Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 4.762
Filter
1.
J Coll Physicians Surg Pak ; 34(5): 573-577, 2024 May.
Article in English | MEDLINE | ID: mdl-38720219

ABSTRACT

OBJECTIVE:  To compare the acute toxicities of two radiation treatment techniques, intensity modulated radiation therapy (IMRT), and 3-dimensional conformal radiation therapy (3D-CRT) in localised prostate adenocarcinoma. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oncology, Dr. Ziauddin Hospital, Karachi, Pakistan, from July 2016 to June 2022. METHODOLOGY: Patients with localised prostate adenocarcinoma who underwent treatment using two different advanced radiotherapy techniques i.e., IMRT and 3D-CRT were recruited during the study period. They were followed up for six months for acute gastrointestinal (GI) and genitourinary (GU) adverse events (acute toxicities) related to both treatment modalities according to Modified radiation therapy oncology group (RTOG) criteria. The acute toxicities were assessed at the 2nd, 4th, and 6th week during treatment and at the 3rd and 6th month after treatment. RESULTS:  There were 78 patients, with 39 patients in each group. The mean age was 68 ± 10 years in the 3D-CRT and 68 ± 07 years in the IMRT group. Patients in the IMRT group exhibited markedly lower treatment-related acute GI and GU effects at the end of 4th and 6th weeks for anorectal pain (p = 0.04) and (p = 0.01) and burning micturition (p = 0.003) and (p = 0.01), respectively. Furthermore, at 3 months anorectal pain (p = 0.02), loose stools (p = 0.005), and burning micturition (p = 0.01) were present and at 6 months anorectal pain was (p = 0.01) still present. CONCLUSION: Radiation therapy modalities 3D-CRT and IMRT both showed acceptable toxicity profile in the management of localised prostate cancer, while IMRT group exhibited significantly lower treatment-related acute GI and GU effects. KEY WORDS: 3D-CRT (3-Dimensional Conformal Radiation Therapy), IMRT (Intensity-Modulated Radiation Therapy), Radiation toxicity.


Subject(s)
Prostatic Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Male , Prostatic Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Aged , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Middle Aged , Radiation Injuries/etiology , Adenocarcinoma/radiotherapy , Adenocarcinoma/pathology , Pakistan , Radiotherapy Dosage
2.
Radiat Oncol ; 19(1): 49, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38627747

ABSTRACT

OBJECTIVE: This study evaluates various craniospinal irradiation (CSI) techniques used in Turkish centers to understand their advantages, disadvantages and overall effectiveness, with a focus on enhancing dose distribution. METHODS: Anonymized CT scans of adult and pediatric patients, alongside target volumes and organ-at-risk (OAR) structures, were shared with 25 local radiotherapy centers. They were tasked to develop optimal treatment plans delivering 36 Gy in 20 fractions with 95% PTV coverage, while minimizing OAR exposure. The same CT data was sent to a US proton therapy center for comparison. Various planning systems and treatment techniques (3D conformal RT, IMRT, VMAT, tomotherapy) were utilized. Elekta Proknow software was used to analyze parameters, assess dose distributions, mean doses, conformity index (CI), and homogeneity index (HI) for both target volumes and OARs. Comparisons were made against proton therapy. RESULTS: All techniques consistently achieved excellent PTV coverage (V95 > 98%) for both adult and pediatric patients. Tomotherapy closely approached ideal Dmean doses for all PTVs, while 3D-CRT had higher Dmean for PTV_brain. Tomotherapy excelled in CI and HI for PTVs. IMRT resulted in lower pediatric heart, kidney, parotid, and eye doses, while 3D-CRT achieved the lowest adult lung doses. Tomotherapy approached proton therapy doses for adult kidneys and thyroid, while IMRT excelled for adult heart, kidney, parotid, esophagus, and eyes. CONCLUSION: Modern radiotherapy techniques offer improved target coverage and OAR protection. However, 3D techniques are continued to be used for CSI. Notably, proton therapy stands out as the most efficient approach, closely followed by Tomotherapy in terms of achieving superior target coverage and OAR protection.


