Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 1.364
Filter
1.
PLoS One ; 19(5): e0302634, 2024.
Article in English | MEDLINE | ID: mdl-38718001

ABSTRACT

In this paper, a new microstrip triplexer is designed to work at 2.5 GHz, 4.4 GHz and 6 GHz for mid-band 5G applications. All channels are flat with three low group delays (GDs) of 0.84 ns, 0.75 ns and 0.49 ns, respectively. Compared to the previously reported works, the proposed triplexer has the minimum group delay. The designed triplexer has 18.2%, 13.7%, 23.6% fractional bandwidths (FBW%) at 2.5 GHz, 4.4 GHz and 6 GHz, respectively. The obtained insertion losses (ILs) are low at all channels. These features are obtained without a noticeable increase in the overall size. A novel and simple resonator is used to design the proposed triplexer, which includes two pairs of coupled lines combined with a shunt stub. A perfect mathematical analysis is performed to find the resonator behavior and the layout optimization. The type of shunt stub is determined mathematically. Also, the smallness or largeness of some important physical dimensions is determined using the proposed mathematical analysis. Finally, the designed triplexer is fabricated and measured, where the measurement results verify the simulations.


Subject(s)
Equipment Design , Wireless Technology , Wireless Technology/instrumentation
2.
Curr Opin Crit Care ; 30(3): 275-282, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38690957

ABSTRACT

PURPOSE OF REVIEW: Wearable wireless sensors for continuous vital signs monitoring (CVSM) offer the potential for early identification of patient deterioration, especially in low-intensity care settings like general wards. This study aims to review advances in wearable CVSM - with a focus on the general ward - highlighting the technological characteristics of CVSM systems, user perspectives and impact on patient outcomes by exploring recent evidence. RECENT FINDINGS: The accuracy of wearable sensors measuring vital signs exhibits variability, especially notable in ambulatory patients within hospital settings, and standard validation protocols are lacking. Usability of CMVS systems is critical for nurses and patients, highlighting the need for easy-to-use wearable sensors, and expansion of the number of measured vital signs. Current software systems lack integration with hospital IT infrastructures and workflow automation. Imperative enhancements involve nurse-friendly, less intrusive alarm strategies, and advanced decision support systems. Despite observed reductions in ICU admissions and Rapid Response Team calls, the impact on patient outcomes lacks robust statistical significance. SUMMARY: Widespread implementation of CVSM systems on the general ward and potentially outside the hospital seems inevitable. Despite the theoretical benefits of CVSM systems in improving clinical outcomes, and supporting nursing care by optimizing clinical workflow efficiency, the demonstrated effects in clinical practice are mixed. This review highlights the existing challenges related to data quality, usability, implementation, integration, interpretation, and user perspectives, as well as the need for robust evidence to support their impact on patient outcomes, workflow and cost-effectiveness.


Subject(s)
Vital Signs , Wearable Electronic Devices , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Wireless Technology/instrumentation
3.
ACS Nano ; 18(19): 12210-12224, 2024 May 14.
Article in English | MEDLINE | ID: mdl-38695533

ABSTRACT

Accurate postoperative assessment of varying mechanical properties is crucial for customizing patient-specific treatments and optimizing rehabilitation strategies following Achilles tendon (AT) rupture and reconstruction surgery. This study introduces a wireless, chip-less, and immune-tolerant in vivo strain-sensing suture designed to continuously monitor mechanical stiffness variations in the reconstructed AT throughout the healing process. This innovative sensing suture integrates a standard medical suturing thread with a wireless fiber strain-sensing system, which incorporates a fiber strain sensor and a double-layered inductive coil for wireless readout. The winding design of Au nanoparticle-based fiber electrodes and a hollow core contribute to the fiber strain sensor's high sensitivity (factor of 6.2 and 15.1 pF for revised sensitivity), negligible hysteresis, and durability over 10,000 stretching cycles. To ensure biocompatibility and immune tolerance during extended in vivo periods, an antibiofouling lubricant layer was applied to the sensing suture. Using this sensing system, we successfully monitored the strain responses of the reconstructed AT in an in vivo porcine model. This facilitated the postoperative assessment of mechanical stiffness variations through a well-established analytical model during the healing period.


