Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 91
Filter
1.
Vet Rec ; 194(9): e4088, 2024 05 04.
Article in English | MEDLINE | ID: mdl-38637964

ABSTRACT

BACKGROUND: Ophthalmoscopy is a valuable tool in clinical practice. We report the use of a novel smartphone-based handheld device for visualisation and photo-documentation of the ocular fundus in veterinary medicine. METHODS: Selected veterinary patients of a referral ophthalmology service were included if one or both eyes had clear ocular media, allowing for examination of the fundus. Following pharmacological mydriasis, fundic images were obtained with a handheld fundus camera (Volk VistaView). For comparison, the fundus of a subset of animals was also imaged with a veterinary-specific fundus camera (Optomed Smartscope VET2). RESULTS: The large field of view achieved by the Volk VistaView allowed for rapid and thorough observation of the ocular fundus in animals, providing a tool to visualise and record common pathologies of the posterior segment. Captured fundic images were sometimes overexposed, with the tapetal fundus artificially appearing hyperreflective when using the Volk VistaView camera, a finding that was less frequent when activating a 'veterinary mode' that reduced the sensitivity of the camera's sensor. The Volk VistaView compared well with the Optomed Smartscope VET2. LIMITATION: The main study limitation was the small sample size. CONCLUSIONS: The Volk VistaView camera was easy to use and provided good-quality fundic images in veterinary patients with healthy or diseased eyes, offering a wide field of view that was ideal for screening purposes.


Subject(s)
Retinal Diseases , Smartphone , Veterinary Medicine , Animals , Retinal Diseases/veterinary , Retinal Diseases/diagnosis , Veterinary Medicine/instrumentation , Ophthalmoscopy/veterinary , Ophthalmoscopy/methods , Fundus Oculi , Photography/veterinary , Photography/instrumentation , Dogs , Dog Diseases/diagnosis , Cats
2.
Vet Ophthalmol ; 26(5): 378-384, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37170669

ABSTRACT

OBJECTIVE: To describe a protocol for corneal ulcer monitoring utilizing daily fluorescein staining and evaluation of owner-acquired anterior segment images. ANIMAL STUDIED: Nine client-owned small animal patients (eight dogs, one cat) diagnosed with superficial corneal ulcers at the University of Georgia Veterinary Capitalize Hospital. PROCEDURE(S): In addition to routine ulcer therapy, patients were discharged with supplies to perform daily fluorescein staining including a Quikvue® cobalt blue light camera adapter. Fluorescein staining was performed daily, photographs and/or videos were acquired at home by the patient's owner(s), and images were analyzed daily by trained personnel. In-house examinations were performed weekly and within 24 h after the ulcer had appeared healed on photographs. RESULTS: All (9/9) owners were able to take interpretable photographs. The majority (6/9) of patients had images successfully detailing their ulcer healing progress. One (1/9) patient appeared healed on images, but on subsequent examination had persistent ulceration covered by third eyelid elevation. Two (2/9) patients had persistent ulceration, consistent on both images and examination, but exited the study prematurely prior to ulcer healing. CONCLUSIONS: Remote fluorescein staining and image evaluation can be considered as an adjunct for monitoring ulcer healing but should not be used alone or as a substitute for ophthalmic examinations. Ulcers under the third eyelid have potential to be missed on image evaluation alone.