Subject(s)
Craniospinal Irradiation , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Adult , Humans , Child , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Craniospinal Irradiation/methods , Turkey , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods
3.
Asian Pac J Cancer Prev ; 25(4): 1451-1456, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38680007

ABSTRACT

OBJECTIVE: To identify swallowing-related structures (SRSs) predicting post-radiotherapy dysphagia in oropharyngeal carcinoma patients. MATERIAL AND METHODS: Between September 2020 and October 2022, oropharyngeal cancer patients who had completed radiotherapy at least one year before without recurrence or residuals were selected. They underwent flexible endoscopic evaluation of swallowing (FEES) assessments and dysphagia grading. The mean radiation doses delivered to their SRSs were recalculated. The correlation between radiation doses to each SRS and FEES scores was analysed. RESULTS: Twenty-nine participants, aged 51-73 years, were enrolled. Six patients had received two-dimensional radiotherapy, eight had undergone three-dimensional conformal radiotherapy, and fifteen had received intensity-modulated radiation therapy. Radiation doses to the inferior pharyngeal constrictor, cricopharyngeus and glottic larynx significantly predicted dysphagia for both semisolids (p = 0.023, 0.030 and 0.001) and liquid diets (p = 0.021, 0.013 and 0.002). The esophageal inlet significantly predicted swallowing outcomes for only the liquid diet (p = 0.007). CONCLUSIONS: This study supports that SRS-sparing during radiotherapy for oropharyngeal cancers improves swallowing outcomes.


Subject(s)
Deglutition Disorders , Oropharyngeal Neoplasms , Humans , Deglutition Disorders/etiology , Deglutition Disorders/radiotherapy , Middle Aged , Male , Oropharyngeal Neoplasms/radiotherapy , Oropharyngeal Neoplasms/complications , Female , Aged , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Follow-Up Studies , Prognosis , Deglutition , Radiation Injuries/etiology , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy Dosage , Organ Sparing Treatments/methods
4.
Appl Radiat Isot ; 209: 111322, 2024 Jul.
Article in English | MEDLINE | ID: mdl-38642442

ABSTRACT

Dose conformity is an essential parameter used in radiotherapy and radiosurgery that measures the correspondence of the dose distribution derived from a Treatment Planning System (TPS) with the actual volume to be treated, the Planning Treatment Volume (PTV). The present work uses a method based on the expansion of dose distributions and PTVs by three-dimensional Zernike polynomials and further comparison of their moments to define a general criterion of dose conformity. To carry on this study, data coming from 20 patients comprising 80 datasets exported from the TPS, which included imaging data (PTVs) and dose distributions corresponding to different treatment modalities: three-dimensional conformal radiotherapy, intensity-modulated radiotherapy (IMRT) and volumetric modulated arc therapy (VMAT), were used. The expansions in Zernike polynomials were obtained up to order 6 and reconstructed dose distributions and PTVs were obtained and compared, and several definitions for a general dose conformity index were proposed. Results indicate agreement between the proposed dose conformity index and the Conformation Number CN. The proposed method allows for a systematic approach to the analysis of dose distributions with further extensions in AI applications.


Subject(s)
Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Radiotherapy, Conformal/methods , Algorithms
5.
J Cancer Res Ther ; 20(1): 327-332, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-38554342

ABSTRACT

BACKGROUND: The purpose of this study was to evaluate the dosimetric benefits of carotid-sparing IMRT (intensity-modulated radiation therapy) over 3DCRT (three-dimensional conformal radiation therapy) in early glottic cancer patients. MATERIAL AND METHODS: Ten patients with histologically proven early-stage squamous cell cancer of glottis (T1N0), treated with definitive radiotherapy, were selected retrospectively for the dosimetric analysis. Patients were originally treated with 3DCRT technique. For comparison purpose, IMRT plans were generated for each patient. Dosimetric comparison was done between two techniques (IMRT and 3DCRT) in terms of PTV (planning target volume) coverage, HI (homogeneity index), CI (conformity index), and doses to right carotid artery, left carotid artery, and spinal cord. RESULTS: V95% for the PTV was higher in IMRT plans (98.26%) as compared to 3DCRT plans (95.12%) (P-value <0.001), whereas V105% for PTV was significantly higher in 3DCRT plans (16.77%) as compared to IMRT plans (0.32%) (P-value 0.11). In terms of both HI and CI, IMRT plans showed better conformity as compared to 3DCRT plans, with statistically significant difference. Both right and left carotid arteries' average mean and maximum doses were significantly lower in IMRT plans as compared to 3DCRT plans (P-value <0.001). IMRT plans resulted in significant carotid-sparing as compared to 3DCRT plans in terms of V35 and V50 (P-value <0.001). CONCLUSION: Carotid-sparing IMRT resulted in better PTV coverage and lower carotid artery dose as compared to 3DCRT in early glottic cancer patients.