Subject(s)
Biocompatible Materials , Sutures , Wireless Technology , Wireless Technology/instrumentation , Animals , Swine , Biocompatible Materials/chemistry , Biocompatible Materials/pharmacology , Achilles Tendon , Gold/chemistry , Metal Nanoparticles/chemistry
4.
Sensors (Basel) ; 24(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38732871

ABSTRACT

Myoelectric hands are beneficial tools in the daily activities of people with upper-limb deficiencies. Because traditional myoelectric hands rely on detecting muscle activity in residual limbs, they are not suitable for individuals with short stumps or paralyzed limbs. Therefore, we developed a novel electric prosthetic hand that functions without myoelectricity, utilizing wearable wireless sensor technology for control. As a preliminary evaluation, our prototype hand with wireless button sensors was compared with a conventional myoelectric hand (Ottobock). Ten healthy therapists were enrolled in this study. The hands were fixed to their forearms, myoelectric hand muscle activity sensors were attached to the wrist extensor and flexor muscles, and wireless button sensors for the prostheses were attached to each user's trunk. Clinical evaluations were performed using the Simple Test for Evaluating Hand Function and the Action Research Arm Test. The fatigue degree was evaluated using the modified Borg scale before and after the tests. While no statistically significant differences were observed between the two hands across the tests, the change in the Borg scale was notably smaller for our prosthetic hand (p = 0.045). Compared with the Ottobock hand, the proposed hand prosthesis has potential for widespread applications in people with upper-limb deficiencies.


Subject(s)
Artificial Limbs , Hand , Wearable Electronic Devices , Wireless Technology , Humans , Hand/physiology , Pilot Projects , Wireless Technology/instrumentation , Male , Adult , Female , Electromyography/instrumentation , Prosthesis Design
5.
Sensors (Basel) ; 24(9)2024 Apr 26.
Article in English | MEDLINE | ID: mdl-38732888

ABSTRACT

In today's health-monitoring applications, there is a growing demand for wireless and wearable acquisition platforms capable of simultaneously gathering multiple bio-signals from multiple body areas. These systems require well-structured software architectures, both to keep different wireless sensing nodes synchronized each other and to flush collected data towards an external gateway. This paper presents a quantitative analysis aimed at validating both the wireless synchronization task (implemented with a custom protocol) and the data transmission task (implemented with the BLE protocol) in a prototype wearable monitoring platform. We evaluated seven frequencies for exchanging synchronization packets (10 Hz, 20 Hz, 30 Hz, 40 Hz, 50 Hz, 60 Hz, 70 Hz) as well as two different BLE configurations (with and without the implementation of a dynamic adaptation of the BLE Connection Interval parameter). Additionally, we tested BLE data transmission performance in five different use case scenarios. As a result, we achieved the optimal performance in the synchronization task (1.18 ticks as median synchronization delay with a Min-Max range of 1.60 ticks and an Interquartile range (IQR) of 0.42 ticks) when exploiting a synchronization frequency of 40 Hz and the dynamic adaptation of the Connection Interval. Moreover, BLE data transmission proved to be significantly more efficient with shorter distances between the communicating nodes, growing worse by 30.5% beyond 8 m. In summary, this study suggests the best-performing network configurations to enhance the synchronization task of the prototype platform under analysis, as well as quantitative details on the best placement of data collectors.


Subject(s)
Wearable Electronic Devices , Wireless Technology , Wireless Technology/instrumentation , Humans , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Computer Communication Networks/instrumentation , Software
6.
Sensors (Basel) ; 24(9)2024 May 06.
Article in English | MEDLINE | ID: mdl-38733050

ABSTRACT

Gait phase monitoring wearable sensors play a crucial role in assessing both health and athletic performance, offering valuable insights into an individual's gait pattern. In this study, we introduced a simple and cost-effective capacitive gait sensor manufacturing approach, utilizing a micropatterned polydimethylsiloxane dielectric layer placed between screen-printed silver electrodes. The sensor demonstrated inherent stretchability and durability, even when the electrode was bent at a 45-degree angle, it maintained an electrode resistance of approximately 3 Ω. This feature is particularly advantageous for gait monitoring applications. Furthermore, the fabricated flexible capacitive pressure sensor exhibited higher sensitivity and linearity at both low and high pressure and displayed very good stability. Notably, the sensors demonstrated rapid response and recovery times for both under low and high pressure. To further explore the capabilities of these new sensors, they were successfully tested as insole-type pressure sensors for real-time gait signal monitoring. The sensors displayed a well-balanced combination of sensitivity and response time, making them well-suited for gait analysis. Beyond gait analysis, the proposed sensor holds the potential for a wide range of applications within biomedical, sports, and commercial systems where soft and conformable sensors are preferred.


