Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.678
Filter
1.
J Orthop Surg Res ; 19(1): 282, 2024 May 06.
Article in English | MEDLINE | ID: mdl-38711065

ABSTRACT

BACKGROUND: The aim of this study was to compare the effects of four different immobilization methods [single sugar tong splint (SSTS), double sugar tong splint (DSTS), short arm cast (SAC), and long arm cast (LAC)] commonly used for restricting forearm rotation in the upper extremity. METHODS: Forty healthy volunteers were included in the study. Dominant extremities were used for measurements. Basal pronation and supination of the forearm were measured with a custom-made goniometer, and the total rotation arc was calculated without any immobilization. Next, the measurements were repeated with the SAC, LAC, SSTS and DSTS. Each measurement was compared to the baseline value, and the percentage of rotation restriction was calculated. RESULTS: The most superior restriction rates were observed for the LAC (p = 0.00). No statistically significant difference was detected between the SSTS and DSTS in terms of the restriction of supination, pronation or the rotation arc (p values, 1.00, 0.18, and 0.50, respectively). Statistically significant differences were not detected between the SAC and the SSTS in any of the three parameters (p values, 0.25; 1.00; 1.00, respectively). When the SAC and DSTS were compared, while there was no significant difference between the two methods in pronation (p = 0.50), a statistically significant difference was detected in supination (p = 0.01) and in the total rotation arc (p = 0.03). CONCLUSION: The LAC provides superior results in restricting forearm rotation. The SAC and SSTS had similar effects on forearm rotation. The DSTS, which contains, in addition to the SSTS, a sugar tong portion above the elbow, does not provide additional rotational stability.


Subject(s)
Forearm , Immobilization , Splints , Humans , Male , Female , Adult , Rotation , Forearm/physiology , Young Adult , Immobilization/methods , Supination/physiology , Pronation/physiology , Casts, Surgical , Healthy Volunteers , Range of Motion, Articular/physiology
2.
BMC Musculoskelet Disord ; 25(1): 348, 2024 May 03.
Article in English | MEDLINE | ID: mdl-38702659

ABSTRACT

OBJECTIVE: To compare the treatment effectiveness of digitized and 3D-printed repositioning splints with that of conventional repositioning splints in the treatment of anterior displacement of the temporomandibular joint disc. METHODS: This retrospective study included 96 patients with disc displacement of the anterior temporomandibular joint. They were treated with either digitally designed and 3D-printed repositioning splints or traditional splints and followed up for at least six months. Changes in signs and symptoms such as pain and mouth opening before and after treatment were recorded to evaluate treatment outcomes. RESULTS: During the first month of treatment, both the digitally designed and 3D-printed repositioning splint groups (Group B) and the traditional repositioning splint group (Group A) showed significant increases in mouth opening, with increases of 4.93 ± 3.06 mm and 4.07 ± 4.69 mm, respectively, and there was no significant difference between the two groups. Both groups had a significant reduction in visual analog scale (VAS) pain scores, with Group B showing a greater reduction of 1.946 ± 1.113 compared to 1.488 ± 0.978 in Group A (P < 0.05). By the sixth month, Group B's mouth opening further improved to 38.65 ± 3.22 mm (P < 0.05), while Group A's mouth opening did not significantly improve. Regarding pain, Group A's VAS score decreased by 0.463 ± 0.778 after one month, and Group B's score decreased by 0.455 ± 0.715; both groups showed significant reductions, but there was no significant difference between the two groups. CONCLUSION: Compared with traditional repositioning splints, digitally designed and 3D-printed repositioning splints are more effective at reducing patient pain and improving mouth opening. 3D-printed repositioning splints are an effective treatment method for temporomandibular joint disc displacement and have significant potential for widespread clinical application.


Subject(s)
Joint Dislocations , Printing, Three-Dimensional , Temporomandibular Joint Disc , Temporomandibular Joint Disorders , Humans , Male , Retrospective Studies , Female , Adult , Temporomandibular Joint Disc/physiopathology , Middle Aged , Temporomandibular Joint Disorders/therapy , Treatment Outcome , Joint Dislocations/therapy , Occlusal Splints , Young Adult , Pain Measurement , Range of Motion, Articular , Splints
3.
Wiad Lek ; 77(3): 462-471, 2024.
Article in English | MEDLINE | ID: mdl-38691788

ABSTRACT

OBJECTIVE: Aim: To study the specifics of the impact of immediate intraoperative loading with a splinting component on supporting tissues during a one-stage implantation protocol. PATIENTS AND METHODS: Materials and Methods: In the course of the study, orthopedic treatment was carried out for 55 patients aged 29 to 60 years. The following were performed: cone-beam computed tomography, software planning and intraoral scanning with an optical scanner, one-stage implantation protocol, assessment of implant stability with the Osstell ISQ device, microcirculation study in the peri-implant area using laser Doppler flowmetry (LDF). RESULTS: Results: It was established that around loaded implants there is an increase in blood flow and vasomotor activity of the microcirculatory channel of the supporting tissues, an increase in the volume of bone tissue and an increase in torque, which is the optimal forecast for the acceleration of the pace of osseointegration. CONCLUSION: Conclusions: The use of a splinting component during immediate intraoperative functional masticatory load accelerates the dynamics of bone tissue remodeling processes around the implant, which is an optimal prediction of osseointegration rates in various dental implantation protocols and is consistent with high values of the implant stability coefficient.


