Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 16.709
Filter
1.
PLoS One ; 19(5): e0302828, 2024.
Article in English | MEDLINE | ID: mdl-38722930

ABSTRACT

Cupping therapy is a popular intervention for improving muscle recovery after exercise although clinical evidence is weak. Previous studies demonstrated that cupping therapy may improve microcirculation of the soft tissue to accelerate tissue healing. However, it is unclear whether the cupping size could affect the spatial hemodynamic response of the treated muscle. The objective of this study was to use 8-channel near-infrared spectroscopy to assess this clinical question by assessing the effect of 3 cupping sizes (35, 40, and 45 mm in inner diameter of the circular cup) under -300 mmHg for 5 min on the muscle hemodynamic response from the area inside and outside the cup, including oxyhemoglobin and deoxy-hemoglobin in 18 healthy adults. Two-way factorial design was used to assess the interaction between the cupping size (35, 40, and 45 mm) and the location (inside and outside the cup) and the main effects of the cupping size and the location. The two-way repeated measures ANOVA demonstrated an interaction between the cupping size and the location in deoxy-hemoglobin (P = 0.039) but no interaction in oxyhemoglobin (P = 0.100), and a main effect of the cup size (P = 0.001) and location (P = 0.023) factors in oxyhemoglobin. For the cupping size factor, the 45-mm cup resulted in a significant increase in oxyhemoglobin (5.738±0.760 µM) compared to the 40-mm (2.095±0.312 µM, P<0.001) and 35-mm (3.134±0.515 µM, P<0.01) cup. Our findings demonstrate that the cupping size and location factors affect the muscle hemodynamic response, and the use of multi-channel near-infrared spectroscopy may help understand benefits of cupping therapy on managing musculoskeletal impairment.


Subject(s)
Hemodynamics , Muscle, Skeletal , Oxyhemoglobins , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Hemodynamics/physiology , Female , Adult , Muscle, Skeletal/physiology , Muscle, Skeletal/blood supply , Oxyhemoglobins/metabolism , Oxyhemoglobins/analysis , Cupping Therapy/methods , Young Adult , Hemoglobins/metabolism
2.
BMJ Open ; 14(5): e079858, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724058

ABSTRACT

INTRODUCTION: Anastomotic leakage (AL) is defined as the failure of complete healing or disruption of the anastomosis subsequent to rectal cancer surgery, resulting in the extravasation of intestinal contents into the intra-abdominal or pelvic cavity. It is a serious complication of rectal cancer surgery, accounting for a considerable increase in morbidity and mortality. The use of fluorescence imaging technology in surgery allows surgeons to better evaluate blood perfusion. However, the conclusions of some existing studies are not consistent, so a consensus on whether the near-infrared indocyanine green (NIR-ICG) imaging system can reduce the incidence of AL is needed. METHODS: This POSTER trial is designed as a multicentre, prospective, randomised controlled clinical study adhering to the "population, interventions, comparisons, outcomes (PICO)" principles. It is scheduled to take place from August 2019 to December 2024 across eight esteemed hospitals in China. The target population consists of patients diagnosed with rectal cancer through pathological confirmation, with tumours located≤10 cm from the anal verge, eligible for laparoscopic surgery. Enrolled patients will be randomly assigned to either the intervention group or the control group. The intervention group will receive intravenous injections of ICG twice, with intraoperative assessment of anastomotic blood flow using the near-infrared NIR-ICG system during total mesorectal excision (TME) surgery. Conversely, the control group will undergo conventional TME surgery without the use of the NIR-ICG system. A 30-day follow-up period postoperation will be conducted to monitor and evaluate occurrences of AL. The primary endpoint of this study is the incidence of AL within 30 days postsurgery in both groups. The primary outcome investigators will be blinded to the application of ICG angiography. Based on prior literature, we hypothesise an AL rate of 10.3% in the control group and 3% in the experimental group for this study. With a planned ratio of 2:1 between the number of cases in the experimental and control groups, and an expected 20% lost-to-follow-up rate, the initial estimated sample size for this study is 712, comprising 474 in the experimental group and 238 in the control group. ETHICS AND DISSEMINATION: This study has been approved by Ethics committee of Beijing Friendship Hospital, Capital Medical University (approval number: 2019-P2-055-02). The results will be disseminated in major international conferences and peer-reviewed journals. TRIAL REGISTRATION NUMBER: NCT04012645.


