Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 17.542
Filter
1.
Sci Rep ; 14(1): 10612, 2024 05 09.
Article in English | MEDLINE | ID: mdl-38719936

ABSTRACT

Molecular diagnostics involving nucleic acids (DNA and RNA) are regarded as extremely functional tools. During the 2020 global health crisis, efforts intensified to optimize the production and delivery of molecular diagnostic kits for detecting SARS-CoV-2. During this period, RT-LAMP emerged as a significant focus. However, the thermolability of the reagents used in this technique necessitates special low-temperature infrastructure for transport, storage, and conservation. These requirements limit distribution capacity and necessitate cost-increasing adaptations. Consequently, this report details the development of a lyophilization protocol for reagents in a colorimetric RT-LAMP diagnostic kit to detect SARS-CoV-2, facilitating room-temperature transport and storage. We conducted tests to identify the ideal excipients that maintain the molecular integrity of the reagents and ensure their stability during room-temperature storage and transport. The optimal condition identified involved adding 5% PEG 8000 and 75 mM trehalose to the RT-LAMP reaction, which enabled stability at room temperature for up to 28 days and yielded an analytical and diagnostic sensitivity and specificity of 83.33% and 90%, respectively, for detecting SARS-CoV-2. This study presents the results of a lyophilized colorimetric RT-LAMP COVID-19 detection assay with diagnostic sensitivity and specificity comparable to RT-qPCR, particularly in samples with high viral load.


Subject(s)
COVID-19 , Colorimetry , Freeze Drying , Molecular Diagnostic Techniques , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Colorimetry/methods , Nucleic Acid Amplification Techniques/methods , Molecular Diagnostic Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , Sensitivity and Specificity , Reagent Kits, Diagnostic/standards , COVID-19 Nucleic Acid Testing/methods
2.
Anal Chem ; 96(19): 7479-7486, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38689560

ABSTRACT

In the pathogenesis of microglia, brain immune cells promote nitrergic stress by overproducing nitric oxide (NO), leading to neuroinflammation. Furthermore, NO has been linked to COVID-19 progression, which has caused significant morbidity and mortality. SARS-CoV-2 infection activates inflammation by releasing excess NO and causing cell death in human microglial clone 3 (HMC3). In addition, NO regulates lysosomal functions and complex machinery to neutralize pathogens through phagocytosis. Therefore, developing lysosome-specific NO probes to monitor phagocytosis in microglia during the COVID-19 infection would be a significant study. Herein, a unique synthetic strategy was adopted to develop a NO selective fluorescent probe, PDM-NO, which can discriminate activated microglia from their resting state. The nonfluorescent PDM-NO exhibits a turn-on response toward NO only at lysosomal pH (4.5-5.5). Quantum chemical calculations (DFT/TD-DFT/PCM) and photophysical study revealed that the photoinduced electron transfer (PET) process is pivotal in tuning optical properties. PDM-NO demonstrated good biocompatibility and lysosomal specificity in activated HMC3 cells. Moreover, it can effectively map the dynamics of lysosomal NO against SARS-CoV-2 RNA-induced neuroinflammation in HMC3. Thus, PDM-NO is a potential fluorescent marker for detecting RNA virus infection and monitoring phagocytosis in HMC3.


Subject(s)
COVID-19 , Fluorescent Dyes , Lysosomes , Microglia , Nitric Oxide , Phagocytosis , SARS-CoV-2 , Microglia/virology , Microglia/metabolism , SARS-CoV-2/isolation & purification , Humans , Lysosomes/metabolism , Nitric Oxide/metabolism , Nitric Oxide/analysis , COVID-19/virology , COVID-19/diagnosis , COVID-19/metabolism , Fluorescent Dyes/chemistry , RNA, Viral/analysis , RNA, Viral/metabolism , Neuroinflammatory Diseases , Cell Line , Phenotype
3.
PLoS One ; 19(5): e0302000, 2024.
Article in English | MEDLINE | ID: mdl-38709720

