Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.173
Filter
1.
J Acoust Soc Am ; 155(4): 2769-2785, 2024 Apr 01.
Article in English | MEDLINE | ID: mdl-38662609

ABSTRACT

Assuming plane waves, ear-canal acoustic quantities, collectively known as wideband acoustic immittance (WAI), are frequently used in research and in the clinic to assess the conductive status of the middle ear. Secondary applications include compensating for the ear-canal acoustics when delivering stimuli to the ear and measuring otoacoustic emissions. However, the ear canal is inherently non-uniform and terminated at an oblique angle by the conical-shaped tympanic membrane (TM), thus potentially confounding the ability of WAI quantities in characterizing the middle-ear status. This paper studies the isolated possible confounding effects of TM orientation and shape on characterizing the middle ear using WAI in human ears. That is, the non-uniform geometry of the ear canal is not considered except for that resulting from the TM orientation and shape. This is achieved using finite-element models of uniform ear canals terminated by both lumped-element and finite-element middle-ear models. In addition, the effects on stimulation and reverse-transmission quantities are investigated, including the physical significance of quantities seeking to approximate the sound pressure at the TM. The results show a relatively small effect of the TM orientation on WAI quantities, except for a distinct delay above 10 kHz, further affecting some stimulation and reverse-transmission quantities.


Subject(s)
Ear Canal , Finite Element Analysis , Pressure , Tympanic Membrane , Humans , Tympanic Membrane/physiology , Ear Canal/physiology , Sound , Acoustics , Acoustic Stimulation , Computer Simulation , Models, Anatomic , Otoacoustic Emissions, Spontaneous/physiology , Ear, Middle/physiology , Acoustic Impedance Tests/methods
2.
Hear Res ; 444: 108970, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38367458

ABSTRACT

The tympanic middle ear is important for anuran hearing on land. However, many species have partly or entirely lost their tympanic apparatus. Previous studies have compared hearing sensitivities in species that possess and lack tympanic membranes capable of sound production and acoustic communication. However, little is known about how these hearing abilities are comparable to those of mutant species. Here, we compared the eardrum and middle ear anatomies of two sympatric sibling species from a noisy stream habitat, namely the "non-vocal" Hainan torrent frog (Amolops hainanensis) and the "vocal" little torrent frog (Amolops torrentis), the latter of which is capable of acoustic communication. Our results showed that the relative (to head size) eardrum diameter of A. hainanensis was smaller than that of A. torrentis, although the absolute size was not smaller. Unlike A. torrentis, the tympanic membrane area of A. hainanensis was not clearly differentiated from the surrounding skin. The middle ear, however, was well-developed in both species. We measured the auditory brainstem responses (ABRs) of A. hainanensis and compared the ABR thresholds and latencies to those previously obtained for A. torrentis. Our results suggested that these two species exhibited significant differences in hearing sensitivity. A. hainanensis (smaller relative eardrum, nonvocal) had higher ABR thresholds and longer initial response times than A. torrentis (larger relative eardrum, vocal) at lower frequencies. Neurophysiological responses from the brain were obtained for tone pips between 800 Hz and 7,000 Hz, with peak sensitivities found at 3,000 Hz (73 dB SPL) for A. hainanensis, and at 1,800 Hz (61 dB SPL) for A. torrentis. Our results suggest that the non-vocal A. hainanensis has lower hearing sensitivity than its vocal sister species (i.e., A. torrentis), which may be related to differences in tympanic or inner ear structure and morphology.


Subject(s)
Ear, Middle , Tympanic Membrane , Animals , Tympanic Membrane/physiology , Auditory Threshold/physiology , Ear, Middle/physiology , Hearing/physiology , Anura
3.
J Insect Physiol ; 152: 104595, 2024 01.
Article in English | MEDLINE | ID: mdl-38052320