Subject(s)
Gait , Pressure , Wearable Electronic Devices , Wireless Technology , Humans , Gait/physiology , Wireless Technology/instrumentation , Gait Analysis/methods , Gait Analysis/instrumentation , Electrodes , Shoes , Equipment Design
7.
Proc Natl Acad Sci U S A ; 121(22): e2404007121, 2024 May 28.
Article in English | MEDLINE | ID: mdl-38768347

ABSTRACT

Sensations of heat and touch produced by receptors in the skin are of essential importance for perceptions of the physical environment, with a particularly powerful role in interpersonal interactions. Advances in technologies for replicating these sensations in a programmable manner have the potential not only to enhance virtual/augmented reality environments but they also hold promise in medical applications for individuals with amputations or impaired sensory function. Engineering challenges are in achieving interfaces with precise spatial resolution, power-efficient operation, wide dynamic range, and fast temporal responses in both thermal and in physical modulation, with forms that can extend over large regions of the body. This paper introduces a wireless, skin-compatible interface for thermo-haptic modulation designed to address some of these challenges, with the ability to deliver programmable patterns of enhanced vibrational displacement and high-speed thermal stimulation. Experimental and computational investigations quantify the thermal and mechanical efficiency of a vertically stacked design layout in the thermo-haptic stimulators that also supports real-time, closed-loop control mechanisms. The platform is effective in conveying thermal and physical information through the skin, as demonstrated in the control of robotic prosthetics and in interactions with pressure/temperature-sensitive touch displays.


Subject(s)
Touch , Virtual Reality , Wireless Technology , Humans , Wireless Technology/instrumentation , Touch/physiology , Skin , Robotics/instrumentation , Robotics/methods
8.
J Physiol Sci ; 74(1): 30, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773373

ABSTRACT

Experiments measuring evoked potentials require flexible and rapid adjustment of stimulation and recording parameters. In this study, we have developed a recording system and an associated Android application that allow making such adjustments wirelessly. The system consists of 3 units: for stimulation, recording and control. Most of the modules in this system are custom made, although the stimulator and tablet are off-the-shelf products. When installed on the tablet, our Android application allows wireless communication with the control unit from a distance of 5 m. In testing, the recording unit had low internal noise and displayed signals faithfully. Upon receiving commands from the control unit, the stimulation unit produced precisely timed pulse outputs. Using this system, we were able to record evoked field potentials in the dentate gyrus of a rat; responses increased as expected with increasing stimulation pulse amplitude and duration.


Subject(s)
Evoked Potentials , Wireless Technology , Animals , Wireless Technology/instrumentation , Rats , Evoked Potentials/physiology , Male , Electric Stimulation/methods , Dentate Gyrus/physiology
9.
Transl Vis Sci Technol ; 13(5): 18, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38776108

ABSTRACT

Purpose: We aimed to design, develop, and evaluate an internet of things-enabled patch (IoT patch) for real-time remote monitoring of adherence (or patch wear time) during patch treatment in child participants in clinical trials. This study provides healthcare providers with a tool for objective, real-time, and remote assessment of adherence and for making required adjustments to treatment plans. Methods: The IoT patch had two temperature microsensors and a wireless chip. One sensor was placed closer to the skin than the other, resulting in a temperature difference depending on whether the patch was worn. When the patch was worn, it measured temperatures every 30 seconds and transmitted temperature data to a cloud server via a mobile application every 15 seconds. The patch was evaluated via 2 experiments with 30 healthy adults and 40 children with amblyopia. Results: Excellent monitoring accuracy was observed in both adults (mean delay of recorded time data, 0.4 minutes) and children (mean, 0.5 minutes). The difference between manually recorded and objectively recorded patch wear times showed good agreement in both groups. Experiment 1 showed accurate monitoring over a wide range of temperatures (from 0 to 30°C). Experiment 2 showed no significant differences in wearability (ease-of-use and comfort scores) between the IoT and conventional patches. Conclusions: The IoT patch offers an accurate, real-time, and remote system to monitor adherence to patch treatment. The patch is comfortable and easy to use. The utilization of an IoT patch may increase adherence to patch treatment based on accurate monitoring. Translational Relevance: Results show that the IoT patch can enable real-time adherence monitoring in clinical trials, improving treatment precision, and patient compliance to enhance outcomes.


