Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 3.241
Filter
1.
Technol Cult ; 65(1): 237-263, 2024.
Article in English | MEDLINE | ID: mdl-38661800

ABSTRACT

When the Brooklyn Waterworks opened in 1859, it was one of America's most advanced water and sewer systems. Yet after Brooklyn was annexed by New York City, the waterworks' history slipped into obscurity, despite having a now-famous champion: the "poet of America," Walt Whitman, whose brother worked on the project. This article shows the Brooklyn poet's fierce, multiyear lobbying effort for the waterworks in various newspapers and introduces a wealth of newly recovered Whitman writings on the issue. As a journalist, Whitman exemplifies the nineteenth-century press as an intermediary between expert engineers and popular readers. The poet brought precise expertise, translated engineers' technical arguments into everyday language for his readers, and fought the resulting day-to-day political battles over construction in print. Whitman, then, is an underappreciated case study of the confluence of technology, public health, and local journalism.


Subject(s)
Journalism , History, 19th Century , New York City , Journalism/history , Sanitary Engineering/history , Humans , Newspapers as Topic/history , Public Health/history
2.
Environ Sci Technol ; 58(15): 6540-6551, 2024 Apr 16.
Article in English | MEDLINE | ID: mdl-38574283

ABSTRACT

Water age in drinking water systems is often used as a proxy for water quality but is rarely used as a direct input in assessing microbial risk. This study directly linked water ages in a premise plumbing system to concentrations of Legionella pneumophila via a growth model. In turn, the L. pneumophila concentrations were used for a quantitative microbial risk assessment to calculate the associated probabilities of infection (Pinf) and clinically severe illness (Pcsi) due to showering. Risk reductions achieved by purging devices, which reduce water age, were also quantified. The median annual Pinf exceeded the commonly used 1 in 10,000 (10-4) risk benchmark in all scenarios, but the median annual Pcsi was always 1-3 orders of magnitude below 10-4. The median annual Pcsi was lower in homes with two occupants (4.7 × 10-7) than with one occupant (7.5 × 10-7) due to more frequent use of water fixtures, which reduced water ages. The median annual Pcsi for homes with one occupant was reduced by 39-43% with scheduled purging 1-2 times per day. Smart purging devices, which purge only after a certain period of nonuse, maintained these lower annual Pcsi values while reducing additional water consumption by 45-62%.


Subject(s)
Drinking Water , Legionella pneumophila , Legionella , Water Supply , Water Microbiology , Sanitary Engineering , Risk Assessment
4.
J Occup Environ Hyg ; 21(4): 259-269, 2024.
Article in English | MEDLINE | ID: mdl-38447033

ABSTRACT

Legionella pneumophila, the leading cause of Legionnaires' disease in the United States, is found in lakes, ponds, and streams but poses a health risk when it grows in building water systems. The growth of L. pneumophila in hot water systems of healthcare facilities poses a significant risk to patients, staff, and visitors. Hospitals and long-term care facilities account for 76% of reported Legionnaires' disease cases with mortality rates of 25%. Controlling L. pneumophila growth in hot water systems serving healthcare and hospitality buildings is currently achieved primarily by adding oxidizing chemical disinfectants. Chemical oxidants generate disinfection byproducts and can accelerate corrosion of premise plumbing materials and equipment. Alternative control methods that do not generate hazardous disinfection byproducts or accelerate corrosion are needed. L. pneumophila is an obligate aerobe that cannot sustain cellular respiration, amplify, or remain culturable when dissolved oxygen (DO) concentrations are too low (< 0.3 mg/L). An alternative method of controlling L. pneumophila growth by reducing DO levels in a hot water model system using a gas transfer membrane contactor was evaluated. A hot water model system was constructed and inoculated with L. pneumophila at DO concentrations above 0.5 mg/L. Once the model system was colonized, DO levels were incrementally reduced. Water samples were collected each week to evaluate the effect of reducing dissolved oxygen levels when all other conditions favored Legionella amplification. At DO concentrations below 0.3 mg/L, L. pneumophila concentrations were reduced by 1-log over 7 days. Under conditions in the hot water model system, at favorable temperatures and with no residual chlorine disinfectant, L. pneumophila concentrations were reduced by 1-log, indicating growth inhibition by reducing DO levels as the sole control measure. In sections of the model system where DO levels were not lowered L. pneumophila continued to grow. Reducing dissolved oxygen levels in hot water systems of healthcare and other large buildings to control L. pneumophila could also lower the risk of supplemental chemical treatment methods currently in use.


