Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.120
Filter
1.
Biochem Biophys Res Commun ; 711: 149909, 2024 Jun 04.
Article in English | MEDLINE | ID: mdl-38615573

ABSTRACT

RNA analysis has shown great value in forensic science, such as body fluids and tissue identification, postmortem interval estimation, biological age prediction, etc. Currently, most RNA follow-up experiments involve reverse transcription (RT) procedures. It has been shown that the RT step is variable and has a greater impact on subsequent data analysis, especially for forensic trace samples. However, the pattern of variation between different RNA template inputs and complementary DNA (cDNA) yield is unclear. In this study, a series of 2-fold gradient dilutions of RNA standards (1 µg/µL - 0.24 ng/µL) and forensic samples (including blood samples, saliva samples, bloodstains, and saliva stains) were reverse-transcribed using EasyQuick RT MasterMix. The obtained cDNA was quantified by droplet digital PCR (ddPCR) to assess the RT yield of the ACTB gene. The results showed that the 125 ng RNA template had the highest RT yield in a 10 µL RT reaction system with the selected kit. For all stain samples, the RT yield improved as the amount of RNA template input increased since RNA quantities were below 125 ng. As many commercialized reverse transcription kits using different kinds of enzymes are available for forensic RNA research, we recommend that systematic experiments should be performed in advance to determine the amount of RNA input at the optimum RT yield when using any kit for reverse transcription experiments.


Subject(s)
RNA , Humans , RNA/genetics , RNA/analysis , Reverse Transcription , Saliva/metabolism , Saliva/chemistry , Forensic Genetics/methods , Forensic Genetics/standards , Reverse Transcriptase Polymerase Chain Reaction/standards , Reverse Transcriptase Polymerase Chain Reaction/methods , Reference Standards , DNA, Complementary/genetics , Blood Stains , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards
2.
Indian J Med Microbiol ; 44: 100354, 2023.
Article in English | MEDLINE | ID: mdl-37356844

ABSTRACT

PURPOSE: Human brucellosis is a neglected zoonotic disease of significant public health concern. Molecular diagnosis of brucella remains challenging in low resource settings, due to the high infrastructure and cost involved. Loop-mediated isothermal amplification (LAMP) is a rapid point of care polymerase chain reaction (PCR) with the utility of on-field molecular diagnosis and offers a convenient alternative to conventional PCR. In the present study, we developed and evaluated the diagnostic utility of in house LAMP PCR targeting the Brucella genus-specific bcsp-31 gene in patients having febrile illness. MATERIALS AND METHODS: The analytical sensitivity and specificity of bcsp-31 LAMP PCR was first evaluated using brucella (n â€‹= â€‹8) and non-brucella cultures (n â€‹= â€‹5), along with spiked clinical samples. The overall diagnostic utility of developed LAMP PCR was then further evaluated in 393 human samples suspected of brucellosis. RESULTS: The developed LAMP PCR could detect as low as 8 â€‹fg of DNA by visual detection within 35min. We report sensitivity and specificity of the developed LAMP PCR as 90.91% and 99.37%.The accuracy of the developed test assay was found to be 98.60%. In clinical samples, LAMP gave positivity of 20% with the concordance of 89% with conventional PCR. CONCLUSION: To conclude, a rapid, efficacious, sensitive LAMP PCR targeting the bcsp 31 gene was developed. The existing LAMP PCR can be used as a point of care screening test in various low resource endemic setting in lieu of conventional PCR for estimation of prevalence data, diagnosis and treatment of brucellosis.


Subject(s)
Brucella , Brucellosis , Genes, Bacterial , Polymerase Chain Reaction , Humans , Brucella/classification , Brucella/genetics , Brucellosis/diagnosis , Brucellosis/epidemiology , Brucellosis/microbiology , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Sensitivity and Specificity , Point-of-Care Testing/standards , Molecular Diagnostic Techniques/standards , Reference Standards , Time Factors , Prevalence , Zoonoses/diagnosis , Zoonoses/epidemiology , Zoonoses/microbiology , Limit of Detection
3.
J Clin Microbiol ; 61(6): e0011223, 2023 06 20.
Article in English | MEDLINE | ID: mdl-37222630