ABSTRACT

Wastewater surveillance represents an alternative approach to regulating contamination and the early detection of infectious agents and outbreaks of diseases of public health importance. This study evaluated domestic wastewater effects on recreational waters in estuarine and seawater bodies in Guayas and Santa Elena provinces in Ecuador, South America. Fecal indicator bacteria (thermotolerant coliforms) served as key indicators for evaluation. Physical, chemical, and microbiological quality markers following the Ecuadorian environmental quality standard and the discharge of effluents to the water resource were analyzed. Samples were collected from 44 coastal sites and 2 oxidation lagoons during the dry and rainy seasons of 2020 and 2021, respectively. SARS-CoV-2 RNA was detected in samples with higher E. coli concentrations using reverse transcription quantitative PCR to detect the genes N and ORF1ab. All samples analyzed for SARS-CoV-2 showed Ct ˂ 40 for at least one gene. Four samples showed at least 20 genome copies of gene N per reaction. These were at an artisanal fishing port, an estuarine area (Palmar), a recreational bay, and an oxidation lagoon. A moderate correlation was found between SARS-CoV-2 RNA, thermotolerant coliform and E. coli (p-value ≤ 0.0037), and a strong and positive correlation between thermotolerant coliform and E. coli. (p-value ≤ 0.00001), highlighting the utility of these established parameters as a proxy of the virus. Significant differences were found in the concentrations of thermotolerant coliforms between seasons (p-value = 0.016) and sites (p-value = 0.005). The highest levels of coliforms were found in the dry season (63000 MPN/100 mL) in Anconcito and during the rainy season (14000 MPN/100 mL) at Esterillo in Playas County. It is recommended that the decentralized autonomous governments of the surveyed provinces in Ecuador implement urgent corrective actions and establish medium-term mechanisms to minimize a potential contamination route. Additional parameters must be included in the monitoring, such as Enterococcus and intestinal parasites, due to their public health implications. In the oxidation lagoons, maintenance actions must be carried out, including the dissolution of sediments, an increase in water retention times, and in situ treatment of the sludge, to improve the system's performance.


Subject(s)
COVID-19 , RNA, Viral , SARS-CoV-2 , Sewage , Water Quality , Ecuador , Sewage/virology , Sewage/microbiology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , RNA, Viral/genetics , RNA, Viral/isolation & purification , RNA, Viral/analysis , COVID-19/epidemiology , COVID-19/virology , Humans , Enterobacteriaceae/isolation & purification , Enterobacteriaceae/genetics , Water Microbiology , Environmental Monitoring/methods , Seawater/virology , Seawater/microbiology , Escherichia coli/genetics , Escherichia coli/isolation & purification , Wastewater/virology , Wastewater/microbiology
4.
Methods Mol Biol ; 2804: 195-206, 2024.
Article in English | MEDLINE | ID: mdl-38753149

ABSTRACT

Clinical diagnostics of infectious diseases via nucleic acid amplification tests (NAATs) depend on a separate step of isolation of nucleic acids from cells/viruses embedded in complex biological matrices. The most recent example has been reverse transcription polymerase chain reaction (RT-PCR) for amplification and detection of SARS-CoV-2 RNA for COVID-19 diagnostics. Kits for RNA extraction and purification are commercially available; however, their integration with amplification systems is generally lacking, resulting in two separate steps, i.e., sample preparation and amplification. This makes NAATs more time-consuming, requiring skilled personnel, and can increase the likelihood of contamination. Here, we describe a setup and methodology to perform the quick extraction and detection of nucleic acids in an integrated manner. In particular, we focus on the use of an immiscible filtration device for capture, isolation, concentration, amplification, and colorimetric detection of SARS-CoV-2 RNA.


Subject(s)
COVID-19 , Filtration , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , RNA, Viral/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Humans , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nucleic Acid Amplification Techniques/methods , Nucleic Acid Amplification Techniques/instrumentation , COVID-19/diagnosis , COVID-19/virology , Filtration/instrumentation , Filtration/methods , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/instrumentation , Colorimetry/methods , Colorimetry/instrumentation
5.
Anal Chim Acta ; 1309: 342693, 2024 Jun 22.
Article in English | MEDLINE | ID: mdl-38772660