Subject(s)
Disinfectants , Legionella pneumophila , Legionella , Legionnaires' Disease , Humans , Legionnaires' Disease/prevention & control , Water Supply , Sanitary Engineering , Disinfectants/pharmacology , Water/pharmacology , Water Microbiology , Hot Temperature
5.
Environ Int ; 185: 108538, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38422875

ABSTRACT

Although simulated studies have provided valuable knowledge regarding the communities of planktonic bacteria and biofilms, the lack of systematic field studies have hampered the understanding of microbiology in real-world service lines and premise plumbing. In this study, the bacterial communities of water and biofilm were explored, with a special focus on the lifetime development of biofilm communities and their key influencing factors. The 16S rRNA gene sequencing results showed that both the planktonic bacteria and biofilm were dominated by Proteobacteria. Among the 15,084 observed amplicon sequence variants (ASVs), the 33 core ASVs covered 72.8 %, while the 12 shared core ASVs accounted for 62.2 % of the total sequences. Remarkably, it was found that the species richness and diversity of biofilm communities correlated with pipe age. The relative abundance of ASV2 (f_Sphingomonadaceae) was lower for pipe ages 40-50 years (7.9 %) than for pipe ages 10-20 years (59.3 %), while the relative abundance of ASV10 (f_Hyphomonadaceae) was higher for pipe ages 40-50 years (19.5 %) than its presence at pipe ages 20-30 years (1.9 %). The community of the premise plumbing biofilm had significantly higher species richness and diversity than that of the service line, while the steel-plastics composite pipe interior lined with polyethylene (S-PE) harbored significantly more diverse biofilm than the galvanized steel pipes (S-Zn). Interestingly, S-PE was enriched with ASV27 (g_Mycobacterium), while S-Zn pipes were enriched with ASV13 (g_Pseudomonas). Moreover, the network analysis showed that five rare ASVs, not core ASVs, were keystone members in biofilm communities, indicating the importance of rare members in the function and stability of biofilm communities. This manuscript provides novel insights into real-world service lines and premise plumbing microbiology, regarding lifetime dynamics (pipe age 10-50 years), and the influences of pipe types (premise plumbing vs. service line) and pipe materials (S-Zn vs. S-PE).


Subject(s)
Drinking Water , Sanitary Engineering , Water Supply , RNA, Ribosomal, 16S/genetics , Water Microbiology , Bacteria/genetics , Biofilms , Steel , Drinking Water/microbiology
6.
Water Res ; 251: 121098, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38219686

ABSTRACT

Manual flushing of building plumbing is commonly used to address water quality issues that arise from water stagnation. Autonomous flushing informed by sensors has the potential to aid in the management of building plumbing, but a number of knowledge gaps hinder its application. This study evaluates autonomous flushing of building plumbing with online sensor and actuator nodes deployed under kitchen sinks in five residential houses. Online oxidation-reduction potential (ORP) and temperature data were collected for nine weeks during the winter and summer in houses with both free chlorine and chloramine. ORP levels in houses with free chlorine residuals decreased after overnight stagnation. The overnight decrease in ORP was not observed when tap water was automatically flushed for five minutes at 6:00 h every morning. ORP levels in houses with chloramine residuals did not decrease consistently after overnight stagnation, and daily automated flushes did not have an observable effect on the ORP signals. Additional laboratory experiments were carried out to evaluate ORP signals during chlorine decay and after incremental changes in chlorine, as would be expected in building plumbing conditions. Results from the lab and field deployments suggest on-line ORP sensors may be used to detect free chlorine decay due to stagnating water, but are not as effective in detecting chloramine decay. However, field results also suggest ORP may not respond as expected on a timely manner after free chlorine or chloramine have been restored, hindering their applicability in developing control algorithms. In this paper we tested twice-daily five-minute automatic flushing and found that it counteracts water quality degradation associated with overnight stagnation in free chlorine systems. An automatic sensor-based flushing is proposed using online temperature sensor data to determine when flushing has reached water from the main. The results suggest that flushing informed by temperature sensors can reduce the flushing time by 46 % compared to the preset five-minute static flush.


