Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 299
Filter
1.
Radiat Prot Dosimetry ; 200(13): 1274-1293, 2024 Aug 09.
Article in English | MEDLINE | ID: mdl-39003236

ABSTRACT

The verification and use of the best treatment approach using 3D conformal radiation therapy (3DCRT), intensity modulated radiation therapy (IMRT) and Rapid Arc methods for left breast radiation with dosimetric and radiobiological characteristics. The use of custom-built Python software for the estimation and comparison of volume, mean dose, maximum dose, monitor units and normal tissue integral dose along with radiobiological parameters such as NTCP, tumor control probability, equivalent uniform dose and LKB's effective volume from 3DCRT, IMRT and Rapid Arc planning with deep inspiration with breath holding (DIBH) and free breadth (FB) techniques. Volume growth of three-fourth in DIBH compared with FB causes a decrease in cardiac doses and complications because the left lung expands, pulling the heart away from the chest wall and the treatment area. A tiny area of the left lung was exposed during treatment, which reduced the mean dose. There was little difference in the treatment approaches because the spinal cord was immobile in both techniques. Rapid Arc is the unmatched modality for left-sided breast irradiation with significant patient breath-hold, as shown by the comparison of dosimetric and radiobiological parameters from treatment techniques with a deep inspiration breath-hold approach.


Subject(s)
Breath Holding , Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy, Conformal/methods , Organs at Risk/radiation effects , Radiometry/methods
2.
Curr Oncol ; 31(6): 3189-3198, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38920725

ABSTRACT

Women with left-sided breast cancer receiving adjuvant radiotherapy have increased incidence of cardiac mortality due to ischemic heart disease; to date, no threshold dose for late cardiac/pulmonary morbidity or mortality has been established. We investigated the likelihood of cardiac death and radiation pneumonitis in women with left-sided breast cancer who received comprehensive lymph node irradiation. The differences in dosimetric parameters between free-breathing (FB) and deep inspiration breath hold (DIBH) techniques were also addressed. Based on NTCP calculations, the probability of cardiac death was significantly reduced with the DIBH compared to the FB technique (p < 0.001). The risk of radiation pneumonitis was not clinically significant. There was no difference in coverage between FB and DIBH plans. Doses to healthy structures were significantly lower in DIBH plan than in FB plan for V20, V30, and ipsilateral total lung volume. Inspiratory gating reduces the dose absorbed by the heart without compromising the target range, thus reducing the likelihood of cardiac death.


Subject(s)
Unilateral Breast Neoplasms , Humans , Female , Unilateral Breast Neoplasms/radiotherapy , Middle Aged , Aged , Lymphatic Irradiation/methods , Radiotherapy Dosage , Radiotherapy, Adjuvant/methods , Adult , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Lymph Nodes/pathology , Lymph Nodes/radiation effects
3.
Technol Cancer Res Treat ; 23: 15330338241259633, 2024.
Article in English | MEDLINE | ID: mdl-38887092

ABSTRACT

PURPOSE: We report a dosimetric study in whole breast irradiation (WBI) of plan robustness evaluation against position error with two radiation techniques: tangential intensity-modulated radiotherapy (T-IMRT) and multi-angle IMRT (M-IMRT). METHODS: Ten left-sided patients underwent WBI were selected. The dosimetric characteristics, biological evaluation and plan robustness were evaluated. The plan robustness quantification was performed by calculating the dose differences (Δ) of the original plan and perturbed plans, which were recalculated by introducing a 3-, 5-, and 10-mm shift in 18 directions. RESULTS: M-IMRT showed better sparing of high-dose volume of organs at risk (OARs), but performed a larger low-dose irradiation volume of normal tissue. The greater shift worsened plan robustness. For a 10-mm perturbation, greater dose differences were observed in T-IMRT plans in nearly all directions, with higher ΔD98%, ΔD95%, and ΔDmean of CTV Boost and CTV. A 10-mm shift in inferior (I) direction induced CTV Boost in T-IMRT plans a 1.1 (ΔD98%), 1.1 (ΔD95%), and 1.7 (ΔDmean) times dose differences greater than dose differences in M-IMRT plans. For CTV Boost, shifts in the right (R) and I directions generated greater dose differences in T-IMRT plans, while shifts in left (L) and superior (S) directions generated larger dose differences in M-IMRT plans. For CTV, T-IMRT plans showed higher sensitivity to a shift in the R direction. M-IMRT plans showed higher sensitivity to shifts in L, S, and I directions. For OARs, negligible dose differences were found in V20 of the lungs and heart. Greater ΔDmax of the left anterior descending artery (LAD) was seen in M-IMRT plans. CONCLUSION: We proposed a plan robustness evaluation method to determine the beam angle against position uncertainty accompanied by optimal dose distribution and OAR sparing.


