J Cataract Refract Surg ; 50(10): 1000-1005, 2024 Oct 01.
Article in English | MEDLINE | ID: mdl-38787622

ABSTRACT

PURPOSE: To evaluate the stability of the postoperative vault of the implantable phakic contact lens (IPCL) 5 years after implantation. SETTING: Clínica de Ojos Dr. Nano, Olivos, Buenos Aires, Argentina. DESIGN: Retrospective case-series study. METHODS: Myopic patients operated with the IPCL for spherical correction in which preoperative data were compared with different scenarios of postoperative vault at 1, 3, and 5 years postoperatively. The main parameter to be evaluated was the vault obtained 5 years postoperatively. RESULTS: 140 eyes of 72 patients, aged 31.9 ± 2.8 years (21 to 50), were included. Most of the eyes (78.6%) obtained a vault between 250 µm and 750 µm, while in 15% of the eyes, it was less than 250 µm, and 6.4% were greater than 750 µm. The vault evaluated 1, 3, and 5 years postoperatively remained stable. Subcapsular cataracts were detected in 2 eyes, with vault <250 µm. A total of 50 eyes (35.7%) had cysts in the sulcus (5 cases in the group of eyes with vault >750 µm). No changes were detected in relation to intraocular pressure or endothelial cell count. CONCLUSIONS: In eyes implanted with the IPCL over 5 years, it was observed that the vault remained stable over time. The proportion of eyes with cysts was higher in eyes with vaults larger than 750 µm.


Subject(s)
Myopia , Phakic Intraocular Lenses , Visual Acuity , Humans , Retrospective Studies , Adult , Myopia/surgery , Myopia/physiopathology , Middle Aged , Young Adult , Visual Acuity/physiology , Female , Male , Follow-Up Studies , Refraction, Ocular/physiology , Intraocular Pressure/physiology , Postoperative Period , Lens Implantation, Intraocular
3.
Rev. cuba. oftalmol ; 36(3)sept. 2023.
Article in Spanish | LILACS, CUMED | ID: biblio-1550942

ABSTRACT

Objetivo: Determinar las modificaciones biométricas en pacientes miopes con implante de la lente fáquica ACRIOL 128. Métodos: Se realizó un estudio transversal con 31 ojos (17 pacientes) con alta miopía tratados con implante de lente fáquica ACRIOL 128, entre septiembre 2016 y febrero 2019, los cuales tenían mediciones biométricas preoperatorias con el sistema IOL Master 3.0.2 y estabilidad refractiva posoperatoria (≤ 0,5 dioptrías) después de los tres meses del implante. Se les efectuaron las mediciones posoperatorias con el propio IOL Master 3.0.2 en modo lente fáquica y con el sistema Scheimpflug Pentacam AXL para compararlas, mediante la prueba t para datos pareados, con una significación del 95 por ciento. Resultados: La edad promedio fue de 29,82 ± 5,99 años, el 82,4 por ciento del sexo femenino. El equivalente esférico preoperatorio medio fue de -12,00 ± 4,10 dioptrías. La diferencia de longitud axial y profundidad de la cámara anterior en milímetros entre el pre- y posoperatorio fue significativa con IOL Master 3.0.2 (0,13 ± 0,33 y -0,08 ± 0,17) y Pentacam AXL (0,12 ± 0,32 y -0,10 ± 0,24), respectivamente. Sin embargo, las posoperatorias entre ambos equipos no fueron significativas (p>0,05) para estas variables, pero sí para las queratometrías. Conclusiones: El implante de la lente fáquica ACRIOL 128 modifica la medición de la longitud axial y la profundidad de la cámara anterior. El IOL Master 3.0.2 y el Pentacam AXL ofrecen mediciones de longitud axial y profundidad de cámara anterior posoperatorias similares, no así para las queratometrías(AU)


Objective: To determine the biometric modifications in myopic patients with ACRIOL 128 phakic lens implantation. Methods: A cross-sectional study was performed on 31 eyes (17 patients) with high myopia treated with ACRIOL 128 phakic lens implant, between September 2016 and February 2019, which had preoperative biometric measurements with the IOL Master 3.0.2 system and postoperative refractive stability (≤ 0.5 diopters) after three months of implantation. Postoperative measurements were performed with the IOL Master 3.0.2 in phakic lens mode and with the Scheimpflug Pentacam AXL system for comparison, using the t-test for paired data, with 95% significance. Results: The average age was 29.82 ± 5.99 years, 82.4por ciento female. The mean preoperative spherical equivalent was -12.00 ± 4.10 diopters. The difference in axial length and anterior chamber depth in millimeters between pre- and postoperative was significant with IOL Master 3.0.2 (0.13 ± 0,33 and -0.08 ± 0.17) and Pentacam AXL (0.12 ± 0.32 and -0.10 ± 0.24), respectively. However, postoperative between the two teams were not significant (p > 0.05) for these variables but significant for keratometries. Conclusions: Implantation of the ACRIOL 128 phakic lens modifies the measurement of axial length and anterior chamber depth. The IOL Master 3.0.2 and Pentacam AXL provide similar postoperative axial length and anterior chamber depth measurements, but not for keratometries(AU)


