1.
Radiol. bras ; Radiol. bras;40(4): 263-266, jul.-ago. 2007. graf, tab
Article in Portuguese | LILACS | ID: lil-462380

ABSTRACT

OBJETIVO: O objetivo deste estudo foi avaliar a exposição ocupacional de auxiliares de enfermagem encarregados da assistência aos pacientes internados para terapia com 131I, num período de 11 anos. MATERIAIS E MÉTODOS: As situações de exposição foram classificadas de acordo com as respostas de três atendentes a um questionário que relaciona os procedimentos realizados às atividades administradas, às distâncias e aos tempos de permanência na enfermaria. Os registros das doses recebidas em dois tipos de dosímetros, em dois períodos subseqüentes, foram analisados. Em ambos os períodos os atendentes receberam instruções de proteção radiológica. RESULTADOS: Nas situações comuns o tempo de permanência na enfermaria está dentro do tempo de referência utilizado. Nas situações não-comuns, quando o paciente necessita de auxílio na locomoção, o tempo de exposição está acima do tempo de referência, no entanto, essa exposição ocorre somente uma ou duas vezes por ano. No período de 1993 a 1999 (filme dosimétrico) houve dez registros de doses, sendo todas ao nível de registro. No período de 2000 a 2003 (dosímetro termoluminescente) houve dez registros de doses, sendo uma delas situada no nível de investigação. Nesse período a atividade média utilizada duplicou. CONCLUSÃO: Não foi observado aumento significante nas doses dos atendentes.


OBJECTIVE: The present study was aimed at evaluating the occupational exposure of nursing staff in charge of inpatients undergoing 131I therapy during 11 years. MATERIALS AND METHODS: The exposure situations were classified according to a questionnaire answered by three nursing attendants, correlating the procedures with activities, distances and amount of time in the iodotherapy room. Records of received doses by two types of dosimeters were evaluated over two subsequent periods. In both periods the nursing attendants received instructions about radiological protection. RESULTS: In usual situations, their amount of time in the iodotherapy room was in compliance with the standard time established by the service. In unusual situations, where the patient needed assistance for mobility, the exposure period was above the standard. However, this exposure occurs casually (only one or two times a year). During the period between 1993 and 1999 (dosimetric films) there were ten dose records, all of them at record level. From 2000 to 2003 (thermoluminescent dosimeters) ten dose records were also obtained, with only one of them at the investigation level. During this study period, the mean 131I activity was doubled. CONCLUSION: Despite the increased levels of activity there was no significant increase in dose to nursing attendants.


Subject(s)
Humans , Radiation Dosimeters , Nursing Assistants , Occupational Exposure , Radiation Dosimeters/adverse effects , Occupational Exposure/analysis , Environmental Monitoring
SELECTION OF CITATIONS
SEARCH DETAIL