Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Publication year range
1.
Front Immunol ; 12: 676354, 2021.
Article in English | MEDLINE | ID: mdl-34421893

ABSTRACT

Many adverse reactions to therapeutic drugs appear to be allergic in nature, and are thought to be triggered by patient-specific Immunoglobulin E (IgE) antibodies that recognize the drug molecules and form complexes with them that activate mast cells. However, in recent years another mechanism has been proposed, in which some drugs closely associated with allergic-type events can bypass the antibody-mediated pathway and trigger mast cell degranulation directly by activating a mast cell-specific receptor called Mas-related G protein-coupled receptor X2 (MRGPRX2). This would result in symptoms similar to IgE-mediated events, but would not require immune priming. This review will cover the frequency, severity, and dose-responsiveness of allergic-type events for several drugs shown to have MRGPRX2 agonist activity. Surprisingly, the analysis shows that mild-to-moderate events are far more common than currently appreciated. A comparison with plasma drug levels suggests that MRGPRX2 mediates many of these mild-to-moderate events. For some of these drugs, then, MRGPRX2 activation may be considered a regular and predictable feature after administration of high doses.


Subject(s)
Anaphylaxis/blood , Atracurium/adverse effects , Drug Hypersensitivity/blood , Morphine/adverse effects , Nerve Tissue Proteins/agonists , Nerve Tissue Proteins/metabolism , Receptors, G-Protein-Coupled/agonists , Receptors, G-Protein-Coupled/metabolism , Receptors, Neuropeptide/agonists , Receptors, Neuropeptide/metabolism , Rocuronium/adverse effects , Vancomycin/adverse effects , Animals , Atracurium/blood , Cell Degranulation/drug effects , Drug Hypersensitivity/immunology , Humans , Immunoglobulin E/metabolism , Mast Cells/immunology , Morphine/blood , Rocuronium/blood , Vancomycin/blood
2.
Se Pu ; 39(7): 695-701, 2021 Jul 08.
Article in Chinese | MEDLINE | ID: mdl-34227366

ABSTRACT

Vecuronium, rocuronium, and pancuronium are widely used as non-depolarizing muscle relaxants. There have been occasional cases of allergic reactions and even death when using such muscle relaxants. Rapid determination of the concentration of these muscle relaxants in blood can provide valuable information for early clinical diagnosis. As quaternary ammonium compounds, these muscle relaxants are highly polar. Hence, they cannot be retained effectively on reversed-phase chromatographic columns with conventional mobile phases. These quaternary ammonium muscle relaxants are mainly separated by ion-pair chromatography. Using an ion-pairing reagent can help improve the retention capabilities of quaternary ammonium muscle relaxants. Nevertheless, the sensitivity of MS detection is significantly decreased because of ionic inhibition caused by the ion-pairing reagent in the mobile phase. Furthermore, ion-pairing reagents can pollute the MS system. A method based on high performance liquid chromatography-tandem mass spectrometry (HPLC-MS/MS) was established for the simultaneous determination of the three quaternary ammonium muscle relaxants in blood. The blood samples were diluted and subjected to high-speed centrifugation. The supernatant was purified on a Bond Elut AL-N solid phase extraction column and then filtered through a 0.45 µm microporous membrane. The quaternary ammonium muscle relaxants were separated on a ZIC-cHILIC analytical column (50 mm×2.1 mm, 3.0 µm) with gradient elution. Acetonitrile and 0.1% formic acid aqueous solution were used as mobile phases. The separated compounds were analyzed by tandem MS with an electrospray ionization (ESI) source in positive and multiple reaction monitoring (MRM) modes. The matrix effects of vecuronium, rocuronium, and pancuronium in blood were 88.1% to 95.4%. The calibration curves for vecuronium, rocuronium, and pancuronium showed good linear relationships in each range, and all correlation coefficients (R2) were > 0.996. The limits of detection of vecuronium, rocuronium, and pancuronium were 0.2-0.8 ng/mL, with the corresponding limits of quantification being 0.5-2.0 ng/mL. The recoveries of vecuronium, rocuronium, and pancuronium were 92.8% to 110.6%, with relative standard deviations (RSDs) of 3.2%-9.4%. This method is sensitive, accurate, and easy to operate, and it can be used to rapidly determine vecuronium, rocuronium, and pancuronium in blood.


Subject(s)
Ammonium Compounds/blood , Neuromuscular Agents/blood , Chromatography, High Pressure Liquid , Humans , Pancuronium/chemistry , Rocuronium/blood , Solid Phase Extraction , Tandem Mass Spectrometry , Vecuronium Bromide/blood
4.
Biomed Chromatogr ; 33(8): e4540, 2019 Aug.
Article in English | MEDLINE | ID: mdl-30924939

ABSTRACT

The combination of propofol, ketamine and rocuronium can be used for anesthesia of ventilated rats. However, reliable pharmacokinetic models of these drugs have yet to be developed in rats, and consequently optimal infusion strategies are also unknown. Development of pharmacokinetic models requires repeated measurements of drug concentrations. In small animals, samples must be tiny to avoid excessing blood extraction. We therefore developed a drug assay system using high-performance liquid chromatography coupled with quadrupole mass spectrometry that simultaneously determines the concentration of all three drugs in just 10 µL rat plasma. We established a plasma extraction protocol, using acetonitrile as the precipitating reagent. Calibration curves were linear with R2 = 0.99 for each drug. Mean recovery from plasma was 91-93% for propofol, 89-93% for ketamine and 90-92% for rocuronium. The assay proved to be accurate for propofol 4.1-8.3%, ketamine 1.9-7.8% and rocuronium -3.6-4.7% relative error. The assay was also precise; the intra-day precisions were propofol 2.0-4.0%, ketamine 2.7-2.9% and rocuronium 2.9-3.3% relative standard deviation. Finally, the method was successfully applied to measurement the three drugs in rat plasma samples. Mean plasma concentrations with standard deviations were propofol 2.0 µg/mL ±0.5%, ketamine 3.9 µg/mL ±1.0% and rocuronium 3.2 µg/mL ±0.8% during ventilation.


Subject(s)
Chromatography, Liquid/methods , Ketamine/blood , Mass Spectrometry/methods , Propofol/blood , Rocuronium/blood , Animals , Ketamine/chemistry , Ketamine/pharmacokinetics , Limit of Detection , Linear Models , Male , Pilot Projects , Propofol/chemistry , Propofol/pharmacokinetics , Rats , Rats, Sprague-Dawley , Reproducibility of Results , Rocuronium/chemistry , Rocuronium/pharmacokinetics
SELECTION OF CITATIONS
SEARCH DETAIL
...