ABSTRACT

Treponema pallidum subsp. pallidum is a fastidious spirochete and the etiologic agent of syphilis, a sexually transmitted infection (STI). Syphilis diagnoses and disease staging are based on clinical findings and serologic testing. Moreover, according to most international guidelines, PCR analysis of swab samples from genital ulcers is included in the screening algorithm where possible. It has been suggested that PCR might be omitted from the screening algorithm due to low added value. As an alternative to PCR, IgM serology might be used. In this study, we wanted to establish the added value of PCR and IgM serology for diagnosing primary syphilis. Added value was defined as finding more cases of syphilis, preventing overtreatment, or limiting the extent of partner notification to more recent partners. We found that both PCR and IgM immunoblotting could aid the timely diagnosis of early syphilis in ~24% to 27% of patients. PCR has the greatest sensitivity and can be applied to cases with an ulcer with suspected reinfection or primary infection. In the absence of lesions, the IgM immunoblot could be used. However, the IgM immunoblot has better performance in cases with suspected primary infection than in reinfections. The target population, testing algorithm, time pressures, and costs should determine whether either test provides sufficient value to be implemented in clinical practice.


Subject(s)
Diagnostic Tests, Routine , Immunoglobulin M , Syphilis , Humans , Immunoblotting/standards , Immunoglobulin M/analysis , Polymerase Chain Reaction/standards , Syphilis/diagnosis , Syphilis/immunology , Syphilis/microbiology , Treponema pallidum/genetics , Serologic Tests/standards , Diagnostic Tests, Routine/economics , Diagnostic Tests, Routine/methods , Diagnostic Tests, Routine/standards , Sensitivity and Specificity
4.
Rev. peru. med. exp. salud publica ; 39(3): 302-311, jul.-sep. 2022. tab, graf
Article in Spanish | LILACS | ID: biblio-1410008

ABSTRACT

RESUMEN Objetivos. Evaluar la exactitud de gota gruesa (GG) frente a la reacción en cadena de la polimerasa (PCR) cuantitativa para la malaria asociada al embarazo (MAE). Materiales y métodos. Se realizó una revisión sistemática de pruebas diagnósticas en nueve bases de datos. Se evaluó la calidad metodológica con QUADAS. Se estimó sensibilidad, especificidad, cociente de probabilidad positivo (CPP) y negativo (CPN), razón de odds diagnóstica (ORD) y área bajo la curva ROC. Se determinó la heterogeneidad con el estadístico Q de Der Simonian-Laird y la incertidumbre con el porcentaje de peso de cada estudio sobre el resultado global. Resultados. Se incluyeron diez estudios con 5691 gestantes, 1415 placentas y 84 neonatos. En los estudios con nPCR (PCR anidada) y qPCR (PCR cuantitativa) como estándar, los resultados de exactitud diagnóstica fueron estadísticamente similares, con sensibilidad muy baja (50 y 54%, respectivamente), alta especificidad (99% en ambos casos), alto CPP y deficiente CPN. Usando nPCR la OR diagnóstica fue 162 (IC95%=66-401) y el área bajo la curva ROC fue 95%, mientras que con qPCR fueron 231 (IC95%=27-1951) y 78%, respectivamente. Conclusiones. Mediante un protocolo exhaustivo se demostró el bajo desarrollo de investigaciones sobre la exactitud diagnóstica de la GG en MAE. Se demostró que la microscopía tiene un desempeño deficiente para el diagnóstico de infecciones asintomáticas o de baja parasitemia, lo que afianza la importancia de implementar otro tipo de técnicas en el seguimiento y control de las infecciones por malaria en las gestantes, con el fin de lograr el control y posible eliminación de la MAE.


ABSTRACT Objective. To evaluate the accuracy of thick smear (TS) versus quantitative polymerase chain reaction (PCR) for pregnancy-associated malaria (PAM). Materials and methods. We carried out a systematic review of diagnostic tests in nine databases. Methodological quality was evaluated with QUADAS. Sensitivity, specificity, positive likelihood ratio (PLR), negative likelihood ratio (NLR), diagnostic odds ratio (DOR) and area under the ROC curve were estimated. Heterogeneity was determined with the Der Simonian-Laird Q method and uncertainty with the weighted percentage of each study on the overall result. Results. We included 10 studies with 5691 pregnant women, 1415 placentas and 84 neonates. In the studies with nested PCR (nPCR) and quantitative PCR (qPCR) as the standard, the diagnostic accuracy results were statistically similar, with very low sensitivity (50 and 54%, respectively), high specificity (99% in both cases), high PLR and poor NLR. When nPCR was used, the DOR was 162 (95%CI=66-401) and the area under the ROC curve was 95%, while with qPCR it was 231 (95%CI=27-1951) and 78%, respectively. Conclusions. We demonstrated that research on the diagnostic accuracy of TS in PAM is limited. Microscopy showed poor performance in the diagnosis of asymptomatic or low parasitemia infections, which reinforces the importance of implementing other types of techniques for the follow-up and control of malaria infections in pregnant women, in order to achieve the control and possible elimination of PAM.


