Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 10.787
Filter
1.
Int J Mol Sci ; 25(9)2024 May 05.
Article in English | MEDLINE | ID: mdl-38732246

ABSTRACT

Nanoparticles (NPs) have shown significant potential for pulmonary administration of therapeutics for the treatment of chronic lung diseases in a localized and sustained manner. Nebulization is a suitable method of NP delivery, particularly in patients whose ability to breathe is impaired due to lung diseases. However, there are limited studies evaluating the physicochemical properties of NPs after they are passed through a nebulizer. High shear stress generated during nebulization could potentially affect the surface properties of NPs, resulting in the loss of encapsulated drugs and alteration in the release kinetics. Herein, we thoroughly examined the physicochemical properties as well as the therapeutic effectiveness of Infasurf lung surfactant (IFS)-coated PLGA NPs previously developed by us after passing through a commercial Aeroneb® vibrating-mesh nebulizer. Nebulization did not alter the size, surface charge, IFS coating and bi-phasic release pattern exhibited by the NPs. However, there was a temporary reduction in the initial release of encapsulated therapeutics in the nebulized compared to non-nebulized NPs. This underscores the importance of evaluating the drug release kinetics of NPs using the inhalation method of choice to ensure suitability for the intended medical application. The cellular uptake studies demonstrated that both nebulized and non-nebulized NPs were less readily taken up by alveolar macrophages compared to lung cancer cells, confirming the IFS coating retention. Overall, nebulization did not significantly compromise the physicochemical properties as well as therapeutic efficacy of the prepared nanotherapeutics.


Subject(s)
Nanoparticles , Nebulizers and Vaporizers , Nanoparticles/chemistry , Humans , Administration, Inhalation , Drug Delivery Systems/methods , Lipids/chemistry , Drug Liberation , Lung/metabolism , Polymers/chemistry , Pulmonary Surfactants/chemistry , Drug Carriers/chemistry , Macrophages, Alveolar/metabolism , Macrophages, Alveolar/drug effects , Particle Size , A549 Cells , Animals , Surface Properties
2.
Nano Lett ; 24(20): 6102-6111, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38739578

ABSTRACT

Acute lung injury (ALI) is a severe inflammatory lung disease, with high mortality rates. Early intervention by reactive oxygen species (ROS) scavengers could reduce ROS accumulation, break the inflammation expansion chain in alveolar macrophages (AMs), and avoid irreversible damage to alveolar epithelial and endothelial cells. Here, we reported cell-penetrating R9 peptide-modified triangular DNA origami nanostructures (tDONs-R9) as a novel nebulizable drug that could reach the deep alveolar regions and exhibit an enhanced uptake preference of macrophages. tDONs-R9 suppressed the expression of pro-inflammatory cytokines and drove polarization toward the anti-inflammatory M2 phenotype in macrophages. In the LPS-induced ALI mouse model, treatment with nebulized tDONs-R9 alleviated the overwhelming ROS, pro-inflammatory cytokines, and neutrophil infiltration in the lungs. Our study demonstrates that tDONs-R9 has the potential for ALI treatment, and the programmable DNA origami nanostructures provide a new drug delivery platform for pulmonary disease treatment with high delivery efficiency and biosecurity.


Subject(s)
Acute Lung Injury , DNA , Nanostructures , Acute Lung Injury/drug therapy , Acute Lung Injury/pathology , Acute Lung Injury/chemically induced , Animals , Mice , DNA/chemistry , Administration, Inhalation , Nanostructures/chemistry , Reactive Oxygen Species/metabolism , Macrophages, Alveolar/drug effects , Macrophages, Alveolar/metabolism , Cytokines/metabolism , Peptides/chemistry , Nebulizers and Vaporizers , Cell-Penetrating Peptides/chemistry , Disease Models, Animal , Lipopolysaccharides , Drug Delivery Systems , RAW 264.7 Cells
3.
Ther Adv Respir Dis ; 18: 17534666241232264, 2024.
Article in English | MEDLINE | ID: mdl-38698565

ABSTRACT

What is this summary about?This summary describes the results of a clinical study called MANDALA that was published in the New England Journal of Medicine in 2022. In the MANDALA study, researchers looked at a new asthma rescue inhaler that contains both albuterol and budesonide in a single inhaler (known as albuterol-budesonide, AIRSUPRA™). This summary describes the results for people aged 18 yearsand older who took part in the study.