Subject(s)
Anastomotic Leak , Indocyanine Green , Laparoscopy , Rectal Neoplasms , Humans , Indocyanine Green/administration & dosage , Rectal Neoplasms/surgery , Rectal Neoplasms/diagnostic imaging , Laparoscopy/methods , Prospective Studies , Anastomotic Leak/prevention & control , Coloring Agents , Female , Multicenter Studies as Topic , Randomized Controlled Trials as Topic , Male , China , Spectroscopy, Near-Infrared/methods , Adult , Middle Aged
3.
Food Res Int ; 186: 114401, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38729704

ABSTRACT

Fuzhuan brick tea (FBT) fungal fermentation is a key factor in achieving its unique dark color, aroma, and taste. Therefore, it is essential to develop a rapid and reliable method that could assess its quality during FBT fermentation process. This study focused on using electronic nose (e-nose) and spectroscopy combination with sensory evaluations and physicochemical measurements for building machine learning (ML) models of FBT. The results showed that the fused data achieved 100 % accuracy in classifying the FBT fermentation process. The SPA-MLR method was the best prediction model for FBT quality (R2 = 0.95, RMSEP = 0.07, RPD = 4.23), and the fermentation process was visualized. Where, it was effectively detecting the degree of fermentation relationship with the quality characteristics. In conclusion, the current study's novelty comes from the established real-time method that could sensitively detect the unique post-fermentation quality components based on the integration of spectral, and e-nose and ML approaches.


Subject(s)
Electronic Nose , Fermentation , Spectroscopy, Near-Infrared , Taste , Tea , Tea/chemistry , Tea/microbiology , Spectroscopy, Near-Infrared/methods , Odorants/analysis , Chemometrics/methods , Humans , Fungi/metabolism , Machine Learning , Volatile Organic Compounds/analysis
4.
Food Res Int ; 186: 114320, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38729710

ABSTRACT

High-moisture extrusion (HME) is widely used to produce meat analogues. During HME the plant-based materials experience thermal and mechanical stresses. It is complicated to separate their effects on the final products because these effects are interrelated. In this study we hypothesize that the intensity of the thermal treatment can explain a large part of the physicochemical changes that occur during extrusion. For this reason, near-infrared (NIR) spectroscopy was used as a novel method to quantify the thermal process intensity during HME. High-temperature shear cell (HTSC) processing was used to create a partial least squares (PLS) regression curve for processing temperature under controlled processing conditions (root mean standard error of cross-validation (RMSECV) = 4.00 °C, coefficient of determination of cross-validation (R2CV) = 0.97). This PLS regression model was then applied to HME extrudates produced at different screw speeds (200-1200 rpm) and barrel temperatures (100-160 °C) with two different screw profiles to calculate the equivalent shear cell temperature as a measure for thermal process intensity. This equivalent shear cell temperature reflects the effects of changes in local temperature conditions, residence time and thermal stresses. Furthermore, it can be related to the degree of texturization of the extrudates. This information can be used to gain new insights into the effect of various process parameters during HME on the thermal process intensity and extrudate quality.


Subject(s)
Food Handling , Hot Temperature , Soybean Proteins , Spectroscopy, Near-Infrared , Spectroscopy, Near-Infrared/methods , Food Handling/methods , Soybean Proteins/chemistry , Soybean Proteins/analysis , Least-Squares Analysis , Water/chemistry
5.
J Neuroeng Rehabil ; 21(1): 78, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38745322

ABSTRACT

BACKGROUND: Mirror therapy (MT) has been shown to be effective for motor recovery of the upper limb after a stroke. The cerebral mechanisms of mirror therapy involve the precuneus, premotor cortex and primary motor cortex. Activation of the precuneus could be a marker of this effectiveness. MT has some limitations and video therapy (VT) tools are being developed to optimise MT. While the clinical superiority of these new tools remains to be demonstrated, comparing the cerebral mechanisms of these different modalities will provide a better understanding of the related neuroplasticity mechanisms. METHODS: Thirty-three right-handed healthy individuals were included in this study. Participants were equipped with a near-infrared spectroscopy headset covering the precuneus, the premotor cortex and the primary motor cortex of each hemisphere. Each participant performed 3 tasks: a MT task (right hand movement and left visual feedback), a VT task (left visual feedback only) and a control task (right hand movement only). Perception of illusion was rated for MT and VT by asking participants to rate the intensity using a visual analogue scale. The aim of this study was to compare brain activation during MT and VT. We also evaluated the correlation between the precuneus activation and the illusion quality of the visual mirrored feedback. RESULTS: We found a greater activation of the precuneus contralateral to the visual feedback during VT than during MT. We also showed that activation of primary motor cortex and premotor cortex contralateral to visual feedback was more extensive in VT than in MT. Illusion perception was not correlated with precuneus activation. CONCLUSION: VT led to greater activation of a parieto-frontal network than MT. This could result from a greater focus on visual feedback and a reduction in interhemispheric inhibition in VT because of the absence of an associated motor task. These results suggest that VT could promote neuroplasticity mechanisms in people with brain lesions more efficiently than MT. CLINICAL TRIAL REGISTRATION: NCT04738851.


