Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 718
Filter
1.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38743765

ABSTRACT

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Subject(s)
Consensus , Magnetic Resonance Imaging , Tomography, X-Ray Computed , Humans , Catheter Ablation , Electrophysiologic Techniques, Cardiac , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/diagnostic imaging , Atrial Fibrillation/surgery , Atrial Fibrillation/diagnostic imaging , Atrial Fibrillation/physiopathology , Predictive Value of Tests , Europe , Treatment Outcome
2.
Semin Nucl Med ; 54(3): 427-437, 2024 May.
Article in English | MEDLINE | ID: mdl-38658301

ABSTRACT

Ventricular tachycardia (VT) is a life-threatening arrhythmia common in patients with structural heart disease or nonischemic cardiomyopathy. Many VTs originate from regions of fibrotic scar tissue, where delayed electrical signals exit scar and re-enter viable myocardium. Cardiac stereotactic body radiotherapy (SBRT) has emerged as a completely noninvasive alternative to catheter ablation for the treatment of recurrent or refractory ventricular tachycardia. While there is no common consensus on the ideal imaging workflow, therapy planning for cardiac SBRT often combines information from a plurality of imaging modalities including MRI, CT, electroanatomic mapping and nuclear imaging. MRI and CT provide detailed anatomic information, and late enhancement contrast imaging can indicate regions of fibrosis. Electroanatomic maps indicate regions of heterogenous conduction voltage or early activation which are indicative of arrhythmogenic tissue. Some early clinical adopters performing cardiac SBRT report the use of myocardial perfusion and viability nuclear imaging to identify regions of scar. Nuclear imaging of hibernating myocardium, inflammation and sympathetic innervation have been studied for ventricular arrhythmia prognosis and in research relating to catheter ablation of VT but have yet to be studied in their potential applications for cardiac SBRT. The integration of information from these many imaging modalities to identify a target for ablation can be challenging. Multimodality image registration and dedicated therapy planning tools may enable higher target accuracy, accelerate therapy planning workflows and improve patient outcomes. Understanding the pathophysiology of ventricular arrhythmias, and localizing the arrhythmogenic tissues, is vital for successful ablation with cardiac SBRT. Nuclear imaging provides an arsenal of imaging strategies to identify regional scar, hibernation, inflammation, and sympathetic denervation with some advantages over alternative imaging strategies.


Subject(s)
Radiosurgery , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/radiotherapy , Tachycardia, Ventricular/surgery , Radiosurgery/methods , Radionuclide Imaging
6.
Europace ; 26(2)2024 Feb 01.
Article in English | MEDLINE | ID: mdl-38262674

ABSTRACT

AIMS: Non-invasive myocardial scar characterization with cardiac magnetic resonance (CMR) has been shown to accurately identify conduction channels and can be an important aid for ventricular tachycardia (VT) ablation. A new mapping method based on targeting deceleration zones (DZs) has become one of the most commonly used strategies for VT ablation procedures. The aim of the study was to analyse the capability of CMR to identify DZs and to find predictors of arrhythmogenicity in CMR channels. METHODS AND RESULTS: Forty-four consecutive patients with structural heart disease and VT undergoing ablation after CMR at a single centre (October 2018 to July 2021) were included (mean age, 64.8 ± 11.6 years; 95.5% male; 70.5% with ischaemic heart disease; a mean ejection fraction of 32.3 ± 7.8%). The characteristics of CMR channels were analysed, and correlations with DZs detected during isochronal late activation mapping in both baseline maps and remaps were determined. Overall, 109 automatically detected CMR channels were analysed (2.48 ± 1.15 per patient; length, 57.91 ± 63.07 mm; conducting channel mass, 2.06 ± 2.67 g; protectedness, 21.44 ± 25.39 mm). Overall, 76.1% of CMR channels were associated with a DZ. A univariate analysis showed that channels associated with DZs were longer [67.81 ± 68.45 vs. 26.31 ± 21.25 mm, odds ratio (OR) 1.03, P = 0.010], with a higher border zone (BZ) mass (2.41 ± 2.91 vs. 0.87 ± 0.86 g, OR 2.46, P = 0.011) and greater protectedness (24.97 ± 27.72 vs. 10.19 ± 9.52 mm, OR 1.08, P = 0.021). CONCLUSION: Non-invasive detection of targets for VT ablation is possible with CMR. Deceleration zones found during electroanatomical mapping accurately correlate with CMR channels, especially those with increased length, BZ mass, and protectedness.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Male , Middle Aged , Aged , Female , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Magnetic Resonance Imaging/methods , Myocardium/pathology , Heart Rate/physiology , Arrhythmias, Cardiac , Cicatrix/pathology , Catheter Ablation/methods
9.
Med Phys ; 51(1): 292-305, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37455674