Subject(s)
Laryngeal Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Laryngeal Neoplasms/radiotherapy , Retrospective Studies , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Carotid Arteries , Glottis , Radiotherapy Dosage
6.
JCO Glob Oncol ; 10: e2300478, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38484193

ABSTRACT

PURPOSE: The PARCER trial provided level I evidence for image-guided intensity-modulated radiation therapy (IG-IMRT) in patients with cervical cancer. Further information regarding long-term financial impact is imperative for adoption into the National Cancer Grid of India cervical cancer resource-stratified guidelines. METHODS: Patient data from the PARCER trial were analyzed to evaluate the cost implications of transitioning to IG-IMRT. Lacking differences in outcomes between the three-dimensional conformal radiation (3D-CRT) and IG-IMRT, differences in treatment costs, adverse event incidence, and toxicity management costs were examined. The overall financial impact was estimated by adding the treatment costs, toxicity management, and wage loss. This was extrapolated nationally to determine if a transition to IG-IMRT would be feasible for the Indian health care system. RESULTS: Of the 300 patients in the PARCER trial, 93 faced grades ≥2 adverse events (3D-CRT = 59, IG-IMRT = 34). Patients in the 3D-CRT and IG-IMRT arms spent an average of 2.39 years and 1.96 years in toxicity, respectively. The average toxicity management and the yearly financial impact per patient were, respectively, 1.50 and 1.44 times higher for 3D-CRT patients compared with IG-IMRT patients. Extrapolation to the national level showed that treatment with 3D-CRT led to a 2.88 times higher cost ratio when compared with treatment with IG-IMRT. CONCLUSION: Although the initial costs of IG-IMRT are high, on the basis of longitudinal data, it is financially inefficient to treat with 3D-CRT. Resource-stratified guidelines should include longitudinal health intervention costs rather than solely initial costs for policy decisions to implement advanced radiation technology.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Female , Humans , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Uterine Cervical Neoplasms/radiotherapy , Developing Countries , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy Dosage
7.
Phys Med ; 120: 103343, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38547546

ABSTRACT

PURPOSE: Stereotactic radiotherapy (SRT) has transformed cancer treatment, especially for brain metastases. Ensuring accurate SRT delivery is crucial, with the Winston-Lutz test being an important quality control tool. Off-axis Winston-Lutz (OAWL) tests are designed for accuracy assessment, but most are limited to fixed angles and hampered by local-field shifts caused by suboptimal Multi-Leaf Collimator (MLC) positioning. This study introduces a new OAWL approach for quality control in multi-brain-metastasis SRT. Utilizing cine Electronic Portal Imaging Device (EPID) images, it can be used with dynamic conformal arc (DCA) therapy. However, dynamic OAWL (DOAWL) is prone to more local-field shifts due to dynamic MLC movements. A two-step DOAWL is proposed: step 1 calculates local-field shifts using dynamic MLC movements in the beam-eye view data from the Treatment Planning System (TPS), while step 2 processes cine EPID images with an OAWL algorithm to isolate true deviations. METHODS: Validation involved an anthropomorphic head phantom with metallic ball-bearings, Varian TrueBeam STx accelerator delivering six coplanar/non-coplanar DCA beams, cine EPID, and ImageJ's OAWL analysis algorithm. RESULTS: Inherent local-field shifts ranged from 0.11 to 0.49 mm; corrected mean/max EPID-measured displacement was 0.34/1.03 mm. Few points exceeded 0.75/1.0-mm thresholds. CONCLUSIONS: This two-step DOAWL test merges cine-EPID acquisitions, DCA, OAWL, and advanced analysis and offers effective quality control for multi-brain-metastasis SRT. Its routine implementation may also improve physicist knowledge of the treatment precision of their machines.


Subject(s)
Brain Neoplasms , Radiosurgery , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Conformal/methods , Diagnostic Imaging , Phantoms, Imaging , Quality Control , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted
8.
Sci Rep ; 14(1): 7134, 2024 03 26.
Article in English | MEDLINE | ID: mdl-38532018

ABSTRACT

We aimed to investigate the deliverability of dynamic conformal arc therapy (DCAT) by gantry wobble owing to the intrinsic inter-segment break of the Elekta linear accelerator (LINAC) and its adverse influence on the dose to the patient. The deliverability of DCAT was evaluated according to the plan parameters, which affect the gantry rotation speed and resultant positional inaccuracies; the deliverability according to the number of control points and dose rates was investigated by using treatment machine log files and dosimetry devices, respectively. A non-negligible degradation in DCAT deliverability due to gantry wobble was observed in both the treatment machine log files and dosimetry devices. The resulting dose-delivery error occurred below a certain number of control points or above a certain dose rate. Dose simulations in the patient domain showed a similar impact on deteriorated deliverability. For targets located primarily in the isocenter, the dose differences were negligible, whereas for organs at risk located mainly off-isocenter, the dose differences were significant up to - 8.77%. To ensure safe and accurate radiotherapy, optimal plan parameters should be selected, and gantry angle-specific validations should be conducted before treatment.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Radiotherapy Planning, Computer-Assisted/methods , Particle Accelerators , Radiometry/methods , Radiotherapy, Intensity-Modulated/methods
9.
Radiother Oncol ; 195: 110258, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38537680

