Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 513
Filter
1.
Colorectal Dis ; 26(4): 754-759, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38443753

ABSTRACT

AIM: Creation of an overlapped anastomosis using handsewn sutures for common enterotomy is very popular in robotic right colectomy (RRC) with intracorpareal anastomosis (IA). The aim of this study is to present a simple method for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in RRC with IA. METHOD: The distal ileum and proximal colon were put in overlapping positions. Enterotomies were created 2 cm proximal to the ileal stump and 8 cm distal to the colonic stump on the antimesenteric side. Subsequently, a 60 mm linear stapler with a reinforced bioabsorbable material was inserted into each lumen and fired. Finally, the bowel was elevated while holding the bioabsorbable material, and the common enterotomy was grasped with the robotic instrument in the middle and closed using a linear stapler with a reinforced bioabsorbable material. RESULTS: This technique was applied to 10 patients with tumours of the caecum, ascending colon, or transverse colon. The median operating time, anastomosis construction time, blood loss, and postoperative stay were 281 min (range 228-459 min), 12 min (range 11-17 min), 10 mL (range 0-110 mL), and 10 days (range 8-15 days), respectively. No adverse intraoperative events were observed. Postoperatively, one patient developed chylous ascites, but there were no other complications. CONCLUSION: The simple technique for constructing a sutureless overlapped anastomosis using a 60 mm linear stapler with a reinforced bioabsorbable material in robotic right colectomy with intracorporeal anastomosis appears to be safe and feasible.


Subject(s)
Absorbable Implants , Anastomosis, Surgical , Colectomy , Colonic Neoplasms , Ileum , Robotic Surgical Procedures , Surgical Staplers , Colectomy/methods , Colectomy/instrumentation , Humans , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Robotic Surgical Procedures/methods , Robotic Surgical Procedures/instrumentation , Male , Female , Middle Aged , Aged , Colonic Neoplasms/surgery , Ileum/surgery , Sutureless Surgical Procedures/methods , Sutureless Surgical Procedures/instrumentation , Operative Time , Colon/surgery , Treatment Outcome , Surgical Stapling/methods , Surgical Stapling/instrumentation , Adult , Length of Stay
4.
Colorectal Dis ; 26(4): 766-771, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38302860

ABSTRACT

AIM: Natural orifice specimen extraction (NOSE) in left-sided colorectal surgery requires application of the circular stapler anvil to the proximal bowel without exteriorization through an additional abdominal incision. We describe an intracorporeal method to secure the stapler anvil, termed the intracorporeal antimesenteric ancillary trocar (IAAT) technique. METHOD: The ancillary trocar is attached to the stapler anvil before introduction into the abdominal cavity through the anal or vaginal orifice. The colon is incised before the trocar spike is brought out through the antimesenteric surface 3-4 cm within the cut edge. A linear stapler is used to seal the bowel end. The ancillary trocar is detached and retrieved via the NOSE conduit. Following the NOSE procedure, a side-to-end colorectal anastomosis is performed with the transanal circular stapler. RESULTS: Ten consecutive patients underwent elective left-sided colorectal resection with IAAT for NOSE (seven transanal, three transvaginal) from January to June 2023. Median age and body mass index were 66 (range 47-74) years and 24.3 (range 17.9-30.8) kg/m2 respectively. Two (20%) patients underwent sigmoid colectomy for sigmoid volvulus while eight (80%) underwent anterior resection for colorectal cancer. Median operating time, operative blood loss and postoperative length of hospital stay were 170 (range 140-240) min, 20 (range 10-40) mL and 1 (range 1-3) day respectively. There were no postoperative complications, readmissions or reoperations. Median follow-up duration was 3 (range 1-6) months. CONCLUSION: The IAAT double-stapling side-to-end anastomotic technique is safe and feasible for patients undergoing left-sided colorectal resection with NOSE, resulting in good outcomes.


Subject(s)
Anastomosis, Surgical , Colectomy , Natural Orifice Endoscopic Surgery , Humans , Female , Middle Aged , Anastomosis, Surgical/methods , Anastomosis, Surgical/instrumentation , Aged , Male , Natural Orifice Endoscopic Surgery/methods , Natural Orifice Endoscopic Surgery/instrumentation , Colectomy/methods , Colectomy/instrumentation , Colon/surgery , Surgical Instruments , Vagina/surgery , Surgical Staplers , Surgical Stapling/methods , Surgical Stapling/instrumentation , Rectum/surgery , Operative Time
5.
Dis Colon Rectum ; 65(2): 246-253, 2022 02 01.
Article in English | MEDLINE | ID: mdl-34657080