Subject(s)
Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Female , Organs at Risk/radiation effects , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Radiometry/methods , Middle Aged
4.
Cancer Radiother ; 28(3): 265-271, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38897883

ABSTRACT

PURPOSE: Breast-conserving surgery followed by reirradiation for a localized ipsilateral breast tumour relapse may increase the radiation dose delivered to the heart and result in a greater risk of cardiac adverse events. This study aimed to compare the incidence of cardiac mortality in patients treated for a localized ipsilateral breast tumour relapse, either with breast-conserving surgery followed by reirradiation or with total mastectomy between 2000 and 2020. MATERIALS AND METHODS: All patients treated for a primary non-metastatic breast cancer with breast-conserving surgery and adjuvant radiotherapy were identified in the Surveillance, Epidemiology, and End Results (SEER) program database, and those who subsequently experienced a localized ipsilateral breast tumour relapse treated with breast-conserving surgery and reirradiation ("BCS+ReRT" group, n=239) or with total mastectomy ("TM" group, n=3127) were included. The primary objective was to compare the cardiac mortality rate between the patients who underwent breast-conserving surgery followed by reirradiation and total mastectomy. Secondary endpoints were overall survival and cancer specific survival. RESULTS: Cardiac mortality was significantly higher in patients treated with breast-conserving surgery followed by reirradiation (hazard ratio [HR]: 2.40, 95% confidence interval [95% CI]: 1.19-4.86, P=0.006) in univariate analysis; non-statistically significant differences were observed after adjusting for age, laterality and chemotherapy on multivariate analysis (HR: 1.96, 95% CI: 0.96-3.94, P=0.067), age being the only confounding factor. A non-statistically significant difference towards lower overall survival was observed in patients who had breast-conserving surgery followed by reirradiation compared with those who underwent total mastectomy (HR: 1.37, 95% CI: 0.98-1.90, P=0.066), and no differences were observed in terms of cancer specific survival (HR: 1.01, 95% CI: 0.56-1.82, P=0.965). CONCLUSION: In this study, the incidence of cardiac mortality was low, and breast-conserving surgery followed by reirradiation did not independently increased the risk of cardiac mortality for a localized ipsilateral breast tumour relapse.


Subject(s)
Mastectomy, Segmental , Neoplasm Recurrence, Local , Re-Irradiation , Humans , Female , Middle Aged , Neoplasm Recurrence, Local/radiotherapy , Neoplasm Recurrence, Local/mortality , Re-Irradiation/methods , Aged , Radiotherapy, Adjuvant , Adult , SEER Program , Breast Neoplasms/radiotherapy , Breast Neoplasms/mortality , Breast Neoplasms/surgery , Breast Neoplasms/pathology , Mastectomy , Unilateral Breast Neoplasms/radiotherapy , Unilateral Breast Neoplasms/surgery , Retrospective Studies , Incidence
5.
J Appl Clin Med Phys ; 25(8): e14365, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38760907

ABSTRACT

PURPOSE: With proper beam setup and optimization constraints in the treatment planning system, volumetric modulated arc therapy (VMAT) can improve target dose coverage and conformity while reducing doses to adjacent structures for whole breast radiation therapy. However, the low-dose bath effect on critical structures, especially the heart and the ipsilateral lung, remains a concern. In this study, we present a VMAT technique with the jaw offset VMAT (JO-VMAT) to reduce the leakage and scatter doses to critical structures for whole breast radiation therapy. MATERIALS AND METHODS: The data of 10 left breast cancer patients were retrospectively used for this study. CT images were acquired on a CT scanner (GE, Discovery) with the deep-inspiration breath hold (DIBH) technique. The planning target volumes (PTVs) and the normal structures (the lungs, the heart, and the contralateral breast) were contoured on the DIBH scan. A 3D field-in-field plan (3D-FiF), a tangential VMAT (tVMAT) plan, and a JO-VMAT plan were created with the Eclipse treatment planning system. An arc treatment field with the x-jaw closed across the central axis creates a donut-shaped high-dose distribution and a cylinder-shaped low-dose volume along the central axis of gantry rotation. Applying this setup with proper multi-leaf collimator (MLC) modulation, the optimized plan potentially can provide sufficient target coverage and reduce unnecessary irradiation to critical structures. The JO-VMAT plans involve 5-6 tangential arcs (3 clockwise arcs and 2-3 counterclockwise arcs) with jaw offsets. The plans were optimized with objective functions specified to achieve PTV dose coverage and homogeneity; For organs at risk (OARs), objective functions were specified individually for each patient to accomplish the best achievable treatment plan. For tVMAT plans, optimization constraints were kept the same except that the jaw offset was removed from the initial beam setup. The dose volume histogram (DVH) parameters were generated for dosimetric evaluation of PTV and OARs. RESULTS: The D95% to the PTV was greater than the prescription dose of 42.56 Gy for all the plans. With both VMAT techniques, the PTV conformity index (CI) was statistically improved from 0.62 (3D-FiF) to 0.83 for tVMAT and 0.84 for JO-VMAT plans. The difference in the homogeneity index (HI) was not significant. The Dmax to the heart was reduced from 12.15 Gy for 3D-FiF to 8.26 Gy for tVMAT and 7.20 Gy for JO-VMAT plans. However, a low-dose bath effect was observed with tVMAT plans to all the critical structures including the lungs, the heart, and the contralateral breast. With JO-VMAT, the V5Gy and V2Gy of the heart were reduced by 32.7% and 15.4% compared to 3D-FiF plans. Significantly, the ipsilateral lung showed a reduction in mean dose (4.65-3.44 Gy) and low dose parameters (23.4% reduction for V5Gy and 10.7% reduction for V2Gy) for JO-VMAT plans compared to the 3D-FiF plans. The V2Gy dose to the contralateral lung and breast was minimal with JO-VMAT techniques. CONCLUSION: A JO-VMAT technique was evaluated in this study and compared with 3D-FiF and tVMAT techniques. Our results showed that the JO-VMAT technique can achieve clinically comparable coverage and homogeneity and significantly improve dose conformity within PTV. Additionally, JO-VMAT eliminated the low-dose bath effect at all OARs evaluation metrics including the ipsilateral/contralateral lung, the heart, and the contralateral breast compared to 3D-FiF and tVMAT. This technique is feasible for the whole breast radiation therapy of left breast cancers.