ABSTRACT

This systematic review examines the role of dosimetric parameters in predicting temporal lobe necrosis (TLN) risk in nasopharyngeal carcinoma (NPC) patients treated with three-dimensional conformal RT (3D-CRT), intensity-modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). TLN is a serious late complication that can adversely affect the quality of life of NPC patients. Understanding the relationship between dosimetric parameters and TLN can guide treatment planning and minimize radiation-related complications. A comprehensive search identified relevant studies published up to July 2023. Studies reporting on dosimetric parameters and TLN in NPC patients undergoing 3D-CRT, IMRT, and VMAT were included. TLN incidence, follow-up duration, and correlation with dosimetric parameters of the temporal lobe were analyzed. The review included 30 studies with median follow-up durations ranging from 28 to 110 months. The crude incidence of TLN varied from 2.3 % to 47.3 % and the average crude incidence of TLN is approximately 14 %. Dmax and D1cc emerged as potential predictors of TLN in 3D-CRT and IMRT-treated NPC patients. Threshold values of >72 Gy for Dmax and >62 Gy for D1cc were associated with increased TLN risk. However, other factors should also be considered, including host characteristics, tumor-specific features and therapeutic factors. In conclusion, this systematic review highlights the significance of dosimetric parameters, particularly Dmax and D1cc, in predicting TLN risk in NPC patients undergoing 3D-CRT, IMRT, and VMAT. The findings provide valuable insights that can help in developing optimal treatment planning strategies and contribute to the development of clinical guidelines in this field.


Subject(s)
Nasopharyngeal Carcinoma , Nasopharyngeal Neoplasms , Necrosis , Radiation Injuries , Radiotherapy, Intensity-Modulated , Temporal Lobe , Humans , Nasopharyngeal Carcinoma/radiotherapy , Nasopharyngeal Carcinoma/pathology , Temporal Lobe/radiation effects , Temporal Lobe/pathology , Necrosis/etiology , Radiation Injuries/etiology , Radiation Injuries/pathology , Nasopharyngeal Neoplasms/radiotherapy , Nasopharyngeal Neoplasms/pathology , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods
10.
Phys Med Biol ; 69(6)2024 Mar 20.
Article in English | MEDLINE | ID: mdl-38330494

ABSTRACT

Modern radiotherapy delivers highly conformal dose distributions to irregularly shaped target volumes while sparing the surrounding normal tissue. Due to the complex planning and delivery techniques, dose verification and validation of the whole treatment workflow by end-to-end tests became much more important and polymer gel dosimeters are one of the few possibilities to capture the delivered dose distribution in 3D. The basic principles and formulations of gel dosimetry and its evaluation methods are described and the available studies validating device-specific geometrical parameters as well as the dose delivery by advanced radiotherapy techniques, such as 3D-CRT/IMRT and stereotactic radiosurgery treatments, the treatment of moving targets, online-adaptive magnetic resonance-guided radiotherapy as well as proton and ion beam treatments, are reviewed. The present status and limitations as well as future challenges of polymer gel dosimetry for the validation of complex radiotherapy techniques are discussed.


Subject(s)
Polymers , Radiotherapy, Conformal , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Radiotherapy, Conformal/methods , Radiometry/methods
11.
Anticancer Res ; 44(2): 687-694, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38307577

ABSTRACT

BACKGROUND/AIM: The present study investigated the effect of respiratory motion on planned radiotherapy (RT) dose for gastric mucosa-associated lymphoid tissue (MALT) lymphoma using four-dimensional dose (4D-dose) accumulation. PATIENTS AND METHODS: 4D-computed tomography (4D-CT) images of 10 patients with gastric MALT lymphomas were divided into 10 respiratory phases. Further, the 3D-dose was calculated using 3D conformal RT (3D-CRT) and volumetric modulated arc therapy (VMAT) plans based on the average intensity projection (AIP) images. Then, both plans were recalculated according to each phase image. Moreover, the dose distributions in each phase were transferred to the AIP images using deformable image registration. The 4D-dose distribution was calculated by summing the doses of each phase, and it was compared with the dosimetric parameters of the 3D-dose distribution. RESULTS: For 3D-CRT, the D95 and D99 of the 4D-dose in the planning target volume (PTV) were significantly lower than those of the 3D-dose, with mean differences of 0.2 (p=0.009) and 0.1 Gy (p=0.021), respectively. There were no significant differences in the other PTV and organ-at-risk dosimetric parameters of 3D-CRT or in any dosimetric parameters of VMAT between the 3D- and 4D-dose distributions. CONCLUSION: The effect of respiratory motion on the planned 3D-CRT and VMAT dose distributions for gastric MALT lymphoma is minimal and clinically negligible.