ABSTRACT

BACKGROUND: The International Transanal Total Mesorectal Excision Registry group showed that transanal total mesorectal excision included clinical issues regarding anastomosis-related complications. OBJECTIVE: This study evaluated anastomotic complications in patients whose anastomoses were created with the stapler plus reinforced sutures procedure after transanal total mesorectal excision for low rectal cancer. DESIGN: This was a retrospective single-center study. SETTING: The study was conducted at the National Cancer Center Hospital East, Japan. PATIENTS: Between June 2016 and December 2019, 150 patients underwent transanal total mesorectal excision for low rectal cancer. Stapled anastomosis was performed for 55 patients, and coloanal handsewn anastomosis was performed for 95 patients. Blood perfusion of the colon was routinely evaluated with intraoperative indocyanine green fluorescence angiography. All patients who underwent stapled anastomosis received additional handsewn sutures on all rounds of the stapled line. Patients who underwent intersphincteric resection were excluded. MAIN OUTCOME MEASURES: The anastomosis-related complications were compared between the groups. RESULTS: Early anastomotic leakage was found in one (1.8%) and eight (8.4%) patients in the stapled group and handsewn group. Overall anastomosis-related complications, pelvic abscess, and anastomotic stenosis were significantly less frequent in the stapled group (p < 0.001, p < 0.048, and p < 0.032). Incomplete donuts after the stapled anastomosis were observed in 9 patients (16.4%); however, we reinforced all around the stapled line in these patients, and this reduced the subsequent occurrence of anastomotic leakage. LIMITATIONS: First, this was a retrospective single-center study that was not randomized or controlled. Second, there were chronological differences regarding the anastomotic method between the two groups. Third, our study included a relatively small number of patients who received preoperative chemoradiotherapy. CONCLUSIONS: Stapled anastomosis with reinforced handsewn sutures resulted in fewer anastomosis-related complications than did coloanal handsewn anastomosis after transanal total mesorectal excision for low rectal cancer; thus, the former may be superior and should be the preferred method, when technically possible. See Video Abstract at http://links.lww.com/DCR/B749.COMPLICACIONES RELACIONADAS CON LAS ANASTOMOSIS ENGRAMPADAS Y REFORZADAS CON SUTURAS EN LA EXCISIÓN TOTAL DEL MESORRECTO POR VÍA TRANSANAL EN CASOS DE CÁNCER DE RECTO BAJO: ESTUDIO RETROSPECTIVO UNICÉNTRICO. ANTECEDENTES: El grupo del Registro Internacional de Excisión Total del Mesorrecto por vía Transanal mostró que la excisión total mesorrectal transanal incluía problemas clínicos relacionados a las complicaciones involucradas con la anastomosis. OBJETIVO: Se evaluaron las complicaciones anastomóticas en pacientes cuyas anastomosis se realizaron con engrampadora reforzada de suturas después de la excisión total de l mesorrecto por vía transanal en casos de cáncer de recto bajo. DISEO: Estudio retrospectivo unicéntrico. AJUSTE: El Hospital del Centro Nacional del Cáncer del Este, Japón. PACIENTES: Entre junio de 2016 y diciembre de 2019, 150 pacientes se sometieron a excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo. Se realizó anastomosis con engrampadora en 55 y anastomosis coloanal suturada a mano en 95 pacientes. La perfusión tisular sanguínea del colon operado se evaluó de forma rutinaria con angiografía de fluorescencia con verde de indocianina intraoperatoria. Todos los pacientes que se sometieron a anastomosis con grapas recibieron suturas realizadas a mano adicionales sobre la totalidad de la línea de grapas. Se excluyeron los pacientes sometidos a resección interesfintérica. PRINCIPALES MEDIDAS DE RESULTADO: Las complicaciones relacionadas con la anastomosis se compararon entre los grupos. RESULTADOS: Se encontró fuga anastomótica temprana en 1 (1.8%) y 8 (8.4%) pacientes en el grupo de engrampado y en el grupo suturado a mano, respectivamente. En general, las complicaciones relacionadas con la anastomosis, el absceso pélvico y la estenosis anastomótica fueron significativamente menos frecuentes en el grupo con grapas (p < 0.001, p < 0.048, p < 0.032, respectivamente). Se observaron donas incompletas después de la anastomosis grapada en 9 pacientes (16,4%); sin embargo, reforzamos todo alrededor de la línea de grapas en estos pacientes, y esto redujo la aparición posterior de fugas anastomóticas. LIMITACIONES: Inicialmente, este fue un estudio retrospectivo de un solo centro que no fue aleatorizado ni controlado. En segundo lugar, hubo diferencias cronológicas con respecto al método anastomótico entre los dos grupos. En tercer lugar, nuestro estudio incluyó un número relativamente pequeño de pacientes que recibieron quimiorradioterapia preoperatoria. CONCLUSIONES: La anastomosis engrapada reforzada con suturas realizadas a mano dio como resultado menos complicaciones relacionadas con la anastomosis que la anastomosis coloanal suturada a mano después de la excisión total del mesorrecto por vía transanal en casos de cáncer de recto bajo; por tanto, el primero puede ser superior y debería ser el método preferido, cuando sea técnicamente posible. Consulte Video Resumen en http://links.lww.com/DCR/B749. (Traducción-Dr. Xavier Delgadillo).