Subject(s)
Drinking Water , Sanitary Engineering , Water Supply , Chloramines , Chlorine , Temperature , Oxidation-Reduction
7.
Environ Sci Technol ; 58(4): 2038-2047, 2024 Jan 30.
Article in English | MEDLINE | ID: mdl-38241248

ABSTRACT

Single-particle inductively coupled plasma mass spectrometry (spICP-MS) has been used to characterize metallic nanoparticles (NPs) assuming that all NPs are spherical and composed of pure element. However, environmental NPs generally do not meet these criteria, suggesting that spICP-MS may underestimate their true sizes. This study employed a system hyphenating the atomizer (ATM), differential mobility analyzer (DMA), and spICP-MS to characterize metallic NPs in tap water. Its performance was validated by using reference Au nanoparticles (AuNPs) and Ag-shelled AuNPs. The hyphenated system can determine the actual size and metal composition of both NPs with additional heating after ATM, while stand-alone spICP-MS misidentified the Ag-shelled AuNPs as smaller individual AgNPs and AuNPs. Dissolved metal ions could introduce artifact NPs after heating but could be eliminated by centrifugation. The hyphenated system was applied to characterize Fe-containing and Pb-containing NPs resulting from the corrosion of plumbing materials in tap water. The mode sizes of Fe-containing and Pb-containing NPs were determined to be 110 and 100 nm and the particle number concentrations were determined to be 4.99 × 107 and 1.40 × 106 #/mL, respectively. Cautions should be paid to potential changes in particle size induced by heating for metallic NPs with a low melting point or a high organic content.


Subject(s)
Metal Nanoparticles , Metal Nanoparticles/chemistry , Gold/chemistry , Lead , Sanitary Engineering , Corrosion , Nebulizers and Vaporizers , Particle Size , Water
8.
Am J Infect Control ; 52(3): 337-343, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37778710

ABSTRACT

BACKGROUND: Aquatic opportunistic pathogen Aeromonas hydrophila, known to persist in low-nutrient chlorinated waters, can cause life-threatening infections. Two intensive care units experienced a cluster of Aeromonas infections following outdoor temperature spikes coinciding with recurrent plumbing issues, with fatalities due to severe underlying comorbidities co-occurring with extensively-drug resistant (XDR) Aeromonas. METHODS: We investigated this cluster using whole genome sequencing to assess genetic relatedness of isolates and identify antimicrobial resistance determinants. Three A. hydrophila were isolated from patients staying in or adjacent to rooms with plumbing issues during or immediately after periods of elevated outdoor temperatures. Sinks and faucets were swabbed for culture. RESULTS: All A. hydrophila clinical isolates exhibited carbapenem resistance but were not genetically related. Diverse resistance determinants corresponding to extensively-drug resistant were found, including co-occurring KPC-3 and VIM-2, OXA-232, and chromosomal CphA-like carbapenemase genes, contributing to major treatment challenges. All 3 patients were treated with multiple antibiotic regimens to overcome various carbapenemase classes and expired due to underlying comorbidities. Environmental culture yielded no Aeromonas. CONCLUSIONS: While the investigation revealed no singular source of contamination, it supports a possible link between plumbing issues, elevated outdoor temperatures and incidence of nosocomial Aeromonas infections. The diversity of carbapenemase genes detected in these wastewater-derived Aeromonas warrants heightened infection prevention precautions during periods of plumbing problems especially with heat waves.


Subject(s)
Aeromonas , Bacterial Proteins , Cross Infection , Humans , Aeromonas hydrophila/genetics , Sanitary Engineering , Cross Infection/epidemiology , Hot Temperature , beta-Lactamases/genetics , Aeromonas/genetics , Anti-Bacterial Agents , Microbial Sensitivity Tests
9.
Environ Sci Technol ; 57(50): 21382-21394, 2023 Dec 19.
Article in English | MEDLINE | ID: mdl-38071676

ABSTRACT

In-building disinfectants are commonly applied to control the growth of pathogens in plumbing, particularly in facilities such as hospitals that house vulnerable populations. However, their application has not been well optimized, especially with respect to interactive effects with pipe materials and potential unintended effects, such as enrichment of antibiotic resistance genes (ARGs) across the microbial community. Here, we used triplicate convectively mixed pipe reactors consisting of three pipe materials (PVC, copper, and iron) for replicated simulation of the distal reaches of premise plumbing and evaluated the effects of incrementally increased doses of chlorine, chloramine, chlorine dioxide, and copper-silver disinfectants. We used shotgun metagenomic sequencing to characterize the resulting succession of the corresponding microbiomes over the course of 37 weeks. We found that both disinfectants and pipe material affected ARG and microbial community taxonomic composition both independently and interactively. Water quality and total bacterial numbers were not found to be predictive of pathogenic species markers. One result of particular concern was the tendency of disinfectants, especially monochloramine, to enrich ARGs. Metagenome assembly indicated that many ARGs were enriched specifically among the pathogenic species. Functional gene analysis was indicative of a response of the microbes to oxidative stress, which is known to co/cross-select for antibiotic resistance. These findings emphasize the need for a holistic evaluation of pathogen control strategies for plumbing.