ABSTRACT

BACKGROUND: CRISPR-Cas12a based one-step assays are widely used for nucleic acid detection, particularly for pathogen detection. However, the detection capability of the one-step assay is reduced because the Cas12a protein competes with the isothermal amplification enzymes for the target DNA and cleaves it. Therefore, the key to improving the sensitivity of the one-step assay is to address the imbalance between isothermal amplification and CRISPR detection. In previous study, we developed a Cas12a one-step assay using single-stranded DNA (ssDNA)-modified crRNA (mD-crRNA) and applied this method for the detection of pathogenic DNA. RESULTS: Here, we utilized mD-crRNA to establish a sensitive one-step assay that enables the visual detection of SARS-CoV-2 under ultraviolet light, achieving a detection limit of 5 aM without cross-reactivity. The sensitivity of mD-crRNA in the one-step assay was 100-fold higher than that of wild-type crRNA. Mechanistic studies revealed that the addition of ssDNA at the 3' end of mD-crRNA attenuates the binding affinity between the Cas12a-mD-crRNA complex and the target DNA. Consequently, this reduction in binding affinity decreases the cis-cleavage activity of Cas12a, mitigating its cleavage of the target DNA in the one-step assay. As a result, there is an augmentation in the amplification and accumulation of target DNA, thereby enhancing detection sensitivity. In the clinical testing of 40 SARS-CoV-2 RNA samples, the concordance between the results of the one-step assay and known qPCR results was 97.5 %. SIGNIFICANCE: The one-step assay using mD-crRNA proves to be highly sensitive and specificity and visually effective for the detection of SARS-CoV-2. Our study delves into the application of the mD-crRNA-mediated one-step assay in nucleic acid detection and its associated reaction mechanism. This holds great significance in addressing the inherent incompatibility issues between isothermal amplification and CRISPR detection.


Subject(s)
COVID-19 , DNA, Single-Stranded , Nucleic Acid Amplification Techniques , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , DNA, Single-Stranded/chemistry , DNA, Single-Stranded/genetics , Nucleic Acid Amplification Techniques/methods , Humans , RNA, Viral/analysis , RNA, Viral/genetics , COVID-19/diagnosis , COVID-19/virology , Limit of Detection , CRISPR-Cas Systems/genetics , Endodeoxyribonucleases/chemistry , Endodeoxyribonucleases/metabolism , Endodeoxyribonucleases/genetics , CRISPR-Associated Proteins/metabolism , CRISPR-Associated Proteins/genetics , Bacterial Proteins
6.
Mikrochim Acta ; 191(6): 333, 2024 05 16.
Article in English | MEDLINE | ID: mdl-38753167

ABSTRACT

The COVID-19 pandemic has underscored the urgent need for rapid and reliable strategies for early detection of SARS-CoV-2. In this study, we propose a DNA nanosphere-based crosslinking catalytic hairpin assembly (CCHA) system for the rapid and sensitive SARS-CoV-2 RNA detection. The CCHA system employs two DNA nanospheres functionalized with catalytic hairpin assembly (CHA) hairpins. The presence of target SARS-CoV-2 RNA initiated the crosslinking of DNA nanospheres via CHA process, leading to the amplification of fluorescence signals. As a result, the speed of SARS-CoV-2 diagnosis was enhanced by significantly increasing the local concentration of the reagents in a crosslinked DNA product, leading to a detection limit of 363 fM within 5 min. The robustness of this system has been validated in complex environments, such as fetal bovine serum and saliva. Hence, the proposed CCHA system offers an efficient and simple approach for rapid detection of SARS-CoV-2 RNA, holding substantial promise for enhancing COVID-19 diagnosis.


Subject(s)
COVID-19 , Limit of Detection , RNA, Viral , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Humans , COVID-19/diagnosis , COVID-19/virology , Nanospheres/chemistry , DNA/chemistry , Inverted Repeat Sequences , Animals , COVID-19 Nucleic Acid Testing/methods , Cattle , Cross-Linking Reagents/chemistry , Saliva/virology
7.
Clin Lab ; 70(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38747914

ABSTRACT

BACKGROUND: Nucleic acid amplification testing is the gold standard for SARS-CoV-2 diagnostics, although it may produce a certain number of false positive results. There has not been much published about the characteristics of false positive results. In this study, based on retesting, specimens that initially tested positive for SARS-CoV-2 were classified as true or false positive groups to characterize the distribution of cycle threshold (CT) values for N1 and N2 targets and number of targets detected for each group. METHODS: Specimens that were positive for N-gene on retesting and accompanied with S-gene were identified as true positives (true positive based on retesting, rTP), while specimens that retested negative were classified as false positives (false positive based on retesting, rFP). RESULTS: Of the specimens retested, 85/127 (66.9%) were rFP, 16/47 (34.0%) specimens with both N1 and N2 targets initially detected were rFP, and the CT values for each target was higher in rFP than in rTP. ROC curve analysis showed that optimal cutoff values of CT to differentiate between rTP and rFP were 34.8 for N1 and 33.0 for N2. With the optimal cutoff values of CT for each target, out of the 24 specimens that were positive for both N1 and N2 targets and classified as rTP, 23 (95.8%) were correctly identified as true positives. rFP specimens had a single N1 target in 52/61 (85.2%) and a single N2 target in 17/19 (89.5%). Notably, no true positive results were obtained from any specimens with only N2 target detected. CONCLUSIONS: These results suggest that retesting should be performed for positive results with a CT value greater than optimal cutoff value for each target or with a single N1 target amplified, considering the possibility of a false positive. This may provide guidance on indications to perform retesting to minimize the number of false positives.


