Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 8.758
Filter
1.
BMC Med Imaging ; 24(1): 102, 2024 May 09.
Article in English | MEDLINE | ID: mdl-38724896

ABSTRACT

Precision and intelligence in evaluating the complexities of middle ear structures are required to diagnose auriculotemporal and ossicle-related diseases within otolaryngology. Due to the complexity of the anatomical details and the varied etiologies of illnesses such as trauma, chronic otitis media, and congenital anomalies, traditional diagnostic procedures may not yield accurate diagnoses. This research intends to enhance the diagnosis of diseases of the auriculotemporal region and ossicles by combining High-Resolution Spiral Computed Tomography (HRSCT) scanning with Deep Learning Techniques (DLT). This study employs a deep learning method, Convolutional Neural Network-UNet (CNN-UNet), to extract sub-pixel information from medical photos. This method equips doctors and researchers with cutting-edge resources, leading to groundbreaking discoveries and better patient healthcare. The research effort is the interaction between the CNN-UNet model and high-resolution Computed Tomography (CT) scans, automating activities including ossicle segmentation, fracture detection, and disruption cause classification, accelerating the diagnostic process and increasing clinical decision-making. The suggested HRSCT-DLT model represents the integration of high-resolution spiral CT scans with the CNN-UNet model, which has been fine-tuned to address the nuances of auriculotemporal and ossicular diseases. This novel combination improves diagnostic efficiency and our overall understanding of these intricate diseases. The results of this study highlight the promise of combining high-resolution CT scanning with the CNN-UNet model in otolaryngology, paving the way for more accurate diagnosis and more individualized treatment plans for patients experiencing auriculotemporal and ossicle-related disruptions.


Subject(s)
Ear Ossicles , Tomography, Spiral Computed , Humans , Tomography, Spiral Computed/methods , Ear Ossicles/diagnostic imaging , Deep Learning , Ear Diseases/diagnostic imaging , Temporal Bone/diagnostic imaging , Adult , Neural Networks, Computer
2.
J Contemp Dent Pract ; 25(3): 250-259, 2024 Mar 19.
Article in English | MEDLINE | ID: mdl-38690699

ABSTRACT

AIM AND BACKGROUND: To compare the root canal volume in primary teeth using hand and rotary instruments and to evaluate root canal filling techniques and flow of root canal obturation materials in the postinstrumented root canal volume using spiral computed tomography (SCT). MATERIALS AND METHODS: Freshly extracted 16 primary molars were randomly divided into two groups and subjected to SCT analysis before and after instrumentation. For the manual technique (group I) with eight teeth were prepared using K files, and rotary (group II) eight teeth preparation was performed with ProTaper files. The filled volume in each canal was measured using SCT, and the percentage of obturated volume was calculated. The data were statistically analyzed using the Mann-Whitney U test. RESULTS: There was a statistically significant difference in both groups' volume of root canals enlarged. Even though both K files and the ProTaper system brought about enlarged canals after instrumentation, there was a statistically significant increase in volume after using K files in two canals. In three canals, there was a statistically significant increase in volume after using ProTaper. Irrespective of the obturation technique and materials used, there is no statistically significant difference in the volume after obturation. CONCLUSION: From the results of this study, the ProTaper file system shows suitable volumetric enlargement up to an optimum level, which is needed in primary root canal walls, and is better in canal shaping, as evidenced by good postobturation volume. CLINICAL SIGNIFICANCE: The traditional method of cleaning and shaping the root canals in permanent teeth using manual stainless-steel files can lead to undesirable curvatures in root canal morphology, making correctly filling the root canals difficult. It is also time-consuming and sometimes leads to iatrogenic errors. Rotary nickel-titanium (Ni-Ti) instrumentation techniques have been developed to overcome these problems. How to cite this article: Yadav DBUC, Varma RB, Kumar JS, et al. Volumetric Analysis of Hand and Rotary Instrumentation, Root Canal Filling Techniques, and Obturation Materials in Primary Teeth Using Spiral CT. J Contemp Dent Pract 2024;25(3):250-259.


Subject(s)
Dental Pulp Cavity , Molar , Root Canal Filling Materials , Root Canal Obturation , Root Canal Preparation , Tomography, Spiral Computed , Tooth, Deciduous , Humans , Root Canal Obturation/methods , Tooth, Deciduous/diagnostic imaging , Root Canal Preparation/instrumentation , Root Canal Preparation/methods , Dental Pulp Cavity/diagnostic imaging , Dental Pulp Cavity/anatomy & histology , Tomography, Spiral Computed/methods , Molar/diagnostic imaging , Dental Instruments , In Vitro Techniques
3.
Sci Rep ; 14(1): 9358, 2024 04 23.
Article in English | MEDLINE | ID: mdl-38653758