Subject(s)
Anastomosis, Surgical/adverse effects , Postoperative Complications/epidemiology , Proctectomy/adverse effects , Rectal Neoplasms/surgery , Surgical Stapling/adverse effects , Sutures/adverse effects , Adult , Aged , Aged, 80 and over , Anastomosis, Surgical/instrumentation , Female , Humans , Japan , Male , Middle Aged , Rectal Neoplasms/pathology , Retrospective Studies , Surgical Stapling/instrumentation
6.
Surg Today ; 52(2): 260-267, 2022 Feb.
Article in English | MEDLINE | ID: mdl-34322726

ABSTRACT

PURPOSE: Postoperative pancreatic fistula (POPF) remains the most clinically relevant complication of laparoscopic distal pancreatectomy (LDP). The present study evaluated the efficacy of the "slow firing method" using a reinforced triple-row stapler (Covidien, Tokyo, Japan) during LDP. METHODS: This retrospective single-center study included 73 consecutive patients who underwent LDP using the slow firing method. A black cartridge was used in all patients. The primary endpoint was the rate of clinically relevant POPF (CR-POPF) after LDP. Secondary endpoints included perioperative outcomes and factors associated with CR-POPF as well as the correlation between the transection time and thickness of the pancreas. RESULTS: Four patients (5.5%) developed CR-POPF (grade B). Overall morbidity rates, defined as grade ≥ II and ≥ III according to the Clavien-Dindo classification, were 21 and 11%, respectively. The median postoperative hospital stay was 10 days. Preoperative diabetes (13.6 vs. 0.2%, P = 0.044) and thickness of the pancreas ≥ 15 mm (13.8% vs. 0%, P = 0.006) were identified as independent risk factors for CR-POPF. The median transection time was 16 (8-29) min. CONCLUSION: The slow firing method using a reinforced triple-row stapler for pancreatic transection is simple, safe, and effective for preventing CR-POPF after LDP.


Subject(s)
Laparoscopy/methods , Pancreatectomy/methods , Pancreatic Fistula/prevention & control , Postoperative Complications/prevention & control , Surgical Staplers , Surgical Stapling/methods , Adolescent , Adult , Aged , Aged, 80 and over , Female , Glycosides , Humans , Male , Middle Aged , Operative Time , Pregnanes , Risk Factors , Safety , Surgical Stapling/instrumentation , Treatment Outcome , Young Adult
7.
Anticancer Res ; 41(11): 5821-5825, 2021 Nov.
Article in English | MEDLINE | ID: mdl-34732457

ABSTRACT

AIM: Anastomotic leakage (AL) in left-sided colorectal cancer is a serious complication, with an incidence rate of 6-18%. We developed a novel predictive model for AL in colorectal surgery with double-stapling technique (DST) anastomosis using auto-artificial intelligence (AI). PATIENTS AND METHODS: A total of 256 patients who underwent curative surgery for left-sided colorectal cancer between 2017 and 2021 were included. In addition to conventional clinicopathological factors, we included the type of circular stapler using DST, conventional double-row circular stapler (DCS) or EEA™ circular stapler with Tri-Staple™ technology, 28 mm Medium/Thick (Covidien, New Haven, CT, USA) which had triple-row circular stapler (TCS) as a covariate. Auto-AI software Prediction One (Sony Network Communications Inc.) was used to predict AL with 5-fold cross validation. Predictive accuracy was assessed using the area under the receiver operating characteristic curve. Prediction One also evaluated the 'importance of variables' (IOV) using a method based on permutation feature importance. RESULTS: The area under the curve of the AI model was 0.766. The type of circular stapler used was the most influential factor contributing to AL (IOV=0.551). CONCLUSION: This auto-AI predictive model demonstrated an improvement in accuracy compared to the conventional model. It was suggested that use of a TCS may contribute to a reduction in the AL rate.


Subject(s)
Anastomotic Leak/etiology , Colectomy/adverse effects , Colorectal Neoplasms/surgery , Decision Support Techniques , Machine Learning , Surgical Stapling/adverse effects , Aged , Anastomotic Leak/diagnosis , Databases, Factual , Female , Humans , Male , Predictive Value of Tests , Retrospective Studies , Risk Assessment , Risk Factors , Surgical Staplers , Surgical Stapling/instrumentation , Time Factors , Treatment Outcome
8.
PLoS One ; 16(6): e0253548, 2021.
Article in English | MEDLINE | ID: mdl-34166443

ABSTRACT

INTRODUCTION: Robotic-assisted techniques are common across many surgical subspecialties. While robotic stapling offers increased surgeon control, there is limited information on surgical complications related to robotic stapler use. METHODS: We reviewed the FDA's MAUDE database for adverse events related to robotic stapler use. RESULTS: Upon review of the FDA database, the most frequently reported robotic stapler complications were malfunction, failure to form staple line, device fragmentation, and misfire. 31 Clavien-Dindo grade II or higher complications were attributed to stapler use since 2014. CONCLUSIONS: Further research on prevalence of robotic stapler use is needed to quantity the associated complication rate.


