Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 591
Filter
1.
Ter Arkh ; 96(3): 246-252, 2024 Apr 16.
Article in Russian | MEDLINE | ID: mdl-38713039

ABSTRACT

AIM: To determine and compare the work of breathing to overcome elastic resistance (Ael) in patients with bronchial asthma (BA) and chronic obstructive pulmonary disease (COPD) with similar changes in the elastic properties of the parenchyma in the same settings of ventilation disorders (grade 1). MATERIALS AND METHODS: Differences in the manifestations of similar changes in the elastic properties of the lungs in patients with BA and COPD were evaluated. To identify differences, a comparative study was conducted on Аel overcome in BA patients with positive bronchodilator (with salbutamol) and bronchoconstrictor (with methacholine) tests, with reduced and preserved bronchial conductance (groups 1 and 2, respectively), and in COPD patients with negative bronchodilator and bronchoconstrictor tests (group 3). All study patients showed a grade 1 lung ventilation disorder (a decrease in the one-second forced expiratory volume by 15-35%). The results were compared with each other and with the control group (group 4, healthy non-smokers). All study patients were comparable by age and sex. The respiration mechanics was studied using simultaneous registration of spirogram and transpulmonary pressure, and the parameters of bronchial conductance and ventilation were determined using body plethysmopressography using the Jager software and hardware system. RESULTS AND CONCLUSION: In COPD patients, Ael was significantly increased (p>0.05), whereas in both BA groups, it was unchanged. Increased elastic work of breathing in patients with COPD may be associated with the involvement of certain types of contractile elements, which are preserved in patients with BA at the initial stages of the disease.


Subject(s)
Asthma , Pulmonary Disease, Chronic Obstructive , Humans , Pulmonary Disease, Chronic Obstructive/physiopathology , Male , Female , Asthma/physiopathology , Middle Aged , Work of Breathing/physiology , Lung/physiopathology , Adult , Elasticity , Respiratory Function Tests/methods , Bronchodilator Agents/pharmacology , Bronchodilator Agents/administration & dosage
2.
Med Sci Sports Exerc ; 56(6): 1168-1176, 2024 Jun 01.
Article in English | MEDLINE | ID: mdl-38350462

ABSTRACT

PURPOSE: We set out to understand how underband tightness or pressure of a sports bra relates to respiratory function and the mechanical work of breathing ( during exercise. Our secondary purpose was to quantify the effects of underband pressure on O 2 during submaximal running. METHODS: Nine highly trained female runners with normal pulmonary function completed maximal and submaximal running in three levels of underband restriction: loose, self-selected, and tight. RESULTS: During maximal exercise, we observed a significantly greater during the tight condition (350 ± 78 J·min -1 ) compared with the loose condition (301 ± 78 J·min -1 ; P < 0.05), and a 5% increase in minute ventilation ( ) during the tight condition compared with the loose condition ( P < 0.05). The pattern of breathing also differed between the two conditions; the greater maximal during the tight condition was achieved by a higher breathing frequency (57 ± 6 vs. 52 ± 7 breaths·min -1 ; P < 0.05), despite tidal volume being significantly lower in the tight condition compared with the loose condition (1.97 ± 0.20 vs. 2.05 ± 0.23 L; P < 0.05). During steady-state submaximal running, O 2 increased 1.3 ± 1.1% (range: -0.3 to 3.2%, P < 0.05) in the tight condition compared with the loose condition. CONCLUSIONS: Respiratory function may become compromised by the pressure exerted by the underband of a sports bra when women self-select their bra size. In the current study, loosening the underband pressure resulted in a decreased work of breathing, changed the ventilatory breathing pattern to deeper, less frequent breaths, and decreased submaximal oxygen uptake (improved running economy). Our findings suggest sports bra underbands can impair breathing mechanics during exercise and influence whole-body metabolic rate.


Subject(s)
Respiratory Mechanics , Running , Humans , Female , Running/physiology , Respiratory Mechanics/physiology , Adult , Work of Breathing/physiology , Young Adult , Sports Equipment , Oxygen Consumption/physiology , Tidal Volume/physiology
3.
Respir Physiol Neurobiol ; 313: 104070, 2023 07.
Article in English | MEDLINE | ID: mdl-37141930

ABSTRACT

This study compared work of breathing (WOB) and the pressure time product (PTP) to verify whether WOB and PTP decrease in the forward-leaning posture compared with erect sitting. Seven healthy adults (two females and five males) adopted three sitting postures: upright, and two forward-leaning postures of 15° and 30°. The WOB was obtained using the modified Campbell diagram, and PTP was calculated as the time integral of the area between esophageal and chest wall pressure. End-expiratory lung volume and transpulmonary pressure were significantly increased in the 15° and 30° forward-leaning postures compared with erect sitting (p â‰¦ 0.05). End-inspiratory lung volume was significantly increased in the 30° forward-leaning posture compared to erect sitting (p â‰¦ 0.05). PTP and inspiratory resistive WOB were significantly lower in the 15° and 30° forward-leaning postures compared to erect sitting (p â‰¦ 0.05). Forward leaning increases lung volume, which may dilate the airways, decrease resistant WOB, and reduce respiratory muscle activity.