Subject(s)
Organs at Risk , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy, Intensity-Modulated , Humans , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Female , Retrospective Studies , Breast Neoplasms/radiotherapy , Unilateral Breast Neoplasms/radiotherapy , Tomography, X-Ray Computed/methods , Heart/radiation effects
6.
J Egypt Natl Canc Inst ; 36(1): 11, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38584227

ABSTRACT

BACKGROUND: The moderate deep inspiratory breath hold (mDIBH) is a modality famed for cardiac sparing. Prospective studies based on this are few from the eastern part of the world and India. We intend to compare the dosimetry between mDIBH and free-breathing (FB) plans. METHODS: Thirty-two locally advanced left breast cancer patients were taken up for the study. All patients received a dose of 50 Gy in 25 fractions to the chest wall/intact breast, followed by a 10-Gy boost to the lumpectomy cavity in the case of breast conservation surgery. All the patients were treated in mDIBH using active breath coordinator (ABC). The data from the two dose volume histograms were compared regarding plan quality and the doses received by the organs at risk. Paired t-test was used for data analysis. RESULTS: The dose received by the heart in terms of V5, V10, and V30 (4.55% vs 8.39%) and mean dose (4.73 Gy vs 6.74 Gy) were statistically significant in the ABC group than that in the FB group (all p-values < 0.001). Also, the dose received by the LADA in terms of V30 (19.32% vs 24.87%) and mean dose (32.99 Gy vs 46.65 Gy) were significantly less in the ABC group. The mean treatment time for the ABC group was 20 min, while that for the free-breathing group was 10 min. CONCLUSIONS: Incorporating ABC-mDIBH for left-sided breast cancer radiotherapy significantly reduces the doses received by the heart, LADA, and left and right lung, with no compromise in plan quality but with an increase in treatment time.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Prospective Studies , Heart , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Organs at Risk
7.
Radiother Oncol ; 195: 110229, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38492672

ABSTRACT

BACKGROUND AND PURPOSE: To evaluate the performance of automated surface-guided gating for left-sided breast cancer with DIBH and VMAT. MATERIALS AND METHODS: Patients treated in the first year after introduction of DIBH with VMAT were retrospectively considered for analysis. With automated surface-guided gating the beam automatically switches on/off, if the surface region of interest moved in/out the gating tolerance (±3 mm, ±3°). Patients were coached to hold their breath as long as comfortably possible. Depending on the patient's preference, patients received audio instructions during treatment delivery. Real-time positional variations of the breast/chest wall surface with respect to the reference surface were collected, for all three orthogonal directions. The durations and number of DIBHs needed to complete dose delivery, and DIBH position variations were determined. To evaluate an optimal gating window threshold, smaller tolerances of ±2.5 mm, ±2.0 mm, and ±1.5 mm were simulated. RESULTS: 525 fractions from 33 patients showed that median DIBH duration was 51 s (range: 30-121 s), and median 4 DIBHs per fraction were needed to complete VMAT dose delivery. Median intra-DIBH stability and intrafractional DIBH reproducibility approximated 1.0 mm in each direction. No large differences were found between patients who preferred to perform the DIBH procedure with (n = 21) and without audio-coaching (n = 12). Simulations demonstrated that gating window tolerances could be reduced from ±3.0 mm to ±2.0 mm, without affecting beam-on status. CONCLUSION: Independent of the use of audio-coaching, this study demonstrates that automated surface-guided gating with DIBH and VMAT proved highly efficient. Patients' DIBH performance far exceeded our expectations compared to earlier experiences and literature. Furthermore, gating window tolerances could be reduced.


Subject(s)
Radiotherapy, Intensity-Modulated , Humans , Female , Retrospective Studies , Middle Aged , Aged , Radiotherapy, Intensity-Modulated/methods , Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Unilateral Breast Neoplasms/radiotherapy , Adult , Radiotherapy Dosage
8.
Radiother Oncol ; 194: 110195, 2024 May.
Article in English | MEDLINE | ID: mdl-38442840