Subject(s)
Albuterol , Asthma , Bronchodilator Agents , Budesonide , Drug Combinations , Nebulizers and Vaporizers , Humans , Asthma/drug therapy , Albuterol/administration & dosage , Administration, Inhalation , Bronchodilator Agents/administration & dosage , Budesonide/administration & dosage , Adult , Middle Aged , Male , Female , Treatment Outcome , Adolescent , Young Adult , Aged , Anti-Asthmatic Agents/administration & dosage
4.
PLoS One ; 19(5): e0300241, 2024.
Article in English | MEDLINE | ID: mdl-38696384

ABSTRACT

OBJECTIVE: Technical ex-vivo comparison of commercial nebulizer nozzles used for Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC). METHODS: The performance of four different commercial nebulizer nozzles (Nebulizer; HurriChemTM; MCR-4 TOPOL®; QuattroJet) was analysed concerning: i) technical design and principle of operation, ii) operational pressure as function of the liquid flow rate, iii) droplet size distribution via laser diffraction spectrometry, iv) spray cone angle, spray cone form as well as horizontal drug deposition by image-metric analyses and v) chemical resistance via exposing to a cytostatic solution and chemical composition by means of spark optical emission spectral analysis. RESULTS: The Nebulizer shows quasi an identical technical design and thus also a similar performance (e.g., mass median droplet size of 29 µm) as the original PIPAC nozzles (MIP/ CapnoPen). All other nozzles show more or less a performance deviation to the original PIPAC nozzles. The HurriChemTM has a similar design and principle of operation as the Nebulizer, but provides a finer aerosol (22 µm). The principle of operation of MCR-4 TOPOL® and QuattroJet differ significantly from that of the original PIPAC nozzle technology. The MCR-4 TOPOL® offers a hollow spray cone with significantly larger droplets (50 µm) than the original PIPAC nozzles. The QuattroJet generates an aerosol (22 µm) similar to that of the HurriChemTM but with improved spatial drug distribution. CONCLUSION: The availability of new PIPAC nozzles is encouraging but can also have a negative impact if their performance and efficacy is unknown. It is recommended that PIPAC nozzles that deviate from the current standard should be subject to bioequivalence testing and implementation in accordance with the IDEAL-D framework prior to routine clinical use.


Subject(s)
Aerosols , Nebulizers and Vaporizers , Humans , Antineoplastic Agents/administration & dosage , Pressure , Particle Size , Equipment Design
5.
BMJ Open Respir Res ; 11(1)2024 May 21.
Article in English | MEDLINE | ID: mdl-38772900

ABSTRACT

BACKGROUND: Compared with multiple-inhaler triple therapy (MITT), single-inhaler triple therapy (SITT) with fluticasone furoate/umeclidinium/vilanterol (FF/UMEC/VI) demonstrated improved lung function and meaningful improvements in chronic obstructive pulmonary disease (COPD) Assessment Test score. This real-world study compared the effectiveness of switching patients with COPD in England from MITT to once-daily SITT with FF/UMEC/VI by evaluating rates of COPD exacerbation, healthcare resource use (HCRU) and associated direct medical costs. METHODS: Retrospective cohort pre-post study using linked primary care electronic health record and secondary care administrative datasets. Patients diagnosed with COPD at age ≥35 years, with smoking history, linkage to secondary care data and continuous GP registration for 12 months pre-switch and 6 months post-switch to FF/UMEC/VI were included. Index date was the first initiation of an FF/UMEC/VI prescription immediately following MITT use from 15 November 2017 to 30 September 2019. Baseline was 12 months prior to index, with outcomes assessed 6/12 months pre-switch and post-switch, and stratified by prior COPD exacerbation status. RESULTS: We included 2533 patients (mean [SD] age: 71.1 [9.9] years; 52.1% male). In the 6 months post-switch, there were significant decreases in the proportion of patients experiencing ≥1 moderate-to-severe (36.2%-28.9%), moderate only (24.4%-19.8%) and severe only (15.4%-11.8%) COPD exacerbation (each, p<0.0001) compared with the 6 months pre-switch. As demonstrated by rate ratios, there were significant reductions in exacerbation rates of each severity overall (p<0.01) and among patients with prior exacerbations (p<0.0001). In the same period, there were significant decreases in the rate of each COPD-related HCRU and total COPD-related costs (-24.9%; p<0.0001). CONCLUSION: Patients with COPD switching from MITT to once-daily SITT with FF/UMEC/VI in a primary care setting had significantly fewer moderate and severe exacerbations, and lower COPD-related HCRU and costs, in the 6 months post-switch compared with the 6 months pre-switch.