Subject(s)
Corneal Ulcer , Dog Diseases , Animals , Dogs , Corneal Ulcer/diagnosis , Corneal Ulcer/veterinary , Ulcer/veterinary , Fluorescein , Pilot Projects , Photography/veterinary , Staining and Labeling/veterinary , Dog Diseases/diagnostic imaging
3.
Vet Rec ; 190(1): 5, 2022 01.
Article in English | MEDLINE | ID: mdl-34994456
4.
Integr Zool ; 16(2): 226-239, 2021 Mar.
Article in English | MEDLINE | ID: mdl-33150697

ABSTRACT

Provision of food and water is a widespread tool implemented around the world for the benefit of game and other wildlife, but factors affecting the use of food and water by non-target species are poorly known. We evaluated visits to feeders and water troughs by non-game species using camera-traps in two separate areas of Spain. Feeders and water troughs were either "protected" (when surrounded by more than 50% of shrubs/forest) or "open" (in the opposite case). A total of 18 948 photos from 5344 camera-trapping days depicted animals, and 75 species were identified. Feeders and water troughs were visited by target species (partridges and lagomorphs, 55.3% of visits) and non-target species (44.7% of visits). Among the latter, corvids were the most common (46.1% of visits), followed by rodents (26.8%), other birds (23.6%, mainly passerines), columbids (1.9%), and other species at minor percentages. The highest proportion of visiting days to feeders and water troughs was from corvids (0.173) followed by other-birds (0.109) and rodents (0.083); the lowest proportion was recorded for columbids (0.016). Use intensity and visit frequency of water troughs tripled that recorded in feeders, and visits to open feeders/troughs were approximately twice those to protected ones. In summary: feeders and water troughs targeting small game species are also used regularly by non-target ones; they should be set close to cover to optimize their use by non-target species that are not competitors of target species (though corvids may visit them); water availability should be prioritized where drought periods are expected.


Subject(s)
Animals, Wild , Drinking Behavior , Feeding Behavior , Animal Feed , Animals , Photography/veterinary , Spain , Water
5.
J Insect Sci ; 20(6)2020 Nov 01.
Article in English | MEDLINE | ID: mdl-33135753

ABSTRACT

The horn fly, Haematobia irritans L. (Diptera: Muscidae), is a persistent pest of cattle globally. A threshold of 200 flies per animal is considered the standard management goal; however, determining when that threshold has been exceeded is difficult using visual estimates that tend to overestimate the actual fly densities and are, at best, subjective. As a result, a more reliable and durable method of determining horn fly densities is needed. Here, we describe the methods commonly used to quantify horn fly densities including visual estimates and digital photography, and provide examples of quantification software and the prospect for computer automation methods.


Subject(s)
Entomology/methods , Insect Control/methods , Muscidae , Animals , Entomology/instrumentation , Insect Control/instrumentation , Photography/veterinary , Population Density
6.
Vet Rec ; 187(12): e126, 2020 Dec 19.
Article in English | MEDLINE | ID: mdl-33033104

ABSTRACT

BACKGROUND: Drilling accuracy is essential in the correct positioning of implants and avoidance of iatrogenic damage to surrounding tissues. The use of augmented drilling methods has been documented as an approach to improving the accuracy of drilling. The aim of this study was to compare the accuracy of two augmented drilling methods (fluoroscopically guided and aiming device) to freehand (FH) drilling. METHODS: Three experienced specialist surgeons and three veterinary surgeons without primary orthopaedic experience drilled into synthetic bone towards a target using the three different methods at three different angles (0°, 10° and 20°). The duration of drilling was recorded, and the accuracy of drilling was measured using photographs before and after drilling. RESULTS: The two augmented methods were more accurate than FH drilling in synthetic bone, with the aiming device producing the greatest accuracy. Increased angulation of drilling decreased the drilling accuracy. Surgeon experience did not impact on drilling accuracy. Surgeon inexperience and augmented drilling methods both increased the time taken to drill. CONCLUSION: The use of augmented drilling methods improved the accuracy of drilling, and surgeons should consider their use when drilling in anatomical regions where the margin of error is small.