ABSTRACT

Insect cuticle is an evolutionary-malleable exoskeleton that has specialised for various functions. Insects that detect the pressure component of sound bear specialised sound-capturing tympani evolved from cuticular thinning. Whilst the outer layer of insect cuticle is composed of non-living chitin, its mechanical properties change during development and aging. Here, we measured the displacements of the tympanum of the desert Locust, Schistocerca gregaria, to understand biomechanical changes as a function of age and noise-exposure. We found that the stiffness of the tympanum decreases within 12 h of noise-exposure and increases as a function of age, independent of noise-exposure. Noise-induced changes were dynamic with an increased tympanum displacement to sound within 12 h post noise-exposure. Within 24 h, however, the tone-evoked displacement of the tympanum decreased below that of control Locusts. After 48 h, the tone-evoked displacement of the tympanum was not significantly different to Locusts not exposed to noise. Tympanal displacements reduced predictably with age and repeatably noise-exposed Locusts (every three days) did not differ from their non-noise-exposed counterparts. Changes in the biomechanics of the tympanum may explain an age-dependent decrease in auditory detection in tympanal insects.


Subject(s)
Ear, Middle , Grasshoppers , Animals , Ear, Middle/physiology , Tympanic Membrane/physiology , Grasshoppers/physiology , Sound , Biomechanical Phenomena
4.
Anat Rec (Hoboken) ; 307(1): 198-207, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37259899

ABSTRACT

The different velocities of sound (pressure waves) in air and water make auditory source localization a challenge for amphibious animals. The American alligator (Alligator mississippiensis) has an extracolumellar cartilage that abuts the deep surface of the tympanic membrane, and then expands in size beyond the caudal margin of the tympanum. This extracolumellar expansion is the insertion site for two antagonistic skeletal muscles, the tensor tympani, and the depressor tympani. These muscles function to modulate the tension in the tympanic membrane, presumably as part of the well-developed submergence reflex of Alligator. All crocodilians, including Alligator, have internally coupled ears in which paratympanic sinuses connect the contralateral middle ear cavities. The temporal performance of internally coupled ears is determined, in part, by the tension of the tympanic membrane. Switching between a "tensed" and "relaxed" tympanic membrane may allow Alligator to compensate for the increased velocity of sound underwater and, in this way, use a single auditory map for sound localization in two very different physical environments.


Subject(s)
Alligators and Crocodiles , Animals , Hearing/physiology , Ear, Middle , Tympanic Membrane/physiology , Head
5.
Acta Otolaryngol ; 143(7): 558-562, 2023.
Article in English | MEDLINE | ID: mdl-37366291

ABSTRACT

BACKGROUND: Current clinical tests for middle ear (ME) injuries and related conductive hearing loss (CHL) are lengthy and costly, lacking the ability to noninvasively evaluate both structure and function in real time. Optical coherence tomography (OCT) provides both, but its application to the audiological clinic is currently limited. OBJECTIVE: Adapt and use a commercial Spectral-Domain OCT (SD-OCT) to evaluate anatomy and sound-evoked vibrations of the tympanic membrane (TM) and ossicles in the human ME. MATERIALS AND METHODS: SD-OCT was used to capture high-resolution three-dimensional (3D) ME images and measure sound-induced vibrations of the TM and ossicles in fresh human temporal bones. RESULTS: The 3D images provided thickness maps of the TM. The system was, with some software adaptations, also capable of phase-sensitive vibrometry. Measurements revealed several modes of TM vibration that became more complex with frequency. Vibrations were also measured from the incus, through the TM. This quantified ME sound transmission, which is the essential measure to assess CHL. CONCLUSION AND SIGNIFICANCE: We adapted a commercial SD-OCT to visualize the anatomy and function of the human ME. OCT has the potential to revolutionize point-of-care assessment of ME disruptions that lead to CHL which are otherwise indistinguishable via otoscopy.