Subject(s)
Respiration , Work of Breathing , Male , Adult , Female , Humans , Work of Breathing/physiology , Lung Volume Measurements , Posture/physiology , Upper Extremity
4.
Med Sci Sports Exerc ; 55(9): 1672-1682, 2023 09 01.
Article in English | MEDLINE | ID: mdl-37126027

ABSTRACT

INTRODUCTION: Measurement of the work of breathing (Wb) during exercise provides useful insights into the energetics and mechanics of the respiratory muscles across a wide range of minute ventilations. The methods and analytical procedures used to calculate the Wb during exercise have yet to be critically appraised in the literature. PURPOSE: The aim of this systematic review was to evaluate the quality of methods used to measure the Wb during exercise in the available literature. METHODS: We conducted an extensive search of three databases for studies that measured the Wb during exercise in adult humans. Data were extracted on participant characteristics, flow/volume and pressure devices, esophageal pressure (P oes ) catheters, and methods of Wb analysis. RESULTS: A total of 120 articles were included. Flow/volume sensors used were primarily pneumotachographs ( n = 85, 70.8%), whereas the most common pressure transducer was of the variable reluctance type ( n = 63, 52.5%). Esophageal pressure was frequently obtained via balloon-tipped catheters ( n = 114, 95.0%). Few studies mentioned calibration, frequency responses, and dynamic compensation of their measurement devices. The most popular method of measuring the Wb was pressure-volume integration ( n = 51, 42.5%), followed by the modified Campbell ( n = 28, 23.3%) and Dean & Visscher diagrams ( n = 26, 21.7%). Over one-third of studies did not report the methods used to process their pressure-volume data, and the majority (60.8%) of studies used the incorrect Wb units and/or failed to discuss the limitations of their Wb measurements. CONCLUSIONS: The findings of this systematic review highlight the need for the development of a standardized approach for measuring Wb, which is informative, practical, and accessible for future researchers.


Subject(s)
Respiration , Work of Breathing , Adult , Humans , Work of Breathing/physiology , Exercise/physiology , Respiratory Muscles/physiology
5.
Respir Res ; 23(1): 184, 2022 Jul 13.
Article in English | MEDLINE | ID: mdl-35831900

ABSTRACT

BACKGROUND: Ventilator liberation is one of the most challenging aspects in patients with respiratory failure. Most patients are weaned through a transition from full to partial respiratory support, whereas some advocate using a continuous spontaneous ventilation (CSV). However, there is little scientific evidence supporting the practice of pediatric ventilator liberation, including the timing of onset of and the approach to weaning mode. We sought to explore differences in patient effort between a pressure controlled continuous mode of ventilation (PC-CMV) [in this cohort PC assist/control (PC-A/C)] with a reduced ventilator rate and CSV, and to study changes in patient effort with decreasing PS. METHODS: In this prospective physiology cross-over study, we randomized children < 5 years to first PC-A/C with a 25% reduction in ventilator rate, or CSV (continuous positive airway pressure [CPAP] + PS). Patients were then crossed over to the other arm. Patient effort was measured by calculating inspiratory work of breathing (WOB) using the Campbell diagram (WOBCampbell), and by pressure-rate-product (PRP) and pressure-time-product (PTP). Respiratory inductance plethysmography (RIP) was used to calculate the phase angle. Measurements were obtained at baseline, during PC-A/C and CPAP + PS, and during decreasing set PS (maximum -6 cmH2O). RESULTS: Thirty-six subjects with a median age of 4.4 (IQR 1.5-11.9) months and median ventilation time of 4.9 (IQR 3.4-7.0) days were included. Nearly all patients (94.4%) were admitted with primary respiratory failure. WOBCampbell during baseline [0.67 (IQR 0.38-1.07) Joules/L] did not differ between CSV [0.49 (IQR 0.17-0.83) Joules/L] or PC-A/C [0.47 (IQR 0.17-1.15) Joules/L]. Neither PRP, PTP, ∆Pes nor phase angle was different between the two ventilator modes. Reducing pressure support resulted in a statistically significant increase in patient effort, albeit that these differences were clinically negligible. CONCLUSIONS: Patient effort during pediatric ventilation liberation was not increased when patients were in a CSV mode of ventilation compared to a ventilator mode with a ventilator back-up rate. Reducing the level of PS did not lead to clinically relevant increases in patient effort. These data may aid in a better approach to pediatric ventilation liberation. Trial registration clinicaltrials.gov NCT05254691. Registered 24 February 2022.