Subject(s)
Immediate Dental Implant Loading , Humans , Middle Aged , Adult , Male , Female , Splints , Osseointegration , Dental Implants , Dental Implantation, Endosseous/methods , Cone-Beam Computed Tomography
4.
BMC Musculoskelet Disord ; 25(1): 261, 2024 Apr 03.
Article in English | MEDLINE | ID: mdl-38570756

ABSTRACT

BACKGROUND: Non-operative management is typically indicated for extra-articular distal radius fractures. Conservative treatments such as Sugar tong splints (STs) and Muenster splints (MUs) are commonly used. However, there is limited research and outcome data comparing the two splint types. Therefore, this study aimed to investigate and compare the radiographic and clinical outcomes of treatment using STs and MUs. METHODS: In this retrospective comparative study, we aimed to evaluate and compare the radiographic and clinical outcomes of STs and MUs for the treatment of distal radius fractures. The study included 64 patients who underwent closed reduction (CR) in the emergency room and were treated with either STs or MUs splints (STs group: n = 38, MUs group: n = 26). Initial X-rays, post-CR X-rays, and last outpatient follow-up X-rays were evaluated. Radial height (RH), ulnar variance (UV), radial inclination (RI), and volar tilt (VT) were measured by a blinded investigator. The Quick DASH form was applied to measure patients' satisfaction after treatments. RESULTS: There were no significant differences in baseline characteristics, initial radiographic measurements, or radiographic measurements immediately after CR between the two groups. However, the overall radiological values deteriorated to some degree in both groups compared to the post-CR images. Furthermore, using a paired test, the STs group showed significant differences in RH and RI, and the MUs group showed significant differences in RH and UV between the last follow-up and post-CR images. CONCLUSIONS: The study concluded that there was no difference in clinical outcomes between the two splint types. However, both STs and MUs groups showed reduced radiographic parameters, and the MUs group showed a significant reduction of RH and UV in the treatment of distal radius fractures. LEVEL OF EVIDENCE: Level IV; Retrospective Comparison; Treatment Study.


Subject(s)
Radius Fractures , Wrist Fractures , Humans , Treatment Outcome , Retrospective Studies , Splints , Sugars , Radius Fractures/therapy , Radius Fractures/surgery , Range of Motion, Articular , Bone Plates , Fracture Fixation, Internal/methods
6.
Niger J Clin Pract ; 27(4): 430-434, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38679763

ABSTRACT

BACKGROUND: Various types of nasal tampons are used for packing after septoplasty. Intranasal splints are widely used as they are more advantageous than other materials regarding the lower complication rates of synechia, and lesser pain during removal. However, there is no consensus on the timing of intranasal splint removal after septoplasty operations. AIM: In this study, we aimed to investigate the effects of removal time of intranasal splints on postoperative complications after septoplasty. METHODS: One hundred patients who had septoplasty were randomly divided into two groups according to splint removal time. In group I, the splints were removed on the third postoperative day and in group II, splints were removed on the seventh postoperative day. Pain during splint removal was evaluated by visual analog scale (VAS). Complications of hemorrhage, septal hematoma, crusting, mucosal injury, and infection were recorded during splint removal and compared. In the first postoperative month, hemorrhage, crusting, mucosal injury, infection, synechia, and in the second postoperative month, synechia and perforation rates were compared between two groups. RESULTS: Mucosal crusting was significantly higher in group II during splint removal. There was no statistically significant difference between the two groups regarding the complication rates and pain scores. Our findings showed no significant difference in pain scores during splint removal and postoperative complications between the two groups except for mucosal crusting. CONCLUSION: Based on our findings, although there is no consensus on the optimal time for splint removal, earlier removal of splints can be considered a favorable option after septoplasty operations.


Subject(s)
Nasal Septum , Postoperative Complications , Splints , Humans , Female , Male , Adult , Nasal Septum/surgery , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Rhinoplasty/adverse effects , Rhinoplasty/methods , Time Factors , Middle Aged , Young Adult , Tampons, Surgical , Device Removal , Pain, Postoperative/etiology , Pain, Postoperative/epidemiology , Adolescent , Pain Measurement
7.
BMC Oral Health ; 24(1): 479, 2024 Apr 20.
Article in English | MEDLINE | ID: mdl-38643111