Subject(s)
Ear Diseases , Tomography, Optical Coherence , Humans , Tomography, Optical Coherence/methods , Ear, Middle/diagnostic imaging , Ear, Middle/physiology , Tympanic Membrane/diagnostic imaging , Tympanic Membrane/physiology , Sound , Vibration , Hearing Loss, Conductive
6.
Acta Neurochir (Wien) ; 165(8): 2227-2235, 2023 08.
Article in English | MEDLINE | ID: mdl-37369772

ABSTRACT

BACKGROUND: The observation of tympanic membrane displacement (TMD) opens up the possibility of indirect intracranial pressure (ICP) estimation. In this study, we applied a phase-based video motion magnification (VMM) algorithm to reveal spontaneous pulse TMD waveforms (spTMD) and compare them with invasively measured ICP in patients with intracranial pathologies. METHODS: Nine adults (six traumatic brain injury and three aneurysmal subarachnoid haemorrhage; median age 44 (29-53) years admitted to the intensive care unit of Wroclaw Medical University between October 2021 and October 2022 with implanted ICP sensors were included in this retrospective study. Video recordings of the tympanic membrane were performed using a portable otoscope with a video camera and analysed by a custom-written VMM algorithm. ICP was monitored using intraparenchymal sensors and arterial blood pressure (ABP) was measured in the radial arterial lines. ICP, ABP, and spTMD videos were captured simultaneously. The pulse amplitudes of ICP (Amp_ICP), ABP (Amp_ABP) and spTMD (Amp_spTMD) were estimated using fast Fourier transform within the heart rate (HR)-related frequency range. RESULTS: Amp_spTMD was significantly correlated with mean ICP (rS = 0.73; p = 0.025) and with Amp_ICP (rS = 0.88; p = 0.002). Age was not a significant moderator of this association. There were no significant relationships between Amp_spTMD and either mean ABP, HR, or Amp_ABP. CONCLUSIONS: The study suggests that Amp_spTMD increases with the increase in mean ICP and Amp_ICP. Estimation of Amp_spTMD using the VMM algorithm has the potential to allow for non-invasive detection of the risk of elevated ICP; however, further investigation in a larger group of patients is required.


Subject(s)
Intracranial Hypertension , Intracranial Pressure , Adult , Humans , Middle Aged , Retrospective Studies , Intracranial Pressure/physiology , Tympanic Membrane/physiology , Arterial Pressure , Brain , Cerebrovascular Circulation/physiology , Blood Pressure/physiology
7.
Sci Rep ; 13(1): 7329, 2023 05 05.
Article in English | MEDLINE | ID: mdl-37147426

ABSTRACT

For over 40 years, finite-element models of the mechanics of the middle ear have been mostly deterministic in nature. Deterministic models do not take into account the effects of inter-individual variabilities on middle-ear parameters. We present a stochastic finite-element model of the human middle ear that uses variability in the model parameters to investigate the uncertainty in the model outputs (umbo, stapes, and tympanic-membrane displacements). We demonstrate: (1) uncertainties in the model parameters can be magnified by more than three times in the umbo and stapes footplate responses at frequencies above 2 kHz; (2) middle-ear models are biased and they distort the output distributions; and (3) with increased frequency, the highly-uncertain regions spatially spread out on the tympanic membrane surface. Our results assert that we should be mindful when using deterministic finite-element middle-ear models for critical tasks such as novel device developments and diagnosis.


Subject(s)
Ear, Middle , Models, Biological , Humans , Finite Element Analysis , Ear, Middle/physiology , Tympanic Membrane/physiology , Stapes/physiology
8.
J Assoc Res Otolaryngol ; 24(3): 339-363, 2023 06.
Article in English | MEDLINE | ID: mdl-37165211

ABSTRACT

PURPOSE: Optical coherence tomography (OCT) is an emerging imaging modality which is non-invasive, can be employed in vivo, and can record both anatomy and vibrations. The purpose here is to explore the application of finite-element (FE) modelling to OCT data. METHODS: We recorded vibrations for three human cadaver middle ears using OCT. We also have X-ray microCT images from the same ears. Three FE models were built based on geometries obtained from the microCT images. The material properties and boundary conditions of the models were obtained from previously reported studies. RESULTS: Tympanic-membrane (TM) vibration patterns were computed for the three models and compared with the patterns measured using OCT. Frequency responses were also computed for all three models for several locations in the middle ear and compared with the OCT displacements and with the literature. The three models were compared with each other in terms of geometry and function. Parameter sensitivity analyses were done and the results were compared among the models and with the literature. The simulated TM displacement patterns are qualitatively similar to the OCT results. The simulated displacements are closer to the OCT results for 500 Hz and 1 kHz but the differences are greater at 2 kHz. CONCLUSION: This study provides an initial look at the combined use of OCT measurements and FE modelling based on subject-specific anatomy. The geometries and parameters of the existing FE models could be modified for individual patients in the future to help identify abnormalities in the middle ear.