ABSTRACT

The goal of this experimental study was to quantify the influence of helical pitch and gantry rotation time on image quality and file size in ultrahigh-resolution photon-counting CT (UHR-PCCT). Cervical and lumbar spine, pelvis, and upper legs of two fresh-frozen cadaveric specimens were subjected to nine dose-matched UHR-PCCT scan protocols employing a collimation of 120 × 0.2 mm with varying pitch (0.3/1.0/1.2) and rotation time (0.25/0.5/1.0 s). Image quality was analyzed independently by five radiologists and further substantiated by placing normed regions of interest to record mean signal attenuation and noise. Effective mAs, CT dose index (CTDIvol), size-specific dose estimate (SSDE), scan duration, and raw data file size were compared. Regardless of anatomical region, no significant difference was ascertained for CTDIvol (p ≥ 0.204) and SSDE (p ≥ 0.240) among protocols. While exam duration differed substantially (all p ≤ 0.016), the lowest scan time was recorded for high-pitch protocols (4.3 ± 1.0 s) and the highest for low-pitch protocols (43.6 ± 15.4 s). The combination of high helical pitch and short gantry rotation times produced the lowest perceived image quality (intraclass correlation coefficient 0.866; 95% confidence interval 0.807-0.910; p < 0.001) and highest noise. Raw data size increased with acquisition time (15.4 ± 5.0 to 235.0 ± 83.5 GByte; p ≤ 0.013). Rotation time and pitch factor have considerable influence on image quality in UHR-PCCT and must therefore be chosen deliberately for different musculoskeletal imaging tasks. In examinations with long acquisition times, raw data size increases considerably, consequently limiting clinical applicability for larger scan volumes.


Subject(s)
Photons , Humans , Tomography, X-Ray Computed/methods , Cadaver , Rotation , Radiation Dosage , Tomography, Spiral Computed/methods
4.
Zhonghua Wei Chang Wai Ke Za Zhi ; 27(3): 268-273, 2024 Mar 25.
Article in Chinese | MEDLINE | ID: mdl-38532589

ABSTRACT

Objective: To evaluate the relationships between the location and extent of diffusion of free intraperitoneal air by multi-slice spiral CT (MSCT) and between the location and size of acute gastrointestinal perforation. Methods: This was a descriptive case series. We examined abdominal CT images of 33 patients who were treated for intraoperatively confirmed gastrointestinal perforation (excluding appendiceal perforation) in the Department of General Surgery, Nanfang Hospital between January and September 2022. We identified five locations of intraperitoneal air: the subphrenic space, hepatic portal space, mid-abdominal wall, mesenteric space, and pelvic cavity. We allocated the 33 patients to an upper gastrointestinal perforation (n=23) and lower gastrointestinal perforation group (n=10) base on intraoperative findings and analyzed the relationships between the locations of free gas and of gastrointestinal perforation. Additionally, we established two models for analyzing the extent of diffusion of free gas in the abdominal cavity and constructed receiver operating characteristic (ROC) curves to analyze the relationships between the two models and the size of the gastrointestinal perforation. Results: In the upper gastrointestinal perforation group, free gas was located around the hepatic portal area in 91.3% (21/23) of patients: this is a significantly greater proportion than that found in the lower gastrointestinal perforation group (5/10) (P=0.016). In contrast, free gas was located in the mesenteric interspace in 8/10 patients in the lower gastrointestinal perforation group; this is a significantly greater proportion than was found in the upper gastrointestinal perforation group (8.7%, 2/23) (P<0.010). The sensitivity of diagnosis of upper gastrointestinal perforation base on the presence of hepatic portal free gas was 84.8% and the specificity 71.4%. Further, the sensitivity of diagnosis of lower gastrointestinal perforation base on the presence of mesenteric interspace free gas was 80.0% and the specificity 91.3%. The rates of presence of free gas in the subdiaphragmatic area, mid-abdominal wall, and pelvic cavity did not differ significantly between the two groups (all P>0.05). Receiver operating characteristic curves showed that when free gas was present in four or more of the studied locations in the abdominal cavity, the optimal cutoff for perforation diameter was 2 cm, the corresponding sensitivity 66.7%, and the specificity 100%, suggesting that abdominal free gas diffuses extensively when the diameter of the perforation is >2 cm. Another model revealed that when free gas is present in three or more of the studied locations, the optimal cutoff for perforation diameter is 1 cm, corresponding to a sensitivity of 91.7% and specificity of 76.2%; suggesting that free gas is relatively confined in the abdominal cavity when the diameter of the perforation is <1 cm. Conclusion: Identifying which of five locations in the abdominal cavity contains free intraperitoneal air by examining MSCT images can be used to assist in the diagnosis of the location and size of acute gastrointestinal perforations.


Subject(s)
Abdominal Cavity , Intestinal Perforation , Upper Gastrointestinal Tract , Humans , Multidetector Computed Tomography , Tomography, Spiral Computed , Liver , Retrospective Studies
5.
Zhongguo Gu Shang ; 37(2): 153-8, 2024 Feb 25.
Article in Chinese | MEDLINE | ID: mdl-38425066

