Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 15.059
Filter
1.
Methods Cell Biol ; 187: 117-137, 2024.
Article in English | MEDLINE | ID: mdl-38705622

ABSTRACT

Correlative microscopy is an important approach for bridging the resolution gap between fluorescence light and electron microscopy. Here, we describe a fast and simple method for correlative immunofluorescence and immunogold labeling on the same section to elucidate the localization of phosphorylated vimentin (P-Vim), a robust feature of pulmonary vascular remodeling in cells of human lung small arteries. The lung is a complex, soft and difficult tissue to prepare for transmission electron microscopy (TEM). Detailing the molecular composition of small pulmonary arteries (<500µm) would be of great significance for research and diagnostics. Using the classical methods of immunochemistry (either hydrophilic resin or thin cryosections), is difficult to locate small arteries for analysis by TEM. To address this problem and to observe the same structures by both light and electron microscopy, correlative microscopy is a reliable approach. Immunofluorescence enables us to know the distribution of P-Vim in cells but does not provide ultrastructural detail on its localization. Labeled structures selected by fluorescence microscope can be identified and further analyzed by TEM at high resolution. With our method, the morphology of the arteries is well preserved, enabling the localization of P-Vim inside pulmonary endothelial cells. By applying this approach, fluorescent signals can be directly correlated to the corresponding subcellular structures in areas of interest.


Subject(s)
Lung , Vimentin , Humans , Vimentin/metabolism , Phosphorylation , Lung/metabolism , Lung/ultrastructure , Microscopy, Fluorescence/methods , Pulmonary Artery/metabolism , Pulmonary Artery/cytology , Pulmonary Artery/ultrastructure , Fluorescent Antibody Technique/methods , Endothelial Cells/metabolism , Endothelial Cells/ultrastructure , Microscopy, Electron, Transmission/methods , Microscopy, Electron/methods
2.
Nat Commun ; 15(1): 3657, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38719795

ABSTRACT

Cell states are regulated by the response of signaling pathways to receptor ligand-binding and intercellular interactions. High-resolution imaging has been attempted to explore the dynamics of these processes and, recently, multiplexed imaging has profiled cell states by achieving a comprehensive acquisition of spatial protein information from cells. However, the specificity of antibodies is still compromised when visualizing activated signals. Here, we develop Precise Emission Canceling Antibodies (PECAbs) that have cleavable fluorescent labeling. PECAbs enable high-specificity sequential imaging using hundreds of antibodies, allowing for reconstruction of the spatiotemporal dynamics of signaling pathways. Additionally, combining this approach with seq-smFISH can effectively classify cells and identify their signal activation states in human tissue. Overall, the PECAb system can serve as a comprehensive platform for analyzing complex cell processes.


Subject(s)
Fluorescent Antibody Technique , Humans , Fluorescent Antibody Technique/methods , Signal Transduction , Antibodies/immunology , Animals , In Situ Hybridization, Fluorescence/methods , Microscopy, Fluorescence/methods , Fluorescent Dyes/chemistry , Single Molecule Imaging/methods
3.
Sci Rep ; 14(1): 10524, 2024 05 08.
Article in English | MEDLINE | ID: mdl-38719976

ABSTRACT

Extracellular matrix diseases like fibrosis are elusive to diagnose early on, to avoid complete loss of organ function or even cancer progression, making early diagnosis crucial. Imaging the matrix densities of proteins like collagen in fixed tissue sections with suitable stains and labels is a standard for diagnosis and staging. However, fine changes in matrix density are difficult to realize by conventional histological staining and microscopy as the matrix fibrils are finer than the resolving capacity of these microscopes. The dyes further blur the outline of the matrix and add a background that bottlenecks high-precision early diagnosis of matrix diseases. Here we demonstrate the multiple signal classification method-MUSICAL-otherwise a computational super-resolution microscopy technique to precisely estimate matrix density in fixed tissue sections using fibril autofluorescence with image stacks acquired on a conventional epifluorescence microscope. We validated the diagnostic and staging performance of the method in extracted collagen fibrils, mouse skin during repair, and pre-cancers in human oral mucosa. The method enables early high-precision label-free diagnosis of matrix-associated fibrotic diseases without needing additional infrastructure or rigorous clinical training.