Subject(s)
Humans , Female , Pregnancy , Infant, Newborn , Polymerase Chain Reaction/standards , Pregnancy Complications, Parasitic/diagnosis , Diagnostic Techniques and Procedures/standards , Malaria/diagnosis , Placenta/parasitology , Meta-Analysis as Topic , Sensitivity and Specificity , Pregnancy Complications, Parasitic/parasitology
5.
Int J Mol Sci ; 23(2)2022 Jan 14.
Article in English | MEDLINE | ID: mdl-35055086

ABSTRACT

Chimeric-antigen-receptor (CAR)-T-cell therapy is already widely used to treat patients who are relapsed or refractory to chemotherapy, antibodies, or stem-cell transplantation. Multiple myeloma still constitutes an incurable disease. CAR-T-cell therapy that targets BCMA (B-cell maturation antigen) is currently revolutionizing the treatment of those patients. To monitor and improve treatment outcomes, methods to detect CAR-T cells in human peripheral blood are highly desirable. In this study, three different detection reagents for staining BCMA-CAR-T cells by flow cytometry were compared. Moreover, a quantitative polymerase chain reaction (qPCR) to detect BCMA-CAR-T cells was established. By applying a cell-titration experiment of BCMA-CAR-T cells, both methods were compared head-to-head. In flow-cytometric analysis, the detection reagents used in this study could all detect BCMA-CAR-T cells at a similar level. The results of false-positive background staining differed as follows (standard deviation): the BCMA-detection reagent used on the control revealed a background staining of 0.04% (±0.02%), for the PE-labeled human BCMA peptide it was 0.25% (±0.06%) and for the polyclonal anti-human IgG antibody it was 7.2% (±9.2%). The ability to detect BCMA-CAR-T cells down to a concentration of 0.4% was similar for qPCR and flow cytometry. The qPCR could detect even lower concentrations (0.02-0.01%). In summary, BCMA-CAR-T-cell monitoring can be reliably performed by both flow cytometry and qPCR. In flow cytometry, reagents with low background staining should be preferred.


Subject(s)
B-Cell Maturation Antigen/metabolism , Flow Cytometry , Polymerase Chain Reaction , Receptors, Chimeric Antigen/metabolism , T-Lymphocytes/metabolism , B-Cell Maturation Antigen/genetics , Biomarkers , Flow Cytometry/methods , Flow Cytometry/standards , Humans , Immunophenotyping , Immunotherapy, Adoptive/methods , Immunotherapy, Adoptive/standards , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Real-Time Polymerase Chain Reaction , Receptors, Chimeric Antigen/genetics , Reproducibility of Results , Sensitivity and Specificity , T-Lymphocytes/immunology
7.
J. venom. anim. toxins incl. trop. dis ; 28: e20210099, 2022. tab, graf
Article in English | LILACS, VETINDEX | ID: biblio-1375813

ABSTRACT

Background: The intrinsic sensitivity limitations of basic parasitological methods, along with the particular biological characteristics of parasites, make these methods ineffective to differentiate morphologically indistinguishable species. Molecular detection and characterization techniques could be used to overcome these problems. The purpose of this work was to standardize molecular polymerase chain reaction (PCR) techniques, described in the literature, for the detection and molecular characterization of intestinal protozoa and other pathogens in humans. Methods: DNA was extracted from human or animal feces, previously washed or cultured in Boeck Drbohlav's Modified Medium. DNA extraction was performed with Machery-Nagel extraction kits. The standardization of the PCR, nested-PCR or RFLP techniques was carried out according to the literature. For each molecular technique performed, the sensitivity of the test was determined based on the minimun quantity required of DNA (sensitivity A) and the minimum quantity of life forms that the test detected (sensitivity B). Results: Sensitivity A was 10 fg for G. duodenalis, 12.5 pg for Entamoeba histolytica or Entamoeba dispar, 50 fg for Cryptosporidium spp., 225 pg for Cyclospora spp. and 800 fg or 8 fg for Blastocystis spp. after performing a 1780 bp PCR or 310 bp nested PCR, respectively. The sensitivity B was 100 cysts for G. duodenalis, 500 cysts for E. histolytica or E. dispar, 1000 oocysts for Cyclospora spp. and 3600 or four vegetatives forms for PCR or nested PCR of Blastocystis spp., respectively. Conclusions: The molecular detection of protozoa and chromist was achieved and the molecular characterization allowed the genotyping of some of the parasites such as Giardia duodenalis, Cryptosporidium spp., and Blastocystis spp. This study summarizes the molecular techniques for epidemiological studies in humans and animals, and helps in the investigation of their transmission sources in countries where intestinal parasites are a public health problem.(AU)