ABSTRACT

OBJECTIVE: To explore the potential value of three-dimensional fast spin echo(3D-SPACE) combined with multilayer spiral CT (MSCT) in the diagnosis of knee cruciate ligament injury, to provide a new direction for the optimization of subsequent clinical diagnosis. METHODS: A total of 120 patients with knee cruciate ligament injury were treated from April 2020 to April 2021, aged from 21 to 68 with an average of(41.52±4.13) years old. For all patients, separate MSCT scanner scans, 3D-SPACE sequence scans alone and 3D-SPACE sequence combined with MSCT scans were used. The injury and classification of the anterior and posterior cruciate ligament of the knee were compared, the length of the anterior-medial bundle and posterolateral bundle and its angle of the knee with the horizontal plane were observed, the diagnostic value of 3 diagnostic methods in knee cruciate ligament injury were determined. RESULTS: There was no significant difference between the 3D-SPACE sequence scan alone and the MSCT test alone on the total diagnostic rate and grading total diagnostic rate(P>0.05). The total diagnostic rate and grading total diagnostic rate of 3D-SPACE scan combined with MSCT were significantly higher than those of 3D-SPACE scan or MSCT alone(P<0.05). The 3D-SPACE sequence scan alone and the MSCT detection alone had no significant difference in the measurement values related to the anterior and posterior cruciate ligaments of the knee joint(P>0.05). 3D-SPACE sequence scanning combined with MSCT detection on the knee joint anterior and posterior cruciate ligament related measurements were significantly higher than the 3D-SPACE sequence scan or MSCT detection alone(P<0.05). The area under the ROC curve estimated by 3D-SPACE sequence scanning combined with MSCT was 0.960, which was significantly higher than that of 3D-SPACE sequence scanning and MSCT alone evaluating the area under the ROC curve line of 0.756 and 0.795. The combined 3D-SPACE sequence scanning and 3D-SPACE sequence scanning MSCT analysis and prediction models were statistically different(Z=2.236, P<0.05), and MSCT alone and 3D-SPACE sequence scanning combined with MSCT analysis and prediction models were statistically different(Z=2.653, P<0.05). CONCLUSION: The application of 3D-SPACE sequence combined with MSCT scanning for knee cruciate ligament injury can improve the diagnosis rate of patients with knee cruciate ligament injury.It can be used as a diagnostic tool for patients with knee cruciate ligament injury and is worthy of clinical application.


Subject(s)
Anterior Cruciate Ligament Injuries , Knee Injuries , Posterior Cruciate Ligament , Soft Tissue Injuries , Humans , Adult , Middle Aged , Magnetic Resonance Imaging/methods , Arthroscopy , Knee Injuries/diagnostic imaging , Knee Joint/diagnostic imaging , Posterior Cruciate Ligament/injuries , Tomography, Spiral Computed , Anterior Cruciate Ligament Injuries/diagnostic imaging
6.
Pediatr Radiol ; 54(5): 758-763, 2024 May.
Article in English | MEDLINE | ID: mdl-38308740

ABSTRACT

BACKGROUND: Adaptive collimation reduces the dose deposited outside the imaged volume along the z-axis. An increase in the dose deposited outside the imaged volume (to the lens and thyroid) in the z-axis direction is a concern in paediatric computed tomography (CT). OBJECTIVE: To compare the dose deposited outside the imaged volume (to the lens and thyroid) between 40-mm and 80-mm collimation during thoracic paediatric helical CT. MATERIALS AND METHODS: We used anthropomorphic phantoms of newborns and 5-year-olds with 40-mm and 80-mm collimation during helical CT. We compared the measured dose deposited outside the imaged volume using optically stimulated luminescence dosimeters (OSLD) at the surfaces of the lens and thyroid and the image noise between the 40-mm and 80-mm collimations. RESULTS: There were significant differences in the dose deposited outside the imaged volume (to the lens and thyroid) between the 40-mm and 80-mm collimations for both phantoms (P < 0.01). CONCLUSION: Compared with that observed for 80-mm collimation in helical CT scans of the paediatric thorax, the dose deposited outside the imaged volume (to the lens and thyroid) was significantly lower in newborns and 5-year-olds with 40-mm collimation.


Subject(s)
Lens, Crystalline , Phantoms, Imaging , Radiation Dosage , Radiography, Thoracic , Thyroid Gland , Humans , Thyroid Gland/diagnostic imaging , Infant, Newborn , Lens, Crystalline/diagnostic imaging , Lens, Crystalline/radiation effects , Radiography, Thoracic/methods , Radiography, Thoracic/instrumentation , Child, Preschool , Tomography, X-Ray Computed/methods , Tomography, Spiral Computed/methods
7.
Med Phys ; 51(3): 1597-1616, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38227833

ABSTRACT

BACKGROUND: Multislice spiral computed tomography (MSCT) requires an interpolation between adjacent detector rows during backprojection. Not satisfying the Nyquist sampling condition along the z-axis results in aliasing effects, also known as windmill artifacts. These image distortions are characterized by bright streaks diverging from high contrast structures. PURPOSE: The z-flying focal spot (zFFS) is a well-established hardware-based solution that aims to double the sampling rate in longitudinal direction and therefore reduce aliasing artifacts. However, given the technical complexity of the zFFS, this work proposes a deep learning-based approach as an alternative solution. METHODS: We propose a supervised learning approach to perform a mapping between input projections and the corresponding rows required for double sampling in the z-direction. We present a comprehensive evaluation using both a clinical dataset obtained using raw data from 40 real patient scans acquired with zFFS and a synthetic dataset consisting of 100 simulated spiral scans using a phantom specifically designed for our problem. For the clinical dataset, we utilized 32 scans as training set and 8 scans as validation set, whereas for the synthetic dataset, we used 80 scans for training and 20 scans for validation purposes. Both qualitative and quantitative assessments are conducted on a test set consisting of nine real patient scans and six phantom measurements to validate the performance of our approach. A simulation study was performed to investigate the robustness against different scan configurations in terms of detector collimation and pitch value. RESULTS: In the quantitative comparison based on clinical patient scans from the test set, all network configurations show an improvement in the root mean square error (RMSE) of approximately 20% compared to neglecting the doubled longitudinal sampling by the zFFS. The results of the qualitative analysis indicate that both clinical and synthetic training data can reduce windmill artifacts through the application of a correspondingly trained network. Together with the qualitative results from the test set phantom measurements it is emphasized that a training of our method with synthetic data resulted in superior performance in windmill artifact reduction. CONCLUSIONS: Deep learning-based raw data interpolation has the potential to enhance the sampling in z-direction and thus minimize aliasing effects, as it is the case with the zFFS. Especially a training with synthetic data showed promising results. While it may not outperform zFFS, our method represents a beneficial solution for CT scanners lacking the necessary hardware components for zFFS.