Subject(s)
Microscopy, Fluorescence , Animals , Mice , Humans , Microscopy, Fluorescence/methods , Extracellular Matrix Proteins/metabolism , Optical Imaging/methods , Extracellular Matrix/metabolism , Collagen/metabolism , Mouth Mucosa/metabolism , Mouth Mucosa/pathology , Skin/metabolism , Skin/pathology
4.
Int J Mol Sci ; 25(9)2024 Apr 25.
Article in English | MEDLINE | ID: mdl-38731890

ABSTRACT

Surpassing the diffraction barrier revolutionized modern fluorescence microscopy. However, intrinsic limitations in statistical sampling, the number of simultaneously analyzable channels, hardware requirements, and sample preparation procedures still represent an obstacle to its widespread diffusion in applicative biomedical research. Here, we present a novel pipeline based on automated multimodal microscopy and super-resolution techniques employing easily available materials and instruments and completed with open-source image-analysis software developed in our laboratory. The results show the potential impact of single-molecule localization microscopy (SMLM) on the study of biomolecules' interactions and the localization of macromolecular complexes. As a demonstrative application, we explored the basis of p53-53BP1 interactions, showing the formation of a putative macromolecular complex between the two proteins and the basal transcription machinery in situ, thus providing visual proof of the direct role of 53BP1 in sustaining p53 transactivation function. Moreover, high-content SMLM provided evidence of the presence of a 53BP1 complex on the cell cytoskeleton and in the mitochondrial space, thus suggesting the existence of novel alternative 53BP1 functions to support p53 activity.


Subject(s)
Tumor Suppressor Protein p53 , Tumor Suppressor p53-Binding Protein 1 , Tumor Suppressor Protein p53/metabolism , Humans , Tumor Suppressor p53-Binding Protein 1/metabolism , Single Molecule Imaging/methods , Microscopy, Fluorescence/methods , Protein Binding , Cell Line, Tumor , Mitochondria/metabolism
5.
Int J Mol Sci ; 25(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38731924

ABSTRACT

Förster resonance energy transfer (FRET) spectrometry is a method for determining the quaternary structure of protein oligomers from distributions of FRET efficiencies that are drawn from pixels of fluorescence images of cells expressing the proteins of interest. FRET spectrometry protocols currently rely on obtaining spectrally resolved fluorescence data from intensity-based experiments. Another imaging method, fluorescence lifetime imaging microscopy (FLIM), is a widely used alternative to compute FRET efficiencies for each pixel in an image from the reduction of the fluorescence lifetime of the donors caused by FRET. In FLIM studies of oligomers with different proportions of donors and acceptors, the donor lifetimes may be obtained by fitting the temporally resolved fluorescence decay data with a predetermined number of exponential decay curves. However, this requires knowledge of the number and the relative arrangement of the fluorescent proteins in the sample, which is precisely the goal of FRET spectrometry, thus creating a conundrum that has prevented users of FLIM instruments from performing FRET spectrometry. Here, we describe an attempt to implement FRET spectrometry on temporally resolved fluorescence microscopes by using an integration-based method of computing the FRET efficiency from fluorescence decay curves. This method, which we dubbed time-integrated FRET (or tiFRET), was tested on oligomeric fluorescent protein constructs expressed in the cytoplasm of living cells. The present results show that tiFRET is a promising way of implementing FRET spectrometry and suggest potential instrument adjustments for increasing accuracy and resolution in this kind of study.


Subject(s)
Feasibility Studies , Fluorescence Resonance Energy Transfer , Microscopy, Fluorescence , Fluorescence Resonance Energy Transfer/methods , Microscopy, Fluorescence/methods , Humans , Green Fluorescent Proteins/metabolism , Green Fluorescent Proteins/chemistry , Spectrometry, Fluorescence/methods , Luminescent Proteins/chemistry , Luminescent Proteins/metabolism , Fluorescence
6.
Opt Lett ; 49(10): 2621-2624, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748120

