1.
Curr Opin Anaesthesiol ; 37(3): 259-265, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38573182

ABSTRACT

PURPOSE OF REVIEW: To discuss considerations surrounding the use of point-of-care ultrasound (POCUS) in pediatric anesthesiology. RECENT FINDINGS: POCUS is an indispensable tool in various medical specialties, including pediatric anesthesiology. Credentialing for POCUS should be considered to ensure that practitioners are able to acquire images, interpret them correctly, and use ultrasound to guide procedures safely and effectively. In the absence of formal guidelines for anesthesiology, current practice and oversight varies by institution. In this review, we will explore the significance of POCUS in pediatric anesthesiology, discuss credentialing, and compare the specific requirements and challenges currently associated with using POCUS in pediatric anesthesia. SUMMARY: Point-of-care ultrasound is being utilized by the pediatric anesthesiologist and has the potential to improve patient assessment, procedure guidance, and decision-making. Guidelines increase standardization and quality assurance procedures help maintain high-quality data. Credentialing standards for POCUS in pediatric anesthesiology are essential to ensure that practitioners have the necessary skills and knowledge to use this technology effectively and safely. Currently, there are no national pediatric POCUS guidelines to base credentialing processes on for pediatric anesthesia practices. Further work directed at establishing pediatric-specific curriculum goals and competency standards are needed to train current and future pediatric anesthesia providers and increase overall acceptance of POCUS use.


Subject(s)
Anesthesiology , Clinical Competence , Credentialing , Pediatrics , Point-of-Care Systems , Ultrasonography , Humans , Anesthesiology/education , Anesthesiology/standards , Credentialing/standards , Point-of-Care Systems/standards , Child , Pediatrics/education , Pediatrics/standards , Pediatrics/methods , Ultrasonography/standards , Ultrasonography/methods , Clinical Competence/standards , Ultrasonography, Interventional/standards , Ultrasonography, Interventional/methods
2.
J Neurooncol ; 167(3): 387-396, 2024 May.
Article in English | MEDLINE | ID: mdl-38413458

ABSTRACT

PURPOSE: In an era characterized by rapid progression in neurosurgical technologies, traditional tools such as the non-navigated two-dimensional intraoperative ultrasound (nn-2D-IOUS) risk being overshadowed. Against this backdrop, this study endeavors to provide a comprehensive assessment of the clinical efficacy and surgical relevance of nn-2D-IOUS, specifically in the context of glioma resections. METHODS: This retrospective study undertaken at a single center evaluated 99 consecutive, non-selected patients diagnosed with both high-grade and low-grade gliomas. The primary objective was to assess the proficiency of nn-2D-IOUS in generating satisfactory image quality, identifying residual tumor tissue, and its influence on the extent of resection. To validate these results, early postoperative MRI data served as the reference standard. RESULTS: The nn-2D-IOUS exhibited a high level of effectiveness, successfully generating good quality images in 79% of the patients evaluated. With a sensitivity rate of 68% and a perfect specificity of 100%, nn-2D-IOUS unequivocally demonstrated its utility in intraoperative residual tumor detection. Notably, when total tumor removal was the surgical objective, a resection exceeding 95% of the initial tumor volume was achieved in 86% of patients. Additionally, patients in whom residual tumor was not detected by nn-2D-IOUS, the mean volume of undetected tumor tissue was remarkably minimal, averaging at 0.29 cm3. CONCLUSION: Our study supports nn-2D-IOUS's invaluable role in glioma surgery. The results highlight the utility of traditional technologies for enhanced surgical outcomes, even when compared to advanced alternatives. This is particularly relevant for resource-constrained settings and emphasizes optimizing existing tools for efficient patient care. NCT05873946 - 24/05/2023 - Retrospectively registered.


Subject(s)
Brain Neoplasms , Glioma , Standard of Care , Humans , Glioma/surgery , Glioma/diagnostic imaging , Glioma/pathology , Retrospective Studies , Brain Neoplasms/surgery , Brain Neoplasms/diagnostic imaging , Brain Neoplasms/pathology , Male , Female , Middle Aged , Adult , Aged , Neurosurgical Procedures/methods , Neurosurgical Procedures/standards , Monitoring, Intraoperative/methods , Monitoring, Intraoperative/standards , Ultrasonography/methods , Ultrasonography/standards , Young Adult , Neoplasm, Residual/diagnostic imaging , Neoplasm, Residual/surgery , Magnetic Resonance Imaging/methods , Magnetic Resonance Imaging/standards
3.
Zhonghua Yi Xue Za Zhi ; 103(31): 2365-2388, 2023 Aug 22.
Article in Chinese | MEDLINE | ID: mdl-37599213