Subject(s)
Feedback, Sensory , Motor Cortex , Spectroscopy, Near-Infrared , Humans , Male , Female , Spectroscopy, Near-Infrared/methods , Adult , Feedback, Sensory/physiology , Motor Cortex/physiology , Motor Cortex/diagnostic imaging , Young Adult , Brain/physiology , Brain/diagnostic imaging , Parietal Lobe/physiology , Parietal Lobe/diagnostic imaging , Psychomotor Performance/physiology
6.
J Biomed Opt ; 29(Suppl 3): S33302, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38707651

ABSTRACT

Significance: Cerebral oximeters have the potential to detect abnormal cerebral blood oxygenation to allow for early intervention. However, current commercial systems have two major limitations: (1) spatial coverage of only the frontal region, assuming that surgery-related hemodynamic effects are global and (2) susceptibility to extracerebral signal contamination inherent to continuous-wave near-infrared spectroscopy (NIRS). Aim: This work aimed to assess the feasibility of a high-density, time-resolved (tr) NIRS device (Kernel Flow) to monitor regional oxygenation changes across the cerebral cortex during surgery. Approach: The Flow system was assessed using two protocols. First, digital carotid compression was applied to healthy volunteers to cause a rapid oxygenation decrease across the ipsilateral hemisphere without affecting the contralateral side. Next, the system was used on patients undergoing shoulder surgery to provide continuous monitoring of cerebral oxygenation. In both protocols, the improved depth sensitivity of trNIRS was investigated by applying moment analysis. A dynamic wavelet filtering approach was also developed to remove observed temperature-induced signal drifts. Results: In the first protocol (28±5 years; five females, five males), hair significantly impacted regional sensitivity; however, the enhanced depth sensitivity of trNIRS was able to separate brain and scalp responses in the frontal region. Regional sensitivity was improved in the clinical study given the age-related reduction in hair density of the patients (65±15 years; 14 females, 13 males). In five patients who received phenylephrine to treat hypotension, different scalp and brain oxygenation responses were apparent, although no regional differences were observed. Conclusions: The Kernel Flow has promise as an intraoperative neuromonitoring device. Although regional sensitivity was affected by hair color and density, enhanced depth sensitivity of trNIRS was able to resolve differences in scalp and brain oxygenation responses in both protocols.


Subject(s)
Cerebrovascular Circulation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Spectroscopy, Near-Infrared/instrumentation , Female , Male , Adult , Cerebrovascular Circulation/physiology , Hemodynamics/physiology , Oximetry/methods , Oximetry/instrumentation , Oxygen/blood , Oxygen/metabolism , Brain/diagnostic imaging , Brain/blood supply , Equipment Design
7.
Cereb Cortex ; 34(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38725293

ABSTRACT

Numerous studies reported inconsistent results concerning gender influences on the functional organization of the brain for language in children and adults. However, data for the gender differences in the functional language networks at birth are sparse. Therefore, we investigated gender differences in resting-state functional connectivity in the language-related brain regions in newborns using functional near-infrared spectroscopy. The results revealed that female newborns demonstrated significantly stronger functional connectivities between the superior temporal gyri and middle temporal gyri, the superior temporal gyri and the Broca's area in the right hemisphere, as well as between the right superior temporal gyri and left Broca's area. Nevertheless, statistical analysis failed to reveal functional lateralization of the language-related brain areas in resting state in both groups. Together, these results suggest that the onset of language system might start earlier in females, because stronger functional connectivities in the right brain in female neonates were probably shaped by the processing of prosodic information, which mainly constitutes newborns' first experiences of speech in the womb. More exposure to segmental information after birth may lead to strengthened functional connectivities in the language system in both groups, resulting in a stronger leftward lateralization in males and a more balanced or leftward dominance in females.