ABSTRACT

BACKGROUND: Temporomandibular disorder (TMD) is a grouping of heterogeneous disorders with multifactorial origins. Stabilization splints (SS) have demonstrated an acceptable treatment effect in TMD. The possible changes at the skeletal, dental, and soft tissue levels need to be addressed to evaluate the benefit/risk ratio of this therapeutic procedure. Accordingly, this study aimed to three­dimensionally evaluate skeletal, dentoalveolar and soft tissue changes after SS treatment for patients with TMD. METHODS: This retrospective study included 74 adult patients with myofascial and/or intra-articular disorders (25 males and 49 females), with an average age of 22.88 ± 4.8 years, who underwent SS treatment. Pre- and post-treatment Cone beam computed tomography were analysed using Invivo 6.0.3 software. The primary outcome was the vertical skeletal and dentoalveolar changes, while the secondary outcomes were the anteroposterior skeletal, dentoalveolar and soft tissue changes. Paired t-test and Wilcoxon rank sum test were used for statistical analyses. RESULTS: For the primary outcome; skeletally, there was a significant increase in mandibular plane inclination (difference: 0.82°±1.37), decrease facial height ratio (difference: 0.45%±1.07) and at the dentoalveolar level, the inclination of the functional (FOP-SN, FOP-FH) and bisecting (BOP-SN, BOP-FH) occlusal planes exhibited a significant increase too (difference: 0.38 ± 1.43°, 0.49 ± 1.62°, 0.44 ± 1.29° and 0.41 ± 1.17°, respectively) and also a decrease in the overbite (difference: -0.54 ± 0.83). For the secondary outcomes; there was a significant decrease in mandibular position (SNB) (difference: 1.60 ± 1.36°) and increase in the overjet (difference: 0.93 ± 1.04, p < 0.001) and a significant lower lip retrusion (difference: 0.33 ± 1.01 mm p < 0.01), was observed too. CONCLUSIONS: SS therapy resulted in significant vertical skeletal and dentoalveolar changes that were manifested mainly by facial height ratio, mandibular and occlusal plane changes, and to a lesser extent, significant anteroposterior skeletal, dentoalveolar, and soft tissue changes in the form of mandibular position, increased overjet and a more retrusive lower lip. These changes should be considered during patients' selection prior to initiating SS therapy.


Subject(s)
Malocclusion, Angle Class II , Overbite , Temporomandibular Joint Disorders , Male , Adult , Female , Humans , Adolescent , Young Adult , Maxilla , Retrospective Studies , Splints , Cephalometry/methods , Mandible/diagnostic imaging , Overbite/therapy , Malocclusion, Angle Class II/therapy , Temporomandibular Joint Disorders/diagnostic imaging , Temporomandibular Joint Disorders/therapy , Temporomandibular Joint
8.
Int J Prosthodont ; 37(7): 31-40, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38489218

ABSTRACT

PURPOSE: To investigate the insertion/pull-out performance of splints produced by hand casting, thermoforming, milling, and 3D printing. MATERIALS AND METHODS: A total of 120 identical mandibular splints (n = 8 specimens per group) were manufactured with hand casting, thermoforming, milling, and 3D printing. The splints were stored in water at 37°C for 10 days and then placed onto cobalt-chromium arches and fixed on one side. Forces were applied to the other side (centric, perpendicular 50 N, 1 Hz) at two different positions (teeth 46 and 44/45) to pull out, and the test was then reset. The number of pull-out cycles until failure was recorded. The fracture behavior of the splints was investigated and characterized as fracture in the loading position, fracture at the fixation, or combined fracture. Splints were pulled off until fracture as a control (v = 1 mm/minute). Finite element analysis was used to verify the results. Statistical analyses were conducted with one-way ANOVA, post hoc Bonferroni, Pearson correlation, and Kaplan-Meier log-rank tests (α = .05). RESULTS: The mean pull-off cycles varied from 7,839 (V-Print) to 1,600,000 (Optimill) at the tooth 46 position (FDI numbering system) and from 9,064 (Splint Comfort) to 797,750 (Optimill) at the 44/45 position. Log-rank test showed significantly (P < .001) different pull-out cycles between the systems (chi-square: 61,792 to 122,377). The thickness of the splints varied between 1.6 ± 0.2 mm (Splint Comfort) and 2.3 ± 0.1 mm (V-Print). Thickness and number of cycles were correlated (Pearson: 0.164; P = .074). The pull-off forces of the control varied significantly (P ≤ .040), ranging from 13.0 N (Keysplint) to 82.2 N (Optimill) at the tooth 46 position and from 25.2 N (Keysplint) to 139.0 N (Optimill) at the 44/45 position. CONCLUSIONS: The milled and cast splints survived more pull-off cycles than the printed or thermoformed splints. The pullout performance showed differences among the tested splint systems and indicated the influence of the material properties and processing.