Subject(s)
Respiratory Insufficiency , Work of Breathing , Child , Continuous Positive Airway Pressure , Cross-Over Studies , Humans , Infant , Prospective Studies , Respiration, Artificial/methods , Respiratory Insufficiency/diagnosis , Respiratory Insufficiency/therapy , Ventilator Weaning , Work of Breathing/physiology
6.
Medwave ; 22(3): e8724, 2022 Apr 29.
Article in Spanish, English | MEDLINE | ID: mdl-35507808

ABSTRACT

Technological advances in mechanical ventilation have been essential to increasing the survival rate in intensive care units. Usually, patients needing mechanical ventilation use controlled ventilation to override the patients respiratory muscles and favor lung protection. Weaning from mechanical ventilation implies a transition towards spontaneous breathing, mainly using assisted mechanical ventilation. In this transition, the challenge for clinicians is to avoid under and over assistance and minimize excessive respiratory effort and iatrogenic diaphragmatic and lung damage. Esophageal balloon monitoring allows objective measurements of respiratory muscle activity in real time, but there are still limitations to its routine application in intensive care unit patients using mechanical ventilation. Like the esophageal balloon, respiratory muscle electromyography and diaphragmatic ultrasound are minimally invasive tools requiring specific training that monitor respiratory muscle activity. Particularly during the coronavirus disease pandemic, non invasive tools available on mechanical ventilators to monitor respiratory drive, inspiratory effort, and work of breathing have been extended to individualize mechanical ventilation based on patients needs. This review aims to identify the conceptual definitions of respiratory drive, inspiratory effort, and work of breathing and to identify non invasive maneuvers available on intensive care ventilators to measure these parameters. The literature highlights that although respiratory drive, inspiratory effort, and work of breathing are intuitive concepts, even distinguished authors disagree on their definitions.


Los avances tecnológicos de la ventilación mecánica han sido parte esencial del aumento de la sobrevida en las unidades de cuidados intensivos. Desde la conexión a la ventilación mecánica, comúnmente se utiliza ventilación controlada sin la consecuente participación de los músculos respiratorios del paciente, con el fin de favorecer la protección pulmonar. El retiro de la ventilación mecánica implica un periodo de transición hacia la respiración espontánea, utilizando principalmente ventilación mecánica asistida. En esta transición, el desafío de los clínicos es evitar la sub y sobre asistencia ventilatoria, minimizando el esfuerzo respiratorio excesivo, daño diafragmático y pulmonar inducidos por la ventilación mecánica. La monitorización con balón esofágico permite mediciones objetivas de la actividad muscular respiratoria en tiempo real, pero aún hay limitaciones para su aplicación rutinaria en pacientes ventilados mecánicamente en la unidad de cuidados intensivos. Al igual que el balón esofágico, la electromiografía de los músculos respiratorios y la ecografía diafragmática son herramientas que permiten monitorizar la actividad muscular de la respiración, siendo mínimamente invasivas y con requerimiento de entrenamiento específico. Particularmente, durante la actual pandemia de enfermedad por coronavirus se ha extendido el uso de herramientas no invasivas disponibles en los ventiladores mecánicos para monitorizar el impulso (drive), esfuerzo y trabajo respiratorio, para promover una ventilación mecánica ajustada a las necesidades del paciente. Consecuentemente, el objetivo de esta revisión es identificar las definiciones conceptuales de impulso, esfuerzo y trabajo respiratorio utilizadas en el contexto de la unidad de cuidados intensivos, e identificar las maniobras de medición no invasivas disponibles en los ventiladores de cuidados intensivos para monitorizar impulso, esfuerzo y trabajo respiratorio. La literatura destaca que, aunque los conceptos de impulso, esfuerzo y trabajo respiratorio se perciben intuitivos, no existe una definición clara. Asimismo, destacados autores los definen como conceptos diferentes.


