Results 1 - 20 de 1.914
Filter
1.
Medicine (Baltimore) ; 103(19): e38089, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38728501

ABSTRACT

Proton beam therapy (PBT) has great advantages as tumor radiotherapy and is progressively becoming a more prevalent choice for individuals undergoing radiation therapy. The objective of this review is to pinpoint collaborative efforts among countries and institutions, while also exploring the hot topics and future outlook in the field of PBT. Data from publications were downloaded from the Web of Science Core Collection. CiteSpace and Excel 2016 were used to conduct the bibliometric and knowledge map analysis. A total of 6516 publications were identified, with the total number of articles steadily increasing and the United States being the most productive country. Harvard University took the lead in contributing the highest number of publications. Paganetti Harald published the most articles and had the most cocitations. PHYS MED BIOL published the greatest number of PBT-related articles, while INT J RADIAT ONCOL received the most citations. Paganetti Harald, 2012, PHYS MED BIOL can be classified as classic literature due to its high citation rate. We believe that research on technology development, dose calculation and relative biological effectiveness were the knowledge bases in this field. Future research hotspots may include clinical trials, flash radiotherapy, and immunotherapy.


Subject(s)
Bibliometrics , Proton Therapy , Proton Therapy/statistics & numerical data , Proton Therapy/methods , Humans , Biomedical Research/statistics & numerical data , Neoplasms/radiotherapy
2.
Sci Rep ; 14(1): 10637, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38724569

ABSTRACT

Hadron therapy is an advanced radiation modality for treating cancer, which currently uses protons and carbon ions. Hadrons allow for a highly conformal dose distribution to the tumour, minimising the detrimental side-effects due to radiation received by healthy tissues. Treatment with hadrons requires sub-millimetre spatial resolution and high dosimetric accuracy. This paper discusses the design, fabrication and performance tests of a detector based on Gas Electron Multipliers (GEM) coupled to a matrix of thin-film transistors (TFT), with an active area of 60 × 80 mm2 and 200 ppi resolution. The experimental results show that this novel detector is able to detect low-energy (40 kVp X-rays), high-energy (6 MeV) photons used in conventional radiation therapy and protons and carbon ions of clinical energies used in hadron therapy. The GEM-TFT is a compact, fully scalable, radiation-hard detector that measures secondary electrons produced by the GEMs with sub-millimetre spatial resolution and a linear response for proton currents from 18 pA to 0.7 nA. Correcting known detector defects may aid in future studies on dose uniformity, LET dependence, and different gas mixture evaluation, improving the accuracy of QA in radiotherapy.


Subject(s)
Radiometry , Radiometry/instrumentation , Radiometry/methods , Humans , Radiotherapy/methods , Radiotherapy/standards , Radiotherapy/instrumentation , Quality Assurance, Health Care , Electrons , Radiotherapy Dosage , Neoplasms/radiotherapy , Equipment Design , Proton Therapy/instrumentation , Proton Therapy/methods
3.
Radiat Oncol ; 19(1): 56, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745333

ABSTRACT

BACKGROUND: Oncologic surgical resection is the standard of care for extremity and truncal soft tissue sarcoma (STS), often accompanied by the addition of pre- or postoperative radiation therapy (RT). Preoperative RT may decrease the risk of joint stiffness and fibrosis at the cost of higher rates of wound complications. Hypofractionated, preoperative RT has been shown to provide acceptable outcomes in prospective trials. Proton beam therapy (PBT) provides the means to decrease dose to surrounding organs at risk, such as the skin, bone, soft tissues, and adjacent joint(s), and has not yet been studied in patients with extremity and truncal sarcoma. METHODS: Our study titled "PROspective phase II trial of preoperative hypofractionated protoN therapy for extremity and Truncal soft tissue sarcOma (PRONTO)" is a non-randomized, prospective phase II trial evaluating the safety and efficacy of preoperative, hypofractionated PBT for patients with STS of the extremity and trunk planned for surgical resection. Adult patients with Eastern Cooperative Group Performance Status ≤ 2 with resectable extremity and truncal STS will be included, with the aim to accrue 40 patients. Treatment will consist of 30 Gy radiobiological equivalent of PBT in 5 fractions delivered every other day, followed by surgical resection 2-12 weeks later. The primary outcome is rate of major wound complications as defined according to the National Cancer Institute of Canada Sarcoma2 (NCIC-SR2) Multicenter Trial. Secondary objectives include rate of late grade ≥ 2 toxicity, local recurrence-free survival and distant metastasis-free survival at 1- and 2-years, functional outcomes, quality of life, and pathologic response. DISCUSSION: PRONTO represents the first trial evaluating the use of hypofractionated PBT for STS. We aim to prove the safety and efficacy of this approach and to compare our results to historical outcomes established by previous trials. Given the low number of proton centers and limited availability, the short course of PBT may provide the opportunity to treat patients who would otherwise be limited when treating with daily RT over several weeks. We hope that this trial will lead to increased referral patterns, offer benefits towards patient convenience and clinic workflow efficiency, and provide evidence supporting the use of PBT in this setting. TRIAL REGISTRATION: NCT05917301 (registered 23/6/2023).