Subject(s)
Ear, Middle , Tomography, Optical Coherence , Humans , X-Ray Microtomography , Tomography, Optical Coherence/methods , Ear, Middle/diagnostic imaging , Ear, Middle/physiology , Tympanic Membrane/physiology , Vibration , Finite Element Analysis
9.
Comput Methods Programs Biomed ; 236: 107540, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37086583

ABSTRACT

BACKGROUND AND OBJECTIVE: The fixation of ligament and tendon of the middle ear often occurs after chronic otitis media surgery. However, there are relatively few studies on the effect of ligament and tendon on sound transmission in the human middle ear. Here, the finite element model and lumped parameter model are used to study the effect of ligament and tendon fixation and detachment on sound transmission in human ear. METHODS: In this paper, the finite element model including the external auditory canal, middle ear and simplified inner ear is used to calculate and compare the middle ear frequency response of the normal and tympanosclerosis under pure tone stimulation. In addition, the lumped parametric model is taken into account to illustrate the effect of ligament and tendon stiffness on the human ear transmission system. RESULTS: The results indicate that the motion of the tympanic membrane and stapes is reduced by ligament and tendon fixation. Although ligament and tendon detachment have a limited effect in the piston-motion direction, the stability of motion in the plane perpendicular to the piston-motion direction is significantly reduced. Most significantly, the ligament and tendon fixation cause a hearing effect of about 18 dB, which is greater in the plane perpendicular to the piston-motion direction after ligament and tendon detachment than in the piston-motion direction. CONCLUSIONS: In this study, the calculation accuracy of the lumped parameter and the finite element model is studied, and the effect of ligament and tendon on hearing loss is further explored through the finite element model with high calculation accuracy, which is helpful to understand the role of ligament and tendon in the sound transmission mechanism of the human middle ear. The study of ligament and tendon on conductive hearing loss provides a reference for clinical treatment of tympanosclerosis.


Subject(s)
Ear, Middle , Hearing Loss, Conductive , Humans , Finite Element Analysis , Ear, Middle/physiology , Tympanic Membrane/physiology , Ligaments , Tendons
10.
Biomech Model Mechanobiol ; 22(3): 1003-1018, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36881185

ABSTRACT

Damping plays an important role in the middle ear (ME) sound transmission system. However, how to mechanically characterize the damping of ME soft tissues and the role of damping in ME sound transmission have not yet reached a consensus. In this paper, a finite element (FE) model of the partial external and ME of the human ear, considering both Rayleigh damping and viscoelastic damping for different soft tissues, is developed to quantitatively investigate the damping in soft tissues effects on the wide-frequency response of the ME sound transmission system. The model-derived results can capture the high-frequency (above 2 kHz) fluctuations and obtain the 0.9 kHz resonant frequency (RF) of the stapes velocity transfer function (SVTF) response. The results show that the damping of pars tensa (PT), stapedial annular ligament (SAL) and incudostapedial joints (ISJ) can help smooth the broadband response of the umbo and stapes footplate (SFP). It is found that, between 1 and 8 kHz, the damping of the PT increases the magnitude and phase delay of the SVTF above 2 kHz while the damping of the ISJ can avoid excessive phase delay of the SVTF, which is important in maintaining the synchronization in high-frequency vibration but has not been revealed before. Below 1 kHz, the damping of the SAL plays a more important role, and it can decrease the magnitude but increases the phase delay of the SVTF. This study has implications for a better understanding of the mechanism of ME sound transmission.