Subject(s)
Databases, Factual , Equipment Failure , Robotic Surgical Procedures , Surgical Staplers/adverse effects , Humans , Robotic Surgical Procedures/adverse effects , Robotic Surgical Procedures/instrumentation , Surgical Stapling/adverse effects , Surgical Stapling/instrumentation , United States , United States Food and Drug Administration
9.
Br J Surg ; 108(3): 265-270, 2021 04 05.
Article in English | MEDLINE | ID: mdl-33793753

ABSTRACT

BACKGROUND: Postoperative pancreatic fistula is the leading cause of morbidity after distal pancreatectomy. Strategies investigated to reduce the incidence have been disappointing. Recent data showed a reduction in postoperative pancreatic fistula with the use of synthetic mesh reinforcement of the staple line. METHODS: An RCT was conducted between May 2014 and February 2016 at four tertiary referral centres in Sweden. Patients scheduled for distal pancreatectomy were eligible. Enrolled patients were randomized during surgery to stapler transection with biological reinforcement or standard stapler transection. Patients were blinded to the allocation. The primary endpoint was the development of any postoperative pancreatic fistula. Secondary endpoints included morbidity, mortality, and duration of hospital stay. RESULTS: Some 107 patients were randomized and 106 included in an intention-to-treat analysis (56 in reinforced stapling group, 50 in standard stapling group). No difference was demonstrated in terms of clinically relevant fistulas (grade B and C): 6 of 56 (11 per cent) with reinforced stapling versus 8 of 50 (16 per cent) with standard stapling (P = 0.332). There was no difference between groups in overall postoperative complications: 45 (80 per cent) and 39 (78 per cent) in reinforced and standard stapling groups respectively (P = 0.765). Duration of hospital stay was comparable: median 8 (range 2-35) and 9 (2-114) days respectively (P = 0.541). CONCLUSION: Biodegradable stapler reinforcement at the transection line of the pancreas did not reduce postoperative pancreatic fistula compared with regular stapler transection in distal pancreatectomy. Registration number: NCT02149446 (http://www.clinicaltrials.gov).


Subject(s)
Absorbable Implants , Pancreatectomy/adverse effects , Pancreatic Fistula/prevention & control , Surgical Stapling/instrumentation , Surgical Stapling/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Length of Stay , Male , Middle Aged , Pancreatic Fistula/etiology , Postoperative Complications/prevention & control , Prospective Studies , Surgical Mesh
10.
Zhonghua Wai Ke Za Zhi ; 59(3): 196-202, 2021 Mar 01.
Article in Chinese | MEDLINE | ID: mdl-33685053

ABSTRACT

Objective: To evaluate the safety and efficacy of stent-assisted coil embolization in patients with recurrent intracranial bifurcation aneurysms,after initial simple coiling or microsurgical clipping. Methods: Clinical data of 20 patients with recurrent intracranial bifurcation aneurysms who initially underwent simple coiling or surgical clipping and subsequently re-treated by stent-assisted coiling embolization at the Radiology Intervention Department of Huashan Hospital between March 2009 and November 2019 were collected and analyzed retrospectively.There were 9 males and 11 females,with a median age of 55.5 years (range:33 to 71 years),including 17 aneurysms initially treated with simple coiling and 3 treated with surgical clipping.All cases were re-treated with stent-assisted coiling,15 using a single stent and 5 employing two stents in a Y-configuration.Peri-and post-operative complications and outcomes were evaluated.Mann-Whitney U tests were performed to compare the follow-up duration between initial treatment and re-treatment.Student's t tests were used to compare the parent artery angles before re-treatment, after re-treatment and at the last follow-up. The parent artery angle was defined using the proximal main trunk and the stented branch. Results: Immediate complete occlusion (Raymond Ⅰ) was achieved in 18 aneurysms (90.0%) while 2 aneurysms (10.0%) had a residual neck (Raymond Ⅱ).The median follow-up time(M(QR)) was 8.5(16.3)months,which had no significantly different from the initial treatment follow-up duration (15.5(27.0)months)(U=157.7,P=0.25). During the follow-up period,2 aneurysms (10.0%) with immediate post-operative residual necks recanalized again,including 1 aneurysm re-treated with the Y-configuration stent.Symptomatic thromboembolic complications occurred in 6 patients,including 4 re-treated with the Y-configuration stent.No peri-operative hemorrhagic complications occurred,along with no operation-related permanent disability or death. The parent artery angle increased significantly from pre-operative(90.1±21.1)°to post-operative and the last follow-up ((115.4±28.9)° and (132.6±26.8)°);t=5.14,P<0.01;t=7.78,P<0.01). Conclusion: For recurrent intracranial bifurcation aneurysms after initial surgical clipping or simple coiling,stent assisted coil embolization is proved to be safe and can decrease recurrence rate.