Subject(s)
Humans , Biometry/methods , Phakic Intraocular Lenses
4.
In. Cárdenas Díaz, Taimi. Óptica y optometría. Principios y aplicación clínica. Volumen 3. La Habana, Editorial Ciencias Médicas, 2023. , ilus.
Monography in Spanish | CUMED | ID: cum-79226
5.
Int Ophthalmol ; 43(2): 357-358, 2023 Feb.
Article in English | MEDLINE | ID: mdl-35916990

ABSTRACT

A correction about phakic intraocular lens power calculation process, as it was stated by Li, Song & Song, is provided. It is explained that this calculation is based on the Van der Heijde formula and not on biometric formulas. A comment about the mechanisms of late endothelial cell loss following phakic intraocular lenses is done.


Subject(s)
Lenses, Intraocular , Myopia , Phakic Intraocular Lenses , Humans , Lens Implantation, Intraocular , Endothelial Cells , Myopia/surgery , Biometry , Lenses, Intraocular/adverse effects
6.
In. Hernández Silva, Juan Raúl. Facoemulsificación. La Habana, Editorial Ciencias Médicas, 2022. , ilus.
Monography in Spanish | CUMED | ID: cum-78475
7.
Rev. cuba. invest. bioméd ; 40(4)dic. 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1408581

ABSTRACT

Objetivo: Determinar la seguridad de los lentes fáquicos ACR-128 en la corrección de la alta miopía tras un año de implantados. Método: Se realizó un estudio transversal en 67 ojos de 36 pacientes con miopía corregida con lente fáquica ACR-128 (31 con ambos ojos y 5 con un solo ojo). Se determinó preoperatorio y posoperatorio: tensión ocular, pérdida celular endotelial según conteo, coeficiente de variación celular y hexagonalidad. Además de complicaciones posoperatorias y posición del lente respecto a endotelio y cristalino. El análisis estadístico se realizó con la prueba T para datos pareados, con una significación del 95 por ciento. Resultados: Edad media 28,06 ± 6,14 (25 mujeres y 11 hombres). Las complicaciones inmediatas fueron hipotonía OD: 1 (3,03 por ciento), OI: 1 (2,94 por ciento). La irregularidad de la pupila se presentó OD: 1 (3,03 por ciento), OI: 1 (2,94 por ciento) mediata y OD: 1 (3,03 por ciento), OI: 2 (5.88 por ciento) tardía. Tensión ocular promedio total preoperatorio 14,09 ± 2,51 y posoperatorio 14,22 ± 2,64 (p = 0,90). El conteo celular preoperatorio 2667,27 ± 228,72 y posoperatorio 2591,96 ± 301,21, con 2,94 por ciento pérdida endotelial total 75,31 ± 237,41 (p = 0,06). No hubo diferencias en el coeficiente de variación (p = 0,60) ni la hexagonalidad (p = 0,57). Posición del lente respecto al endotelio 2,09 mm y al cristalino 1,08 mm. Conclusiones: El implante de lente fáquica ACR-128 en la corrección de la alta miopía es un tratamiento seguro al no existir complicaciones posquirúrgico ni modificaciones en la tensión ocular y en el endotelio corneal tras un año del implante(AU)


Objective: Determine the safety of ACR-128 phakic lenses for high myopia correction one year after implantation. Method: A cross-sectional study was conducted of 67 eyes of 36 patients with myopia corrected with ACR-128 phakic lens implants (31 in both eyes and 5 in one eye). Pre- and postoperative determination was made of ocular tension, endothelial cell loss by count, cell variation coefficient and hexagonality, as well as of postoperative complications and lens position with respect to the endothelium and the crystalline lens. Statistical analysis was based on the paired T-test with a significance level of 95 percent Results: Mean age was 28.06 ± 6.14 (25 women and 11 men). An immediate complication was hypotonia: RE: 1 (3.03 percent), LE: 1 (2.94 percent). Pupil irregularity was mediate: RE: 1 (3.03 percent), LE: 1 (2.94 percent) and late: RE: 1 (3.03 percent), LE: 2 (5.88 percent). Total average ocular tension was 14.09 ± 2.51 preoperative and 14.22 ± 2.64 postoperative (p = 0.90). Cell count was 2667.27 ± 228.72 preoperative and 2591.96 ± 301.21 postoperative, with 2.94 percent total endothelial loss 75.31 ± 237.41 (p = 0.06). Differences were not found in the variation coefficient (p = 0.60) or in hexagonality (p = 0.57). Lens position was 2.09 mm with respect to the endothelium and 1.08 mm with respect to the crystalline lens. Conclusions: ACR-128 phakic lens implantation for high myopia correction is a safe procedure with no postoperative complications or modifications in ocular tension or the corneal endothelium after one year's follow-up(AU)