Subject(s)
Extremities , Proton Therapy , Radiation Dose Hypofractionation , Sarcoma , Humans , Proton Therapy/methods , Sarcoma/radiotherapy , Sarcoma/pathology , Prospective Studies , Adult , Female , Male , Soft Tissue Neoplasms/radiotherapy , Soft Tissue Neoplasms/pathology , Soft Tissue Neoplasms/surgery , Preoperative Care , Torso
4.
Neurosurg Focus ; 56(5): E9, 2024 May.
Article in English | MEDLINE | ID: mdl-38691864

ABSTRACT

OBJECTIVE: Chordomas are rare tumors of the skull base and spine believed to arise from the vestiges of the embryonic notochord. These tumors are locally aggressive and frequently recur following resection and adjuvant radiotherapy. Proton therapy has been introduced as a tissue-sparing option because of the higher level of precision that proton-beam techniques offer compared with traditional photon radiotherapy. This study aimed to compare recurrence in patients with chordomas receiving proton versus photon radiotherapy following resection by applying tree-based machine learning models. METHODS: The clinical records of all patients treated with resection followed by adjuvant proton or photon radiotherapy for chordoma at Mayo Clinic were reviewed. Patient demographics, type of surgery and radiotherapy, tumor recurrence, and other variables were extracted. Decision tree classifiers were trained and tested to predict long-term recurrence based on unseen data using an 80/20 split. RESULTS: Fifty-three patients with a mean ± SD age of 55.2 ± 13.4 years receiving surgery and adjuvant proton or photon therapy to treat chordoma were identified; most patients were male. Gross-total resection was achieved in 54.7% of cases. Proton therapy was the most common adjuvant radiotherapy (84.9%), followed by conventional or external-beam radiation therapy (9.4%) and stereotactic radiosurgery (5.7%). Patients receiving proton therapy exhibited a 40% likelihood of having recurrence, significantly lower than the 88% likelihood observed in those treated with nonproton therapy. This was confirmed on logistic regression analysis adjusted for extent of tumor resection and tumor location, which revealed that proton adjuvant radiotherapy was associated with a decreased risk of recurrence (OR 0.1, 95% CI 0.01-0.71; p = 0.047) compared with photon therapy. The decision tree algorithm predicted recurrence with an accuracy of 90% (95% CI 55.5%-99.8%), with the lowest risk of recurrence observed in patients receiving gross-total resection with adjuvant proton therapy (23%). CONCLUSIONS: Following resection, adjuvant proton therapy was associated with a lower risk of chordoma recurrence compared with photon therapy. The described machine learning models were able to predict tumor progression based on the extent of tumor resection and adjuvant radiotherapy modality used.


Subject(s)
Chordoma , Neoplasm Recurrence, Local , Photons , Proton Therapy , Spinal Neoplasms , Humans , Chordoma/radiotherapy , Chordoma/surgery , Male , Female , Middle Aged , Neoplasm Recurrence, Local/radiotherapy , Proton Therapy/methods , Radiotherapy, Adjuvant/methods , Adult , Aged , Spinal Neoplasms/radiotherapy , Spinal Neoplasms/surgery , Photons/therapeutic use , Retrospective Studies , Treatment Outcome
5.
Biomed Phys Eng Express ; 10(3)2024 Apr 22.
Article in English | MEDLINE | ID: mdl-38652667

ABSTRACT

Utilising Machine Learning (ML) models to predict dosimetric parameters in pencil beam scanning proton therapy presents a promising and practical approach. The study developed Artificial Neural Network (ANN) models to predict proton beam spot size and relative positional errors using 9000 proton spot data. The irradiation log files as input variables and corresponding scintillation detector measurements as the label values. The ANN models were developed to predict six variables: spot size in thex-axis,y-axis, major axis, minor axis, and relative positional errors in thex-axis andy-axis. All ANN models used a Multi-layer perception (MLP) network using one input layer, three hidden layers, and one output layer. Model performance was validated using various statistical tools. The log file recorded spot size and relative positional errors, which were compared with scintillator-measured data. The Root Mean Squared Error (RMSE) values for the x-spot and y-spot sizes were 0.356 mm and 0.362 mm, respectively. Additionally, the maximum variation for the x-spot relative positional error was 0.910 mm, while for the y-spot, it was 1.610 mm. The ANN models exhibit lower prediction errors. Specifically, the RMSE values for spot size prediction in the x, y, major, and minor axes are 0.053 mm, 0.049 mm, 0.053 mm, and 0.052 mm, respectively. Additionally, the relative spot positional error prediction model for the x and y axes yielded maximum errors of 0.160 mm and 0.170 mm, respectively. The normality of models was validated using the residual histogram and Q-Q plot. The data over fit, and bias were tested using K (k = 5) fold cross-validation, and the maximum RMSE value of the K fold cross-validation among all the six ML models was less than 0.150 mm (R-Square 0.960). All the models showed excellent prediction accuracy. Accurately predicting beam spot size and positional errors enhances efficiency in routine dosimetric checks.