ABSTRACT

Liver transplantation is currently the only effective treatment for end-stage liver disease. Ultrasound examination has the advantages of non-invasive, convenient, and real-time display the intrahepatic vascular hemodynamic changes, and has become one of the preferred evaluation methods in the entire management process of liver transplantation. To further standardize the ultrasound examinations before and after liver transplantation, multiple-disciplinary experts in the field of liver transplantation, including specialists in ultrasound, liver surgery, and intervention medicine, were organized by the Chinese Medical Association Ultrasound Medicine Branch, the Chinese Medical Doctor Association Surgery Physician Branch, the Chinese Medical Doctor Association Interventional Physician Branch, and the Shanghai Medical Association Ultrasound Medicine Branch. Combined with the latest research practice in ultrasound diagnosis and treatment of liver transplantation, the ultrasound clinical practice guidelines for liver transplantation (2023 edition) was formulated. The contents of this guideline include ultrasound evaluation of liver transplantation donors and recipients, intraoperative and postoperative ultrasound examination of transplant livers, ultrasound applications in pediatric liver transplantation, and ultrasound-guided liver puncture biopsy and treatment, aiming to promote the standardized and high-quality development of liver transplantation ultrasound examination in China.


Subject(s)
Liver Transplantation , Liver , Ultrasonography , Humans , Asian People , China , Liver/diagnostic imaging , Liver/pathology , Liver/surgery , Ultrasonography/methods , Ultrasonography/standards , End Stage Liver Disease/diagnostic imaging , End Stage Liver Disease/surgery
4.
PeerJ ; 11: e15418, 2023.
Article in English | MEDLINE | ID: mdl-37304881

ABSTRACT

Background: The use of sonography is a cost-effective and reliable method to evaluate upper extremity superficial tissue structural integrity and pathology. Establishing the measurement reliability of widely used diagnostic ultrasound evaluation for musculoskeletal assessment is paramount enhance accurate clinical evaluations. The objective of this study was to establish the inter-rater and intra-rater reliability of select ulnar collateral ligament (UCL) thickness measures at two distinct anatomical locations in intercollegiate baseball athletes using ultrasound imaging (USI). Methods: This was a prospective cohort study conducted in a university research laboratory and included a total of 17 NCAA Division I baseball athletes (age 20.4 ± 1.43, height = 183.63 cm ± 6.27 cm, mass = 89.28 kg ± 8.24 kg). Two trained clinicians measured UCL mid-substance and apex thickness in the throwing extremity, prospectively, on 5 occasions at 1-month intervals during rest. Intraclass correlation coefficients (ICCs) (model 3,3), associated standard error of measurement, and 95% minimal detectable change in thickness were derived. Results: Intrarater reliability estimates for operator 1 were 0.90-0.98 (mid-substance) and 0.91-0.99 (apex). Operator 2's values were 0.92-0.97 and 0.93-0.99, respectively. The standard error of measurement (SEM) ranged from 0.045-0.071 cm (mid-substance) and 0.023-0.067 cm (apex). The minimal detectable difference (MDD95) was 0.12-0.20 cm (mid-substance) and 0.07-0.19 cm (apex). Interrater reliability was 0.86-0.96 (mid-substance) and 0.79-0.98 (apex); most ICCs were >0.90. Measurement of UCL thickness at two locations demonstrated very good to excellent reliability with high precision. Using this protocol, two evaluators can obtain consistent UCL measurement at two positions. This finding has significant implications for the clinical evaluation of superficial tissue pathology of the same individual by two experienced practitioners.


Subject(s)
Collateral Ligament, Ulnar , Ultrasonography , Humans , Adolescent , Young Adult , Adult , Collateral Ligament, Ulnar/diagnostic imaging , Ultrasonography/standards , Reproducibility of Results , Prospective Studies , Cohort Studies
5.
Eur Radiol ; 33(9): 6482-6491, 2023 Sep.
Article in English | MEDLINE | ID: mdl-37074423

ABSTRACT

OBJECTIVES: To develop a predictive model using conventional ultrasound combined with CEUS to identify thoracic wall recurrence after mastectomy. METHODS: A total of 162 women with pathologically confirmed thoracic wall lesions (benign 79, malignant 83; median size 1.9 cm, ranging 0.3-8.0 cm) underwent a mastectomy and were checked by both conventional ultrasound and CEUS and were retrospectively included. Logistic regression models of B-mode ultrasound (US) and color Doppler flow imaging (CDFI) with or without CEUS were established to assess the thoracic wall recurrence after mastectomy. The established models were validated by bootstrap resampling. The models were evaluated using calibration curve. The clinical benefit of models were assessed using decision curve analysis. RESULTS: The area under the receiver characteristic was 0.823 (95% CI: 0.76, 0.88) for model using US alone, 0.898 (95% CI: 0.84, 0.94) for model using US combined with CDFI, and 0.959 (95% CI: 0.92, 0.98) for model using US combined with both CDFI and CEUS. The diagnostic performance of the US combined with CDFI was significantly higher than that of the US alone (0.823 vs 0.898, p = 0.002) but significantly lower than that of the US combined with both CDFI and CEUS (0.959 vs 0.898, p < 0.001). Moreover, the unnecessary biopsy rate of the US combined with both CDFI and CEUS was significantly lower than that of the US combined with CDFI (p = 0.037). CONCLUSIONS: Compared to B-mode ultrasound and CDFI, CEUS improves the diagnostic performance to evaluate thoracic wall recurrence after mastectomy. KEY POINTS: • CUES is an effective supplementary method for US in the diagnosis of thoracic wall recurrence after mastectomy. • CEUS combined with both US and CDFI can significantly improve the accuracy of diagnosis of thoracic wall recurrence after mastectomy. • CEUS combined with both US and CDFI can reduce the rate of unnecessary biopsy of thoracic wall lesions after mastectomy.