Subject(s)
Embolization, Therapeutic , Intracranial Aneurysm , Stents , Adult , Aged , Cerebral Angiography , Embolization, Therapeutic/adverse effects , Embolization, Therapeutic/instrumentation , Female , Follow-Up Studies , Humans , Intracranial Aneurysm/diagnostic imaging , Intracranial Aneurysm/surgery , Male , Middle Aged , Recurrence , Reoperation , Retrospective Studies , Surgical Stapling/adverse effects , Surgical Stapling/instrumentation , Treatment Failure , Treatment Outcome
11.
Chirurgia (Bucur) ; 116(1): 102-108, 2021.
Article in English | MEDLINE | ID: mdl-33638331

ABSTRACT

Background: Stapled hemorrhoidopexy (Longo operation) is a infrequent technique in our area. A different concept from hemorrhoidectomy, a proportionally important raise in cost and a special training may have contributed to it. We report our long-term results with the standard technique. Methods: The data of 35 patients with symptomatic second- and third-degree hemorrhoids who had stapled hemorrhoidopexy using a PPH03 stapler, from 01 January 2012 to 04 December 2020, were retrospectively collected. The sex ratio male: female was 3:4 and the mean age 45 (range 28-60) years. The follow-up consisted in a rectal exam and evaluated anatomical recurrence or prolapse. Results: The mean operative time was 42 (30-70) min. The mean parenteral analgesic doses during the first 24 h were 1,52. The mean postoperative hospital stay was 1.55 (1-2) days. A single patient needed reoperation for a staple line bleeding, two patients had a thrombosis of internal hemorrhoids and in one patient a small prolapse was diagnosed at 3 months follow-up. No hematoma, anastomotic stenosis, persistent anal pain, tenesmus, or impaired anal continence was recorded. One patient mentioned discomfort related to the presence of staples. Patients were followed-up for 6 (1-9) years. Global satisfaction rate was 94%. Conclusion: Stapled hemorrhoidopexy procedure is a safe and feasible procedure, which necessitates few analgesics and allows an early discharge. A rigorous selection of cases and a correct surgical technique allow to obtain good long-term results and offer a high level of patients satisfaction.


Subject(s)
Hemorrhoids , Surgical Stapling , Adult , Female , Hemorrhoids/surgery , Humans , Male , Middle Aged , Retrospective Studies , Surgical Stapling/instrumentation , Surgical Stapling/methods , Treatment Outcome
12.
Ann Ital Chir ; 92: 183-189, 2021.
Article in English | MEDLINE | ID: mdl-33576338

ABSTRACT

INTRODUCTION: Anastomotic leakage (AL) is one of the most disastrous complications after rectosigmoid cancer operations. The aim of this study is to investigate the effect of the insertion time of circular stapler anvil on assessing the blood supply of the proximal colon segment, and thus to evaluate the prevention of early anastomotic leaks. MATERIAL METHODS: A total of 57 patients were included in the study, 25 patients in group A and 32 patients in group B, respectively. From the beginning of the operation to the time of anvil placement in group A, it was 32.08 (± 7.34) minutes, and in group B it was 92.19 (± 16.63) minutes. None of the patients in group A had AL, and 4 patients in group B had AL. DISCUSSION: Our study shows that the anvil must be placed at the beginning of the dissection to evaluate the anomalies that cause anastomotic leaks. We think that this method increases the reliability of the anastomosis line. Thus, the hospitalization period of the patients was shortened and they returned to their active lives faster. In addition, patients used less antibiotics and they needed less medical treatment. KEY WORDS: Anastomotic leaks, Anvil, Rectosigmoid cancer placement, Stapler colorectal.


Subject(s)
Anastomosis, Surgical/adverse effects , Anastomotic Leak , Proctectomy/adverse effects , Rectal Neoplasms/surgery , Surgical Stapling , Aged , Anastomotic Leak/etiology , Anastomotic Leak/prevention & control , Female , Humans , Male , Middle Aged , Proctectomy/instrumentation , Proctectomy/methods , Rectum/blood supply , Rectum/surgery , Reproducibility of Results , Surgical Stapling/adverse effects , Surgical Stapling/instrumentation , Surgical Stapling/methods , Time Factors
13.
Vet Surg ; 50(2): 435-443, 2021 Feb.
Article in English | MEDLINE | ID: mdl-33387450

