDLINE | ID: mdl-38001251

ABSTRACT

Amyloid consists of insoluble beta-fibrillar proteins with stable structures. The Congo red staining method for histologically detecting amyloid is unsuitable for quantitatively assessing amyloid fibers. Scanning acoustic microscopy (SAM) detects the attenuation of sound (AOS) through sections. This study aimed to clarify whether AOS values reflected the amount of amyloid fibril degradation in tissues. Formalin-fixed paraffin-embedded unstained sections of various types of amyloidosis were digested with different endopeptidases. The AOS images after digestion were observed over time via SAM. The corresponding Congo red-stained images were followed to identify the amyloid. The amyloid and nonamyloid portions were statistically examined over time to determine the changes in the AOS values. Most of the amyloid areas showed significantly different AOS values from nonamyloid portions before digestion and significantly decreased after digestion; these findings corresponded with the disappearance and waning of the Congo red staining in the light microscopic images. Some nonamyloid areas with high AOS masked the reduction in AOS in the amyloid areas. The method used in this study may help detect the amyloid quantity and determine the appropriate treatment method for removing amyloid deposits from tissues.


Subject(s)
Amyloid , Congo Red , Amyloid/metabolism , Peptide Hydrolases , Microscopy, Acoustic/methods , Amyloidogenic Proteins/chemistry , Staining and Labeling , Endopeptidases
17.
BMC Ophthalmol ; 23(1): 480, 2023 Nov 22.
Article in English | MEDLINE | ID: mdl-37993828

ABSTRACT

BACKGROUND: The spatial position of the lens in patients with cortical age-related cataract (CARC) is unclear. We investigated a basis for the assessment of visual quality after cataract surgery by analysing the ultrasound biomicroscopic characteristics of the biological parameters of the lens in patients with CARC. METHODS: In this retrospective study, 119 patients (50 males and 69 females, totalling 238 eyes) with CARC who underwent simple cataract surgery were selected. The lens thickness (LT), axial length (AL), anterior chamber depth (ACD), lens vault (LV), trabecular-iris angle (TIA), iris-lens angle (ILA), iris-lens contact distance (ILCD) were measured by A-scan ultrasound and ultrasound biomicroscopy. The corresponding lens position (LP) and relative lens position (RLP) were calculated. RESULTS: LP was greater in men than in women (P < 0.05), LV was smaller in men than in women (P = 0.002), ILA and ILCD were not statistically significant (P = 0.072 and P = 0.854, respectively). There were significant differences in TIA, ILA, and ILCD in the four quadrants (all P < 0.05), with a trend in the distribution of TIA: superior < inferior < nasal < temporal, ILA: nasal < inferior < temporal < superior, and ILCD: superior < temporal < inferior < nasal. CONCLUSIONS: The lens protrudes more obviously in females than in males and the lens tilts to a certain extent with the increase of age and tends to be more upward and temporal in the supine position. Therefore, trends in lens-related parameters in patients with CARC should be taken seriously.


Subject(s)
Cataract , Glaucoma, Angle-Closure , Lens, Crystalline , Male , Humans , Female , Microscopy, Acoustic , Retrospective Studies , Lens, Crystalline/diagnostic imaging , Anterior Chamber/diagnostic imaging , Iris/diagnostic imaging
19.
Sci Rep ; 13(1): 16914, 2023 10 07.
Article in English | MEDLINE | ID: mdl-37805618

ABSTRACT

To examine the size of the ciliary body stroma (CBS) in dependence of the morphology of the anterior chamber angle in enucleated human eyes, we histomorphometrically examined human enucleated eyes. The study included 107 eyes (with a mean axial length of 25.1 ± 2.8 mm (range 21.0-36.0 mm). The anterior chamber angle was open in 68 eyes and it was closed and endothelialized in 39 eyes. The maximal CBS width (541 ± 210 µm versus 59 ± 179 µm; P < 0.001) and the minimal CBS width (214 ± 107 µm versus 17 ± 55 µm; P < 0.001) and maximal ciliary muscle height (593 ± 557 µm versus 293 ± 111 µm; P = 0.001) were significantly smaller in the angle-closure group than in the open-angle group. Maximal CBS width increased with presence of an open anterior chamber angle (beta: 0.82; B: 517; 95% CI 435, 599; P < 0.001) and longer axial length (beta: 0.17; B: 18.2; 95% CI 4.2, 32.2; P = 0.01). Minimal CBS width increased with the presence of an open anterior chamber angle (beta: 0.48; B: 131; 95% CI 80.4, 181; P < 0.001) and a larger maximal ciliary muscle height (beta: 0.33; B: 0.28; 95% CI 0.12, 0.44; P = 0.001). Maximal ciliary muscle height correlated with the maximal CBS height (beta: 0.35; B: 0.53; 95% CI 0.25, 0.81; P < 0.001). The findings suggest that the CBS size is markedly smaller in eyes with a chronically closed endothelialized anterior chamber angle than in eyes with open angles. The tightening of the angle in eyes with angle-closure may prevent the access of aqueous humor not only to the trabecular meshwork but also to the ciliary body and may reduce the uveoscleral or uveovortex outflow pathway.


Subject(s)
Ciliary Body , Glaucoma, Angle-Closure , Humans , Microscopy, Acoustic , Anterior Chamber/diagnostic imaging , Trabecular Meshwork/diagnostic imaging , Intraocular Pressure
20.
Vet Med Sci ; 9(6): 2458-2462, 2023 11.
Article in English | MEDLINE | ID: mdl-37733752

ABSTRACT

A 10-year-old spayed female Maltese dog was presented for hypotony of the right eye (OD) with decreased vision. The dorsomedial region of conjunctiva was partially swollen but the globe remained intact. Slit-lamp biomicroscopy revealed intraocular haemorrhage, uveitis, and a limbal, corneoconjunctival ulcer near the swollen conjunctiva. During ocular ultrasonography (OUS), the sclera became indented and hypotony occurred, implicating a full-thickness scleral wound. Ultrasound biomicroscopy (UBM) confirmed a full-thickness scleral defect, which was surgically apposed. The intraocular pressure normalised and the uveitis subsided post-operatively. OUS and UBM were helpful in suggesting and definitively diagnosing scleral perforation, leading to accurate treatment and good prognosis.


Subject(s)
Dog Diseases , Uveitis , Female , Dogs , Animals , Sclera/diagnostic imaging , Sclera/surgery , Microscopy, Acoustic/veterinary , Intraocular Pressure , Ultrasonography/veterinary , Uveitis/veterinary , Dog Diseases/diagnostic imaging , Dog Diseases/surgery
SELECTION OF CITATIONS
SEARCH DETAIL
...