Subject(s)
Artifacts , Deep Learning , Humans , Tomography, Spiral Computed/methods , Tomography Scanners, X-Ray Computed , Phantoms, Imaging , Image Processing, Computer-Assisted/methods , Algorithms
8.
Zhongguo Fei Ai Za Zhi ; 27(1): 13-24, 2024 Jan 20.
Article in Chinese | MEDLINE | ID: mdl-38296622

ABSTRACT

BACKGROUND: Low-dose spiral computed tomography (LDCT) has been recommended for lung cancer screening in high-risk populations. However, evidence from Chinese populations was limited due to the different criteria for high-risk populations and the short-term follow-up period. This study aimed to evaluate the effectiveness in Chinese adults based on the Lung Cancer Screening Program in Minhang District of Shanghai initiated in 2013. METHODS: A total of 26,124 subjects aged 40 years or above were enrolled in the Lung Cancer Screening Program during the period of 2013 and 2017. Results of LDCT examination, and screen-detected cancer cases in all participants were obtained from the Reporting System of the Lung Cancer Screening Program. The newly-diagnosed cases and their vital status up to December 31, 2020 were identified through a record linkage with the Shanghai Cancer Registry and the Shanghai Vital Statistics. Standardized incidence ratio (SIR) and 95%CI were calculated using the local population at ages of 40 or above as the reference. Proportions of early-stage cancer (stage 0-I), pathological types, and 5-year observed survival rates of lung cancer cases were estimated and compared between the cases derived from the screened and non-screened populations. Cox regression models were applied to evaluate the hazard ratio (HR) and 95%CI of LDCT screening with all-cause death of the lung cancer cases. RESULTS: The crude and age-standardized incidence of lung cancer in screened population were 373.3 (95%CI: 343.1-406.1) and 70.3 per 100,000 person-years, respectively, with an SIR of 1.8 (95%CI: 1.6-1.9), which was observed to decrease with following-up time. The early-stage cancer accounted for 49.4% of all lung cancer cases derived from the screened population, significantly higher than 38.4% in cases from the non-screened population during the same period (P<0.05). The proportion of lung adenocarcinoma (40.7% vs 35.9%) and 5-year survival rate (53.7% vs 41.5%) were also significantly higher in the cases from the screened population (all P<0.05). LDCT screening was associated with 30% (HR=0.7, 95%CI: 0.6-0.8) reduced all-cause deaths of the cases. CONCLUSIONS: The participants of the screening program are at high-risk of lung cancer. LDCT favors the early-detection of lung cancer and improves 5-year survival of the screened cases, indicating a great potential of LDCT in reducing the disease burden of lung cancer in Chinese populations.


Subject(s)
Lung Neoplasms , Adult , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/epidemiology , Tomography, X-Ray Computed , Early Detection of Cancer/methods , China/epidemiology , Tomography, Spiral Computed/methods , Mass Screening
9.
Technol Health Care ; 32(1): 1-8, 2024.
Article in English | MEDLINE | ID: mdl-37270822

ABSTRACT

BACKGROUND: Juxta-papillary duodenal diverticula (JPDD) are common but are usually asymptomatic, and they are often diagnosed by coincidence. OBJECTIVE: To analyse the anatomy and classification of JPDD and its relationship with biliary and pancreatic disorders, and to explore the diagnostic value of multi-slice spiral computed tomography (MSCT) in patients with JPDD. METHODS: The imaging data of patients with JPDD, which was obtained via abdominal computed tomography examination and confirmed via gastroscopy and/or upper gastrointestinal barium enema, in our hospital from 1 January 2019 to 31 December 2020 were retrospectively analysed. All patients were scanned using MSCT, and the imaging findings, classification and grading were analysed. RESULTS: A total of 119 duodenal diverticula were detected in 96 patients, including 73 single diverticula and 23 multiple diverticula. The imaging findings were mainly cystic lesions of the inner wall of the duodenum protruding to the outside of the cavity. The thin layer showed a narrow neck connected with the duodenal cavity, and the shape and size of the diverticula were different: 67 central-type cases and 29 peripheral-type cases. There were 50 cases of type I, 33 cases of type II, 19 cases of type III and six cases of type IV. Furthermore, there were seven small, 87 medium and 14 large diverticula. The differences in the location and size of the JPDD in MSCT grading were statistically significant (P< 0.05). CONCLUSION: The MSCT method has an important diagnostic value for the classification of JPDD, and MSCT images are helpful in the clinical evaluation of patients with JPDD and the selection of treatment options.


