Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 2.086
Filter
1.
ACS Appl Mater Interfaces ; 16(19): 24384-24397, 2024 May 15.
Article in English | MEDLINE | ID: mdl-38709640

ABSTRACT

Vascularization and inflammation management are essential for successful bone regeneration during the healing process of large bone defects assisted by artificial implants/fillers. Therefore, this study is devoted to the optimization of the osteogenic microenvironment for accelerated bone healing through rapid neovascularization and appropriate inflammation inhibition that were achieved by applying a tantalum oxide (TaO)-based nanoplatform carrying functional substances at the bone defect. Specifically, TaO mesoporous nanospheres were first constructed and then modified by functionalized metal ions (Mg2+) with the following deferoxamine (DFO) loading to obtain the final product simplified as DFO-Mg-TaO. Scanning electron microscopy (SEM) and transmission electron microscopy (TEM) revealed that the product was homogeneously dispersed hollow nanospheres with large specific surface areas and mesoporous shells suitable for loading Mg2+ and DFO. The biological assessments indicated that DFO-Mg-TaO could enhance the adhesion, proliferation, and osteogenic differentiation of bone marrow mesenchymal stem cells (BMSCs). The DFO released from DFO-Mg-TaO promoted angiogenetic activity by upregulating the expressions of hypoxia-inducible factor-1 (HIF-1α) and vascular endothelial growth factor (VEGF). Notably, DFO-Mg-TaO also displayed anti-inflammatory activity by reducing the expressions of pro-inflammatory factors, benefiting from the release of bioactive Mg2+. In vivo experiments demonstrated that DFO-Mg-TaO integrated with vascular regenerative, anti-inflammatory, and osteogenic activities significantly accelerated the reconstruction of bone defects. Our findings suggest that the optimized DFO-Mg-TaO nanospheres are promising as multifunctional fillers to speed up the bone healing process.


Subject(s)
Bone Regeneration , Deferoxamine , Magnesium , Mesenchymal Stem Cells , Oxides , Tantalum , Deferoxamine/chemistry , Deferoxamine/pharmacology , Bone Regeneration/drug effects , Tantalum/chemistry , Animals , Oxides/chemistry , Oxides/pharmacology , Magnesium/chemistry , Magnesium/pharmacology , Mesenchymal Stem Cells/drug effects , Mesenchymal Stem Cells/cytology , Mesenchymal Stem Cells/metabolism , Osteogenesis/drug effects , Neovascularization, Physiologic/drug effects , Rats , Mice , Rats, Sprague-Dawley , Cell Proliferation/drug effects , Angiogenesis
2.
Biomed Mater ; 19(4)2024 May 15.
Article in English | MEDLINE | ID: mdl-38697199

ABSTRACT

Porous tantalum scaffolds offer a high degree of biocompatibility and have a low friction coefficient. In addition, their biomimetic porous structure and mechanical properties, which closely resemble human bone tissue, make them a popular area of research in the field of bone defect repair. With the rapid advancement of additive manufacturing, 3D-printed porous tantalum scaffolds have increasingly emerged in recent years, offering exceptional design flexibility, as well as facilitating the fabrication of intricate geometries and complex pore structures that similar to human anatomy. This review provides a comprehensive description of the techniques, procedures, and specific parameters involved in the 3D printing of porous tantalum scaffolds. Concurrently, the review provides a summary of the mechanical properties, osteogenesis and antibacterial properties of porous tantalum scaffolds. The use of surface modification techniques and the drug carriers can enhance the characteristics of porous tantalum scaffolds. Accordingly, the review discusses the application of these porous tantalum materials in clinical settings. Multiple studies have demonstrated that 3D-printed porous tantalum scaffolds exhibit exceptional corrosion resistance, biocompatibility, and osteogenic properties. As a result, they are considered highly suitable biomaterials for repairing bone defects. Despite the rapid development of 3D-printed porous tantalum scaffolds, they still encounter challenges and issues when used as bone defect implants in clinical applications. Ultimately, a concise overview of the primary challenges faced by 3D-printed porous tantalum scaffolds is offered, and corresponding insights to promote further exploration and advancement in this domain are presented.


Subject(s)
Biocompatible Materials , Bone Substitutes , Bone and Bones , Osteogenesis , Printing, Three-Dimensional , Tantalum , Tissue Engineering , Tissue Scaffolds , Tantalum/chemistry , Tissue Scaffolds/chemistry , Porosity , Humans , Biocompatible Materials/chemistry , Tissue Engineering/methods , Animals , Bone Substitutes/chemistry , Materials Testing , Bone Regeneration
3.
Nanotechnology ; 35(30)2024 May 10.
Article in English | MEDLINE | ID: mdl-38663375

ABSTRACT

In this research, we utilize porous tantalum, known for its outstanding elastic modulus and biological properties, as a base material in biomedical applications. The human skeletal system is rich in elements like Ca and Zn. The role of Zn is crucial for achieving a spectrum of sterilizing effects, while Ca is known to effectively enhance cell differentiation and boost cellular activity. The focus of this study is the modification of porous tantalum using a hydrothermal method to synthesize Ca2+/Zn2+-doped Ta2O5nanorods. These nanorods are subjected to extensive characterization techniques to confirm their structure and composition. Additionally, their biological performance is evaluated through a range of tests, including antibacterial assessments, MTT assays, and bacteria/cell scanning electron microscopy (SEM) analyses. The objective is to determine the most effective method of surface modification for porous tantalum, thereby laying a foundational theoretical framework for its surface enhancement.