Subject(s)
Disinfectants , Drinking Water , Sanitary Engineering , Disinfectants/pharmacology , Water Supply , Anti-Bacterial Agents/pharmacology , Copper , Cell Proliferation
10.
Mol Ecol ; 32(20): 5590-5608, 2023 10.
Article in English | MEDLINE | ID: mdl-37728237

ABSTRACT

Mesophotic coral ecosystems (MCEs) are tropical reefs found at depths of ~30-150 m, below the region most heavily impacted by heat stress and other disturbances. Hence, MCEs may serve as potential refugia for threatened shallow reefs, but they also harbour depth-endemic fauna distinct from shallow reefs. Previous studies have characterized biodiversity patterns along depth gradients, but focussed primarily on conspicuous taxa (fishes, corals, etc.). Environmental DNA (eDNA) metabarcoding offers a more holistic approach to assess biodiversity patterns across the tree of life. Here, we use three metabarcoding assays targeting fishes (16S rRNA), eukaryotes (18S rDNA) and metazoans (COI) to assess biodiversity change from the surface to ~90 m depth across 15-m intervals at three sites within the Hawaiian Archipelago. We observed significant community differences between most depth zones, with distinct zonation centred at 45-60 m for eukaryotes and metazoans, but not for fishes. This finding may be attributable to the higher mobility of reef fishes, although methodological limitations are likely a contributing factor. The possibility for MCEs to serve as refugia is not excluded for fishes, but invertebrate communities >45 m are distinct, indicating limited connectivity for the majority of reef fauna. This study provides a new approach for surveying biodiversity on MCEs, revealing patterns in a much broader context than the limited-taxon studies that comprise the bulk of our present knowledge.


Subject(s)
Anthozoa , DNA, Environmental , Animals , Coral Reefs , Ecosystem , DNA, Environmental/genetics , Sanitary Engineering , RNA, Ribosomal, 16S , Biodiversity , Anthozoa/genetics , Fishes/genetics
11.
Environ Pollut ; 337: 122520, 2023 Nov 15.
Article in English | MEDLINE | ID: mdl-37678732

ABSTRACT

Despite being corrosion-resistant, plastic potable water pipes might accumulate heavy metals on their surface if they convey metal-contaminated tap water. This study examined the influence of water pH and flow conditions on lead (Pb) release from new and biofilm-laden potable water pipes to provide insights regarding decontamination. For this purpose, biofilms were grown onto new crosslinked polyethylene (PEX-A), high-density polyethylene (HDPE), and copper pipes for three months. Lead was then deposited onto the new and biofilm-laden pipes through 5 d exposure experiments under flow conditions. After that, lead release experiments were conducted by exposing the lead-accumulated pipes to lead-free synthetic tap water for 5 d, under both stagnant and water flow conditions. The metal accumulation study showed no significant difference in lead uptake by new pipes and their biofilm-laden counterparts under flow conditions. This could be attributed to the detachment of biofilms that have accumulated lead as water flows through the pipes. Water flow conditions significantly influenced the lead release from new and biofilm-laden water pipes. A lower water pH of 5.0 increased the release of lead from plastic pipes into the contact water, compared to pH 6.0 and 7.8. The greatest percentage of lead was released from biofilm-laden HDPE pipes (5.3%, 120 h) compared to biofilm-laden copper pipes (3.9%, 6 h) and PEX-A (3.7%, 120 h) and after exposure to lead-free synthetic tap water at pH 5.0, under stagnant conditions. On the other hand, under water flow conditions, the greatest lead release was found for new PEX-A pipes (4.4%, 120 h), new HDPE pipes (2.7%, 120 h), and biofilm-laden copper pipes (3.7%, 2 h).