Subject(s)
COVID-19 Nucleic Acid Testing , COVID-19 , SARS-CoV-2 , Humans , False Positive Reactions , SARS-CoV-2/genetics , COVID-19/diagnosis , COVID-19/virology , COVID-19 Nucleic Acid Testing/methods , COVID-19 Nucleic Acid Testing/standards , ROC Curve , Spike Glycoprotein, Coronavirus/genetics , Sensitivity and Specificity , Coronavirus Nucleocapsid Proteins/genetics , RNA, Viral/genetics , RNA, Viral/analysis
8.
Anal Chem ; 96(15): 5752-5756, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38560822

ABSTRACT

Viruses are the primary cause of many infectious diseases in both humans and animals. Various testing methods require an amplification step of the viral RNA sample before detection, with quantitative reverse transcription polymerase chain reaction (RT-qPCR) being one of the most widely used along with lesser-known methods like Nucleic Acid Sequence-Based Amplification (NASBA). NASBA offers several advantages, such as isothermal amplification and high selectivity for specific sequences, making it an attractive option for low-income facilities. In this research, we employed a single electrochemical biosensor (E-Biosensor) designed for potentially detecting any virus by modifying the NASBA protocol. In this modified protocol, a reverse primer is designed with an additional 22-nucleotide sequence (tag region) at the 5'-end, which is added to the NASBA process. This tag region becomes part of the final amplicon generated by NASBA. It can hybridize with a single specific E-Biosensor probe set, enabling subsequent virus detection. Using this approach, we successfully detected three different viruses with a single E-Biosensor design, demonstrating the platform's potential for virus detection.


Subject(s)
Biosensing Techniques , Viruses , Animals , Humans , Sensitivity and Specificity , Self-Sustained Sequence Replication/methods , RNA, Viral/genetics , RNA, Viral/analysis , Viruses/genetics , Nucleic Acid Amplification Techniques
9.
Sci Rep ; 14(1): 8700, 2024 04 15.
Article in English | MEDLINE | ID: mdl-38622191

ABSTRACT

HIV infection has been a global public health threat and overall reported ~ 40 million deaths. Acquired immunodeficiency syndrome (AIDS) is attributed to the retroviruses (HIV-1/2), disseminated through various body fluids. The temporal progression of AIDS is in context to the rate of HIV-1 infection, which is twice as protracted in HIV-2 transmission. Q-PCR is the only available method that requires a well-developed lab infrastructure and trained personnel. Micro-PCR, a portable Q-PCR device, was developed by Bigtec Labs, Bangalore, India. It is simple, accurate, fast, and operationalised in remote places where diagnostic services are inaccessible in developing countries. This novel micro-PCR determines HIV-1 and HIV-2 viral load using a TruePrep™ extractor device for RNA isolation. Five ml blood samples were collected at the blood collection centre at AIIMS, New Delhi, India. Samples were screened for serology, and a comparison of HIV-1/2 RNA was done between qPCR and micro-PCR in the samples. The micro-PCR assay of HIV-RNA has compared well with those from real-time PCR (r = 0.99, i < 0.002). Micro-PCR has good inter and intra-assay reproducibility over a wide dynamic range (1.0 × 102-1.0 × 108 IU/ml). The linear dynamic range was 102-108 IU/ml. The clinical and analytical specificity of the assay was comparable, i.e., 100%. Intra-assay and inter-assay coefficients of variation ranged from 1.17% to 3.15% and from 0.02% to 0.46%, respectively. Moreover, due to the robust, simple, and empirical method, the Probit analysis has also been done for qPCR LODs to avoid uncertainties in target recoveries. The micro-PCR is reliable, accurate, and reproducible for early detection of HIV-1 and HIV-2 viral loads simultaneously. Thus, it can easily be used in the field and in remote places where quantification of both HIV-1/2 is not reachable.