Subject(s)
Ear, Middle , Sound , Humans , Ear, Middle/physiology , Stapes/physiology , Vibration , Tympanic Membrane/physiology
11.
Hear Res ; 430: 108721, 2023 03 15.
Article in English | MEDLINE | ID: mdl-36821982

ABSTRACT

The three-bone flexible ossicular chain in mammals may allow independent alterations of middle-ear (ME) sound transmission via its two attached muscles, for both acoustic and non-acoustic stimuli. The tensor tympani (TT) muscle, which has its insertion on the malleus neck, is thought to increase tension of the tympanic membrane (TM). The stapedius (St) muscle, which has its insertion on the stapes posterior crus, is known to stiffen the stapes annular ligament. We produced ME changes in human cadaveric temporal bones by statically pulling on the TT and St muscles. The 3D static TM shape and sound-induced umbo motions from 20 Hz to 10 kHz were measured with optical coherence tomography (OCT); stapes motion was measured using laser-Doppler vibrometry (LDV). TT pulls made the TM shape more conical and moved the umbo medially, while St pulls moved the umbo laterally. In response to sound below about 1 kHz, stapes-velocity magnitudes generally decreased by about 10 dB due to TT pulls and 5 dB due to St pulls. In the 250 to 500 Hz region, the group delay calculated from stapes-velocity phase showed a decrease in transmission delay of about 150 µs by TT pulls and 60 µs by St pulls. Our interpretation of these results is that ME-muscle activity may provide a way of mechanically changing interaural time- and level-difference cues. These effects could help the brain align head-centered auditory and ocular-centered visual representations of the environment.


Subject(s)
Ear, Middle , Tympanic Membrane , Animals , Humans , Tympanic Membrane/physiology , Ear, Middle/diagnostic imaging , Ear, Middle/physiology , Stapes/physiology , Sound , Tensor Tympani , Temporal Bone/diagnostic imaging , Temporal Bone/physiology , Vibration , Mammals
12.
Acta Biomater ; 159: 63-73, 2023 03 15.
Article in English | MEDLINE | ID: mdl-36708849

ABSTRACT

A methodology for the development of a finite element numerical model of the tympanic membrane (TM) based on experiments carried out in the time domain on a cadaveric human temporal bone is presented. Using a high-speed digital holographic (HDH) system, acoustically-induced transient displacements of the TM surface are obtained. The procedure is capable to generate and validate the finite element model of the TM by numerical and experimental data correlation. Reverse engineering approach is used to identify key material parameters that define the mechanical response of the TM. Finally, modal numerical simulations of the specimen are performed. Results show the feasibility of the methodology to obtain an accurate model of a specific specimen and to help interpret its behaviour with additional numerical simulations. STATEMENT OF SIGNIFICANCE: Improving knowledge of the dynamic behavior of the tympanic membrane is key to understanding the sound transmission system in human hearing and advance in the treatment of its pathologies. Recently we acquired a new tool to carry out experiments in transient regime by means of digital laser holography, capable of providing a large amount of information in a controlled transient test. In this work, these data are used to develop a methodology that generates a numerical model of the tympanic membrane based on numerical-experimental correlations. It is important to be able to develop models that fit specific patients. In this work, additional modal simulations are also presented that, in addition to validating the results, provide more information on the specimen.


Subject(s)
Holography , Tympanic Membrane , Humans , Tympanic Membrane/physiology , Holography/methods , Vibration , Sound , Finite Element Analysis
13.
J Assoc Res Otolaryngol ; 23(6): 739-750, 2022 12.
Article in English | MEDLINE | ID: mdl-36100816