ABSTRACT

BACKGROUND AND PURPOSE: Partial breast irradiation (PBI)has beenthe Danish Breast Cancer Group(DBCG) standard for selected breast cancer patients since 2016 based onearlyresults from the DBCG PBI trial.During trial accrual, respiratory-gated radiotherapy was introduced in Denmark. This study aims to investigate the effect of respiratory-gating on mean heart dose (MHD). PATIENTS AND METHODS: From 2009 to 2016 the DBCG PBI trial included 230 patientswith left-sided breast cancer receiving external beam PBI, 40 Gy/15 fractions/3 weeks.Localization of the tumor bed on the planning CT scan, the use of respiratory-gating, coverage of the clinical target volume (CTV), and doses to organs at risk were collected. RESULTS: Respiratory-gating was used in 123 patients (53 %). In 176 patients (77 %) the tumor bed was in the upper and in 54 patients (23 %) in the lower breast quadrants. The median MHD was 0.37 Gy (interquartile range 0.26-0.57 Gy), 0.33 Gy (0.23-0.49 Gy) for respiratory-gating, and 0.49 Gy (0.31-0.70 Gy) for free breathing, p < 0.0001. MHD was < 1 Gy in 206 patients (90 %) and < 2 Gy in 221 patients (96 %). Respiratory-gating led to significantly lower MHD for upper-located, but not for lower-located tumor beds, however, all MHD were low irrespective of respiratory-gating. Respiratory-gating did not improve CTV coverage or lower lung doses. CONCLUSIONS: PBI ensured a low MHD for most patients. Adding respiratory-gating further reduced MHD for upper-located but not for lower-located tumor beds but did not influence target coverage or lung doses. Respiratory-gating is no longer DBCG standard for left-sided PBI.


Subject(s)
Organs at Risk , Humans , Female , Middle Aged , Organs at Risk/radiation effects , Denmark , Aged , Breast Neoplasms/radiotherapy , Breast Neoplasms/pathology , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy Dosage , Heart/radiation effects , Radiotherapy Planning, Computer-Assisted/methods , Respiratory-Gated Imaging Techniques/methods , Adult
9.
Acta Oncol ; 63: 56-61, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38404218

ABSTRACT

BACKGROUND AND PURPOSE: Proton therapy for breast cancer is usually given in free breathing (FB). With the use of deep inspiration breath-hold (DIBH) technique, the location of the heart is displaced inferiorly, away from the internal mammary nodes and, thus, the dose to the heart can potentially be reduced. The aim of this study was to explore the potential benefit of proton therapy in DIBH compared to FB for highly selected patients to reduce exposure of the heart and other organs at risk. We aimed at creating proton plans with delivery times feasible with treatment in DIBH. MATERIAL AND METHODS: Sixteen patients with left-sided breast cancer receiving loco-regional proton therapy were included. The FB and DIBH plans were created for each patient using spot-scanning proton therapy with 2-3 fields, robust and single field optimization. For the DIBH plans, minimum monitor unit per spot and spot spacing were increased to reduce treatment delivery time. RESULTS: All plans complied with target coverage constraints. The median mean heart dose was statistically significant reduced from 1.1 to 0.6 Gy relative biological effectiveness (RBE) by applying DIBH. No statistical significant difference was seen for mean dose and V17Gy RBE to the ipsilateral lung. The median treatment delivery time for the DIBH plans was reduced by 27% compared to the FB plans without compromising the plan quality. INTERPRETATION: The median absolute reduction in dose to the heart was limited. Proton treatment in DIBH may only be relevant for a subset of these patients with the largest reduction in heart exposure.


Subject(s)
Breast Neoplasms , Proton Therapy , Radiation Injuries , Unilateral Breast Neoplasms , Humans , Female , Breast Neoplasms/radiotherapy , Protons , Radiotherapy Dosage , Breath Holding , Radiotherapy Planning, Computer-Assisted/methods , Heart , Unilateral Breast Neoplasms/radiotherapy , Organs at Risk
10.
J Appl Clin Med Phys ; 25(6): e14271, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38273673

ABSTRACT

PURPOSE: The use of volumetric modulated arc therapy (VMAT), simultaneous integrated boost (SIB), and hypofractionated regimen requires adequate patient setup accuracy to achieve an optimal outcome. The purpose of this study was to assess the setup accuracy of patients receiving left-sided breast cancer radiotherapy using deep inspiration breath-hold technique (DIBH) and surface guided radiotherapy (SGRT) and to calculate the corresponding setup margins. METHODS: The patient setup accuracy between and within radiotherapy fractions was measured by comparing the 6DOF shifts made by the SGRT system AlignRT with the shifts made by kV-CBCT. Three hundred and three radiotherapy fractions of 23 left-sided breast cancer patients using DIBH and SGRT were used for the analysis. All patients received pre-treatment DIBH training and visual feedback during DIBH. An analysis of variance (ANOVA) was used to test patient setup differences for statistical significance. The corresponding setup margins were calculated using the van Herk's formula. RESULTS: The intrafractional patient setup accuracy was significantly better than the interfractional setup accuracy (p < 0.001). The setup margin for the combined inter- and intrafractional setup error was 4, 6, and 4 mm in the lateral, longitudinal, and vertical directions if based on SGRT alone. The intrafractional error contributed ≤1 mm to the calculated setup margins. CONCLUSION: With SGRT, excellent intrafractional and acceptable interfractional patient setup accuracy can be achieved for the radiotherapy of left-sided breast cancer using DIBH and modern radiation techniques. This allows for reducing the frequency of kV-CBCTs, thereby saving treatment time and radiation exposure.