Subject(s)
Diverticulum , Duodenal Diseases , Humans , Retrospective Studies , Duodenal Diseases/diagnostic imaging , Diverticulum/diagnostic imaging , Diverticulum/pathology , Tomography, X-Ray Computed , Tomography, Spiral Computed
11.
Altern Ther Health Med ; 30(2): 118-123, 2024 Feb.
Article in English | MEDLINE | ID: mdl-37820681

ABSTRACT

Objective: This study aimed to assess the clinical efficacy of combining multi-slice spiral CT with gastrointestinal angiography for diagnosing gastric cancer. Methods: We conducted a retrospective analysis of clinical data from 151 patients with suspected gastric cancer admitted to our hospital between January 2014 and January 2022. Among them, 70 patients underwent multi-slice spiral CT alone (control group), while the remaining 81 patients underwent multi-slice spiral CT in combination with gastrointestinal barium contrast (combination group). Finally, pathological examination confirmed gastric cancer in 81 patients. We analyzed the diagnostic efficacy of multi-slice spiral CT combined with gastrointestinal angiography for staging gastric cancer and detecting lymph node metastasis. Results: The sensitivity and accuracy of diagnosing gastric cancer using multi-slice spiral CT combined with gastrointestinal angiography were significantly superior to CT alone (P < .05). This combined approach exhibited substantial advancements in detecting stage I and II tumors compared to a single CT, although the difference in stage III detection rate was marginal (P < .05). Furthermore, among the 81 gastric cancer cases, 67 were confirmed to have lymph node metastasis through surgical and pathological examination. The lymph node detection rate with multi-slice spiral CT combined with gastrointestinal angiography was significantly higher than that achieved with single CT (P < .05). Conclusions: Combining multi-slice spiral CT with gastrointestinal angiography proved to be an effective diagnostic strategy for gastric cancer.


Subject(s)
Stomach Neoplasms , Humans , Lymphatic Metastasis/diagnostic imaging , Stomach Neoplasms/diagnostic imaging , Stomach Neoplasms/pathology , Retrospective Studies , Tomography, Spiral Computed , Angiography
12.
Radiol Phys Technol ; 17(1): 207-218, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38127219

ABSTRACT

Solid-state detectors (SSDs) may be used along with a lead collimator for half-value layer (HVL) measurement using computed tomography (CT) with or without a tin filter. We aimed to compare HVL measurements obtained using three SSDs (AGMS-DM+ , X2 R/F sensor, and Black Piranha) with those obtained using the single-rotation technique with lead apertures (SRTLA). HVL measurements were performed using spiral CT at tube voltages of 70-140 kV without a tin filter and 100-140 kV (Sn 100-140 kV) with a tin filter in increments of 10 kV. For SRTLA, a 0.6-cc ionization chamber was suspended at the isocenter to measure the free-in-air kerma rate ( K ˙ air ) values. Five apertures were made on the gantry cover using lead sheets, and four aluminum plates were placed on these apertures. HVLs in SRTLA were obtained from K ˙ air decline curves. Subsequently, SSDs inserted into the lead collimator were placed on the gantry cover and used to measure HVLs. Maximum HVL differences of AGMS-DM+ , X2 R/F sensor, and Black Piranha with respect to SRTLA without/with a tin filter were - 0.09/0.6 (only two Sn 100-110 kV) mm, - 0.50/ - 0.6 mm, and - 0.17/(no data available) mm, respectively. These values were within the specification limit. SSDs inserted into the lead collimator could be used to measure HVL using spiral CT without a tin filter. HVLs could be measured with a tin filter using only the X2 R/F sensor, and further improvement of its calibration accuracy with respect to other SSDs is warranted.


Subject(s)
Tin , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Tomography, Spiral Computed , Phantoms, Imaging , Calibration
13.
J Comput Assist Tomogr ; 48(3): 491-497, 2024.
Article in English | MEDLINE | ID: mdl-38157266

ABSTRACT

OBJECTIVE: Salivary gland lesions show overlapping morphological findings and types of time/intensity curves. This research aimed to evaluate the role of 2-phase multislice spiral computed tomography (MSCT) texture analysis in differentiating between benign and malignant salivary gland lesions. METHODS: In this prospective study, MSCT was carried out on 90 patients. Each lesion was segmented on axial computed tomography (CT) images manually, and 33 texture features and morphological CT features were assessed. Logistic regression analysis was used to confirm predictors of malignancy ( P < 0.05 was considered to be statistically significant), followed by receiver operating characteristics analysis to assess the diagnostic performance. RESULTS: Univariate logistic regression analysis revealed that morphological CT features (shape, size, and invasion of adjacent tissues) and 17 CT texture parameters had significant differences between benign and malignant lesions ( P < 0.05). Multivariate binary logistic regression demonstrated that shape, invasion of adjacent tissues, entropy, and inverse difference moment were independent factors for malignant tumors. The diagnostic accuracy values of multivariate binary logistic models based on morphological parameters, CT texture features, and a combination of both were 87.8%, 90%, and 93.3%, respectively. CONCLUSIONS: Two-phase MSCT texture analysis was conducive to differentiating between malignant and benign neoplasms in the salivary gland, especially when combined with morphological CT features.