Subject(s)
Anti-Bacterial Agents , Calcium , Tantalum , Zinc , Tantalum/chemistry , Anti-Bacterial Agents/pharmacology , Anti-Bacterial Agents/chemistry , Zinc/chemistry , Zinc/pharmacology , Calcium/chemistry , Humans , Staphylococcus aureus/drug effects , Surface Properties , Porosity , Escherichia coli/drug effects , Microbial Sensitivity Tests
4.
Medicine (Baltimore) ; 103(14): e37697, 2024 Apr 05.
Article in English | MEDLINE | ID: mdl-38579049

ABSTRACT

BACKGROUND: Total knee arthroplasty involves the use of cemented tibial components for fixation. In recent years, cementless porous tantalum tibial components have been increasingly utilized. The aim of this meta-analysis was to compare the efficacy of cementless porous tantalum tibial components with traditional cemented tibial components in terms of postoperative outcomes following total knee arthroplasty. METHODS: Relevant literature was retrieved from Cochrane Library, PubMed, Embase, and Web of Science using the search terms "(trabecular metal OR Porous tantalum)" AND "knee" up to July 2023. The weighted mean difference with a 95% confidence interval was used as the effect size measure to evaluate the functional recovery of the knee joint, radiological analysis, complications, and implant revisions between cementless porous tantalum tibial components and traditional cemented tibial components after total knee arthroplasty. Review Manager 5.3 was utilized to conduct a comparative analysis of all included studies. RESULTS: Nine studies with a total of 1117 patients were included in this meta-analysis, consisting of 447 patients in the porous tantalum group and 670 patients in the cemented group. Radiological analysis demonstrated that the porous tantalum group had better outcomes than the cemented group (P < .05). The combined results for the 5-year and 10-year follow-ups, range of motion, Western Ontario and McMaster University Osteoarthritis Index, complications, and implant revisions showed no significant differences between the porous tantalum and cemented groups. CONCLUSION: The results of the 5-year and 10-year follow-ups indicate that the use of cementless porous tantalum tibial components is comparable to traditional cemented tibial components, with no significant advantages observed. However, at the 5-year follow-up, the porous tantalum group demonstrated a good bone density in the proximal tibia. Future studies with a larger sample size, long-term clinical follow-up, and radiological results are needed to verify the differences between the 2 implants.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Osteoarthritis, Knee , Humans , Arthroplasty, Replacement, Knee/methods , Tantalum , Tibia/surgery , Porosity , Treatment Outcome , Knee Joint/surgery , Prosthesis Design , Bone Cements , Osteoarthritis, Knee/surgery
5.
Bone Joint J ; 106-B(5 Supple B): 74-81, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688495

ABSTRACT

Aims: The aim of this study was to compare the biomechanical models of two frequently used techniques for reconstructing severe acetabular defects with pelvic discontinuity in revision total hip arthroplasty (THA) - the Trabecular Metal Acetabular Revision System (TMARS) and custom triflange acetabular components (CTACs) - using virtual modelling. Methods: Pre- and postoperative CT scans from ten patients who underwent revision with the TMARS for a Paprosky IIIB acetabular defect with pelvic discontinuity were retrospectively collated. Computer models of a CTAC implant were designed from the preoperative CT scans of these patients. Computer models of the TMARS reconstruction were segmented from postoperative CT scans using a semi-automated method. The amount of bone removed, the implant-bone apposition that was achieved, and the restoration of the centre of rotation of the hip were compared between all the actual TMARS and the virtual CTAC implants. Results: The median amount of bone removed for TMARS reconstructions was significantly greater than for CTAC implants (9.07 cm3 (interquartile range (IQR) 5.86 to 21.42) vs 1.16 cm3 (IQR 0.42 to 3.53) (p = 0.004). There was no significant difference between the median overall implant-bone apposition between TMARS reconstructions and CTAC implants (54.8 cm2 (IQR 28.2 to 82.3) vs 56.6 cm2 (IQR 40.6 to 69.7) (p = 0.683). However, there was significantly more implant-bone apposition within the residual acetabulum (45.2 cm2 (IQR 28.2 to 72.4) vs 25.5 cm2 (IQR 12.8 to 44.1) (p = 0.001) and conversely significantly less apposition with the outer cortex of the pelvis for TMARS implants compared with CTAC reconstructions (0 cm2 (IQR 0 to 13.1) vs 23.2 cm2 (IQR 16.4 to 30.6) (p = 0.009). The mean centre of rotation of the hip of TMARS reconstructions differed by a mean of 11.1 mm (3 to 28) compared with CTAC implants. Conclusion: In using TMARS, more bone is removed, thus achieving more implant-bone apposition within the residual acetabular bone. In CTAC implants, the amount of bone removed is minimal, while the implant-bone apposition is more evenly distributed between the residual acetabulum and the outer cortex of the pelvis. The differences suggest that these implants used to treat pelvic discontinuity might achieve short- and long-term stability through different biomechanical mechanisms.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Reoperation , Tantalum , Tomography, X-Ray Computed , Humans , Acetabulum/surgery , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Female , Male , Aged , Retrospective Studies , Middle Aged , Biomechanical Phenomena , Aged, 80 and over , Prosthesis Failure , Porosity
6.
Bone Joint J ; 106-B(5 Supple B): 54-58, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38688499