Subject(s)
Fluoroscopy/veterinary , Orthopedic Procedures/veterinary , Surgery, Veterinary/methods , Animals , Fluoroscopy/methods , Humans , Orthopedic Procedures/methods , Photography/veterinary
7.
Anat Histol Embryol ; 49(6): 779-787, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32537746

ABSTRACT

The conventional anatomical study of specimens requires cutting processes which destruct the limited specimens. A non-destructive method, namely an ultrasonography, can be used to assess the anatomical organ information of those specimens. The aim of this research is to analyse the macroanatomy of the female reproductive organ in the Sunda porcupine (Hystrix javanica), using ultrasonographical imaging. In this study, four formaldehyde-fixed reproductive organ specimens of the Sunda porcupine were used. A 10-12 MHz linear ultrasound transducer was utilized to provide an imaging format of both longitudinal and transversal views. Photographic images were then used as comparison with a sonographic image. The results show that the ultrasound image of the Sunda porcupine reproductive organ soft tissue was hypoechoic, the lumen and antrum follicles were anechoic, while atretic follicles and the mons pubis were hyperechoic. Generally, the size of the organ was not significantly different between photographical and ultrasonographical imaging (p > .05). In conclusion, ultrasound images can be utilized for anatomical studies of the Sunda porcupine reproductive organs without destructing the specimen.


Subject(s)
Genitalia, Female/diagnostic imaging , Porcupines/anatomy & histology , Animals , Fallopian Tubes/anatomy & histology , Fallopian Tubes/diagnostic imaging , Female , Genitalia, Female/anatomy & histology , Photography/veterinary , Reproducibility of Results , Ultrasonography/veterinary , Uterus/anatomy & histology , Uterus/diagnostic imaging , Vagina/anatomy & histology , Vagina/diagnostic imaging , Vulva/anatomy & histology , Vulva/diagnostic imaging
8.
Sci Rep ; 9(1): 17209, 2019 11 20.
Article in English | MEDLINE | ID: mdl-31748588

ABSTRACT

The Philippines is home to the second largest known population of whale sharks in the world. The species is listed as endangered due to continued population declines in the Indo-Pacific. Knowledge about the connectivity within Southeast Asia remains poor, and thus international management is difficult. Here, we employed pop-up archival tags, data mining and dedicated effort to understand an aggregation of whale sharks at Honda Bay, Palawan, Philippines, and its role in the species' conservation. Between Apr and Oct 2018, we conducted 159 surveys identifying 117 individual whale sharks through their unique spot patterns (96.5% male, mean 4.5 m). A further 66 individual whale sharks were identified from local operators, and data mined on social media platforms. The satellite telemetry data showed that the whale sharks moved broadly, with one individual moving to Sabah, Malaysia, before returning to the site <1 year later. Similarly, another tagged whale shark returned to the site at a similar periodicity after reaching the Malay-Filipino border. One individual whale shark first identified in East Kalimantan, Indonesia by a citizen scientist was resighted in Honda Bay ~3.5 years later. Honda Bay is a globally important site for the endangered whale shark with connectivity to two neighbouring countries, highlighting the need for international cooperation to manage the species.


Subject(s)
Animal Migration , Behavior, Animal/physiology , Pattern Recognition, Visual , Photography/veterinary , Sharks/physiology , Telemetry/veterinary , Animals , Female , Indonesia , Malaysia , Male , Philippines , Photography/methods , Telemetry/methods
9.
J Dairy Sci ; 102(6): 5466-5474, 2019 Jun.
Article in English | MEDLINE | ID: mdl-30954267