Subject(s)
Acquired Immunodeficiency Syndrome , HIV Infections , HIV Seropositivity , HIV-1 , Humans , HIV-1/genetics , Reproducibility of Results , Sensitivity and Specificity , RNA, Viral/analysis , India , Real-Time Polymerase Chain Reaction/methods , HIV-2/genetics , Viral Load/methods
10.
JAMA ; 331(16): 1418-1419, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38557893
11.
Analyst ; 149(9): 2507-2525, 2024 Apr 29.
Article in English | MEDLINE | ID: mdl-38630498

ABSTRACT

Outbreaks of viral diseases seriously jeopardize people's health and cause huge economic losses. At the same time, virology provides a new perspective for biology, molecular biology and cancer research, and it is important to study the discovered viruses with potential applications. Therefore, the development of immediate and rapid viral detection methods for the prevention and treatment of viral diseases as well as the study of viruses has attracted extensive attention from scientists. With the continuous progress of science and technology, especially in the field of bioanalysis, a series of new detection techniques have been applied to the on-site rapid detection of viruses, which has become a powerful approach for human beings to fight against viruses. In this paper, the latest research progress of rapid point-of-care detection of viral nucleic acids, antigens and antibodies is presented. In addition, the advantages and disadvantages of these technologies are discussed from the perspective of practical application requirements. Finally, the problems and challenges faced by rapid viral detection methods and their development prospects are discussed.


Subject(s)
Point-of-Care Testing , Viruses , Humans , Viruses/isolation & purification , Viruses/genetics , Virus Diseases/diagnosis , Antigens, Viral/analysis , Antibodies, Viral/immunology , Antibodies, Viral/analysis , Biosensing Techniques/methods , Point-of-Care Systems , RNA, Viral/analysis , RNA, Viral/genetics
12.
Biosensors (Basel) ; 14(4)2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38667150

ABSTRACT

Since its first appearance in 1981, HIV-1 has remained a global concern. Current methods for diagnosing HIV-1, while effective, are mostly specific to a given subtype of HIV-1 and often require expensive equipment and highly trained individuals to collect and process the sample. It is necessary to develop a sensitive diagnostic method that can be administered with minimal equipment to provide better care in low-resource settings. Loop-mediated isothermal amplification is a rapid and sensitive method for detecting the presence of specific nucleic acid sequences. Herein we report the development and comparison of two different HIV LAMP assays, integrase and VPR, as well as the comparison between TRIZol and magnetic beads RNA extraction methods for each assay. Our analysis shows that the integrase assay was able to detect the virus from multiple subtypes in under 30 min with a variable limit of detection (LOD) that was dependent on the HIV-1 subtype.


Subject(s)
HIV Infections , HIV-1 , Nucleic Acid Amplification Techniques , HIV-1/isolation & purification , HIV-1/genetics , Nucleic Acid Amplification Techniques/methods , Humans , HIV Infections/diagnosis , HIV Infections/virology , Molecular Diagnostic Techniques/methods , Limit of Detection , RNA, Viral/analysis
13.
J Appl Microbiol ; 135(4)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38637309

ABSTRACT

AIMS: To monitor severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) RNA contamination in vehicles operating in England during the pandemic, to better understand transmission risk of SARS-CoV-2 on public transport. METHODS AND RESULTS: We collected 1314 surface samples between December 2020 and April 2022 on trains and buses managed by five different transport operators. The presence of SARS-CoV-2 RNA was investigated through reverse transcription polymerase chain reaction (RT-PCR). SARS-CoV-2 RNA was found on 197 (15%) of the 1314 surfaces sampled, including seat head rests, handholds, and air extract grilles, but the levels of RNA recovered on those samples (median value of 23.4, interquartile range: 14.3-35.4, N gene copies per extraction) made the presence of infectious virus at the time of sampling extremely unlikely. However, detection rates varied over time with peaks broadly coinciding with times of high community transmission, when it was more likely that people infected with SARS-CoV-2 were travelling on public transport. CONCLUSION: During the pandemic, and as in other public spaces, low levels of SARS-CoV-2 RNA were found on surfaces associated with public transport.


