Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 422
Filter
1.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 529-534, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752237

ABSTRACT

Objective: To evaluate the safety and effectiveness of applying self-stabilizing zero-profile three-dimensional (3D) printed artificial vertebral bodies in anterior cervical corpectomy and fusion (ACCF) for cervical spondylotic myelopathy. Methods: A retrospective analysis was conducted on 37 patients diagnosed with cervical spondylotic myelopathy who underwent single-level ACCF using either self-stabilizing zero-profile 3D-printed artificial vertebral bodies ( n=15, treatment group) or conventional 3D-printed artificial vertebral bodies with titanium plates ( n=22, control group) between January 2022 and February 2023. There was no significant difference in age, gender, lesion segment, disease duration, and preoperative Japanese Orthopedic Association (JOA) score between the two groups ( P>0.05). Operation time, intraoperative bleeding volume, hospitalization costs, JOA score and improvement rate, incidence of postoperative prosthesis subsidence, and interbody fusion were recorded and compared between the two groups. Results: Compared with the control group, the treatment group had significantly shorter operation time and lower hospitalization costs ( P<0.05); there was no significant difference in intraoperative bleeding volume between the two groups ( P>0.05). All patients were followed up, with a follow-up period of 6-21 months in the treatment group (mean, 13.7 months) and 6-19 months in the control group (mean, 12.7 months). No dysphagia occurred in the treatment group, while 5 cases occurred in the control group, with a significant difference in the incidence of dysphagia between the two groups ( P<0.05). At 12 months after operation, both groups showed improvement in JOA scores compared to preoperative scores, with significant differences ( P<0.05); however, there was no significant difference in the JOA scores and improvement rate between the two groups ( P>0.05). Radiographic examinations showed the interbody fusion in both groups, and the difference in the time of interbody fusion was not significant ( P>0.05). At last follow-up, 2 cases in the treatment group and 3 cases in the control group experienced prosthesis subsidence, with no significant difference in the incidence of prosthesis subsidence ( P>0.05). There was no implant displacement or plate-screw fracture during follow-up. Conclusion: The use of self-stabilizing zero-profile 3D-printed artificial vertebral bodies in the treatment of cervical spondylotic myelopathy not only achieves similar effectiveness to 3D-printed artificial vertebral bodies, but also reduces operation time and the incidence of postoperative dysphagia.


Subject(s)
Cervical Vertebrae , Decompression, Surgical , Printing, Three-Dimensional , Spinal Fusion , Spondylosis , Humans , Spondylosis/surgery , Cervical Vertebrae/surgery , Retrospective Studies , Spinal Fusion/methods , Spinal Fusion/instrumentation , Male , Decompression, Surgical/methods , Female , Treatment Outcome , Bone Plates , Vertebral Body/surgery , Spinal Cord Diseases/surgery , Middle Aged
2.
Zhongguo Xiu Fu Chong Jian Wai Ke Za Zhi ; 38(5): 535-541, 2024 May 15.
Article in Chinese | MEDLINE | ID: mdl-38752238

ABSTRACT

Objective: To evaluate the effectiveness of using titanium alloy trabecular bone three-dimensional (3D) printed artificial vertebral body in treating cervical ossification of the posterior longitudinal ligament (OPLL). Methods: A retrospective analysis was conducted on clinical data from 45 patients with cervical OPLL admitted between September 2019 and August 2021 and meeting the selection criteria. All patients underwent anterior cervical corpectomy and decompression, interbody bone graft fusion, and titanium plate internal fixation. During operation, 21 patients in the study group received titanium alloy trabecular bone 3D printed artificial vertebral bodies, while 24 patients in the control group received titanium cages. There was no significant difference in baseline data such as gender, age, disease duration, affected segments, or preoperative pain visual analogue scale (VAS) score, Japanese Orthopaedic Association (JOA) score, Neck Disability Index (NDI), vertebral height, and C 2-7Cobb angle ( P>0.05). Operation time, intraoperative blood loss, and occurrence of complications were recorded for both groups. Preoperatively and at 3 and 12 months postoperatively, the functionality and symptom relief were assessed using JOA scores, VAS scores, and NDI evaluations. The vertebral height and C 2-7 Cobb angle were detected by imaging examinations and the implant subsidence and intervertebral fusion were observed. Results: The operation time and incidence of complications were significantly lower in the study group than in the control group ( P<0.05), while the difference in intraoperative blood loss between the two groups was not significant ( P>0.05). All patients were followed up 12-18 months, with the follow-up time of (14.28±4.34) months in the study group and (15.23±3.54) months in the control group, showing no significant difference ( t=0.809, P=0.423). The JOA score, VAS score, and NDI of the two groups improved after operation, and further improved at 12 months compared to 3 months, with significant differences ( P<0.05). At each time point, the study group exhibited significantly higher JOA scores and improvement rate compared to the control group ( P<0.05); but there was no significantly difference in VAS score and NDI between the two groups ( P>0.05). Imaging re-examination showed that the vertebral height and C 2-7Cobb angle of the two groups significantly increased at 3 and 12 months after operation ( P<0.05), and there was no significant difference between 3 and 12 months after operation ( P>0.05). At each time point, the vertebral height and C 2-7Cobb angle of the study group were significantly higher than those of the control group ( P<0.05), and the implant subsidence rate was significantly lower than that of the control group ( P<0.05). However, there was no significant difference in intervertebral fusion rate between the two groups ( P>0.05). Conclusion: Compared to traditional titanium cages, the use of titanium alloy trabecular bone 3D-printed artificial vertebral bodies for treating cervical OPLL results in shorter operative time, fewer postoperative complications, and lower implant subsidence rates, making it superior in vertebral reconstruction.