Subject(s)
Breast Neoplasms , Contrast Media , Neoplasm Recurrence, Local , Thoracic Wall , Ultrasonography , Female , Humans , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/surgery , Diagnosis, Differential , Mastectomy , Retrospective Studies , Sensitivity and Specificity , Thoracic Wall/diagnostic imaging , Ultrasonography/methods , Ultrasonography/standards , Neoplasm Recurrence, Local/diagnostic imaging , Adult , Middle Aged , Aged , Logistic Models
6.
J Clin Ultrasound ; 51(5): 876-878, 2023 Jun.
Article in English | MEDLINE | ID: mdl-37025024

ABSTRACT

High-pressure injection injuries of the hand are uncommon accidents with potentially catastrophic complications. We present a case of a 49-years-old male with a high-pressure injection of motor oil in his left hand. Ultrasound accurately demonstrated soft tissue infiltration and late complications, playing a fundamental role in the treatment choice.


Subject(s)
Hand Injuries , Industrial Oils , Ultrasonography , Humans , Male , Middle Aged , Hand Injuries/diagnostic imaging , Hand Injuries/therapy , Pressure , Injections , Ultrasonography/standards , Magnetic Resonance Imaging , X-Rays
7.
Med Ultrason ; 25(2): 139-144, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-36996386

ABSTRACT

AIM: To evaluate the effect of ultrasound (US) on learning curve and inter-subject performance variability of residents in radial artery cannulation. MATERIAL AND METHODS: Twenty non-anesthesiology residents who received standardized training in an anesthesiology department were selected and divided into two groups: anatomy group or US group. After training of relevant anatomy, US recognition and puncture skill, residents selected 10 patients either under US or anatomical localization performing radial artery catheterization. The number and time of successful cases of catheterization were recorded, success rate of first attempt and catheterization, as well as the total success rate of catheterization were calculated. The learning curve and inter-subject performance variability of residents were also calculated. Complications and the residents' satisfaction for teaching and self-confidence before puncture were also recorded. RESULTS: Compared to the anatomy group, total success rate and the success rate at first attempt were higher in US-guided group (88% vs. 57%, 94% vs. 81%). The average performance time in the US group was significantly less (2.9±0.8 min vs. 4.2±2.1 min) and the mean number of attempts was 1.6, while 2.6 for the anatomy group. With performing cases increasing, the average puncture time of residents in the US group decreased by 19s, while 14s in the anatomy group. More local hematoma occurred in the anatomy group. The satisfaction and confidence degree of residents were higher in US group ([98.5±6.5] vs [68.5±7.3], [90.2±8.6] vs [56.3±5.5]). CONCLUSION: US can significantly shorten the learning curve, reduce the inter-subject performance variability, improve the first attempt and total success rate of radial artery catheterization for non-anesthesiology residents.


Subject(s)
Catheterization, Peripheral , Internship and Residency , Learning Curve , Ultrasonography , Humans , Catheterization, Peripheral/methods , Catheterization, Peripheral/standards , Radial Artery/diagnostic imaging , Ultrasonography/standards , Internship and Residency/methods , Internship and Residency/standards , Work Performance
8.
Med. intensiva (Madr., Ed. impr.) ; 47(1): 16-22, ene. 2023. ilus, tab, graf
Article in English | IBECS | ID: ibc-214317