ABSTRACT

Fluorescence fluctuation super-resolution microscopy (FF-SRM) has emerged as a promising method for the fast, low-cost, and uncomplicated imaging of biological specimens beyond the diffraction limit. Among FF-SRM techniques, super-resolution radial fluctuation (SRRF) microscopy is a popular technique but is prone to artifacts, resulting in low fidelity, especially under conditions of high-density fluorophores. In this Letter, we developed a novel, to the best of our knowledge, combinatory computational super-resolution microscopy method, namely VeSRRF, that demonstrated superior performance in SRRF microscopy. VeSRRF combined intensity and gradient variance reweighted radial fluctuations (VRRF) and enhanced-SRRF (eSRRF) algorithms, leveraging the enhanced resolution achieved through intensity and gradient variance analysis in VRRF and the improved fidelity obtained from the radial gradient convergence transform in eSRRF. Our method was validated using microtubules in mammalian cells as a standard biological model system. Our results demonstrated that VeSRRF consistently achieved the highest resolution and exceptional fidelity compared to those obtained from other algorithms in both single-molecule localization microscopy (SMLM) and FF-SRM. Moreover, we developed the VeSRRF software package that is freely available on the open-source ImageJ/Fiji software platform to facilitate the use of VeSRRF in the broader community of biomedical researchers. VeSRRF is an exemplary method in which complementary microscopy techniques are integrated holistically, creating superior imaging performance and capabilities.


Subject(s)
Algorithms , Microscopy, Fluorescence , Microscopy, Fluorescence/methods , Microtubules , Image Processing, Computer-Assisted/methods , Animals , Software
7.
Methods Mol Biol ; 2807: 61-76, 2024.
Article in English | MEDLINE | ID: mdl-38743221

ABSTRACT

The 20-year revolution in optical fluorescence microscopy, supported by the optimization of both spatial resolution and timely acquisition, allows the visualization of nanoscaled objects in cell biology. Currently, the use of a recent generation of super-resolution fluorescence microscope coupled with improved fluorescent probes gives the possibility to study the replicative cycle of viruses in living cells, at the single-virus particle or protein level. Here, we highlight the protocol for visualizing HIV-1 Gag assembly at the host T-cell plasma membrane using super-resolution light microscopy. Total internal reflection fluorescence microscopy (TIRF-M) coupled with single-molecule localization microscopy (SMLM) enables the detection and characterization of the assembly of viral proteins at the plasma membrane of infected host cells at the single protein level. Here, we describe the TIRF equipment, the T-cell culture for HIV-1, the sample preparation for single-molecule localization microscopies such as PALM and STORM, acquisition protocols, and Gag assembling cluster analysis.


Subject(s)
Cell Membrane , HIV-1 , Microscopy, Fluorescence , Single Molecule Imaging , T-Lymphocytes , Virus Assembly , gag Gene Products, Human Immunodeficiency Virus , HIV-1/physiology , Humans , Cell Membrane/metabolism , Cell Membrane/virology , Single Molecule Imaging/methods , T-Lymphocytes/virology , T-Lymphocytes/metabolism , Microscopy, Fluorescence/methods , gag Gene Products, Human Immunodeficiency Virus/metabolism
8.
Methods Mol Biol ; 2807: 3-14, 2024.
Article in English | MEDLINE | ID: mdl-38743217

ABSTRACT

To successfully infect a cell, HIV-1 has to overcome several host barriers while exploiting cellular cofactors. HIV-1 infection is highly inefficient with the great majority of viral particles not being able to successfully integrate into the target cell genome. Nonproductive HIV-1 particles are degraded or accumulated in cellular compartments. Thus, it becomes hard to distinguish between viral behaviors that lead to effectively infecting the cell from the ones that do not by using traditional methods. Here, we describe the infectious virus tracking method that detects and quantifies individual fluorescent viral particles over time and links viral particle behavior to its infectivity. This method employs live-cell imaging at ultra-low MOIs to detect the outcome of infection for every HIV-1 particle.


Subject(s)
HIV-1 , HIV-1/physiology , Humans , Virion , HIV Infections/virology , Microscopy, Fluorescence/methods , Cells, Cultured
9.
Methods Mol Biol ; 2807: 77-91, 2024.
Article in English | MEDLINE | ID: mdl-38743222

