Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 591
Filter
1.
Circ Cardiovasc Interv ; 17(6): e013842, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38708595

ABSTRACT

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.


Subject(s)
Endovascular Procedures , Hemostatic Techniques , Suture Techniques , Vascular Closure Devices , Humans , Prospective Studies , Male , Female , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Treatment Outcome , Time Factors , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Aged, 80 and over , Equipment Design , Punctures , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Hemorrhage/prevention & control , Hemorrhage/etiology , Middle Aged , Transcatheter Aortic Valve Replacement/adverse effects , Transcatheter Aortic Valve Replacement/instrumentation , Risk Factors , Aortic Aneurysm, Abdominal/surgery , Aortic Aneurysm, Abdominal/diagnostic imaging , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/instrumentation , Aortic Aneurysm, Thoracic/surgery , Aortic Aneurysm, Thoracic/diagnostic imaging
2.
World Neurosurg ; 188: e305-e311, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38796148

ABSTRACT

OBJECTIVE: Puncture-site complications in interventional radiology sometimes cause severe conditions. Vascular closure devices play an important role in preventing puncture-site complications. Vascular closure devices are divided into 2 types, the directly suturing or clipping type (active approximators) and adherent sealant types (passive approximators). However, which types of vascular closure device are the safest and most effective for achieving hemostasis remains unclear. We analyzed the efficacy of each type of vascular closure device and risk factors for puncture-site complications. METHODS: This study investigated 327 consecutive cases of neuroendovascular surgery using a transfemoral procedure during a 2-year study period. Passive approximators (Angioseal [St Jude Medical, Saint Paul, MN] and Exoseal [Cordis Corporation, Miami, FL]) were mainly used in the first half and active approximators (Perclose [Abbot Vascular, Santa Clara, CA]) in the second. We compared groups and estimated risk factors for puncture-site complications. RESULTS: All procedures were successful. Comparing groups with and without puncture-site complications, use of passive approximators and ≥3 antithrombotic medications tended to be more frequent and distance from skin to femoral artery and body mass index tended to be lower in the group with complications without significance. The cutoff for femoral artery depth calculated from a receiver operating characteristic curve was 16.43 mm. Multivariate analysis revealed ≥3 antithrombotic medications (P = 0.002, OR 15.29, 95% CI 2.76-85.76) and passive approximator use in patients with femoral artery depth <16.43 mm (P < 0.001, OR 17.08, 95% CI 2.95-57.80) were significantly higher in the group with puncture-site complications. CONCLUSIONS: Passive approximator use in patients with shallow femoral artery depth increases puncture-site complications in neuroendovascular treatment.


Subject(s)
Endovascular Procedures , Femoral Artery , Punctures , Vascular Closure Devices , Humans , Femoral Artery/surgery , Male , Female , Middle Aged , Aged , Punctures/adverse effects , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Adult , Risk Factors , Retrospective Studies , Aged, 80 and over
3.
Europace ; 26(5)2024 May 02.
Article in English | MEDLINE | ID: mdl-38647070

ABSTRACT

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Subject(s)
Atrial Fibrillation , Catheter Ablation , Pulmonary Veins , Suture Techniques , Humans , Atrial Fibrillation/surgery , Female , Male , Middle Aged , Catheter Ablation/adverse effects , Catheter Ablation/methods , Prospective Studies , Pulmonary Veins/surgery , Suture Techniques/adverse effects , Aged , Treatment Outcome , Germany , Time Factors , Vascular Closure Devices , Early Ambulation , Hemostatic Techniques/instrumentation
4.
Ann Vasc Surg ; 105: 125-131, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38588952