Subject(s)
Humans , Animals , Polymerase Chain Reaction/standards , Intestinal Diseases, Parasitic/diagnosis , Intestines/parasitology , Polymorphism, Restriction Fragment Length , Epidemiologic Studies , Giardia lamblia , Blastocystis , Cryptosporidium
8.
BMC Microbiol ; 21(1): 349, 2021 12 18.
Article in English | MEDLINE | ID: mdl-34922460

ABSTRACT

BACKGROUND: One limiting factor of short amplicon 16S rRNA gene sequencing approaches is the use of low DNA amounts in the amplicon generation step. Especially for low-biomass samples, insufficient or even commonly undetectable DNA amounts can limit or prohibit further analysis in standard protocols. RESULTS: Using a newly established protocol, very low DNA input amounts were found sufficient for reliable detection of bacteria using 16S rRNA gene sequencing compared to standard protocols. The improved protocol includes an optimized amplification strategy by using a digital droplet PCR. We demonstrate how PCR products are generated even when using very low concentrated DNA, unable to be detected by using a Qubit. Importantly, the use of different 16S rRNA gene primers had a greater effect on the resulting taxonomical profiles compared to using high or very low initial DNA amounts. CONCLUSION: Our improved protocol takes advantage of ddPCR and allows faithful amplification of very low amounts of template. With this, samples of low bacterial biomass become comparable to those with high amounts of bacteria, since the first and most biasing steps are the same. Besides, it is imperative to state DNA concentrations and volumes used and to include negative controls indicating possible shifts in taxonomical profiles. Despite this, results produced by using different primer pairs cannot be easily compared.


Subject(s)
Biomass , Polymerase Chain Reaction/methods , RNA, Ribosomal, 16S/genetics , Sequence Analysis, DNA/methods , Bacteria/classification , Bacteria/genetics , Bacteria/isolation & purification , Bias , DNA, Bacterial/analysis , DNA, Bacterial/genetics , Feces/microbiology , High-Throughput Nucleotide Sequencing/methods , High-Throughput Nucleotide Sequencing/standards , Humans , Limit of Detection , Microbiota/genetics , Polymerase Chain Reaction/standards , Reproducibility of Results , Sequence Analysis, DNA/standards , Water Microbiology
9.
PLoS One ; 16(11): e0260082, 2021.
Article in English | MEDLINE | ID: mdl-34843501

ABSTRACT

Quantifying pathogenic genes with q-PCR in complex samples to determine the pathogen loads is influenced by a wide range of factors, including choice of extraction method, standard curve, and the decision to use relative versus absolute quantification of the genes. The aim was to investigate the standardisation of q-PCR methods to determine enumerated E. coli gene ratios grown with the IDEXX Colilert® Quanti-Trays® using enteropathogenic E. coli as the model pathogen. q-PCR targeting the eaeA and gadAB genes was used to calculate the eaeA: gadAB ratios for clinical strains collected between [2005-2006 (n = 55)] and [2008-2009 (n = 19)] using the LinRegPCR software and Corbett Research Thermal cycler software. Both programs grouped the isolates into two distinct groups based on the gene ratios although the Corbett Research Thermal cycler software gave results one log higher than the LinRegPCR program. Although the eaeA: gadAB ratio range was determined using extracted E. coli DNA, the impact of free DNA and other bacteria present in the sample needed to be understood. Standard curve variations using serially diluted extracted E. coli DNA, serially diluted pure E. coli culture followed by DNA extraction from each dilution with or without other bacteria was tested using the eaeA q-PCR to quantify the genes. Comparison of the standard curves showed no significant difference between standard curves prepared with diluted DNA or with cells diluted before the DNA is extracted (P = 0.435). Significant differences were observed when background DNA was included in the diluent or Coliform cells added to the diluent to dilute cells before the DNA is extracted (P < 0.001). The "carrier" DNA and Coliform cells enhanced the DNA extraction results resulting in better PCR efficiency. This will have an influence on the quantification of gene ratios and pathogen load in samples containing lower numbers of E. coli.