Subject(s)
Alloys , Cervical Vertebrae , Ossification of Posterior Longitudinal Ligament , Printing, Three-Dimensional , Spinal Fusion , Titanium , Humans , Ossification of Posterior Longitudinal Ligament/surgery , Cervical Vertebrae/surgery , Retrospective Studies , Spinal Fusion/methods , Spinal Fusion/instrumentation , Decompression, Surgical/methods , Cancellous Bone , Treatment Outcome , Vertebral Body/surgery , Female , Male , Bone Plates , Middle Aged
3.
J Orthop Surg Res ; 19(1): 234, 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38610023

ABSTRACT

BACKGROUND: Contiguous two-segment cervical disc arthroplasty (CDA) is safe and effective, while post-operative radiographic change is poorly understood. We aimed to clarify the morphological change of the three vertebral bodies operated on. METHODS: Patients admitted between 2015 and 2020 underwent contiguous two-level Prestige LP CDA were included. The follow-up was divided into immediate post-operation (≤ 1 week), early (≤ 6 months), and last follow-up (≥ 12 months). Clinical outcomes were measured by Japanese Orthopedic Association (JOA) score, visual analogue score (VAS), and neck disability index (NDI). Radiographic parameters on lateral radiographs included sagittal area, anterior-posterior diameters (superior, inferior endplate length, and waist length), and anterior and posterior heights. Sagittal parameters included disc angle, Cobb angle, range of motion, T1 slope, and C2-C7 sagittal vertical axis. Heterotopic ossification (HO) and anterior bone loss (ABL) were recorded. RESULTS: 78 patients were included. Clinical outcomes significantly improved. Of the three operation-related vertebrae, only middle vertebra decreased significantly in sagittal area at early follow-up. The four endplates that directly meet implants experienced significant early loss in length. Sagittal parameters were kept within an acceptable range. Both segments had a higher class of HO at last follow-up. More ABL happened to middle vertebra. The incidence and degree of ABL were higher for the endplates on middle vertebra only at early follow-up. CONCLUSION: Our findings indicated that after contiguous two-segment CDA, middle vertebra had a distinguishing morphological changing pattern that could be due to ABL, which deserves careful consideration before and during surgery.


Subject(s)
Bone Diseases, Metabolic , Orthopedics , Humans , Arthroplasty/adverse effects , Spine , Vertebral Body
4.
Clin Biomech (Bristol, Avon) ; 114: 106239, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38599132

ABSTRACT

BACKGROUND: The application of expandable titanium-cages has gained widespread use in vertebral body replacement for indications such as burst fractures, tumors and infectious destruction. However, torque forces necessary for a satisfactory expansion of these implants and for subsidence of them into the adjacent vertebrae are unknown within the osteoporotic spine. METHODS: Six fresh-frozen human, osteoporotic, lumbar spines were dorsally instrumented with titanium implants (L2-L4) and a partial corpectomy of L3 was performed. An expandable titanium-cage was inserted ventrally and expanded by both residents and senior surgeons until fixation was deemed sufficient, based on haptic feedback. Torque forces for expansion were measured in Nm. Expansion was then continued until cage subsidence occurred. Torque forces necessary for subsidence were recorded. Strain of the dorsal rods during expansion was measured with strain gauges. FINDINGS: The mean torque force for fixation of cages was 1.17 Nm (0.9 Nm for residents, 1.4 Nm for senior surgeons, p = .06). The mean torque force for subsidence of cages was 3.1 Nm (p = .005). Mean peak strain of the dorsal rods was 970 µm/m during expansion and 1792 µm/m at subsidence of cages (p = .004). INTERPRETATION: The use of expandable titanium-cages for vertebral body replacement seems to be a primarily safe procedure even within the osteoporotic spine as torque forces required for subsidence of cages are nearly three times higher than those needed for fixation. Most of the expansion load is absorbed by straining of the dorsal instrumentation. Rod materials other than titanium may alter the torque forces found in this study.


Subject(s)
Spinal Fusion , Titanium , Humans , Vertebral Body , Torque , Lumbar Vertebrae/surgery , Prostheses and Implants
5.
World Neurosurg ; 185: e995-e1003, 2024 May.
Article in English | MEDLINE | ID: mdl-38462068

ABSTRACT

BACKGROUND: Butterfly vertebra (BV) is a rare congenital spinal anomaly for which there is a paucity of large-scale retrospective studies and established guidelines for treatment. The objective of this study was to elucidate the clinical characteristics, imaging findings, and therapeutic approaches for BV. METHODS: We conducted a retrospective analysis of 30 patients diagnosed with BV at our hospital from 2009 to 2023, examining clinical data, imaging findings, and clinical interventions. RESULTS: The analysis comprised a cohort of 30 patients, consisting of 15 males and 15 females, with a mean age of 27.63 ± 19.84 years. Imaging studies indicated that the majority of vertebral bodies affected by BV were single-segmented (63.3%, 19/30) and less commonly multi-segmented (36.7%, 11/30). These findings frequently coexisted with other medical conditions, most notably spinal scoliosis (76.7%, 23/30). Furthermore, the study identified a range of spinal abnormalities among patients, including hemivertebral deformity (30.0%, 9/30), spinal cleft (10.0%, 3/30), lumbar disc protrusion or herniation (10.0%, 3/30), vertebral slippage (10.0%, 3/30), thoracic kyphosis deformity (6.67%, 2/30), vertebral fusion deformity (6.67%, 2/30), compressive fractures (3.3%, 1/30), and vertebral developmental anomalies (3.3%, 1/30). Clinical intervention resulted in symptom relief for 23 nonsurgical patients through lifestyle modifications, analgesic use, and physical therapy. Seven surgical patients underwent appropriate surgical procedures, leading to satisfaction and adherence to regular postoperative follow-up appointments. CONCLUSIONS: BV is a rare vertebral anomaly that can be easily misdiagnosed due to its similarity to other diseases. Consequently, it is imperative to enhance vigilance in the differential diagnosis process in order to promptly recognize BV. Furthermore, in cases where patients present with additional associated radiographic findings, a thorough evaluation is typically warranted and timely measures should be taken for treatment.