Subject(s)
Lung Neoplasms , Lymphoma, B-Cell, Marginal Zone , Lymphoma, Non-Hodgkin , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Stomach Neoplasms , Humans , Lymphoma, B-Cell, Marginal Zone/diagnostic imaging , Lymphoma, B-Cell, Marginal Zone/radiotherapy , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Lung Neoplasms/radiotherapy
12.
In Vivo ; 38(2): 819-825, 2024.
Article in English | MEDLINE | ID: mdl-38418123

ABSTRACT

BACKGROUND/AIM: Radiotherapy (RT) outcomes are generally reported based on stage, patient background, and concomitant chemotherapy. This study aimed to investigate the effects of the prescribed dose to gross tumor volume (GTV) and the calculation algorithm on local control in definitive RT for head and neck (H&N) cancers using follow-up images after RT. PATIENTS AND METHODS: This study included 154 patients with H&N cancers treated by Volumetric Modulated Arc Therapy at the Kobe City Medical Center General Hospital. Patients were classified into those receiving definitive RT (70 Gy of irradiation) and those not receiving it. Follow-up images were used to categorize the patients into the responders and non-responders groups. In the non-responders group, follow-up images were imported into the treatment planning system, and the contours of the residual or recurrent areas (local failure) were extracted and fused with computed tomography-simulated images for treatment planning. Dose evaluation parameters included maximum dose, dose administered to 1% of the volume, dose administered to 50% of the volume, dose administered to 99% of the volume (D99%), and minimum dose (Dmin) administered to the GTV. The doses to the GTV were compared between responders and non-responders. RESULTS: D99% exhibited significant differences between local failure and responders and between local failure and non-responders. Dmin showed significant differences between responders and non-responders and between responders and local failure. CONCLUSION: This study emphasizes the importance of verifying dose distribution in all slices of treatment planning, highlighting the need for precise assessment of the dose to the GTV in head and neck cancers.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Head and Neck Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods
13.
Sci Rep ; 13(1): 23110, 2024 01 03.
Article in English | MEDLINE | ID: mdl-38172237

ABSTRACT

Radiation therapy is an important tool in the treatment of breast cancer and can play a crucial role in improving patient outcomes. For breast cancer, if the technique has been for a long time the use of 3DCRT, clinicians have seen the management evolve greatly in recent years. Field-in-field and IMRT approaches and more recently dynamic arctherapy are increasingly available. All of these approaches are constantly trying to improve tumour coverage and to preserve organs at risk by minimising the doses delivered to them. If arctherapy allows a considerable reduction of high doses received by healthy tissues, no one can deny that it also leads to an increase of low doses in tissues that would not have received any with other techniques. We propose a hybrid approach combining the robustness of the 3DCRT approach and the high technicality and efficiency of arctherapy. Statistical tests (ANOVA, Wilcoxon, determination coefficient, ROC, etc.) allow us to draw conclusions about the possibility of using the hybrid approach in certain cases (right breast, BMI [Formula: see text], age [Formula: see text], target volume [Formula: see text] cc, etc.). Depending on the breast laterality and patients morphological characteristics, hybridization may prove to be a therapeutic tool of choice in the management of breast cancer in radiotherapy.


Subject(s)
Breast Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Female , Breast Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/methods , Breast , Radiotherapy Dosage , Organs at Risk
14.
J Appl Clin Med Phys ; 25(3): e14284, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38295191