Subject(s)
Benzyl Alcohols , Bronchodilator Agents , Chlorobenzenes , Drug Combinations , Nebulizers and Vaporizers , Primary Health Care , Pulmonary Disease, Chronic Obstructive , Quinuclidines , Humans , Pulmonary Disease, Chronic Obstructive/drug therapy , Male , Retrospective Studies , Female , Aged , Middle Aged , Benzyl Alcohols/administration & dosage , Chlorobenzenes/administration & dosage , England , Administration, Inhalation , Bronchodilator Agents/administration & dosage , Quinuclidines/administration & dosage , Treatment Outcome , Muscarinic Antagonists/administration & dosage , Androstadienes
7.
Lancet Planet Health ; 8 Suppl 1: S5, 2024 04.
Article in English | MEDLINE | ID: mdl-38632920

ABSTRACT

BACKGROUND: The carbon footprint of Canada's health sector is among the worst in the world, responsible for 4·6% of Canada's total greenhouse gas emissions. A quarter of emissions from Canada's health sector are linked to pharmaceuticals, including metered dose inhalers (MDIs). MDIs use propellants, such as hydrofluorocarbons, which act as greenhouse gas emissions and contribute to the health-care sector's overall carbon footprint. The objective of this study was to describe MDI prescribing, dispensing, usage, and waste patterns at The Ottawa Hospital (Ottawa, ON, Canada). Secondary objectives included estimating the monetary and carbon cost of current practice and the potential benefits and costs of switching to the more environmentally friendly dry powder inhalers. METHODS: In this retrospective point-prevalence cohort study, we identified 100 consecutive patients from medical and surgical services at both campuses of The Ottawa Hospital from health records discharged from medical and surgical services and who were prescribed at least one MDI during their admission. Medical records were reviewed and data related to demographics, MDI prescribing, dispensing, usage, and wastage were collected using a pre-piloted electronic case report form. Financial cost was calculated using local costing estimates and carbon cost was calculated using published estimates. FINDINGS: Between Jan 1, 2023, and June 1, 2023, we collected data for 100 eligible patients, of whom 60 (60%) were female and 90 (90%) were admitted to hospital medicine wards (10% from surgical wards). The median length of stay was 7 (range 1-47) days. The most common inpatient diagnoses were respiratory tract infections in 43 (43%) of 100 patients and chronic obstructive pulmonary disease exacerbations in 28 (28%) of 100 patients. The median number of MDIs prescribed during a patients stay was two (range one to 15) and the median number dispensed was one (range one to seven). For formulary options of MDIs, of the 200 (range 30-1400) actuations dispensed per patient, 8% were used, representing 92% wastage. During the audit, 315 MDIs were dispensed in total, of which 97 were not used at all. INTERPRETATION: MDIs are significant contributors to the carbon footprint attributed to pharmaceutical use in hospitals. This study suggests that 90% of MDI doses are wasted, showing that there is substantial room for improvement. FUNDING: None.


Subject(s)
Greenhouse Gases , Humans , Female , Male , Cohort Studies , Retrospective Studies , Nebulizers and Vaporizers , Metered Dose Inhalers , Hospitals , Carbon
8.
Indian J Pharmacol ; 56(2): 105-111, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38687314

ABSTRACT

BACKGROUND: Sedative agents used in bronchoscopy require trained personnel to administer and monitor the patient. This increases the procedure cost, duration, and inpatient stay. Inhalational administration of sedative agents can be a practical solution to the issue. Dexmedetomidine in the inhalational form could give results similar to the intravenous form without significant adverse events. MATERIALS AND METHODS: The study is prospective, randomized, and double-blinded study. Patients needing bronchoscopy were randomized to receive the nebulized form of either dexmedetomidine or saline (0.9%) before bronchoscopy. The study parameters are assessed and recorded before, during, and after bronchoscopy. Data collected are analyzed using the SPSS software. DISCUSSION: The side effects limit using commonly administered sedation agents in bronchoscopy, such as midazolam, fentanyl, and dexmedetomidine. The nebulized dexmedetomidine is safe with proven efficacy when compared to the placebo. Proceduralist-administered conscious sedation reduces the overall cost and shortens inpatient stays. Attenuation of hemodynamic parameters by dexmedetomidine could be an advantage for the physician in reducing an untoward cardiac event. CONCLUSION: Dexmedetomidine in the nebulized form improves the comfort of patients during the procedure. It blunts the pressure response during bronchoscopy and could be a safer and cost-effective agent in its nebulized form for conscious sedation in bronchoscopy. The study is approved by the institutional ethics committee (IEC KMC MLR 10-2021-310).


Subject(s)
Bronchoscopy , Conscious Sedation , Dexmedetomidine , Hypnotics and Sedatives , Nebulizers and Vaporizers , Dexmedetomidine/administration & dosage , Humans , Conscious Sedation/methods , Hypnotics and Sedatives/administration & dosage , Double-Blind Method , India , Male , Female , Prospective Studies , Middle Aged , Adult , Administration, Inhalation
10.
BMC Pulm Med ; 24(1): 189, 2024 Apr 19.
Article in English | MEDLINE | ID: mdl-38641584