Subject(s)
Neural Networks, Computer , Proton Therapy , Radiometry , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Proton Therapy/methods , Radiometry/methods , Humans , Radiotherapy Planning, Computer-Assisted/methods , Algorithms , Machine Learning , Reproducibility of Results , Protons
6.
Sci Rep ; 14(1): 8468, 2024 04 11.
Article in English | MEDLINE | ID: mdl-38605022

ABSTRACT

Spatially Fractionated Radiotherapy (SFRT) has demonstrated promising potential in cancer treatment, combining the advantages of reduced post-radiation effects and enhanced local control rates. Within this paradigm, proton minibeam radiotherapy (pMBRT) was suggested as a new treatment modality, possibly producing superior normal tissue sparing to conventional proton therapy, leading to improvements in patient outcomes. However, an effective and convenient beam generation method for pMBRT, capable of implementing various optimum dose profiles, is essential for its real-world application. Our study investigates the potential of utilizing the moiré effect in a dual collimator system (DCS) to generate pMBRT dose profiles with the flexibility to modify the center-to-center distance (CTC) of the dose distribution in a technically simple way.We employ the Geant4 Monte Carlo simulations tool to demonstrate that the angle between the two collimators of a DCS can significantly impact the dose profile. Varying the DCS angle from 10 ∘ to 50 ∘ we could cover CTC ranging from 11.8 mm to 2.4 mm, respectively. Further investigations reveal the substantial influence of the multi-slit collimator's (MSC) physical parameters on the spatially fractionated dose profile, such as period (CTC), throughput, and spacing between MSCs. These findings highlight opportunities for precision dose profile adjustments tailored to specific clinical scenarios.The DCS capacity for rapid angle adjustments during the energy transition stages of a spot scanning system can facilitate dynamic alterations in the irradiation profile, enhancing dose contrast in normal tissues. Furthermore, its unique attribute of spatially fractionated doses in both lateral directions could potentially improve normal tissue sparing by minimizing irradiated volume. Beyond the realm of pMBRT, the dual MSC system exhibits remarkable versatility, showing compatibility with different types of beams (X-rays and electrons) and applicability across various SFRT modalities.Our study illuminates the dual MSC system's potential as an efficient and adaptable tool in the refinement of pMBRT techniques. By enabling meticulous control over irradiation profiles, this system may expedite advancements in clinical and experimental applications, thereby contributing to the evolution of SFRT strategies.


Subject(s)
Proton Therapy , Radiation Injuries , Humans , Proton Therapy/methods , Protons , Radiation, Ionizing , Monte Carlo Method , Etoposide , Dose Fractionation, Radiation , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
7.
Hematol Oncol ; 42(3): e3269, 2024 May.
Article in English | MEDLINE | ID: mdl-38650534

ABSTRACT

Classical Hodgkin lymphoma is a lymphoproliferative disease with a good prognosis mainly seen in young people. Nevertheless secondary malignancy, cardiac disease and infertility may affect the long survivors with significant impact on quality of life, morbidity and overall survival. In the last decades several treatment strategies were evaluated to reduce the toxicity of first line treatment such as avoiding radiotherapy or its reduction in terms of dosage and extension. Many trials including interim Positron Emission Tomography evaluation fail to compare efficacy between combined modality treatment versus chemotherapy alone in particular in early stage disease. In this review we analyze which subset of patients could take advantage from proton therapy in terms of toxicity and cost effectiveness.