Subject(s)
Humans , Male , Female , Safety , Phakic Intraocular Lenses , Myopia/surgery , Myopia/complications , Cross-Sectional Studies
8.
Rev. cuba. oftalmol ; 34(3): e974, 2021. graf
Article in Spanish | LILACS, CUMED | ID: biblio-1352034

ABSTRACT

El implante de una lente intraocular fáquica puede resultar una opción lógica para los pacientes sumamente miopes que buscan liberarse de las gafas y de los lentes de contacto. Esta es una alternativa para corregir los grados de miopía extremos, y se diseñaron para permanecer dentro del ojo por muchos años. Con el cursar del tiempo, fisiológicamente comienza a opacarse el cristalino. Ante la necesidad de removerlo y de calcular una lente de potencia adecuada para el saco capsular y así conseguir la emetropía, surge un nuevo reto. El cálculo inexacto de la potencia dióptrica de la lente a implantar en la intervención quirúrgica es un problema y con él aparece la sorpresa refractiva; de ahí el objetivo de presentar con este caso la causa más frecuente de sorpresa refractiva tras la cirugía de catarata en un paciente miope con lente fáquica implantada. Se destaca la importancia de la longitud axil, sobre todo si esta se modifica después del implante de la lente fáquica para el correcto cálculo de la lente a implantar, así como el método ideal para su obtención: la interferometría óptica, sin olvidar la historia clínica previa al implante de la lente fáquica(AU)


Phakic intraocular lens implantation may be a logical option for extremely myopic patients who wish to get rid of their eyeglasses and contact lenses. This alternative was developed to correct extremely high degrees of myopia and remain inside the eye for many years. However, with the passing of time and due to physiological processes, the crystalline lens tends to become opaque. A new challenge is posed by the need to remove it and select a lens with an optical power appropriate to the capsular sac, thus achieving emmetropia. Inaccurate calculation of the dioptric power of the lens to be implanted in the surgical intervention is a problem leading to refractive surprise. Hence the interest in presenting a case illustrating the most common cause of refractive surprise after cataract surgery in a myopic patient with a phakic lens implant. The importance of axial length is highlighted, particularly whether it is modified after phakic lens implantation for accurate calculation of the lens to be implanted and the ideal method to obtain it: optical interferometry, without disregarding the medical record data preceding the phakic lens implantation(AU)


Subject(s)
Humans , Female , Middle Aged , Surgical Procedures, Operative/methods , Cataract Extraction/methods , Phakic Intraocular Lenses/adverse effects , Interferometry/methods , Medical Records , Myopia/etiology
9.
Rev. cuba. invest. bioméd ; 40(3)sept. 2021. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1408567

ABSTRACT

Introducción: El implante de una lente intraocular fáquico para corregir defectos de la refracción presenta una serie de ventajas respecto a otras técnicas como la cirugía refractiva corneal o la extracción de cristalino transparente. Objetivo: Describir los cambios en la calidad de vida relacionados con la función visual en la corrección de alta miopía con implante de lente fáquico ACR-128. Métodos: Se realizó un estudio descriptivo, longitudinal y prospectivo con análisis estadístico separado por ojos. La muestra total se correspondió con 91 ojos (46 derechos y 45 izquierdos) de 49 pacientes a los que se les implantó lente fáquico ACR-128 para la corrección de miopía. Mediante el test de Pelli-Robson se determinó la sensibilidad al contraste binocular a varias frecuencias espaciales y se les aplicó el cuestionario NEI-VFQ-25 antes de la cirugía (pretest) y a los tres meses de realizada la misma (postest). El análisis estadístico se realizó con la prueba T para datos pareados, con una significación del 95 por ciento. Resultados: Edad media 28,73 ± 5,85 años. Predominio del sexo femenino (71,43 por ciento). Hubo diferencias significativas en todas las frecuencias espaciales de la sensibilidad al contraste binocular entre el pre- y posoperatorio (p < 0,01). Al comparar el pretest y el postest (valoración retrospectiva de la calidad de vida prequirúrgica) no se encontraron diferencias significativas, lo que indicó que no hubo recalibración y que las diferencias con el postest que fueron significativas corroboren el verdadero cambio en la calidad de vida de estos pacientes tras la cirugía. Conclusiones: El implante de lentes fáquicos ACR-128 para la corrección de la alta miopía mejora la calidad de vida relacionada con la función visual sin cambios en su percepción antes y después de la cirugía(AU)


Introduction: Phakic intraocular lens implantation to correct refraction defects has a number of advantages with respect to techniques such as corneal refractive surgery or clear lens extraction. Objective: Describe the changes in vision-related quality of life resulting from high myopia correction by ACR-128 phakic lens implantation. Methods: A prospective longitudinal descriptive study was conducted with independent statistical analysis for each eye. The total sample was 91 eyes (46 right and 45 left) of 49 patients undergoing ACR-128 phakic lens implantation for myopia correction. The Pelli-Robson test was used to determine binocular contrast sensitivity at various spatial frequencies, and the NEI VFQ-25 questionnaire was applied before surgery (pre-test) and three months after surgery (post-test). Statistical analysis was based on the paired T-test with a significance level of 95 percent. Results: Mean age was 28.73 ± 5.85 years. Female sex prevailed (71.43 percent). Significant differences were found in all the spatial frequencies of binocular contrast sensitivity between the pre- and postoperative periods (p < 0.01). Comparison of pre- and post-test results (retrospective assessment of presurgical quality of life) did not find any significant differences, indicating that there was no recalibration. Significant differences with respect to the post-test confirm the actual change in these patients' quality of life after surgery. Conclusions: ACR-128 phakic lens implantation for high myopia correction improves vision-related quality of life without changes in its perception before and after surgery(AU)