Subject(s)
Splints , Tooth , Printing, Three-Dimensional , Materials Testing
9.
J Plast Reconstr Aesthet Surg ; 92: 179-185, 2024 May.
Article in English | MEDLINE | ID: mdl-38537560

ABSTRACT

The treatment of carpal boss is primarily conservative. Surgical treatment by performing a wedge excision of the bony protrusion, is possible. However, a common belief exists that carpal boss should not be operated because of the high recurrence rate. Additionally, little is known about the clinical outcomes of wedge excision and the preferred post-operative treatment. Patients with carpal boss and persisting pain who underwent wedge excision after conservative treatment were included. They received questionnaires before and three months after surgery. The primary outcomes were pain and hand function measured using patient-reported wrist evaluations (PRWE). Secondarily, recurrence, patient satisfaction and time until return to work were evaluated. These clinical outcomes were also compared between patients who received a plaster splint or a pressure dressing post-operatively. 76 patients were included. Three months after surgery, a significant improvement in PRWE was seen, for both pain and function. A re-operation rate for recurrent carpal boss of 13% was observed. After three months, 58% of patients were satisfied and 73% had returned to work. While no differences in clinical outcomes were found, patients were more satisfied after receiving a pressure dressing than a plaster splint post-operatively. The current study demonstrates encouraging early outcomes after wedge excision, and a low recurrence re-operation rate. Furthermore, a pressure dressing seems preferable post-operatively compared to a plaster splint.


Subject(s)
Patient Reported Outcome Measures , Patient Satisfaction , Recurrence , Humans , Female , Male , Adult , Middle Aged , Carpal Bones/surgery , Splints , Reoperation/statistics & numerical data , Treatment Outcome , Pain Measurement
10.
BMC Oral Health ; 24(1): 296, 2024 Mar 02.
Article in English | MEDLINE | ID: mdl-38431564

ABSTRACT

BACKGROUND: Overerupted maxillary molars is common in adults, which can lead to insufficient intermaxillary vertical space ,great difficulty in prosthetic reconstruction ,and cause occlusal interference in movements.To reconstruct occlusal function, it is necessary to prepare enough space for prostheses. The aim of the present study was to evaluate the effect of space-adjustment occlusal splint on overerupted maxillary molars by clinical and electromyographic signals analysis. METHODS: Eighteen patients with overerupted maxillary molars were selected to wear space-adjustment occlusal splint suppressing overerupted maxillary molars for three months. Satisfaction was assessed by 5-point Likert; intermaxillary vertical space and the teeth transportation distance were measured in models; clinical periodontal status were evaluated by periodontal probing depth (PPT) and bleeding index (BI); electromyographic recordings of the masseter and anterior temporal muscles were monitored by Cranio-Mandibular K7 Evaluation System. RESULTS: All the patients were satisfied with the treatment effect (Likert scale ≧ 4). The intermaxillary space in edentulous areas after treatment showed statistically significant increasing when compared with those before treatment. PPT and BI showed no significant difference. No statistically significant differences were found in electromyographic activity of anterior temporal muscles, while a reduction of muscle activity in masseter in the contralateral side were detected in post-treatment evaluations compared with pre-treatment at mandibular rest position. CONCLUSIONS: Space-adjustment occlusal splint is an efficient treatment option on overerupted maxillary molars by intruding the maxillary molar to obtain adequate intermaxillary space for prostheses.


Subject(s)
Molar , Splints , Adult , Humans , Molar/surgery , Masseter Muscle/physiology , Temporal Muscle/physiology , Occlusal Splints , Electromyography
11.
Braz Oral Res ; 38: e017, 2024.
Article in English | MEDLINE | ID: mdl-38477803

ABSTRACT

Occlusal stabilization splints are the most common treatment for controlling the deleterious effects of sleep bruxism. This study aimed to evaluate the effectiveness of a low-cost, mixed occlusal splint (MOS) compared to that of a rigid splint. A randomized clinical trial was performed on 43 adults of both sexes with possible sleep bruxism and satisfactory dental conditions. They were divided into rigid occlusal splint (ROS) (n = 23) and MOS (n = 20) groups. Masticatory muscle and temporomandibular joint (TMJ) pain intensity (visual analog scale), quality of life (WHOQOL-BREF), indentations in the oral mucosa, anxiety, and depression (HADS), number of days of splint use, and splint wear were evaluated. All variables were evaluated at baseline (T0), 6 months (T6), and 12 months (T12) after splint installation (T0), and splint wear was evaluated at T6 and T12. Student's t-test, Mann-Whitney U test, non-parametric Friedman's analysis of variance for paired samples and pairwise multiple comparisons, Pearson's chi-square test, two-proportion z-test, non-parametric McNemar's and Cochran's Q, and Wilcoxon tests were used (p < 0.05). In both groups, there was a decrease in TMJ pain and pain intensity over time and improvements in the quality of life scores. At T6, there was a higher rate of splint wear in the MOS group than in the ROS group (p = 0.023). The MOS showed a higher rate of wear than the rigid splint but had similar results for the other variables. Therefore, the use of a mixed splint appears to be effective in controlling the signs and symptoms of sleep bruxism.