ABSTRACT

Digital dermatitis (DD) is the leading infectious cause of lameness in dairy cattle, and it affects their welfare and productivity worldwide. At the herd level, DD is often assessed while cows are standing in a milking parlor, and lesions are most commonly evaluated using the M-score. The objective of this study was to examine the interobserver agreement for M-scores of the feet of standing cattle, based on digital color photographs of dairy cattle hind feet. A total of 88 photographs and written descriptors of the M-score were sent to 11 scorers working at 10 different institutions in 5 countries. The scorers received no formal training immediately before scoring the photographs; however, all regularly used the M-score to score DD. The answers for 36 photographs were excluded from the analysis because the photograph either had more than 1 M-stage as mode or not all scorers assigned an M-score to it. The M-scores of the 11 scorers from 52 photographs were available for analysis. Interobserver agreement was tested using Gwet's agreement coefficient (AC1) and the mode was assumed correct. Overall, moderate agreement emerged for the M-score (AC1 = 0.48). For the individual M-stages, almost perfect agreement existed for M0 (AC1 = 0.99), M1 (AC1 = 0.92), and M3 (AC1 = 0.82), and substantial agreement for M2 (AC1 = 0.61), M4 (AC1 = 0.65), and M4.1 (AC1 = 0.71). This outcome indicates the degree of individual variation in M-scoring in this context by unstandardized, experienced European observers, particularly for the M2, M4, and M4.1 stages. Standardized training is likely to improve the consistency of M-scoring and thus the generalizability of future DD research results on this important endemic disease.


Subject(s)
Cattle Diseases/pathology , Digital Dermatitis/pathology , Foot Diseases/veterinary , Lameness, Animal/pathology , Observer Variation , Animals , Cattle , Dairying , Female , Foot/pathology , Foot Diseases/pathology , Hoof and Claw/pathology , Milk , Photography/veterinary
10.
Vet Ophthalmol ; 22(3): 381-384, 2019 May.
Article in English | MEDLINE | ID: mdl-30838772

ABSTRACT

OBJECTIVE: The purpose of this study is to measure parameters of the anterior segment of normal feline eyes using a rotating Scheimpflug camera in young and adult cats. PROCEDURE: Sixteen domestic short-haired (DSH) healthy cats (seven castrated males and nine spayed females) with a mean age of 17 months (SD = 3.5) were anesthetized. Cats were considered immature and adults if they were < or ≥12 months of age, respectively. The keratometric values, the anterior chamber depth (ACD), and central corneal thickness (CCT) of the right eye of each animal were measured using a Pentacam Oculus topographer. The repeatability of the measures was assessed by calculating the coefficient of variation of the successive measures in cats (five repetitions per cat). We performed an ANOVA to test the effect of age on the parameters measures. RESULTS: The mean CCT and ACD were 601.97 ± 38 µm and 5.27 ± 0.04 mm, respectively. No significant differences were observed between adult and young cat's measures. The average keratometric value was 39.6 ± 0.3 D. The mean average cylindrical error was 2.48 ± 0.35 D (43.75% "against-the-rule" astigmatism and 43.75% "oblique" astigmatism). CONCLUSION: The Oculus Pentacam under clinical conditions give CCT and ACD values very similar to those reported in previous studies. Corneal astigmatism measures were markedly elevated (>2 D). Further studies with a larger population of cats of various breeds and ages are needed to confirm or refute these results, using a rotating Scheimpflug camera.


Subject(s)
Anterior Eye Segment/anatomy & histology , Cats/anatomy & histology , Animals , Anterior Eye Segment/diagnostic imaging , Corneal Pachymetry/veterinary , Female , Male , Photography/veterinary , Reference Values
11.
J Dairy Sci ; 102(5): 4294-4308, 2019 May.
Article in English | MEDLINE | ID: mdl-30879819

ABSTRACT

Machine vision technology has been used in automated body condition score (BCS) classification of dairy cows. The current vision-based classifications use information acquired from a limited number of body regions of the cow. Our study aimed to improve automated BCS classification by including multiple body condition-related features extracted from 3 viewpoints in 8 body regions. The data set of this study included 44 lactating cows with their BCS evenly distributed over the scale of BCS from 1.5 to 4.5 units. The body images of these cows were recorded over 2 consecutive days using 3-dimensional cameras positioned to view the cow from the top, right side, and rear. Each image was automatically processed to identify anatomical landmarks on the body surface. Around these anatomical landmarks, the bony prominences and body surface depressions were quantified to describe 8 body condition-related features. A manual BCS of each cow was independently assigned by 2 trained assessors using the same predefined protocol. With the extracted features as inputs and manual BCS as the reference, we built a nearest-neighbor classification model to classify BCS and obtained an overall classification sensitivity of 0.72 using a 10-fold cross-validation. We conclude that the sensitivity of automated BCS classification has been improved by expanding the selection of body condition-related features extracted from multiple body regions.