Subject(s)
Drinking Water , Sanitary Engineering , Copper/analysis , Lead , Water Supply , Polyethylene , Decontamination , Biofilms
12.
Environ Sci Pollut Res Int ; 30(41): 94878-94889, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37542688

ABSTRACT

The microbial community of the landfill undergoing aerobic stabilization process by aeration engineering was investigated. The municipal solid wastes (MSWs) were sampled from two aeration well sites with different landfill temperatures (65.5°C and 41.7°C) under higher and lower stabilization level. The physical component, chemical property, and microbial population of MSWs were analyzed and compared. The result showed that the phylum Firmicutes was dominant in the aerobic landfill; and the genus Weissella and Syntrophaceticus were more abundant in high, and low temperature site, respectively. The bacterial distribution showed difference on two temperature sites and four landfill depths, mainly affected by the ammonia-nitrogen and moisture content of MSWs. The ecological profiles of the microorganisms responded the aeration engineering were predicted. The anaerobic hydrolytic and acetogenic microorganisms were decreased in abundance, while the facultative Lactobacillus increased when the landfill under a higher stabilization level. The function abundances of methane oxidation, sulfide oxidation, and aerobic chemoheterotrophy were enriched by aeration engineering, which was the microbial mechanism for accelerating the stabilization process of landfill.


Subject(s)
Bacteria , Oxygen , Waste Disposal Facilities , Solid Waste , Beijing , Bacteria/classification , Bacteria/metabolism , Sanitary Engineering/methods , Biodegradation, Environmental
13.
Environ Sci Technol ; 57(36): 13612-13624, 2023 09 12.
Article in English | MEDLINE | ID: mdl-37643149

ABSTRACT

Hot water building plumbing systems are vulnerable to the proliferation of opportunistic pathogens (OPs), including Legionella pneumophila and Mycobacterium avium. Implementation of copper as a disinfectant could help reduce OPs, but a mechanistic understanding of the effects on the microbial community under real-world plumbing conditions is lacking. Here, we carried out a controlled pilot-scale study of hot water systems and applied shotgun metagenomic sequencing to examine the effects of copper dose (0-2 mg/L), orthophosphate corrosion control agent, and water heater anode materials (aluminum vs magnesium vs powered anode) on the bulk water and biofilm microbiome composition. Metagenomic analysis revealed that, even though a copper dose of 1.2 mg/L was required to reduce Legionella and Mycobacterium numbers, lower doses (e.g., ≤0.6 mg/L) measurably impacted the broader microbial community, indicating that the OP strains colonizing these systems were highly copper tolerant. Orthophosphate addition reduced bioavailability of copper, both to OPs and to the broader microbiome. Functional gene analysis indicated that both membrane damage and interruption of nucleic acid replication are likely at play in copper inactivation mechanisms. This study identifies key factors (e.g., orthophosphate, copper resistance, and anode materials) that can confound the efficacy of copper for controlling OPs in hot water plumbing.


Subject(s)
Microbiota , Water , Copper , Metagenomics , Sanitary Engineering , Electrodes , Phosphates
14.
J Water Health ; 21(7): 884-894, 2023 Jul.
Article in English | MEDLINE | ID: mdl-37515560

ABSTRACT

Legionella concentrations in drinking water have been regulated for decades and are evaluated with regard to their concentrations in drinking water plumbing systems (DWPS). The respective action levels differ at the international level. In Germany, the Federal Environment Agency (UBA) specifies the application of ISO 11731 for the detection of legionella in drinking water and gives a binding recommendation for the methods to be used for culturing and evaluation. Effective from 01 March 2019, the UBA recommendation was revised. The utilized culture media in the culture approach were altered, consequently affecting the spectrum of legionella colonies detected in drinking water. Using data from a routine legionella monitoring of a large laboratory, over a period of 6 years and 17,270 individual drinking water samples, allowed us to assess the impact of the alteration on the assessment of DWPS. By comparing the amount of action level exceedances before and after the method change, it could be demonstrated that exceedances are reported significantly more often under the new method. Consequently, the corresponding action level for evaluation of legionella contamination and the resulting risk to human health needs to be revised to avoid the misleading impression of increased health risk.