ABSTRACT

HIV-1 virions incorporate viral RNA, cellular RNAs, and proteins during the assembly process. Some of these components, such as the viral RNA genome and viral proteins, are essential for viral replication, whereas others, such as host innate immune proteins, can inhibit virus replication. Therefore, analyzing the virion content is an integral part of studying HIV-1 replication. Traditionally, virion contents have been examined using biochemical assays, which can provide information on the presence or absence of the molecule of interest but not its distribution in the virion population. Here, we describe a method, single-virion analysis, that directly examines the presence of molecules of interest in individual viral particles using fluorescence microscopy. Thus, this method can detect both the presence and the distribution of molecules of interest in the virion population. Single-virion analysis was first developed to study HIV-1 RNA genome packaging. In this assay, HIV-1 unspliced RNA is labeled with a fluorescently tagged RNA-binding protein (protein A) and some of the Gag proteins are labeled with a different fluorescent protein (protein B). Using fluorescence microscopy, HIV-1 particles can be identified by the fluorescent protein B signal and the presence of unspliced HIV-1 RNA can be identified by the fluorescent protein A signal. Therefore, the proportions of particles that contain unspliced RNA can be determined by the fraction of Gag particles that also have a colocalized RNA signal. By tagging the molecule of interest with fluorescent proteins, single-virion analysis can be easily adapted to study the incorporation of other viral or host cell molecules into particles. Indeed, this method has been adapted to examine the proportion of HIV-1 particles that contain APOBEC3 proteins and the fraction of particles that contain a modified Gag protein. Therefore, single-virion analysis is a flexible method to study the nucleic acid and protein content of HIV-1 particles.


Subject(s)
HIV-1 , Microscopy, Fluorescence , RNA, Viral , Virion , HIV-1/physiology , HIV-1/genetics , Virion/metabolism , Microscopy, Fluorescence/methods , Humans , RNA, Viral/genetics , RNA, Viral/metabolism , Virus Assembly , Virus Replication , HIV Infections/virology , HIV Infections/metabolism
10.
Methods Mol Biol ; 2807: 113-125, 2024.
Article in English | MEDLINE | ID: mdl-38743224

ABSTRACT

The postnuclear entry steps of HIV-1 involve reverse transcription, uncoating, and integration into the host genome. The differential regulation of these steps has a significant impact on HIV overall replication, including integration site selection and viral gene expression. Recently, another important phenomenon has been uncovered as part of HIV interplay with the nuclear environment, specifically involving the cleavage and polyadenylation specific factor 6 (CPSF6) protein. This phenomenon is the formation of nuclear HIV-induced membraneless organelles (HIV-1 MLOs). In this article, we will describe the methods used to assess the composition and liquid-liquid phase separation (LLPS) properties of these organelles using fluorescence microscopy. The study of HIV-1 MLOs represents a new frontier that may reveal previously unknown key players in the fate of HIV-infected cells.


Subject(s)
Cell Nucleus , HIV-1 , Microscopy, Fluorescence , Humans , Microscopy, Fluorescence/methods , HIV-1/physiology , HIV-1/genetics , Cell Nucleus/metabolism , Organelles/metabolism , HIV Infections/virology , HIV Infections/metabolism
11.
Sci Adv ; 10(19): eadi6770, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38718114

ABSTRACT

Tracking stem cell fate transition is crucial for understanding their development and optimizing biomanufacturing. Destructive single-cell methods provide a pseudotemporal landscape of stem cell differentiation but cannot monitor stem cell fate in real time. We established a metabolic optical metric using label-free fluorescence lifetime imaging microscopy (FLIM), feature extraction and machine learning-assisted analysis, for real-time cell fate tracking. From a library of 205 metabolic optical biomarker (MOB) features, we identified 56 associated with hematopoietic stem cell (HSC) differentiation. These features collectively describe HSC fate transition and detect its bifurcate lineage choice. We further derived a MOB score measuring the "metabolic stemness" of single cells and distinguishing their division patterns. This score reveals a distinct role of asymmetric division in rescuing stem cells with compromised metabolic stemness and a unique mechanism of PI3K inhibition in promoting ex vivo HSC maintenance. MOB profiling is a powerful tool for tracking stem cell fate transition and improving their biomanufacturing from a single-cell perspective.