Subject(s)
Occlusal Splints , Sleep Bruxism , Adult , Female , Male , Humans , Splints , Quality of Life , Reactive Oxygen Species
12.
Trials ; 25(1): 193, 2024 Mar 16.
Article in English | MEDLINE | ID: mdl-38493121

ABSTRACT

BACKGROUND: Without surgical repair, flexor tendon injuries do not heal and patients' ability to bend fingers and grip objects is impaired. However, flexor tendon repair surgery also requires optimal rehabilitation. There are currently three custom-made splints used in the rehabilitation of zone I/II flexor tendon repairs, each with different assumed harm/benefit profiles: the dorsal forearm and hand-based splint (long), the Manchester short splint (short), and the relative motion flexion splint (mini). There is, however, no robust evidence as to which splint, if any, is most clinical or cost effective. The Flexor Injury Rehabilitation Splint Trial (FIRST) was designed to address this evidence gap. METHODS: FIRST is a parallel group, superiority, analyst-blind, multi-centre, individual participant-randomised controlled trial. Participants will be assigned 1:1:1 to receive either the long, short, or mini splint. We aim to recruit 429 participants undergoing rehabilitation following zone I/II flexor tendon repair surgery. Potential participants will initially be identified prior to surgery, in NHS hand clinics across the UK, and consented and randomised at their splint fitting appointment post-surgery. The primary outcome will be the mean post-randomisation score on the patient-reported wrist and hand evaluation measure (PRWHE), assessed at 6, 12, 26, and 52 weeks post randomisation. Secondary outcome measures include blinded grip strength and active range of movement (AROM) assessments, adverse events, adherence to the splinting protocol (measured via temperature sensors inserted into the splints), quality of life assessment, and further patient-reported outcomes. An economic evaluation will assess the cost-effectiveness of each splint, and a qualitative sub-study will evaluate participants' preferences for, and experiences of wearing, the splints. Furthermore, a mediation analysis will determine the relationship between patient preferences, splint adherence, and splint effectiveness. DISCUSSION: FIRST will compare the three splints with respect to clinical efficacy, complications, quality of life and cost-effectiveness. FIRST is a pragmatic trial which will recruit from 26 NHS sites to allow findings to be generalisable to current clinical practice in the UK. It will also provide significant insights into patient experiences of splint wear and how adherence to splinting may impact outcomes. TRIAL REGISTRATION: ISRCTN: 10236011.


Subject(s)
Joint Diseases , Tendon Injuries , Humans , Multicenter Studies as Topic , Pragmatic Clinical Trials as Topic , Quality of Life , Splints , Tendon Injuries/diagnosis , Tendon Injuries/surgery , Tendons/surgery , Treatment Outcome , Randomized Controlled Trials as Topic
13.
PLoS One ; 19(3): e0299816, 2024.
Article in English | MEDLINE | ID: mdl-38527030

ABSTRACT

This study evaluated the biomechanical performance of narrow-diameter implant (NDI) treatment in atrophic maxillary posterior teeth in aging patients by finite element analysis. The upper left posterior bone segment with first and second premolar teeth missing obtained from a patient's cone beam computed tomography data was simulated with cortical bone thicknesses of 0.5 and 1.0 mm. Three model groups were analyzed. The Regimen group had NDIs of 3.3 × 10 mm in length with non-splinted crowns. Experimental-1 group had NDIs of 3.0 × 10 mm in length with non-splinted crowns and Experimental-2 group had NDIs of 3.0 × 10 mm in length with splinted crowns. The applied load was 56.9 N in three directions: axial (along the implant axis), oblique at 30° (30° to the bucco-palatal plane compared to the vertical axis of the tooth), and lateral load at 90° (90° in the bucco-palatal plane compared to the vertical axis of the tooth). The results of the von Mises stress on the implant fixture, the elastic strain, and principal value of stress on the crestal marginal bone were analyzed. The axial load direction was comparable in the von Mises stress values in all groups, which indicated it was not necessary to use splinted crowns. The elastic strain values in the axial and oblique directions were within the limits of Frost's mechanostat theory. The principal value of stress in all groups were under the threshold of the compressive stress and tensile strength of cortical bone. In the oblique and lateral directions, the splinted crown showed better results for both the von Mises stress, elastic strain, and principal value of stress than the non-splinted crown. In conclusion, category 2 NDIs can be used in the upper premolar region of aging patients in the case of insufficient bone for category 3 NDI restorations.


Subject(s)
Dental Implants , Maxilla , Humans , Finite Element Analysis , Bicuspid/diagnostic imaging , Bicuspid/surgery , Maxilla/diagnostic imaging , Maxilla/surgery , Crowns , Splints , Dental Stress Analysis , Stress, Mechanical , Biomechanical Phenomena
14.
BMC Oral Health ; 24(1): 363, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38515064