Subject(s)
COVID-19 , RNA, Viral , SARS-CoV-2 , COVID-19/transmission , COVID-19/virology , COVID-19/epidemiology , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , England/epidemiology , RNA, Viral/genetics , RNA, Viral/analysis , RNA, Viral/isolation & purification , Humans , Longitudinal Studies , Motor Vehicles , Transportation
14.
Lab Chip ; 24(9): 2485-2496, 2024 Apr 30.
Article in English | MEDLINE | ID: mdl-38587207

ABSTRACT

The COVID-19 pandemic greatly impacted the in vitro diagnostic market, leading to the development of new technologies such as point-of-care testing (POCT), multiplex testing, and digital health platforms. In this study, we present a self-contained microfluidic chip integrated with an internet-of-things (IoT)-based point-of-care (POC) device for rapid and sensitive diagnosis of respiratory viruses. Our platform enables sample-to-answer diagnostics within 70 min by automating RNA extraction, reverse transcription-loop-mediated isothermal amplification (RT-LAMP), and fluorescence detection. The microfluidic chip is designed to store all the necessary reagents for the entire diagnostic assay, including a lysis buffer, a washing buffer, an elution buffer, and a lyophilized RT-LAMP cocktail. It can perform nucleic acid extraction, aliquoting, and gene amplification in multiple reaction chambers without cross-contamination. The IoT-based POC device consists of a Raspberry Pi 4 for device control and data processing, a CMOS sensor for measuring fluorescence signals, a resistive heater panel for temperature control, and solenoid valves for controlling the movement of on-chip reagent solutions. The proposed device is portable and features a touchscreen for user control and result display. We evaluated the performance of the platform using 11 clinical respiratory virus samples, including 5 SARS-CoV-2 samples, 2 influenza A samples, and 4 influenza B samples. All tested clinical samples were accurately identified with high specificity and fidelity, demonstrating the ability to simultaneously detect multiple respiratory viruses. The combination of the integrated microfluidic chip with the POC device offers a simple, cost-effective, and scalable solution for rapid molecular diagnosis of respiratory viruses in resource-limited settings.


Subject(s)
COVID-19 , Internet of Things , Lab-On-A-Chip Devices , Nucleic Acid Amplification Techniques , SARS-CoV-2 , Humans , COVID-19/diagnosis , COVID-19/virology , SARS-CoV-2/isolation & purification , SARS-CoV-2/genetics , Nucleic Acid Amplification Techniques/instrumentation , Point-of-Care Systems , Molecular Diagnostic Techniques/instrumentation , Equipment Design , Point-of-Care Testing , RNA, Viral/analysis , RNA, Viral/isolation & purification , RNA, Viral/genetics , Respiratory Tract Infections/diagnosis , Respiratory Tract Infections/virology
15.
Talanta ; 274: 126009, 2024 Jul 01.
Article in English | MEDLINE | ID: mdl-38579420

ABSTRACT

Nucleic acid detection is conducive to preventing the spread of COVID-19 pandemic. In this work, we successfully designed a soft interface confined DNA walker by anchoring hairpin reporter probes on cell membranes for the detection of SARS-CoV-2 variants. In the presence of target RNA, the cyclic self-assembly reaction occurred between hairpin probes H1 and H2, and the continuous walking of target RNA on cell membranes led to the gradual amplification of fluorescence signal. The enrichment of H1 on membranes and the unique fluidity of membranes promoted the collision efficiency between DNA strands in the reaction process, endowing this method with high sensitivity. In addition, the double-blind test of synthetic RNA in 5% normal human serum demonstrated the good stability and anti-interference in complex environment of this method, which exhibited great potential in clinical diagnostics.


Subject(s)
COVID-19 , SARS-CoV-2 , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , Humans , COVID-19/diagnosis , COVID-19/virology , RNA, Viral/genetics , RNA, Viral/analysis , DNA/chemistry , DNA/analysis , Limit of Detection , COVID-19 Nucleic Acid Testing/methods
16.
Anal Bioanal Chem ; 416(13): 3161-3171, 2024 May.
Article in English | MEDLINE | ID: mdl-38558309