Subject(s)
Breath Holding , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted , Radiotherapy Setup Errors , Radiotherapy, Image-Guided , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy, Intensity-Modulated/methods , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy Setup Errors/prevention & control , Radiotherapy, Image-Guided/methods , Organs at Risk/radiation effects , Middle Aged , Breast Neoplasms/radiotherapy , Prognosis
11.
Sci Rep ; 14(1): 2400, 2024 01 29.
Article in English | MEDLINE | ID: mdl-38287139

ABSTRACT

Radiotherapy with deep inspiration breath hold (DIBH) reduces doses to the lungs and organs at risk. The stability of breath holding and reproducibility of tumor location are higher during expiration than during inspiration; therefore, we developed an irradiation method combining DIBH and real-time tumor-tracking radiotherapy (RTRT) (DBRT). Nine patients were enrolled in this study. Fiducial markers were placed near tumors using bronchoscopy. Treatment planning computed tomography (CT) was performed thrice during DIBH, assisted by spirometer-based device. Each CT scan was fused using fiducial markers. Gross tumor volume (GTV) was contoured for each dataset and summed to create GTVsum; adding a 5-mm margin around GTVsum generated the planning target volume. The prescribed dose was mainly 42 Gy in four fractions. The treatment plan was created using DIBH CT (DBRT-plan), with a similar treatment plan created for expiratory CT for cases for which DBRT could not be performed (conv-plan). Vx defined as the volume of the lung received x Gy, and the mean lung dose, V20, V10, and V5 were evaluated. DBRT was completed in all patients. Mean dose, V20, and V10 were significantly lower in the DBRT-plan than in the conv-plan (all p = 0.003). Mean rates of decrease for mean dose, V20, and V10 were 14.0%, 27.6%, and 19.1%, respectively. No significant difference was observed in V5. We developed DBRT, a stereotactic body radiation therapy performed with the DIBH technique; it combines a spirometer-based breath-hold support system with an RTRT system. All patients who underwent DBRT completed the procedure without any technical or mechanical complications. This is a promising methodology that may significantly reduce lung doses.


Subject(s)
Lung Neoplasms , Unilateral Breast Neoplasms , Humans , Breath Holding , Reproducibility of Results , Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Lung/diagnostic imaging , Lung/radiation effects , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk/radiation effects , Heart/radiation effects , Unilateral Breast Neoplasms/radiotherapy
12.
Phys Med ; 117: 103203, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38171219

ABSTRACT

Setup errors are an important factor in the dosimetric accuracy of radiotherapy delivery. In this study, we investigated how rotational setup errors influence the dose distribution in volumetric modulated arc therapy (VMAT) and tangential field-in-field (FiF) treatment of left-sided breast cancer with supraclavicular lymph node involvement in deep inspiration breath hold. Treatment planning computed tomography images and radiotherapy plans of 20 patients were collected retrospectively for the study. Rotational setup errors up to 3° were simulated by rotating the planning images, and the resulting dosimetric changes were calculated. With rotational setup errors up to 3°, the median decrease of V95% to clinical target volume was less than 0.8 percentage point in both VMAT and FiF plans. The dose distribution of the heart and left anterior descending artery was more stable with respect to rotations in VMAT plans compared to FiF plans. Correction of ≥1° setup errors is recommended due to increased doses to the heart and left anterior descending artery after 1° setup errors.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy, Intensity-Modulated/methods , Unilateral Breast Neoplasms/diagnostic imaging , Unilateral Breast Neoplasms/radiotherapy , Retrospective Studies , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Organs at Risk
13.
Strahlenther Onkol ; 200(1): 71-82, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37380796

ABSTRACT

PURPOSE: The robustness of surface-guided (SG) deep-inspiration breath-hold (DIBH) radiotherapy (RT) for left breast cancer was evaluated by investigating any potential dosimetric effects due to the residual intrafractional motion allowed by the selected beam gating thresholds. The potential reduction of DIBH benefits in terms of organs at risk (OARs) sparing and target coverage was evaluated for conformational (3DCRT) and intensity-modulated radiation therapy (IMRT) techniques. METHODS: A total of 192 fractions of SGRT DIBH left breast 3DCRT treatment for 12 patients were analyzed. For each fraction, the average of the real-time displacement between the isocenter on the daily reference surface and on the live surface ("SGRT shift") during beam-on was evaluated and applied to the original plan isocenter. The dose distribution for the treatment beams with the new isocenter point was then calculated and the total plan dose distribution was obtained by summing the estimated perturbed dose for each fraction. Then, for each patient, the original plan and the perturbed one were compared by means of Wilcoxon test for target coverage and OAR dose-volume histogram (DVH) metrics. A global plan quality score was calculated to assess the overall plan robustness against intrafractional motion of both 3DCRT and IMRT techniques. RESULTS: Target coverage and OAR DVH metrics did not show significant variations between the original and the perturbed plan for the IMRT techniques. 3DCRT plans showed significant variations for the left descending coronary artery (LAD) and the humerus only. However, none of the dose metrics exceeded the mandatory dose constraints for any of the analyzed plans. The global plan quality analysis indicated that both 3DCRT and IMRT techniques were affected by the isocenter shifts in the same way and, generally, the residual isocenter shifts more likely tend to worsen the plan in all cases. CONCLUSION: The DIBH technique proved to be robust against residual intrafractional isocenter shifts allowed by the selected SGRT beam-hold thresholds. Small-volume OARs located near high dose gradients showed significant marginal deteriorations in the perturbed plans with the 3DCRT technique only. Global plan quality was mainly influenced by patient anatomy and treatment beam geometry rather than the technique adopted.