Subject(s)
Drinking Water , Legionella pneumophila , Legionella , Humans , Drinking Water/analysis , Water Microbiology , Sanitary Engineering , Germany , Water Supply
15.
Water Res ; 241: 120149, 2023 Aug 01.
Article in English | MEDLINE | ID: mdl-37270942

ABSTRACT

Premise plumbing plays an essential role in determining the final quality of drinking water consumed by customers. However, little is known about the influences of plumbing configuration on water quality changes. This study selected parallel premise plumbing in the same building with different configurations, i.e., laboratory and toilet plumbing. Water quality deteriorations induced by premise plumbing under regular and interrupted water supply were investigated. The results showed that most of the water quality parameters did not vary under regular supply, except Zn, which was significantly increased by laboratory plumbing (78.2 to 260.7 µg/l). For the bacterial community, the Chao1 index was significantly increased by both plumbing types to a similar level (52 to 104). Laboratory plumbing significantly changed the bacterial community, but toilet plumbing did not. Remarkably, water supply interruption/restoration led to serious water quality deterioration in both plumbing types but resulted in different changes. Physiochemically, discoloration was observed only in laboratory plumbing, along with sharp increases in Mn and Zn. Microbiologically, the increase in ATP was sharper in toilet plumbing than in laboratory plumbing. Some opportunistic pathogen-containing genera, e.g., Legionella spp. and Pseudomonas spp., were present in both plumbing types but only in disturbed samples. This study highlighted the esthetic, chemical, and microbiological risks associated with premise plumbing, for which system configuration plays an important role. Attention should be given to optimizing premise plumbing design for managing building water quality.


Subject(s)
Sanitary Engineering , Water Quality , Water Microbiology , Water Supply , Pseudomonas
16.
Zebrafish ; 20(3): 122-125, 2023 06.
Article in English | MEDLINE | ID: mdl-37310180

ABSTRACT

One of the greatest expenses in running a zebrafish laboratory is the aquatic systems used for housing. These critical pieces of equipment are essential and incorporate components undergoing constant activity in pumping water, monitoring, dosing, and filtration. The systems available on the market are robust, yet ongoing activity eventually leads to the need for repair or replacement. Moreover, some systems are no longer commercially available, impairing the ability to service this critical infrastructure. In this study, we demonstrate a do it yourself (DIY) method to re-engineer an aquatic system's pumps and plumbing, which hybridizes a system no longer commercially available with components used by active vendors. This transition from a two external pump Aquatic Habitat/Pentair design to an individual submerged pump Aquaneering-like plan saves funds by expanding infrastructure longevity. Our hybridized configuration has been in uninterrupted use for >3 years, supporting zebrafish health and high fecundity.


Subject(s)
Sanitary Engineering , Zebrafish , Animals , Fertility , Laboratories , Longevity
17.
Antimicrob Resist Infect Control ; 12(1): 58, 2023 06 19.
Article in English | MEDLINE | ID: mdl-37337245

ABSTRACT

BACKGROUND: Accumulating evidence shows a role of the hospital wastewater system in the spread of multidrug-resistant organisms, such as carbapenemase producing Enterobacterales (CPE). Several sequential outbreaks of CPE on the geriatric ward of the Ghent University hospital have led to an outbreak investigation. Focusing on OXA-48 producing Citrobacter freundii, the most prevalent species, we aimed to track clonal relatedness using whole genome sequencing (WGS). By exploring transmission routes we wanted to improve understanding and (re)introduce targeted preventive measures. METHODS: Environmental screening (toilet water, sink and shower drains) was performed between 2017 and 2021. A retrospective selection was made of 53 Citrobacter freundii screening isolates (30 patients and 23 environmental samples). DNA from frozen bacterial isolates was extracted and prepped for shotgun WGS. Core genome multilocus sequence typing was performed with an in-house developed scheme using 3,004 loci. RESULTS: The CPE positivity rate of environmental screening samples was 19.0% (73/385). Highest percentages were found in the shower drain samples (38.2%) and the toilet water samples (25.0%). Sink drain samples showed least CPE positivity (3.3%). The WGS data revealed long-term co-existence of three patient sample derived C. freundii clusters. The biggest cluster (ST22) connects 12 patients and 8 environmental isolates taken between 2018 and 2021 spread across the ward. In an overlapping period, another cluster (ST170) links eight patients and four toilet water isolates connected to the same room. The third C. freundii cluster (ST421) connects two patients hospitalised in the same room but over a period of one and a half year. Additional sampling in 2022 revealed clonal isolates linked to the two largest clusters (ST22, ST170) in the wastewater collection pipes connecting the rooms. CONCLUSIONS: Our findings suggest long-term circulation and transmission of carbapenemase producing C. freundii clones in hospital sanitary installations despite surveillance, daily cleaning and intermittent disinfection protocols. We propose a role for the wastewater drainage system in the spread within and between rooms and for the sanitary installations in the indirect transmission via bioaerosol plumes. To tackle this problem, a multidisciplinary approach is necessary including careful design and maintenance of the plumbing system.