Subject(s)
Humans , Male , Female , Quality of Life , Vision, Ocular , Phakic Intraocular Lenses , Myopia/surgery , Epidemiology, Descriptive , Prospective Studies , Longitudinal Studies
10.
Rom J Ophthalmol ; 65(2): 163-170, 2021.
Article in English | MEDLINE | ID: mdl-34179582

ABSTRACT

Objective: Refractive management in keratoconus is challenging. Although some kinds of phakic intraocular lenses have been studied in keratoconus so far, no study evaluated the results of EyeCryl Phakic Toric intraocular lenses in this kind of patients. Materials and Methods: This is a retrospective chart review study, including all keratoconus patients implanted with an EyeCryl Phakic Toric intraocular lens in at least one of their eyes by an experienced cornea surgeon in Colombia. Follow-up to 6 months after surgery was also included. Results: A total of 20 eyes of 14 patients were included, with an average age of 29.3 ± 4.2 years. Spherical equivalent improved from a pre-surgical value of -10.31 D to +0.09 D at 6 months. 65% of the patients improved at least one line in the best-corrected distance visual acuity. At 6 months, 70% of the patients were within ± 0.50 D of spherical equivalent emmetropia. No complications occurred in any of the patients. Conclusion: EyeCryl Phakic intraocular lenses are an excellent option in keratoconus patients with high refractive error. Abbreviations: KC = Keratoconus, P-IOL = phakic intraocular lenses, ICL = Implantable Collamer Lens, WTW = White to White, SD = standard deviation, ANOVA = an analysis of variance, UDVA = monocular uncorrected distance visual acuity, CDVA = corrected distance visual acuity.


Subject(s)
Astigmatism , Keratoconus , Phakic Intraocular Lenses , Adult , Astigmatism/surgery , Follow-Up Studies , Humans , Keratoconus/surgery , Lens Implantation, Intraocular , Retrospective Studies
11.
Rev. bras. oftalmol ; 80(3): e0012, 2021. tab, graf
Article in Portuguese | LILACS | ID: biblio-1280123

ABSTRACT

RESUMO O implante de lentes intraoculares fácicas com finalidade refrativa é uma alternativa cirúrgica eletiva segura e eficiente. Essa opção deve ser considerada de forma eletiva para tratar ametropias, nos casos em que as cirurgias de correção visual refrativa a laser na córnea apresentam maior risco de complicações, seja por características da córnea ou pela magnitude da ametropia. Este artigo traz uma revisão prospectiva das lentes fácicas disponíveis no mercado brasileiro em 2020 e suas características.


ABSTRACT Implantation of phakic intraocular lenses for refractive purpose is a safe and efficient elective surgical alternative. This option should be considered to electively treat ametropia when laser corneal refractive surgery has higher risk of complications, either due to corneal characteristics or the magnitude of ametropia. This article provides a prospective review of the phakic lenses available in the Brazilian market in 2020 and their characteristics.


Subject(s)
Astigmatism/surgery , Refractive Surgical Procedures , Phakic Intraocular Lenses , Myopia/surgery
12.
Rev. cuba. oftalmol ; 33(3): e897, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1139099

ABSTRACT

RESUMEN La cirugía refractiva corneal es una buena opción para corregir el defecto refractivo de los pacientes y lograr una buena visión sin el uso de espejuelos o lentes de contacto; pero cuando no es posible, las lentes fáquicas constituyen una elección viable, especialmente en pacientes jóvenes que mantienen la acomodación. Se presenta el caso de una paciente con antecedentes de implante de lente fáquica desde hacía 13 años, quien acudió al Instituto Cubano de Oftalmología "Ramón Pando Ferrer" por disminución de la visión en ambos ojos. Se destaca la importancia en la obtención de las medidas biométricas, especialmente la longitud axil, si esta se modifica después del implante de la lente fáquica para el correcto cálculo de la lente a implantar y la obtención del buen resultado refractivo. La interferometría óptica es el mejor modo de obtener estas medidas y la longitud axil no parece modificarse con la presencia de una lente fáquica(AU)