Subject(s)
Pandemics , Work of Breathing , Critical Care , Humans , Respiration, Artificial , Ventilators, Mechanical , Work of Breathing/physiology
7.
Eur J Pediatr ; 181(6): 2453-2458, 2022 Jun.
Article in English | MEDLINE | ID: mdl-35304647

ABSTRACT

Congenital diaphragmatic hernia (CDH) results in varying degrees of pulmonary hypoplasia. Volume targeted ventilation (VTV) is a lung protective strategy but the optimal target tidal volume in CDH infants has not previously been studied. The aim of this study was to test the hypothesis that low targeted volumes would be better in CDH infants as determined by measuring the work of breathing (WOB) in CDH infants, at three different targeted tidal volumes. A randomised cross-over study was undertaken. Infants were eligible for inclusion in the study after surgical repair of their diaphragmatic defect. Targeted tidal volumes of 4, 5, and 6 ml/kg were each delivered in random order for 20-min periods with 20-min periods of baseline ventilation between. WOB was assessed and measured by using the pressure-time product of the diaphragm (PTPdi). Nine infants with a median gestational age at birth of 38 + 4 (range 36 + 4-40 + 6) weeks and median birth weight 3202 (range 2855-3800) g were studied. The PTPdi was higher at 4 ml/kg than at both 5, p = 0.008, and 6 ml/kg, p = 0.012. CONCLUSION: VTV of 4 ml/kg demonstrated an increased PTPdi compared to other VTV levels studied and should be avoided in post-surgical CDH infants. WHAT IS KNOWN: • Lung injury secondary to mechanical ventilation increases the mortality and morbidity of infants with CDH. • Volume targeted ventilation (VTV) reduces 'volutrauma' and ventilator-induced lung injury in other neonatal intensive care populations. WHAT IS NEW: • A randomised cross-over trial was carried out investigating the response to different VTV levels in infants with CDH. • Despite pulmonary hypoplasia being a common finding in CDH, a VTV of 5ml/kg significantly reduced the work of breathing in infants with CDH compared to a lower VTV level.


Subject(s)
Hernias, Diaphragmatic, Congenital , Cross-Over Studies , Hernias, Diaphragmatic, Congenital/surgery , Humans , Infant , Infant, Newborn , Respiration, Artificial/methods , Tidal Volume , Work of Breathing/physiology
8.
Crit Care Med ; 50(2): 192-203, 2022 02 01.
Article in English | MEDLINE | ID: mdl-35100192

ABSTRACT

OBJECTIVES: Lung- and diaphragm-protective ventilation is a novel concept that aims to limit the detrimental effects of mechanical ventilation on the diaphragm while remaining within limits of lung-protective ventilation. The premise is that low breathing effort under mechanical ventilation causes diaphragm atrophy, whereas excessive breathing effort induces diaphragm and lung injury. In a proof-of-concept study, we aimed to assess whether titration of inspiratory support based on diaphragm effort increases the time that patients have effort in a predefined "diaphragm-protective" range, without compromising lung-protective ventilation. DESIGN: Randomized clinical trial. SETTING: Mixed medical-surgical ICU in a tertiary academic hospital in the Netherlands. PATIENTS: Patients (n = 40) with respiratory failure ventilated in a partially-supported mode. INTERVENTIONS: In the intervention group, inspiratory support was titrated hourly to obtain transdiaphragmatic pressure swings in the predefined "diaphragm-protective" range (3-12 cm H2O). The control group received standard-of-care. MEASUREMENTS AND MAIN RESULTS: Transdiaphragmatic pressure, transpulmonary pressure, and tidal volume were monitored continuously for 24 hours in both groups. In the intervention group, more breaths were within "diaphragm-protective" range compared with the control group (median 81%; interquartile range [64-86%] vs 35% [16-60%], respectively; p < 0.001). Dynamic transpulmonary pressures (20.5 ± 7.1 vs 18.5 ± 7.0 cm H2O; p = 0.321) and tidal volumes (7.56 ± 1.47 vs 7.54 ± 1.22 mL/kg; p = 0.961) were not different in the intervention and control group, respectively. CONCLUSIONS: Titration of inspiratory support based on patient breathing effort greatly increased the time that patients had diaphragm effort in the predefined "diaphragm-protective" range without compromising tidal volumes and transpulmonary pressures. This study provides a strong rationale for further studies powered on patient-centered outcomes.