ABSTRACT

Objective To reduce radiation exposure in newborns admitted due respiratory distress based on the implementation of lung ultrasound (LUS). Design Quality improvement (QI), prospective, before-after, pilot study. Setting Third level neonatal intensive care unit (NICU) level with 25-bed and 1800 deliveries/year. Patients Inclusion criteria were neonates admitted with respiratory distress. Interventions After a theoretical and practical LUS training a new protocol was approved and introduced to the unit were LUS was the first-line image. To study the effect of the intervention we compare two 6-month periods: group 1, with the previous chest X-ray (CXR)-protocol (CXR as the first diagnostic technique) vs. group 2, once LUS-protocol had been implemented. Main variables of interest The main QI measures were the total exposure to radiation. Secondary QI were to evaluate if the LUS protocol modified the clinical evolution as well as the frequency of complications. Results 122 patients were included. The number of CXR was inferior in group 2 (group 1: 2 CXR (IQR 1–3) vs. Group 2: 0 (IQR 0–1), p<0.001), as well as had lower median radiation per baby which received at least one CXR: 56 iGy (IQR 32–90) vs. 30 iGy (IQR 30–32), p<0.001. Respiratory support was similar in both groups, with lower duration of non-invasive mechanical ventilation and oxygen duration the second group (p<0.05). No differences regarding respiratory development complications, length of stay and mortality were found. Conclusions The introduction of LUS protocol in unit decreases the exposure radiation in infants without side effects (AU)


Objetivo Reducir la exposición a la radiación en neonatos ingresados por distrés respiratorio mediante implementación de la ecografía pulmonar (EP). Diseño Estudio piloto, prospectivo, anterior-posterior, mejoría de la calidad. Ámbito Unidad de cuidados intensivos neonatal (UCIN) de tercer nivel con 25 camas y 1800 partos/anuales. Pacientes Criterio de inclusión neonatos con distrés respiratorio. Intervenciones Después de una formación teórico-práctica en EP un nuevo protocolo fue implementado y aprobado siendo la EP la primera técnica de imagen. Para estudiar el efecto de la intervención comparamos dos períodos de 6 meses: grupo 1, con el protocolo de radiografía de tórax (RTX) (RTX primera técnica diagnóstica) vs. grupo 2, una vez implementado el protocolo de EP. Variables de interés La principal variable de interés fue la exposición total a la radiación. Las secundarias fueron la evolución clínica y la frecuencia de complicaciones. Resultados Se incluyeron 122 pacientes. El número de RTX fue inferior en el grupo 2 (grupo 1: 2 RTX [RIQ 1-3] vs. grupo 2: 0 [RIQ 0-1], p<0,001), con una menor dosis de radiación media por cada paciente que recibió al menos una RTX: 56 iGy (RIQ 32-90) vs. 30 iGy (RIQ 30-32), p<0,001. El soporte respiratorio fue similar en ambos grupos, con menor duración de la ventilación no invasiva y oxigenoterapia en el segundo grupo (p< 0,05). No hubo diferencias en el desarrollo de complicaciones respiratorias, días de ingreso o mortalidad. Conclusiones La introducción de un protocolo de EP en una unidad disminuye la exposición a la radiación sin efectos secundarios (AU)


Subject(s)
Humans , Male , Female , Infant, Newborn , Respiratory Insufficiency/diagnostic imaging , Ultrasonography/methods , Lung/diagnostic imaging , Prospective Studies , Pilot Projects , Quality of Health Care , Clinical Protocols , Ultrasonography/standards , Radiation-Protective Agents
10.
Med Oral Patol Oral Cir Bucal ; 28(1): e56-e64, 2023 Jan 01.
Article in English | MEDLINE | ID: mdl-36243993

ABSTRACT

BACKGROUND: Point-of-care-ultrasound can be applied to preview a difficult airway, detect the presence of fluid collection, and soft-tissue edema, and guide the drainage location, although is rarely used. The purpose of this study is to validate a protocol for the assessment of these clinical features on patients with severe odontogenic infections. MATERIAL AND METHODS: This was a single-group prospective cohort study (n=20) including patients with the diagnosis of deep-neck propagation of odontogenic infection. A transcervical linear high-frequency probe transducer (13-6 MHz) was used to scan the structures of the upper airway and the infectious collections. The drainage was guided by ultrasound and the patients were daily evaluated, according to the protocol. The data were extracted and the airway volume, midline deviation, and other important data such as length of hospital stay, dysphagia, voice alteration, raised floor of the mouth, dyspnea, and neck swelling were registered. RESULTS: The ultrasound examination was correlated with multiple clinical findings, such as dyslalia (p=0,069), dysphagia (p=0,028), dyspnea (p=0,001), among others. This protocol has an advantage as it can be used at bedside evaluation, allowing the assessment of severe and unstable patients, and predicting the increase of the hospitalization time (p=0,019). CONCLUSIONS: This protocol is reliable for the assessment of the upper airway, even in an emergency, predicting not only the severity of the clinical features but aids in the determination of the length of the hospitalization time.