ABSTRACT

BACKGROUND: Nonadherence to therapies and psychological disorders are associated with poor asthma control. This study aims to assess the prevalence of anxiety and depressive symptoms, asthma control, and adherence to inhalers and to investigate whether there is an association of anxiety and depressive symptoms with adherence to inhalers and asthma control. METHODS: We measured anxiety and depressive symptoms using the Hospital Anxiety and Depression Scale in patients with asthma. Asthma Control Test and the 10-Item Test of Adherence to Inhalers Scale were used to assess levels of asthma control adherence to inhalers, respectively. Univariate and multivariate regression models assessed the associations of anxiety and depressive symptoms with adherence to inhalers and asthma control. RESULTS: A total of 287 patients completed the study, of whom 72% were female. The mean ± SD age and body mass index of our study population were 44 ± 13 years and 29 ± 7.2 kg/m2, respectively. Poor adherence to inhaler use was highly prevalent (49.8%; 95% CI: 43.8 to 55.7). The prevalence of anxiety, depression and poor asthma control was 27.2% (95% CI: 22.1 to 32.7), 20.9% (95% CI: 16.3 to 26.1), and 22.7% (95% CI: 17.9 to 27.9), respectively. We found a negative relationship between asthma control and anxiety, and depressive symptoms (adjusted ß: -0.25; 95% CI: -0.36 to -0.14; p < 0.001 and adjusted ß: -0.29; 95% CI: -0.40 to -0.18; p < 0.001, respectively). A negative relationship was also observed between adherence to inhalers and anxiety and depressive symptoms (adjusted ß: -0.34; 95% CI: -0.46 to -0.22; p < 0.001 and adjusted ß: -0.36; 95% CI: - 0.48 to - 0.24; p < 0.001, respectively). CONCLUSIONS: The high prevalence of uncontrolled asthma symptoms and poor adherence to inhalers and their impact on anxiety and depression levels among patients with asthma point to the need for early screening for psychological symptoms and recognition of nonadherence as part of asthma assessment and management plan in primary care in Saudi Arabia to avoid further worsening of asthma symptoms. Further studies are needed to explore the effectiveness of specific psychoeducational interventions and investigate the long-term impact of early psychological symptom detection on asthma outcomes.


Subject(s)
Anti-Asthmatic Agents , Asthma , Humans , Female , Male , Cross-Sectional Studies , Anti-Asthmatic Agents/therapeutic use , Asthma/drug therapy , Asthma/epidemiology , Asthma/psychology , Medication Adherence , Nebulizers and Vaporizers
11.
Article in English | MEDLINE | ID: mdl-38646606

ABSTRACT

Purpose: To assess patient characteristics of users and new initiators of triple therapy for chronic obstructive pulmonary disease (COPD) in Germany. Patients and Methods: Retrospective cohort study of patients with COPD and ≥1 prescription for single-inhaler triple therapy (SITT; fluticasone furoate/umeclidinium/vilanterol [FF/UMEC/VI] or beclomethasone dipropionate/glycopyrronium bromide/formoterol [BDP/GLY/FOR]) or multiple-inhaler triple therapy (MITT), using data from the AOK PLUS German sickness fund (1 January 2015-31 December 2019). The index date was the first date of prescription for FF/UMEC/VI or BDP/GLY/FOR (SITT users), or the first date of overlap of inhaled corticosteroid, long-acting ß2-agonist, and long-acting muscarinic antagonist (MITT users). Two cohorts were defined: the prevalent cohort included all identified triple therapy users; the incident cohort included patients newly initiating triple therapy for the first time (no prior use of MITT or SITT in the last 2 years). Patient characteristics and treatment patterns were assessed on the index date and during the 24-month pre-index period. Results: In total, 18,630 patients were identified as prevalent triple therapy users (MITT: 17,945; FF/UMEC/VI: 700; BDP/GLY/FOR: 908; non-mutually exclusive) and 2932 patients were identified as incident triple therapy initiators (MITT: 2246; FF/UMEC/VI: 311; BDP/GLY/FOR: 395; non-mutually exclusive). For both the prevalent and incident cohorts, more than two-thirds of patients experienced ≥1 moderate/severe exacerbation in the preceding 24 months; in both cohorts more BDP/GLY/FOR users experienced ≥1 moderate/severe exacerbation, compared with FF/UMEC/VI and MITT users. Overall, 97.9% of prevalent triple therapy users and 86.4% of incident triple therapy initiators received maintenance treatment in the 24-month pre-index period. Conclusion: In a real-world setting in Germany, triple therapy was most frequently used after maintenance therapy in patients with recent exacerbations, in line with current treatment recommendations.


Triple therapy (a combination of three different respiratory inhaled medications) is recommended for patients with chronic obstructive pulmonary disease (COPD) who experience repeated short-term symptom flare-ups when taking dual therapy (a combination of two different respiratory medications). Previously, patients had to take triple therapy using two or three separate inhalers. More recently, single-inhaler triple therapies have been developed, meaning patients can take all three different medications at the same time via one single inhaler. This study assessed the characteristics of patients who were already receiving triple therapy, or who started triple therapy (either via multiple inhalers or a single inhaler), in Germany between January 2015 and December 2019. In total, 18,630 patients who were already receiving triple therapy during the study period, and 2932 patients who newly started using triple therapy were included. The study reported that more than two-thirds of included patients had experienced at least one flare-up of COPD symptoms in the 2 years before starting triple therapy. Most patients had also received another therapy for COPD before starting triple therapy. A small proportion of patients started taking triple therapy after receiving no other therapy for COPD in the previous 2 years. The results of the study suggest that triple therapy for COPD in Germany is most often used in accordance with recommendations (patients already receiving therapy and experiencing repeated symptom flare-ups).