ABSTRACT

BACKGROUND: Endovascular aortic surgery is increasingly becoming the standard treatment. Percutaneous access preclosing systems appear to be effective and notably the Proglide (PG). We aimed to prospectively assess the clinical effectiveness of combining ultrasound-guided femoral puncture with ultrasound-guided PG deployment. METHODS: Our single-center study consecutively included patients managed at a tertiary center from May to September 2023, undergoing endovascular aortic surgery. The placement of PG was performed under ultrasound guidance. Preoperative patient characteristics were evaluated using preoperative computed tomography scans. Clinical and technical success were defined, respectively, as the ability to achieve complete hemostasis confirmed by ultrasound 48 hr postprocedure and as the successful placement of a PG under ultrasound guidance contributing to final hemostasis. RESULTS: Twenty patients were included over a 6-month period, totaling 34 common femoral arteries (CFAs). Fourteen were male, with an average age of 72.8 ± 8.2 years. Among the 34 CFA, CFA had diameter of 12.05 ± 2.4 mm and a depth of 38.0 ± 13.4 mm. The mean introducer sheath diameter was 6.2 ± 1.5 mm with a sheath to femoral artery ratio of 0.54 ± 0.18. Successful Proglide placement under ultrasound guidance was achieved in 100% of cases. No PG failure occurred. Clinical and technical success were, respectively, of 95% and 100%. One small pseudoaneurysm was observed at 48 hr treated medically. No CFA access reintervention was required. CONCLUSIONS: The technique of ultrasound-guided PG deployment in aortic surgery is a safe and effective method for achieving hemostasis. It effectively prevents PG failures at a lower cost.


Subject(s)
Endovascular Procedures , Femoral Artery , Hemostatic Techniques , Punctures , Ultrasonography, Interventional , Humans , Male , Endovascular Procedures/adverse effects , Endovascular Procedures/instrumentation , Female , Aged , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Treatment Outcome , Prospective Studies , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Aged, 80 and over , Middle Aged , Catheterization, Peripheral/adverse effects , Vascular Closure Devices , Hemostatics/administration & dosage , Hemostatics/therapeutic use , Time Factors
5.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38639140

ABSTRACT

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Subject(s)
Catheterization, Peripheral , Femoral Artery , Hemostatic Techniques , Punctures , Suture Techniques , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Femoral Artery/diagnostic imaging , Male , Female , Transcatheter Aortic Valve Replacement/instrumentation , Transcatheter Aortic Valve Replacement/adverse effects , Prospective Studies , Aged, 80 and over , Treatment Outcome , Catheterization, Peripheral/adverse effects , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Suture Techniques/adverse effects , Suture Techniques/instrumentation , Risk Factors , Time Factors , Aortic Valve/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Italy , Equipment Design , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Hemorrhage/etiology , Hemorrhage/prevention & control
6.
Catheter Cardiovasc Interv ; 103(5): 771-781, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38451155

ABSTRACT

BACKGROUND: ProGlide is a percutaneous suture-mediated closure device used in arterial and venous closure following percutaneous intervention. Risk of vascular complications from use, particularly related to failure in hemostasis, or acute vessel closure, remains significant and often related to improper suture deployment. We describe a technique of ultrasound-guided ProGlide deployment in transfemoral transcatheter aortic valve implantation (TF-TAVI). AIMS: The aim of this study is to assess vascular outcomes for ultrasound-guided deployment of ProGlide vascular closure devices in patients undergoing TF-TAVI. METHODS: We collected relevant clinical data of patients undergoing TAVI in a large volume centre. PRIMARY OUTCOME: main access Valve Academic Research Consortium 3 (VARC-3) major vascular complication. SECONDARY OUTCOME: any major/minor VARC-3 vascular complication, its type (bleed or ischemia), and treatment required (medical, percutaneous, or surgical). We performed inverse weighting propensity score analysis to compare the population undergoing ultrasound-guided versus conventional ProGlide deployment for main TAVI access. Ultrasound technique for ProGlide insertion was performed as described below. RESULTS: Five hundred and seventeen patients undergoing TF-TAVI were included. PRIMARY OUTCOME: In 126 (ultrasound-guided) and 391 (conventional ProGlide insertion), 0% versus 1.8% (p < 0.001) had a major VARC-3 vascular complication, respectively. SECONDARY OUTCOME: 0.8% (one minor VARC-3 bleed) vs 4.1% (13 bleeds and three occlusions) had any VARC-3 vascular complication (major and minor) (p < 0.001). Surgical treatment of vascular complication was required in 0.8% versus 1.3% (p = NS). CONCLUSIONS: Ultrasound-guided deployment of ProGlide for vascular closure reduced the risk of major vascular complications in a large population undergoing TAVI.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve Stenosis/complications , Cohort Studies , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Treatment Outcome , Hemorrhage/etiology , Risk Reduction Behavior , Ultrasonography, Interventional/adverse effects , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
7.
Vasc Endovascular Surg ; 58(6): 588-594, 2024 Aug.
Article in English | MEDLINE | ID: mdl-38477544