Subject(s)
Dentistry , Infections , Point-of-Care Testing , Ultrasonography , Humans , Deglutition Disorders , Dyspnea , Hospitalization , Neck/diagnostic imaging , Prospective Studies , Infection Control, Dental , Point-of-Care Testing/standards , Ultrasonography/standards , Mouth/diagnostic imaging , Dentistry/methods , Infections/diagnostic imaging
11.
J Ultrasound Med ; 42(1): 201-210, 2023 Jan.
Article in English | MEDLINE | ID: mdl-35603734

ABSTRACT

OBJECTIVES: Delayed graft function (DGF) is a common early complication after kidney transplantation. The aim of the present study was to evaluate the value of contrast-enhanced ultrasonography (CEUS) in the early prediction of DGF after kidney transplantation. METHODS: A total of 89 renal transplant recipients were retrospectively enrolled and divided into DGF group or normal graft function (NGF) group according to the allograft function. Conventional Doppler ultrasound and CEUS examination data on the first postoperative day were collected and analyzed. RESULTS: The resistive indices of segmental and interlobar artery in the DGF group were significantly higher than those in the NGF group (0.71 ± 0.17 versus 0.63 ± 0.08, P = .006; 0.70 ± 0.16 versus 0.62 ± 0.08, P = .004, respectively). The patients experiencing DGF had significantly lower PI-c (14.7 dB ± 6.1 dB versus 18.5 dB ± 3.3 dB, P = .001) and smaller AUC-c (779.8 ± 375.8 dB·seconds versus 991.0 ± 211.7 dB·seconds, P = .003), as well as significantly lower PI-m (12.6 dB ± 5.9 dB versus 15.9 dB ± 3.9 dB, P = .006), shorter MTT-m (30.7 ± 9.4 seconds versus 36.3 ± 7.1 seconds, P = .01), and smaller AUC-m (P = .007). Multivariate analysis demonstrated that PI-c, AUC-c, and MTT-m were independent risk factors for DGF. The area under the receiver operating characteristic curve values of the combined predicted value (PI-c + MTT-m, PI-c + AUC-c + MTT-m) of DGF incidence were bigger than that of PI-c, AUC-c, or MTT-m. CONCLUSIONS: CEUS parameters of the cortex and medulla have a good value for an early prediction of DGF after renal transplantation.


Subject(s)
Kidney Transplantation , Ultrasonography , Humans , Delayed Graft Function/epidemiology , Delayed Graft Function/etiology , Graft Survival , Kidney Transplantation/adverse effects , Nerve Growth Factor , Retrospective Studies , Risk Factors , Ultrasonography/standards
12.
Ultraschall Med ; 44(3): 280-289, 2023 Jun.
Article in English | MEDLINE | ID: mdl-33757136

ABSTRACT

OBJECTIVE: To compare the diagnostic accuracy of transvaginal ultrasound (TVS) and magnetic resonance imaging (MRI) for detecting cervical infiltration by endometrial carcinoma using meta-analysis assessment. METHODS: An extensive search of papers comparing TVS and MRI for assessing cervical infiltration in endometrial cancer in the same set of patients was performed in Medline (Pubmed), Web of Science, and the Cochrane Database. Quality was assessed using QUADAS-2 tool (Quality Assessment of Diagnostic Accuracy Studies-2). Quantitative meta-analysis was performed. RESULTS: Our extended search identified 12 articles that used both techniques in the same set of patients and were included in the meta-analysis. The risk of bias for most studies was high for patient selection and index tests in QUADAS-2. Overall, the pooled estimated sensitivity and specificity for diagnosing cervical infiltration in women with endometrial cancer were identical for both techniques [69 % (95 % CI, 51 %-82 %) and 93 % (95 % CI, 90 %-95 %) for TVS, and 69 % (95 % CI, 57 %-79 %) and 91 % (95 % CI, 90 %-95 %) for MRI, respectively]. No statistical differences were found when comparing both methods. Heterogeneity was high for sensitivity and moderate for specificity when analyzing TVS and moderate for both sensitivity and specificity in the case of MRI. CONCLUSION: TVS and MRI showed very similar diagnostic performance for diagnosing cervical involvement in women with endometrial cancer.


Subject(s)
Cervix Uteri , Endometrial Neoplasms , Magnetic Resonance Imaging , Ultrasonography , Female , Humans , Cervix Uteri/diagnostic imaging , Cervix Uteri/pathology , Endometrial Neoplasms/diagnostic imaging , Endometrial Neoplasms/pathology , Magnetic Resonance Imaging/standards , Sensitivity and Specificity , Ultrasonography/standards , Preoperative Period
13.
Med Ultrason ; 25(2): 175-188, 2023 Jun 26.
Article in English | MEDLINE | ID: mdl-36047427

ABSTRACT

Diagnostic ultrasound in obstetrics and gynaecology has experienced a fantastic evolution during the past seven decades. Initial steps with A-mode technology were followed by B-mode and B-mode real-time imaging, then by Doppler and colour Doppler ultrasound, and finally by 3D/4D ultrasound. Other evolutionary steps were the development of high-resolution transabdominal and transvaginal transducers providing high quality images in the first, second and third trimesters of pregancy, as well as in gynaecology and breast imaging.The progression from two-dimensional (2D) to three-dimensional ultrasound (3D) and 3D real-time imaging (4D) has brought new options in displaying anatomical structures. In comparison with CT or MRI, it is not a static but functional technique, cheap and safe, and applicable at any time.