Subject(s)
Hodgkin Disease , Humans , Hodgkin Disease/radiotherapy , Proton Therapy/adverse effects , Proton Therapy/methods
8.
Anticancer Res ; 44(5): 2219-2230, 2024 May.
Article in English | MEDLINE | ID: mdl-38677752

ABSTRACT

BACKGROUND/AIM: This study aimed to compare the oncological outcomes of proton beam radiotherapy (PBT) with those of radiofrequency ablation (RFA) for newly diagnosed hepatocellular carcinoma (HCC). PATIENTS AND METHODS: This study included 323 patients who underwent PBT (n=40) or RFA (n=283) as a curative treatment for previously untreated HCC between October 2016 and June 2021. The primary endpoints were local progression and toxicity. RESULTS: The median follow-up was 3.4 years (range=1.1-5.7 years). In terms of portal vein tumor thrombosis, tumor size, alpha-fetoprotein, and prothrombin-induced by vitamin K absence-II, the PBT group had significantly more severe tumor burdens than those of the RFA group (p<0.0001, p<0.0001, p=0.0004, and p<0.0001, respectively). No significant difference was observed in cumulative local progression rate (10.4% in PBT vs. 7.8% in RFA at 3-years, p=0.895). Grade 3 or higher toxicity was reported in only one patient (0.4%) after RFA. Multivariable analysis demonstrated that treatment modality was not a significant prognostic factor for local progression (hazard ratio=1.05; 95% confidence interval=0.32-3.48; p=0.934). CONCLUSION: PBT demonstrated comparable local control with acceptable toxicity to RFA in newly diagnosed HCC. Therefore, PBT may be a valid alternative.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Proton Therapy , Radiofrequency Ablation , Humans , Carcinoma, Hepatocellular/radiotherapy , Carcinoma, Hepatocellular/surgery , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/radiotherapy , Liver Neoplasms/pathology , Liver Neoplasms/surgery , Male , Female , Proton Therapy/adverse effects , Proton Therapy/methods , Radiofrequency Ablation/methods , Radiofrequency Ablation/adverse effects , Middle Aged , Aged , Adult , Treatment Outcome , Aged, 80 and over , Retrospective Studies
9.
Cancer Radiother ; 28(2): 195-201, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38599941

ABSTRACT

PURPOSE: Preclinical data demonstrated that the use of proton minibeam radiotherapy reduces the risk of toxicity in healthy tissue. Ventricular tachycardia radioablation is an area under clinical investigation in proton beam therapy. We sought to simulate a ventricular tachycardia radioablation with proton minibeams and to demonstrate that it was possible to obtain a homogeneous coverage of an arrhythmogenic cardiac zone with this technique. MATERIAL AND METHODS: An arrhythmogenic target volume was defined on the simulation CT scan of a patient, localized in the lateral wall of the left ventricle. A dose of 25Gy was planned to be delivered by proton minibeam radiotherapy, simulated using a Monte Carlo code (TOPAS v.3.7) with a collimator of 19 0.4 mm-wide slits spaced 3mm apart. The main objective of the study was to obtain a plan ensuring at least 93% of the prescription dose in 93% of the planning target volume without exceeding 110% of the prescribed dose in the planning target volume. RESULTS: The average dose in the planning treatment volume in proton minibeam radiotherapy was 25.12Gy. The percentage of the planning target volume receiving 93% (V93%), 110% (V110%), and 95% (V95%) of the prescribed dose was 94.25%, 0%, and 92.6% respectively. The lateral penumbra was 6.6mm. The mean value of the peak-to-valley-dose ratio in the planning target volume was 1.06. The mean heart dose was 2.54Gy versus 5.95Gy with stereotactic photon beam irradiation. CONCLUSION: This proof-of-concept study shows that proton minibeam radiotherapy can achieve a homogeneous coverage of an arrhythmogenic cardiac zone, reducing the dose at the normal tissues. This technique, ensuring could theoretically reduce the risk of late pulmonary and breast fibrosis, as well as cardiac toxicity as seen in previous biological studies in proton minibeam radiotherapy.


Subject(s)
Proton Therapy , Protons , Humans , Feasibility Studies , Proton Therapy/methods , Radiometry , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Monte Carlo Method
10.
Crit Rev Oncog ; 29(3): 67-82, 2024.
Article in English | MEDLINE | ID: mdl-38683154

ABSTRACT

Given the radiobiological and physical properties of the proton, proton beam therapy has the potential to be advantageous for many patients compared with conventional radiotherapy by limiting toxicity and improving patient outcomes in specific breast cancer scenarios.