Subject(s)
Biomarkers , Cell Differentiation , Cell Lineage , Hematopoietic Stem Cells , Biomarkers/metabolism , Animals , Hematopoietic Stem Cells/metabolism , Hematopoietic Stem Cells/cytology , Mice , Cell Tracking/methods , Single-Cell Analysis/methods , Microscopy, Fluorescence/methods , Humans
12.
Methods Cell Biol ; 187: 1-41, 2024.
Article in English | MEDLINE | ID: mdl-38705621

ABSTRACT

Correlative light and electron microscopy (CLEM) is an approach that combines the strength of multiple imaging techniques to obtain complementary information about a given specimen. The "toolbox" for CLEM is broad, making it sometimes difficult to choose an appropriate approach for a given biological question. In this chapter, we provide experimental details for three CLEM approaches that can help the interested reader in designing a personalized CLEM strategy for obtaining ultrastructural data by using transmission electron microscopy (TEM). First, we describe chemical fixation of cells grown on a solid support (broadest approach). Second, we apply high-pressure freezing/freeze substitution to describe cellular ultrastructure (cryo-immobilization approach). Third, we give a protocol for a ultrastructural labeling by immuno-electron microscopy (immuno-EM approach). In addition, we also describe how to overlay fluorescence and electron microscopy images, an approach that is applicable to each of the reported different CLEM strategies. Here we provide step-by step descriptions prior to discussing possible technical problems and variations of these three general schemes to suit different models or different biological questions. This chapter is written for electron microscopists that are new to CLEM and unsure how to begin. Therefore, our protocols are meant to provide basic information with further references that should help the reader get started with applying a tailored strategy for a specific CLEM experiment.


Subject(s)
Microscopy, Electron, Transmission , Humans , Microscopy, Electron, Transmission/methods , Animals , Cryoelectron Microscopy/methods , Microscopy, Electron/methods , Microscopy, Immunoelectron/methods , Microscopy, Fluorescence/methods , Freeze Substitution/methods
13.
Methods Cell Biol ; 187: 205-222, 2024.
Article in English | MEDLINE | ID: mdl-38705625

ABSTRACT

Correlated super-resolution fluorescence microscopy and cryo-electron microscopy enables imaging with both high labeling specificity and high resolution. Naturally, combining two sophisticated imaging techniques within one workflow also introduces new requirements on hardware, such as the need for a super-resolution fluorescence capable microscope that can be used to image cryogenic samples. In this chapter, we describe the design and use of the "cryoscope"; a microscope designed for single-molecule localization microscopy (SMLM) of cryoEM samples that fits right into established cryoEM workflows. We demonstrate the results that can be achieved with our microscope by imaging fluorescently labeled vimentin, an intermediate filament, within U2OS cells grown on EM grids, and we provide detailed 3d models that encompass the entire design of the microscope.


Subject(s)
Cryoelectron Microscopy , Microscopy, Fluorescence , Microscopy, Fluorescence/methods , Cryoelectron Microscopy/methods , Humans , Vimentin/metabolism , Imaging, Three-Dimensional/methods , Single Molecule Imaging/methods , Cell Line, Tumor
14.
Methods Cell Biol ; 187: 293-320, 2024.
Article in English | MEDLINE | ID: mdl-38705628

ABSTRACT

Cryo-soft X-ray tomography is the unique technology that can image whole intact cells in 3D under normal and pathological conditions without labelling or fixation, at high throughput and spatial resolution. The sample preparation is relatively straightforward; requiring just fast freezing of the specimen before transfer to the microscope for imaging. It is also possible to image chemically fixed samples where necessary. The technique can be correlated with cryo fluorescence microscopy to localize fluorescent proteins to organelles within the whole cell volume. Cryo-correlated light and soft X-ray tomography is particularly useful for the study of gross morphological changes brought about by disease or drugs. For example, viral fluorescent tags can be co-localized to sites of viral replication in the soft X-ray volume. In general this approach is extremely useful in the study of complex 3D organelle structure, nanoparticle uptake or in the detection of rare events in the context of whole cell structure. The main challenge of soft X-ray tomography is that the soft X-ray illumination required for imaging has heretofore only been available at a small number of synchrotron labs worldwide. Recently, a compact device with a footprint small enough to fit in a standard laboratory setting has been deployed ("the SXT-100") and is routinely imaging cryo prepared samples addressing a variety of disease and drug research applications. The SXT-100 facilitates greater access to this powerful technique and greatly increases the scope and throughput of potential research projects. Furthermore, the availability of cryo-soft X-ray tomography in the laboratory will accelerate the development of novel correlative and multimodal workflows by integration with light and electron microscope based approaches. It also allows for co-location of this powerful imaging modality at BSL3 labs or other facilities where safety or intellectual property considerations are paramount. Here we describe the compact SXT-100 microscope along with its novel integrated cryo-fluorescence imaging capability.