ABSTRACT

Tympanometry provides an objective measurement of the status of the middle ear. During tympanometry, the ear-canal pressure is varied, while the response of the ear to sound pressure is measured. The effects of the pressure on the mechanics of the middle ear are not well understood. This study is a continuation of our previous work in which the vibration response of the gerbil eardrum was measured in vivo under quasi-static pressure steps. In this study, we delivered a continuous pressure sweep to the middle ear and measured the vibration response at four locations for six gerbils. Vibrations were recorded using a single-point laser Doppler vibrometer and glass-coated reflective beads (diameter ~ 40 µm) at the umbo and on the mid-manubrium, posterior pars tensa and anterior pars tensa.The vibration magnitudes were similar to those in the previous step-wise pressurization experiments. Most gerbils showed repeatability within less than 10 dB for consecutive cycles. As described in the previous study, as the frequency was increased at ambient pressure, the vibration magnitude on the manubrium increased slightly to a broad peak (referred to as R1) and then decreased until a small peak appeared (referred to as R2), followed by multiple peaks and troughs as the magnitude decreased further. The low-frequency vibration magnitude (at 1 kHz) decreased monotonically as the pressure became more negative except for a dip (about 500 Pa wide) that occurred between - 700 and - 1800 Pa. The lowest overall magnitude was recorded in the dip at mid-manubrium. The vibration magnitudes also decreased as the middle-ear pressure was made more positive and were larger than those at negative pressures. R1 was only visible at negative and small positive middle-ear pressures, while R2 was visible for both positive and negative pressures. R2 split into multiple branches after the middle-ear pressure became slightly positive. No magnitude dip was visible for positive middle-ear pressures.The low-frequency vibration magnitudes at negative middle-ear pressures on the pars tensa were higher than those on the manubrium. R1 was not visible for large negative middle-ear pressures on the pars tensa. R2 appeared as a multi-peak feature on the pars tensa as well, and a higher-frequency branch on the posterior pars tensa appeared as a trough on the anterior pars tensa. The magnitude dip was not present on the pars tensa. The largest overall magnitude was recorded at the R2 peak on the posterior pars tensa.The results of this study expand on the findings of the step-wise pressurization experiments and provide further insight into the evolution of the vibration response of the eardrum under quasi-static pressures.


Subject(s)
Tympanic Membrane , Vibration , Animals , Tympanic Membrane/physiology , Gerbillinae , Ear, Middle/physiology , Sound
14.
Adv Healthc Mater ; 11(20): e2201471, 2022 10.
Article in English | MEDLINE | ID: mdl-35899802

ABSTRACT

Eardrum perforation and associated hearing loss is a global health problem. Grafting perforated eardrum with autologous tissues in clinic can restore low-frequency hearing but often leaves poor recovery of high-frequency hearing. In this study, the potential of incorporating a thin multilayered graphene membrane (MGM) into the eardrum for broadband hearing recovery in rats is examined. The MGM shows good biocompatibility and biostability to promote the growth of eardrum cells in a regulated manner with little sign of tissue rejection and inflammatory response. After three weeks of implantation, the MGM is found to be encapsulated by a thin layer of newly grown tissue on both sides without a significant folded overgrowth that is often seen in natural healing. The perforation is well sealed, and broadband hearing recovery (1-32 kHz) is enabled and maintained for at least 2 months. Mechanical simulations show that the high elastic modulus of MGM and thin thickness of the reconstructed eardrum play a critical role in the recovery of high-frequency hearing. This work demonstrates the promise of the use of MGM as a functional graft for perforated eardrum to recover hearing in the broadband frequency region and suggests a new acoustics-related medical application for graphene-related 2D materials.


Subject(s)
Graphite , Tympanic Membrane Perforation , Animals , Rats , Tympanic Membrane/physiology , Hearing/physiology , Acoustics
15.
J Acoust Soc Am ; 151(3): 2043, 2022 03.
Article in English | MEDLINE | ID: mdl-35364966

ABSTRACT

Many experimental data on the human middle ear (ME) mechanics and dynamics can be found in the literature. Nevertheless, discussions about the uncertainties of these data are scarce. The present study compiles experimental data on the mechanical properties of the human ME. The summary statistics of mean and standard deviation of the data were collected and the coefficients of variation were computed and pooled. Moreover, the linear correlation and distribution were assessed for the ossicles' mass. Results show that, generally, the uncertainties of the stiffness properties of the tympanic membrane, ligaments, and tendons are larger than the uncertainties of the ossicles' mass. In addition, the uncertainties of the ME response vary across frequency. The vibration measures, such as the stapes' velocity normalized by the sound pressure at the tympanic membrane, are more uncertain than ME input impedance and reflectance. It is expected that the results presented in this study will provide the basis for the development of probabilistic models of the human ME.