Subject(s)
Adrenergic beta-2 Receptor Agonists , Bronchodilator Agents , Drug Combinations , Glycopyrrolate , Muscarinic Antagonists , Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive , Humans , Male , Pulmonary Disease, Chronic Obstructive/drug therapy , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/physiopathology , Female , Retrospective Studies , Germany , Aged , Administration, Inhalation , Middle Aged , Muscarinic Antagonists/administration & dosage , Muscarinic Antagonists/adverse effects , Bronchodilator Agents/administration & dosage , Bronchodilator Agents/adverse effects , Adrenergic beta-2 Receptor Agonists/administration & dosage , Adrenergic beta-2 Receptor Agonists/adverse effects , Glycopyrrolate/administration & dosage , Glycopyrrolate/adverse effects , Chlorobenzenes/administration & dosage , Chlorobenzenes/adverse effects , Quinuclidines/administration & dosage , Quinuclidines/adverse effects , Treatment Outcome , Benzyl Alcohols/administration & dosage , Benzyl Alcohols/adverse effects , Beclomethasone/administration & dosage , Beclomethasone/adverse effects , Formoterol Fumarate/administration & dosage , Drug Therapy, Combination , Time Factors , Aged, 80 and over
12.
BMJ Open Respir Res ; 11(1)2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38626929

ABSTRACT

BACKGROUND: Errors using inhaled delivery systems for COPD are common and it is assumed that these lead to worse clinical outcomes. Previous systematic reviews have included patients with both asthma and COPD and much of the evidence related to asthma. More studies in COPD have now been published. Through systematic review, the relationship between errors using inhalers and clinical outcomes in COPD, including the importance of specific errors, was assessed.MethodsElectronic databases were searched on 27 October 2023 to identify cohort, case-control or randomised controlled studies, which included patients with COPD, an objective assessment of inhaler errors and data on at least one outcome of interest (forced expiratory volume in 1 s, (FEV1), dyspnoea, health status and exacerbations). Study quality was assessed using the Newcastle and Ottawa scales. A narrative synthesis of the results was performed as there was insufficient detail in the publications to allow quantitative synthesis. There was no funding for the review. RESULTS: 19 publications were included (7 cohort and 12 case-control) reporting outcomes on 6487 patients. 15 were considered low quality, and most were confounded by the absence of adherence data. There was weak evidence that lower error rates are associated with better FEV1, symptoms and health status and fewer exacerbations. Only one considered the effects of individual errors and found that only some were related to worse outcomes. CONCLUSION: Evidence about the importance of specific errors using inhalers and outcomes would optimise the education and training of patients with COPD. Prospective studies, including objective monitoring of inhalation technique and adherence, are needed. PROSPERO REGISTRATION NUMBER: CRD42023393120.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/drug therapy , Prospective Studies , Nebulizers and Vaporizers , Dyspnea
13.
Article in English | MEDLINE | ID: mdl-38562440

ABSTRACT

Objective: To comparison of the application of Vibrating Mesh Nebulizer and Jet Nebulizer in chronic obstructive pulmonary disease (COPD). Research Methods: This systematic review and meta-analysis was conducted following the Preferred Reporting Items for Systematic Review and Meta-analyses (PRISMA) statements. The primary outcome measures analyzed included: The amount of inhaler in the urine sample at 30 minutes after inhalation therapy (USAL0.5), The total amount of inhaler in urine sample within 24 hours (USAL24), Aerosol emitted, Forced expiratory volume in 1 second (FEV1), Forced vital capacity (FVC). Results: Ten studies were included with a total of 314 study participants, including 157 subjects in the VMN group and 157 subjects in the JN group. The data analysis results of USAL0.5, MD (1.88 [95% CI, 0.95 to 2.81], P = 0.000), showed a statistically significant difference. USAL24, MD (1.61 [95% CI, 1.14 to 2.09], P = 0.000), showed a statistically significant difference. The results of aerosol emitted showed a statistically significant difference in MD (3.44 [95% CI, 2.84 to 4.04], P = 0.000). The results of FEV1 showed MD (0.05 [95% CI, -0.24 to 0.35], P=0.716), the results were not statistically significant. The results of FVC showed MD (0.11 [95% CI, -0.18 to 0.41], P=0.459), the results were not statistically significant. It suggests that VMN is better than JN and provides higher aerosols, but there is no difference in improving lung function between them. Conclusion: VMN is significantly better than JN in terms of drug delivery and utilization in the treatment of patients with COPD. However, in the future use of nebulizers, it is important to select a matching nebulizer based on a combination of factors such as mechanism of action of the nebulizer, disease type and comorbidities, ventilation strategies and modes, drug formulations, as well as cost-effectiveness, in order to achieve the ideal treatment of COPD.