ABSTRACT

Aims: The use of a porous metal shell supported by two augments with the 'footing' technique is one solution to manage Paprosky IIIB acetabular defects in revision total hip arthroplasty. The aim of this study was to assess the medium-term implant survival and radiological and clinical outcomes of this technique. Methods: We undertook a retrospective, two-centre series of 39 hips in 39 patients (15 male, 24 female) treated with the 'footing' technique for Paprosky IIIB acetabular defects between 2007 and 2020. The median age at the time of surgery was 64.4 years (interquartile range (IQR) 54.4 to 71.0). The median follow-up was 3.9 years (IQR 3.1 to 7.0). Results: The cumulative medium-term survival of the acetabular construct was 89%. Two hips (5.1%) required further revision due to shell loosening, one hip (2.6%) due to shell dislocation, and one hip (2.6%) due to infection. The median Harris Hip Score improved significantly from 47 points (IQR 41.5 to 54.9) preoperatively to 80 points (IQR 73.5 to 88.6) at the latest follow-up (p < 0.001). Conclusion: The reconstruction of Paprosky IIIB acetabular defects with porous tantalum shells and two augments using the 'footing' technique showed excellent medium-term results. It is a viable option for treating these challenging defects.


Subject(s)
Acetabulum , Arthroplasty, Replacement, Hip , Hip Prosthesis , Prosthesis Design , Prosthesis Failure , Reoperation , Tantalum , Humans , Male , Female , Middle Aged , Arthroplasty, Replacement, Hip/methods , Arthroplasty, Replacement, Hip/instrumentation , Retrospective Studies , Aged , Acetabulum/surgery , Porosity
7.
ACS Biomater Sci Eng ; 10(3): 1435-1447, 2024 Mar 11.
Article in English | MEDLINE | ID: mdl-38330203

ABSTRACT

Addressing the repair of large-scale bone defects has become a hot research topic within the field of orthopedics. This study assessed the feasibility and effectiveness of using porous tantalum scaffolds to treat such defects. These scaffolds, manufactured using the selective laser melting (SLM) technology, possessed biomechanical properties compatible with natural bone tissue. To enhance the osteogenesis bioactivity of these porous Ta scaffolds, we applied calcium phosphate (CaP) and magnesium-doped calcium phosphate (Mg-CaP) coatings to the surface of SLM Ta scaffolds through a hydrothermal method. These degradable coatings released calcium and magnesium ions, demonstrating osteogenic bioactivity. Experimental results indicated that the Mg-CaP group exhibited biocompatibility comparable to that of the Ta group in vivo and in vitro. In terms of osteogenesis, both the CaP group and the Mg-CaP group showed improved outcomes compared to the control group, with the Mg-CaP group demonstrating superior performance. Therefore, both CaP and magnesium-CaP coatings can significantly enhance the osseointegration of three-dimensional-printed porous Ta, thereby increasing the surface bioactivity. Overall, the present study introduces an innovative approach for the biofunctionalization of SLM porous Ta, aiming to enhance its suitability as a bone implant material.


Subject(s)
Magnesium , Tantalum , Porosity , Magnesium/pharmacology , Titanium , Calcium Phosphates/pharmacology , Lasers
8.
Sci Rep ; 14(1): 1023, 2024 01 10.
Article in English | MEDLINE | ID: mdl-38200230

ABSTRACT

Using three-dimensional (3D) printing technology to make the porous tantalum plate and modify its surface. The physicochemical properties, cytocompatibility, antioxidant capacity, and histocompatibility of the modified materials were evaluated to prepare for the repair of craniomaxillofacial bone defects. The porous tantalum plates were 3D printed by selective laser melting technology. Tantalum plates were surface modified with a metal polyphenol network. The surface-modified plates were analyzed for cytocompatibility using thiazolyl blue tetrazolium bromide and live/dead cell staining. The antioxidant capacity of the surface-modified plates was assessed by measuring the levels of intracellular reactive oxygen species, reduced glutathione, superoxide dismutase, and malondialdehyde. The histocompatibility of the plates was evaluated by animal experiments. The results obtained that the tantalum plates with uniform small pores exhibited a high mechanical strength. The surface-modified plates had much better hydrophilicity. In vitro cell experiments showed that the surface-modified plates had higher cytocompatibility and antioxidant capacity than blank tantalum plates. Through subcutaneous implantation in rabbits, the surface-modified plates demonstrated good histocompatibility. Hence, surface-modified tantalum plates had the potential to be used as an implant material for the treatment of craniomaxillofacial bone defects.