Subject(s)
Ear, Middle , Tympanic Membrane , Ear, Middle/physiology , Humans , Sound , Stapes , Tympanic Membrane/physiology , Vibration
16.
Sci Rep ; 12(1): 984, 2022 01 19.
Article in English | MEDLINE | ID: mdl-35046419

ABSTRACT

Drug treatments for middle ear diseases are currently delivered systemically, or locally after opening the impermeable tympanic membrane (TM). We previously used bacteriophage display to discover novel peptides that are actively transported across the intact TM, with a variety of transport rates. Peptide structures were analyzed for evidence regarding the mechanism for this unexpected transport, which was then tested by the application of chemical inhibitors. Primary sequences indicated that trans-TM peptides share one of two amino acid motifs. Secondary structures revealed that linear configurations associate with higher transport rates than coiled structures. Tertiary analysis indicated that the shared sequence motifs are prominently displayed at the free ends of rapidly transported peptide phage. The shared motifs were evaluated for similarity to known motifs. The highest probability matches were for protein motifs involved in transmembrane transport and exosomes. Overall, structural findings suggest that the shared motifs represent binding sequences. They also implicate transcytosis, a polarized cell transport mechanism consisting of endocytosis, transcellular transport, and exocytosis. Inhibitor studies indicated that macropinocytosis, retrograde transport through Golgi and exocytosis participate in transport across the TM, consistent with transcytosis. This process can be harnessed to noninvasively deliver therapeutics to the middle ear.


Subject(s)
Otitis Media/drug therapy , Peptides/metabolism , Transcytosis/physiology , Tympanic Membrane/physiology , Amino Acid Motifs , Animals , Bacteriophages , Ear, Middle , Endocytosis , Haemophilus influenzae , Peptides/chemistry , Rats, Sprague-Dawley
17.
Sci Rep ; 11(1): 21957, 2021 11 09.
Article in English | MEDLINE | ID: mdl-34753976

ABSTRACT

Neurological conditions such as traumatic brain injury (TBI) and hydrocephalus may lead to intracranial pressure (ICP) elevation. Current diagnosis methods rely on direct pressure measurement, while CT, MRI and other expensive imaging may be used. However, these invasive or expensive testing methods are often delayed because symptoms of elevated ICP are non-specific. Invasive methods, such as intraventricular catheter, subdural screw, epidural sensor, lumbar puncture, are associated with an increased risk of infection and hemorrhage. On the other hand, noninvasive, low-cost, accurate methods of ICP monitoring can help avoid risks and reduce costs while expediting diagnosis and treatment. The current study proposes and evaluates a novel method for noninvasive ICP monitoring using tympanic membrane pulsation (TMp). These signals are believed to be transmitted from ICP to the auditory system through the cochlear aqueduct. Fifteen healthy subjects were recruited and TMp signals were acquired noninvasively while the subjects performed maneuvers that are known to change ICP. A custom made system utilizing a stethoscope headset and a pressure transducer was used to perform these measurements. Maneuvers included head-up-tilt, head-down-tilt and hyperventilation. When elevated ICP was induced, significant TMp waveform morphological changes were observed in each subject (p < 0.01). These changes include certain waveform slopes and high frequency wave features. The observed changes were reversed by the maneuvers that decreased ICP (p < .01). The study results suggest that TMp waveform measurement and analysis may offer an inexpensive, noninvasive, accurate tool for detection and monitoring of ICP elevations. Further studies are warranted to validate this technique in patients with pathologically elevated ICP.


Subject(s)
Intracranial Hypertension/diagnostic imaging , Tympanic Membrane/physiology , Adult , Brain Injuries, Traumatic/complications , Female , Humans , Intracranial Hypertension/etiology , Magnetic Resonance Imaging , Male , Monitoring, Physiologic/methods , Young Adult
18.
Proc Natl Acad Sci U S A ; 118(39)2021 09 28.
Article in English | MEDLINE | ID: mdl-34551976