Subject(s)
Escherichia coli/genetics , Escherichia coli/metabolism , Genes, Essential/genetics , Environmental Monitoring/methods , Escherichia coli/pathogenicity , Escherichia coli Proteins/genetics , Gene Expression Profiling/methods , Humans , Nucleic Acid Amplification Techniques/standards , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Transcriptome/genetics , Virulence/genetics
10.
Sci Rep ; 11(1): 22384, 2021 11 17.
Article in English | MEDLINE | ID: mdl-34789731

ABSTRACT

SuperSelective primers, by virtue of their unique design, enable the selective exponential amplification of rare DNA fragments containing somatic mutations in the presence of abundant closely related wild-type DNA fragments. However, when a SuperSelective primer is used in conjunction with a conventional reverse primer, linear amplification of the abundant wild-type fragments occurs, and this may lead to a late arising signal that can be confused with the late arising signal from the rare mutant fragments. We have discovered that the use of a pair of SuperSelective primers, one specific for the target mutation in a plus strand, and the other specific for the same mutation in the complementary minus strand, but both possessing 3'-terminal nucleotides that are complementary to the mutation, significantly suppresses the linear amplification of the related wild-type sequence, and prevents the generation of false mutant sequences due to mis-incorporation by the DNA polymerase. As a consequence, the absence of mutant fragments in a sample does not give rise to a false-positive signal, and the presence of mutant fragments in a sample is clearly distinguishable as a true-positive signal. The use of SuperSelective primer pairs should enhance the sensitivity of multiplex PCR assays that identify and quantitate somatic mutations in liquid biopsies obtained from patients with cancer, thereby enabling the choice of a targeted therapy, the determination of its effectiveness over time, and the substitution of a more appropriate therapy as new mutations arise.


Subject(s)
DNA Mutational Analysis/methods , DNA Primers , Mutation , Polymerase Chain Reaction , Alleles , DNA Mutational Analysis/standards , Gene Frequency , Humans , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Sensitivity and Specificity
11.
Am J Trop Med Hyg ; 106(1): 312-319, 2021 10 18.
Article in English | MEDLINE | ID: mdl-34662861

ABSTRACT

Human strongyloidiasis is one of the neglected tropical diseases caused by infection with soil-transmitted helminth Strongyloides stercoralis. Conventional stool examination, a method commonly used for diagnosis of S. stercoralis, has low sensitivity, especially in the case of light infections. Herein, we developed the droplet digital polymerase chain reaction (ddPCR) assay to detect S. stercoralis larvae in stool and compared its performance with real-time PCR and stool examination techniques (formalin ethyl-acetate concentration technique [FECT] and agar plate culture [APC]). The ddPCR results showed 98% sensitivity and 90% specificity, and real-time PCR showed 82% sensitivity and 76.7% specificity when compared with the microscopic methods. Moreover, ddPCR could detect a single S. stercoralis larva in feces, and cross-reactions with other parasites were not observed. In conclusion, a novel ddPCR method exhibited high sensitivity and specificity for detection of S. stercoralis in stool samples. This technique may help to improve diagnosis, particularly in cases with light infection. In addition, ddPCR technique might be useful for screening patients before starting immunosuppressive drug therapy, and follow-up after treatment of strongyloidiasis.


Subject(s)
Feces/parasitology , Polymerase Chain Reaction/standards , Strongyloides stercoralis/isolation & purification , Strongyloidiasis/diagnosis , Strongyloidiasis/parasitology , Animals , Cross Reactions , Polymerase Chain Reaction/methods , Strongyloides stercoralis/genetics
13.
Pharmacogenomics ; 22(16): 1041-1056, 2021 11.
Article in English | MEDLINE | ID: mdl-34693729

ABSTRACT

Aim: The clinical utility of pharmacogenomics (PGx) has been gaining traction alongside growing evidence that adverse drug reactions (ADRs) have significant genetic associations. Nala PGx Core® is a multi-gene qPCR-based panel of 20 allele variants, comprising 18 SNPs and two CYP2D6 copy number markers across four pharmacogenes - CYP2C9, CYP2C19, CYP2D6 and SLCO1B1. Methods: In this study, we validated the performance of Nala PGx Core® against benchmark methods, on the Singaporean and Indonesian populations. Results & conclusion: Nala PGx Core® demonstrated robust and accurate genotyping when compared with other established benchmarks. Furthermore, the panel successfully characterized alleles of clinical relevance, such as CYP2D6*10 and CYP2D6*36, across major ethnic groups present of Singapore and Indonesia, suggesting its potential for adoption in clinical workflows regionally.