Subject(s)
Vertebral Body , Humans , Male , Female , Retrospective Studies , Adult , Adolescent , Young Adult , Middle Aged , Child , Child, Preschool , Vertebral Body/surgery , Vertebral Body/diagnostic imaging , Spinal Diseases/surgery , Spinal Diseases/diagnostic imaging , Aged
6.
Med Eng Phys ; 125: 104137, 2024 03.
Article in English | MEDLINE | ID: mdl-38508790

ABSTRACT

Osteoporosis is a common bone disease that often leads to difficulty in vertebrae revision. Traditional pedicle screws are often complicated to operate and have poor visibility during implantation. A new detachable pedicle screw is needed to improve the revision effect. The aim of this study was to design a new detachable pedicle screw based on medical optical imaging to improve the outcome of vertebral revision in osteoporosis, and to improve operational feasibility and visibility. In this study, the parameters related to the degree of osteoporosis were obtained by optical imaging detection of the osteoporotic vertebral body. Then a new detachable pedicle screw was designed according to the test results to improve the effect of vertebral body revision. By preparing and optimizing the material and structure of the screw, it is ensured that it has sufficient mechanical strength and stability. Finally, the visibility and operability of the improved screw during implantation were verified by medical optical imaging. Compared with traditional screws, the new detachable pedicle screw can improve the vertebral body revision in the case of osteoporosis. The optical imaging test results show that the new screw has good visibility and maneuverability, providing more accurate guidance and positioning for the vertebral body revision operation.


Subject(s)
Osteoporosis , Pedicle Screws , Humans , Vertebral Body , Bone Cements , Biomechanical Phenomena , Osteoporosis/diagnostic imaging , Osteoporosis/surgery , Lumbar Vertebrae/surgery
7.
J Pediatr Orthop ; 44(5): e389-e393, 2024.
Article in English | MEDLINE | ID: mdl-38454491

ABSTRACT

INTRODUCTION: Anterior vertebral body tethering (AVBT) is increasingly popular as an option for surgical treatment of idiopathic scoliosis (IS). While the technology remains new, it is important for families and patients to be able to compare it to the current standard of care, posterior spinal fusion (PSF). The purpose of this study is to describe the complication rate of AVBT in IS using the mCDS and to compare it to the recently reported complication rate of PSF in IS. METHODS: A multicenter pediatric spine deformity database was queried for all idiopathic scoliosis patients who underwent vertebral body tethering. There were 171 patients with a minimum 9-month follow-up included in this study. Complications were retrospectively graded by 2 attending pediatric spine surgeons using the mCDS classification system. RESULTS: Data from 171 patients with idiopathic scoliosis was available for analysis, with 156/171 (91%) of patients being female and an average age of 12.2 years old at surgery. There were 156 thoracic tethers (1 with an LIV below L2), 5 lumbar tethers, 9 staged double tethers, and only 1 patient with same-day double tether. Fifty-five (55) (32%) patients experienced a total of 69 complications. The most common complication type for VBT by mCDS was Grade IIIb, encompassing 29/69 (42%) of complications. The second most frequent complication grade was Grade I at 23/69 (33%). Thirty-four (34) out of 69 (49%) of the VBT complications reported required either procedural/surgical intervention or admission to the ICU. CONCLUSIONS: This is the first study to directly compare the complication profile of VBT to PSF using the mCDS. Forty-nine percent (49%) of the VBT complications reported were at least Grade III, while only 7% of complications in the control PSF cohort from the literature were Grade III or higher. The mCDS complication classification brings light to the early learning experience of a new technique compared to the widely accepted standard of PSF for IS. LEVEL OF EVIDENCE: III - Retrospective comparative study.


Subject(s)
Scoliosis , Spinal Fusion , Humans , Female , Child , Male , Scoliosis/surgery , Retrospective Studies , Vertebral Body , Thoracic Vertebrae/surgery , Lumbar Vertebrae/surgery , Treatment Outcome , Spinal Fusion/adverse effects , Spinal Fusion/methods
8.
Front Endocrinol (Lausanne) ; 15: 1352048, 2024.
Article in English | MEDLINE | ID: mdl-38440788