ABSTRACT

OBJECTIVES: Manual compression (MC) or vascular closure devices (VCDs) are used to achieve hemostasis after percutaneous transluminal angioplasty (PTA). However, limited data on the comparative safety and effectiveness of VCDs vs MC in patients with end-stage renal disease (ESRD) undergoing PTA are available. Accordingly, this study compared the safety and effectiveness of VCD and MC in patients with ESRD undergoing PTA. METHODS: This single-center retrospective cohort study included the data of patients with ESRD undergoing peripheral intervention at Chang Gung Memorial Hospital, Taiwan, from January 1, 2019, to June 30, 2022. The patients were divided into VCD and MC groups. The primary endpoint was a composite of puncture site complications, including acute limb ischemia, marked hematoma, pseudoaneurysm, and puncture site bleeding requiring blood transfusion. RESULTS: We included 264 patients with ESRD undergoing PTA, of whom 60 received a VCD and 204 received MC. The incidence of puncture site complications was 3.3% in the VCD group and 4.4% in the MC group (hazard ratio: .75; 95% confidence interval: .16-3.56 L P = 1.000), indicating no significant between-group difference. CONCLUSION: VCDs and MC had comparable safety and effectiveness for hemostasis in patients with ESRD undergoing peripheral intervention.


Subject(s)
Hemostatic Techniques , Kidney Failure, Chronic , Peripheral Arterial Disease , Punctures , Vascular Closure Devices , Humans , Male , Female , Retrospective Studies , Aged , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Kidney Failure, Chronic/therapy , Kidney Failure, Chronic/diagnosis , Kidney Failure, Chronic/complications , Middle Aged , Treatment Outcome , Peripheral Arterial Disease/therapy , Peripheral Arterial Disease/diagnostic imaging , Taiwan , Risk Factors , Time Factors , Pressure , Hemorrhage/etiology , Aged, 80 and over , Risk Assessment
8.
Catheter Cardiovasc Interv ; 103(4): 650-659, 2024 03.
Article in English | MEDLINE | ID: mdl-38407552

ABSTRACT

BACKGROUND: Vascular complications increase morbidity and mortality in transcatheter aortic valve replacement (TAVR). Data involving suture-based percutaneous vascular closure devices (VCDs) have been extensive. Although promising, data regarding the efficacy and safety of the MANTA VCD (Teleflex) are scarce. We sought to assess the safety and effectiveness of the MANTA device in a real-life unselected cohort of patients undergoing transfemoral-TAVR (TF-TAVR). METHODS: This single-center retrospective observational study included a cohort of consecutive patients with severe aortic stenosis (AS) treated by our team using TAVR between January 2020 to December 2022. The primary outcome measure was access-related major and minor vascular complications according to the Valve Academic Research Consortium (VARC-3) definition criteria. RESULTS: From January 2020 to December 2022, a total of 347 patients underwent TF-TAVR were treated using the MANTA 18 Fr VCD system for vascular closure. Mean age was 82.4 ± 6.1 years (56-98 years). There were no significant differences in preoperative and procedural characteristics between patients with and without VCD-related major vascular complications. Access site-related major and minor vascular complications occurred in 20 of 347 patients (5.7%). Overall, major vascular complications occurred in 5 patients (1.4%) and device failure was seen in 17 patients (4.9%). CONCLUSION: This French real world evaluation of large-bore arteriotomy closure in TF-TAVR indicated that MANTA VCD is a feasible alternative with an acceptable low rate of access-site-related complications.