Subject(s)
Language , Sex Characteristics , Spectroscopy, Near-Infrared , Humans , Female , Spectroscopy, Near-Infrared/methods , Male , Infant, Newborn , Brain/physiology , Brain/diagnostic imaging , Rest/physiology , Functional Laterality/physiology , Neural Pathways/physiology , Brain Mapping/methods
8.
Sci Rep ; 14(1): 10426, 2024 05 07.
Article in English | MEDLINE | ID: mdl-38714752

ABSTRACT

Discriminating different cultivars of maca powder (MP) and detecting their authenticity after adulteration with potent adulterants such as maize and soy flour is a challenge that has not been studied with non-invasive techniques such as near infrared spectroscopy (NIRS). This study developed models to rapidly classify and predict 0, 10, 20, 30, 40, and 50% w/w of soybean and maize flour in red, black and yellow maca cultivars using a handheld spectrophotometer and chemometrics. Soy and maize adulteration of yellow MP was classified with better accuracy than in red MP, suggesting that red MP may be a more susceptible target for adulteration. Soy flour was discovered to be a more potent adulterant compared to maize flour. Using 18 different pretreatments, MP could be authenticated with R2CV in the range 0.91-0.95, RMSECV 6.81-9.16 g/,100 g and RPD 3.45-4.60. The results show the potential of NIRS for monitoring Maca quality.


Subject(s)
Machine Learning , Powders , Spectroscopy, Near-Infrared , Zea mays , Spectroscopy, Near-Infrared/methods , Zea mays/chemistry , Spectrophotometry/methods , Macau , Food Contamination/analysis , Glycine max/chemistry , Flour/analysis
9.
PLoS One ; 19(5): e0301041, 2024.
Article in English | MEDLINE | ID: mdl-38701088

ABSTRACT

OBJECTIVE: To evaluate the safety and performance of an implantable near-infrared (NIR) spectroscopy sensor for multi-metabolite monitoring of glucose, ketones, lactate, and ethanol. RESEARCH DESIGN AND METHODS: This is an early feasibility study (GLOW, NCT04782934) including 7 participants (4 with type 1 diabetes (T1D), 3 healthy volunteers) in whom the YANG NIR spectroscopy sensor (Indigo) was implanted for 28 days. Metabolic challenges were used to vary glucose levels (40-400 mg/dL, 2.2-22.2 mmol/L) and/or induce increases in ketones (ketone drink, up to 3.5 mM), lactate (exercise bike, up to 13 mM) and ethanol (4-8 alcoholic beverages, 40-80g). NIR spectra for glucose, ketones, lactate, and ethanol levels analyzed with partial least squares regression were compared with blood values for glucose (Biosen EKF), ketones and lactate (GlucoMen LX Plus), and breath ethanol levels (ACE II Breathalyzer). The effect of potential confounders on glucose measurements (paracetamol, aspartame, acetylsalicylic acid, ibuprofen, sorbitol, caffeine, fructose, vitamin C) was investigated in T1D participants. RESULTS: The implanted YANG sensor was safe and well tolerated and did not cause any infectious or wound healing complications. Six out 7 sensors remained fully operational over the entire study period. Glucose measurements were sufficiently accurate (overall mean absolute (relative) difference MARD of 7.4%, MAD 8.8 mg/dl) without significant impact of confounders. MAD values were 0.12 mM for ketones, 0.16 mM for lactate, and 0.18 mM for ethanol. CONCLUSIONS: The first implantable multi-biomarker sensor was shown to be well tolerated and produce accurate measurements of glucose, ketones, lactate, and ethanol. TRIAL REGISTRATION: Clinical trial identifier: NCT04782934.


Subject(s)
Ethanol , Feasibility Studies , Ketones , Lactic Acid , Spectroscopy, Near-Infrared , Humans , Ketones/analysis , Male , Ethanol/analysis , Spectroscopy, Near-Infrared/methods , Adult , Female , Lactic Acid/analysis , Lactic Acid/blood , Blood Glucose/analysis , Middle Aged , Diabetes Mellitus, Type 1/blood , Biosensing Techniques/methods , Biosensing Techniques/instrumentation , Glucose/analysis
10.
PLoS One ; 19(5): e0302375, 2024.
Article in English | MEDLINE | ID: mdl-38701103

ABSTRACT

There are numerous reports of enhanced or emerged visual arts abilities in patients with semantic impairment. These reports led to the theory that a loss of function on the language side of the brain can result in changes of ability to draw and/or to paint. Further, the left posterior middle temporal gyrus (l-pMTG) has been revealed to contribute to the higher control semantic mechanisms with objects recognition and integration of visual information, within a widely distributed network of the left hemisphere. Nevertheless, the theory has not been fully studied in neural bases. The aim of this study is to examine role of the l-pMTG on shape recognition and its reconstruction within drawing behavior, by using a combining method of the repetitive transcranial magnetic stimulation (rTMS) and functional near-infrared spectroscopy (fNIRS). Eighteen healthy participants received a low frequency inhibitory rTMS to their l-pMTG during the drawing task of the Benton Visual Retention Test (BVRT). There was a significant decrease of the mean accuracy of reproductions in the Complex designs of the BVRT, compared to the Simple and Medium designs. The fNIRS data showed strong negative correlations with the results of the BVRT. Though our hypothesis had a contradiction that rTMS would have inhibited the brain activity in the stimulated site, the results suggest that shape recognition and its reconstruction such as the BVRT require neural activations of the l-TL as well as that of the l-pMTG.