ABSTRACT

BACKGROUND: Temporomandibular disorders (TMDs) encompass pain and dysfunction in the jaw, muscles, and adjacent structures. This study aimed to explore the quantitative (condylar position, morphology) and qualitative (bone mineral density (BMD)) therapeutic outcomes following a stabilization splint (S.S.) therapy in adult patients diagnosed with TMD (Arthralgia) with/without lateral mandibular asymmetry (MA) using cone beam computed tomography (CBCT). METHODS: In this retrospective clinical study, 60 adult TMD patients who received S.S. therapy were enrolled and allocated into the TMD group (TMDG) and TMD with MA group (TMD + MAG). The diagnosis was made according to the Diagnostic Criteria for TMD (DC/TMD) AXIS I. MA was measured from the mid-sagittal plane to the Menton point. CBCT was used to scan the temporomandibular joints pre- (T0) and post- (T1)-treatment for three-dimensional analysis. Intra- and intergroup statistical comparisons were performed using the Wilcoxon signed ranks and the Kruskal‒Wallis test. RESULTS: For quantitative comparisons, there was a statistically significant difference between T0 and T1 in the joint spaces of TMD + MAG (anterior, superior, posterior, and coronal lateral on the deviated side as well as in the superior, coronal medial joint space of the contralateral side). Morphologically, the deviated side had a narrower condylar width, reduced condylar height, and a steeper eminence angle. In contrast, the contralateral side tended to have a greater condylar length. For qualitative measurements, BMD also showed statistical significance between T0 and T1 in the majority of the condyle slopes (AS, SS, PS, and LS on the deviated side and in AS and MS on the contralateral side) of TMD + MAG. Additionally, only the AS and PS showed significance in TMDG. CONCLUSION: Multiple joint space widening (AJS and CMS) and narrowing (SJS, PJS, and CLS) could characterize the deviated side in TMD + MA. Factors like narrower condylar width, reduced condylar height, and steeper eminence angle on the deviated side can worsen TMD + MA. Proper alignment of the condyle-disc position is essential for optimal function and load distribution, potentially affecting bone mineral density (BMD). MA plays a prominent role in disturbing bone densities. S.S. therapy shows more evident outcomes in TMD + MAG (on the deviated side compared to the contralateral side) than the TMDG.


Subject(s)
Mandibular Condyle , Temporomandibular Joint Disorders , Adult , Humans , Mandibular Condyle/diagnostic imaging , Splints , Retrospective Studies , Temporomandibular Joint/diagnostic imaging , Temporomandibular Joint Disorders/diagnostic imaging , Temporomandibular Joint Disorders/therapy , Cone-Beam Computed Tomography
15.
J Oral Implantol ; 50(1): 50-64, 2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38329841

ABSTRACT

The choice of a splinted or nonsplinted implant-supported prosthesis should be based on solid scientific evidence that considers the conditions and needs of each patient. This review elaborates on the factors that directly influence clinical decisions between splinted or nonsplinted dental implants. Digital and manual searches of the published literature were conducted to identify studies that examined splinted prostheses (SPs) and nonsplinted prostheses (NSPs). The search terms used, alone or in combination, were "splinting prosthesis," "nonsplinting prosthesis," "prosthetic design," "stress distribution in dental implant," "implant loading," "implant occlusion," and "crestal bone resorption." Ninety-four studies were selected to compare and address the details emphasized in this study. Thirty-four reported articles were not directly related to restoration design but were reviewed to better understand the influence of mechanical risk factors, finite element analysis limits, and criteria for implant survival and treatment success. There are advantages and disadvantages of splinting implants together. NSPs are the ideal choice because they resemble natural teeth. Splinting a restored implant will cause the implant to appear as part of one unit and is indicated in more compromised situations, unfavorable conditions, or when pontic spaces and cantilevers are needed in implant prostheses.


Subject(s)
Dental Implants , Humans , Dental Prosthesis Design , Dental Prosthesis, Implant-Supported , Treatment Outcome , Splints
16.
J Mech Behav Biomed Mater ; 152: 106458, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38364445

ABSTRACT

OBJECTIVES: To investigate the influence of material and printing orientation on wear resistance and flexural properties of one low force SLA- and two DLP-printed splint materials and to compare these 3D-printed splints to a subtractively manufactured splint material. METHODS: Two DLP-printed (V-Print splint, LuxaPrint Ortho Plus) and one low force SLA-printed (Dental LT Clear) material, where specimens were printed in three printing orientations (0°, 45°, 90°), were investigated. In addition, one milled splint material (Zirlux Splint Transparent) was examined. A total of 160 specimens were produced for both test series. The two-body wear test was performed in a chewing simulator (80'000 cycles at 50 N with 5-55 °C thermocycling). Steatite balls were used as antagonists. The wear pattern was analyzed with a 3D digital microscope in terms of maximum vertical intrusion depth (mm) and total volume loss (mm³). The flexural properties were investigated by three-point bending in accordance with ISO 20795-1: 2013 (denture base polymers). The flexural strength (MPa) and the flexural modulus (MPa) were measured. Two-way ANOVA was performed to investigate the effects of the two independent variables material and printing orientation for the three 3D-printed materials. The comparison of the printing orientations within one material was carried out with one-way ANOVA with post-hoc Tukey tests. RESULTS: Two-way ANOVA revealed that wear and flexural properties are highly dependent on the 3D-printed material (p < 0.001). Across groups, a significant effect was observed for wear depth (p = 0.031) and wear volume (p = 0.044) with regard to printing orientation but this was not found for flexural strength (p = 0.080) and flexural modulus (p = 0.136). One-way ANOVA showed that both DLP-printed groups showed no significant differences within the printing orientations in terms of wear and flexural properties. Dental LT Clear showed that 90° oriented specimens had higher flexural strength than 0° oriented ones (p < 0.001) and 45° oriented specimens also showed higher values than 0° ones (p = 0.038). No significant differences were observed within the printing orientations for flexural modulus and wear behaviour within this group. T-tests showed that the milled splints exhibited statistically higher wear resistance and flexural properties compared to all three 3D-printed splint materials (p < 0.001) and that highly significant differences were found between the 3D-printed splint materials for both test series. CONCLUSION: Within the limitations of this in vitro study, it can be stated that wear behaviour and flexural properties are highly dependent on the 3D-printed material itself. Currently, milled splints exhibit higher wear resistance and flexural properties compared to 3D-printed splint materials. The printing orientation has a minor influence on the properties investigated. Nevertheless, two-way ANOVA also showed a significant influence of printing orientation in the wear test across groups and one-way ANOVA detected significant effects for SLA material in terms of flexural strength, with printing in 90° showing the highest flexural strength. Therefore, anisotropy was found in SLA material, but it can be limited with the employed printing parameters. Both DLP-printed materials showed no significant difference within the printing orientation.