Subject(s)
Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Aged , Aged, 80 and over , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Catheterization, Peripheral/adverse effects , Punctures
9.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article in English | MEDLINE | ID: mdl-38184452

ABSTRACT

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Subject(s)
Catheterization, Peripheral , Extracorporeal Membrane Oxygenation , Heart-Assist Devices , Hemostatic Techniques , Punctures , Vascular Closure Devices , Humans , Retrospective Studies , Male , Female , Treatment Outcome , Middle Aged , Aged , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/instrumentation , Time Factors , Hemostatic Techniques/instrumentation , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects , Catheterization, Peripheral/instrumentation , Device Removal/adverse effects , Suture Techniques/instrumentation , Suture Techniques/adverse effects , Femoral Artery , Shock, Cardiogenic/therapy , Shock, Cardiogenic/mortality , Shock, Cardiogenic/physiopathology , Shock, Cardiogenic/diagnosis , Risk Factors , Hemorrhage/etiology , Hemorrhage/prevention & control
10.
J Vasc Surg ; 79(4): 740-747.e2, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38056701

ABSTRACT

BACKGROUND: Percutaneous access and use of vascular closure devices facilitate thoracic endovascular aortic repair (TEVAR) procedures during local anesthesia and allow immediate detection of signs of spinal ischemia. However, the very large bore access (usually ≥22F sheath) associated with TEVAR increases the risk of vascular complications. In this study, we sought to define the safety and feasibility of two percutaneous femoral artery closure devices during TEVAR, in terms of access site vascular complications and major, life-threatening, or fatal bleeding (≥major) within 48 hours. Access site vascular complications were defined as technical failure of vascular closure or later formation of pseudoaneurysm. METHODS: From March 2010 to December 2022, 199 transfemoral TEVAR were performed at Helsinki University Central Hospital, Finland. We retrospectively categorized these into three groups, based on surgeon preference for the access technique and femoral artery closure method: (1) surgical cut-down and vessel closure, n = 85 (42.7%), (2) percutaneous access and vascular closure with suture-based ProGlide, n = 56 (28.1%), or (3) percutaneous access and vascular closure with ultrasound-guided plug-based MANTA, n = 58 (29.1%). The primary outcome measure was technical success of vascular closure and access site vascular complications during index hospitalization. Secondary outcome measures were ≥major bleeding, early mortality, and hospital stay. RESULTS: The technical success rate was 97.6% vs 91.1% vs 93.1% for surgical cut-down, ProGlide, and MANTA, respectively (P = .213). The rate of access site vascular complication was 3.5% vs 8.9% vs 10.3%, respectively (P = .290), with two pseudoaneurysms detected postoperatively and conservatively managed in the MANTA group. The vascular closure method was not associated with increased risk of ≥major bleeding, early mortality, or hospital stay on univariate analysis. Predictors for ≥major bleeding after TEVAR in multivariable analysis were urgent procedure (odds ratio: 2.8, 95% confidence interval: 1.4-5.5; P = .003) and simultaneous aortic branch revascularization (odds ratio: 2.7, 95% confidence interval: 1.3-5.4; P = .008). CONCLUSIONS: In this study, the technical success rates of the percutaneous techniques demonstrated their feasibility during TEVAR. However, the number of access site complications for percutaneous techniques was higher compared with open approach, although the difference was not statistically significant. In the lack of evidence, the safety of the new MANTA plug-based vascular closure for TEVAR warrants further investigation.


Subject(s)
Catheterization, Peripheral , Endovascular Procedures , Vascular Closure Devices , Humans , Endovascular Aneurysm Repair , Retrospective Studies , Treatment Outcome , Hemorrhage/etiology , Hemorrhage/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Catheterization, Peripheral/adverse effects
11.
J Vasc Surg ; 79(3): 569-576, 2024 Mar.
Article in English | MEDLINE | ID: mdl-37923021

ABSTRACT

OBJECTIVE: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR). METHODS: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up. RESULTS: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m2. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events. CONCLUSIONS: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.


Subject(s)
Aortic Aneurysm , Endovascular Procedures , Vascular Closure Devices , Humans , Aged , Aged, 80 and over , Endovascular Procedures/adverse effects , Hemostatic Techniques , Retrospective Studies , Treatment Outcome , Aortic Aneurysm/diagnostic imaging , Aortic Aneurysm/surgery , Femoral Artery/diagnostic imaging , Femoral Artery/surgery
12.
EuroIntervention ; 20(1): 66-74, 2024 Jan 01.
Article in English | MEDLINE | ID: mdl-37800723