ABSTRACT

Since RNA is an important biomarker of many infectious pathogens, RNA detection of pathogenic organisms is crucial for disease diagnosis and environmental and food safety. By simulating the base mismatch during DNA replication, this study presents a novel three-way junction structure-mediated reverse transcription-free exponential amplification reaction (3WJ-RTF-EXPAR) for the rapid and sensitive detection of pathogen RNA. The target RNA served as a switch to initiate the reaction by forming a three-way junction (3WJ) structure with the ex-trigger strand and the ex-primer strand. The generated trigger strand could be significantly amplified through EXPAR to open the stem-loop structure of the molecular beacon to emit fluorescence signal. The proofreading activity of Vent DNA polymerase, in combination with the unique structure of 2+1 bases at the 3'-end of the ex-primer strand, could enhance the role of target RNA as a reaction switch to reduce non-specific amplification and ensure excellent specificity to differentiate target pathogen from those causing similar symptoms. Furthermore, detection of target RNA showed a detection limit of 1.0×104 copies/mL, while the time consumption was only 20 min, outperforming qRT-LAMP and qRT-PCR, the most commonly used RNA detection methods in clinical practice. All those indicates the great application prospects of this method in clinical diagnostic.


Subject(s)
Limit of Detection , Nucleic Acid Amplification Techniques , Nucleic Acid Amplification Techniques/methods , RNA, Viral/analysis , RNA, Viral/genetics , RNA, Bacterial/analysis , RNA, Bacterial/genetics , Humans
17.
Anal Bioanal Chem ; 416(13): 3195-3203, 2024 May.
Article in English | MEDLINE | ID: mdl-38613682

ABSTRACT

We propose a sensitive H1N1 virus fluorescence biosensor based on ligation-transcription and CRISPR/Cas13a-assisted cascade amplification strategies. Products are generated via the hybridization of single-stranded DNA (ssDNA) probes containing T7 promoter and crRNA templates to a target RNA sequence using SplintR ligase. This generates large crRNA quantities in the presence of T7 RNA polymerase. At such crRNA quantities, ternary Cas13a, crRNA, and activator complexes are successfully constructed and activate Cas13a to enhance fluorescence signal outputs. The biosensor sensitively and specifically monitored H1N1 viral RNA levels down to 3.23 pM and showed good linearity when H1N1 RNA concentrations were 100 pM-1 µM. Biosensor specificity was also excellent. Importantly, our biosensor may be used to detect other viral RNAs by altering the sequences of the two probe junctions, with potential applications for the clinical diagnosis of viruses and other biomedical studies.


Subject(s)
Biosensing Techniques , CRISPR-Cas Systems , Influenza A Virus, H1N1 Subtype , RNA, Viral , Biosensing Techniques/methods , Influenza A Virus, H1N1 Subtype/genetics , Influenza A Virus, H1N1 Subtype/isolation & purification , RNA, Viral/analysis , RNA, Viral/genetics , Nucleic Acid Amplification Techniques/methods , Humans , Limit of Detection , Fluorescence , Transcription, Genetic
18.
Spectrochim Acta A Mol Biomol Spectrosc ; 315: 124184, 2024 Jul 05.
Article in English | MEDLINE | ID: mdl-38608556

ABSTRACT

This research proposes a highly sensitive and simple surface-enhanced Raman spectroscopy (SERS) assay for the detection of SARS-CoV-2 RNA using suitably designed probes specific for RdRp and N viral genes attached to a Raman marker. The sensitivity of the assay was optimized through precise adjustments to the conditions of immobilization and hybridization processes of the target RNA, including modifications to factors such as time and temperature. The assay achieved a remarkable sensitivity down to 58.39 copies/mL, comparable to or lower than the sensitivities reported for commercial fluorescent polymerase chain reaction (PCR) based methods. It has good selectivity in discriminating SARS-CoV-2 RNA against other respiratory viruses, respiratory syncytial virus (RSV), and influenza A virus. The reliability of the assay was validated by testing 24 clinical samples, including 12 positive samples with varying cycle threshold (Ct) values and 12 negative samples previously tested using real-time PCR. The assay consistently predicted true results that were in line with the PCR results for all samples. Furthermore, the assay demonstrated a notable limit of detection (LOD) of Ct (38 for RdRp gene and 37.5 for N-gene), indicating its capability to detect low concentrations of the target analyte and potentially facilitating early detection of the pathogen.