ABSTRACT

PURPOSE: External beam radiotherapy is a complex process, involving timely coordination among multiple teams. The aim of this study is to report our experience of establishing a standardized workflow and using quantitative data and metrics to manage the time-to-treatment initiation (TTI). METHODS AND MATERIALS: Starting in 2014, we established a standard process in a radiation oncology-specific electronic medical record system (RO-EMR) for patients receiving external beam radiation therapy in our department, aiming to measure the time interval from simulation to treatment initiation, defined as TTI, for radiation oncology. TTI data were stratified according to the following treatment techniques: three-dimensional (3D) conformal therapy, intensity-modulated radiotherapy (IMRT), and stereotactic body radiotherapy (SBRT). Statistical analysis was performed with the Mann-Whitney test for the respective metrics of aggregate data for the initial period 2012- 2015 (PI) and the later period 2016-2019 (PII). RESULT: Over 8 years, the average annual number of treatments for PI and PII were 1760 and 2357 respectively, with 3D, IMRT, and SBRT treatments accounting for 53, 29, 18% and 44, 34, 22%, respectively, of the treatment techniques. The median TTI for 3D, IMRT, and SBRT for PI and PII were 1, 6, 7, and 1, 5, 7 days, respectively, while the 90th percentile TTI for the three techniques in both periods were 5, 9, 11 and 4, 9, 10 days, respectively. From the aggregate data, the TTI was significantly reduced (p = 0.0004, p < 0.0001, p < 0.0001) from PI to PII for the three treatment techniques. CONCLUSION: Establishing a standardized workflow and frequently measuring TTI resulted in shortening the TTI during the early years (in PI) and maintaining the established TTI in the subsequent years (in PII).


Subject(s)
Radiosurgery , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy Planning, Computer-Assisted/methods , Workflow , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/methods , Radiosurgery/methods
15.
Acta Parasitol ; 69(1): 559-566, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38233676

ABSTRACT

PURPOSE: Radiotherapy showed the potential to effectively kill the cysts of pulmonary cystic echinococcosis (CE). However, little is known about its safety. This study was designed to investigate the safety of three-dimensional conformal radiotherapy (3D-CRT) on the normal lung tissue adjacent to the cyst and blood of sheep naturally infected with pulmonary CE. METHODS: Twenty pulmonary CE sheep were randomly divided into control group (n = 5) and radiation groups with a dose of 30 Gray (Gy) (n = 5), 45 Gy (n = 5), and 60 Gy (n = 5), respectively. Animals in control group received no radiation. Heat shock protein 70 (Hsp70), tumor growth factor-ß (TGF-ß), matrix metalloproteinase-2 (MMP-2) and MMP-9 in the lung tissues adjacent to the cysts, which were considered to be closely related to the pathogenesis of CE, were evaluated after 3D-CRT. A routine blood test was conducted. RESULTS: The results showed that there were multiple cysts of various sizes with protoscoleces in the lung tissues of sheep, and necrotic cysts were found after 3D-CRT. 3D-CRT significantly increased the mRNA level of Hsp70, enhanced the protein level of TGF-ß and slightly increased the expression of MMP-2 and MMP-9 in lung tissues adjacent to the cysts. 3D-CRT did not significantly alter the amount of WBC, HB and PLT in sheep blood. CONCLUSIONS: The results suggested that 3D-CRT may suppress the inflammation and induce less damage of the normal lung tissues and blood. We preliminarily showed that 3D-CRT under a safe dose may be used to treat pulmonary CE.


Subject(s)
Echinococcosis, Pulmonary , HSP70 Heat-Shock Proteins , Lung , Radiotherapy, Conformal , Sheep Diseases , Animals , Sheep , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Lung/parasitology , Lung/radiation effects , Lung/pathology , HSP70 Heat-Shock Proteins/genetics , HSP70 Heat-Shock Proteins/metabolism , Echinococcosis, Pulmonary/veterinary , Sheep Diseases/parasitology , Transforming Growth Factor beta/blood , Transforming Growth Factor beta/metabolism , Transforming Growth Factor beta/genetics , Matrix Metalloproteinase 9/metabolism , Matrix Metalloproteinase 9/blood , Matrix Metalloproteinase 2/metabolism , Matrix Metalloproteinase 2/genetics
16.
Prostate Cancer Prostatic Dis ; 27(1): 95-102, 2024 Mar.
Article in English | MEDLINE | ID: mdl-36849728