Subject(s)
Pharmacogenetics/methods , Polymerase Chain Reaction/standards , Algorithms , Asian People , Benchmarking , Cytochrome P-450 CYP2C19 , Cytochrome P-450 CYP2D6/genetics , Drug-Related Side Effects and Adverse Reactions/genetics , Ethnicity , Gene Dosage , Genotype , Humans , Indonesia , Polymorphism, Single Nucleotide , Reproducibility of Results , Singapore
14.
Nucleic Acids Res ; 49(20): e120, 2021 11 18.
Article in English | MEDLINE | ID: mdl-34534325

ABSTRACT

ΩqPCR determines absolute telomere length in kb units from single cells. Accuracy and precision of ΩqPCR were assessed using 800 bp and 1600 bp synthetic telomeres inserted into plasmids, which were measured to be 819 ± 19.6 and 1590 ± 42.3 bp, respectively. This is the first telomere length measuring method verified in this way. The approach uses Ω-probes, a DNA strand containing sequence information that enables: (i) hybridization with the telomere via the 3' and 5' ends that become opposed; (ii) ligation of the hybridized probes to circularize the Ω-probes and (iii) circularized-dependent qPCR due to sequence information for a forward primer, and for a reverse primer binding site, and qPCR hydrolysis probe binding. Read through of the polymerase during qPCR occurs only in circularized Ω-probes, which quantifies their number that is directly proportional to telomere length. When used in concert with information about the cell cycle stage from a single-copy gene, and ploidy, the MTL of single cells measured by ΩqPCR was consistent with that obtained from large sample sizes by TRF.


Subject(s)
Polymerase Chain Reaction/methods , Single-Cell Analysis/methods , Telomere Homeostasis , Telomere/chemistry , Cell Line , Humans , Limit of Detection , Polymerase Chain Reaction/standards , Single-Cell Analysis/standards , Telomere/genetics
15.
Exp Parasitol ; 230: 108157, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34543651

ABSTRACT

Strongyloides venezuelensis has been used in different experimental studies, such as those aimed at the evaluation of diagnostic techniques for human strongyloidiasis, mainly the molecular diagnosis. In this study, three regions (genus, 18S and 28S targets) of Strongyloides ribosomal DNA were evaluated for the molecular diagnosis of experimental strongyloidiasis. Rats were infected subcutaneously with 400 or 4000 S. venezuelensis infective larvae (400iL3 and 4000iL3), and kept for 35 days. Fecal samples were collected daily to count eggs per gram of feces (EPG) and to perform the polymerase chain reaction (PCR). Egg count started on the 5th day post-infection (pi) and ended on days 33 and 34 pi, in 400iL3 and 4000iL3 groups, respectively. Based in EPG, fecal samples were selected from days 2, 5, 8, 11, 15, 23 and 35 pi for DNA extraction; PCR (genus, 18S and 28S); and sequencing. The PCR-28S products showed higher values of identity (95-100%) in the database with the Strongyloides sequences. Therefore, it is possible to reinforce the application of PCR-28S in the diagnosis of experimental and human strongyloidiasis.


Subject(s)
DNA, Ribosomal/genetics , RNA, Ribosomal, 18S/genetics , RNA, Ribosomal, 28S/genetics , Strongyloides/genetics , Strongyloidiasis/diagnosis , Animals , DNA, Helminth/genetics , DNA, Helminth/isolation & purification , DNA, Ribosomal/isolation & purification , Feces/parasitology , Humans , Larva/genetics , Male , Parasite Egg Count , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Rats , Rats, Wistar , Sensitivity and Specificity , Strongyloides/pathogenicity
16.
Parasit Vectors ; 14(1): 473, 2021 Sep 15.
Article in English | MEDLINE | ID: mdl-34526109