Subject(s)
Animal Experimentation , Lagomorpha , Animals , Rabbits , Antioxidants , Tantalum , Bone Plates , Polyphenols
9.
Biomed Mater Eng ; 35(2): 99-124, 2024.
Article in English | MEDLINE | ID: mdl-38217572

ABSTRACT

BACKGROUND: Intervertebral cages used in clinical applications were often general products with standard specifications, which were challenging to match with the cervical vertebra and prone to cause stress shielding and subsidence. OBJECTIVE: To design and fabricate customized tantalum (Ta) intervertebral fusion cages that meets the biomechanical requirements of the cervical segment. METHODS: The lattice intervertebral cages were customized designed and fabricated by the selective laser melting. The joint and muscle forces of the cervical segment under different movements were analyzed using reverse dynamics method. The stress characteristics of cage, plate, screws and vertebral endplate were analyzed by finite element analysis. The fluid flow behaviors and permeability of three lattice structures were simulated by computational fluid dynamics. Compression tests were executed to investigate the biomechanical properties of the cages. RESULTS: Compared with the solid cages, the lattice-filled structures significantly reduced the stress of cages and anterior fixation system. In comparison to the octahedroid and quaddiametral lattice-filled cages, the bitriangle lattice-filled cage had a lower stress shielding rate, higher permeability, and superior subsidence resistance ability. CONCLUSION: The inverse dynamics simulation combined with finite element analysis is an effective method to investigate the biomechanical properties of the cervical vertebra during movements.


Subject(s)
Spinal Fusion , Tantalum , Biomechanical Phenomena , Spinal Fusion/methods , Bone Plates , Finite Element Analysis , Printing, Three-Dimensional , Lumbar Vertebrae/surgery
10.
Mikrochim Acta ; 191(2): 112, 2024 01 29.
Article in English | MEDLINE | ID: mdl-38286966

ABSTRACT

For the first time, a tumour hypoxia marker detection has been developed using two-dimensional layered composite modified electrodes in biological and environmental samples. The concept of TaB2 and V4C3-based MXene composite materials is not reported hitherto using ball-milling and thermal methods and it remains the potentiality of the present work. The successful formation is confirmed through various characterisation techniques like X-ray crystallography, scanning electron microscopy photoelectron, and impedance spectroscopy. A reliable and repeatable electrochemical sensor based on TaB2@V4C3/SPCE was developed for quick and extremely sensitive detection of pimonidazole by various electroanalytical methods. It has been shown that the modified electrode intensifies the reduction peak current and causes a decrease in the potential for reduction, in comparison with the bare electrode. The proposed sensor for pimonidazole reduction has strong electrocatalytic activity and high sensitivity, as demonstrated by the cyclic voltammetry approach. Under the optimal experimental circumstances, differential pulse voltammetry techniques were utilised for generating the wide linear range (0.02 to 928.51 µM) with a detection limit of 0.0072 µM. The resultant data demonstrates that TaB2@V4C3/SPCE nano-sensor exhibits excellent stability, reliability, and repeatability in the determination of pimonidazole. Additionally, the suggested sensor was successfully used to determine the presence of pimonidazole in several real samples, such as human blood serum, urine, water, and drugs.


Subject(s)
Carbon , Nitroimidazoles , Tantalum , Humans , Carbon/chemistry , Vanadium , Reproducibility of Results , Limit of Detection , Electrodes , Boron Compounds
11.
ACS Biomater Sci Eng ; 10(1): 377-390, 2024 Jan 08.
Article in English | MEDLINE | ID: mdl-38078685

ABSTRACT

Tantalum is receiving increasing attention in the biomedical field due to its biocompatible nature and superior mechanical properties. However, the bioinert nature of tantalum still poses a challenge and limits its integration into the bone tissue. To address these issues, we fabricated nanotubular (NT), nanocoral (NC), and nanodimple morphologies on tantalum surfaces via anodization. The size of these nanofeatures was engineered to be approximately 30 nm for all anodized samples. Thus, the influence of the anodized nanostructured morphology on the chemical and biological properties of tantalum was evaluated. The NT and NC samples exhibited higher surface roughness, surface energy, and hydrophilicity compared to the nonanodized samples. In addition, the NT samples exhibited the highest corrosion resistance among all of the investigated samples. Biological experiments indicated that NT and NC samples promoted human adipose tissue-derived mesenchymal stem cell (hADMSC) spreading and proliferation up to 5 days in vitro. ALP, COL1A1, and OSC gene expressions as well as calcium mineral synthesis were upregulated on the NT and NC samples in the second and third weeks in vitro. These findings highlight the significance of nanostructured feature morphology for anodized tantalum, where the NT morphology was shown to be a potential candidate for orthopedic applications.