Subject(s)
Diaphragm/metabolism , Lung/metabolism , Respiration, Artificial/standards , Work of Breathing/physiology , Diaphragm/physiopathology , Female , Humans , Intensive Care Units/organization & administration , Intensive Care Units/statistics & numerical data , Lung/physiopathology , Male , Middle Aged , Netherlands/epidemiology , Respiration, Artificial/methods , Respiration, Artificial/statistics & numerical data , Respiratory Insufficiency/epidemiology , Respiratory Insufficiency/prevention & control , Respiratory Insufficiency/therapy , Work of Breathing/drug effects
9.
Crit Care ; 25(1): 327, 2021 09 08.
Article in English | MEDLINE | ID: mdl-34496927

ABSTRACT

A helmet, comprising a transparent hood and a soft collar, surrounding the patient's head can be used to deliver noninvasive ventilatory support, both as continuous positive airway pressure and noninvasive positive pressure ventilation (NPPV), the latter providing active support for inspiration. In this review, we summarize the technical aspects relevant to this device, particularly how to prevent CO2 rebreathing and improve patient-ventilator synchrony during NPPV. Clinical studies describe the application of helmets in cardiogenic pulmonary oedema, pneumonia, COVID-19, postextubation and immune suppression. A section is dedicated to paediatric use. In summary, helmet therapy can be used safely and effectively to provide NIV during hypoxemic respiratory failure, improving oxygenation and possibly leading to better patient-centred outcomes than other interfaces.


Subject(s)
Interactive Ventilatory Support/methods , Noninvasive Ventilation/methods , Work of Breathing/physiology , COVID-19 , Humans , Monitoring, Physiologic/methods , Noninvasive Ventilation/instrumentation , Respiratory Insufficiency/therapy
11.
Undersea Hyperb Med ; 48(2): 107-117, 2021.
Article in English | MEDLINE | ID: mdl-33975401

ABSTRACT

Introduction: Pre-dive altitude exposure may increase respiratory fatigue and subsequently augment exercise ventilation at depth. This study examined pre-dive altitude exposure and the efficacy of resistance respiratory muscle training (RMT) on respiratory fatigue while diving at altitude. Methods: Ten men (26±5 years; VO2peak: 39.8±3.3 mL• kg-1•min-1) performed three dives; one control (ground level) and two simulated altitude dives (3,658 m) to 17 msw, relative to ground level, before and after four weeks of resistance RMT. Subjects performed pulmonary function testing (e.g., inspiratory [PI] and expiratory [PE] pressure testing) pre- and post-RMT and during dive visits. During each dive, subjects exercised for 18 minutes at 55% VO2peak, and ventilation (VE), breathing frequency (ƒb,), tidal volume (VT) and rating of perceived exertion (RPE) were measured. Results: Pre-dive altitude exposure reduced PI before diving (p=0.03), but had no effect on exercise VE, ƒb, or VT at depth. At the end of the dive in the pre-RMT condition, RPE was lower (p=0.01) compared to control. RMT increased PI and PE (p<0.01). PE was reduced from baseline after diving at altitude (p<0.03) and this was abated after RMT. RMT did not improve VE or VT at depth, but decreased ƒb (p=0.01) and RPE (p=0.048) during the final minutes of exercise. Conclusion: Acute altitude exposure pre- and post-dive induces decrements in PI and PE before and after diving, but does not seem to influence ventilation at depth. RMT reduced ƒb and RPE during exercise at depth, and may be useful to reduce work of breathing and respiratory fatigue during dives at altitude.


Subject(s)
Altitude , Breathing Exercises/methods , Diving/physiology , Exercise/physiology , Muscle Fatigue/physiology , Work of Breathing/physiology , Adult , Analysis of Variance , Environmental Exposure , Exhalation/physiology , Heart Rate , Humans , Inhalation/physiology , Male , Oxygen/blood , Oxygen Consumption/physiology , Physical Exertion/physiology , Resistance Training/methods , Respiratory Function Tests , Tidal Volume/physiology , Time Factors
12.
Crit Care ; 25(1): 60, 2021 02 15.
Article in English | MEDLINE | ID: mdl-33588912