Subject(s)
Gynecology , Obstetrics , Ultrasonography , Ultrasonography/history , Ultrasonography/standards , Obstetrics/history , Obstetrics/instrumentation , Gynecology/history , Gynecology/instrumentation , Humans , Female , Pregnancy , Imaging, Three-Dimensional , Equipment Safety , History, 20th Century , History, 21st Century
14.
Curr Med Sci ; 42(1): 169-176, 2022 Feb.
Article in English | MEDLINE | ID: mdl-35122612

ABSTRACT

OBJECTIVE: To investigate the value of routine intraoperative ultrasound (IU) and intraoperative contrast-enhanced ultrasound (ICEUS) in the surgical treatment of brain tumors, and to explore the utilization of ICEUS for the removal of the remnants surrounding the resection cavity. METHODS: In total, 51 patients who underwent operations from 2012 to 2018 due to different tumors in the brain were included in this study. The clinical data were evaluated retrospectively. IU was performed in all patients, among which 28 patients underwent ICEUS. The effects of IU and ICEUS on tumor resection and recurrence were evaluated. Semiquantitative analysis was performed to compare ICEUS parameters of the brain tumor with those of the surrounding tissue. RESULTS: In total, 36 male and 15 female patients were included in this study. The average age was 43 years (range: 14-68 years). The follow-up period was from 7 to 74 months (mean follow-up 32 months). IU was used in all patients, and no lesion was missed. Among them, 28 patients underwent ICEUS. The rate of total removal of the ICEUS group (23/28, 82%) was significantly higher than that of the IU group (11/23, 48%) (P<0.05). The recurrence rate of ICEUS and IU was 18% (5/23), and 22% (5/28), respectively, and the difference did not reach statistical significance (P>0.05). The semiquantitative analysis showed that the intensity and the transit time of microbubbles reaching the lesions were significantly different from the intensity and the transit time of microbubbles reaching the surrounding tissue (P<0.05) and reflected indirectly the volume and the speed of blood perfusion in the lesions was higher than those in the surrounding tissue. CONCLUSION: ICEUS is a useful tool in localizing and outlining brain lesions, especially for the resection of the hypervascular lesions in the brain. ICEUS could be more beneficial for identifying the remnants and improving the rate of total removal of these lesions than routine intraoperative ultrasound.


Subject(s)
Brain Neoplasms/diagnostic imaging , Brain Neoplasms/surgery , Contrast Media/pharmacokinetics , Intraoperative Neurophysiological Monitoring , Neurosurgical Procedures , Outcome and Process Assessment, Health Care , Ultrasonography , Adolescent , Adult , Aged , Female , Follow-Up Studies , Humans , Intraoperative Neurophysiological Monitoring/methods , Intraoperative Neurophysiological Monitoring/standards , Male , Middle Aged , Neurosurgical Procedures/methods , Neurosurgical Procedures/standards , Retrospective Studies , Ultrasonography/methods , Ultrasonography/standards , Young Adult
15.
J Feline Med Surg ; 24(12): 1228-1237, 2022 12.
Article in English | MEDLINE | ID: mdl-35166136

ABSTRACT

OBJECTIVES: The aim of this study was to determine whether ultrasonographic pancreatic echogenicity, especially hypoechogenicity, has an impact on the prognosis of cats with suspected pancreatitis. We hypothesised that cats with a hypoechoic pancreas have a longer duration of hospitalisation, higher treatment costs and a higher mortality rate. METHODS: This was a retrospective study, which included cats with clinical signs of pancreatitis, a SNAP fPL test result above the reference interval and ultrasonographic abnormalities consistent with pancreatitis. Medical records and follow-up information were retrieved from the local electronic database. Cases were assigned to one of three groups based on pancreatic echogenicity: hypoechoic, hyperechoic or mixed echogenicity. Statistical analysis aimed to assess differences in outcome, ultrasonographic abnormalities, historical features, physical examination findings, laboratory results, concurrent diseases or treatment costs. RESULTS: Thirty-six (64%) cats with a hypoechoic, seven (13%) with a hyperechoic and 13 (23%) cats with a mixed echoic pancreas were included. Cats with a hypoechoic pancreas had a significantly lower median body weight (P = 0.010) and lower median body condition score (P = 0.004) compared with the other cats. Furthermore, they were presented as being lethargic significantly more often (P = 0.014), were more likely to have a homogeneously enlarged pancreas (P <0.001) and were less likely to have concurrent abnormalities or diseases, such as ultrasonographic enteric abnormalities (P = 0.020), triaditis (P = 0.013) and diabetes mellitus (P = 0.041). However, there was no difference in treatment costs (P = 0.961), duration of hospitalisation (P = 0.898), survival of hospitalisation (P = 0.419) or survival time (P = 0.256) between groups. CONCLUSIONS AND RELEVANCE: In this study, echogenicity was of no prognostic value in cats with suspected pancreatitis. Cats with a hypoechoic pancreas were not associated with a poorer outcome than cats with a hyperechoic or mixed echoic pancreas.