Subject(s)
Oxides , Tantalum , Humans , Tantalum/chemistry , Corrosion , Oxides/chemistry , Cell Differentiation
12.
Osteoarthritis Cartilage ; 32(3): 299-309, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38061579

ABSTRACT

OBJECTIVE: Cationic tantalum oxide nanoparticles (Ta2O5-cNPs), as a newly introduced contrast agent for computed tomography of cartilage, offer quantitative evaluation of proteoglycan (PG) content and biomechanical properties. However, knowledge on the depth-wise impact of cartilage constituents on nanoparticle diffusion, particularly the influence of the collagen network, is lacking. In this study, we aim to establish the depth-dependent relationship between Ta2O5-cNP diffusion and cartilage constituents (PG content, collagen content and network architecture). METHODS: Osteochondral samples (n = 30) were harvested from healthy equine stifle joints (N = 15) and the diffusion of 2.55 nm diameter cationic Ta2O5-cNPs into the cartilage was followed with micro computed tomography (µCT) imaging for up to 96 hours. The diffusion-related parameters, Ta2O5-cNP maximum partition (Pmax) and diffusion time constant, were compared against biomechanical and depth-wise structural properties. Biomechanics were assessed using stress-relaxation and sinusoidal loading protocols, whereas PG content, collagen content and collagen network architecture were determined using digital densitometry, Fourier-transform infrared spectroscopy and polarized light microscopy, respectively. RESULTS: The Pmax correlates with the depth-wise distribution of PGs (bulk Spearman's ρ = 0.87, p < 0.001). More open collagen network architecture at the superficial zone enhances intake of Ta2O5-cNPs, but collagen content overall decreases the intake. The Pmax values correlate with the equilibrium modulus (ρ = 0.80, p < 0.001) of articular cartilage. CONCLUSION: This study establishes the feasibility of Ta2O5-cNPs for the precise and comprehensive identification of biomechanical and structural changes in articular cartilage via contrast-enhanced µCT.


Subject(s)
Cartilage, Articular , Oxides , Tantalum , Animals , Horses , Cartilage, Articular/diagnostic imaging , Contrast Media , X-Ray Microtomography , Proteoglycans , Collagen
13.
Radiography (Lond) ; 30(1): 282-287, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38041916

ABSTRACT

INTRODUCTION: The utilization of radiation shielding material positioned between the both breasts are crucial for the reduction of glandular dose and the safeguarding of the contralateral breast during mammographic procedures. This study proposes an alternative substance for shielding the contralateral breast from radiation exposure during mammography screening. METHODS: In this study, we present an analysis of the shielding effectiveness of transparent glass that has been doped with Tantalum (V) oxide encoded as BTZT6. The evaluation of this shielding material was conducted using the MCNPX code, specifically for the ipsilateral and contralateral breasts. The design of the left and right breast phantoms involved the creation of three-layer heterogeneous breast phantoms, consisting of varying proportions of glandular tissue (25%, 50%, and 75%). The design of BTZT6 and lead-acrylic shielding screens is implemented using the MCNPX code. The comparative analysis of dose outcomes is conducted to assess the protective efficacy of BTZT6 and lead-acrylic shielding screens. RESULTS: The utilization of BTZT6 shielding material resulted in a reduction in both breast dose and skin dose exposure when compared to the lead-acrylic shield. CONCLUSION: Based on the findings acquired, the utilization of BTZT6 shielding material screens during mammography procedures involving X-rays with energy levels ranging from 26 to 30 keV is associated with a decrease in radiation dose. IMPLICATIONS FOR PRACTICE: It can be inferred that the utilization of BTZT6 demonstrates potential efficacy in mitigating excessive radiation exposure to the breasts and facilitating the quantification of glandular doses in mammography procedures.


Subject(s)
Tantalum , Tomography, X-Ray Computed , Humans , Radiation Dosage , Tomography, X-Ray Computed/methods , Mammography/methods , Breast/diagnostic imaging
14.
Orthop Traumatol Surg Res ; 110(2): 103739, 2024 Apr.
Article in English | MEDLINE | ID: mdl-37918693