ABSTRACT

BACKGROUND: Cardiac radioablation (CR) is an innovative treatment to ablate cardiac arrythmia sources by radiation therapy. CR target delineation is a challenging task requiring the exploitation of highly different imaging modalities, including cardiac electro-anatomical mapping (EAM). PURPOSE: In this work, a data integration process is proposed to alleviate the tediousness of CR target delineation by generating a fused representation of the heart, including all the information of interest resulting from the analysis and registration of electro-anatomical data, PET scan and planning computed tomography (CT) scan. The proposed process was evaluated by cardiologists during delineation trials. METHODS: The data processing pipeline was composed of the following steps. The cardiac structures of interest were segmented from cardiac CT scans using a deep learning method. The EAM data was registered to the cardiac CT scan using a point cloud based registration method. The PET scan was registered using rigid image registration. The EAM and PET information, as well as the myocardium thickness, were projected on the surface of the 3D mesh of the left ventricle. The target was identified by delineating a path on this surface that was further projected to the thickness of the myocardium to create the target volume. This process was evaluated by comparison with a standard slice-by-slice delineation with mental EAM registration. Four cardiologists delineated targets for three patients using both methods. The variability of target volumes, and the ease of use of the proposed method, were evaluated. RESULTS: All cardiologists reported being more confident and efficient using the proposed method. The inter-clinician variability in delineated target volume was systematically lower with the proposed method (average dice score of 0.62 vs. 0.32 with a classical method). Delineation times were also improved. CONCLUSIONS: A data integration process was proposed and evaluated to fuse images of interest for CR target delineation. It effectively reduces the tediousness of CR target delineation, while improving inter-clinician agreement on target volumes. This study is still to be confirmed by including more clinicians and patient data to the experiments.


Subject(s)
Tachycardia, Ventricular , Tomography, X-Ray Computed , Humans , Workflow , Tomography, X-Ray Computed/methods , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/radiotherapy , Tachycardia, Ventricular/surgery , Positron-Emission Tomography , Myocardium
10.
J Interv Card Electrophysiol ; 67(3): 559-569, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37592198

ABSTRACT

BACKGROUND: The use of a multi-electrode Optrell mapping catheter during ventricular tachycardia (VT) or premature ventricular complex (PVC) ablation procedures has not been widely reported. OBJECTIVES: We aim to describe the feasibility and safety of using the Optrell multipolar mapping catheter (MPMC) to guide catheter ablation of VT and PVCs. METHODS: We conducted a single-center, retrospective evaluation of patients who underwent VT or PVC ablation between June and November 2022 utilizing the MPMC. RESULTS: A total of 20 patients met the inclusion criteria (13 VT and 7 PVC ablations, 80% male, 61 ± 15 years). High-density mapping was performed in the VT procedures with median 2753 points [IQR 1471-17,024] collected in the endocardium and 12,830 points [IQR 2319-30,010] in the epicardium. Operators noted challenges in manipulation of the MPMC in trabeculated endocardial regions or near valve apparatus. Late potentials (LPs) were detected in 11 cases, 7 of which had evidence of isochronal crowding demonstrated during late annotation mapping. Two patients who also underwent entrainment mapping had critical circuitry confirmed in regions of isochronal crowding. In the PVC group, high-density voltage and activation mapping was performed with a median 1058 points [IQR 534-3582] collected in the endocardium. CONCLUSIONS: This novel MPMC can be used safely and effectively to create high-density maps in LV endocardium or epicardium. Limitations of the catheter include a longer wait time for matrix formation prior to starting point collection and challenges in manipulation in certain regions.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Ventricular Premature Complexes , Humans , Male , Female , Retrospective Studies , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Ventricular Premature Complexes/surgery , Electrodes , Catheters , Catheter Ablation/methods
14.
Eur Heart J Cardiovasc Imaging ; 25(2): 188-198, 2024 Jan 29.
Article in English | MEDLINE | ID: mdl-37819047