Subject(s)
Cattle , Health Status Indicators , Photography/veterinary , Animals , Automation , Cattle/anatomy & histology , Dairying , Female , Image Processing, Computer-Assisted , Lactation
12.
Vet Ophthalmol ; 22(5): 683-694, 2019 Sep.
Article in English | MEDLINE | ID: mdl-30715790

ABSTRACT

OBJECTIVE: To describe and compare normative anterior segment parameters between canine age groups using the Pentacam® HR Scheimpflug camera (Pentacam). ANIMALS STUDIED: Thirty-six sedated dogs (60 eyes) of varying ages and breeds were imaged with the Pentacam; only nondiseased anterior segments were included. PROCEDURES: Dogs were divided into three age groups: Group 1 (1-5 years), Group 2 (6-10 years), and Group 3 (11-15 years). Values assessed included central corneal thickness (CCT), anterior and posterior corneal elevation (ACE/PCE), anterior and posterior corneal curvature metrics, corneal volume (CV), anterior and posterior corneal astigmatism (AA/PA), anterior chamber depth (ACD), anterior chamber volume (ACV), and anterior chamber angle (ACA). Tukey-adjusted pairwise comparisons were performed. RESULTS: Overall CCT (mean ± SD) was 631.07 ± 59.91 µm. Central corneal thickness was 608.60 ± 48.63 µm for Group 1, 648.57 ± 51.06 µm for Group 2, and 635.37 ± 73.71 µm for Group 3. Anterior corneal elevation (ACE) measured 9.08 ± 0.58 mm, PCE measured 8.04 ± 0.50 mm, and CV was 58.13 ± 5.39 mm3 . Astigmatism values were 1.34 ± 0.94 D for AA and 0.46 ± 0.44 D for PA. Anterior chamber values were 3.76 ± 0.56 mm for ACD, 383.68 ± 66.24 mm3 for ACV, and 23.62 ± 29.33˚ for ACA. Significant differences were found between Groups 1 and 2 for CV (55.08 ± 4.08 mm3 and 60.32 ± 4.19 mm3 , respectively), (P = 0.02). CONCLUSIONS: Corneal volume significantly increased between Group 1 and Group 2. Central corneal thickness increased from Group 1 to Group 3, but was not significant with the current sample size. There were no other differences between age groups.


Subject(s)
Anterior Chamber/diagnostic imaging , Dogs/anatomy & histology , Animals , Anterior Chamber/anatomy & histology , Female , Male , Photography/veterinary , Slit Lamp/veterinary
13.
N Z Vet J ; 67(3): 143-147, 2019 May.
Article in English | MEDLINE | ID: mdl-30753789