ABSTRACT

BACKGROUND: Porous tantalum components and augments have demonstrated short to midterm fixation stability in acetabular total hip arthroplasty (THA) revision but do not offer a novel option to decrease the postoperative dislocation rate. Recently, dual mobility (DM) cups have gained interest to decrease the prevalence of recurrent hip instability after revision hip arthroplasty, but this issue was not confirmed combined with use of tantalum reconstruction devices. Therefore, we did a retrospective study aiming to: (1) evaluate at a 5-year minimum follow-up period the dislocation rate (and other intra- and postoperative complications), (2) assess radiographic results specifically looking at osseointegration and restoration of the hip center, (3) and also clinical results in a cohort of patients who underwent complex acetabular reconstruction with trabecular metal revision components associated with a cemented DM socket. HYPOTHESIS: Using a DM socket cemented in porous tantalum components can reach the low risk of hip dislocation reported with DM components in revision setting without increasing the risk of a mechanical failure. METHODS: A cross-sectional study identified 174 THA revision including an acetabular revision. Were excluded 118 revisions with acetabular defects Type 1, 2a or 2B according to Paprosky's classification, as well as 18 hips revised without a dual mobility and 3 patients (3 hips) lost to follow-up. Were thus included in this study 35 hips (35 patients) implanted with uncemented total hip arthroplasty revision using both trabecular metal acetabular cup-cage reconstruction and a cemented DM cup. Seven hips were classified Paprosky types 2C, 15 type 3A and 13 types 3B. Patients were followed with clinical and radiological evaluation regarding dislocation rate, infection, reoperation or re-revision, osseointegration and restoration of the hip center, and functional results according to the Harris hip score and psoas impingement presence. RESULTS: At a mean follow-up of 8.1±1.8 years (5.1-12.6), one dislocation was recorded, and one acute deep infection. No patient required a cup re-revision for septic or aseptic loosening. The survivorship at 8years regarding revision for any cause as an endpoint was 96.5% (CI95%: 92-99). Osseointegration of TM implants was analyzed and found no acetabular migration at the last follow-up in the cohort. The mean hip center position was optimized from 48±7mm (37-58) to 34±5mm (29-39) vertically and from 26±5mm (-18-36) to 24±8mm (7-31) horizontally without reaching significance (p=0.1). On the last follow-up X-rays, the mean acetabular inclination was 47̊±9̊ (32̊-61̊). According to the criteria of Hirakawa, 97.1% (34/35) of the hip centers were restored. One cup (2.9%) was more than 5mm proximally from the hip center, and none more than 10mm. Clinical results assessed a Harris Hip Score improved from 36±17 (23-62) preoperatively to 82±15 (69-93) at last follow-up (p<0.0001). Two patients (2/35, 5.7%) complained of psoas impingement. CONCLUSION: This study suggests effectiveness of DM cups in association with a tantalum-made acetabular shell for reconstruction of large bone defect in THRs for both solving postoperative instability and aseptic loosening without increasing the re-revision rate for any reason in a midterm follow-up. LEVEL OF EVIDENCE: IV; observational study.


Subject(s)
Arthroplasty, Replacement, Hip , Hip Prosthesis , Humans , Tantalum , Retrospective Studies , Cross-Sectional Studies , Follow-Up Studies , Prosthesis Failure , Prosthesis Design , Arthroplasty, Replacement, Hip/methods , Acetabulum/surgery , Reoperation/methods
15.
Chemosphere ; 350: 141020, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38141668

ABSTRACT

Step-scheme (S-scheme) AgI decorated Ta2O5-x heterojunctions have been designed and synthesized via a combination of solvothermal and chemical deposition methods for enhanced visible-light harvesting and high-performance photocatalysis. The AgI nanoparticles showed great influences on the visible-light absorption and charge separation between AgI and Ta2O5-x microspheres. The experimental results indicated that the as-prepare AgI/Ta2O5-x composites achieved enhanced photocatalytic performance towards tetracycline degradation under visible light, and the AgI/Ta2O5-x-11 sample displayed the highest photocatalytic performance and the maximum rate constant of approximately 0.09483 min-1, which was 7.22 times that of Ta2O5-x microspheres and 2.56 times that of AgI, respectively. The highly enhanced photocatalytic performance was mainly attributed to the construction of S-scheme heterostructure and formation of oxygen vacancies in Ta2O5-x microspheres. In addition, the trapping experimental and DMPO spin-trapping ESR spectra confirmed the ⸱O2- and ⸱OH species as the main radicals during tetracycline degradation. Current work indicates an S-scheme tantalum-based composites for high-performance environmental photocatalysis.


Subject(s)
Environmental Pollutants , Tantalum , Photolysis , Anti-Bacterial Agents , Oxygen , Tetracycline
16.
J Orthop Traumatol ; 24(1): 62, 2023 Dec 13.
Article in English | MEDLINE | ID: mdl-38091159