ABSTRACT Corneal refractive surgery is a good option to correct the refractive defect and achieve good vision without the use of eyeglasses or contact lenses. When it is not possible, phakic lenses are a viable choice, particularly in young patients who maintain accommodation. A case is presented of a female patient with an antecedent of phakic lens implantation 13 years before who presents at Ramón Pando Ferrer Cuban Institute of Ophthalmology with vision reduction in both eyes. Mention should be made of the importance of obtaining biometric measurements, especially of the axial length, if it changes after phakic lens implantation, for accurate calculation of the lens to be implanted and the achievement of a good refractive result. Optical interferometry is the best way to obtain those measurements, and axial length does not seem to change with the presence of a phakic lens(AU)


Subject(s)
Humans , Female , Middle Aged , Cataract Extraction/methods , Refractive Surgical Procedures , Phakic Intraocular Lenses/adverse effects , Interferometry/methods
13.
J Cataract Refract Surg ; 46(1): 125-137, 2020 01.
Article in English | MEDLINE | ID: mdl-32050242

ABSTRACT

The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects. The iris-fixated phakic intraocular lens (pIOL) has been available for over 25 years. To provide a clear picture of outcomes and risks, for this systematic review and meta-analysis, the literature was searched for reports on middle- and long-term effects of iris-fixated pIOLs on myopic and hyperopic eyes with a follow-up of at least 2 to 4 years. Visual and refractive results after implantation for correction of myopia are positive and the complication rate is low. Endothelial cell loss appears to be at an acceptable rate, although the range of endothelial cell change is too wide to draw firm conclusions. Care should be taken when considering an iris-fixated pIOL for hyperopic eyes because complication rates, particularly pigment dispersion, might be higher than those in myopic eyes. More well-designed, long-term studies are needed, especially in hyperopic eyes. The authors advocate for standardized reporting of refractive surgery data. Initiatives proposed by journal authors and editors to achieve uniformity should be supported.


Subject(s)
Hyperopia/surgery , Iris/surgery , Lens Implantation, Intraocular/methods , Myopia/surgery , Phakic Intraocular Lenses , Follow-Up Studies , Humans , Refraction, Ocular/physiology , Treatment Outcome , Visual Acuity/physiology
14.
Graefes Arch Clin Exp Ophthalmol ; 257(12): 2775-2787, 2019 Dec.
Article in English | MEDLINE | ID: mdl-31659458

ABSTRACT

PURPOSE: To evaluate the endothelial cell loss in patients with iris-claw phakic lenses (Artisan®) in a long-term follow-up. METHODS: We analyzed the medical records of patients who had undergone iris-claw phakic lens implantation and who had at least 5 years of follow-up. RESULTS: We included 67 eyes with myopic errors (follow-up 9.6 ± 3.0 years) and 10 eyes with mixed astigmatism or hyperopic errors (follow-up 8.8 ± 2.5 years). The mean total endothelial density loss at the last follow-up visit was 18.5% ± 17.0% and 10.5% ± 12.3%, respectively. 29.9% of the eyes in the myopic group and 20% in the hyperopic group lost more than 25% of the preoperative endothelial cell density. During the postoperative follow-up period, 60.8% of the eyes in the myopic group and 40% of the eyes in the hyperopic group lost a higher percentage than the expected physiological loss. Two eyes in the myopic group (3.0%) had a final cell density of less than 1200 cells/mm2. None of the variables studied had a statistically significant association with the percentage of annual endothelial loss in the postoperative period. Three phakic lenses were explanted: two by cataract and one by cataract and severe decrease of the endothelial density (862 cells/mm2). CONCLUSIONS: There is a significant endothelial cell loss in a low percentage of the eyes with Artisan® lenses in the long term, and it can decrease to critical levels. Periodic endothelial density evaluations are required for these patients. The selection criteria of surgical candidates could be reevaluated.


Subject(s)
Corneal Endothelial Cell Loss/etiology , Endothelium, Corneal/pathology , Iris/surgery , Lens Implantation, Intraocular/adverse effects , Myopia/surgery , Phakic Intraocular Lenses/adverse effects , Refraction, Ocular/physiology , Adult , Cell Count , Corneal Endothelial Cell Loss/diagnosis , Female , Follow-Up Studies , Humans , Male , Myopia/physiopathology , Postoperative Complications , Prosthesis Design , Retrospective Studies , Time Factors , Visual Acuity , Young Adult
15.
Arch Soc Esp Oftalmol (Engl Ed) ; 94(8): 367-376, 2019 Aug.
Article in English, Spanish | MEDLINE | ID: mdl-31266666

ABSTRACT

INTRODUCTION: Fluctuating elevated intraocular pressure (IOP) is one of the complications of an implantable collamer lens (ICL), and its alteration is a predictive factor for the development of glaucoma. MATERIAL AND METHODS: A prospective, cross-sectional analytic study was conducted on patients suitable for ICL implantation. Complete clinical and biometric work-ups were performed, as well as night-time IOP curve, in supine position, with 4 determinations, in order to assess fluctuation, considering abnormal with a value higher than 5 mmHg. Patients underwent surgery with conventional technique and three months after the work-ups were repeated, including a night-time IOP curve to assess any changes in IOP fluctuations. RESULTS: A total of 31 eyes of 16 patients were studied. Mean IOP fluctuation in the preoperative assessment was 3.35 ± 2 mmHg, whereas the postoperative mean was 3.0 ± 2.2 mmHg, with the difference not being statistically significant. Visual acuity and capacity, as well as spheric equivalent did show a statistically significant improvement. There were 6 cases of complications, which were related to a higher vault and a greater ICL size. There was no relationship between these findings and the angle grade, pigment, and the level of training of the surgeon. CONCLUSIONS: The effect of an ICL on IOP fluctuations, has been studied for the first time, which was found to be not statistically significant. As in previous publications, the procedure was safe and reproducible, adding the fact that the level of training of the surgeon is not a determining factor in these findings.