ABSTRACT

AIMS: To assess the inter-observer agreement for detecting bovine digital dermatitis (BDD) lesions in digital colour photographs of the hind feet of cows, which had been taken while the animals were standing to be milked, between two trained observers. METHODS: Thirty-six photographs were selected from a total of 184 photographs held by the first author (R1), who had classified them as negative (n=11) or positive (n=25) for BDD. They were delivered to a technician (R2) who had previously visually inspected cattle for BDD lesions, and who then recorded the photographs as being either BDD-positive or BDD-negative. The percentage agreement between R1 and R2, and two other inter-observer agreement statistics, Cohen's κ and Gwet's first-order chance correction agreement coefficient (AC1), were calculated. The cumulative membership probabilities of Cohen's κ and Gwet's AC1 were then calculated for different benchmark ranges of κ. RESULTS: The percentage agreement between R1 and R2 was 33/36 (92%), Cohen's κ was 0.80 (95% CI=0.57-1.0) and Gwet's AC1 was 0.86 (95% CI=0.69-1.0). Based on the cumulative membership probabilities for Gwet's AC1, there was 75% probability that the two observers had almost perfect agreement (κ≥0.81). For both Cohen's κ and Gwet's AC1, there was >95% probability that the two observers had at least substantial agreement (κ≥0.61). CONCLUSIONS: The two trained observers had at least substantial agreement in identifying from a digital photograph as to whether BDD lesions were present or absent. Therefore results from the two could be used interchangeably. CLINICAL RELEVANCE: Visual assessment for BDD lesions in the milking parlour can be subjective. However a high agreement between these two trained BDD inspectors means BDD prevalence reported from different regions in New Zealand by these two can be directly compared.


Subject(s)
Cattle Diseases/diagnosis , Digital Dermatitis/diagnosis , Photography/veterinary , Animals , Cattle , Cattle Diseases/epidemiology , Cattle Diseases/pathology , Digital Dermatitis/epidemiology , Digital Dermatitis/pathology , Humans , New Zealand/epidemiology , Observer Variation
14.
BMC Vet Res ; 14(1): 269, 2018 Sep 03.
Article in English | MEDLINE | ID: mdl-30176905

ABSTRACT

BACKGROUND: The fluorescein clearance test (FCT) provides insight into the tear film dynamics. The purpose of this study was to describe an inexpensive and practical method for assessing FCT in dogs, using photography and software analysis, and to assess the retention time of 1 vs. 2 eye drops on the canine ocular surface. METHODS: (i) In vivo - Eight healthy German Shepherd dogs were recruited. Following topical anesthesia with 0.5% proxymetacaine, each eye sequentially received (1 week apart) either 1 drop (35 µL) or 2 drops (70 µL) of 0.5% fluorescein. A Schirmer strip was inserted in the ventral conjunctival fornix for 10 s at the following times: each 10 min for 100 min, 24 h, 48 h and 72 h. (ii) In vitro - Schirmer strips were placed for 10 s in contact with microplate wells containing 1 or 2 drops of 0.5% fluorescein. In both experiments, the fluorescein-impregnated Schirmer strips were immediately imaged, and the area and intensity of fluorescein uptake were analyzed with ImageJ software. For the in vitro experiment, images were evaluated by the same examiner (repeatability) or two examiners (reproducibility). RESULTS: Photography-based FCT was easy to perform and showed high repeatability and reproducibility (coefficients of variation ≤2.75%). In vivo, the area and intensity of fluorescein uptake on Schirmer strips were significantly greater at 30 min and 40 min post- fluorescein instillation in the 2 drops vs. 1 drop groups (p ≤ 0.044). Compared to baseline, the residual fluorescein uptake on Schirmer strips was < 5% at 60 min and 90 min in the 1 drop and 2 drops groups, respectively. CONCLUSIONS: Photography-based FCT is a practical and reliable diagnostic tool with various clinical and research applications in veterinary medicine. Instillation of two drops provided greater amount and longer retention on the anesthetized canine ocular surface than a single drop. Fluorescein clearance time of a single drop in dolichocephalic dogs is 60 min.


Subject(s)
Diagnostic Techniques, Ophthalmological/veterinary , Dogs , Fluorescein/pharmacokinetics , Photography/veterinary , Animals , Female , Fluorescein/administration & dosage , Male , Photography/methods , Reagent Strips , Reproducibility of Results , Tears/physiology
15.
J Exp Biol ; 221(Pt 19)2018 10 11.
Article in English | MEDLINE | ID: mdl-30127080