Subject(s)
Internet of Things , Wireless Technology , Humans , Female , Male , Adult , Child , Wireless Technology/instrumentation , Patient Compliance , Equipment Design/methods , Child, Preschool , Young Adult , Wearable Electronic Devices , Remote Sensing Technology/instrumentation , Remote Sensing Technology/methods
10.
Article in English | MEDLINE | ID: mdl-38753470

ABSTRACT

This study presents a wireless wearable portable system designed for the automatic quantitative spatio-temporal analysis of continuous thoracic spine motion across various planes and degrees of freedom (DOF). This includes automatic motion segmentation, computation of the range of motion (ROM) for six distinct thoracic spine movements across three planes, tracking of motion completion cycles, and visualization of both primary and coupled thoracic spine motions. To validate the system, this study employed an Inter-days experimental setting to conduct experiments involving a total of 957 thoracic spine movements, with participation from two representatives of varying age and gender. The reliability of the proposed system was assessed using the Intraclass Correlation Coefficient (ICC) and Standard Error of Measurement (SEM). The experimental results demonstrated strong ICC values for various thoracic spine movements across different planes, ranging from 0.774 to 0.918, with an average of 0.85. The SEM values ranged from 0.64° to 4.03°, with an average of 1.93°. Additionally, we successfully conducted an assessment of thoracic spine mobility in a stroke rehabilitation patient using the system. This illustrates the feasibility of the system for actively analyzing thoracic spine mobility, offering an effective technological means for non-invasive research on thoracic spine activity during continuous movement states.


Subject(s)
Movement , Range of Motion, Articular , Thoracic Vertebrae , Wearable Electronic Devices , Humans , Thoracic Vertebrae/physiology , Male , Range of Motion, Articular/physiology , Female , Reproducibility of Results , Adult , Movement/physiology , Equipment Design , Algorithms , Wireless Technology/instrumentation , Stroke Rehabilitation/instrumentation , Biomechanical Phenomena , Young Adult , Middle Aged , Monitoring, Ambulatory/instrumentation
11.
Biosens Bioelectron ; 258: 116298, 2024 Aug 15.
Article in English | MEDLINE | ID: mdl-38701537

ABSTRACT

Wireless activation of the enteric nervous system (ENS) in freely moving animals with implantable optogenetic devices offers a unique and exciting opportunity to selectively control gastrointestinal (GI) transit in vivo, including the gut-brain axis. Programmed delivery of light to targeted locations in the GI-tract, however, poses many challenges not encountered within the central nervous system (CNS). We report here the development of a fully implantable, battery-free wireless device specifically designed for optogenetic control of the GI-tract, capable of generating sufficient light over large areas to robustly activate the ENS, potently inducing colonic motility ex vivo and increased propulsion in vivo. Use in in vivo studies reveals unique stimulation patterns that increase expulsion of colonic content, likely mediated in part by activation of an extrinsic brain-gut motor pathway, via pelvic nerves. This technology overcomes major limitations of conventional wireless optogenetic hardware designed for the CNS, providing targeted control of specific neurochemical classes of neurons in the ENS and brain-gut axis, for direct modulation of GI-transit and associated behaviours in freely moving animals.


Subject(s)
Enteric Nervous System , Optogenetics , Wireless Technology , Animals , Optogenetics/instrumentation , Enteric Nervous System/physiology , Mice , Wireless Technology/instrumentation , Brain-Gut Axis/physiology , Biosensing Techniques/instrumentation , Equipment Design , Brain/physiology , Mice, Inbred C57BL
12.
Nat Commun ; 15(1): 4035, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38740742

ABSTRACT

Rapid and accurate detection of respiratory virus aerosols is highlighted for virus surveillance and infection control. Here, we report a wireless immunoassay technology for fast (within 10 min), on-site (wireless and battery-free), and sensitive (limit of detection down to fg/L) detection of virus antigens in aerosols. The wireless immunoassay leverages the immuno-responsive hydrogel-modulated radio frequency resonant sensor to capture and amplify the recognition of virus antigen, and flexible readout network to transduce the immuno bindings into electrical signals. The wireless immunoassay achieves simultaneous detection of respiratory viruses such as severe acute respiratory syndrome coronavirus 2, influenza A H1N1 virus, and respiratory syncytial virus for community infection surveillance. Direct detection of unpretreated clinical samples further demonstrates high accuracy for diagnosis of respiratory virus infection. This work provides a sensitive and accurate immunoassay technology for on-site virus detection and disease diagnosis compatible with wearable integration.