Subject(s)
Breast Neoplasms , Proton Therapy , Humans , Breast Neoplasms/radiotherapy , Proton Therapy/methods , Female , Protons
11.
Sci Rep ; 14(1): 8193, 2024 04 08.
Article in English | MEDLINE | ID: mdl-38589544

ABSTRACT

The study aimed to determine the specific relative biological effectiveness (RBE) of various cells in the hippocampus following proton irradiation. Sixty Sprague-Dawley rats were randomly allocated to 5 groups receiving 20 or 30 Gy of proton or photon irradiation. Pathomorphological neuronal damage in the hippocampus was assessed using Hematoxylin-eosin (HE) staining. The expression level of NeuN, Nestin, Caspase-3, Olig2, CD68 and CD45 were determined by immunohistochemistry (IHC). The RBE range established by comparing the effects of proton and photon irradiation at equivalent biological outcomes. Proton20Gy induced more severe damage to neurons than photon20Gy, but showed no difference compared to photon30Gy. The RBE of neuron was determined to be 1.65. Similarly, both proton20Gy and proton30Gy resulted in more inhibition of oligodendrocytes and activation of microglia in the hippocampal regions than photon20Gy and photon30Gy. However, the expression of Olig2 was higher and CD68 was lower in the proton20Gy group than in the photon30Gy group. The RBE of oligodendrocyte and microglia was estimated to be between 1.1 to 1.65. For neural stem cells (NSCs) and immune cells, there were no significant difference in the expression of Nestin and CD45 between proton and photon irradiation (both 20 and 30 Gy). Therefore, the RBE for NSCs and immune cell was determined to be 1.1. These findings highlight the varying RBE values of different cells in the hippocampus in vivo. Moreover, the actual RBE of the hippocampus may be higher than 1.1, suggesting that using as RBE value of 1.1 in clinical practice may underestimate the toxicities induced by proton radiation.


Subject(s)
Proton Therapy , Protons , Rats , Animals , Proton Therapy/methods , Nestin , Relative Biological Effectiveness , Rats, Sprague-Dawley , Hippocampus
12.
Phys Med Biol ; 69(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38537301

ABSTRACT

Thein vivoevolution of radiotherapy necessitates innovative platforms for preclinical investigation, bridging the gap between bench research and clinical applications. Understanding the nuances of radiation response, specifically tailored to proton and photon therapies, is critical for optimizing treatment outcomes. Within this context, preclinicalin vivoexperimental setups incorporating image guidance for both photon and proton therapies are pivotal, enabling the translation of findings from small animal models to clinical settings. TheSAPPHIREproject represents a milestone in this pursuit, presenting the installation of the small animal radiation therapy integrated beamline (SmART+ IB, Precision X-Ray Inc., Madison, Connecticut, USA) designed for preclinical image-guided proton and photon therapy experiments at University Proton Therapy Dresden. Through Monte Carlo simulations, low-dose on-site cone beam computed tomography imaging and quality assurance alignment protocols, the project ensures the safe and precise application of radiation, crucial for replicating clinical scenarios in small animal models. The creation of Hounsfield lookup tables and comprehensive proton and photon beam characterizations within this system enable accurate dose calculations, allowing for targeted and controlled comparison experiments. By integrating these capabilities,SAPPHIREbridges preclinical investigations and potential clinical applications, offering a platform for translational radiobiology research and cancer therapy advancements.


Subject(s)
Photons , Proton Therapy , Radiotherapy, Image-Guided , Photons/therapeutic use , Animals , Radiotherapy, Image-Guided/methods , Proton Therapy/methods , Monte Carlo Method , Protons , Mice
13.
Radiother Oncol ; 194: 110197, 2024 May.
Article in English | MEDLINE | ID: mdl-38447870

ABSTRACT

PURPOSE: A better characterization of the dependence of the tissue sparing effect at ultra-high dose rate (UHDR) on physical beam parameters (dose, dose rate, radiation quality) would be helpful towards a mechanistic understanding of the FLASH effect and for its broader clinical translation. To address this, a comprehensive study on the normal tissue sparing at UHDR using the zebrafish embryo (ZFE) model was conducted. METHODS: One-day-old ZFE were irradiated over a wide dose range (15-95 Gy) in three different beams (proton entrance channel, proton spread out Bragg peak and 30 MeV electrons) at UHDR and reference dose rate. After irradiation the ZFE were incubated for 4 days and then analyzed for four different biological endpoints (pericardial edema, curved spine, embryo length and eye diameter). RESULTS: Dose-effect curves were obtained and a sparing effect at UHDR was observed for all three beams. It was demonstrated that proton relative biological effectiveness and UHDR sparing are both relevant to predict the resulting dose response. Dose dependent FLASH modifying factors (FMF) for ZFE were found to be compatible with rodent data from the literature. It was found that the UHDR sparing effect saturates at doses above âˆ¼ 50 Gy with an FMF of âˆ¼ 0.7-0.8. A strong dose rate dependence of the tissue sparing effect in ZFE was observed. The magnitude of the maximum sparing effect was comparable for all studied biological endpoints. CONCLUSION: The ZFE model was shown to be a suitable pre-clinical high-throughput model for radiobiological studies on FLASH radiotherapy, providing results comparable to rodent models. This underlines the relevance of ZFE studies for FLASH radiotherapy research.