ABSTRACT

Loons (Gaviiformes) are arguably one of the most successful groups of swimming birds. As specialist foot-propelled swimmers, loons are capable of diving up to 70 m, remaining underwater for several minutes, and capturing fish. Despite the swimming prowess of loons, their undomesticated nature has prevented prior quantitative analysis. Our study used high-speed underwater cameras to film healthy common loons (Gavia immer) at the Tufts Wildlife Clinic in order to analyze their swimming and turning strategies. Loons swim by synchronously paddling their feet laterally at an average of 1.8 Hz. Combining flexion-extension of the ankle with rotation at the knee, loon swimming resembles grebe swimming and likely generates lift forces for propulsion. Loons modulate swimming speed by altering power stroke duration and use head bobbing to enhance underwater vision. We observed that loons execute tight but slow turns compared with other aquatic swimmers, potentially associated with hunting by flushing fish from refuges at short range. To execute turns, loons use several strategies. Loons increase the force produced on the outside of the turn by increasing the speed of the outboard foot, which also begins its power stroke before the inboard foot. During turns, loons bank their body away from the turn and alter the motion of the feet to maintain the turn. Our findings demonstrate that foot-propelled swimming has evolved convergently in loons and grebes, but divergently from cormorants. The swimming and turning strategies used by loons that allow them to capture fish could inspire robotic designs or novel paddling techniques.


Subject(s)
Birds/physiology , Foot/physiology , Swimming , Animals , Biomechanical Phenomena , Diving , Movement , Photography/veterinary
16.
Avian Dis ; 62(1): 65-72, 2018 03.
Article in English | MEDLINE | ID: mdl-29620454

ABSTRACT

The types of wildlife and the frequency of their visits to commercial chicken farms in Australia were assessed using infrared and motion-sensing camera traps. Cameras were set up on 14 free-range layer farms, three cage layer farms, two barn layer farms, five non-free-range meat chicken farms, and six free-range meat chicken farms in the Sydney basin region and South East Queensland. Wildlife visits were found on every farm type and were most frequent on cage layer farms (73%), followed by free-range layer farms (15%). The common mynah ( Acridotheres tristis) was the most frequent wildlife visitor in the study (23.9%), followed by corvids (22.9%) and Columbiformes (7.5%). Most wildlife visits occurred during the day from 6 am to 6 pm (85%). There were infrequent observations of direct contact between chickens and wildlife, suggesting the indirect route of pathogen transfer may be more significant. The level of biosecurity on the farm is suggested to impact the frequency of wildlife visits more so than the farm type.


Subject(s)
Animal Distribution , Animals, Wild/physiology , Chickens/physiology , Photography/veterinary , Animal Husbandry , Animals , Birds , New South Wales , Queensland
18.
J Med Entomol ; 54(4): 980-984, 2017 07 01.
Article in English | MEDLINE | ID: mdl-28399282

ABSTRACT

Horn fly, Haematobia irritans (L.), population estimates often serve as a diagnostic tool prior to implementing managerial control options available to researchers and producers. Digital photographs taken of cattle infested with horn flies have been suggested to provide similarly accurate population estimates as compared with traditional visual assessments. The objective of this study was to compare visual and digital techniques used to estimate horn fly populations. Sixteen Angus × Hereford yearling heifers artificially infested with four levels of horn flies (Low = 0 flies; Medium = 250 flies; High = 500 flies; Extreme = 1,000 flies) were evaluated. Population estimates were taken visually by experienced (VE1) and inexperienced (VE2) technicians, as well as digitally, with photographs taken on both lateral sides of the south-facing animal. Horn flies were counted in both photographs and combined (CDC) for full body estimates. In addition, the highest photographed side population times two (DDC) was used for comparison. Estimations were made at 0700, 1200, and 1900 h the day following infestation. A time of observation × infestation level interaction (P < 0.01) was detected. On average, VE1 population estimates were greater (P < 0.01) than any other counting method observed. Morning estimates were greater (P < 0.05) than those taken at noon or in the early evening regardless of counting method. Further research regarding the standardization of these techniques to ensure more accurate population estimates is needed before these methods can be incorporated into integrated pest management programs.