ABSTRACT

Objectives: To quantitatively investigate the age- and sex-related longitudinal changes in trabecular volumetric bone mineral density (vBMD) and vertebral body volume at the thoracolumbar spine in adults. Methods: We retrospectively included 168 adults (mean age 58.7 ± 9.8 years, 51 women) who received ≥7 MDCT scans over a period of ≥6.5 years (mean follow-up 9.0 ± 2.1 years) for clinical reasons. Level-wise vBMD and vertebral body volume were extracted from 22720 thoracolumbar vertebrae using a convolutional neural network (CNN)-based framework with asynchronous calibration and correction of the contrast media phase. Human readers conducted semiquantitative assessment of fracture status and bony degenerations. Results: In the 40-60 years age group, women had a significantly higher trabecular vBMD than men at all thoracolumbar levels (p<0.05 to p<0.001). Conversely, men, on average, had larger vertebrae with lower vBMD. This sex difference in vBMD did not persist in the 60-80 years age group. While the lumbar (T12-L5) vBMD slopes in women only showed a non-significant trend of accelerated decline with age, vertebrae T1-11 displayed a distinct pattern, with women demonstrating a significantly accelerated decline compared to men (p<0.01 to p<0.0001). Between baseline and last follow-up examinations, the vertebral body volume slightly increased in women (T1-12: 1.1 ± 1.0 cm3; L1-5: 1.0 ± 1.4 cm3) and men (T1-12: 1.2 ± 1.3 cm3; L1-5: 1.5 ± 1.6 cm3). After excluding vertebrae with bony degenerations, the residual increase was only small in women (T1-12: 0.6 ± 0.6 cm3; L1-5: 0.7 ± 0.7 cm3) and men (T1-12: 0.7 ± 0.6 cm3; L1-5: 1.2 ± 0.8 cm3). In non-degenerated vertebrae, the mean change in volume was <5% of the respective vertebral body volumes. Conclusion: Sex differences in thoracolumbar vBMD were apparent before menopause, and disappeared after menopause, likely attributable to an accelerated and more profound vBMD decline in women at the thoracic spine. In patients without advanced spine degeneration, the overall volumetric changes in the vertebral body appeared subtle.


Subject(s)
Sex Characteristics , Vertebral Body , Adult , Female , Humans , Male , Middle Aged , Aged , Bone Density , Retrospective Studies , Spine
9.
Acta Neurochir (Wien) ; 166(1): 143, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38509395

ABSTRACT

BACKGROUND: To investigate the incidence and risk factors of coronal vertical vertebral body fracture (CV-VBF) during lateral lumbar interbody fusion (LLIF) for degenerative lumbar disease. METHODS: Clinical data, including age, sex, body mass index, and bone mineral density, were reviewed. Radiological assessments, such as facet joint arthrosis, intervertebral disc motion, index disc height, and cage profiles, were conducted. Posterior instrumentation was performed using either a single or staged procedure after LLIF. Demographic and surgical data were compared between patients with and without VBF. RESULTS: Out of 273 patients (552 levels), 7 (2.6%) experienced CV-VBF. Among the 552 levels, VBF occured in 7 levels (1.3%). All VBF cases developed intraoperatively during LLIF, with no instances caused by cage subsidence during the follow-up period. Sagittal motion in segments adjacent to VBF was smaller than in others (4.6° ± 2.6° versus 6.5° ± 3.9°, P = 0.031). The average grade of facet arthrosis was 2.5 ± 0.7, indicating severe facet arthrosis. All fractures developed due to oblique placement of a trial or cage into the index disc space, leading to a nutcracker effect. These factors were not related to bone quality. CONCLUSIONS: CV-VBF after LLIF occurred in 2.6% of patients, accounting for 1.3% of all LLIF levels. A potential risk factor for VBF involves the nutcracker-impinging effect due to the oblique placement of a cage. Thorough preoperative evaluations and surgical procedures are needed to avoid VBF when considering LLIF in patients with less mobile spine.


Subject(s)
Osteoarthritis , Skull Fractures , Spinal Fusion , Humans , Vertebral Body , Retrospective Studies , Risk Factors , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Spinal Fusion/methods , Osteoarthritis/etiology , Treatment Outcome
10.
Arch Osteoporos ; 19(1): 19, 2024 Mar 21.
Article in English | MEDLINE | ID: mdl-38512565

ABSTRACT

This retrospective study compared the efficacy of anabolic agents (romosozumab and teriparatide) with that of alendronate in preventing subsequent vertebral body fractures (SVBFs) after balloon kyphoplasty (BKP). All anabolic agents significantly reduced SVBFs. Romosozumab was most effective in increasing bone mineral density (BMD) and completely suppressed distant vertebral body fractures. INTRODUCTION: To determine optimal anti-osteoporosis medications, we compared romosozumab and teriparatide to alendronate as a control from perioperative BKP to the 1st postoperative year for treatment and secondary fracture prevention in osteoporosis. METHODS: A total of 603 patients who underwent initial BKP for osteoporotic vertebral fractures were evaluated and categorized into five groups based on drug administration: romosozumab (group R, 155 patients), twice-weekly teriparatide (group TW, 48), weekly teriparatide (group W, 151), daily teriparatide (group D, 138), and alendronate (control) (group C, 111). The 1-year incidence of SVBFs, BMD change rate, and probability of requiring BKP were compared among the groups. RESULTS: SVBF incidence was 3.9%, 6.5%, 8.3%, 6.0%, and 14.4% in groups R, D, TW, W, and C, respectively, with all other groups exhibiting significantly lower rates than group C. The groups that administered the anabolic agents had a notably lower incidence of distant fractures than group C. Compared with group C, group R showed significantly higher BMD change rates in lumbar vertebral bodies at 4, 8, and 12 months and group D at 12 months. Anabolic agent groups exhibited significantly higher improvement rates than group C after conservative treatment alone. CONCLUSION: The anabolic agents were found to be more effective at reducing the incidence of SVBF (especially distant vertebral fractures) than alendronate. These agents decreased the rate of repeat BKP even after the occurrence of a fracture. Overall, the use of an anabolic agent for the treatment of osteoporosis after BKP is better than the use of alendronate, even when treatment is initiated in the perioperative stage.