Subject(s)
Breast Neoplasms , Radiotherapy, Conformal , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Breath Holding , Radiotherapy, Conformal/methods , Breast Neoplasms/radiotherapy , Radiotherapy, Intensity-Modulated/methods , Organs at Risk , Unilateral Breast Neoplasms/radiotherapy
14.
Int J Radiat Oncol Biol Phys ; 118(3): 632-638, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-37797748

ABSTRACT

PURPOSE: Limiting cardiac radiation dose is important for minimizing long-term cardiac toxicity in patients with left-sided early-stage breast cancer. METHODS AND MATERIALS: Prospectively collected dosimetric data were analyzed for patients undergoing moderately hypofractionated radiation therapy to the left breast within the Michigan Radiation Oncology Quality Consortium from 2016 to 2022. The mean heart dose (MHD) goal was progressively tightened from ≤2 Gy in 2016 to MHD ≤ 1.2 Gy in 2018. In 2021, a planning target volume (PTV) coverage goal was added, and the goal MHD was reduced to ≤1 Gy. Multivariate logistic regression models were developed to assess for covariates associated with meeting the MHD goals in 2016 to 2020 and the combined MHD/PTV coverage goal in 2021 to 2022. RESULTS: In total, 4165 patients were analyzed with a median age of 64 years. Overall average cardiac metric compliance was 91.7%. Utilization of motion management increased from 41.8% in 2016 to 2020 to 46.5% in 2021 to 2022. Similarly, use of prone positioning increased from 12.2% to 22.2% in these periods. On multivariate analysis in the 2016 to 2020 cohort, treatment with motion management (odds ratio [OR], 5.20; 95% CI, 3.59-7.54; P < .0001) or prone positioning (OR, 3.21; 95% CI, 1.85-5.57; P < .0001) was associated with meeting the MHD goal, while receipt of boost (OR, 0.25; 95% CI, 0.17-0.39; P < .0001) and omission of hormone therapy (OR, 0.65; 95% CI, 0.49-0.88; P = .0047) were associated with not meeting the MHD goal. From 2021 to 2022, treatment with motion management (OR, 1.89; 95% CI, 1.12-3.21; P = .018) or prone positioning (OR, 3.71; 95% CI, 1.73-7.95; P = .0008) was associated with meeting the combined MHD/PTV goal, while larger breast volume (≥1440 cc; OR, 0.34; 95% CI, 0.13-0.91; P = .031) was associated with not meeting the combined goal. CONCLUSIONS: In our statewide consortium, high rates of compliance with aggressive targets for limiting cardiac dose were achievable without sacrificing target coverage.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Middle Aged , Female , Radiotherapy Dosage , Unilateral Breast Neoplasms/radiotherapy , Drug Tapering , Breast Neoplasms/radiotherapy , Heart , Radiotherapy Planning, Computer-Assisted/methods
15.
J Radiat Res ; 65(1): 87-91, 2024 Jan 19.
Article in English | MEDLINE | ID: mdl-38091980

ABSTRACT

The purpose of this study was to show the safety of volumetric modulated arc therapy (VMAT) with deep inspiration breath-hold (DIBH) in hypofractionated radiotherapy for left-sided breast cancer after breast-conserving surgery in a clinical setting. Twenty-five Japanese women, aged 20-59 years, who were enrolled in this prospective non-inferiority study received VMAT under the condition of DIBH with 42.4 Gy/16 fractions for whole-breast irradiation (WBI) ± boost irradiation for the tumor bed to show the non-inferiority of VMAT with DIBH to conventional fractionated WBI with free breathing. The primary endpoint was the rate of occurrence of radiation dermatitis of Grade 3 or higher or pneumonitis of Grade 2 or higher within 6 months after the start of radiotherapy. This study was registered with UMIN00004321. All of the enrolled patients completed the planned radiotherapy without interruption. The evaluation of adverse events showed that three patients (12.0%) had Grade 2 radiation dermatitis. There was no other Grade 2 adverse event and there was no patient with an adverse event of Grade 3 or higher. Those results confirmed our hypothesis that the experimental treatment method is non-inferior compared with our historical results. There was no patient with locoregional recurrence or metastases. In conclusion, VMAT under the condition of DIBH in hypofractionated radiotherapy for left-sided breast cancer after breast-conserving surgery can be performed safely in a clinical setting.


Subject(s)
Breast Neoplasms , Dermatitis , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Female , Humans , Radiotherapy, Intensity-Modulated/methods , Mastectomy, Segmental , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Unilateral Breast Neoplasms/radiotherapy , Prospective Studies , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Neoplasm Recurrence, Local , Dermatitis/etiology , Heart , Organs at Risk
16.
Radiol Oncol ; 57(4): 530-537, 2023 12 01.
Article in English | MEDLINE | ID: mdl-38038420