ABSTRACT

Bushcrickets (katydids) rely on only 20 to 120 sensory units located in their forelegs to sense sound. Situated in tiny hearing organs less than 1 mm long (40× shorter than the human cochlea), they cover a wide frequency range from 1 kHz up to ultrasounds, in tonotopic order. The underlying mechanisms of this miniaturized frequency-place map are unknown. Sensory dendrites in the hearing organ (crista acustica [CA]) are hypothesized to stretch, thereby driving mechanostransduction and frequency tuning. However, this has not been experimentally confirmed. Using optical coherence tomography (OCT) vibrometry, we measured the relative motion of structures within and adjacent to the CA of the bushcricket Mecopoda elongata We found different modes of nanovibration in the CA that have not been previously described. The two tympana and the adjacent septum of the foreleg that enclose the CA were recorded simultaneously, revealing an antiphasic lever motion strikingly reminiscent of vertebrate middle ears. Over the entire length of the CA, we were able to separate and compare vibrations of the top (cap cells) and base (dorsal wall) of the sensory tissue. The tuning of these two structures, only 15 to 60 µm (micrometer) apart, differed systematically in sharpness and best frequency, revealing a tuned periodic deformation of the CA. The relative motion of the two structures, a potential drive of transduction, demonstrated sharper tuning than either of them. The micromechanical complexity indicates that the bushcricket ear invokes multiple degrees of freedom to achieve frequency separation with a limited number of sensory cells.


Subject(s)
Ear, Middle/physiology , Gryllidae/physiology , Hearing , Sound , Tympanic Membrane/physiology , Vibration , Acoustic Stimulation , Animals
19.
Proc Natl Acad Sci U S A ; 118(10)2021 03 09.
Article in English | MEDLINE | ID: mdl-33658360

ABSTRACT

Located in the forelegs, katydid ears are unique among arthropods in having outer, middle, and inner components, analogous to the mammalian ear. Unlike mammals, sound is received externally via two tympanic membranes in each ear and internally via a narrow ear canal (EC) derived from the respiratory tracheal system. Inside the EC, sound travels slower than in free air, causing temporal and pressure differences between external and internal inputs. The delay was suspected to arise as a consequence of the narrowing EC geometry. If true, a reduction in sound velocity should persist independently of the gas composition in the EC (e.g., air, [Formula: see text]). Integrating laser Doppler vibrometry, microcomputed tomography, and numerical analysis on precise three-dimensional geometries of each experimental animal EC, we demonstrate that the narrowing radius of the EC is the main factor reducing sound velocity. Both experimental and numerical data also show that sound velocity is reduced further when excess [Formula: see text] fills the EC. Likewise, the EC bifurcates at the tympanal level (one branch for each tympanic membrane), creating two additional narrow internal sound paths and imposing different sound velocities for each tympanic membrane. Therefore, external and internal inputs total to four sound paths for each ear (only one for the human ear). Research paths and implication of findings in avian directional hearing are discussed.


Subject(s)
Animal Structures , Ear Canal , Gryllidae , Hearing/physiology , Tympanic Membrane , Animal Structures/anatomy & histology , Animal Structures/physiology , Animals , Ear Canal/anatomy & histology , Ear Canal/physiology , Gryllidae/anatomy & histology , Gryllidae/physiology , Tympanic Membrane/anatomy & histology , Tympanic Membrane/physiology
20.
Br J Nurs ; 30(5): 288-295, 2021 Mar 11.
Article in English | MEDLINE | ID: mdl-33733857

ABSTRACT

This article explores body temperature and the physiological process of thermoregulation. Normal body temperature and body temperature changes are discussed, including comorbidities associated with body temperature and signs of hyperthermia and hypothermia, and the factors that affect intraoperative temperature regulation. The evidence base behind thermometry is discussed and is applied to contemporary clinical conditions and symptoms, including: sepsis and suspected COVID-19. After discussing clinical considerations and regulations that encompass thermometry, three case studies present the use of the Genius 3 Tympanic Thermometer in clinical practice, with user feedback supporting its benefits, which include speed, accuracy and ease of use.


Subject(s)
Body Temperature/physiology , Thermometers , Tympanic Membrane/physiology , COVID-19/diagnosis , Complementary Therapies , Critical Care , Humans , Monitoring, Physiologic/instrumentation , Reproducibility of Results , Sepsis/diagnosis , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...