Subject(s)
Entomology/methods , Muscidae/physiology , Parasitology/methods , Animals , Cattle , Cattle Diseases/parasitology , Ectoparasitic Infestations/parasitology , Ectoparasitic Infestations/veterinary , Female , Photography/veterinary , Population Density
19.
Parasitology ; 144(7): 877-883, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28345501

ABSTRACT

Widespread access to the internet is offering new possibilities for data collection in surveillance. We explore, in this study, the possibility of using an electronic tool to monitor occurrence of the tick vector of Lyme disease, Ixodes scapularis. The study aimed to compare the capacity for ticks to be identified in web-based submissions of digital images/photographs, to the traditional specimen-based identification method used by the provincial public health laboratory in Quebec, Canada. Forty-one veterinary clinics participated in the study by submitting digital images of ticks collected from pets via a website for image-based identification by an entomologist. The tick specimens were then sent to the provincial public health laboratory to be identified by the 'gold standard' method using a microscope. Of the images submitted online, 74·3% (284/382) were considered of high-enough quality to allow identification. The laboratory identified 382 tick specimens from seven different species, with I. scapularis representing 76% of the total submissions. Of the 284 ticks suitable for image-based species identification, 276 (97·2%) were correctly identified (Kappa statistic of 0·92, Z = 15·46, P < 0·001). This study demonstrates that image-based tick identification may be an accurate and useful method of detecting ticks for surveillance when images are of suitable quality.


Subject(s)
Epidemiological Monitoring/veterinary , Ixodes/classification , Pets/parasitology , Photography/veterinary , Animals , Female , Ixodes/anatomy & histology , Ixodes/growth & development , Larva/anatomy & histology , Larva/classification , Larva/growth & development , Nymph/anatomy & histology , Nymph/classification , Nymph/growth & development , Quebec
20.
Vet Ophthalmol ; 20(1): 89-94, 2017 Jan.
Article in English | MEDLINE | ID: mdl-26775579

ABSTRACT

OBJECTIVE: To assess the use of an optical device (D-EYE; Si14 S.p.A.) attached to a modern smartphone (iPhone 5; Apple Inc.) for imaging the fundus in small animals. ANIMALS STUDIED: Five dogs, five cats, and five rabbits with clear media were imaged using a prototype of the D-EYE. PROCEDURE: The optical device was composed of lenses, polarizing filters, a beam splitter, a diaphragm, and mirrors, attached to a smartphone via a metal shell. Images were obtained 20 min after pupil dilation with topical 0.5% tropicamide in a darkened room, to ensure maximum pupillary dilation. Focus was set to the infinite when the autofocus was overwhelmed. Light intensity was adapted to each animal via the application (minimum light intensity for imaging the tapetal region, maximum light intensity for imaging the nontapetal region). Both still images and video sequences were recorded for each animal. RESULTS: Posterior segment structures were visible in all animals: optic nerve head, tapetum lucidum (when present), nontapetal region, retinal vessels, and choroidal vessels (when the retinal pigment epithelium and the choroidal pigmentation were discreet). Focal light artifacts were common when photographing the tapetum lucidum. Recording videos allowed the visualization of dynamic phenomena. CONCLUSIONS: The D-EYE assessed appears to be an easy means of obtaining images of the posterior segment structures.


Subject(s)
Fundus Oculi , Smartphone , Animals , Cat Diseases/diagnostic imaging , Cats , Dog Diseases/diagnostic imaging , Dogs , Eye Diseases/diagnostic imaging , Eye Diseases/veterinary , Photography/instrumentation , Photography/methods , Photography/veterinary , Posterior Eye Segment/diagnostic imaging , Rabbits , Smartphone/instrumentation
SELECTION OF CITATIONS
SEARCH DETAIL
...