Subject(s)
Dose-Response Relationship, Radiation , Electrons , Embryo, Nonmammalian , Zebrafish , Animals , Zebrafish/embryology , Electrons/therapeutic use , Embryo, Nonmammalian/radiation effects , Proton Therapy/methods , Radiotherapy Dosage , Protons , Relative Biological Effectiveness
14.
Phys Med Biol ; 69(9)2024 Apr 17.
Article in English | MEDLINE | ID: mdl-38537311

ABSTRACT

Objective. Conventional transarterial chemoembolization (cTACE) is a common treatment for hepatocellular carcinoma (HCC), often with unsatisfactory local controls. Combining cTACE with radiotherapy shows a promise for unresectable large HCC, with proton therapy preserving healthy liver tissue. However, the proton therapy benefits are subject to the accuracy of tissue relative stopping power (RSP) prediction. The RSP values are typically derived from computed tomography (CT) images using stoichiometric calibration. Lipiodol deposition significantly increases CT numbers in liver regions of post-cTACE. Hence, it is necessary to evaluate the accuracy of RSP in liver regions of post-cTACE.Approach. Liver, water, and iodinated oil samples were prepared. Some liver samples contained iodinated oil. The water equivalent path length (WEPL) of sample was measured through the pullbacks of spread-out Bragg peak (SOBP) depth-dose profiles scanned in a water tank with and without sample in the beam path. Measured RSP values were compared to estimated RSP values derived from the CT number based on the stoichiometric calibration method.Main results. The measured RSP of water was 0.991, confirming measurement system calibration. After removing the RSP contribution from container walls, the pure iodinated oil and liver samples had RSP values of 1.12 and 1.06, while the liver samples mixed with varying oil volumes (5 ml, 10 ml, 15 ml) showed RSP values of 1.05, 1.05 and 1.06. Using the stoichiometric calibration method, pure iodinated oil and liver samples had RSP values of 2.79 and 1.06. Liver samples mixed with iodinated oil (5 ml, 10 ml, 15 ml) had calculated RSP values of 1.21, 1.34, and 1.46. The RSP discrepancy reached 149.1% for pure iodinated oil.Significance.Iodinated oil notably raises CT numbers in liver tissue. However, there is almost no effect on its RSP value. Proton treatment of post-cTACE HCC patients can therefore be overshooting if no proper measures are taken against this specific effect.


Subject(s)
Carcinoma, Hepatocellular , Chemoembolization, Therapeutic , Liver Neoplasms , Proton Therapy , Humans , Proton Therapy/methods , Carcinoma, Hepatocellular/diagnostic imaging , Carcinoma, Hepatocellular/radiotherapy , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/radiotherapy , Water
15.
Phys Med Biol ; 69(9)2024 Apr 15.
Article in English | MEDLINE | ID: mdl-38537287

ABSTRACT

Objective.Online magnetic resonance imaging (MRI) guidance could be especially beneficial for pencil beam scanned (PBS) proton therapy of tumours affected by respiratory motion. For the first time to our knowledge, we investigate the dosimetric impact of respiratory motion on MRI-guided proton therapy compared to the scenario without magnetic field.Approach.A previously developed analytical proton dose calculation algorithm accounting for perpendicular magnetic fields was extended to enable 4D dose calculations. For two geometrical phantoms and three liver and two lung patient cases, static treatment plans were optimised with and without magnetic field (0, 0.5 and 1.5 T). Furthermore, plans were optimised using gantry angle corrections (0.5 T +5° and 1.5 T +15°) to reproduce similar beam trajectories compared to the 0 T reference plans. The effect of motion was then considered using 4D dose calculations without any motion mitigation and simulating 8-times volumetric rescanning, with motion for the patient cases provided by 4DCT(MRI) data sets. Each 4D dose calculation was performed for different starting phases and the CTV dose coverageV95%and homogeneityD5%-D95%were analysed.Main results.For the geometrical phantoms with rigid motion perpendicular to the beam and parallel to the magnetic field, a comparable dosimetric effect was observed independent of the magnetic field. Also for the five 4DCT(MRI) cases, the influence of motion was comparable for all magnetic field strengths with and without gantry angle correction. On average, the motion-induced decrease in CTVV95%from the static plan was 17.0% and 18.9% for 1.5 T and 0.5 T, respectively, and 19.9% without magnetic field.Significance.For the first time, this study investigates the combined impact of magnetic fields and respiratory motion on MR-guided proton therapy. The comparable dosimetric effects irrespective of magnetic field strength indicate that the effects of motion for future MR-guided proton therapy may not be worse than for conventional PBS proton therapy.