Subject(s)
Cat Diseases , Pancreatitis , Ultrasonography , Animals , Cats , Retrospective Studies , Ultrasonography/standards , Pancreatitis/diagnostic imaging , Pancreatitis/veterinary , Predictive Value of Tests , Pancreas/diagnostic imaging , Cat Diseases/diagnostic imaging
17.
Clin Neurophysiol ; 135: 107-116, 2022 03.
Article in English | MEDLINE | ID: mdl-35074720

ABSTRACT

Expert consensus was sought to guide clinicians on the use of electrodiagnostic tests (EDX) and neuromuscular ultrasound (NMUS) in the investigation of suspected carpal tunnel syndrome (CTS). Consensus was achieved using the Delphi method via three consecutive anonymised surveys of 15 experts and was defined as rating agreement ≥ 80%. The panel agreed that combining EDX and NMUS is more informative than using each modality alone. NMUS adds value in patients with clinically suspected CTS with non-localizing or normal EDX, atypical EDX, failed CTS surgery, polyneuropathy, and CTS suspected to be secondary to structural pathology. The median nerve cross-sectional area should be measured at the site of maximal nerve enlargement, and the nerve should be scanned from mid-forearm to the palm. The group also identified those situations where the wrist-to-forearm area ratio and longitudinal scans of the median nerve should also be obtained. EDX should always be performed to quantify CTS severity and in individuals over age 70. This document is an initial step to guide clinicians on the combined investigation of CTS using EDX and NMUS, to be updated regularly with the emergence of new research.


Subject(s)
Carpal Tunnel Syndrome/diagnosis , Electrodiagnosis/methods , Ultrasonography/methods , Carpal Tunnel Syndrome/diagnostic imaging , Carpal Tunnel Syndrome/physiopathology , Consensus , Electrodiagnosis/standards , Humans , Neuromuscular Junction/diagnostic imaging , Neuromuscular Junction/physiology , Practice Guidelines as Topic , Ultrasonography/standards
18.
Am J Physiol Heart Circ Physiol ; 322(3): H359-H372, 2022 03 01.
Article in English | MEDLINE | ID: mdl-34995167

ABSTRACT

Ischemic heart disease is the leading cause of death in the United States, Canada, and worldwide. Severe disease is characterized by coronary artery occlusion, loss of blood flow to the myocardium, and necrosis of tissue, with subsequent remodeling of the heart wall, including fibrotic scarring. The current study aims to demonstrate the efficacy of quantitating infarct size via two-dimensional (2-D) echocardiographic akinetic length and four-dimensional (4-D) echocardiographic infarct volume and surface area as in vivo analysis techniques. We further describe and evaluate a new surface area strain analysis technique for estimating myocardial infarction (MI) size after ischemic injury. Experimental MI was induced in mice via left coronary artery ligation. Ejection fraction and infarct size were measured through 2-D and 4-D echocardiography. Infarct size established via histology was compared with ultrasound-based metrics via linear regression analysis. Two-dimensional echocardiographic akinetic length (r = 0.76, P = 0.03), 4-D echocardiographic infarct volume (r = 0.85, P = 0.008), and surface area (r = 0.90, P = 0.002) correlate well with histology. Although both 2-D and 4-D echocardiography were reliable measurement techniques to assess infarct, 4-D analysis is superior in assessing asymmetry of the left ventricle and the infarct. Strain analysis performed on 4-D data also provides additional infarct sizing techniques, which correlate with histology (surface strain: r = 0.94, P < 0.001, transmural thickness: r = 0.76, P = 0.001). Two-dimensional echocardiographic akinetic length, 4-D echocardiography ultrasound, and strain provide effective in vivo methods for measuring fibrotic scarring after MI.NEW & NOTEWORTHY Our study supports that both 2-D and 4-D echocardiographic analysis techniques are reliable in quantifying infarct size though 4-D ultrasound provides a more holistic image of LV function and structure, especially after myocardial infarction. Furthermore, 4-D strain analysis correctly identifies infarct size and regional LV dysfunction after MI. Therefore, these techniques can improve functional insight into the impact of pharmacological interventions on the pathophysiology of cardiac disease.