ABSTRACT

BACKGROUND: Cardioprotection is valued in radiotherapy for patients with left-sided breast cancer. Deep inspiration breath-hold (DIBH) technique can achieve cardioprotection well. However, during DIBH, the extent to which the heart enters the radiation field is affected by the movement of the thorax and diaphragm. The aim of this study was to analyze the correlation between the maximum distance of the heart entering the field (maximum heart distance, MHD) and thoracic diameter changes and diaphragmatic descent in left-sided breast cancer patients during DIBH. PATIENTS AND METHODS: Ninety-eight patients with left-sided breast cancer were included in this retrospective study. They performed simulation in Sentinel-guided DIBH, and two sets of CT images were collected under both free breathing (FB) and DIBH, and diaphragm positions, anteroposterior thoracic diameter (ATD), transverse thoracic diameter (TTD), gating window level (GWL), and MHD were measured, and the change (Δ) of each parameter in DIBH relative to that in FB were calculated. Pearson or Spearman test were used to analyze the correlation between ΔMHD and the changes in other parameters. RESULTS: For all patients with DIBH, the average of ΔMHD was -8.3 mm, and the average of ΔATD and ΔTTD were 11.0 and 8.6 mm, and the median of both left diaphragmatic descent (LDD) and right diaphragmatic descent (RDD) were 35.0 mm, and the median of GWL was 11.1 mm. The correlation coefficients between MHD decrease (ΔMHD) and LDD, RDD, and ΔTTD were -0.430 (p = 0.000), -0.592 (p = 0.000) and 0.208 (p = 0.040), respectively, but not significantly correlated with ΔATD or GWL. CONCLUSIONS: The MHD decrease showed a moderate correlation with diaphragmatic descent In Sentinel-guided DIBH for patients with left-sided breast cancer, while there was a weak or no correlation with thoracic diameter changes or GWL. Abdominal breathing can lower diaphragm more and may be more beneficial to the heart stay away from tangential field.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Diaphragm/diagnostic imaging , Breath Holding , Radiotherapy Dosage , Unilateral Breast Neoplasms/diagnostic imaging , Unilateral Breast Neoplasms/radiotherapy , Retrospective Studies , Breast Neoplasms/diagnostic imaging , Breast Neoplasms/radiotherapy , Thorax
17.
Curr Oncol ; 30(12): 10530-10538, 2023 12 18.
Article in English | MEDLINE | ID: mdl-38132402

ABSTRACT

In breast cancer volumetric-modulated arc therapy (VMAT) planning, the rotation of the gantry around the target implies a greater dose spreading to the whole heart, compared to tangential-field standard treatment. A consecutive cohort of 121 breast cancer patients treated with the VMAT technique was investigated. The correlation of breast volume, heart volume and lung volume with mean heart dose (mHD) and mean and maximum LAD dose (mLAD dose, MLAD dose) was tested, and a subsequent a linear regression analysis was carried out. VMAT treatment plans from 56 left breast cancer and 65 right breast cancer patients were analyzed. For right-sided patients, breast volume was significantly correlated with mHD, mLAD and MLAD dose, while for left-sided patients, breast volume was significantly correlated with mHD and mLAD, while heart volume and lung volume were correlated with mHD, mLAD and MLAD dose. Breast volume was the only predictor of increased heart and LAD dose (p ≤ 0.001) for right-sided patients. In left-sided patients, heart and lung were also predictors of increased mHD (p = 0.005, p ≤ 0.001) and mean LAD dose (p = 0.009, p ≤ 0.001). In this study, we observed an increase in heart and LAD doses in larger-breasted patients treated with VMAT planning. In right-sided patients, breast volume was shown to be the only predictor of increased heart dose and LAD dose.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Unilateral Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Breast Neoplasms/radiotherapy
18.
Radiat Oncol ; 18(1): 200, 2023 Dec 14.
Article in English | MEDLINE | ID: mdl-38098106

ABSTRACT

BACKGROUND: Breast cancer is the most widespread cancer in women and young women worldwide. Moving towards customised radiotherapy, balancing the use of the available technology with the best treatment modality may not be an easy task in the daily routine. This study aims to evaluate the effectiveness of introducing IQ-feasibility into clinical practice to support the decision of free-breathing (FB) versus breath-hold (BH) left-sided breast irradiations, in order to optimise the technology available and the effectiveness of the treatment. METHODS: Thirty-five patients who received 3D radiotherapy treatment of the left breast in deep-inspiration BH were included in this retrospective study. Computed tomography scans in FB and BH were acquired for each patient; targets contoured in both imaging datasets by an experienced radiation oncologist, and organs at risk delineated using automatic segmentation software were exported to PlanIQ™ (Sun Nuclear Corp.) to generate feasibility dose volume histogram (FDVHs). The dosimetric parameter of BH versus FB FDVH, and BH clinical dataset versus BH FDVH were compared. RESULTS: A total of 30 patients out of 35 patients analysed, presented for the BH treatments a significant reduction (p < 0.05) in the heart mean dose ([Formula: see text]), volume receiving 5 Gy ([Formula: see text]) and 20 Gy ([Formula: see text]), of 35.7%, 54.5%, and 2.1%, respectively; for the left lung, a lower reduction was registered and significant only for [Formula: see text] (21.4%, p = 0.046). For the remaining five patients, the FDVH cut-off points of heart and lung were superimposable with differences of less than 1%. Heart and left lung dosimetric parameters of the BH clinical plans are located in the difficult zone of the FDVH and differ significantly (p < 0.05) from the corresponding parameters of the FDVH curves delimiting this buffer area between the impossible and feasible zones, respectively. CONCLUSION: The use of PlanIQTM as a decision-support tool for the FB versus BH treatment delivery modality allows customisation of the treatment technique using the most appropriate technology for each patient enabling accurate management of available technologies.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Female , Humans , Breath Holding , Retrospective Studies , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Respiration , Breast Neoplasms/radiotherapy , Heart/radiation effects , Unilateral Breast Neoplasms/radiotherapy , Organs at Risk/radiation effects
19.
Acta Oncol ; 62(12): 1873-1879, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37909907