Subject(s)
Salivary Gland Neoplasms , Humans , Female , Male , Salivary Gland Neoplasms/diagnostic imaging , Salivary Gland Neoplasms/pathology , Middle Aged , Diagnosis, Differential , Adult , Aged , Prospective Studies , Young Adult , Adolescent , Radiographic Image Interpretation, Computer-Assisted/methods , Sensitivity and Specificity , Tomography, X-Ray Computed/methods , Aged, 80 and over , Reproducibility of Results , Multidetector Computed Tomography/methods , Tomography, Spiral Computed/methods , Salivary Glands/diagnostic imaging
14.
Rev. cuba. med ; 62(4)dic. 2023.
Article in Spanish | CUMED, LILACS | ID: biblio-1550894

ABSTRACT

Introducción: El neumoencéfalo (sinonimia: aerocele o neumatocele intracerebral), se define como la presencia de gas dentro de cualquiera de los compartimentos intracraneales (intraventricular, intraparenquimatosa, subaracnoidea, subdural y epidural). Objetivo: Describir los hallazgos clínicos, estudios complementarios, conducta terapéutica y evolución de un caso con neumoencéfalo como complicación de bloqueo regional epidural por radiculopatía lumbosacra. Presentación de caso: Se presentó un paciente masculino de 57 años de edad que comenzó con un cuadro súbito de desorientación, excitabilidad psicomotriz y convulsiones tónico-clónicas, a partir de una inyección epidural de metilprednisolona como método analgésico. Conclusiones: El caso presentado exhibió manifestaciones neurológicas inespecíficas, la aparición súbita posterior al proceder invasivo hizo sospechar en un evento neurológico agudo o fenómeno tromboembólico. Los estudios complementarios como la tomografía axial computarizada craneal simple, permitió su diagnóstico para tener una conducta consecuente. El manejo conservador del neumoencéfalo como complicación del uso de anestesia epidural, constituyó una conducta terapéutica eficaz y repercutió en la satisfactoria evolución del paciente(AU)


Introduction: Pneumocephalus (synonym: aerocele or intracerebral pneumatocele), is defined as the presence of gas within any of the intracranial compartments (intraventricular, intraparenchymal, subarachnoid, subdural and epidural). Objective: To describe the clinical findings, complementary studies, therapeutic conduct and evolution of a case with pneumocephalus as a complication of regional epidural block due to lumbosacral radiculopathy Case presentation: A 57-year-old male patient was presented who began with a sudden episode of disorientation, psychomotor excitability and tonic-clonic seizures, following an epidural injection of methylprednisolone as an analgesic method. Conclusions: The case presented exhibited non-specific neurological manifestations, the sudden appearance after the invasive procedure raised suspicion of an acute neurological event or thromboembolic phenomenon. Complementary studies such as simple cranial computed axial tomography, allowed its diagnosis to have a consistent conduct. The conservative management of pneumocephalus as a complication of the use of epidural anesthesia constituted an effective therapeutic approach and had an impact on the patient's satisfactory evolution(AU)


Subject(s)
Humans , Male , Middle Aged , Radiculopathy/complications , Methylprednisolone/therapeutic use , Pneumoencephalography/methods , Tomography, Spiral Computed/methods , Anesthesia, Epidural/methods
15.
Arch Esp Urol ; 76(8): 570-578, 2023 Oct.
Article in English | MEDLINE | ID: mdl-37960956

ABSTRACT

OBJECTIVE: The diagnostic value of multi-slice helical computed tomography (MSCT) reconstruction parameters combined with 3.0 T magnetic resonance (MR) in clear cell renal cell carcinoma (CCRCC) was analysed. METHODS: A total of 158 patients with renal tumours were selected in First Hospital in Zibo city from February 2018 to March 2023 for the retrospective study and divided into CCRCC and non-CCRCCs groups according to the final results of pathological diagnosis. MSCT detection and 3.0 T MR detection were performed in both groups for imaging manifestation analysis. The receiver operating characteristic (ROC) curve was used in analysing the clinical efficacy of each single and combined diagnosis. RESULTS: The results of pathological diagnosis showed 115 patients with CCRCC and 43 non-CCRCC patients, accounting for 72.78% and 27.22%, respectively. Patients with CCRCC had higher proportions of calcification, necrosis, cystic degeneration and more pseudocapsules than non-CCRCC patients (p < 0.05). Patients with CCRCC mainly showed peripheral and heterogeneous enhancement, whereas non-CCRCC patients mainly showed homogeneous enhancement, and the difference was significant (p < 0.05). The cortical phase, parenchymal phase and excretion stage had higher computed tomography (CT) values in the CCRCC group (p < 0.001), and no significant difference in the CT value of plain scan phase was found between the groups (p > 0.05). The CCRCC group had obviously higher apparent diffusion coefficient value and incidence of necrosis and cystic degeneration (p < 0.001), lower incidence of haemorrhage (p < 0.05) and distinctly higher cortical enhancement indexes in the cortical phase, parenchymal phase and delay period (p < 0.001). The ROC analysis showed that the area under the curve, specificity, sensitivity and 95% CI of combined detection were higher than those of each single detection. CONCLUSIONS: The combination of MSCT reconstruction parameters and 3.0 T MR has a certain diagnostic value for CCRCC. The combined diagnosis has higher area under the curve, specificity, sensitivity and 95% CI, which can provide effective reference for clinical diagnosis and treatment, with a certain clinical application value.


