Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters











Database
Language
Publication year range
1.
J Chromatogr A ; 1643: 462079, 2021 Apr 26.
Article in English | MEDLINE | ID: mdl-33780878

ABSTRACT

In the present study, a comprehensive and sensitive method for simultaneous determination of 21 PIs (nine benzophenones, eight amine co-initiators, and four thioxanthones) in human plasma using high-performance liquid chromatography coupled with tandem mass spectrometry was developed and validated. Two different pre-treatment approaches (liquid-liquid extraction (LLE) and LLE coupled with solid-phase extraction (SPE)) and eight extraction solvents were studied to optimize sample treatment to obtain good recoveries and reduce any matrix effects. The procedure of LLE+SPE was selected as final sample treatment procedure because it obtained higher recoveries as well as lower matrix effects than that performed by LLE alone. The recoveries of 21 target analytes at three spiked concentrations (0.05, 0.5, and 5 ng/mL) ranged from 81% to 109%. The intra- and inter-day relative standard deviations were between 2.5% and 13%. Accuracy and precision data indicated that the detection method was accurate and precise for most of the PIs. The linearities of the labeled dilution calibration curves at 10 concentration levels (iLOQ to 100 ng/mL or iLOQ to 200 ng/mL) were good with correlation coefficients ranged from 0.995 to 0.999. The method quantification limits were in the range of 1.7-16 pg/mL. The analytical method was applied to the analysis of PIs in 14 human plasma samples collected from pregnant women in Guangdong Province, China. Fifteen PIs were detected with total concentrations ranging from 318 to 2772 pg/mL. The ubiquitous contamination of human plasma with PIs suggests that there is widespread exposure to these compounds. Consequently, there should be increased awareness of these pollutants in the environment.


Subject(s)
Benzophenones/blood , Chromatography, High Pressure Liquid/methods , Xanthones/blood , Adult , Benzophenones/isolation & purification , Benzophenones/standards , Chromatography, High Pressure Liquid/standards , Environmental Pollutants/blood , Female , Healthy Volunteers , Humans , Limit of Detection , Liquid-Liquid Extraction , Pregnancy , Quality Control , Solid Phase Extraction , Tandem Mass Spectrometry/methods , Tandem Mass Spectrometry/standards , Thioxanthenes/blood , Thioxanthenes/isolation & purification , Thioxanthenes/standards , Xanthones/isolation & purification , Xanthones/standards
SELECTION OF CITATIONS
SEARCH DETAIL