Subject(s)
Microscopy, Fluorescence , Tomography, X-Ray , Microscopy, Fluorescence/methods , Tomography, X-Ray/methods , Humans , Imaging, Three-Dimensional/methods , Animals , Cryopreservation/methods
15.
Methods Cell Biol ; 187: 175-203, 2024.
Article in English | MEDLINE | ID: mdl-38705624

ABSTRACT

Correlative cryo-microscopy pipelines combining light and electron microscopy and tomography in cryogenic conditions (cryoCLEM) on the same sample are powerful methods for investigating the structure of specific cellular targets identified by a fluorescent tag within their unperturbed cellular environment. CryoCLEM approaches circumvent one of the inherent limitations of cryo EM, and specifically cryo electron tomography (cryoET), of identifying the imaged structures in the crowded 3D environment of cells. Whereas several cryoCLEM approaches are based on thinning the sample by cryo FIB milling, here we present detailed protocols of two alternative cryoCLEM approaches for in situ studies of adherent cells at the single-cell level without the need for such cryo-thinning. The first approach is a complete cryogenic pipeline in which both fluorescence and electronic imaging are performed on frozen-hydrated samples, the second is a hybrid cryoCLEM approach in which fluorescence imaging is performed at room temperature, followed by rapid freezing and subsequent cryoEM imaging. We provide a detailed description of the two methods we have employed for imaging fluorescently labeled cellular structures with thickness below 350-500nm, such as cell protrusions and organelles located in the peripheral areas of the cells.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Humans , Electron Microscope Tomography/methods , Microscopy, Fluorescence/methods , Imaging, Three-Dimensional/methods , Single-Cell Analysis/methods , Animals
16.
Methods Cell Biol ; 187: 249-292, 2024.
Article in English | MEDLINE | ID: mdl-38705627

ABSTRACT

Cryogenic ultrastructural imaging techniques such as cryo-electron tomography have produced a revolution in how the structure of biological systems is investigated by enabling the determination of structures of protein complexes immersed in a complex biological matrix within vitrified cell and model organisms. However, so far, the portfolio of successes has been mostly limited to highly abundant complexes or to structures that are relatively unambiguous and easy to identify through electron microscopy. In order to realize the full potential of this revolution, researchers would have to be able to pinpoint lower abundance species and obtain functional annotations on the state of objects of interest which would then be correlated to ultrastructural information to build a complete picture of the structure-function relationships underpinning biological processes. Fluorescence imaging at cryogenic conditions has the potential to be able to meet these demands. However, wide-field images acquired at low numeric aperture (NA) using air immersion objective have a low resolving power and cannot provide accurate enough three-dimensional (3D) localization to enable the assignment of functional annotations to individual objects of interest or target sample debulking to ensure the preservation of the structures of interest. It is therefore necessary to develop super-resolved cryo-fluorescence workflows capable of fulfilling this role and enabling new biological discoveries. In this chapter, we present the current state of development of two super-resolution cryogenic fluorescence techniques, superSIL-STORM and astigmatism-based 3D STORM, show their application to a variety of biological systems and discuss their advantages and limitations. We further discuss the future applicability to cryo-CLEM workflows though examples of practical application to the study of membrane protein complexes both in mammalian cells and in Escherichia coli.


Subject(s)
Cryoelectron Microscopy , Cryoelectron Microscopy/methods , Humans , Animals , Imaging, Three-Dimensional/methods , Electron Microscope Tomography/methods , Image Processing, Computer-Assisted/methods , Microscopy, Fluorescence/methods
17.
Methods Cell Biol ; 187: 43-56, 2024.
Article in English | MEDLINE | ID: mdl-38705629

ABSTRACT

Correlative Light Electron Microscopy (CLEM) encompasses a wide range of experimental approaches with different degrees of complexity and technical challenges where the attributes of both light and electron microscopy are combined in a single experiment. Although the biological question always determines what technology is the most appropriate, we generally set out to apply the simplest workflow possible. For 2D cell cultures expressing fluorescently tagged molecules, we report on a simple and very powerful CLEM approach by using gridded finder imaging dishes. We first determine the gross localization of the fluorescence using light microscopy and subsequently we retrace the origin/localization of the fluorescence by projecting it onto the ultrastructural reference space obtained by transmission electron microscopy (TEM). Here we describe this workflow and highlight some basic principles of the sample preparation for such a simple CLEM experiment. We will specifically focus on the steps following the resin embedding for TEM and the introduction of the sample in the electron microscope.