Subject(s)
Spectroscopy, Near-Infrared , Temporal Lobe , Transcranial Magnetic Stimulation , Humans , Transcranial Magnetic Stimulation/methods , Temporal Lobe/physiology , Temporal Lobe/diagnostic imaging , Spectroscopy, Near-Infrared/methods , Male , Female , Adult , Young Adult , Pattern Recognition, Visual/physiology , Brain Mapping/methods
11.
Phys Chem Chem Phys ; 26(19): 14228-14243, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38690612

ABSTRACT

The development of chromophores that absorb in the near-infrared (NIR) region beyond 1000 nm underpins numerous applications in medical and energy sciences, yet also presents substantial challenges to molecular design and chemical synthesis. Here, the core bacteriochlorin chromophore of nature's NIR absorbers, bacteriochlorophylls, has been adapted and tailored by annulation in an effort to achieve absorption in the NIR-II region. The resulting bacteriochlorin, Phen2,1-BC, contains two annulated naphthalene groups spanning meso,ß-positions of the bacteriochlorin and the 1,2-positions of the naphthalene. Phen2,1-BC was prepared via a new synthetic route. Phen2,1-BC is an isomer of previously examined Phen-BC, which differs only in attachment via the 1,8-positions of the naphthalene. Despite identical π-systems, the two bacteriochlorins have distinct spectroscopic and photophysical features. Phen-BC has long-wavelength absorption maximum (912 nm), oscillator strength (1.0), and S1 excited-state lifetime (150 ps) much different than Phen2,1-BC (1292 nm, 0.23, and 0.4 ps, respectively). These two molecules and an analogue with intermediate characteristics bearing annulated phenyl rings have unexpected properties relative to those of non-annulated counterparts. Understanding the distinctions requires extending concepts beyond the four-orbital-model description of tetrapyrrole spectroscopic features. In particular, a reduction in symmetry resulting from annulation results in electronic mixing of x- and y-polarized transitions/states, as well as vibronic coupling that together reduce oscillator strength of the long-wavelength absorption manifold and shorten the S1 excited-state lifetime. Collectively, the results suggest a heuristic for the molecular design of tetrapyrrole chromophores for deep penetration into the relatively unutilized NIR-II region.


Subject(s)
Porphyrins , Spectroscopy, Near-Infrared , Porphyrins/chemistry , Naphthalenes/chemistry , Molecular Structure , Bacteriochlorophylls/chemistry
12.
Opt Lett ; 49(10): 2669-2672, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38748132

ABSTRACT

Central venous oxygen saturation (ScvO2) is an important parameter for assessing global oxygen usage and guiding clinical interventions. However, measuring ScvO2 requires invasive catheterization. As an alternative, we aim to noninvasively and continuously measure changes in oxygen saturation of the internal jugular vein (SijvO2) by a multi-channel near-infrared spectroscopy system. The relation between the measured reflectance and changes in SijvO2 is modeled by Monte Carlo simulations and used to build a prediction model using deep neural networks (DNNs). The prediction model is tested with simulated data to show robustness to individual variations in tissue optical properties. The proposed technique is promising to provide a noninvasive tool for monitoring the stability of brain oxygenation in broad patient populations.


Subject(s)
Jugular Veins , Monte Carlo Method , Oxygen Saturation , Jugular Veins/physiology , Humans , Oxygen Saturation/physiology , Neural Networks, Computer , Oxygen/metabolism , Spectroscopy, Near-Infrared/methods , Male
13.
Article in English | MEDLINE | ID: mdl-38717876