ABSTRACT

OBJECTIVE: To determine the influence of stapling on leakage pressures after canine partial gastrectomy. STUDY DESIGN: Ex vivo study. SAMPLE POPULATION: Gastric specimens from 24 adult canine cadavers. METHODS: Partial gastrectomy constructs were assigned to one of three closure techniques (n = 8 per group): group 1, stapled closure with a 90-mm thoracoabdominal stapling device and a 4.8-mm staple cartridge; group 2, hand-sewn double-layer inverting suture closure with 3-0 glycomer 631; and group 3, staple line reinforcement with an inverting Cushing suture pattern. Leakage and pressure testing were performed. Initial leakage pressure (ILP), maximal leakage pressure (MLP), and leakage location were recorded. Significance was set at P < .05. RESULTS: Placement of a Cushing suture (group 3) increased ILP and MLP by 3.2-fold and 2.8-fold, respectively, compared with stapled closures alone (P < .001). Constructs closed with double-layer suture closure reached ILP and MLP 4.5-fold and threefold greater, respectively, compared with those with stapled closures alone (P < .001). Maximal leakage pressure did not differ between groups 2 and 3 (P = .14). Leakage occurred from the inverting suture line in all constructs of groups 2 and 3 and from staple holes in six of eight group 1 constructs. CONCLUSION: Double-layer suture closure of canine partial gastrectomies achieved superior biomechanical properties compared with stapled closure techniques. Reinforcing staple closures with an inverting suture line improved resistance to leakage. CLINICAL SIGNIFICANCE: Reinforcing single-layer closure of partial gastrectomies with an inverting Cushing pattern is recommended to improve resistance to leakage. In vivo investigation is warranted to evaluate influence of closure technique on gastric healing, postoperative stasis, ischemic injury, and postoperative dehiscence.


Subject(s)
Gastrectomy/veterinary , Surgical Stapling/veterinary , Animals , Biomechanical Phenomena , Cadaver , Dogs , Gastrectomy/methods , Surgical Stapling/instrumentation
14.
BMC Surg ; 21(1): 47, 2021 Jan 21.
Article in English | MEDLINE | ID: mdl-33478457

ABSTRACT

BACKGROUND: Recently, due to increasing reports of stenosis after esophagojejunostomy created using circular staplers and a transorally inserted anvil (OrVil™) following laparoscopic proximal gastrectomy (LPG) and total gastrectomy (LTG), linear staplers are being used instead. We investigated our preventive procedure for esophagojejunostomy stenosis following use of circular staplers. METHODS: Since the anastomotic stenosis is considered to be mainly caused by tension in the esophageal and jejunal stumps at the anastomotic site, we have been performing procedures to relieve this tension, by cutting off the rubber band and pushing the shaft of the circular stapler toward the esophageal side, since July 2015. We retrospectively compared the incidence of anastomotic stenosis in cases of LPG and LTG performed before July 2015 (early phase, 30 cases) versus those performed after this period (later phase, 22 cases). RESULTS: Comparison of the incidence of anastomotic stenosis according to the type of surgery, LPG or LTG, and between the two time periods versus all cases, indicated a significantly lower incidence in the later phase than in the early phase (4.5 vs. 26.7%, p < 0.05), especially for LPG (0 vs. 38.5%, p < 0.05). CONCLUSIONS: It is possible to use a circular stapler during laparoscopic esophagojejunostomy, as with open surgery, if steps to reduce tension on the anastomotic site are undertaken. These procedures will contribute to the spread of safe and simple laparoscopic anastomotic techniques.


Subject(s)
Anastomosis, Surgical/adverse effects , Anastomosis, Surgical/methods , Constriction, Pathologic/prevention & control , Esophagus/surgery , Jejunum/surgery , Stomach Neoplasms , Aged , Anastomosis, Surgical/instrumentation , Constriction, Pathologic/etiology , Female , Gastrectomy/adverse effects , Gastrectomy/methods , Humans , Laparoscopy/adverse effects , Laparoscopy/methods , Male , Middle Aged , Retrospective Studies , Stomach Neoplasms/surgery , Surgical Stapling/instrumentation , Surgical Stapling/methods
15.
Surg Today ; 51(3): 447-451, 2021 Mar.
Article in English | MEDLINE | ID: mdl-32772151

ABSTRACT

Accumulation of experience and advances in techniques and instruments have enabled surgeons to perform video-assisted thoracic surgery (VATS) safely for sublobar resection, including segmentectomy and wedge resection. A key to successful VATS sublobar resection is to have adequate resection margins and the appropriate use of articulated surgical staplers is essential for this purpose. The SigniaTM stapling system (Covidien Japan, Tokyo) has been used extensively in the fields of thoracic surgery. Its features include high maneuverability with fully powered articulation, rotation, clamping, and firing, which the surgeon can control with one hand. We introduce the "sliding technique" using the SigniaTM system, which allows for adjustment of the resection lines of the pulmonary parenchyma to optimize safe surgical margins with minimal stapler movement, and without repetitively moving the stapler in and out of the pleural cavity, during VATS sublobar resection.