Subject(s)
Hydrogels , Influenza A Virus, H1N1 Subtype , SARS-CoV-2 , Wireless Technology , Immunoassay/methods , Immunoassay/instrumentation , Humans , Hydrogels/chemistry , SARS-CoV-2/immunology , SARS-CoV-2/isolation & purification , Wireless Technology/instrumentation , Influenza A Virus, H1N1 Subtype/immunology , Influenza A Virus, H1N1 Subtype/isolation & purification , Aerosols , COVID-19/diagnosis , COVID-19/virology , COVID-19/immunology , Antigens, Viral/immunology , Antigens, Viral/analysis , Respiratory Syncytial Viruses/immunology , Respiratory Syncytial Viruses/isolation & purification , Limit of Detection
13.
Nat Commun ; 15(1): 4017, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38740759

ABSTRACT

Ultrasound-driven bioelectronics could offer a wireless scheme with sustainable power supply; however, current ultrasound implantable systems present critical challenges in biocompatibility and harvesting performance related to lead/lead-free piezoelectric materials and devices. Here, we report a lead-free dual-frequency ultrasound implants for wireless, biphasic deep brain stimulation, which integrates two developed lead-free sandwich porous 1-3-type piezoelectric composite elements with enhanced harvesting performance in a flexible printed circuit board. The implant is ultrasonically powered through a portable external dual-frequency transducer and generates programmable biphasic stimulus pulses in clinically relevant frequencies. Furthermore, we demonstrate ultrasound-driven implants for long-term biosafety therapy in deep brain stimulation through an epileptic rodent model. With biocompatibility and improved electrical performance, the lead-free materials and devices presented here could provide a promising platform for developing implantable ultrasonic electronics in the future.


Subject(s)
Deep Brain Stimulation , Wireless Technology , Deep Brain Stimulation/instrumentation , Deep Brain Stimulation/methods , Animals , Wireless Technology/instrumentation , Rats , Electrodes, Implanted , Epilepsy/therapy , Male , Prostheses and Implants , Rats, Sprague-Dawley , Transducers , Equipment Design , Ultrasonic Waves
14.
Sci Rep ; 14(1): 11526, 2024 May 21.
Article in English | MEDLINE | ID: mdl-38773136

ABSTRACT

This paper reports on the development of a flexible-wearable potentiometric sensor for real-time monitoring of sodium ion (Na+), potassium ion (K+), and pH in human sweat. Na0.44MnO2, polyaniline, and K2Co[Fe(CN)6] were used as sensing materials for Na+, H+ and K+ monitoring, respectively. The simultaneous potentiometric Na+, K+, and pH sensing were carried out by the developed sensor, which enables signal collection and transmission in real-time to the smartphone via a Wi-Fi access point. Then, the potentiometric responses were evaluated by a designed android application. Na+, K+, and pH sensors illustrated high sensitivity (59.7 ± 0.8 mV/decade for Na+, 57.8 ± 0.9 mV/decade for K+, and 54.7 ± 0.6 mV/pH for pH), excellent stability, and good batch-to-batch reproducibility. The results of on-body experiments demonstrated that the proposed platform is capable of real-time monitoring of the investigated ions.


Subject(s)
Potassium , Potentiometry , Sodium , Sweat , Wearable Electronic Devices , Humans , Hydrogen-Ion Concentration , Potentiometry/methods , Potentiometry/instrumentation , Sodium/analysis , Sweat/chemistry , Potassium/analysis , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Wireless Technology/instrumentation , Smartphone , Reproducibility of Results
15.
Acc Chem Res ; 57(9): 1275-1286, 2024 May 07.
Article in English | MEDLINE | ID: mdl-38608256