Subject(s)
COVID-19 , RNA, Viral , SARS-CoV-2 , Spectrum Analysis, Raman , Spectrum Analysis, Raman/methods , SARS-CoV-2/genetics , SARS-CoV-2/isolation & purification , RNA, Viral/genetics , RNA, Viral/analysis , Humans , COVID-19/diagnosis , COVID-19/virology , Limit of Detection , Reproducibility of Results , Sensitivity and Specificity
19.
Arch Iran Med ; 27(4): 191-199, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38685845

ABSTRACT

BACKGROUND: Gastric cancer is the fourth leading cause of cancer-related deaths in the world. The identification of gastric cancer subtypes related to recognizable microbial agents may play a pivotal role in the targeted prevention and treatment of this cancer. The current study is conducted to define the frequency of Epstein-Barr virus (EBV) infection in gastric cancers of four major provinces, with different incidence rates of gastric cancers, in Iran. METHODS: Paraffin blocks of 682 cases of various types of gastric cancer from Tehran, South and North areas of Iran were collected. Twelve tissue microarray (TMA) blocks were constructed from these blocks. Localization of EBV in tumors was assessed by in situ hybridization (ISH) for EBV-encoded RNA (EBER). Chi-squared test was used to evaluate the statistical significance between EBV-associated gastric cancer (EBVaGC) and clinicopathologic tumor characteristics. RESULTS: Fourteen out of 682 cases (2.1%) of gastric adenocarcinoma were EBER-positive. EBER was positive in 8 out of 22 (36.4%) of medullary carcinomas and 6 out of 660 (0.9%) of non-medullary type, which was a statistically significant difference (P<0.001). The EBVaGCs were more frequent in younger age (P=0.009) and also showed a trend toward the lower stage of the tumor (P=0.075). CONCLUSION: EBV-associated gastric adenocarcinoma has a low prevalence in Iran. This finding can be due to epidemiologic differences in risk factors and exposures, and the low number of gastric medullary carcinomas in the population. It may also be related to gastric tumor heterogeneity not detected with the TMA technique.


Subject(s)
Adenocarcinoma , Epstein-Barr Virus Infections , Herpesvirus 4, Human , In Situ Hybridization , Stomach Neoplasms , Tissue Array Analysis , Humans , Stomach Neoplasms/virology , Stomach Neoplasms/epidemiology , Iran/epidemiology , Male , Female , Middle Aged , Epstein-Barr Virus Infections/epidemiology , Epstein-Barr Virus Infections/complications , Herpesvirus 4, Human/genetics , Herpesvirus 4, Human/isolation & purification , Aged , Adenocarcinoma/virology , Adenocarcinoma/epidemiology , Adult , RNA, Viral/analysis , Aged, 80 and over
20.
PLoS One ; 19(3): e0300608, 2024.
Article in English | MEDLINE | ID: mdl-38489313

ABSTRACT

BACKGROUND: Hepatitis E virus (HEV) is a major cause of enterotropic viral hepatitis, a major public health problem in many developing countries. In Central African Republic (CAR), HEV genotypes 1, 2, and 3 have been found to have an impact on human health. However, data on HEV in animal reservoirs are still lacking for CAR. Here, we investigated the presence of HEV in farmed pigs and goats in Bangui, the capital city of CAR, using molecular methods. METHODOLOGY: In a prospective study, fecal samples from 61 pigs and 39 goats from farms in five districts (2nd, 4th, 6th, 7th, 8th) of Bangui were collected and tested for HEV RNA by real-time RT-PCR. The samples were further analyzed by nested-PCR and sequenced to determine the genotype and subtype to which the virus belong. RESULTS: In total, 22/100 (22.0%) feces samples were successfully amplified for HEV RNA by real time RT-PCR. All positive samples were from pigs (22/61; 36.1%), while all goat samples were negative (0/39). Twelve HEV RNA samples (12/22 or 54.5%) were successfully amplified by nested RT-PCR, and subsequently sequenced. Phylogenetic analysis revealed that the obtained sequences clustered with subtype 3h and were genetically related to the human HEV sequences from CAR. CONCLUSION: This study confirms that pigs constitute an HEV reservoir, with genotype 3 being the major circulating strain. Further studies are needed to investigate other local reservoirs and to improve knowledge of the molecular epidemiology of HEV in CAR.


Subject(s)
Hepatitis E virus , Hepatitis E , Swine Diseases , Swine , Animals , Humans , Hepatitis E virus/genetics , Hepatitis E/epidemiology , Hepatitis E/veterinary , Phylogeny , Central African Republic/epidemiology , Prospective Studies , Real-Time Polymerase Chain Reaction , RNA, Viral/genetics , RNA, Viral/analysis , Genotype , Feces/chemistry , Goats/genetics
SELECTION OF CITATIONS
SEARCH DETAIL
...