ABSTRACT

BACKGROUND: In characterizing malaria epidemiology, measuring mosquito infectiousness informs the entomological inoculation rate, an important metric of malaria transmission. PCR-based methods have been touted as more sensitive than the current "gold-standard" circumsporozoite (CSP) ELISA. Wider application of PCR-based methods has been limited by lack of specificity for the infectious sporozoite stage. We compared a PCR method for detecting the parasite's mitochondrial (mt) cytochrome oxidase I (COX-I) gene with ELISA for detecting circumsporozoite protein for identification of different life stages of the parasite during development within a mosquito. METHODS: A PCR-based method targeting the Plasmodium mt COX-I gene was compared with the CSP ELISA method to assess infectivity in Anopheles arabiensis colony mosquitoes fed on blood from patients infected with Plasmodium vivax. Mosquitoes were tested at six post-infection time points (days 0.5, 1, 6, 9, 12, 15). The head and thorax and the abdomen for each specimen were tested separately with each method. Agreement between methods at each infection stage was measured using Cohen's kappa measure of test association. RESULTS: Infection status of mosquitoes was assessed in approximately 90 head/thorax and 90 abdomen segments at each time point; in total, 538 head/thorax and 534 abdomen segments were tested. In mosquitoes bisected after 0.5, 1, and 6 days post-infection (dpi), the mt COX-I PCR detected Plasmodium DNA in both the abdomen (88, 78, and 67%, respectively) and head/thorax segments (69, 60, and 44%, respectively), whilst CSP ELISA detected sporozoites in only one abdomen on day 6 post-infection. PCR was also more sensitive than ELISA for detection of Plasmodium in mosquitoes bisected after 9, 12, and 15 dpi in both the head and thorax and abdomen. There was fair agreement between methods for time points 9-15 dpi (κ = 0.312, 95% CI: 0.230-0.394). CONCLUSIONS: The mt COX-I PCR is a highly sensitive, robust method for detecting Plasmodium DNA in mosquitoes, but its limited Plasmodium life-stage specificity cannot be overcome by bisection of the head and thorax from the abdomen prior to PCR. Thus, the mt COX-I PCR is a poor candidate for identifying infectious mosquitoes.


Subject(s)
Anopheles/parasitology , Enzyme-Linked Immunosorbent Assay/standards , Life Cycle Stages/genetics , Plasmodium vivax/genetics , Polymerase Chain Reaction/standards , Sporozoites/genetics , Animals , Enzyme-Linked Immunosorbent Assay/methods , Female , Plasmodium vivax/immunology , Polymerase Chain Reaction/methods , Sporozoites/immunology
17.
Viruses ; 13(9)2021 08 28.
Article in English | MEDLINE | ID: mdl-34578293

ABSTRACT

The SARS-CoV-2 pandemic has required the development of multiple testing systems to monitor and control the viral infection. Here, we developed a PCR test to screen COVID-19 infections that can process up to ~180 samples per day without the requirement of robotics. For this purpose, we implemented the use of multichannel pipettes and plate magnetics for the RNA extraction step and combined the reverse transcription with the qPCR within one step. We tested the performance of two RT-qPCR kits as well as different sampling buffers and showed that samples taken in NaCl or PBS are stable and compatible with different COVID-19 testing systems. Finally, we designed a new internal control based on the human RNase P gene that does not require a DNA digestion step. Our protocol is easy to handle and reaches the sensitivity and accuracy of the standardized diagnostic protocols used in the clinic to detect COVID-19 infections.


Subject(s)
COVID-19 Nucleic Acid Testing/methods , COVID-19/diagnosis , COVID-19/virology , Polymerase Chain Reaction , SARS-CoV-2 , COVID-19 Nucleic Acid Testing/standards , Humans , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Reagent Kits, Diagnostic , Real-Time Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/standards , Reproducibility of Results , SARS-CoV-2/genetics , Sensitivity and Specificity , Viral Load
18.
Sci Rep ; 11(1): 17148, 2021 08 25.
Article in English | MEDLINE | ID: mdl-34433845

ABSTRACT

The low biomass of respiratory samples makes it difficult to accurately characterise the microbial community composition. PCR conditions and contaminating microbial DNA can alter the biological profile. The objective of this study was to benchmark the currently available laboratory protocols to accurately analyse the microbial community of low biomass samples. To study the effect of PCR conditions on the microbial community profile, we amplified the 16S rRNA gene of respiratory samples using various bacterial loads and different number of PCR cycles. Libraries were purified by gel electrophoresis or AMPure XP and sequenced by V2 or V3 MiSeq reagent kits by Illumina sequencing. The positive control was diluted in different solvents. PCR conditions had no significant influence on the microbial community profile of low biomass samples. Purification methods and MiSeq reagent kits provided nearly similar microbiota profiles (paired Bray-Curtis dissimilarity median: 0.03 and 0.05, respectively). While profiles of positive controls were significantly influenced by the type of dilution solvent, the theoretical profile of the Zymo mock was most accurately analysed when the Zymo mock was diluted in elution buffer (difference compared to the theoretical Zymo mock: 21.6% for elution buffer, 29.2% for Milli-Q, and 79.6% for DNA/RNA shield). Microbiota profiles of DNA blanks formed a distinct cluster compared to low biomass samples, demonstrating that low biomass samples can accurately be distinguished from DNA blanks. In summary, to accurately characterise the microbial community composition we recommend 1. amplification of the obtained microbial DNA with 30 PCR cycles, 2. purifying amplicon pools by two consecutive AMPure XP steps and 3. sequence the pooled amplicons by V3 MiSeq reagent kit. The benchmarked standardized laboratory workflow presented here ensures comparability of results within and between low biomass microbiome studies.