Subject(s)
Lung Neoplasms , Proton Therapy , Humans , Proton Therapy/methods , Motion , Radiometry/methods , Protons , Magnetic Resonance Imaging/methods , Radiotherapy Planning, Computer-Assisted/methods , Four-Dimensional Computed Tomography/methods , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy
16.
Phys Med ; 120: 103323, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38461635

ABSTRACT

PURPOSE: We investigated interplay effects and treatment time (TT) in scanned proton therapy for lung cancer patients. We compared free-breathing (FB) approaches with multiple rescanning strategies and respiratory-gating (RG) methods with various gating widths to identify the superior irradiation technique. METHODS: Plans were created with 4/1, 2/2, and 1/4 layered/volume rescans of FB (L4V1, L2V2, and L1V4), and 50%, 30%, and 10% gating widths of the total respiratory curves (G50, G30, and G10) of the RG plans with L4V1. We calculated 4-dimensional dynamic doses assuming a constant sinusoidal curve for six irradiation methods. The reconstructed doses per fraction were compared with planned doses in terms of dose differences in 99% clinical-target-volume (CTV) (ΔD99%), near-maximum dose differences (ΔD2%) at organs-at-risk (OARs), and TT. RESULTS: The mean/minimum CTV ΔD99% values for FB were -1.0%/-4.9%, -0.8%/-4.3%, and -0.1%/-1.0% for L4V1, L2V2, and L1V4, respectively. Those for RG were -0.3%/-1.7%, -0.1%/-1.0%, and 0.0%/-0.5% for G50, G30, and G10, respectively. The CTV ΔD99% of the RGs with less than 50% gate width and the FBs of L1V4 were within the desired tolerance (±3.0%), and the OARs ΔD2% for RG were lower than those for FB. The mean TTs were 90, 326, 824, 158, 203, and 422 s for L4V1, L2V2, L1V4, G50, G30, and G10, respectively. CONCLUSIONS: FB (L4V1) is the most efficient treatment, but not necessarily the optimal choice due to interplay effects. To satisfy both TT extensions and interplay, RG with a gate width as large as possible within safety limits is desirable.


Subject(s)
Lung Neoplasms , Proton Therapy , Humans , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Respiration , Radiotherapy Dosage , Four-Dimensional Computed Tomography/methods
17.
Phys Med ; 120: 103329, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38492331

ABSTRACT

GOAL: In-beam Positron Emission Tomography (PET) is a technique for in-vivo non-invasive treatment monitoring for proton therapy. To detect anatomical changes in patients with PET, various analysis methods exist, but their clinical interpretation is problematic. The goal of this work is to investigate whether the gamma-index analysis, widely used for dose comparisons, is an appropriate tool for comparing in-beam PET distributions. Focusing on a head-and-neck patient, we investigate whether the gamma-index map and the passing rate are sensitive to progressive anatomical changes. METHODS/MATERIALS: We simulated a treatment course of a proton therapy patient using FLUKA Monte Carlo simulations. Gradual emptying of the sinonasal cavity was modeled through a series of artificially modified CT scans. The in-beam PET activity distributions from three fields were evaluated, simulating a planar dual head geometry. We applied the 3D-gamma evaluation method to compare the PET images with a reference image without changes. Various tolerance criteria and parameters were tested, and results were compared to the CT-scans. RESULTS: Based on 210 MC simulations we identified appropriate parameters for the gamma-index analysis. Tolerance values of 3 mm/3% and 2 mm/2% were suited for comparison of simulated in-beam PET distributions. The gamma passing rate decreased with increasing volume change for all fields. CONCLUSION: The gamma-index analysis was found to be a useful tool for comparing simulated in-beam PET images, sensitive to sinonasal cavity emptying. Monitoring the gamma passing rate behavior over the treatment course is useful to detect anatomical changes occurring during the treatment course.


Subject(s)
Proton Therapy , Humans , Proton Therapy/methods , Monte Carlo Method , Positron-Emission Tomography/methods , Tomography, X-Ray Computed/methods , Computer Simulation , Etoposide , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods
18.
Phys Med ; 120: 103325, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38493583