Subject(s)
Lung Neoplasms/surgery , Lung/surgery , Margins of Excision , Pneumonectomy/instrumentation , Pneumonectomy/methods , Surgical Staplers , Surgical Stapling/instrumentation , Surgical Stapling/methods , Thoracic Surgery, Video-Assisted/instrumentation , Thoracic Surgery, Video-Assisted/methods , Humans , Safety
16.
Surg Today ; 51(4): 575-581, 2021 Apr.
Article in English | MEDLINE | ID: mdl-32974752

ABSTRACT

PURPOSE: Using a circular stapler to create an anastomosis for esophagogastrostomy after esophagectomy is well accepted; however, it remains uncertain if the greater curvature (GC) or lesser curvature (LC) of the gastric conduit is better for the anastomosis. We conducted this prospective study to compare the integrity of esophagogastrostomy between the esophagus and the GC or LC side of the gastric conduit. METHODS: The subjects of this study were 70 patients who underwent esophagectomy and were randomized to a "GC" group and an "LC" group (n = 35 each). The primary and secondary end points were anastomotic leakage (AL) and anastomotic stricture (AS), respectively. RESULTS: The overall AL rate was 22.1%, without a significant difference between the groups. Stump leakage developed in eight of nine patients in the GC group, whereas leakage developed at the esophagogastric anastomosis in five of six patients in the LC group. The rate of stump leakage was significantly higher than that of esophagogastric AL in the GC group. The overall AS rate was 4.4%, with a significant difference between the groups (0% in the GC group vs. 9.1% in the LC group). CONCLUSIONS: AL rates were comparable in the two groups, but the sites of leakage were significantly different.


Subject(s)
Esophageal Neoplasms/surgery , Esophagectomy/methods , Esophagus/surgery , Gastrostomy/methods , Surgical Staplers , Surgical Stapling/instrumentation , Anastomosis, Surgical/instrumentation , Anastomosis, Surgical/methods , Anastomotic Leak/epidemiology , Anastomotic Leak/etiology , Female , Humans , Male , Postoperative Complications/epidemiology , Postoperative Complications/etiology , Prospective Studies , Surgical Staplers/adverse effects , Surgical Stapling/adverse effects , Surgical Stapling/methods , Treatment Outcome
17.
Ann Thorac Cardiovasc Surg ; 27(2): 91-96, 2021 Apr 20.
Article in English | MEDLINE | ID: mdl-32999140

ABSTRACT

PURPOSE: Single-port video-assisted thoracoscopic (VATS) pulmonary wedge resection was reported in 2004. We started using single-port VATS (SPVATS) pulmonary wedge resection in 2017 and compared results between conventional three-port VATS (VATS group) and SPVATS (SPVATS group). METHODS: We identified 145 consecutive patients with VATS group and SPVATS group. Perioperative characteristics including pain and the number of stapler cartridges used were examined as the surgical outcomes, retrospectively. RESULTS: In all, 66 cases of SPVATS group and 79 cases of VATS group pulmonary wedge resection were compared. The rate of epidural anesthesia (p <0.0001) was significantly higher and operative time (p <0.0001) was significantly longer with VATS group than with SPVATS group. The number of stapler cartridges used, duration of drain insertion, and rate of postoperative complications did not differ significantly between groups. Average numerical rating scale (NRS) score on postoperative day 1 and postoperative day 7 (p <0.0001 each), maximum NRS score on postoperative day 7 (p = 0.0082) and amount of 25 mg tramadol (p = 0.0062) were significantly lower in SPVAS group than in VATS group. CONCLUSION: Our results suggest that SPVATS pulmonary wedge resection offers better pain control and cost-effectiveness than three-port VATS pulmonary wedge resection. These findings should contribute to the body of evidence for SPVATS.


Subject(s)
Hospital Costs , Pain, Postoperative/etiology , Pneumonectomy/adverse effects , Pneumonectomy/economics , Thoracic Surgery, Video-Assisted/adverse effects , Thoracic Surgery, Video-Assisted/economics , Adult , Aged , Aged, 80 and over , Analgesics, Opioid/therapeutic use , Cost-Benefit Analysis , Female , Humans , Male , Middle Aged , Operative Time , Pain Measurement , Pain, Postoperative/diagnosis , Pain, Postoperative/drug therapy , Pneumonectomy/instrumentation , Retrospective Studies , Surgical Staplers/economics , Surgical Stapling/adverse effects , Surgical Stapling/economics , Surgical Stapling/instrumentation , Thoracic Surgery, Video-Assisted/instrumentation , Time Factors , Tramadol/therapeutic use , Treatment Outcome
18.
Zhonghua Wei Chang Wai Ke Za Zhi ; 23(12): 1135-1138, 2020 Dec 25.
Article in Chinese | MEDLINE | ID: mdl-33353265

ABSTRACT

Prolapsed hemorrhoids is a common clinical disease, and severe symptoms can significantly affect work and life. The transanal stapler has the advantages of simple operation and less trauma in treating prolapsed hemorrhoids. Its clinical efficacy is closely related to the selection of indications, the standardization of surgical operations, and the prevention and treatment of complications. In current clinical practice, there is no consensus on the treatment of prolapsed hemorrhoids with transanal stapler. Hence a discussion was held by the Professional Committee of Colorectal Diseases of Chinese Society of Integrated Chinese and Western Medicine, concerning the indications, contraindications, operating specifications and perioperative management of prolapsed hemorrhoids. A consensus was consequently formed, aiming to provide a guideline for the clinical practice.