Subject(s)
Bronchodilator Agents , Pulmonary Disease, Chronic Obstructive , Humans , Administration, Inhalation , Albuterol , Bronchodilator Agents/adverse effects , Drug Delivery Systems , Equipment Design , Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive/diagnosis , Pulmonary Disease, Chronic Obstructive/drug therapy , Respiratory Aerosols and Droplets
14.
Anal Chem ; 96(18): 7187-7193, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38671557

ABSTRACT

Despite the significant importance of blood lithium (Li) detection in the treatment of bipolar disorder (BD), its point-of-care testing (POCT) remains a great challenge due to tedious sample preparation and the use of large-footprint atomic spectrometers. Herein, a system coupling dried blood spots (DBS) with a point discharge optical emission spectrometer equipped with a miniaturized ultrasonic nebulizer (MUN-µPD-OES) was developed for POCT of blood Li. Three microliters of whole blood were used to prepare a dried blood spot on a piece of filter paper to which 10 µL of eluent (1% (v/v) formic acid and 0.05% (v/v) Triton-X) was added. Subsequently, the paper was placed onto the vibrating steel membrane of the ultrasonic nebulizer and powered on to generate aerosol. The aerosol was directly introduced to the µPD-OES for quantification of Li by monitoring its atomic emission line at 670.8 nm. The proposed method minimized matrix interference caused by high levels of salts and protein. It is worth noting that the MUN suitably matches the needs of DBS sampling and can provide aerosolized introduction of Li into the assembled µPD-OES, thus eliminating all tedious sample preparation and the need for a commercial atomic spectrometer. Calibration response is linear in the therapeutic range and a limit of detection (LOD) of 1.3 µg L-1 is well below the Li minimum therapeutic concentration (2800 µg L-1). Li in mouse blood was successfully detected in real-time using MUN-µPD-OES after intraperitoneal injection of lithium carbonate, confirming that the system holds great potential for POCT of blood Li for patients with BD.


Subject(s)
Dried Blood Spot Testing , Lithium , Point-of-Care Testing , Lithium/blood , Humans , Dried Blood Spot Testing/instrumentation , Dried Blood Spot Testing/methods , Animals , Mice , Nebulizers and Vaporizers , Miniaturization , Ultrasonics , Limit of Detection
15.
J Hazard Mater ; 471: 134365, 2024 Jun 05.
Article in English | MEDLINE | ID: mdl-38669926

ABSTRACT

The disinfection of fabrics is crucial in preventing the spread of infectious diseases caused by pathogenic microorganisms to maintain public health. A previous study proved that plasma-activated nebulized mist (PANM) could effectively inactivate microorganisms both in aerosol and attached to the surface. In this study, the PANM driven by different plasma gases were employed to inactivate microorganisms on diverse fabrics. The PANM could efficiently inactivate a variety of microorganisms, including bacteria, fungi, and viruses, contaminating different fabrics, and even across covering layers of different fabrics. The mites residing on the cotton fabrics both uncovered and covered with various types of fabrics were also effectively inactivated by the PANM. After 30 times repeated treatments of the PANM, notable changes were observed in the color of several fabrics while the structural integrity and mechanical strength of the fabrics were unaffected and maintained similarly to the untreated fabrics with slight changes in elemental composition. Additionally, only trace amounts of nitrate remained in the fabrics after the PANM treatment. Therefore, the PANM treatment supplied an efficient, broad-spectrum, and environmentally friendly strategy for industrial and household disinfection of fabrics.


Subject(s)
Plasma Gases , Textiles , Plasma Gases/pharmacology , Animals , Disinfection/methods , Bacteria/drug effects , Fungi/drug effects , Nebulizers and Vaporizers , Viruses/drug effects
16.
Swiss Med Wkly ; 154: 3394, 2024 Apr 04.
Article in English | MEDLINE | ID: mdl-38579300