ABSTRACT

Neurovascular coupling (NVC) provides important insights into the intricate activity of brain functioning and may aid in the early diagnosis of brain diseases. Emerging evidences have shown that NVC could be assessed by the coupling between electroencephalography (EEG) and functional near-infrared spectroscopy (fNIRS). However, this endeavor presents significant challenges due to the absence of standardized methodologies and reliable techniques for coupling analysis of these two modalities. In this study, we introduced a novel method, i.e., the collaborative multi-output variational Gaussian process convergent cross-mapping (CMVGP-CCM) approach to advance coupling analysis of EEG and fNIRS. To validate the robustness and reliability of the CMVGP-CCM method, we conducted extensive experiments using chaotic time series models with varying noise levels, sequence lengths, and causal driving strengths. In addition, we employed the CMVGP-CCM method to explore the NVC between EEG and fNIRS signals collected from 26 healthy participants using a working memory (WM) task. Results revealed a significant causal effect of EEG signals, particularly the delta, theta, and alpha frequency bands, on the fNIRS signals during WM. This influence was notably observed in the frontal lobe, and its strength exhibited a decline as cognitive demands increased. This study illuminates the complex connections between brain electrical activity and cerebral blood flow, offering new insights into the underlying NVC mechanisms of WM.


Subject(s)
Algorithms , Electroencephalography , Memory, Short-Term , Neurovascular Coupling , Spectroscopy, Near-Infrared , Humans , Electroencephalography/methods , Male , Female , Spectroscopy, Near-Infrared/methods , Adult , Normal Distribution , Neurovascular Coupling/physiology , Young Adult , Memory, Short-Term/physiology , Healthy Volunteers , Reproducibility of Results , Multivariate Analysis , Frontal Lobe/physiology , Frontal Lobe/diagnostic imaging , Brain Mapping/methods , Theta Rhythm/physiology , Brain/physiology , Brain/diagnostic imaging , Brain/blood supply , Nonlinear Dynamics , Delta Rhythm/physiology , Alpha Rhythm/physiology
14.
Crit Care Explor ; 6(5): e1094, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38727717

ABSTRACT

OBJECTIVES: Near-infrared spectroscopy (NIRS) is a potentially valuable modality to monitor the adequacy of oxygen delivery to the brain and other tissues in critically ill patients, but little is known about the physiologic determinants of NIRS-derived tissue oxygen saturations. The purpose of this study was to assess the contribution of routinely measured physiologic parameters to tissue oxygen saturation measured by NIRS. DESIGN: An observational sub-study of patients enrolled in the Role of Active Deresuscitation After Resuscitation-2 (RADAR-2) randomized feasibility trial. SETTING: Two ICUs in the United Kingdom. PATIENTS: Patients were recruited for the RADAR-2 study, which compared a conservative approach to fluid therapy and deresuscitation with usual care. Those included in this sub-study underwent continuous NIRS monitoring of cerebral oxygen saturations (SctO2) and quadriceps muscle tissue saturations (SmtO2). INTERVENTION: Synchronized and continuous mean arterial pressure (MAP), heart rate (HR), and pulse oximetry (oxygen saturation, Spo2) measurements were recorded alongside NIRS data. Arterial Paco2, Pao2, and hemoglobin concentration were recorded 12 hourly. Linear mixed effect models were used to investigate the association between these physiologic variables and cerebral and muscle tissue oxygen saturations. MEASUREMENTS AND MAIN RESULTS: Sixty-six patients were included in the analysis. Linear mixed models demonstrated that Paco2, Spo2, MAP, and HR were weakly associated with SctO2 but only explained 7.1% of the total variation. Spo2 and MAP were associated with SmtO2, but together only explained 0.8% of its total variation. The remaining variability was predominantly accounted for by between-subject differences. CONCLUSIONS: Our findings demonstrated that only a small proportion of variability in NIRS-derived cerebral and tissue oximetry measurements could be explained by routinely measured physiologic variables. We conclude that for NIRS to be a useful monitoring modality in critical care, considerable further research is required to understand physiologic determinants and prognostic significance.


Subject(s)
Critical Illness , Oximetry , Oxygen Saturation , Spectroscopy, Near-Infrared , Humans , Spectroscopy, Near-Infrared/methods , Male , Female , Oxygen Saturation/physiology , Middle Aged , Aged , Oximetry/methods , Monitoring, Physiologic/methods , Brain/metabolism , Brain/blood supply , United Kingdom , Oxygen/metabolism , Oxygen/blood , Oxygen/analysis , Intensive Care Units , Quadriceps Muscle/metabolism , Quadriceps Muscle/blood supply
15.
PLoS One ; 19(5): e0303144, 2024.
Article in English | MEDLINE | ID: mdl-38718035