ABSTRACT

BACKGROUND/PURPOSE: Gastric dose parameters comparison for deep inspiration breath-hold (DIBH) or free breathing (FB) mode during radiotherapy (RT) for left-sided breast cancer patients (LSBCPs) has not been investigated before. This study aimed to analyze the impact of Active Breath Coordinator (ABC)-DIBH technique on the dose received by the stomach during RT for LSBCPs and to provide organ-specific dosimetric parameters. MATERIALS AND METHODS: The study included 73 LSBCPs. The dosimetric parameters of the stomach were compared between FB and DIBH mode. The correlation between the stomach volume and dosimetric parameters was analyzed. RESULTS: Compared to FB mode, statistically significant reductions were observed in gastric dose parameters in ABC-DIBH mode, including Dmax (46.60 vs 17.25, p < 0.001), D1cc (38.42 vs 9.60, p < 0.001), Dmean (4.10 vs 0.80, p < 0.001), V40Gy (0.50 vs 0.00, p < 0.001), V30Gy (6.30 vs 0.00, p < 0.001), V20Gy (20.80 vs 0.00, p < 0.001), V10Gy (51.10 vs 0.77, p < 0.001), and V5Gy (93.20 vs 9.60, p < 0.001). ABC-DIBH increased the distance between the stomach and the breast PTV when compared to FB, from 1.3 cm to 2.8 cm (p < 0.001). Physiologic decrease in stomach volume was not found from FB to ABC-DIBH (415.54 cm3 vs 411.61 cm3, p = 0.260). The stomach volume showed a positive correlation with V40Gy (r2 = 0.289; p < 0.05), V30Gy (r2 = 0.287; p < 0.05), V20Gy (r2 = 0.343; p < 0.05), V10Gy (r2 = 0.039; p < 0.001), V5Gy (r2 = 0.439; p < 0.001), Dmax (r2 = 0.269; p < 0.05) and D1cc (r2 = 0.278; p < 0.05) in FB mode. While in ABC-DIBH mode, most stomach dosimetric parameters were not correlated with gastric volume. CONCLUSIONS: The implementation of ABC-DIBH in LSBCPs radiotherapy resulted in lower irradiation of the stomach. Larger stomach volume was associated with statistically significantly higher dose irradiation in FB mode. To reduce radiotherapy related side effects in FB mode, patients should be fast for at least 2 hours before the CT simulation and treatment.


Subject(s)
Breast Neoplasms , Unilateral Breast Neoplasms , Humans , Female , Breast Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Radiotherapy Dosage , Breath Holding , Unilateral Breast Neoplasms/radiotherapy , Stomach , Radiation Dosage , Heart/radiation effects , Organs at Risk/radiation effects
20.
Medicine (Baltimore) ; 102(46): e36064, 2023 Nov 17.
Article in English | MEDLINE | ID: mdl-37986375

ABSTRACT

To research the influence of the minimum segment width (MSW) on intensity-modulated radiotherapy (IMRT) plan for left breast cancer after breast conserving surgery and provide a reference for plan optimization. Ten patients with left-sided early-stage breast cancer after breast-conserving surgery (BCS) were selected for postoperative radiotherapy. The Monaco 5.11 treatment planning system (TPS) was used, and the optimization parameters of the plan were fixed, while MSW were set to 0.5, 1, 1.5, and 2 cm, and four 5 field-IMRT plans were designed for every patient. The plan quality and execution efficiency of each plan were compared, including planning target volume (PTV) dose, organs at risk (OAR) dose, segments number (SN), monitor units (MU), delivery time (DT), and dose verification results. With the increase of the MSW, the dose indexes of the OAR were similar (P > .05). The D2%, D98%, and D50% of the PTV gradually deviated from the prescription dose, and the uniformity gradually deteriorated (P < .05). The gamma passing rates (GPR) of dose verification and the dose deviation of the PTV were similar (P > .05). The SN, MU, and DT gradually decreased (P < .05), but the amplitude change caused by each increase of 0.5 cm gradually decreased, the decrease of 0.5 to 1 cm was the largest, reaching 16.41%, 21.25%, and 0.35 minutes, respectively, while the 3 values of 1.5 and 2 cm were close. When using Monaco 5.11 TPS to design IMRT plan for left breast cancer after BCS, 1.5 cm MSW could ensure better dose coverage and uniformity of the PTV, as little as possible exposure dose to the OAR, and high dose verification accuracy. The SN, MU, and DT were significantly reduced, and the treatment efficiency was improved.


Subject(s)
Breast Neoplasms , Radiotherapy, Intensity-Modulated , Unilateral Breast Neoplasms , Humans , Female , Unilateral Breast Neoplasms/radiotherapy , Breast Neoplasms/radiotherapy , Breast Neoplasms/surgery , Mastectomy, Segmental , Radiotherapy, Intensity-Modulated/methods , Radiotherapy Dosage , Radiotherapy Planning, Computer-Assisted/methods , Organs at Risk
SELECTION OF CITATIONS
SEARCH DETAIL