ABSTRACT

AIMS OF THE STUDY: Misuse of inhalers during chronic obstructive pulmonary disease (COPD) treatment is common and may result from errors in inhalation technique or insufficient peak inspiratory flow (PIF). We aimed to evaluate the impact of an in-hospital intervention to reduce inhaler misuse at hospital discharge among patients with COPD. METHODS: We conducted a monocentric, non-randomised intervention study to compare the proportion of misused inhalers at hospital discharge by patients with COPD between a group with standard care and a group receiving an in-hospital intervention. The control group successively included all patients hospitalised between March and June 2022, and the intervention group included patients hospitalised between August and December 2022. The intervention consisted of (a) an evaluation of inhalation technique and PIF at admission, (b) the provision of a written guide to assist in the selection of an inhaler, and (c) therapeutic education. The primary outcome was the proportion of misused inhalers, defined as an inhaler used with a critical error and/or insufficient PIF, at hospital discharge. The primary outcome was assessed by observing inhalation technique and measuring PIF using the In-Check DIAL G16® . RESULTS: The study included 93 patients: 46 in the control group and 47 in the intervention group. Mean age was 70.5 years (SD 10.9 years), 56 patients (60.2%) were men, and 57 patients (62%) were hospitalised for a COPD exacerbation. Patients used an average of 1.9 inhalers at hospital discharge; 98 inhalers were assessed in the control group and 81 in the intervention group. The proportion of misused inhalers at discharge was 61.2% in the control group and 21.0% in the intervention group (absolute risk reduction 40.2% [95% CI 25.5-55.0]; p <0.01). In the intervention group, the proportion of inhalers used with at least one critical error was reduced by 38.6% (95% CI 24.3-52.3%) and that of inhalers used with insufficient PIF by 13.9% (95% CI 4.2-23.6%). CONCLUSIONS: An in-hospital intervention was associated with a reduction in the proportion of misused inhalers at hospital discharge. This intervention should be considered for hospitalised patients with COPD. The trial was registered with ClinicalTrials.gov (NCT05207631).


Subject(s)
Patient Discharge , Pulmonary Disease, Chronic Obstructive , Aged , Female , Humans , Male , Administration, Inhalation , Hospitalization , Hospitals , Nebulizers and Vaporizers , Pulmonary Disease, Chronic Obstructive/drug therapy , Aged, 80 and over
17.
Sci Rep ; 14(1): 8953, 2024 04 18.
Article in English | MEDLINE | ID: mdl-38637547

ABSTRACT

Although oxytocin (OT) plays a role in bonding between heterospecifics and conspecifics, the effects of OT on the formation of such interspecific social behavior have only been investigated between humans and dogs (Canis familiaris). In this study, for comparative evaluation of the effects of OT between dog-human and cat-human social interaction, we investigated the effects of exogenous OT on the behavior of domestic cats (Felis silvestris catus) toward humans. We intranasally administered OT or saline to 30 cats using a nebulizer and recorded their behavior (gaze, touch, vocalization, and proximity). The results showed an interaction between the administration condition and sex for gaze duration. Post hoc analyses revealed a significant increase in gaze in the OT condition in male cats but not in females. There were no significant differences in gaze toward owners and strangers in any condition or sex. The male-specific OT-mediated increase in gaze toward humans observed in this study differs from previous research on dogs wherein such effects were observed only in females. These findings suggest an overall effect of exogenous OT on cats' social relationship with humans as well as the possibility of different mechanisms between cat-human and dog-human relationships.


Subject(s)
Oxytocin , Social Behavior , Female , Humans , Cats , Animals , Male , Dogs , Oxytocin/pharmacology , Interpersonal Relations , Social Interaction , Nebulizers and Vaporizers
18.
J Clin Anesth ; 95: 111461, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38604048

ABSTRACT

BACKGROUND: There is a search for an ideal agent to facilitate awake fiberoptic intubation (AFOI). Dexmedetomidine is a selective α2 agonist which can be administered through intravenous, intramuscular, buccal, intranasal & inhalational routes. It provides good intubation conditions without oxygen desaturation but may cause hypotension and bradycardia when administered intravenously. Hence, alternative routes of administering dexmedetomidine which may improve its safety profile are worth exploring. METHODS: In this randomised, controlled, double-blind trial, 46 ASA I/II adult participants scheduled for elective ENT surgery were randomly allocated to Group ND (Nebulised Dexmedetomidine) (n = 23) to receive nebulisation with dexmedetomidine 1µg.kg-1 and Group ID (Intravenous Dexmedetomidine) (n = 23) to receive intravenous dexmedetomidine 1µg.kg-1 before AFOI. All the patients received injection midazolam 1 mg i.v. as premedication before anaesthesia was initiated. The primary outcome was the cough score. The secondary outcomes were the RSS, SAYGO boluses, post-intubation score, hemodynamic parameters, recall of the procedure, patient satisfaction score and any side effects. RESULTS: The cough score was significantly lower in nebulized group (2.43 ± 0.992 vs 3.52 ± 1.082) with p = 0.001. RSS(3.30 ± 0.926 vs 4.22 ± 1.126; p = 0.004), number of SAYGO boluses required (2.74 ± 0.864 vs 3.57 ± 1.161; p = 0.009) & the post intubation score (1.48 ± 0.593 vs 2.17 ± 0.778; p = 0.001) were also significantly lower in nebulized group. CONCLUSIONS: Nebulisation with dexmedetomidine results in desirable degree of sedation and better tolerance of the procedure with adequate attenuation of the haemodynamic responses to intubation.