ABSTRACT

BACKGROUND: Reverse triggering (RT) is a dyssynchrony defined by a respiratory muscle contraction following a passive mechanical insufflation. It is potentially harmful for the lung and the diaphragm, but its detection is challenging. Magnitude of effort generated by RT is currently unknown. Our objective was to validate supervised methods for automatic detection of RT using only airway pressure (Paw) and flow. A secondary objective was to describe the magnitude of the efforts generated during RT. METHODS: We developed algorithms for detection of RT using Paw and flow waveforms. Experts having Paw, flow and esophageal pressure (Pes) assessed automatic detection accuracy by comparison against visual assessment. Muscular pressure (Pmus) was measured from Pes during RT, triggered breaths and ineffective efforts. RESULTS: Tracings from 20 hypoxemic patients were used (mean age 65 ± 12 years, 65% male, ICU survival 75%). RT was present in 24% of the breaths ranging from 0 (patients paralyzed or in pressure support ventilation) to 93.3%. Automatic detection accuracy was 95.5%: sensitivity 83.1%, specificity 99.4%, positive predictive value 97.6%, negative predictive value 95.0% and kappa index of 0.87. Pmus of RT ranged from 1.3 to 36.8 cmH20, with a median of 8.7 cmH20. RT with breath stacking had the highest levels of Pmus, and RTs with no breath stacking were of similar magnitude than pressure support breaths. CONCLUSION: An automated detection tool using airway pressure and flow can diagnose reverse triggering with excellent accuracy. RT generates a median Pmus of 9 cmH2O with important variability between and within patients. TRIAL REGISTRATION: BEARDS, NCT03447288.


Subject(s)
Respiration, Artificial/methods , Work of Breathing/physiology , Aged , Area Under Curve , Female , Humans , Male , Middle Aged , Positive-Pressure Respiration/methods , Positive-Pressure Respiration/statistics & numerical data , Pressure , ROC Curve , Respiration, Artificial/statistics & numerical data , Respiratory Mechanics/physiology , Weights and Measures/instrumentation
13.
Chest ; 160(1): 199-208, 2021 07.
Article in English | MEDLINE | ID: mdl-33549601

ABSTRACT

BACKGROUND: Lymphangioleiomyomatosis (LAM) is a rare lung disease found primarily in women of childbearing age, characterized by the formation of air-filled cysts, which may be associated with reductions in lung function. An experimental, regional ultra-high resolution CT scan identified an additional volume of cysts relative to standard chest CT imaging, which consisted primarily of ultra-small cysts. RESEARCH QUESTION: What is the impact of these ultra-small cysts on the pulmonary function of patients with LAM? STUDY DESIGN AND METHODS: A group of 103 patients with LAM received pulmonary function tests and a CT examination in the same visit. Cyst score, the percentage lung volume occupied by cysts, was measured by using commercial software approved by the US Food and Drug Administration. The association between cyst scores and pulmonary function tests of diffusing capacity of the lungs for carbon monoxide (Dlco) (% predicted), FEV1 (% predicted), and FEV1/FVC (% predicted) was assessed with statistical analysis adjusted for demographic variables. The distributions of average cyst size and ultra-small cyst fraction among the patients were evaluated. RESULTS: The additional cyst volume identified by the experimental, higher resolution scan consisted of cysts of 2.2 ± 0.8 mm diameter on average and are thus labeled the "ultra-small cyst fraction." It accounted for 27.9 ± 19.0% of the total cyst volume among the patients. The resulting adjusted, whole-lung cyst scores better explained the variance of Dlco (P < .001 adjusted for multiple comparisons) but not FEV1 and FEV1/FVC (P = 1.00). The ultra-small cyst fraction contributed to the reduction in Dlco (P < .001) but not to FEV1 and FEV1/FVC (P = .760 and .575, respectively). The ultra-small cyst fraction and average cyst size were correlated with cyst burden, FEV1, and FEV1/FVC but less with Dlco. INTERPRETATION: The ultra-small cysts primarily contributed to the reduction in Dlco, with minimal effects on FEV1 and FEV1/FVC. Patients with lower cyst burden and better FEV1 and FEV1/FVC tended to have smaller average cyst size and higher ultra-small cyst fraction. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov; No.: NCT00001465; URL: www.clinicaltrials.gov.


Subject(s)
Airway Obstruction/etiology , Artificial Organs , Lung Neoplasms/complications , Lymphangioleiomyomatosis/complications , Printing, Three-Dimensional , Tomography, X-Ray Computed/methods , Work of Breathing/physiology , Airway Obstruction/physiopathology , Cysts/physiopathology , Diffusion , Humans , Lung , Lung Neoplasms/diagnosis , Lung Neoplasms/physiopathology , Lymphangioleiomyomatosis/diagnosis , Lymphangioleiomyomatosis/physiopathology , Respiratory Function Tests
14.
Med Sci Sports Exerc ; 53(1): 192-199, 2021 01.
Article in English | MEDLINE | ID: mdl-32520874