ABSTRACT

BACKGROUND: Transforaminal lumbar interbody fusion (TLIF), a commonly used procedure in spine surgery, has the advantage of a lower incidence of nerve lesions compared to the posterior lumbar interbody fusion (PLIF) technique. The intersomatic arthrodesis has always been carried out with a single tantalum cage normally used for PLIF. Tantalum is a metal that is particularly used in orthopedic surgery. It has a modulus of elasticity similar to marrow and leads to high primary stability of the implant. MATERIALS AND METHODS: Our study was a retrospective monocentric observational study evaluating clinical and radiological outcomes of tantalum cages in a modified TLIF technique with posterior instrumentation and autologous and/or homologous posterolateral bone grafting. The aim of the study was to evaluate clinical outcomes and the increase in or redistribution of lumbar lordosis. The intersomatic arthrodesis was always carried out with a single tantalum cage normally used for PLIF to reduce the neurological risk. We retrospectively studied 105 patients who were treated with a modified unilateral TLIF approach by two surgeons between 2013 and 2018. We evaluated the Oswestry Disability Index (ODI), Visual Analogue Scale (VAS) for back pain, global lumbar lordosis, lordosis of L4-sacrum, segmental lordosis of functional motion units that underwent arthrodesis, pelvic tilt, pelvic incidence, and the sacral slope in 77 patients. All patients were suffering from grade III or IV Pfirrmann, instability, or foraminal post-laminectomy stenosis and/or grade I-II degenerative spondylolisthesis or low-grade isthmic spondylolisthesis. They had no significant sagittal imbalance, with a sagittal vertical axis (SVA) of < 5 mm. The average follow-up duration was 30 months. RESULTS: We achieved excellent clinical results, with only four cases of failure (5.2%). Moreover, we noticed a statistically significant redistribution of lumbar lordosis, with an average percentage increase in L4-S1 lordosis equal to 19.9% (P < 0.001), an average increase in the L4-S1/Lumbar lordosis (LL) ratio from 0.53 to 0.63 (P < 0.001), and a mean percentage increase in sacral slope equal to 7.6% (P < 0.001). CONCLUSION: Thanks to the properties of tantalum, our modified single-portal TLIF technique is a valid surgical solution to obtain a solid arthrodesis and restore the correct lumbar lordosis distribution while reducing neurological complications and the number of failures. LEVEL OF EVIDENCE: 4 Trial registration statement: retrospective observational study, no trial registration.


Subject(s)
Lordosis , Spinal Fusion , Spondylolisthesis , Humans , Lordosis/diagnostic imaging , Lordosis/surgery , Lordosis/etiology , Retrospective Studies , Sacrum/diagnostic imaging , Sacrum/surgery , Tantalum , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Spinal Fusion/methods , Treatment Outcome
17.
Knee Surg Sports Traumatol Arthrosc ; 31(12): 5496-5506, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37819600

ABSTRACT

PURPOSE: Severe metaphyseal bone defects remain a challenge and represent a growing problem in revision total knee arthroplasty (RTKA). The purpose of this study was to examine the survival of first-generation tantalum metal cones (TMC) and to assess clinical and radiographic data obtained from mid- to long-term follow-ups (FU) after RTKA with severe bony defects. METHODS: This retrospective case series included 100 consecutive patients of the same centre, who underwent RTKA surgery with TMC for tibia and/or femur bone defects between January 2011 and December 2015. Fourteen patients had died and six were lost for FU, leaving a total of eighty patients (one hundred and twelve TMC) for final evaluation. Clinical parameters including the Knee Society Score (KSS), visual analogue scale (VAS), Western Ontario and McMaster Universities Osteoarthritis Index (WOMAC) and range of motion (ROM) were determined preoperatively based on the patients' medical charts, and assessed again during the final FU after an average of 6.1 (5-9) years postoperative. Standardised postoperative X-rays were analysed during the final FU visit for osseointegration of the cones, and any signs of implant loosening were assessed with the modified Knee Society Radiographic review criteria. Perioperative and postoperative complications, reoperations, as well as implant and cone re-revisions were analysed. Survivorship analysis was performed with (a) cone-related revision for any reason and (b) implant component revision for any reason. RESULTS: Previous RTKA had to be performed due to 64 (80%) aseptic and 16 (20%) septic failures. At the final FU, 75 (94%) tibia and 76 (95%) femur TMCs and implants were clinically stable. One patient experienced loosening of cones and implants at the femur and tibia but denied re-revision surgery. There were eight (10%) reoperations including two early wound healing problems, two inlay changes, two periprosthetic fractures, one debridement, antibiotics and implant retention (DAIR), and one secondary patella replacement. The six (7.5%) re-revisions included two aseptic loosening's of the opposite implant without TMC, one arthrodesis for recurrent instability, and three deep infections managed by two two-stage exchanges, and one amputation for persistent infection. At re-revision, all TMC cones were osteointegrated without signs of loosening. The determined clinical parameters showed significant (p < 0.001) postoperative improvement, and objective KSS was rated as excellent in 51%, and as good in 22% of patients at the final FU. The estimated 8-year Kaplan-Meier survival was 95% for TMC and 92.5% for implant components. CONCLUSION: Tantalum metal cones (TMC) demonstrate a secure fixation for treatment of severe femoral and tibial metaphyseal bone defects during RTKA. This fixation concept showed excellent mid- to long-term clinical and radiographic outcomes with promising 8-year survival rates for cones and implant components. LEVEL OF EVIDENCE: Retrospective cohort study, Level IV.