Subject(s)
Intraocular Pressure/physiology , Ocular Hypertension/physiopathology , Phakic Intraocular Lenses/adverse effects , Postoperative Complications/physiopathology , Adult , Cross-Sectional Studies , Female , Follow-Up Studies , Glaucoma/etiology , Humans , Lens Implantation, Intraocular/methods , Male , Mexico , Postoperative Period , Preoperative Period , Prospective Studies , Reproducibility of Results , Time Factors , Visual Acuity , Young Adult
16.
Rev. cuba. oftalmol ; 32(2): e612, abr.-jun. 2019. tab
Article in Spanish | LILACS | ID: biblio-1093688

ABSTRACT

RESUMEN Objetivo: Describir los efectos sobre la tensión ocular y el endotelio corneal con el implante de la lente fáquica ACR-128 para la corrección de la alta miopía. Métodos: Se realizó un estudio descriptivo, observacional, longitudinal y prospectivo en 60 ojos de 32 pacientes con miopía corregida con lente fáquica ACR-128. Se determinaron las complicaciones trans y posoperatorias, la presión intraocular, la densidad de las células endoteliales, el coeficiente de variabilidad y la hexagonalidad, así como la posición de la lente. El análisis estadístico se realizó con la Prueba T para datos pareados, con una significación del 95 por ciento. Resultados: La edad media fue de 27,41 ± 5,91 años y el 68,75 por ciento correspondió al sexo femenino. El equivalente esférico preoperatorio promedio fue de -11,54 ± 3,20 dioptrías. Resultó sin complicaciones transoperatorias el 100 por ciento; las posoperatorias inmediatas fueron de 93,33 por ciento y las mediatas y tardías del 95,00 por ciento. No hubo diferencias significativas entre el pre y el posoperatorio en la tensión ocular (p=0,2570); la densidad endotelial fue p= 0,0928; el coeficiente de variación p= 0,889 y la hexagonalidad (p= 0,0957). Conclusiones: El implante de la lente fáquica ACR-128 para la corrección de las altas miopías es un procedimiento seguro, al ofrecer escasas complicaciones y mínimos efectos en la tensión ocular y en el endotelio corneal(AU)


ABSTRACT Objective: Describe the effects of ACR-128 phakic lens implantation for high myopia correction on ocular tension and the corneal endothelium. Methods: An observational descriptive longitudinal prospective study was conducted of 60 eyes of 32 patients with myopia corrected with the ACR-128 phakic lens. Determination was made of intra- and postoperative complications, intraocular pressure, endothelial cell density, variability and hexagonality quotient, and lens position. Statistical analysis was based on the paired T-test with a significance level of 95 percent. Results: Mean age was 27.41 ± 5.91 years and 68.75 percent of the patients were female. Mean preoperative spherical equivalent was -11.54 ± 3.20 diopters. Complications were none in the intraoperative period, 93.33 percent in the immediate postoperative period and 95.00 percent mid- or long-term. No significant differences were found between the pre- and postoperative periods concerning ocular tension (p= 0.2570). Endothelial cell density was p= 0.0928, the variability quotient p= 0.889 and hexagonality p= 0.0957. Conclusions: ACR-128 phakic lens implantation for correction of high myopia is a safe procedure causing few complications and minimal effects on ocular tension and the corneal endothelium(AU)


Subject(s)
Humans , Male , Adult , Endothelium, Corneal/abnormalities , Myopia, Degenerative/diagnosis , Phakic Intraocular Lenses/adverse effects , Intraocular Pressure , Epidemiology, Descriptive , Prospective Studies , Longitudinal Studies , Observational Studies as Topic
17.
Rev. cuba. oftalmol ; 32(2): e611, abr.-jun. 2019. tab
Article in Spanish | LILACS | ID: biblio-1093686