Subject(s)
Carcinoma, Renal Cell , Kidney Neoplasms , Humans , Carcinoma, Renal Cell/diagnosis , Retrospective Studies , Kidney Neoplasms/diagnosis , Tomography, Spiral Computed , Diagnosis, Differential , Magnetic Resonance Spectroscopy , Necrosis/diagnosis
16.
Med Phys ; 50(8): 4797-4808, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37283112

ABSTRACT

BACKGROUND: It is challenging to assess the accuracy of volume CT Dose Index (CTDIvol ) when the axial scan modes corresponding to a helical scan protocol are not available. An alternative approach was proposed to directly measure C T D I v o l H $CTDI_{vol}^H$ using helical acquisitions and relatively small differences (< 20%) from CTDIvol were observed. PURPOSE: To visually demonstrate the 3D dose distribution for both axial and helical CT acquisitions and quantitively compare C T D I v o l H $CTDI_{vol}^H$ and CTDIvol . METHODS: 3D dose distribution within the standard CTDI phantoms (16 and 32 cm diameter) from a single CT projection, Dp (x,y,z) was first generated using Monte Carlo simulation (GEANT4) with 9×108 photons per combination of tube voltage (80-140 kV), collimation width (1-8 cm), and z-axis location of the central ray of the x-ray beam, with a spatial resolution of 1 mm3 . These dose distributions from one single projection were analytically ensembled to simulate 3D dose volumes DA (x,y,z) and DH (x,y,z) for axial and helical scans, respectively, with different helical pitches (0.3-2) and scan lengths (100-150 mm). 2D planar dose distributions were obtained by integrating the inside 100 mm of the dose volumes. CTDIvol and C T D I v o l H $CTDI_{vol}^H\;$ were calculated using the planar dose data at corresponding pencil chamber locations and the percentage differences (PD) were reported. RESULTS: High spatial resolution 3D CT dose volumes were generated and visualized. PDs between C T D I v o l H $CTDI_{vol}^H$ and CTDIvol had strong dependency on scan length and peripheral chamber locations, with subtle dependency on collimation width and pitch. PDs were mostly within the range of ± 3% for a scan length of 150 mm with four peripheral chamber locations. CONCLUSIONS: With a scan length covering the entire phantom length, C T D I v o l H $CTDI_{vol}^H$ directly measured from helical scans can serve as an alternative to CTDIvol only if all four peripheral locations were measured.


Subject(s)
Cone-Beam Computed Tomography , Tomography, Spiral Computed , Computer Simulation , Monte Carlo Method , Phantoms, Imaging
17.
Zhonghua Kou Qiang Yi Xue Za Zhi ; 58(6): 554-560, 2023 Jun 09.
Article in Chinese | MEDLINE | ID: mdl-37272000

ABSTRACT

Objective: To explore an automatic landmarking method for anatomical landmarks in the three-dimensional (3D) data of the maxillary complex and preliminarily evaluate its reproducibility and accuracy. Methods: From June 2021 to December 2022, spiral CT data of 31 patients with relatively normal craniofacial morphology were selected from those who visited the Department of Oral and Maxillofacial Surgery, Peking University School and Hospital of Stomatology. The sample included 15 males and 16 females, with the age of (33.3±8.3) years. The maxillary complex was reconstructed in 3D using Mimics software, and the resulting 3D data of the maxillary complex was mesh-refined using Geomagic software. Two attending physicians and one associate chief physician manually landmarked the 31 maxillary complex datasets, determining 24 anatomical landmarks. The average values of the three expert landmarking results were used as the expert-defined landmarks. One case that conformed to the average 3D morphological characteristics of healthy individuals' craniofacial bones was selected as the template data, while the remaining 30 cases were used as target data. The open-source MeshMonk program (a non-rigid registration algorithm) was used to perform an initial alignment of the template and target data based on 4 landmarks (nasion, left and right zygomatic arch prominence, and anterior nasal spine). The template data was then deformed to the shape of the target data using a non-rigid registration algorithm, resulting in the deformed template data. Based on the unchanged index property of homonymous landmarks before and after deformation of the template data, the coordinates of each landmark in the deformed template data were automatically retrieved as the automatic landmarking coordinates of the homonymous landmarks in the target data, thus completing the automatic landmarking process. The automatic landmarking process for the 30 target data was repeated three times. The root-mean-square distance (RMSD) of the dense corresponding point pairs (approximately 25 000 pairs) between the deformed template data and the target data was calculated as the deformation error of the non-rigid registration algorithm, and the intra-class correlation coefficient (ICC) of the deformation error in the three repetitions was analyzed. The linear distances between the automatic landmarking results and the expert-defined landmarks for the 24 anatomical landmarks were calculated as the automatic landmarking errors, and the ICC values of the 3D coordinates in the three automatic landmarking repetitions were analyzed. Results: The average three-dimensional deviation (RMSD) between the deformed template data and the corresponding target data for the 30 cases was (0.70±0.09) mm, with an ICC value of 1.00 for the deformation error in the three repetitions of the non-rigid registration algorithm. The average automatic landmarking error for the 24 anatomical landmarks was (1.86±0.30) mm, with the smallest error at the anterior nasal spine (0.65±0.24) mm and the largest error at the left oribital (3.27±2.28) mm. The ICC values for the 3D coordinates in the three automatic landmarking repetitions were all 1.00. Conclusions: This study established an automatic landmarking method for three-dimensional data of the maxillary complex based on a non-rigid registration algorithm. The accuracy and repeatability of this method for landmarking normal maxillary complex 3D data were relatively good.