Subject(s)
Benchmarking/methods , Microbiota , Reagent Kits, Diagnostic/standards , Respiratory Mucosa/microbiology , Biomass , Humans , Metagenomics/methods , Metagenomics/standards , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , RNA, Ribosomal, 16S/genetics , Saliva/microbiology
19.
Sci Rep ; 11(1): 17171, 2021 08 25.
Article in English | MEDLINE | ID: mdl-34433869

ABSTRACT

Advances in whole genome amplification (WGA) techniques enable understanding of the genomic sequence at a single cell level. Demand for single cell dedicated WGA kits (scWGA) has led to the development of several commercial kit. To this point, no robust comparison of all available kits was performed. Here, we benchmark an economical assay, comparing all commercially available scWGA kits. Our comparison is based on targeted sequencing of thousands of genomic loci, including highly mutable regions, from a large cohort of human single cells. Using this approach we have demonstrated the superiority of Ampli1 in genome coverage and of RepliG in reduced error rate. In summary, we show that no single kit is optimal across all categories, highlighting the need for a dedicated kit selection in accordance with experimental requirements.


Subject(s)
Single-Cell Analysis/methods , Whole Genome Sequencing/methods , Cells, Cultured , Humans , Polymerase Chain Reaction/methods , Polymerase Chain Reaction/standards , Sensitivity and Specificity , Single-Cell Analysis/standards , Whole Genome Sequencing/standards
20.
Malar J ; 20(1): 340, 2021 Aug 12.
Article in English | MEDLINE | ID: mdl-34384431

ABSTRACT

BACKGROUND: Emergence of Plasmodium falciparum resistance to artemisinin and its derivatives poses a threat to the global effort to control malaria. The emergence of anti-malarial resistance has become a great public health challenge and continues to be a leading threat to ongoing malaria control efforts. The aim of this review was to synthesize available evidence on the efficacy of dihydroartemisinin-piperaquine (DHA-PQ) compared to artemether-lumefantrine (AL) for the treatment of uncomplicated falciparum malaria among children in Africa. METHODS: A systematic literature search was done to identify relevant articles from online databases PubMed/ MEDLINE, Embase, and Cochrane Central Register of Controlled Trials' database (CENTRAL) for retrieving randomized control trials comparing efficacy of DHA-PQ and AL for treatment of uncomplicated falciparum malaria in African children. The search was performed from August 2020 to April 2021. Using Rev-Man software (V5.4.1), R-studio and Comprehensive Meta-analysis software version 3, the extracted data from eligible studies were pooled as risk ratio (RR) with 95% confidence interval (CI). RESULTS: In this review, 25 studies which involved a total of 13,198 participants were included. PCR-unadjusted treatment failure in children aged between 6 months and 15 years was significantly lower in the DHA-PQ treatment arm on day 28 than that of AL (RR 0.14, 95% CI 0.08-0.26; participants = 1302; studies = 4; I2 = 0%, high quality of evidence). Consistently, the PCR-adjusted treatment failure was significantly lower with DHA-PQ treatment group on day 28 (RR 0.45, 95% CI 0.29-0.68; participants = 8508; studies = 16; I2 = 51%, high quality of evidence) and on day 42 (RR 0.60, 95% CI 0.47-0.78; participants = 5959; studies = 17; I2 = 0%, high quality of evidence). However, the efficacy was ≥ 95% in both treatment groups on day 28. CONCLUSION: From this review, it can be concluded that DHA-PQ reduces new infection and recrudescence on days 28 and 42 more than AL. This may trigger DHA-PQ to become a first-line treatment option.


Subject(s)
Antimalarials/therapeutic use , Artemether, Lumefantrine Drug Combination/therapeutic use , Artemisinins/therapeutic use , Malaria, Falciparum/drug therapy , Quinolines/therapeutic use , Adolescent , Africa , Antimalarials/administration & dosage , Artemisinins/administration & dosage , Child , Child, Preschool , Drug Combinations , Humans , Infant , Polymerase Chain Reaction/standards , Quality Control , Quinolines/administration & dosage , Randomized Controlled Trials as Topic , Regression Analysis , Sensitivity and Specificity , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...