Subject(s)
Workflow , Humans , Microscopy, Fluorescence/methods , Microscopy, Electron, Transmission/methods , Microscopy, Electron/methods , Animals
18.
Methods Mol Biol ; 2800: 89-102, 2024.
Article in English | MEDLINE | ID: mdl-38709480

ABSTRACT

In recent years, Correlative Multimodal Imaging (CMI) has become an "en vogue" technique and a bit of a buzzword. It entails combining information from different imaging modalities to extract more information from a sample that would otherwise not be possible from each individual technique. The best established CMI technology is correlative light and electron microscopy (CLEM), which applies light and electron microscopy on the exact same sample/structure. In general, it entails the detection of fluorescently tagged proteins or structures by light microscopy and subsequently their relative intracellular localization is determined with nanometer resolution using transmission electron microscopy (TEM). Here, we describe the different steps involved in a "simple" CLEM approach. We describe the overall workflow, instrumentation, and basic principles of sample preparation for a CLEM experiment exploiting stable expression of fluorescent proteins.


Subject(s)
Microscopy, Electron, Transmission , Humans , Microscopy, Electron, Transmission/methods , Microscopy, Fluorescence/methods , Microscopy, Electron/methods , Image Processing, Computer-Assisted/methods , Animals
19.
Methods Mol Biol ; 2800: 103-113, 2024.
Article in English | MEDLINE | ID: mdl-38709481

ABSTRACT

The spatial resolution of conventional light microscopy is restricted by the diffraction limit to hundreds of nanometers. Super-resolution microscopy enables single digit nanometer resolution by circumventing the diffraction limit of conventional light microscopy. DNA point accumulation for imaging in nanoscale topography (DNA-PAINT) belongs to the family of single-molecule localization super-resolution approaches. Unique features of DNA-PAINT are that it allows for sub-nanometer resolution, spectrally unlimited multiplexing, proximity detection, and quantitative counting of target molecules. Here, we describe prerequisites for efficient DNA-PAINT microscopy.


Subject(s)
DNA , Single Molecule Imaging , DNA/chemistry , Single Molecule Imaging/methods , Microscopy, Fluorescence/methods , Proteins/chemistry , Nanotechnology/methods
20.
Brief Bioinform ; 25(3)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38704671

ABSTRACT

Computational analysis of fluorescent timelapse microscopy images at the single-cell level is a powerful approach to study cellular changes that dictate important cell fate decisions. Core to this approach is the need to generate reliable cell segmentations and classifications necessary for accurate quantitative analysis. Deep learning-based convolutional neural networks (CNNs) have emerged as a promising solution to these challenges. However, current CNNs are prone to produce noisy cell segmentations and classifications, which is a significant barrier to constructing accurate single-cell lineages. To address this, we developed a novel algorithm called Single Cell Track (SC-Track), which employs a hierarchical probabilistic cache cascade model based on biological observations of cell division and movement dynamics. Our results show that SC-Track performs better than a panel of publicly available cell trackers on a diverse set of cell segmentation types. This cell-tracking performance was achieved without any parameter adjustments, making SC-Track an excellent generalized algorithm that can maintain robust cell-tracking performance in varying cell segmentation qualities, cell morphological appearances and imaging conditions. Furthermore, SC-Track is equipped with a cell class correction function to improve the accuracy of cell classifications in multiclass cell segmentation time series. These features together make SC-Track a robust cell-tracking algorithm that works well with noisy cell instance segmentation and classification predictions from CNNs to generate accurate single-cell lineages and classifications.


Subject(s)
Algorithms , Cell Lineage , Cell Tracking , Single-Cell Analysis , Cell Tracking/methods , Single-Cell Analysis/methods , Humans , Image Processing, Computer-Assisted/methods , Neural Networks, Computer , Deep Learning , Microscopy, Fluorescence/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...