Subject(s)
Myocardial Infarction/diagnostic imaging , Ultrasonography/methods , Algorithms , Animals , Cardiac Output , Female , Heart Ventricles/diagnostic imaging , Heart Ventricles/pathology , Heart Ventricles/physiopathology , Imaging, Three-Dimensional/methods , Imaging, Three-Dimensional/standards , Male , Mice , Myocardial Infarction/pathology , Myocardial Infarction/physiopathology , Sensitivity and Specificity , Ultrasonography/standards
19.
Brain Res Bull ; 179: 68-73, 2022 02.
Article in English | MEDLINE | ID: mdl-34871709

ABSTRACT

OBJECTIVE: The purpose of the present study was to assess whether optic nerve sheath diameter (ONSD) measured by ultrasound could predict brain injury in sepsis associated encephalopathy (SAE). METHODS: A total of 48 male New Zealand White rabbits were used to establish sepsis model. The levels of neuro-specific enolase (NSE), S100B, myeloperoxidase (MPO), and tumor necrosis factor-α (TNF-α) were detected by enzyme-linked immuno sorbent assay and ONSD were measured before modeling, 6 h, 12 h and 24 h after modeling. Sixteen rabbits were sacrificed for hematoxylin-eosin (HE) staining of brain tissue and the brain water content at above time points. Rabbits demonstrated brain injury by HE staining were included in the SAE group, the others were enrolled in the control group. The correlation between ONSD and MPO, NSE and S100B in the SAE group were analyzed. Receiver operator characteristic curves were generated to analyze the area under the curve (AUC), specificity and sensitivity of ONSD values for SAE. RESULTS: Twenty-nine of 48 rabbits had brain injury, while 19 cases were enrolled in the control group. The level of MPO, NSE, S100B, TNF-α at 6 h, 12 h and 24 h in SAE group were all higher than those of the control group with statistical significance. The ONSD in SAE group increased with time and significantly wider than those in the control group. Correlation analysis revealed that ONSD was positively correlated with MPO, NSE and S100B in the SAE group. The AUCs for the ONSD value in diagnosing SAE at 6 h, 12 h and 24 h were 0.864, 0.957, 0.877, respectively. CONCLUSIONS: Alterations in ONSD strongly correlated with MPO, NSE and S100B among SAE rabbits. Monitoring of ONSD exhibited a high predictive value for SAE.


Subject(s)
Optic Nerve/diagnostic imaging , Peroxidase/metabolism , Phosphopyruvate Hydratase/metabolism , S100 Calcium Binding Protein beta Subunit/metabolism , Sepsis-Associated Encephalopathy/diagnostic imaging , Sepsis-Associated Encephalopathy/metabolism , Animals , Biomarkers/metabolism , Disease Models, Animal , Humans , Male , Predictive Value of Tests , Rabbits , Ultrasonography/standards
20.
Can J Cardiol ; 38(3): 338-346, 2022 03.
Article in English | MEDLINE | ID: mdl-34871728

ABSTRACT

BACKGROUND: Strict isolation precautions limit formal echocardiography use in the setting of COVID-19 infection. Information on the importance of handheld focused ultrasound for cardiac evaluation in these patients is scarce. This study investigated the utility of a handheld echocardiography device in hospitalised patients with COVID-19 in diagnosing cardiac pathologies and predicting the composite end point of in-hospital death, mechanical ventilation, shock, and acute decompensated heart failure. METHODS: From April 28 through July 27, 2020, consecutive patients diagnosed with COVID-19 underwent evaluation with the use of handheld ultrasound (Vscan Extend with Dual Probe; GE Healthcare) within 48 hours of admission. The patients were divided into 2 groups: "normal" and "abnormal" echocardiogram, as defined by biventricular systolic dysfunction/enlargement or moderate/severe valvular regurgitation/stenosis. RESULTS: Among 102 patients, 26 (25.5%) had abnormal echocardiograms. They were older with more comorbidities and more severe presenting symptoms compared with the group with normal echocardiograms. The prevalences of the composite outcome among low- and high-risk patients (oxygen saturation < 94%) were 3.1% and 27.1%, respectively. Multivariate logistic regression analysis revealed that an abnormal echocardiogram at presentation was independently associated with the composite end point (odds ratio 6.19, 95% confidence interval 1.50-25.57; P = 0.012). CONCLUSIONS: An abnormal echocardiogram in COVID-19 infection settings is associated with a higher burden of medical comorbidities and independently predicts major adverse end points. Handheld focused echocardiography can be used as an important "rule-out" tool among high-risk patients with COVID-19 and should be integrated into their routine admission evaluation. However, its routine use among low-risk patients is not recommended.


Subject(s)
COVID-19/complications , Echocardiography/instrumentation , Heart Diseases/diagnostic imaging , Lung Diseases/diagnostic imaging , Ultrasonography/instrumentation , Aged , Echocardiography/standards , Female , Heart Diseases/etiology , Hospitalization , Humans , Lung Diseases/etiology , Male , Middle Aged , Prospective Studies , SARS-CoV-2 , Ultrasonography/standards