Subject(s)
Anabolic Agents , Bone Density Conservation Agents , Fractures, Compression , Kyphoplasty , Osteoporosis , Osteoporotic Fractures , Spinal Fractures , Humans , Vertebral Body , Teriparatide/therapeutic use , Alendronate/therapeutic use , Retrospective Studies , Anabolic Agents/pharmacology , Anabolic Agents/therapeutic use , Osteoporosis/drug therapy , Osteoporosis/complications , Osteoporotic Fractures/therapy , Bone Density , Spinal Fractures/complications , Fractures, Compression/surgery , Bone Density Conservation Agents/therapeutic use , Bone Density Conservation Agents/pharmacology
11.
Spine Deform ; 12(3): 663-670, 2024 May.
Article in English | MEDLINE | ID: mdl-38340229

ABSTRACT

INTRODUCTION: The addition of the L4 "AR" and "AL" lumbar modifier for Lenke 1A idiopathic scoliosis (IS) has been shown to direct treatment in posterior spinal fusion; however, its utility in vertebral body tethering (VBT) has yet to be evaluated. METHODS: A review of a prospective, multicenter database for VBT in IS was performed for patients with Lenke 1A deformities and a minimum of 2 years follow-up. Patients were categorized by their lumbar modifier (AR vs AL). Less optimal VBT outcome (LOVO) was defined as a final coronal curve > 35°, lumbar adding-on, or revision surgery for deformity progression or adding-on. RESULTS: Ninety-nine patients met inclusion criteria (81% female, mean 12.6 years), with 55.6% being AL curves. Overall, there were 23 instances of tether breakage (23.3%) and 20 instances of LOVO (20.2%). There was a higher rate of LOVO in AR curves (31.8% vs 10.9%, P = 0.01). Patients with LOVO had greater preoperative deformity, greater apical translation, larger coronal deformity on first erect radiographs, and less coronal deformity correction. Failure to correct the deformity < 30° on first erect was associated with LOVO, as was LIV selection short of the last touch vertebra (TV). Independent risk factors for LOVO included AR curves (OR 3.4; P = 0.04) and first erect curve magnitudes > 30 degrees (OR 6.0; P = 0.002). DISCUSSION: There is a 20.2% rate of less optimal VBT following VBT for Lenke 1A curves. AR curves are independently predictive of less optimal outcomes following VBT and require close attention to LIV selection. Surgeons should consider achieving an initial coronal correction < 30 degrees and extending the LIV to at least the TV to minimize the risk of LOVO.


Subject(s)
Lumbar Vertebrae , Scoliosis , Spinal Fusion , Humans , Scoliosis/surgery , Scoliosis/diagnostic imaging , Female , Male , Lumbar Vertebrae/surgery , Lumbar Vertebrae/diagnostic imaging , Child , Spinal Fusion/methods , Treatment Outcome , Adolescent , Vertebral Body/surgery , Vertebral Body/diagnostic imaging , Prospective Studies , Follow-Up Studies , Radiography
12.
Beijing Da Xue Xue Bao Yi Xue Ban ; 56(1): 161-166, 2024 Feb 18.
Article in Chinese | MEDLINE | ID: mdl-38318912

ABSTRACT

OBJECTIVE: To explore the short-term outcomes of 3D-printing stand-alone artificial vertebral body (AVB) in the surgical procedure of anterior cervical corpectomy and fusion (ACCF). METHODS: Following the proposal of IDEAL (idea, development, exploration, assessment, and long-term follow-up) framework, we designed and conducted this single-armed, retrospective cohort study. The patients with cervical spondylotic myelopathy were recruited, and these patients exclusively received the surgical procedure of single-level ACCF in our single center. After the process of corpectomy, the size was tailored using different trials and the most suitable stand-alone AVB was then implanted. This AVB was manufactured by the fashion of 3D-printing. Two pairs of screws were inserted in an inclined way into the adjacent vertebral bodies, to stabilize the AVB. The participants were regularly followed-up after the operation. Their clinical data were thoroughly reviewed. We assessed the neurological status according to Japanese Orthopedic Association (JOA) scale. We determined the fusion based on imaging examination six months after the operation. The recorded clinical data were analyzed using specific software and they presented in suitable styles. Paired t test was employed in comparison analysis. RESULTS: In total, there were eleven patients being recruited eventually. The patients were all followed up over six months after the operation. The mean age of the cohort was (57.2±10.2) years. The mean operation time was (76.1±23.1) min and the median bleeding volume was 150 (100, 200) mL. The postoperative course was uneventful for all the cases. Dysphagia, emergent hematoma, and deterioration of neurological function did not occur. Mean JOA scores were 13.2±2.2 before the operation and 16.3±0.8 at the final follow-up, which were significantly different (P < 0.001). The mean recovery rate of neurological function was 85.9%. By comparing the imaging examinations postoperatively and six months after the operation, we found that the average subsidence length was (1.2±1.1) mm, and that there was only one cases (9.1%) of the severe subsidence (>3 mm). We observed significant improvement of cervical lordosis after the operation (P=0.013). All the cases obtained solid fusion. CONCLUSION: 3D-printing stand-alone AVB presented favorable short-term outcome in one-level ACCF in this study. The fusion rate of this zero-profile prosthesis was satisfactory and the complication rate was relatively low.