ABSTRACT

ConspectusEvolution of implantable neural interfaces is critical in addressing the challenges in understanding the fundamental working principles and therapeutic applications for central and peripheral nervous systems. Traditional approaches utilizing hermetically sealed, rigid electronics and detached electrodes face challenges in power supply, encapsulation, channel count, dispersed application location, and modality. Employing thin-film, wirelessly powered devices is promising to expand capabilities. Devices that forego bulky power supplies, favoring a configuration where electronics are integrated directly onto thin films, reduce displacement volumes for seamless, fully implantable interfaces with high energy availability and soft mechanics to conform to the neuronal target. We discuss 3 device architectures: (1) Highly miniaturized devices that merge electronics and neural interfaces into a single, injectable format; (2) Interfaces that consolidate power, computation, and neural connectivity on a thin sheet applied directly to the target area; (3) A spatially dislocated approach where power and computation are situated subdermally, connected via a thin interconnect to the neural interface.Each has advantages and constraints in terms of implantation invasiveness, power capturing efficiency, and directional sensitivity of power delivery. In powering these devices, near-field power delivery emerges as the most implemented technique. Key parameters are size and volume of primary and secondary antennas, which determine coupling efficiency and power delivery. Based on application requirements, ranging from small to large animal models, subjects require system level designs. Material strategies play a crucial role; monolithic designs, with materials like polyimide substrates, enable scalability with high performance. This contrasts with established hermetic encapsulation approaches that use a stainless steel or titanium box with passthroughs that result in large tissue displacements and prohibit intimate integration with target organ systems. Encapsulation, particularly with parylene, enables longevity and effectiveness; more research is needed to enable human lifetime operation. Implant-to-ambient device communication, focusing on strategies compatible with well-established standards and off-the-shelf electronics, is discussed with the goal of enabling seamless system integration, reliability, and scalability. The interface with the central nervous system is explored through various wireless, battery-free devices capable of both stimulation (electrical and optogenetic) and recording (photometric and electrochemical). These devices show advanced capabilities for chronic studies and insights into neural dynamics. In the peripheral nervous system, stimulation devices for applications, such as spinal and muscle stimulation, are discussed. The challenges lie in the mechanical and electrochemical durability. Examples that successfully navigate these challenges offer solutions for chronic studies in this domain. The potential of wireless, fully implantable nervous system interfaces using near field resonant power transfer is characterized by monolithically defined device architecture, providing a significant leap toward seamless access to the central and peripheral nervous systems. New avenues for research and therapeutic applications supporting a multimodal and multisite approach to neuromodulation with a high degree of connectivity and a holistic approach toward deciphering and supplementing the nervous system may enable recovery and treatment of injury and chronic disease.


Subject(s)
Wireless Technology , Wireless Technology/instrumentation , Humans , Electrodes, Implanted , Animals , Electric Power Supplies
16.
ACS Appl Mater Interfaces ; 16(17): 22522-22531, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38651323

ABSTRACT

Flexible bioelectronic devices that can perform real-time and accurate intraocular pressure (IOP) monitoring in both clinical and home settings hold significant implications for the diagnosis and treatment of glaucoma, yet they face challenges due to the open physiological environment of the ocular. Herein, we develop an intelligent wireless measuring contact lens (WMCL) incorporating a dual inductor-capacitor-resistor (LCR) resonant system to achieve temperature self-compensation for quantitative IOP monitoring in different application environments. The WMCL utilizes a compact circuitry design, which enables the integration of low-frequency and high-frequency resonators within a single layer of a sensing circuit without causing visual impairment. Mechanically guided microscale 3D encapsulation strategy combined with flexible circuit printing techniques achieves the surface-adaptive fabrication of the WMCL. The specific design of frequency separation imparts distinct temperature response characteristics to the dual resonators, and the linear combination of the dual resonators can eliminate the impact of temperature variations on measurement accuracy. The WMCL demonstrates outstanding sensitivity and linearity in monitoring the IOP of porcine eyes in vitro while maintaining satisfactory measurement accuracy even with internal temperature variations exceeding 10 °C. Overcoming the impact of temperature variations on IOP monitoring from the system level, the WMCL showcases immense potential as the next generation of all-weather IOP monitoring devices.


Subject(s)
Contact Lenses , Intraocular Pressure , Temperature , Wireless Technology , Intraocular Pressure/physiology , Wireless Technology/instrumentation , Animals , Swine , Equipment Design , Monitoring, Physiologic/instrumentation , Monitoring, Physiologic/methods , Humans
18.
Technol Health Care ; 32(3): 1341-1349, 2024.
Article in English | MEDLINE | ID: mdl-38108365