ABSTRACT

RESUMEN Objetivo: Describir los resultados visuales en la corrección de la alta miopía con implante de lente fáquica ACR-128. Métodos: Se realizó un estudio descriptivo, observacional longitudinal y prospectivo en 60 ojos de 32 pacientes con miopía corregida con lente fáquica ACR-128. Se determinó el componente esférico esperado y observado, el cilindro queratométrico, las agudezas visuales sin corrección y mejor corregidas en el pre y en el posoperatorio y el astigmatismo inducido. El análisis estadístico se realizó con la Prueba T para datos pareados, con una significación del 95 por ciento. Resultados: La edad media fue 27,41 ± 5,91 años, el equivalente esférico preoperatorio -11,54 ± 3,20 dioptrías y el 68,75 por ciento eran femeninas. El componente esférico en dioptrías esperado (-0,53 ± 0,37) y observado (-0,42 ± 0,47) sin diferencias (p= 0,0742). Entre ± 1,00 el 91,67 por ciento y entre ± 0,50 el 70 por ciento. Ningún ojo quedó por encima de +0,50 dioptrías. El cilindro queratométrico en dioptrías, pre (1,44 ± 0,76) y posoperatorio (1,49 ± 0,84) sin astigmatismo inducido (p= 0,6377). El 100 por ciento tenía agudeza visual sin corrección preoperatoria ≤ 0,1 y posoperatoria ≥ 0,3. Después de la cirugía el 10 por ciento alcanzaba 1,0 y 71,6 por ciento ≥ 0,5. Solo el 28,33 por ciento tenía la unidad en el preoperatorio, y el 70 por ciento en el posoperatorio (98,33 por ciento ≥ 0,7). Conclusiones: El implante de lente fáquica ACR-128 proporciona corrección refractiva y predictibilidad favorables para el paciente, al reducir el componente esférico al deseado, no inducir astigmatismo y mejorar la agudeza visual, todo lo que se traduce en un adecuado resultado visual(AU)


ABSTRACT Objective: Describe the visual results of correction of high myopia with ACR-128 phakic lens implantation. Methods: An observational descriptive longitudinal prospective study was conducted of 60 eyes of 32 patients with myopia corrected with the ACR-128 phakic lens. Determination was made of the expected and observed spherical component, the keratometric cylinder, uncorrected and best corrected visual acuity in the pre- and postoperative periods, and induced astigmatism. Statistical analysis was based on the paired T-test with a significance level of 95 percent. Results: Mean age was 27.41 ± 5.91 years, preoperative spherical equivalent was -11.54 ± 3.20 diopters, and 68.75 percent of the patients were female. Spherical component in diopters expected (-0.53 ± 0.37) and observed (-0.42 ± 0.47) without differences (p= 0.0742). Between ± 1.00 diopters 91.67 percent and between ± 0.50 diopter 70 percent. No eye was above +0.50D. Keratometric cylinder in diopters, preoperative (1.44 ± 0.76) and postoperative (1.49 ± 0.84) without induced astigmatism (p=0.6377). In 100 percent visual acuity without correction ≤ 0.1 preoperative and ≥ 0.3 postoperative. After surgery 10 percent reached 1.0 and 71.6 percent ≥ 0.5. Only 28.33 percent had the unit corrected in the preoperative period and 70 percent in the postoperative period (98.33 percent ≥ 0.7). Conclusions: ACR-128 phakic lens implantation provides patients with favorable refractive correction and predictability. This is achieved by reducing the spherical component to desired values, not inducing astigmatism and improving visual acuity, all of which leads to an adequate visual result(AU)


Subject(s)
Humans , Female , Adult , Refractive Surgical Procedures/methods , Phakic Intraocular Lenses/adverse effects , Myopia/etiology , Epidemiology, Descriptive , Prospective Studies , Longitudinal Studies , Observational Study
18.
J Cataract Refract Surg ; 45(4): 519-522, 2019 04.
Article in English | MEDLINE | ID: mdl-30686702

ABSTRACT

The implantable collamer lens (ICL) is a widely used posterior chamber phakic intraocular lens that achieves excellent refractive results. Nonetheless, serious postoperative complications related to inadequate vault have been previously reported. Therefore, lens exchange is advised when the vault is out of the recommended ranges. This article presents a case with persistent low vault after lens exchange in which no clinical evidence of crystalline lens opacity or decrease in uncorrected distance visual acuity has been identified during the 6-year clinical follow-up performed to date. Therefore, this suggests that clinical follow-up could be an appropriate approach for patients presenting with low vault, especially those who are older than 40 years and have a history of lens exchange.


Subject(s)
Anterior Capsule of the Lens/pathology , Lens Diseases/etiology , Lens Implantation, Intraocular/adverse effects , Phakic Intraocular Lenses/adverse effects , Postoperative Complications , Adult , Anterior Capsule of the Lens/diagnostic imaging , Corneal Pachymetry , Corneal Topography , Female , Follow-Up Studies , Humans , Keratomileusis, Laser In Situ , Lasers, Excimer/therapeutic use , Lens Diseases/diagnostic imaging , Myopia/surgery , Reoperation , Tomography, Optical Coherence , Visual Acuity/physiology
19.
Rev. cuba. oftalmol ; 31(2): 1-13, abr.-jun. 2018.
Article in Spanish | CUMED | ID: cum-73519