Subject(s)
Spinal Cord Diseases , Spinal Fusion , Spondylosis , Humans , Middle Aged , Aged , Vertebral Body , Retrospective Studies , Treatment Outcome , Spondylosis/surgery , Spinal Cord Diseases/surgery , Printing, Three-Dimensional , Cervical Vertebrae/surgery , Spinal Fusion/methods
13.
J Morphol ; 285(2): e21666, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38361265

ABSTRACT

Vertebral growth is an essential developmental process to support the expansion of the vertebrate body. In teleosts, the lateral side of the vertebral bodies develops to form different structures among species in the late stages of vertebral growth, although lateral structures are not apparent in the early stages. Lateral structures are one of the structural features that determine the diversity of teleost vertebrae. However, explanations for the formation of lateral structures are conflicting because few reports have investigated the growth of teleost vertebral bodies. To clarify the growth process, we analyzed the morphological changes in the vertebral body of Pacific bluefin tuna Thunnus orientalis at different developmental stages using micro-computed tomography (CT) scans. The micro-CT scans showed that the vertebral centrum formed a plate-like ridge on the lateral side along the cranial-caudal direction and extended laterally with increasing thickness. Simultaneously, the proximal region of the lateral ridges became porous as the vertebrae grew to form bone marrow cavities. Furthermore, we used histological observations to describe the relationship between these morphological changes and osteoblast and osteoclast activities. Osteoblasts accumulated on the distal edges of the lateral ridges, whereas osteoclasts were distributed in the bone marrow cavities. These observations suggest that bone resorption occurs proximally to form bone marrow cavities in addition to bone synthesis at the edges of the lateral ridges. The bone marrow cavities were occupied by blood vessels, extracellular matrix, and adipocytes, and the internal tissue composition changed to increase the area of adipose tissue. Because the ratio of bone volume decreases in large vertebrae, bone formation and resorption are regulated to separate the external cortical and internal trabecular bones to support the vertebrae. This study is the first to report the formation of lateral structures and can be applied to similar lateral structures in the vertebrae of other teleost species.


Subject(s)
Tuna , Vertebral Body , Animals , X-Ray Microtomography , Spine/diagnostic imaging , Bone and Bones
14.
Sci Rep ; 14(1): 3341, 2024 02 09.
Article in English | MEDLINE | ID: mdl-38336974

ABSTRACT

Accurate annotation of vertebral bodies is crucial for automating the analysis of spinal X-ray images. However, manual annotation of these structures is a laborious and costly process due to their complex nature, including small sizes and varying shapes. To address this challenge and expedite the annotation process, we propose an ensemble pipeline called VertXNet. This pipeline currently combines two segmentation mechanisms, semantic segmentation using U-Net, and instance segmentation using Mask R-CNN, to automatically segment and label vertebral bodies in lateral cervical and lumbar spinal X-ray images. VertXNet enhances its effectiveness by adopting a rule-based strategy (termed the ensemble rule) for effectively combining segmentation outcomes from U-Net and Mask R-CNN. It determines vertebral body labels by recognizing specific reference vertebral instances, such as cervical vertebra 2 ('C2') in cervical spine X-rays and sacral vertebra 1 ('S1') in lumbar spine X-rays. Those references are commonly relatively easy to identify at the edge of the spine. To assess the performance of our proposed pipeline, we conducted evaluations on three spinal X-ray datasets, including two in-house datasets and one publicly available dataset. The ground truth annotations were provided by radiologists for comparison. Our experimental results have shown that the proposed pipeline outperformed two state-of-the-art (SOTA) segmentation models on our test dataset with a mean Dice of 0.90, vs. a mean Dice of 0.73 for Mask R-CNN and 0.72 for U-Net. We also demonstrated that VertXNet is a modular pipeline that enables using other SOTA model, like nnU-Net to further improve its performance. Furthermore, to evaluate the generalization ability of VertXNet on spinal X-rays, we directly tested the pre-trained pipeline on two additional datasets. A consistently strong performance was observed, with mean Dice coefficients of 0.89 and 0.88, respectively. In summary, VertXNet demonstrated significantly improved performance in vertebral body segmentation and labeling for spinal X-ray imaging. Its robustness and generalization were presented through the evaluation of both in-house clinical trial data and publicly available datasets.


Subject(s)
Tomography, X-Ray Computed , Vertebral Body , Tomography, X-Ray Computed/methods , X-Rays , Radiography , Cervical Vertebrae/diagnostic imaging , Image Processing, Computer-Assisted/methods
15.
Acta Biomater ; 177: 300-315, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38340886

ABSTRACT

The vertebral centra of sharks consist of cartilage, and many species' centra contain a bioapatite related to that in bone. Centra microarchitectures at the 0.5-50 µm scale do not appear to have been described previously. This study examines centrum microarchitecture in lamniform and carcharhiniform sharks with synchrotron microComputed Tomography (microCT), scanning electron microscopy and spectroscopy and light microscopy. The analysis centers on the blue shark (carcharhiniform) and shortfin mako (lamniform), species studied with all three modalities. Synchrotron microCT results from seven other species complete the report. The main centrum structures, the corpus calcareum and intermedialia, consist of fine, closely-spaced, mineralized trabeculae whose mean thicknesses and spacings range from 4.5 to 11.2 µm and 4.5 to 15.6 µm, respectively. A significant (p = 0.00001) positive linear relationship between and exists for multiple positions within one mako centrum. Carcharhiniform species' and exhibit an inverse linear relationship (p = 0.005) while in lamniforms these variables tend toward a positive relationship which does not reach statistical significance (p = 0.099). In all species, the trabeculae form an uninterrupted, interconnected network, and the unmineralized volumes are similarly interconnected. Small differences in mineralization level are observed in trabeculae. Centrum growth band pairs are found to consist of locally higher /lower mineral volume fraction. Within the intermedialia, radial canals and radial microrods were characterized, and compacted trabeculae are prominent in the mako intermedialia. The centra's mineralized central zones were non-trabecular and are also described. STATEMENT OF SIGNIFICANCE: This study's novel result is the demonstration that the mineralized cartilage of sharks' vertebral bodies (centra) consists of a fine 3D array of interconnected plates (trabeculae) and an interpenetrating network of unmineralized tissue. This microstructure is radically different from that in tesserae or in teeth, the other main mineralized shark tissues. Using volumetric synchrotron microComputed Tomography, numerical values of mean trabecular thickness and spacing and their relationship were measured for nine species. Scanning electron microscopy added a higher resolution view of the microstructures, and histology provided complementary information on cartilage and cells. The present results suggest centra microstructure helps accommodate the very large in vivo strains and may prevent damage accumulation during millions of cycles of swimming-induced loading.