ABSTRACT

BACKGROUND: While moderately hypofractionated radiotherapy (MHRT) for prostate cancer (PC) is commonly delivered by intensity modulated radiation therapy, IMRT has not been prospectively compared to three-dimensional conformal radiotherapy (3D-CRT) in this context. We conducted a secondary analysis of the phase III RTOG 0415 trial comparing survival and toxicity outcomes for low-risk PC following MHRT with IMRT versus 3D-CRT. METHODS: RTOG 0415 was a phase III, non-inferiority trial randomizing low-risk PC patients to either MHRT or conventionally fractionated radiation with stratification by RT technique. A secondary analysis for differences in overall survival (OS), biochemical recurrence free survival (BRFS), or toxicity by EPIC scores and Common Terminology Criteria for Adverse Events (CTCAE) was performed. RESULTS: 1079 patients received the allocated intervention with a median follow up of 5.8 years. 79.1% of patients were treated with IMRT and radiation technique was balanced between arms. Across all patients, RT technique was not associated with significant differences in BRFS, OS, or rates of acute and late toxicities. For patients completing MHRT, there was a difference in the late GU toxicity distribution between 3D-CRT and IMRT but no difference in late grade 2 or greater GU or GI toxicity. Stratifying patients by RT technique and fractionation, no significant differences were observed in the minimal clinically important difference (MCID) in EPIC urinary and bowel scores following RT. CONCLUSIONS: RT technique did not impact clinical outcomes following MHRT for low-risk PC. Despite different late GU toxicity distributions in patients treated with MHRT by IMRT or 3D-CRT, there was no difference in late Grade 2 or greater GU or GI toxicity or patient reported toxicity. Increases in late GU and GI toxicity following MHRT compared to CFRT, as demonstrated in the initial publication of RTOG 0415, do not appear related to a 3D-CRT treatment technique.


Subject(s)
Prostatic Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Male , Humans , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Risk , Radiotherapy Dosage
17.
Int J Radiat Oncol Biol Phys ; 118(3): 605-615, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37816473

ABSTRACT

PURPOSE: Definitive pelvic intensity modulated radiation therapy (IMRT) in cervical cancer is susceptible to geographic miss due to daily positional and volumetric variations in target and organs at risk. Hence, despite evidence of reduced acute and late treatment-related toxicities, implementation of image-guided IMRT (IG-IMRT) with a reasonable safety margin to encompass organ motion is challenging. METHODS AND MATERIALS: In this prospective, nonrandomized phase 2 study, patients with cervical cancer International Federation of Gynecology and Obstetrics (2009) stage IB2-IIIB between the ages of 18 and 65 years were treated with definitive pelvic chemoradiotherapy with a prespecified organ (bladder and rectum) filling protocol. Reproducibility of organ filling was assessed along with the implementation of daily comprehensive adaptive image-guided radiotherapy (IGRT), with a library of 3 IMRT (volumetric modulated arc therapy) plans with incremental expansions of clinical target volume (CTV) to planning target volume (PTV) (primary) margins (small, 0.7 cm; adequate, 1 cm; and large, 1.5 cm) and a backup motion robust 3-dimensional conformal radiotherapy plan; the appropriate plan is chosen based on pretreatment cone beam computed tomography (CBCT) ("plan of the day" approach). RESULTS: Fifty patients with a median age of 49 years (IQR, 45-56 years) received definitive radiation therapy (45-46 Gy in 23-25 fractions to pelvis, with simultaneous integrated boost to gross nodes in 15 patients) with the aforementioned IGRT protocol. In the analysis of 1171 CBCT images (in 1184 treatment sessions), the mean planning computed tomography (CT) and CBCT bladder volumes were 417 and 373 cc, respectively. Significant interfractional variation in bladder volume was noted with a mean absolute dispersion of 29.5% with respect to planning CT; significant influential random factors were postchemotherapy sessions (P ≤ .001), pre-CBCT protocol duration (P = .001), and grades of chemotherapy induced nausea vomiting (P = .001). Significantly higher variation in bladder filling was noted in patients with older age (P = .014) and larger planning CT bladder volume (P ≤ .001). Time trend analysis of fraction-wise bladder volume revealed an absolute systemic reduction of 16.3% in bladder volume means from the first to the fifth week. Variation in rectal diameter was much less pronounced, with 19.2% mean dispersion and without any significant factors affecting it. Although in 19% and 2% of sessions large IMRT PTV and 3-dimensional conformal radiotherapy were necessary to cover the primary target, respectively, reduction in treated volume was possible in 43% of sessions with small PTV selection instead of standard adequate PTV (36% sessions). Plan of the day selection had a moderate to strong correlation with nonabsolute dispersion of bladder filling (Spearman ρ =0.4; P = .001) and a weak (but significant) correlation with grades of acute toxicities. The planned protocol was well tolerated with no radiation-induced local grade 3 toxicity. CONCLUSIONS: Interfractional variation in organ filling (especially bladder) is inevitable despite fixed pretreatment protocol in definitive settings (intact cervix). Despite the logistical challenges, adaptive IGRT in the form of plan of the day based on incremental CTV-to-PTV margins is a relatively simple and feasible strategy to minimize geometric uncertainties in radical IG-IMRT of cervical cancer.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Adolescent , Adult , Aged , Female , Humans , Middle Aged , Young Adult , Cone-Beam Computed Tomography , Prospective Studies , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Conformal/adverse effects , Radiotherapy, Conformal/methods , Radiotherapy, Image-Guided/adverse effects , Radiotherapy, Image-Guided/methods , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Reproducibility of Results , Uterine Cervical Neoplasms/diagnostic imaging , Uterine Cervical Neoplasms/radiotherapy
18.
Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37380796

