Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 9 de 9
Filtrar
1.
J Endovasc Ther ; : 15266028231224257, 2024 Jan 09.
Artículo en Inglés | MEDLINE | ID: mdl-38193446

RESUMEN

OBJECTIVE: The upside-down configuration of a Gore Excluder contralateral leg endoprosthesis has been used to overcome diameter differences in the endovascular treatment of aortoiliac aneurysms. Our goal was not to describe the technique but to study the applicability and safety. MATERIAL AND METHODS: Patients were retrospectively enrolled. The indication and details of the procedure were at the discretion of the treating physicians. A case report form was completed including baseline characteristics, indication for treatment, procedural data, and outcomes during follow-up. RESULTS: A total of 31 subjects were enrolled with a range of indications, including 3 patients treated in the emergency setting (9.7%). In 64.5% (n=20), it was a primary intervention for a common iliac aneurysm (n=10), internal iliac aneurysm (n=4), or abdominal aortic aneurysm (n=6). In 11 subjects (35.5%), treatment was performed after previous aortoiliac interventions, including anastomotic iliac artery aneurysm (n=5), type III endoleak (n=3), and endograft thrombus (n=3). Median follow-up was 13 months (range=1-142 months). During follow-up, 2 patients required an upside-down contralateral leg-related secondary intervention, one for an occlusion and another for a type Ia endoleak. There was no type Ib or III endoleak, and no migration, kinking/stenosis, or conversion to open repair was observed. The aneurysm-related mortality was 3.3% (n=1). CONCLUSION: An upside-down contralateral leg is a valuable technique that can be used to achieve adequate aneurysm exclusion or resolve complications. It is associated with a limited number of complications. CLINICAL IMPACT: This article studies the use of an upside-down iliac endograft. We describe a wide range of indications in which this previously published technique has been applied. In elective and acute settings and as primary and revision intervention an upside-down iliac endograft was performed successfully. Furthermore, follow-up data is presented showing the effectiveness of the technique. Knowledge of this procedure is a valuable addition to the skillset of every interventionalist.

2.
Eur J Vasc Endovasc Surg ; 64(6): 611-619, 2022 12.
Artículo en Inglés | MEDLINE | ID: mdl-35987507

RESUMEN

OBJECTIVE: The aim of the Endurant for Challenging Anatomy: Global Experience (EAGLE) registry is to evaluate prospectively the technical and clinical success rate of a stentgraft used in patients with challenging neck anatomy outside the instructions for use (IFU) but within objective anatomical limits. METHODS: This was a prospective, international, multicentre, observational study. From 1 February 2012 to 1 September 2017, patients with an abdominal aortic aneurysm with a challenging infrarenal neck that were deemed suitable for endovascular aneurysm repair were included prospectively at 23 European centres. Patients were distributed by anatomy into three groups: short neck (SN; infrarenal neck 5 - 10 mm in combination with suprarenal angulation [α] ≤ 45° and infrarenal angulation [ß] ≤ 60°); medium neck (MN; infrarenal neck 10 - 15 mm with α ≤ 60° and ß 60° - 75° or α 45°- 60° and ß ≤ 75°; and long angulated neck (LN; infrarenal neck ≥ 15 mm with α ≤ 75° and ß 75°- 90° or α 60°- 75° and ß ≤ 90°. All computed tomography scans were reviewed by an independent core laboratory. Primary outcomes were technical and clinical success. Secondary endpoints were peri-operative major adverse events, all cause mortality, aneurysm related mortality, endoleaks, migration, and secondary intervention. RESULTS: One hundred and fifty patients (81.3% male) were included (SN = 55, MN = 16, LN = 79). The median follow up was 36 ± 12.6 months. In the overall cohort, the technical success rate was 93.3%. Estimated freedom from aneurysm related death was 97.3% at three years. Freedom from secondary interventions was 84.7% at three years. Estimated clinical success was 96.0%, 90.8%, and 83.2% at 30 days, one year, and three years, respectively. Estimated freedom from all cause mortality, late type IA endoleak, and migration at three years was 75.1%, 93.7%, and 99.3%, respectively. CONCLUSION: The early and midterm results of the EAGLE registry show that endovascular repair with the Endurant stentgraft in selected patients with challenging infrarenal neck anatomy yields results in line with large "real world" registries. Long term results are awaited for more definitive conclusions.