Subject(s)
Sharks , Tooth , Animals , Vertebral Body , X-Ray Microtomography , Bone and Bones
17.
BMC Musculoskelet Disord ; 25(1): 161, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38378495

ABSTRACT

BACKGROUND: Percutaneous transforaminal endoscopic decompression (PTED) is an ideal minimally invasive decompression technique for the treatment of lumbar spinal stenosis (LSS) with degenerative lumbar spondylolisthesis (DLS). The posterosuperior region underneath the slipping vertebral body (PRSVB) formed by DLS is an important factor exacerbating LSS in patients. Therefore, the necessity of removing the PRSVB during ventral decompression remains to be discussed. This study aimed to describe the procedure of PTED combined with the removal of the PRSVB and to evaluate the clinical outcomes. METHODS: LSS with DLS was diagnosed in 44 consecutive patients at our institution from January 2019 to July 2021, and they underwent PTED combined with the removal of the PRSVB. All patients were followed up for at least 12 months. The clinical outcomes were evaluated using the visual analog scale (VAS), Oswestry Disability Index (ODI), and modified MacNab criteria. RESULTS: The mean age of the patients was 69.5 ± 7.1 years. The mean preoperative ODI score, VAS score of the low back, and VAS score of the leg were 68.3 ± 10.8, 5.8 ± 1.0, and 7.7 ± 1.1, respectively, which improved to 18.8 ± 5.0, 1.4 ± 0.8, and 1.6 ± 0.7, respectively, at 12 months postoperatively. The proportion of patients presenting "good" and "excellent" ratings according to the modified MacNab criteria was 93.2%. The percent slippage in spondylolisthesis preoperatively (16.0% ± 3.3%) and at the end of follow-up (15.8% ± 3.3%) did not differ significantly (p>0.05). One patient had a dural tear, and one patient had postoperative dysesthesia. CONCLUSIONS: Increasing the removal of PRSVB during the PTED process may be a beneficial surgical procedure for alleviating clinical symptoms in patients with LSS and DLS. However, long-term follow-up is needed to study clinical effects.


Subject(s)
Spinal Stenosis , Spondylolisthesis , Humans , Middle Aged , Aged , Spinal Stenosis/diagnostic imaging , Spinal Stenosis/surgery , Decompression, Surgical/methods , Retrospective Studies , Spondylolisthesis/complications , Spondylolisthesis/diagnostic imaging , Spondylolisthesis/surgery , Vertebral Body/surgery , Lumbar Vertebrae/diagnostic imaging , Lumbar Vertebrae/surgery , Treatment Outcome
18.
Eur J Radiol ; 173: 111364, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38364589

ABSTRACT

PURPOSE: We developed and tested a neural network for automated detection and stability analysis of vertebral body fractures on computed tomography (CT). MATERIALS AND METHODS: 257 patients who underwent CT were included in this Institutional Review Board (IRB) approved study. 463 fractured and 1883 non-fractured vertebral bodies were included, with 190 fractures unstable. Two readers identified vertebral body fractures and assessed their stability. A combination of a Hierarchical Convolutional Neural Network (hNet) and a fracture Classification Network (fNet) was used to build a neural network for the automated detection and stability analysis of vertebral body fractures on CT. Two final test settings were chosen: one with vertebral body levels C1/2 included and one where they were excluded. RESULTS: The mean age of the patients was 68 ± 14 years. 140 patients were female. The network showed a slightly higher diagnostic performance when excluding C1/2. Accordingly, the network was able to distinguish fractured and non-fractured vertebral bodies with a sensitivity of 75.8 % and a specificity of 80.3 %. Additionally, the network determined the stability of the vertebral bodies with a sensitivity of 88.4 % and a specificity of 80.3 %. The AUC was 87 % and 91 % for fracture detection and stability analysis, respectively. The sensitivity of our network in indicating the presence of at least one fracture / one unstable fracture within the whole spine achieved values of 78.7 % and 97.2 %, respectively, when excluding C1/2. CONCLUSION: The developed neural network can automatically detect vertebral body fractures and evaluate their stability concurrently with a high diagnostic performance.