ABSTRACT

La cirugía refractiva es una subespecialidad que comprende todos los procedimientos quirúrgicos dirigidos a modificar la refracción ocular en sus distintas ametropías. Su finalidad es mejorar la agudeza visual no corregida y simultáneamente disminuir la dependencia de los anteojos o lentes de contacto. Existen diferentes opciones como son: los procedimientos queratorrefractivos y los implantes de lentes intraoculares, con extracción del cristalino (pseudofaquia) o en un ojo fáquico, entre la córnea y el cristalino. En ocasiones es necesaria la combinación de más de un procedimiento. Las lentes intraoculares fáquicas pueden dividirse en dos grupos: lentes de cámara anterior, que incluye las de soporte angular y las de fijación iridiana, y lentes de cámara posterior, que son las implantadas en surco. A diferencia de la cirugía láser sobre la córnea o de la cirugía del cristalino, la corrección de ametropías moderadas-severas mediante estas lentes permite mantener la acomodación, además de obtener una mejor calidad óptica, cierta reversibilidad del procedimiento y la posibilidad de mejorar defectos refractivos residuales mediante la cirugía corneal mínima. De ahí la motivación para realizar una búsqueda de diversos artículos publicados, con el objetivo de describir todos los tipos de lentes intraoculares en ojos fáquicos y sus ventajas. Se utilizó la plataforma Infomed, específicamente la Biblioteca Virtual de Salud, con todos sus buscadores(AU)


Refractive surgery is a subspecialty comprising all the surgical procedures aimed at modifying ocular refraction in its various ametropias. Its aim is to improve uncorrected visual acuity, reducing dependence on eyeglasses or contact lenses. There are different options, such as keratorefractive procedures and intraocular lens implantation, with removal of the crystalline lens (pseudophakia) or in phakic eyes, between the cornea and the crystalline lens. A combination of more than one procedure is sometimes required. Phakic intraocular lenses are divided into two groups: anterior chamber lenses, including the angle-supported and iris fixation types, and posterior chamber lenses, performed by sulcus implantation. Unlike laser corneal or crystalline lens surgery, correction of moderate-to-severe ametropia using these lenses makes it possible to retain accommodation, and provides better optical quality, a certain reversibility of the procedure, and the possibility of correcting residual refractive defects by minimum corneal surgery. Hence the motivation to conduct an updated search in various published papers with the purpose of describing all the types of phakic intraocular lenses and their advantages. Use was made of the Infomed platform, particularly the Virtual Health Library with all its search engines(AU)


Subject(s)
Humans , Refractive Surgical Procedures/methods , Lasers, Excimer/therapeutic use , Phakic Intraocular Lenses/adverse effects , Libraries, Digital
20.
Rev. cuba. oftalmol ; 31(2): 1-10, abr.-jun. 2018. ilus
Article in Spanish | CUMED | ID: cum-73518

ABSTRACT

La alta miopía es aquella igual o mayor a -6 dioptrías esféricas, no en función de la curvatura corneal elevada, como es el caso del queratocono, ni por la esclerosis del cristalino que ocurre en etapas preseniles, sino en dependencia de la longitud axial mayor de 25,5 o 26,0 mm. La corrección óptica de estos defectos altos es difícil, ya que es frecuente que los pacientes se sientan incómodos con el uso de gafas, pues no obtienen una buena calidad de visión, y con el fin de mejorarla se han desarrollado distintos procedimientos quirúrgicos. Se presenta una paciente de 26 años de edad con miopía elevada, quien no se adapta a los lentes de contacto y no desea continuar con los espejuelos; no es candidata a la cirugía refractiva corneal. Se le implantaron lentes fáquicas ACR IOL-128 (Soleko, Italia) sin complicaciones. El equivalente esférico preoperatorio -11,5 y -6 dioptrías disminuyó a -1,00 y -0,5 respectivamente, y la agudeza visual sin cristales de cuenta dedos y 0,1 a 0,8 y 0,9 respectivamente. Con este caso se evidencia que las lentes fáquicas son una opción con buenos resultados en la corrección de la alta miopía(AU)


The high myopia, by definition, is that equal or bigger to -6 spherical dioptrías; not in function of the bend high corneal, like it is the case of the queratocono, neither for the sclerosis of the crystalline lens that happens in stages preseniles, but in dependence of the axial longitude bigger than 25,5 or 26,0 mm. The optic correction of these high defects is difficult, since it is frequent that the patients feel uncomfortable with the glasses use, because they don't obtain a good quality of vision and with the purpose of improving it, different surgical procedures have been developed. Young patient 26 years old is presented with high myopia that doesn't adapt to the contact eyeglasseses and she doesn't want to continue with the espejuelos, she is not candidate to surgery refractive corneal and she is implanted eyeglasseses fáquica ACR IOL-128 (Soleko, Italy) without complications. The equivalent spherical preoperatorio -11,5 and -6 dioptrías diminish at -1,00 and - 0,5 respectively and the visual sharpness without glasses of bill fingers and 0,1 at 0,8 and 0,9 respectively. With this case it is evidenced that the lenses fáquicas are an option with good results in the correction of the high myopia(AU)


Subject(s)
Humans , Female , Adult , Lasers, Excimer/therapeutic use , Phakic Intraocular Lenses , Myopia/diagnosis