Subject(s)
Hemorrhoidectomy/instrumentation , Hemorrhoids , Anal Canal/surgery , China , Consensus , Hemorrhoidectomy/methods , Hemorrhoids/surgery , Humans , Surgical Stapling/instrumentation , Surgical Stapling/methods , Treatment Outcome
19.
Zhonghua Wei Chang Wai Ke Za Zhi ; 23(11): 1110-1112, 2020 Nov 25.
Article in Chinese | MEDLINE | ID: mdl-33212564

ABSTRACT

Laparoscopic left colectomy (LLC) has been widely performed for treating patients with left hemicolon cancer. For less invasion, totally laparoscopic left colectomy intracorporeal anastomosis (TLC/IA) has been increasingly attempted and proposed. Up to now, there is no standard for intracorporeal anastomosis. Authors list various types of intracorporeal anastomosis in terms of technical details and postoperative complications. According to the literatures, side to side anastomosis with linear laparoscopic stapler is the mainstream method. Surgeons should make flexible choices based on personal technical characteristics, colon conditions and objective economic conditions of patients. An individualized anastomosis method is acceptable.


Subject(s)
Anastomosis, Surgical/methods , Colectomy/methods , Colon/surgery , Colonic Neoplasms , Laparoscopy , Anastomosis, Surgical/instrumentation , Colectomy/instrumentation , Colonic Neoplasms/surgery , Humans , Laparoscopy/instrumentation , Laparoscopy/methods , Surgical Stapling/instrumentation , Surgical Stapling/methods , Treatment Outcome
20.
Plast Reconstr Surg ; 146(6): 777e-789e, 2020 12.
Article in English | MEDLINE | ID: mdl-33234974

ABSTRACT

BACKGROUND: Deep dermal suturing is critical for scar quality outcomes. The authors evaluated a new, fast medical device for dermal suturing, with the hypothesis of noninferiority with regard to clinical scar and cost-effectiveness. METHODS: A prospective, patient-blind, randomized, multicenter noninferiority study in 26 French hospitals was conducted. Patients were randomized 1:1 to suturing with conventional thread or a semiautomatic stapler. The Patient Scar Assessment Scale was rated at 3 months for primary endpoint effectiveness. Secondary endpoints were cost-effectiveness of the two suturing methods, prevalence of complications, suturing/operating time, Observer Scar Assessment Scale and Patient Scar Assessment Scale score, scar aesthetic quality 18 months after surgery, and occupational exposure to blood during surgery. RESULTS: Six hundred sixty-four patients were enrolled, 660 were randomized, and 649 constituted the full analysis (stapler arm, n = 324; needle arm, n = 325). Primary endpoint Patient Scar Assessment Scale score in the stapler arm was not inferior to that in the needle arm at 3 months or after 18 months. The mean operating time was 180 minutes in the stapler arm and 179 minutes in the needle arm (p = not significant). The mean suturing time was significantly lower in the stapler arm (p < 0.001). There were seven occupational exposures to blood in the needle arm and one in the stapler arm. The two arms did not differ significantly in terms of complications (p = 0.41). The additional cost of using the device was &OV0556;51.57 for the complete-case population. CONCLUSION: Wound healing outcome was no worse than with conventional suturing using a semiautomatic stapler and associated with less occupational exposure to blood. CLINICAL QUESTION/LEVEL OF EVIDENCE: Therapeutic, I.


Subject(s)
Cicatrix/prevention & control , Dermatologic Surgical Procedures/methods , Surgical Stapling/methods , Sutures/adverse effects , Adolescent , Adult , Aged , Cicatrix/diagnosis , Cicatrix/etiology , Cost-Benefit Analysis , Dermatologic Surgical Procedures/adverse effects , Dermatologic Surgical Procedures/economics , Dermatologic Surgical Procedures/instrumentation , Female , Follow-Up Studies , Humans , Male , Middle Aged , Patient Reported Outcome Measures , Prospective Studies , Severity of Illness Index , Single-Blind Method , Skin/pathology , Surgical Staplers/economics , Surgical Stapling/adverse effects , Surgical Stapling/economics , Surgical Stapling/instrumentation , Treatment Outcome , Wound Healing , Young Adult
SELECTION OF CITATIONS