ABSTRACT

Charitable fundraising increasingly relies on online crowdfunding platforms. Project images of charitable crowdfunding use emotional appeals to promote helping behavior. Negative emotions are commonly used to motivate helping behavior because the image of a happy child may not motivate donors to donate as willingly. However, some research has found that happy images can be more beneficial. These contradictory results suggest that the emotional valence of project imagery and how fundraisers frame project images effectively remain debatable. Thus, we compared and analyzed brain activation differences in the prefrontal cortex governing human emotions depending on donation decisions using functional near-infrared spectroscopy, a neuroimaging device. We advance existing theory on charitable behavior by demonstrating that little correlation exists in donation intentions and brain activity between negative and positive project images, which is consistent with survey results on donation intentions by victim image. We also discovered quantitative brain hemodynamic signal variations between donors and nondonors, which can predict and detect donor mental brain functioning using functional connectivity, that is, the statistical dependence between the time series of electrophysiological activity and oxygenated hemodynamic levels in the prefrontal cortex. These findings are critical in developing future marketing strategies for online charitable crowdfunding platforms, especially project images.


Subject(s)
Emotions , Fund Raising , Spectroscopy, Near-Infrared , Humans , Emotions/physiology , Spectroscopy, Near-Infrared/methods , Fund Raising/methods , Female , Male , Adult , Charities , Prefrontal Cortex/physiology , Prefrontal Cortex/diagnostic imaging , Intention , Young Adult , Brain Mapping/methods , Crowdsourcing , Brain/physiology , Brain/diagnostic imaging
16.
Cereb Cortex ; 34(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38715408

ABSTRACT

Speech comprehension in noise depends on complex interactions between peripheral sensory and central cognitive systems. Despite having normal peripheral hearing, older adults show difficulties in speech comprehension. It remains unclear whether the brain's neural responses could indicate aging. The current study examined whether individual brain activation during speech perception in different listening environments could predict age. We applied functional near-infrared spectroscopy to 93 normal-hearing human adults (20 to 70 years old) during a sentence listening task, which contained a quiet condition and 4 different signal-to-noise ratios (SNR = 10, 5, 0, -5 dB) noisy conditions. A data-driven approach, the region-based brain-age predictive modeling was adopted. We observed a significant behavioral decrease with age under the 4 noisy conditions, but not under the quiet condition. Brain activations in SNR = 10 dB listening condition could successfully predict individual's age. Moreover, we found that the bilateral visual sensory cortex, left dorsal speech pathway, left cerebellum, right temporal-parietal junction area, right homolog Wernicke's area, and right middle temporal gyrus contributed most to prediction performance. These results demonstrate that the activations of regions about sensory-motor mapping of sound, especially in noisy conditions, could be sensitive measures for age prediction than external behavior measures.


Subject(s)
Aging , Brain , Comprehension , Noise , Spectroscopy, Near-Infrared , Speech Perception , Humans , Adult , Speech Perception/physiology , Male , Female , Spectroscopy, Near-Infrared/methods , Middle Aged , Young Adult , Aged , Comprehension/physiology , Brain/physiology , Brain/diagnostic imaging , Aging/physiology , Brain Mapping/methods , Acoustic Stimulation/methods
17.
Sci Rep ; 14(1): 9996, 2024 05 01.
Article in English | MEDLINE | ID: mdl-38693184

ABSTRACT

Tracking a moving object with the eyes seems like a simple task but involves areas of prefrontal cortex (PFC) associated with attention, working memory and prediction. Increasing the demand on these processes with secondary tasks can affect eye movements and/or perceptual judgments. This is particularly evident in chronic or acute neurological conditions such as Alzheimer's disease or mild traumatic brain injury. Here, we combined near infrared spectroscopy and video-oculography to examine the effects of concurrent upper limb movement, which provides additional afference and efference that facilitates tracking of a moving object, in a novel dual-task pursuit protocol. We confirmed the expected effects on judgement accuracy in the primary and secondary tasks, as well as a reduction in eye velocity when the moving object was occluded. Although there was limited evidence of oculo-manual facilitation on behavioural measures, performing concurrent upper limb movement did result in lower activity in left medial PFC, as well as a change in PFC network organisation, which was shown by Graph analysis to be locally and globally more efficient. These findings extend upon previous work by showing how PFC is functionally organised to support eye-hand coordination when task demands more closely replicate daily activities.