ABSTRACT

INTRODUCTION: The Turbine™ is a nasal dilator marketed to athletes to increase airflow, which may serve to reduce dyspnea and improve exercise performance, presumably via reductions in the work of breathing (WOB). However, the unpublished data supporting these claims were collected in individuals at rest that were exclusively nasal breathing. These data are not indicative of how the device influences breathing during exercise at higher ventilations when a larger proportion of breathing is through the mouth. Accordingly, the purpose of this study was to empirically test the efficacy of the Turbine™ during exercise. We hypothesized that the Turbine™ would modestly reduce the WOB at rest and very low exercise intensities but would have no effect on the WOB at moderate to high exercise intensities. METHODS: We conducted a randomized crossover study in young, healthy individuals (7M:1F; age = 27 ± 5 yr) with normal lung function. Each participant performed two incremental cycle exercise tests to exhaustion with the Turbine™ device or under a sham control condition. For the sham control condition, participants were told they were breathing a low-density gas to reduce the WOB, but they were actually breathing room air. The WOB was determined through the integration of ensemble averaged esophageal pressure-volume loops. Standard cardiorespiratory measures were recorded using a commercially available metabolic cart. Dyspnea was assessed throughout exercise using the 0-10 Borg scale. RESULTS: Peak V˙O2 and work rate were not different between conditions (P = 0.70 and P = 0.35, respectively). In addition, there was no interaction or main effect of condition on dyspnea, ventilation, or WOB throughout the exercise (all P > 0.05). CONCLUSION: These findings suggest that the Turbine™ does not reduce the WOB and has no effect on dyspnea or exercise capacity.


Subject(s)
Athletic Performance/physiology , Bicycling/physiology , Nasal Cavity/physiology , Sports Equipment , Work of Breathing/physiology , Adult , Airway Resistance , Dyspnea/physiopathology , Female , Humans , Male , Muscle Fatigue/physiology , Perception/physiology , Respiratory Muscles/physiology
15.
Respir Physiol Neurobiol ; 285: 103591, 2021 03.
Article in English | MEDLINE | ID: mdl-33271306

ABSTRACT

The objective of this study was to examine the effects of obesity on the oxygen (O2) cost of breathing using the eucapnic voluntary hyperpnea (EVH) technique in 10- and 11-year-old children. Seventeen children (8 without and 9 with obesity) underwent EVH trials at two levels of ventilation for assessing the O2 cost of breathing (slope of oxygen uptake, V˙O2 vs. minute ventilation) and a dual energy x-ray absorptiometry scan. Resting and EVH V˙O2 was higher in children with obesity when compared with children without obesity (P = 0.0096). The O2 cost of breathing did not statistically differ between children without (2.09 ± 0.46 mL/L) and with obesity (2.08 ± 0.64 mL/L, P = 0.99), but the intercept was significantly greater in children with obesity. Chest mass explained 85 % of the variance in resting V˙O2 in children with obesity. Higher resting energy requirements, attributable to increased chest mass, can increase the absolute metabolic costs of exercise and hyperpnea in children with obesity.


Subject(s)
Child Development/physiology , Oxygen Consumption/physiology , Pediatric Obesity/physiopathology , Work of Breathing/physiology , Child , Female , Humans , Male
16.
Sci Rep ; 10(1): 20730, 2020 11 26.
Article in English | MEDLINE | ID: mdl-33244048

ABSTRACT

Pulmonary function testing (PFT) is an important component for evaluating the outcome of experimental rodent models of respiratory diseases. Respiratory inductance plethysmography (RIP) provides a noninvasive method of PFT requiring minimal cooperation. RIP measures work of breathing (WOB) indices including phase angle (Ф), percent rib cage (RC %), breaths per minute (BPM), and labored breathing index (LBI) on an iPad. The aim of this study was to evaluate the utility of a recently developed research instrument, pneuRIP, for evaluation of WOB indices in a developmental rat model. Sprague Dawley rats (2 months old) were commercially acquired and anaesthetised with isoflurane. The pneuRIP system uses two elastic bands: one band (RC) placed around the rib cage under the upper armpit and another band (AB) around the abdomen. The typical thoracoabdominal motion (TAM) plot showed the abdomen and rib cage motion in synchrony. The plots of phase angle and LBI as a function of data point number showed that values were within the range. The distribution for phase angle and LBI was within a narrow range. pneuRIP testing provided instantaneous PFT results. This study demonstrated the utility of RIP as a rapid, noninvasive approach for evaluating treatment interventions in the rodent model.