ABSTRACT

AIMS: Conducting channels (CCs) detected by late gadolinium enhancement cardiac magnetic resonance (LGE-CMR) are related to ventricular tachycardia (VT). The aim of this work was to study the ability of post-ablation LGE-CMR to evaluate ablation lesions. METHODS AND RESULTS: This is a prospective study of consecutive patients referred for a scar-related VT ablation. LGE-CMR was performed 6-12 months prior to ablation and 3-6 months after ablation. Scar characteristics of pre- and post-ablation LGE-CMR were compared. During the study period (March 2019-April 2021), 61 consecutive patients underwent scar-related VT ablation after LGE-CMR. Overall, 12 patients were excluded (4 had poor-quality LGE-CMR, 2 died before post-ablation LGE-CMR, and 6 underwent post-ablation LGE-CMR 12 months after ablation). Finally, 49 patients (age: 65.5 ± 9.8 years, 97.9% male, left ventricular ejection fraction: 34.8 ± 10.4%, 87.7% ischaemic cardiomyopathy) were included. Post-ablation LGE-CMR showed a decrease in the number (3.34 ± 1.03 vs. 1.6 ± 0.2; P < 0.0001) and mass (8.45 ± 1.3 vs. 3.5 ± 0.6 g; P < 0.001) of CCs. Arrhythmogenic CCs disappeared in 74.4% of patients. Dark core was detected in 75.5% of patients, and its presence was not related to CC reduction (52.2 ± 7.4% vs. 40.8 ± 10.6%, P = 0.57). VT recurrence after one year follow-up was 16.3%. The presence of two or more channels in the post-ablation LGE-CMR was a predictor of VT recurrence (31.82% vs. 0%, P = 0.0038) with a sensibility of 100% and specificity of 61% (area under the curve 0.82). In the same line, a reduction of CCs < 55% had sensibility of 100% and specificity of 61% (area under the curve 0.83) to predict VT recurrence. CONCLUSION: Post-ablation LGE-CMR is feasible, and a reduction in the number of CCs is related with lower risk of VT recurrence. The dark core was not present in all patients. A decrease in VT substrate was also observed in patients without a dark core area in the post-ablation LGE-CMR.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Male , Middle Aged , Aged , Female , Myocardium/pathology , Contrast Media , Magnetic Resonance Imaging, Cine/methods , Cicatrix/pathology , Prospective Studies , Gadolinium , Magnetic Resonance Imaging/methods , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Tachycardia, Ventricular/pathology , Magnetic Resonance Spectroscopy
15.
Phys Med ; 115: 103160, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37847954

ABSTRACT

PURPOSE: Identifying the target region is critical for successfully treating ventricular tachycardia (VT) with single fraction stereotactic arrhythmia radioablation (STAR). We report the feasibility of target definition based on direct co-registration of electroanatomic maps (EAM) and radioablation planning images. MATERIALS AND METHODS: The EAM consists of 3D cardiac anatomy representation with electrical activity at endocardium and is acquired by a cardiac electrophysiologist (CEP) during electrophysiology study. The CEP generates an EAM using a 3D cardiac mapping system anticipating radioablation planning. Our in-house software read these non-DICOM EAMs, registered them to a planning image set, and converted them to DICOM structure files. The EAM based target volume was finalized based on a consensus of CEPs, radiation oncologists and medical physicists, then expanded to ITV and PTV. The simulation, planning, and treatment is performed with a standard STAR technique: a single fraction of 25 Gy using volumetric-modulated arc therapy or dynamic conformal arc therapy depending on the target shape. RESULTS: Seven patients with refractory VT were treated by defining the target based on registering EAMs on the planning images. Dice similarity indices between reference map and reference contours after registration were 0.814 ± 0.053 and 0.575 ± 0.199 for LV and LA/RV, respectively. CONCLUSIONS: The quality of the transferred EAMs on the MR/CT images was sufficient to localize the treatment region. Five of 7 patients demonstrated a dramatic reduction in VT events after 6 weeks. Longer follow-up is required to determine the true safety and efficacy of this therapy using EAM-based direct registration method.