Subject(s)
Spinal Fractures , Vertebral Body , Humans , Female , Middle Aged , Aged , Aged, 80 and over , Male , Retrospective Studies , Spine , Spinal Fractures/diagnostic imaging , Tomography, X-Ray Computed/methods , Artificial Intelligence
19.
Zhonghua Yi Xue Za Zhi ; 104(7): 526-532, 2024 Feb 20.
Article in Chinese | MEDLINE | ID: mdl-38317365

ABSTRACT

Objective: To observe the clinical efficacy of a 3D printed self-stable zero-profile artificial vertebral body for anterior cervical corpectomy decompression and fusion in the treatment of ossification of the posterior longitudinal ligament (OPLL) of the cervical spine. Methods: In this prospective randomized controlled trial, patients diagnosed with OPLL in Luohe Central Hospital from January to July 2022 were divided into a zero-profile group (3D printed self-stable zero-profile artificial vertebral body was used for internal fixation and fusion after anterior cervical subtotal decompression,) and titanium-mesh group (titanium-mesh and titanium plate were used for internal fixation and fusion after anterior cervical subtotal decompression) according to envelope random method. Operation time, intraoperative blood loss, Japanese Orthopaedic Association (JOA) score and improvement rate, incidence of postoperative prosthesis subsidence, and bone graft fusion were recorded and compared between the two groups. Results: Finally, 21 patients in the zero notch group and 20 patients in the titanium mesh group were included in the study and were followed-up. In the zero-profile group, there were 16 males and 5 females, aged (48.0±12.7) years. In the titanium-mesh group, there were 14 males and 6 females, aged (49.8±10.2) years. All the 41 patients successfully completed the operation. In the zero-profile group, the surgical time was (50.04±8.45) minutes, the blood loss was (95.38±26.07) ml and the hospitalization cost was (42.32±6.12) thousand yuan. In the titanium-mesh group, the surgical time was (59.20±11.95) minutes, the blood loss was (93.10±27.86) ml and the hospitalization cost was (42.10±6.71) thousand yuan. The surgical time in the zero-profile group was shorter than that in the titanium-mesh group (P=0.007), and there was no statistically significant difference in blood loss and hospitalization costs between the two groups (both P>0.05). The 41 patients were followed-up for (14.29±1.45) months. Four cases (20.0%) in the titanium mesh group experienced swallowing difficulties and 0 cases in the zero incision group, the difference between the two groups was statistically significant (P=0.048). No intraoperative hematoma, spinal cord nerve recompression, airway crisis, incision infection complications, and no steel plate or screw breakage or displacement occurred after surgery. At the last follow-up, all cases had bone fusion. At the follow-up of 12 months after surgery, the JOA score of the zero incision group increased from preoperative (10.33±1.71) points to (15.47±0.81) points, with an improvement rate of 76.1%±15.7%; the JOA score of the titanium mesh group increased from (10.30±1.75) points to (15.30±0.92) points, with an improvement rate of 73.2%±16.7%; there was no statistically significant difference in improvement rate between the two groups (P=0.580). At the follow-up of 12 months after surgery, 1 case (4.8%) in the zero incision group and 8 cases (40.0%) in the titanium mesh group experienced implant sinking, and the difference between the two groups was statistically significant (P=0.009). Conclusion: Compared with titanium-mesh, 3D printed self-stable zero-profile artificial vertebral body for the treatment of OPLL of the cervical spine can achieve good surgical efficacy, shorter surgical time, lower incidence of postoperative chronic swallowing discomfort, and can provide a better bone material bonding interface and be less prone to prosthesis settlement.


Subject(s)
Ossification of Posterior Longitudinal Ligament , Spinal Fusion , Male , Female , Humans , Longitudinal Ligaments , Titanium , Osteogenesis , Prospective Studies , Vertebral Body , Cervical Vertebrae/surgery , Treatment Outcome , Spinal Fusion/methods , Printing, Three-Dimensional , Retrospective Studies , Ossification of Posterior Longitudinal Ligament/surgery
20.
Comput Biol Med ; 170: 108019, 2024 Mar.
Article in English | MEDLINE | ID: mdl-38325217

ABSTRACT

BACKGROUND: Disuse is a typical phenotype of osteoporosis, but the underlying mechanism has yet to be identified in elderly patients. Disc collapse and intervertebral disc (IVD) fibrosis are two main pathological changes in IVD degeneration (IDD) progression, given that these changes affect load transmission patterns, which may lead to disuse osteoporosis of vertebral bodies and zygapophyseal joint (ZJ) osteoarthritis (ZJOA) biomechanically. METHODS: Clinical data from 59 patients were collected retrospectively. Patient vertebral bony density, ZJOA grade, and disc collapse status were judged via CT. The IVD fibrosis grade was determined based on the FA measurements. Regression analyses identified potential independent risk factors for osteoporosis and ZJOA. L4-L5 numerical models with and without disc collapse and IVD fibrosis were constructed; stress distributions on the bony endplate (BEP) and zygapophyseal joint (ZJ) cartilages were computed in models with and without disc collapse and IVD fibrosis. RESULTS: A significantly lower disc height ratio and significantly greater FA were recorded in patients with ZJOA. A significant correlation was observed between lower HU values and two parameters related to IDD progression. These factors were also proven to be independent risk factors for both osteoporosis and ZJOA. Correspondingly, compared to the intact model without IDD. Lower stress on vertebral bodies and greater stress on ZJOA can be simultaneously recorded in models of disc collapse and IVD fibrosis. CONCLUSIONS: IVD fibrosis and disc collapse simultaneously aggravate vertebral body disuse osteoporosis and ZJOA by posteriorly shifting the load transmission pattern.


Subject(s)
Intervertebral Disc Degeneration , Intervertebral Disc , Osteoarthritis , Osteoporosis , Zygapophyseal Joint , Humans , Aged , Vertebral Body/pathology , Retrospective Studies , Zygapophyseal Joint/diagnostic imaging , Intervertebral Disc/diagnostic imaging , Intervertebral Disc Degeneration/diagnostic imaging , Intervertebral Disc Degeneration/pathology , Osteoarthritis/diagnostic imaging , Osteoporosis/diagnostic imaging , Fibrosis , Lumbar Vertebrae/pathology
SELECTION OF CITATIONS
SEARCH DETAIL
...