ABSTRACT

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Subject(s)
Breast Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Breath Holding , Radiotherapy, Conformal/methods , Breast Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Organs at Risk , Unilateral Breast Neoplasms/radiotherapy
19.
Med Phys ; 51(1): 394-406, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37475544

ABSTRACT

BACKGROUND: Due to inconsistent positioning, tumor shrinking, and weight loss during fractionated treatment, the initial plan was no longer appropriate after a few fractional treatments, and the patient will require adaptive helical tomotherapy (HT) to overcome the issue. Patients are scanned with megavoltage computed tomography (MVCT) before each fractional treatment, which is utilized for patient setup and provides information for dose reconstruction. However, the low contrast and high noise of MVCT make it challenging to delineate treatment targets and organs at risk (OAR). PURPOSE: This study developed a deep-learning-based approach to generate high-quality synthetic kilovoltage computed tomography (skVCT) from MVCT and meet clinical dose requirements. METHODS: Data from 41 head and neck cancer patients were collected; 25 (2995 slices) were used for training, and 16 (1898 slices) for testing. A cycle generative adversarial network (cycleGAN) based on attention gate and residual blocks was used to generate MVCT-based skVCT. For the 16 patients, kVCT-based plans were transferred to skVCT images and electron density profile-corrected MVCT images to recalculate the dose. The quantitative indices and clinically relevant dosimetric metrics, including the mean absolute error (MAE), structural similarity index measure (SSIM), peak signal-to-noise ratio (PSNR), gamma passing rates, and dose-volume-histogram (DVH) parameters (Dmax , Dmean , Dmin ), were used to assess the skVCT images. RESULTS: The MAE, PSNR, and SSIM of MVCT were 109.6 ± 12.3 HU, 27.5 ± 1.1 dB, and 91.9% ± 1.7%, respectively, while those of skVCT were 60.6 ± 9.0 HU, 34.0 ± 1.9 dB, and 96.5% ± 1.1%. The image quality and contrast were enhanced, and the noise was reduced. The gamma passing rates improved from 98.31% ± 1.11% to 99.71% ± 0.20% (2 mm/2%) and 99.77% ± 0.18% to 99.98% ± 0.02% (3 mm/3%). No significant differences (p > 0.05) were observed in DVH parameters between kVCT and skVCT. CONCLUSION: With training on a small data set (2995 slices), the model successfully generated skVCT with improved image quality, and the dose calculation accuracy was similar to that of MVCT. MVCT-based skVCT can increase treatment accuracy and offer the possibility of implementing adaptive radiotherapy.


Subject(s)
Head and Neck Neoplasms , Radiotherapy, Conformal , Humans , Radiotherapy, Conformal/methods , Head and Neck Neoplasms/diagnostic imaging , Head and Neck Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Cone-Beam Computed Tomography , Image Processing, Computer-Assisted
20.
Cancer Res Treat ; 56(1): 1-17, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37654111

ABSTRACT

Radiotherapy (RT) is a fundamental modality in treatment of cervical cancer. With advancement of technology, conventional RT used for external beam radiotherapy (EBRT) for over half a century has been rapidly replaced with intensity-modulated radiation therapy (IMRT) especially during the last decade. This newer technique is able to differentiate the intensity of radiation within the same field, thus reduces the inevitable exposure of radiation to normal organs and enables better dose delivery to tumors. Recently, the American Society for Radiation Oncology has released a guideline for RT in cervical cancer. Although a section of the guideline recommends IMRT for the purpose of toxicity reduction, a thorough review of the literature is necessary to understand the current status of IMRT in cervical cancer. This narrative review updates the recent high-level evidences regarding the efficacy and toxicity of IMRT and provides a better understanding of the most innovative techniques currently available for EBRT enabled by IMRT.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Uterine Cervical Neoplasms , Female , Humans , Radiotherapy, Intensity-Modulated/adverse effects , Radiotherapy, Intensity-Modulated/methods , Uterine Cervical Neoplasms/pathology , Radiotherapy Dosage , Radiotherapy, Conformal/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...