Subject(s)
Flexural Strength , Gastropoda , Animals , Splints , Analysis of Variance , Anisotropy , Printing, Three-Dimensional
17.
Bone Joint J ; 106-B(3 Supple A): 130-136, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38423088

ABSTRACT

Aims: Despite higher rates of revision after total hip arthroplasty (THA) being reported for uncemented stems in patients aged > 75 years, they are frequently used in this age group. Increased mortality after cemented fixation is often used as a justification, but recent data do not confirm this association. The aim of this study was to investigate the influence of the design of the stem and the type of fixation on the rate of revision and immediate postoperative mortality, focusing on the age and sex of the patients. Methods: A total of 333,144 patients with primary osteoarthritis (OA) of the hip who underwent elective THA between November 2012 and September 2022, using uncemented acetabular components without reconstruction shells, from the German arthroplasty registry were included in the study. The revision rates three years postoperatively for four types of stem (uncemented, uncemented with collar, uncemented short, and cemented) were compared within four age groups: < 60 years (Young), between 61 and 70 years (Mid-I), between 71 and 80 years (Mid-II), and aged > 80 years (Old). A noninferiority analysis was performed on the most frequently used designs of stem. Results: The design of the stem was found to have no significant influence on the rate of revision for either sex in the Young group. Uncemented collared stems had a significantly lower rate of revision compared with the other types of stem for females in the Mid-I group. There was a significantly higher rate of revision for uncemented stems in females in the Mid-II group compared with all other types of stem, while in males the rate for uncemented stems was only significantly higher than the rate for cemented stems. Cemented stems had a significantly lower revision rate compared with uncemented and short stems for both sexes in the Old cohort, as did females with collared stems. The rate of immediate postoperative mortality was similar for all types of stem in the Old age group, as were the American Society of Anesthesiologists grades. Conclusion: In patients aged > 80 years, uncemented and short stems had significantly higher revision rates compared with cemented and collared stems, especially in females. The design of the stem and type of fixation have to be analyzed in more detail than only considering cemented and uncemented fixation, in order to further improve the success of THA.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Female , Male , Humans , Middle Aged , Acetabulum , Postoperative Period , Registries , Splints , Reoperation , Prosthesis Failure , Prosthesis Design
18.
BMC Musculoskelet Disord ; 25(1): 163, 2024 Feb 21.
Article in English | MEDLINE | ID: mdl-38383364

ABSTRACT

BACKGROUND: There is a controversy on the effectiveness of post-operating splinting in patients with carpal tunnel release (CTR) surgery. This study aimed to systematically evaluate various outcomes regarding the effectiveness of post-operating splinting in CTR surgery. METHODS: Multiple databases, including PubMed, EMBASE, CINAHL, Web of Science, and Cochrane, were searched for terms related to carpal tunnel syndrome. A total of eight studies involving 596 patients were included in this meta-analysis. The quality of studies was evaluated, and their risk of bias was calculated using the methodological index for non-randomized studies (MINORS) and Cochrane's collaboration tool for assessing the risk of bias in randomized controlled trials. Data including the visual analogue scale (VAS), pinch strength, grip strength, two-point discrimination, symptom severity score (SSS), and functional status scale (FSS) were extracted. RESULTS: Our analysis showed no significant differences between the splinted and non-splinted groups based on the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. The calculated values of the standardized mean difference (SMD) or the weighted mean difference (WMD) and a 95% confidence interval (CI) for different variables were as follows: VAS [SMD = 0.004, 95% CI (-0.214, 0.222)], pinch strength [WMD = 1.061, 95% CI (-0.559, 2.681)], grip strength [SMD = 0.178, 95% CI (-0.014, 0.369)], SSS [WMD = 0.026, 95% CI (- 0.191, 0.242)], FSS [SMD = 0.089, 95% CI (-0.092, 0.269)], and the two-point discrimination [SMD = 0.557, 95% CI (-0.140, 1.253)]. CONCLUSIONS: Our findings revealed no statistically significant differences between the splinted and non-splinted groups in terms of the VAS, SSS, FSS, grip strength, pinch strength, and two-point discrimination. These results indicate that there is no substantial evidence supporting a significant advantage of post-operative splinting after CTR.