Subject(s)
Prefrontal Cortex , Upper Extremity , Humans , Prefrontal Cortex/physiology , Male , Female , Upper Extremity/physiology , Adult , Young Adult , Movement/physiology , Psychomotor Performance/physiology , Eye Movements/physiology , Spectroscopy, Near-Infrared , Attention/physiology
18.
Med Eng Phys ; 127: 104170, 2024 May.
Article in English | MEDLINE | ID: mdl-38692767

ABSTRACT

Recently, functional Near-Infrared Spectroscopy (fNIRS) was applied to obtain, non-invasively, the human peri­spinal Neuro-Vascular Response (NVR) under a non-noxious electrical stimulation of a peripheral nerve. This method allowed the measurements of changes in the concentration of oxyhemoglobin (O2Hb) and deoxyhemoglobin (HHb) from the peri­spinal vascular network. However, there is a lack of clarity about the potential differences in perispinal NVR recorded by the different fNIRS technologies currently available. In this work, the two main noninvasive fNIRS technologies were compared, i.e., LED and LASER-based. The recording of the human peri­spinal NVR induced by non-noxious electrical stimulation of a peripheral nerve was recorded simultaneously at C7 and T10 vertebral levels. The amplitude, rise time, and full width at half maximum duration of the perispinal NVRs were characterized in healthy volunteers and compared between both systems. The main difference was that the LED-based system shows about one order of magnitude higher values of amplitude than the LASER-based system. No statistical differences were found for rise time and for duration parameters (at thoracic level). The comparison of point-to-point wave patterns did not show significant differences between both systems. In conclusion, the peri­spinal NRV response obtained by different fNIRS technologies was reproducible, and only the amplitude showed differences, probably due to the power of the system which should be considered when assessing the human peri­spinal vascular network.


Subject(s)
Lasers , Spectroscopy, Near-Infrared , Spinal Cord , Humans , Spectroscopy, Near-Infrared/methods , Male , Spinal Cord/blood supply , Spinal Cord/diagnostic imaging , Spinal Cord/physiology , Adult , Female , Young Adult , Electric Stimulation , Hemoglobins/analysis , Hemoglobins/metabolism
19.
Cereb Cortex ; 34(13): 104-111, 2024 May 02.
Article in English | MEDLINE | ID: mdl-38696603

ABSTRACT

Autism is characterized by atypical social communication styles. To investigate whether individuals with high autistic traits could still have effective social communication among each other, we compared the behavioral patterns and communication quality within 64 dyads of college students paired with both high, both low, and mixed high-low (HL) autistic traits, with their gender matched. Results revealed that the high-high (HH) autistic dyads exhibited atypical behavioral patterns during conversations, including reduced mutual gaze, communicational turns, and emotional sharing compared with the low-low and/or HL autistic dyads. However, the HH autistic dyads displayed enhanced interpersonal neural synchronization during social communications measured by functional near-infrared spectroscopy, suggesting an effective communication style. Besides, they also provided more positive subjective evaluations of the conversations. These findings highlight the potential for alternative pathways to effectively communicate with the autistic community, contribute to a deeper understanding of how high autistic traits influence social communication dynamics among autistic individuals, and provide important insights for the clinical practices for supporting autistic people.


Subject(s)
Autistic Disorder , Communication , Spectroscopy, Near-Infrared , Humans , Male , Female , Young Adult , Autistic Disorder/psychology , Autistic Disorder/physiopathology , Interpersonal Relations , Social Behavior , Social Interaction , Brain/physiopathology , Brain/physiology , Adult , Cortical Synchronization/physiology , Adolescent
20.
Luminescence ; 39(5): e4762, 2024 May.
Article in English | MEDLINE | ID: mdl-38698695

ABSTRACT

Broadband near-infrared (NIR) spectroscopy has gained significant attention due to its versatile application in various fields. In the realm of NIR phosphors, Fe3+ ion is an excellent activator known for its nontoxic and harmless nature. In this study, we prepared an Fe3+-activated SrGa12O19 (SGO) NIR phosphor and analyzed its phase and luminescence properties. Upon excitation at 326 nm, the SGO:Fe3+ phosphor exhibited a broadband emission in the range 700-1000 nm, peaking at 816 nm. The optical band gap of SGO:Fe3+ was evaluated. To enhance the long-lasting phosphorescence, an oxygen vacancy-rich SGO:Fe3+ (VO-SGO:Fe3+) sample was prepared for activation. Interestingly, the increase in the oxygen-vacancy concentration indeed contributed to the activation of persistent luminescence of Fe3+ ions. The VO-SGO:Fe3+ sample has a long duration and high charge storage capacity, allowing it to perform efficiently in various applications. This work provides the foundation for further design of Cr3+-free PersL phosphors with efficient NIR PersL.


Subject(s)
Luminescence , Luminescent Agents , Oxygen , Oxygen/chemistry , Luminescent Agents/chemistry , Strontium/chemistry , Luminescent Measurements , Ferric Compounds/chemistry , Gallium/chemistry , Iron/chemistry , Spectroscopy, Near-Infrared
SELECTION OF CITATIONS
SEARCH DETAIL
...