Subject(s)
Algorithms , Imaging, Three-Dimensional , Male , Female , Humans , Adult , Imaging, Three-Dimensional/methods , Reproducibility of Results , Software , Tomography, Spiral Computed , Anatomic Landmarks/anatomy & histology
18.
Radiat Prot Dosimetry ; 199(12): 1295-1300, 2023 Jul 21.
Article in English | MEDLINE | ID: mdl-37337642

ABSTRACT

We investigated the effect of electrocardiographic (ECG) mA-modulation of ECG-gated scans of computed tomography (CTA) on radiation dose and image noise at high heart rates (HR) above 100 bpm between helical pitches (HP) 0.16 and 0.24. ECG mA-modulation range during ECG-gated CTA is 50-100 mA, the phase setting is 40-60% and the scan range is 90 mm for clinical data during HR for 90, 120 and 150 bpm. Radiation dose and image noise in Housfield units are measured for CT equipment during HR for 90, 120 and 150 bpm between HP 0.16 and 0.24. ECG mA-modulation, dose reduction ratio for HR 90, 120 and 150 bpm are 19.1, 13.4 and 8.7% at HP 0.16 and 17.1, 13.3 and 7.7% at HP 0.24, respectively. No significant differences were observed in image noise between both HP. Dose reductions of 8-24% are achieved with ECG mA-modulation during ECG-gated CCTA scan, which is beneficial even in high HR more than 100 bpm.


Subject(s)
Pediatrics , Tomography, Spiral Computed , Humans , Child , Coronary Angiography/methods , Tomography, Spiral Computed/methods , Heart Rate , Radiation Dosage , Electrocardiography , Tomography, X-Ray Computed
19.
Cancer Med ; 12(11): 12050-12064, 2023 06.
Article in English | MEDLINE | ID: mdl-37248730

ABSTRACT

BACKGROUND: Many people were found with pulmonary nodules during physical examinations. It is of great practical significance to discriminate benign and malignant nodules by using data mining technology. METHODS: The subjects' demographic data, baseline examination results, and annual follow-up low-dose spiral computerized tomography (LDCT) results were recorded. The findings from annual physical examinations of positive nodules, including highly suspicious nodules and clinically tentative benign nodules, was analyzed. The extreme gradient boosting (XGBoost) model was constructed and the Grid Search CV method was used to select the super parameters. External unit data were used as an external validation set to evaluate the generalization performance of the model. RESULTS: A total of 135,503 physical examinees were enrolled. Baseline testing found that 27,636 (20.40%) participants had clinically tentative benign nodules and 611 (0.45%) participants had highly suspicious nodules. The proportion of highly suspicious nodules in participants with negative baseline was about 0.12%-0.46%, which was lower than the baseline level except the follow-up of >5 years. In the 27,636 participants with clinically tentative benign nodules, only in the first year of LDCT re-examination was the proportion of highly suspicious nodules (1.40%) significantly greater than that of baseline screening (0.45%) (p < 0.001), and the proportion of highly suspicious nodules was not different between the baseline screening and other follow-up years (p > 0.05). Furthermore, 322 cases with benign nodules and 196 patients with malignant nodules confirmed by surgery and pathology were compared. A model and the top 15 most important clinical variables were determined by XGBoost algorithm. The area under the curve (AUC) of the model was 0.76 [95% CI: 0.67-0.84], and the accuracy was 0.75. The sensitivity and specificity of the model under this threshold were 0.78 and 0.73, respectively. In the validation of model using external data, the AUC was 0.87 and the accuracy was 0.80. The sensitivity and specificity were 0.83 and 0.77, respectively. CONCLUSIONS: It is important that pulmonary nodules could be more accurately identified at the first LDCT examination. A model with 15 variables which are routinely measured in the clinic could be helpful to distinguish benign and malignant nodules. It could help the radiological team issue a more accurate report; and it may guide the clinical team regarding LDCT follow-up.


Subject(s)
Lung Neoplasms , Multiple Pulmonary Nodules , Humans , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/pathology , Multiple Pulmonary Nodules/diagnostic imaging , Multiple Pulmonary Nodules/pathology , Tomography, Spiral Computed/methods , Sensitivity and Specificity , Machine Learning , Early Detection of Cancer
20.
J Comput Assist Tomogr ; 47(3): 424-428, 2023.
Article in English | MEDLINE | ID: mdl-37185006

ABSTRACT

BACKGROUND: Foreign body aspiration (FBA) in childhood is a life-threatening condition that necessitates prompt management to prevent devastating complications. Different imaging methods are used in the diagnosis of FBA. OBJECTIVE: The aim of this study was to compare the diagnostic value and dose of microsievert wide-volume computed tomography (µSv-WV-CT) with multidetector computed tomography using an automatic exposure control system (MDCT-AEC) in children with FBA. MATERIAL AND METHODS: In this single-center cross-sectional study, 102 cases diagnosed with FBA between September 2013 and September 2021 were retrospectively evaluated. The patients were divided into 2 groups according to the diagnostic modality used: group A, µSv-WV-CT (2016-2021) and group B, MDCT-AEC (2013-2021). The diagnostic performance and radiation dose of the 2 groups were statistically compared. RESULTS: The diagnostic performance (sensitivity, specificity, positive predictive value, negative predictive value, and accuracy) of the 2 groups was similar. The mean effective radiation dose of group A was 34.89 ± 0.01 µSv, which was significantly lower than that of group B (179.75 ± 114.88 µSv) ( P < 0.001). CONCLUSION: In children with suspected FBA, µSv-WV-CT at a lower radiation dose had similar diagnostic performance to MDCT-AEC.


Subject(s)
Foreign Bodies , Tomography, Spiral Computed , Humans , Child , Retrospective Studies , Cross-Sectional Studies , Multidetector Computed Tomography , Foreign Bodies/diagnostic imaging , Radiation Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...