Subject(s)
Carpal Tunnel Syndrome , Humans , Carpal Tunnel Syndrome/diagnosis , Carpal Tunnel Syndrome/surgery , Hand Strength , Pinch Strength , Splints , Pain Measurement
19.
Eur J Orthod ; 46(2)2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38376495

ABSTRACT

BACKGROUND: Juvenile idiopathic arthritis (JIA) frequently affects the temporomandibular joint (TMJ), which can alter mandibular growth and development and result in dentofacial deformities. OBJECTIVE: To assess the outcomes of orthopedic treatment with distraction splint (DS) in patients with JIA-related dentofacial deformity. METHODS: The retrospective study involved 30 patients with JIA and unilateral TMJ involvement, another study group of 20 patients with JIA and bilateral TMJ involvement, and a control group of 18 non-JIA orthodontic patients with Class II and III malocclusions. The inclusion criteria were DS treatment and cone-beam computed tomography (CBCT) scans before (T0) and 2 years after treatment (T1). Dentofacial morphology and deformity were evaluated based on a validated three-dimensional CBCT-based morphometric analysis. Intergroup differences in outcome measures were compared at T0 and T1, and intragroup changes between T0 and T1 were assessed using the Kruskal-Wallis test. RESULTS: Initial evaluations at T0 revealed significant differences between the unilateral and bilateral JIA groups and the control group for three out of eight dentofacial deformity variables: inter-side difference in total posterior mandibular height, mandibular axial angle, and posterior/anterior face height (ratio). At follow-up (T1), significant inter-group differences were only observed in total posterior mandibular height indicating that intergroup differences were less pronounced after splint treatment. Assessing inter-group changes between T0 and T1 showed that all parameters remained constant except posterior/anterior face height ratio, which significantly decreased between T0 and T1. CONCLUSIONS: The findings demonstrate the potential of DS treatment for patients with JIA and unilateral or bilateral TMJ involvement to generally support normal dentofacial growth or at least limit further deterioration of dentofacial deformities.


Subject(s)
Arthritis, Juvenile , Dentofacial Deformities , Humans , Arthritis, Juvenile/complications , Arthritis, Juvenile/diagnostic imaging , Arthritis, Juvenile/therapy , Dentofacial Deformities/diagnostic imaging , Dentofacial Deformities/therapy , Retrospective Studies , Splints , Mandible/diagnostic imaging
20.
Clin Oral Investig ; 28(2): 141, 2024 Feb 10.
Article in English | MEDLINE | ID: mdl-38340152

ABSTRACT

OBJECTIVES: Successful orthognathic surgery requires accurate transfer of the intraoperative surgical plan. This study aimed to (1) evaluate the surgical error of a novel intermediate splint in positioning the maxilla during maxilla-first orthognathic surgery and (2) determine factors influencing surgical error. MATERIALS AND METHODS: This prospective study examined 83 patients who consecutively underwent Le Fort I osteotomy for correction of skeletal class III deformity using a novel intermediate splint and a bilateral sagittal split osteotomy. Surgical error was the outcome variable, measured as the difference in postoperative translational and rotational maxillary position from the virtual plan. Measures included asymmetry, need and amount for mandibular opening during fabrication of intermediate splints, and planned and achieved skeletal movement. RESULTS: Mean errors in translation for vertical, sagittal, and transversal dimensions were 1.0 ± 0.7 mm, 1.0 ± 0.6 mm, and 0.7 ± 0.6 mm, respectively; degrees in rotation for yaw, roll, and pitch were 0.8 ± 0.6, 0.6 ± 0.4, and 1.6 ± 1.1, respectively. The transverse error was smaller than sagittal and vertical errors; error for pitch was larger than roll and yaw (both p < 0.001). Error for sagittal, transverse, and roll positioning was affected by the achieved skeletal movement (roll, p < 0.05; pitch and yaw, p < 0.001). Surgical error of pitch positioning was affected by planned and achieved skeletal movement (both p < 0.001). CONCLUSIONS: Using the novel intermediate splint when performing Le Fort I osteotomy allowed for accurate positioning of the maxilla. CLINICAL RELEVANCE: The novel intermediate splint for maxillary positioning can be reliably used in clinical routines.


Subject(s)
Orthognathic Surgery , Orthognathic Surgical Procedures , Humans , Maxilla/surgery , Splints , Prospective Studies , Osteotomy, Le Fort/methods , Orthognathic Surgical Procedures/methods , Imaging, Three-Dimensional/methods , Cephalometry
SELECTION OF CITATIONS
SEARCH DETAIL
...