Subject(s)
Dexmedetomidine , Fiber Optic Technology , Hypnotics and Sedatives , Intubation, Intratracheal , Nebulizers and Vaporizers , Humans , Dexmedetomidine/administration & dosage , Dexmedetomidine/adverse effects , Intubation, Intratracheal/adverse effects , Intubation, Intratracheal/methods , Double-Blind Method , Male , Female , Adult , Middle Aged , Hypnotics and Sedatives/administration & dosage , Hypnotics and Sedatives/adverse effects , Patient Satisfaction , Administration, Inhalation , Wakefulness/drug effects , Young Adult , Administration, Intravenous
19.
Biomater Adv ; 159: 213823, 2024 May.
Article in English | MEDLINE | ID: mdl-38460353

ABSTRACT

Lung cancer, one of the most common causes of high mortality worldwide, still lacks appropriate and convenient treatment options. Photodynamic therapy (PDT) has shown promising results against cancer, especially in recent years. However, pulmonary drug delivery of the predominantly hydrophobic photosensitizers still represents a significant obstacle. Nebulizing DPPC/Cholesterol liposomes loaded with the photosensitizer curcumin via a vibrating mesh nebulizer might overcome current restrictions. In this study, the liposomes were prepared by conventional thin-film hydration and two other methods based on dual centrifugation. The liposomes' physicochemical properties were determined before and after nebulization, showing that liposomes do not undergo any changes. However, morphological characterization of the differently prepared liposomes revealed structural differences between the methods in terms of lamellarity. Internalization of curcumin in lung adenocarcinoma (A549) cells was visualized and quantified. The generation of reactive oxygen species because of the photoreaction was also proven. The photodynamic efficacy of the liposomal formulations was tested against A549 cells. They revealed different phototoxic responses at different radiant exposures. Furthermore, the photodynamic efficacy was investigated after nebulizing curcumin-loaded liposomes onto xenografted tumors on the CAM, followed by irradiation, and evaluated using positron emission tomography/computed tomography and histological analysis. A decrease in tumor metabolism could be observed. Based on the efficacy of curcumin-loaded liposomes in 2D and 3D models, liposomes, especially with prior film formation, can be considered a promising approach for PDT against lung cancer.


Subject(s)
Curcumin , Lung Neoplasms , Humans , Liposomes/therapeutic use , Curcumin/pharmacology , Curcumin/therapeutic use , Drug Delivery Systems , Nebulizers and Vaporizers , Photosensitizing Agents/therapeutic use , Lung Neoplasms/drug therapy , Lung Neoplasms/pathology
20.
Mol Pharm ; 21(4): 1848-1860, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38466817

ABSTRACT

Liposomal carrier systems have emerged as a promising technology for pulmonary drug delivery. This study focuses on two selected liposomal systems, namely, dipalmitoylphosphatidylcholine stabilized by phosphatidic acid and cholesterol (DPPC-PA-Chol) and dipalmitoylphosphatidylcholine stabilized by polyethylene glycol and cholesterol (DPPC-PEG-Chol). First, the research investigates the stability of these liposomal systems during the atomization process using different kinds of nebulizers (air-jet, vibrating mesh, and ultrasonic). The study further explores the aerodynamic particle size distribution of the aerosol generated by the nebulizers. The nebulizer that demonstrated optimal stability and particle size was selected for more detailed investigation, including Andersen cascade impactor measurements, an assessment of the influence of flow rate and breathing profiles on aerosol particle size, and an in vitro deposition study on a realistic replica of the upper airways. The most suitable combination of a nebulizer and liposomal system was DPPC-PA-Chol nebulized by a Pari LC Sprint Star in terms of stability and particle size. The influence of the inspiration flow rate on the particle size was not very strong but was not negligible either (decrease of Dv50 by 1.34 µm with the flow rate increase from 8 to 60 L/min). A similar effect was observed for realistic transient inhalation. According to the in vitro deposition measurement, approximately 90% and 70% of the aerosol penetrated downstream of the trachea using the stationary flow rate and the realistic breathing profile, respectively. These data provide an image of the potential applicability of liposomal carrier systems for nebulizer therapy. Regional lung drug deposition is patient-specific; therefore, deposition results might vary for different airway geometries. However, deposition measurement with realistic boundary conditions (airway geometry, breathing profile) brings a more realistic image of the drug delivery by the selected technology. Our results show how much data from cascade impactor testing or estimates from the fine fraction concept differ from those of a more realistic case.


Subject(s)
Bronchodilator Agents , Trachea , Humans , 1,2-Dipalmitoylphosphatidylcholine , Nebulizers and Vaporizers , Liposomes , Aerosols , Administration, Inhalation , Drug Delivery Systems , Cholesterol , Particle Size , Equipment Design
SELECTION OF CITATIONS
SEARCH DETAIL
...