Subject(s)
Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Tachycardia, Ventricular , Humans , Heart , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/radiotherapy , Imaging, Three-Dimensional , Radiotherapy, Intensity-Modulated/methods
16.
JACC Clin Electrophysiol ; 9(12): 2507-2519, 2023 12.
Article in English | MEDLINE | ID: mdl-37804259

ABSTRACT

BACKGROUND: Electrophysiological mapping of ventricular tachycardia (VT) is tedious and poorly reproducible. Substrate analysis on imaging cannot explicitly display VT circuits. OBJECTIVES: This study sought to introduce a computed tomography-based model personalization approach, allowing for the simulation of postinfarction VT in a clinically compatible time frame. METHODS: In 10 patients (age 65 ± 11 years, 9 male) referred for post-VT ablation, computed tomography-derived wall thickness maps were registered to 25 electroanatomical maps (sinus rhythm, paced, and VT). The relationship between wall thickness and electrophysiological characteristics (activation-recovery interval) was analyzed. Wall thickness was then employed to parameterize a fast and tractable organ-scale wave propagation model. Pacing protocols were simulated from multiple sites to test VT induction in silico. In silico VTs were compared to VT circuits mapped clinically. RESULTS: Clinically, 6 different VTs could be induced with detailed maps in 9 patients. The proposed model allowed for fast simulation (median: 6 min/pacing site). Simulations of steady pacing (600 milliseconds) from 100 different sites/patient never triggered any arrhythmia. Applying S1-S2 or S1-S2-S3 induction schemes allowed for the induction of in silico VTs in the 9 of 10 patients who were clinically inducible. The patient who was not inducible clinically was also noninducible in silico. A total of 42 different VTs were simulated (4.2 ± 2 per patient). Six in silico VTs matched a VT circuit mapped clinically. CONCLUSIONS: The proposed framework allows for personalized simulations in a matter of hours. In 6 of 9 patients, simulations show re-entrant patterns matching intracardiac recordings.


Subject(s)
Tachycardia, Ventricular , Humans , Male , Middle Aged , Aged , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Tomography, X-Ray Computed
17.
J Cardiovasc Electrophysiol ; 34(11): 2403-2405, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37787011

ABSTRACT

INTRODUCTION: Intracardiac echocardiography (ICE) reveals mobile thrombus on implantable electronic device leads in some patients undergoing electrophysiologic procedures. METHODS: ICE was performed in a patient undergoing ventricular tachycardia (VT) ablation. RESULTS: ICE showed extensive mobile thrombi on the implantable cardioverter defibrillator lead. Radiofrequency catheter ablation of VT from perimitral scar was safely performed via a retrograde aortic approach. After the procedure, chronic anticoagulation was initiated. CT-angiography of the chest 2 months later showed no pulmonary emboli. CONCLUSIONS: The significance of these thrombi, as related to chronic pulmonary embolization, warrants further study.


Subject(s)
Catheter Ablation , Heart Diseases , Tachycardia, Ventricular , Thrombosis , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Wind , Heart Diseases/surgery , Thrombosis/diagnostic imaging , Thrombosis/etiology , Catheter Ablation/methods , Hair , Treatment Outcome
18.
Expert Rev Med Devices ; 20(10): 797-803, 2023.
Article in English | MEDLINE | ID: mdl-37584235

ABSTRACT

INTRODUCTION: Advanced cardiac imaging is an important component in pre-procedural planning for ventricular tachycardia (VT) ablations. inHEART's proprietary software, inHEART Models, and its academic version, Multimodality Platform for Specific Imaging in Cardiology (MUSIC), provide detailed characterization of anatomical structures and scars. AREAS COVERED: This review highlights the current overview of the market and offers insight into inHEART Models and MUSIC and its application during VT ablations with supporting case examples. An overview of the clinical profile and regulatory status of inHEART Models, and other competing technologies, such as Automatic Detection of Arrhythmia Substrate (ADAS) 3D software and Catheter Precision's View into Ventricular Onset (VIVO), are also discussed. EXPERT OPINION: inHEART and MUSIC utilization has increased over the last few years and continues to establish its presence as an important aspect of VT ablations. Its unique proprietary software sets itself apart from others in the field. The introduction of dual source-photon counting detector computed tomography (PCD-CT) is expected to make significant advancements in the field and take imaging to a new level. inHEART's continued research in cardiac imaging and digital technology is expected to increase as is its global presence in the electrophysiology (EP) community.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Heart , Heart Ventricles , Arrhythmias, Cardiac/surgery , Tomography, X-Ray Computed , Catheter Ablation/methods
19.
JACC Clin Electrophysiol ; 9(9): 1914-1929, 2023 09.
Article in English | MEDLINE | ID: mdl-37480871