ABSTRACT

BACKGROUND: Randomised controlled trials of ultrasound (US)-guided transfemoral access (TFA) for coronary procedures have shown mixed results. AIMS: We aimed to compare US-guided versus non-US-guided TFA from randomised data in an individual participant-level data (IPD) meta-analysis. METHODS: We completed a systematic review and an IPD meta-analysis of all randomised controlled trials comparing US-guided versus non-US-guided TFA for coronary procedures. We performed a one-stage mixed-model meta-analysis using the intention-to-treat population from included trials. The primary outcome was a composite of major vascular complications or major bleeding within 30 days. RESULTS: A total of 2,441 participants (1,208 US-guided, 1,233 non-US-guided) from 4 randomised clinical trials were included. The mean age was 65.5 years, 27.0% were female, and 34.5% underwent a percutaneous coronary intervention. The incidence of major vascular complications or major bleeding (34/1,208 [2.8%] vs 55/1,233 [4.5%]; odds ratio [OR] 0.61, 95% confidence interval [CI]: 0.39-0.94; p=0.026) was lower in the US-guided TFA group. In the prespecified subgroup of participants who received a vascular closure device, those randomised to US-guided TFA experienced a reduction in the primary outcome (2.1% vs 5.6%; OR 0.36, 95% CI: 0.19-0.69), while no benefit for US guidance was observed in the subgroup without vascular closure devices (4.1% vs 3.3%; OR 1.21, 95% CI: 0.65-2.26; interaction p=0.009). CONCLUSIONS: In participants undergoing coronary procedures by TFA, US guidance decreased the composite outcome of major vascular complications or bleeding and may be especially helpful when using vascular closure devices.


Subject(s)
Percutaneous Coronary Intervention , Vascular Closure Devices , Humans , Female , Aged , Male , Hemorrhage/etiology , Percutaneous Coronary Intervention/adverse effects , Ultrasonography/adverse effects , Vascular Closure Devices/adverse effects , Femoral Artery/diagnostic imaging , Treatment Outcome , Radial Artery
13.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Article in English | MEDLINE | ID: mdl-37982158

ABSTRACT

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Subject(s)
Aortic Valve Stenosis , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Femoral Artery/surgery , Hemorrhage/etiology , Hemorrhage/prevention & control , Hemostatic Techniques/adverse effects , Transcatheter Aortic Valve Replacement/methods , Treatment Outcome , Vascular Closure Devices/adverse effects
14.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Article in English | MEDLINE | ID: mdl-38059295

ABSTRACT

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Subject(s)
Aortic Valve Stenosis , Catheterization, Peripheral , Transcatheter Aortic Valve Replacement , Vascular Closure Devices , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Treatment Outcome , Femoral Artery/diagnostic imaging , Femoral Artery/surgery , Catheterization, Peripheral/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Aortic Valve/diagnostic imaging , Aortic Valve/surgery , Hemostatic Techniques/adverse effects
15.
J Vet Cardiol ; 51: 124-137, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38128418

ABSTRACT

INTRODUCTION/OBJECTIVES: Manual compression has been standard of care for maintaining hemostasis after percutaneous endovascular intervention, but can be time-consuming and associated with vascular complications. Alternative closure methods include the figure-of-eight suture (Z-stitch) and vascular closure device (VCD) techniques. We hypothesized that compared to manual compression, Z-stitch and VCD would significantly reduce time-to-hemostasis after transvenous access, and the proportion of dogs with vascular patency would not differ significantly among treatments. ANIMALS: Forty-six client-owned dogs undergoing percutaneous transvenous interventional procedures. MATERIALS AND METHODS: Dogs with vessel diameter <5 mm were randomized to undergo manual compression or Z-stitch, while those with vessel diameter ≥5 mm were randomized to undergo manual compression, Z-stitch, or VCD. Time-to-hemostasis, bleeding scores, presence of vascular patency one day and two to three months post-procedure, and complications were recorded. Data are presented as median (95% confidence interval). RESULTS: In all 46 dogs, the right external jugular vein was used. Time-to-hemostasis was significantly shorter in the Z-stitch (2.1 [1.8-2.9] minutes) compared to VCD (8.6 [6.1-11.8] minutes; P<0.001) and manual compression (10.0 [10.0-20.0] minutes; P<0.001) groups. Time-to-hemostasis was significantly shorter in the VCD vs. manual compression (P=0.027) group. Bleeding scores were significantly greater at 5 and 10 min (P<0.001 and 0.013, respectively) in manual compression, compared to Z-stitch group. There was no difference in the proportion of dogs with vascular patency between groups (P=0.59). CONCLUSIONS: Z-stitch and VCD are effective venous hemostasis methods after percutaneous transvenous intervention, with Z-stitch providing the most rapid time-to-hemostasis. Both Z-stitch and VCD techniques have low complication rates and effectively maintain vascular patency.