ABSTRACT

PURPOSE: The present study aimed to develop a porous structure with plug-ins (PSP) to broaden the Bragg peak width (BPW, defined as the distance in water between the proximal and distal 80% dose) of the carbon ion beam while maintaining a sharp distal falloff width (DFW, defined as the distance along the beam axis where the dose in water reduces from 80% to 20%). METHODS: The binary voxel models of porous structure (PS) and PSP were established in the Monte Carlo code FLUKA and the corresponding physical models were manufactured by 3D printing. Both experiment and simulation were performed for evaluating the modulation capacity of PS and PSP. BPWs and DFWs derived from each integral depth dose curves were compared. Fluence homogeneity of 430 MeV/u carbon-ion beam passing through the PSP was recorded by analyzing radiochromic films at six different locations downstream the PSP in the experiment. Additionally, by changing the beam spot size and incident position on the PSP, totally 48 different carbon-ion beams were simulated and corresponding deviations of beam metrics were evaluated to test the modulating stability of PSP. RESULTS: According to the measurement data, the use of PSP resulted in an average increase of 0.63 mm in BPW and a decrease of 0.74 mm in DFW compared to PS. The 2D radiation field inhomogeneities were lower than 3 % when the beam passing through a ≥ 10 cm PMMA medium. Furthermore, employing a spot size of ≥ 6 mm ensures that beam metric deviations, including BPW, DFW, and range, remain within a deviation of 0.1 mm across various incident positions. CONCLUSION: The developed PSP demonstrated its capability to effectively broaden the BPW of carbon ion beams while maintaining a sharp DFW comparing to PS. The superior performance of PSP, indicates its potential for clinical use in the future.


Subject(s)
Heavy Ion Radiotherapy , Proton Therapy , Monte Carlo Method , Porosity , Heavy Ion Radiotherapy/methods , Carbon , Water , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Proton Therapy/methods
19.
Phys Med ; 120: 103332, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38518627

ABSTRACT

As part of translational research projects, mice may be irradiated on radiobiology platforms such as the one at the ARRONAX cyclotron. Generally, these platforms do not feature an integrated imaging system. Moreover, in the context of ultra-high dose-rate radiotherapy (FLASH-RT), treatment planning should consider potential changes in the beam characteristics and internal movements in the animal. A patient-like set-up and methodology has been implemented to ensure target coverage during conformal irradiations of the brain, lungs and intestines. In addition, respiratory cycle amplitudes were quantified by fluoroscopic acquisitions on a mouse, to ensure organ coverage and to assess the impact of respiration during FLASH-RT using the 4D digital phantom MOBY. Furthermore, beam incidence direction was studied from mice µCBCT and Monte Carlo simulations. Finally,in vivodosimetry with dose-rate independent radiochromic films (OC-1) and their LET dependency were investigated. The immobilization system ensures that the animal is held in a safe and suitable position. The geometrical evaluation of organ coverage, after the addition of the margins around the organs, was satisfactory. Moreover, no measured differences were found between CONV and FLASH beams enabling a single model of the beamline for all planning studies. Finally, the LET-dependency of the OC-1 film was determined and experimentally verified with phantoms, as well as the feasibility of using these filmsin vivoto validate the targeting. The methodology developed ensures accurate and reproducible preclinical irradiations in CONV and FLASH-RT without in-room image guidance in terms of positioning, dose calculation andin vivodosimetry.


Subject(s)
Proton Therapy , Radiotherapy, Conformal , Humans , Mice , Animals , Protons , Proton Therapy/methods , Lung , Phantoms, Imaging , Monte Carlo Method , Carmustine , Etoposide , Radiotherapy Dosage
20.
Phys Med ; 120: 103341, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38554639

ABSTRACT

BACKGROUND AND PURPOSE: This work introduces the first assessment of CT calibration following the ESTRO's consensus guidelines and validating the HLUT through the irradiation of biological material. METHODS: Two electron density phantoms were scanned with two CT scanners using two CT scan energies. The stopping power ratio (SPR) and mass density (MD) HLUTs for different CT scan energies were derived using Schneider's and ESTRO's methods. The comparison metric in this work is based on the Water-Equivalent Thickness (WET) difference between the treatment planning system and biological irradiation measurement. The SPR HLUTs were compared between the two calibration methods. To assess the accuracy of using MD HLUT for dose calculation in the treatment planning system, MD vs SPR HLUT was compared. Lastly, the feasibility of using a single SPR HLUT to replace two different energy CT scans was explored. RESULTS: The results show a WET difference of less than 3.5% except for the result in the Bone region between Schneider's and ESTRO's methods. Comparing MD and SPR HLUT, the results from MD HLUT show less than a 3.5% difference except for the Bone region. However, the SPR HLUT shows a lower mean absolute percentage difference as compared to MD HLUT between the measured and calculated WET difference. Lastly, it is possible to use a single SPR HLUT for two different CT scan energies since both WET differences are within 3.5%. CONCLUSION: This is the first report on calibrating an HLUT following the ESTRO's guidelines. While our result shows incremental improvement in range uncertainty using the ESTRO's guideline, the prescriptional approach of the guideline does promote harmonization of CT calibration protocols between different centres.


Subject(s)
Proton Therapy , Protons , Proton Therapy/methods , Phantoms, Imaging , Tomography, X-Ray Computed/methods , Tomography Scanners, X-Ray Computed , Calibration , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...