ABSTRACT

BACKGROUND: The anatomical substrate for left posterior fascicular ventricular tachycardia (LPF-VT) is still unclear. OBJECTIVES: The purpose of this study is to describe the endocavitary substrate of the re-entrant loop of LPF-VT. METHODS: A total of 26 consecutive patients with LPF-VT underwent an electrophysiology study and radiofrequency ablation. RESULTS: Intracardiac echocardiography imaging observed a 100% prevalence of false tendons (FTs) at the left posterior septal region in all patients, and 3 different types of FTs could be classified according to their location. In 22 patients, a P1 potential could be recorded via the multielectrode catheter from a FT. In 4 patients without a recorded P1 during LPF-VT, the earliest P2 potentials were recorded from a FT in 3 patients, and from a muscular connection between 2 posteromedial papillary muscles in 1 patient. Catheter ablation focused on the FTs with P1 or earliest P2 (in patients without P1) was successful in all 26 patients. After 19 ± 8.5 months of follow-up, no patients had recurrence of LPF-VT. CONCLUSIONS: FTs provide an electroanatomical substrate for LPF-VT and a "culprit FT" may be identified as the critical structure bridging the macro-re-entrant loop. Targeting the "culprit FT" is a novel anatomical ablation strategy that results in long-term arrhythmia-free survival.


Subject(s)
Catheter Ablation , Tachycardia, Ventricular , Humans , Heart Ventricles , Electrocardiography/methods , Bundle-Branch Block , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Electrophysiologic Techniques, Cardiac , Catheter Ablation/methods
20.
JACC Clin Electrophysiol ; 9(6): 779-789, 2023 06.
Article in English | MEDLINE | ID: mdl-37380313

ABSTRACT

BACKGROUND: A new functional mapping strategy based on targeting deceleration zones (DZs) has become one of the most commonly used strategies within the armamentarium of substrate-based ablation methods for ventricular tachycardia (VT) in patients with structural heart disease. The classic conduction channels detected by voltage mapping can be accurately determined by cardiac magnetic resonance (CMR). OBJECTIVES: The purpose of this study was to analyze the evolution of DZs during ablation and their correlation with CMR. METHODS: Forty-two consecutive patients with scar-related VT undergoing ablation after CMR in Hospital Clinic (October 2018-December 2020) were included (median age 65.3 ± 11.8 years; 94.7% male; 73.7% ischemic heart disease). Baseline DZs and their evolution in isochronal late activation remaps were analyzed. A comparison between DZs and CMR conducting channels (CMR-CCs) was realized. Patients were prospectively followed for VT recurrence for 1 year. RESULTS: Overall, 95 DZs were analyzed, 93.68% of which were correlated with CMR-CCs: 44.8% located in the middle segment and 55.2% located in the entrance/exit of the channel. Remapping was performed in 91.7% of patients (1 remap: 33.3%, 2 remaps: 55.6%, and 3 remaps: 2.8%). Regarding the evolution of DZs, 72.2% disappeared after the first ablation set, with 14.13% not ablated at the end of the procedure. A total of 32.5% of DZs in remaps correlated with a CMR-CCs already detected, and 17.5% were associated with an unmasked CMR-CCs. One-year VT recurrence was 22.9%. CONCLUSIONS: DZs are highly correlated with CMR-CCs. In addition, remapping can lead to the identification of hidden substrate initially not identified by electroanatomic mapping but detected by CMR.


Subject(s)
Deceleration , Tachycardia, Ventricular , Humans , Male , Middle Aged , Aged , Female , Magnetic Resonance Imaging , Heart , Tachycardia, Ventricular/diagnostic imaging , Tachycardia, Ventricular/surgery , Magnetic Resonance Spectroscopy
SELECTION OF CITATIONS
SEARCH DETAIL
...