Subject(s)
Dog Diseases , Hemostatic Techniques , Postoperative Hemorrhage , Vascular Closure Devices , Vascular Surgical Procedures , Animals , Dogs , Dog Diseases/surgery , Femoral Artery/surgery , Hemostatic Techniques/adverse effects , Hemostatic Techniques/veterinary , Treatment Outcome , Vascular Closure Devices/veterinary , Vascular Closure Devices/adverse effects , Vascular Surgical Procedures/adverse effects , Vascular Surgical Procedures/instrumentation , Vascular Surgical Procedures/methods , Postoperative Hemorrhage/prevention & control , Postoperative Hemorrhage/veterinary
16.
Curr Probl Cardiol ; 49(1 Pt C): 102114, 2024 Jan.
Article in English | MEDLINE | ID: mdl-37802172

ABSTRACT

Femoral access site-related bleeding represent a prognostically impactful issue in interventional cardiology. The impact of a combined use of ultrasound guidance for femoral access and vascular closure device deployment for arteriotomy closure in femoral artery procedures on bleeding complications is still largely unknown. A systematic review was conducted on Pubmed (Medline), Cochrane library and Biomed Central databases between March and April 2023. A total of 9 studies have been selected, of namely 4 registries, 4 prospective studies and one randomized clinical trial. A systematic use of US guidance to access femoral artery resulted feasible and not time consuming, reduced venipuncture and increased first attempt success. Combination of US guidance and deployment of VCD's had the capacity to further decrease vascular and bleeding combination, especially in those patients at a higher risk of post-procedural bleeding. Ultrasound can be easily used during closure device deployment to reduce device failure and major vascular complications.


Subject(s)
Endovascular Procedures , Vascular Closure Devices , Humans , Femoral Artery , Prospective Studies , Feasibility Studies , Vascular Closure Devices/adverse effects , Hemorrhage/etiology , Treatment Outcome , Endovascular Procedures/adverse effects , Endovascular Procedures/methods , Randomized Controlled Trials as Topic
17.
Am J Cardiol ; 209: 181-183, 2023 12 15.
Article in English | MEDLINE | ID: mdl-37863115

ABSTRACT

Suture-mediated closure device and Figure-of-Eight suture are commonly used to achieve hemostasis after use of large bore venous access. Although both methods of closure are commonly used in clinical practice, a head-to-head comparison in a controlled setting has not been performed. Patients presenting to a single center for elective left atrial appendage occlusion or transcatheter edge-to-edge mitral valve repair were randomized to large bore venous closure using the Perclose ProGlide suture-based closure or a Figure-of-Eight suture closure. The patients were followed for 1 month after the procedure. Primary outcome, a composite of access site large ecchymosis, hematoma, infection, pain, need for unscheduled venous ultrasound and need for transfusion, was compared between the 2 arms. A total of 40 patients were randomized in a 1:1 fashion to the 2 venous closure strategies. Baseline characteristics were similar between the 2 groups. Perclose ProGlide arm required use of more devices for hemostasis (1.5 ± 0.5 vs 1 ± 0 respectively, p <0.0001), and there was a significant difference in the cost of closure device ($367.00 ± 122.00 vs $1.00 ± 0 respectively, p <0.001). At 1 month post-procedure, the primary outcome occurred in 4 patients (20%) in the Perclose arm and 7 (35%) patients in the Figure-of-Eight arm, a difference that was not statistically significant (p = 0.48). Time to hemostasis between Figure-of-Eight and Perclose arms did not reach statistical significance (2.5 ± 2.1 vs 3.7 ± 2.3, p = 0.09). In conclusion, both Perclose ProGlide suture-based device and Figure-of-Eight closure are equally feasible and safe for patients who underwent large bore venous access. Figure-of-Eight-based closure is more cost effective.