Subject(s)
Arthroplasty, Replacement, Knee , Knee Prosthesis , Humans , Tantalum , Retrospective Studies , Prosthesis Design , Reoperation , Knee Joint/surgery , Treatment Outcome
18.
J Mater Chem B ; 11(42): 10218-10233, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37869981

ABSTRACT

Polymer-based composites are considered promising candidates for bone repair as they possess some outstanding advantages over ceramic/metallic/polymeric biomaterials. Tantalum (Ta)/polyimide (PI) biocomposites (PT) containing 20 v% (PT20) and 40 v% (PT40) Ta nanoparticles were fabricated, and luteolin (LU) was loaded on PT40 (LUPT40). Compared with PT20 and PI, PT40 with a high Ta content displayed high surface behaviors (e.g., roughness, surface energy, and hydrophilicity). PT40 remarkably improved cell adhesion and multiplication, and LUPT40 with LU displayed further enhancement in vitro. Moreover, LUPT40 evidently boosted osteoblastic differentiation while suppressing osteoclastic differentiation. Furthermore, LUPT40 exhibited good antibacterial effects because of the slow release of LU. The in vivo results confirmed that PT40 markedly promoted bone formation and LUPT40 further enhanced bone formation/bone bonding. In brief, the incorporation of Ta particles improved the surface behaviors of PT40, which stimulated cell response/bone formation. Moreover, the slow release of LU from LUPT40 not only promoted cell response/bone formation but also enhanced bone bonding. The synergistic effects of Ta and LU release from LUPT40 enhanced bone formation/bone bonding. Therefore, LUPT40 would have great potential for the repair of bear-loading bone.


Subject(s)
Osteogenesis , Tantalum , Tantalum/pharmacology , Luteolin/pharmacology , Bone and Bones , Cell Differentiation , Polymers/pharmacology
19.
Biomater Adv ; 154: 213638, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37812984

ABSTRACT

The treatment and reconstruction of large or critical size bone defects is a challenging clinical problem. Additive manufacturing breaks the technical difficulties of preparing complex conformation and anatomically matched personalized porous tantalum implants, but the ideal pore structure for 3D-printed porous tantalum in critical bone defect repair applications remains unclear. Guiding appropriate bone tissue regeneration by regulating proper pore size-pore distribution-pore geometry-porosity is a challenge for its fabrication and application. We fabricated porous tantalum (PTa) scaffolds with six different combinations of pore structures using powder bed laser melting (L-PBF) technology. In vitro biological experiments were conducted to systematically investigate the effects of pore structure characteristics on osteoblast behaviors, showing that the bionic trabecular structure with both large and small poress facilitated cell permeation, proliferation and differentiation compared to the cubic structure with uniform pore sizes. The osteogenesis of PTa with different porosity of trabecular structures was further investigated by a rabbit condyle critical bone defect model. Synthetically, T70% up-regulated the expression of osteogenesis-related genes (ALP, COLI, OCN, RUNX-2) and showed the highest bone ingrowth area and bone contact rate in vivo after 16 weeks, with the best potential for critical bone defect repair. Our results suggested that the bionic trabecular structure with a pore size distribution of 200-1200 µm, an average pore size of 700 µm, and a porosity of 70 % is the best choice for repairing critical bone defects, which is expected to guide the clinical application of clinical 3D-printed PTa scaffolds.


Subject(s)
Osteogenesis , Tantalum , Animals , Rabbits , Porosity , Tantalum/pharmacology , Osteogenesis/genetics , Bone and Bones , Printing, Three-Dimensional
20.
Biomater Adv ; 154: 213624, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37716333

ABSTRACT

The periosteum plays a critical role in bone development, shaping, remodeling, and fracture healing due to its abundance of osteoprogenitor cells, osteoblasts, and capillary network. However, the role of periosteum in bone injury healing has been underestimated, thus there is an urgent need to develop a multifunctional artificial periosteum that mimics the natural one. To tackle this issue, electrospinning technology was employed to fabricate an artificial periosteum composed of Poly-ε-caprolactone (PCL) doped with tantalum (Ta) and zinc oxide (ZnO) nanoparticles to enhance its antibacterial, osteogenic, and angiogenic properties. The in vitro cell experiments have demonstrated that the PCL/Ta/ZnO artificial periosteum exhibits excellent biocompatibility and can effectively facilitate osteogenic differentiation of BMSCs as well as angiogenic differentiation of EPCs. Antibacterial experiments have demonstrated the excellent bactericidal effects of PCL/Ta/ZnO artificial periosteum against both S. aureus and E. coli. The subcutaneous infection and critical-sized skull bone defect models have validated its in vivo properties of antibacterial activity, promotion of osteogenesis, and angiogenic potential. The PCL/Ta/ZnO artificial periosteum demonstrates remarkable efficacy in infection control and favorable immunomodulation, thereby achieving rapid vascularized bone repair. In conclusion, the utilization of PCL/Ta/ZnO tissue-engineered periosteum has been demonstrated to exhibit antibacterial properties, pro-vascularization effects, and promotion of osteogenesis at the site of bone defects. This promising approach could potentially offer effective treatment for bone defects.


Subject(s)
Osteogenesis , Zinc Oxide , Periosteum , Zinc Oxide/pharmacology , Tantalum/pharmacology , Staphylococcus aureus , Escherichia coli , Anti-Bacterial Agents/pharmacology
SELECTION OF CITATIONS
SEARCH DETAIL
...