ABSTRACT

BACKGROUND: Implantable medical devices are being valued as one of the developments of wireless biomedical technology. OBJECTIVE: This paper presents a mid-field wireless power transmission (WPT) system, which is designed for implantable applications and operates at the 2.40-2.48 GHz band of Industrial, Scientific, and Medical (ISM). METHODS: A new compact transmitter structure is proposed, and a small 4-C planar ring antenna is designed as the receiving element. A measurement setup is fulfilled on porcine tissues to verify the power transmission system. RESULTS: The experimental results show that the operating bandwidth is 2.2-2.62 GHz and the transmission coefficient can reach -26.32 dB at a distance of 50 mm. The effects of tissue differences, placement depth, and different transmission distances were also measured. The displacement and deflection tolerances between the transmitter and the implant receiver also have good performance. In the safety standard of specific absorption rate, for the 1 W output power from the mid-field transmitter, the receiving power of the implantable antenna at the mid-field distance can reach 79.6 mW. CONCLUSION: With measurements of different implantation and transmission distance on pork, the mid-field power transmission efficiency is proven and shows the high performance of the system.


Subject(s)
Equipment Design , Prostheses and Implants , Wireless Technology , Wireless Technology/instrumentation , Animals , Swine , Electric Power Supplies
19.
Science ; 381(6662): 1105-1112, 2023 09 08.
Article in English | MEDLINE | ID: mdl-37676965

ABSTRACT

Early-stage organ transplant rejection can be difficult to detect. Percutaneous biopsies occur infrequently and are risky, and measuring biomarker levels in blood can lead to false-negative and -positive outcomes. We developed an implantable bioelectronic system capable of continuous, real-time, long-term monitoring of the local temperature and thermal conductivity of a kidney for detecting inflammatory processes associated with graft rejection, as demonstrated in rat models. The system detects ultradian rhythms, disruption of the circadian cycle, and/or a rise in kidney temperature. These provide warning signs of acute kidney transplant rejection that precede changes in blood serum creatinine/urea nitrogen by 2 to 3 weeks and approximately 3 days for cases of discontinued and absent administration of immunosuppressive therapy, respectively.


Subject(s)
Early Diagnosis , Graft Rejection , Kidney Diseases , Kidney Transplantation , Postoperative Complications , Wireless Technology , Animals , Rats , Kidney , Graft Rejection/diagnosis , Wireless Technology/instrumentation , Monitoring, Physiologic/instrumentation
20.
Nature ; 620(7973): 386-392, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37495692

ABSTRACT

Transient molecules in the gastrointestinal tract such as nitric oxide and hydrogen sulfide are key signals and mediators of inflammation. Owing to their highly reactive nature and extremely short lifetime in the body, these molecules are difficult to detect. Here we develop a miniaturized device that integrates genetically engineered probiotic biosensors with a custom-designed photodetector and readout chip to track these molecules in the gastrointestinal tract. Leveraging the molecular specificity of living sensors1, we genetically encoded bacteria to respond to inflammation-associated molecules by producing luminescence. Low-power electronic readout circuits2 integrated into the device convert the light emitted by the encapsulated bacteria to a wireless signal. We demonstrate in vivo biosensor monitoring in the gastrointestinal tract of small and large animal models and the integration of all components into a sub-1.4 cm3 form factor that is compatible with ingestion and capable of supporting wireless communication. With this device, diseases such as inflammatory bowel disease could be diagnosed earlier than is currently possible, and disease progression could be more accurately tracked. The wireless detection of short-lived, disease-associated molecules with our device could also support timely communication between patients and caregivers, as well as remote personalized care.


Subject(s)
Biomarkers , Biosensing Techniques , Hydrogen Sulfide , Inflammation , Nitric Oxide , Animals , Biomarkers/analysis , Biomarkers/metabolism , Biosensing Techniques/instrumentation , Biosensing Techniques/methods , Inflammatory Bowel Diseases/diagnosis , Inflammatory Bowel Diseases/metabolism , Models, Animal , Gastrointestinal Tract/metabolism , Gastrointestinal Tract/microbiology , Capsules/administration & dosage , Probiotics/metabolism , Bacteria/metabolism , Luminescence , Disease Progression , Inflammation/diagnosis , Inflammation/metabolism , Nitric Oxide/analysis , Nitric Oxide/metabolism , Hydrogen Sulfide/analysis , Hydrogen Sulfide/metabolism , Wireless Technology/instrumentation , Administration, Oral , Remote Sensing Technology/instrumentation , Remote Sensing Technology/methods , Time Factors , Humans , Body Size
SELECTION OF CITATIONS
SEARCH DETAIL
...