Subject(s)
Plethysmography/methods , Work of Breathing/physiology , Abdomen/physiology , Animals , Child , Humans , Infant , Isoflurane/administration & dosage , Lung/drug effects , Lung/physiology , Models, Animal , Movement/drug effects , Movement/physiology , Rats , Rats, Sprague-Dawley , Respiration/drug effects , Respiratory Function Tests/methods , Respiratory Mechanics/drug effects , Respiratory Mechanics/physiology , Work of Breathing/drug effects
18.
Crit Care ; 24(1): 494, 2020 08 10.
Article in English | MEDLINE | ID: mdl-32778136

ABSTRACT

Deterioration of lung function during the first week of COVID-19 has been observed when patients remain with insufficient respiratory support. Patient self-inflicted lung injury (P-SILI) is theorized as the responsible, but there is not robust experimental and clinical data to support it. Given the limited understanding of P-SILI, we describe the physiological basis of P-SILI and we show experimental data to comprehend the role of regional strain and heterogeneity in lung injury due to increased work of breathing.In addition, we discuss the current approach to respiratory support for COVID-19 under this point of view.


Subject(s)
Coronavirus Infections/physiopathology , Disease Progression , Lung Injury/physiopathology , Pneumonia, Viral/physiopathology , Work of Breathing/physiology , COVID-19 , Coronavirus Infections/therapy , Critical Care , Humans , Lung Injury/etiology , Pandemics , Pneumonia, Viral/therapy , Randomized Controlled Trials as Topic , Respiration, Artificial
19.
Arch Dis Child Fetal Neonatal Ed ; 105(6): 669-671, 2020 Nov.
Article in English | MEDLINE | ID: mdl-32669360

ABSTRACT

BACKGROUND: The COVID-19 pandemic has raised concern for healthcare workers getting infected via aerosol from non-invasive respiratory support of infants. Attaching filters that remove viral particles in air from the expiratory limb of continuous positive airway pressure (CPAP) devices should theoretically decrease the risk. However, adding filters to the expiratory limb could add to expiratory resistance and thereby increase the imposed work of breathing (WOB). OBJECTIVE: To evaluate the effects on imposed WOB when attaching filters to the expiratory limb of CPAP devices. METHODS: Two filters were tested on three CPAP systems at two levels of CPAP in a mechanical lung model. Main outcome was imposed WOB. RESULTS: There was a minor increase in imposed WOB when attaching the filters. The differences between the two filters were small. CONCLUSION: To minimise contaminated aerosol generation during CPAP treatment, filters can be attached to expiratory tubing with only a minimal increase in imposed WOB in a non-humidified environment. Care has to be taken to avoid filter obstruction and replace filters as recommended.


Subject(s)
Continuous Positive Airway Pressure/instrumentation , Coronavirus Infections/prevention & control , Filtration/instrumentation , Infection Control/instrumentation , Pandemics/prevention & control , Pneumonia, Viral/prevention & control , Betacoronavirus , COVID-19 , Exhalation/physiology , Humans , Infant, Newborn , Intensive Care Units, Neonatal , Models, Anatomic , SARS-CoV-2 , Work of Breathing/physiology
20.
Respir Physiol Neurobiol ; 280: 103474, 2020 09.
Article in English | MEDLINE | ID: mdl-32531441

ABSTRACT

AIM: To describe the response of breathing pattern and inspiratory effort upon changes in assist level and to assesss if changes in respiratory rate may indicate changes in respiratory muscle effort. METHODS: Prospective study of 82 patients ventilated on proportional assist ventilation (PAV+). At three levels of assist (20 %-50 %-80 %), patients' inspiratory effort and breathing pattern were evaluated using a validated prototype monitor. RESULTS: Independent of the assist level, a wide range of respiratory rates (16-35br/min) was observed when patients' effort was within the accepted range. Changing the assist level resulted in paired changes in inspiratory effort and rate of the same tendency (increase or decrease) in all but four patients. Increasing the level in assist resulted in a 31 % (8-44 %) decrease in inspiratory effort and a 10 % (0-18 %) decrease in respiratory rate. The change in respiratory rate upon the change in assist correlated modestly with the change in the effort (R = 0.5). CONCLUSION: Changing assist level results in changes in both respiratory rate and effort in the same direction, with change in effort being greater than that of respiratory rate. Yet, neither the magnitude of respiratory rate change nor the resulting absolute value may reliably predict the level of effort after a change in assist.


Subject(s)
Inhalation/physiology , Interactive Ventilatory Support/methods , Respiratory Rate/physiology , Work of Breathing/physiology , Aged , Aged, 80 and over , Airway Resistance , Critical Illness/therapy , Female , Humans , Lung Compliance , Male , Maximal Respiratory Pressures , Middle Aged , Tidal Volume
SELECTION OF CITATIONS
SEARCH DETAIL
...