Subject(s)
Hemostasis, Surgical , Vascular Closure Devices , Humans , Femoral Artery/surgery , Hemostasis , Hemostasis, Surgical/methods , Hemostatic Techniques , Suture Techniques , Sutures , Treatment Outcome , Vascular Surgical Procedures
18.
Am J Crit Care ; 32(6): 421-428, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37907375

ABSTRACT

BACKGROUND: Bed rest duration following deployment of a vascular closure device after transfemoral left-sided cardiac catheterization is not standardized. Despite research supporting reduced bed rest, many hospitals require prolonged bed rest. Delayed ambulation is associated with back pain, urine retention, difficulty eating, and longer stay. OBJECTIVE: To study length of stay, safety, and opportunity cost savings of reduced bed rest at a large urban hospital. METHODS: A single-site 12-week study of 1-hour bed rest after transfemoral cardiac catheterizations using vascular closure devices. Results were compared with historical controls treated similarly. RESULTS: The standard bed rest group included 295 patients (207 male, 88 female; mean [SD] age, 64.4 [8.6] years). The early ambulation group included 260 patients (188 male, 72 female; mean [SD] age, 64 [9.3] years). The groups had no significant difference in age (t634 = 1.18, P = .21) or sex (χ12=0.2, P = .64). Three patients in the standard bed rest group and 1 in the early ambulation group had hematomas (P = .36). The stay for diagnostic cardiac catheterizations was longer in the standard bed rest group (mean [SD], 220.7 [55.2] minutes) than in the early ambulation group (mean [SD], 182.1 [78.5] minutes; t196 = 4.06; P < .001). Stay for percutaneous coronary interventions was longer in the standard bed rest group (mean [SD], 400.2 [50.8] minutes) than in the early ambulation group (mean [SD], 381.6 [54.7] minutes; t262 = 2.86; P = .005). CONCLUSION: Reduced bed rest was safe, shortened stays, and improved efficiency by creating opportunity cost savings.


Subject(s)
Vascular Closure Devices , Humans , Male , Female , Middle Aged , Bed Rest , Cardiac Catheterization , Hematoma , Early Ambulation
19.
Cardiovasc Intervent Radiol ; 46(11): 1553-1561, 2023 Nov.
Article in English | MEDLINE | ID: mdl-37828234

ABSTRACT

PURPOSE: This study aimed to compare a dual Proglide strategy versus a combination of one Proglide and dual Exoseal for large-bore access closure during percutaneous access endovascular aneurysm repair (pEVAR). MATERIALS AND METHODS: We retrospectively analyzed 97 patients who underwent pEVAR at our center between January 2021 and February 2023. The patients were divided into two groups: dual Proglide (P + P) and one Proglide with dual Exoseal (P + E). The primary outcome measures were technical success and access-related vascular complications. Technical success was defined as achieving complete hemostasis without a bailout strategy. Postprocedural follow-up for access-related vascular complications was evaluated at 30 and 60 days using computed tomography angiography and ultrasonography. Severity was graded according to the Cardiovascular Interventional Radiological Society of Europe (CIRSE) Classification. RESULTS: Overall, a dual Proglide strategy was used in 46 patients (47.4%) with 65 groins (46.4%), and a combination of one Proglide and dual Exoseal was used in 51 patients (52.6%) with 75 groins (53.6%). The baseline characteristics were similar between the groups. The total technical success rate was 96.4%, and no significant differences were observed (95.4% vs. 97.3%; p = 0.870). Minor bleeding treatable through compression occurred significantly more often in the P group (CIRSE 1, 10.8% vs. 1.3%, p = 0.042). Hemostasis time, procedural time, length of stay in the hospital, closure device failure, and incidence of unplanned intervention did not differ significantly between the groups. CONCLUSIONS: A combined Proglide and Exoseal strategy is safe and effective for large-bore access closure during pEVAR and can be considered an alternative. However, it should be supported by larger prospective studies.


Subject(s)
Aortic Aneurysm, Abdominal , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Vascular Closure Devices , Humans , Aortic Aneurysm, Abdominal/surgery , Endovascular Aneurysm Repair , Prospective Studies , Retrospective Studies , Treatment Outcome , Hemostasis , Sutures , Femoral Artery/surgery , Hemostatic Techniques
SELECTION OF CITATIONS