Subject(s)
Citrobacter freundii , Wastewater , Humans , Aged , Citrobacter freundii/genetics , Sanitary Engineering , Retrospective Studies , Hospitals , Clone Cells
18.
Mol Ther ; 31(6): 1577-1595, 2023 06 07.
Article in English | MEDLINE | ID: mdl-37165619

ABSTRACT

Next-generation sequencing has revealed that less than 2% of transcribed genes are translated into proteins, with a large portion transcribed into noncoding RNAs (ncRNAs). Among these, long noncoding RNAs (lncRNAs) represent the largest group and are pervasively transcribed throughout the genome. Dysfunctions in lncRNAs have been found in various diseases, highlighting their potential as therapeutic, diagnostic, and prognostic targets. However, challenges, such as unknown molecular mechanisms and nonspecific immune responses, and issues of drug specificity and delivery present obstacles in translating lncRNAs into clinical applications. In this review, we summarize recent publications that have explored lncRNA functions in human diseases. We also discuss challenges and future directions for developing lncRNA treatments, aiming to bridge the gap between functional studies and clinical potential and inspire further exploration in the field.


Subject(s)
RNA, Long Noncoding , Humans , RNA, Long Noncoding/metabolism , Sanitary Engineering , RNA, Untranslated
19.
Environ Sci Technol ; 57(16): 6360-6372, 2023 04 25.
Article in English | MEDLINE | ID: mdl-37036108

ABSTRACT

Residential buildings provide unique conditions for opportunistic premise plumbing pathogen (OPPP) exposure via aerosolized water droplets produced by showerheads, faucets, and tubs. The objective of this review was to critically evaluate the existing literature that assessed the impact of potentially enhancing conditions to OPPP occurrence associated with residential plumbing and to point out knowledge gaps. Comprehensive studies on the topic were found to be lacking. Major knowledge gaps identified include the assessment of OPPP growth in the residential plumbing, from building entry to fixtures, and evaluation of the extent of the impact of typical residential plumbing design (e.g., trunk and branch and manifold), components (e.g., valves and fixtures), water heater types and temperature setting of operation, and common pipe materials (copper, PEX, and PVC/CPVC). In addition, impacts of the current plumbing code requirements on OPPP responses have not been assessed by any study and a lack of guidelines for OPPP risk management in residences was identified. Finally, the research required to expand knowledge on OPPP amplification in residences was discussed.


Subject(s)
Drinking Water , Sanitary Engineering , Water Supply , Housing , Water Microbiology
20.
Environ Sci Technol ; 57(13): 5453-5463, 2023 04 04.
Article in English | MEDLINE | ID: mdl-36952669

ABSTRACT

Microbial communities in premise plumbing systems were investigated after more than 2 months of long-term stagnation, during a subsequent flushing event, and during post-flush stagnation. Water samples were collected from showers in buildings supplied with chlorinated groundwater, untreated groundwater, and chloraminated surface water. The building supplied with chlorinated groundwater generally had the lowest bacterial concentrations across all sites (ranging from below quantification limit to 5.2 log copies/L). For buildings supplied with untreated groundwater, bacterial concentrations (5.0 to 7.6 log copies/L) and microbial community diversity index (ACE) values were consistent throughout sampling. Nontuberculous mycobacteria (NTM) and Legionella pneumophila were not detected in any groundwater-supplied buildings. Total bacteria, Legionella spp., and NTM were abundant in the surface water-supplied buildings following long-term stagnation (up to 7.6, 6.2, and 7.6 log copies/L, respectively). Flushing decreased these concentrations by ∼1 to >4 log units and reduced microbial community diversity, but the communities largely recovered within a week of post-flush stagnation. The results suggest that buildings supplied with disinfected surface water are more likely than buildings supplied with treated or untreated groundwater to experience deleterious changes in microbiological water quality during stagnation and that the water quality improvements from flushing with chloraminated water, while substantial, are short-lived.


Subject(s)
Drinking Water , Groundwater , Legionella pneumophila , Legionella , Water Quality , Water Supply , Sanitary Engineering , Water Microbiology
SELECTION OF CITATIONS
SEARCH DETAIL
...