3.
J Endovasc Ther ; 26(2): 238-244, 2019 04.
Artículo en Inglés | MEDLINE | ID: mdl-30898067

RESUMEN

PURPOSE: To analyze the results of endovascular repair of common iliac artery (CIA) aneurysms without preemptive coil embolization of the internal iliac artery (IIA). MATERIALS AND METHODS: Between January 2010 and July 2016, 79 patients (mean age 74.3±8.4 years; 76 men) underwent endovascular repair extending into the external iliac artery owing to a CIA aneurysm. The procedure was performed for a ruptured aneurysm in 22 (28%) patients. Eighty-one IIAs were intentionally covered. The median CIA diameter was 37 mm (range 20-90). The primary outcomes were the occurrence of type II endoleaks and the incidence of buttock claudication. RESULTS: Five (6%) patients died within 30 days (4 with ruptured aneurysms and 1 elective case). Two type II endoleaks originating from a covered IIA were recorded; one required an endovascular intervention because of aneurysm growth. The other patient died of a rupture based on an additional type III endoleak. Mean follow-up was 37.6±26.3 months. Nineteen (26%) patients required a secondary intervention. Buttock claudication was reported in 21 (28%) of 74 patients and persisted after 1 year in 7. No severe ischemic complications as a result of IIA coverage were recorded, and no revascularization was required during follow-up. CONCLUSION: Treatment of CIA aneurysms by overstenting the IIA without preemptive coil embolization is safe and has a low risk of type II endoleak and aneurysm growth. Persisting buttock claudication is rare.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Embolización Terapéutica , Procedimientos Endovasculares , Aneurisma Ilíaco/cirugía , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Embolización Terapéutica/efectos adversos , Embolización Terapéutica/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Aneurisma Ilíaco/diagnóstico por imagen , Aneurisma Ilíaco/mortalidad , Masculino , Complicaciones Posoperatorias/etiología , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
4.
J Endovasc Ther ; 25(3): 366-375, 2018 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-29575993

RESUMEN

PURPOSE: To describe the added value of determining changes in position and apposition on computed tomography angiography (CTA) after endovascular aneurysm repair (EVAR) to detect early caudal displacement of the device and to prevent type Ia endoleak. METHODS: Four groups of elective EVAR patients were selected from a dataset purposely enriched with type Ia endoleak and migration (>10 mm) cases. The groups included cases of late type Ia endoleak (n=36), migration (n=9), a type II endoleak (n=16), and controls without post-EVAR complications (n=37). Apposition of the endograft fabric with the aortic neck, shortest distance between the fabric and the renal arteries, expansion of the main body (or dilatation of the aorta in the infrarenal sealing zone), and tilt of the endograft toward the aortic axis were determined on the first postoperative and the last available CTA scan without type Ia endoleak or migration. Differences in these endograft dimensions were compared between the first vs last scan and among the 4 groups. RESULTS: No significant differences in endograft configurations were observed among the groups on the first postoperative CTA scan. On the last CTA scan before a complication arose, the position of the fabric relative to the renal arteries, expansion of the main body, and apposition of the fabric with the aortic neck were significantly different between the type Ia endoleak (median follow-up 15 months) and migration groups (median follow-up 23 months) compared with the control group (median follow-up 19 months). Most endograft dimensions had changed significantly compared with the first postoperative CTA scan for all groups. Apposition had increased in the control group but had decreased significantly in the type Ia endoleak and migration groups. CONCLUSION: Progressive changes in dimensions of the endograft within the infrarenal neck could be detected on regular CTA scans before the complication became urgent in many patients.


Asunto(s)
Aorta Abdominal/cirugía , Aneurisma de la Aorta Abdominal/cirugía , Aortografía/métodos , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Angiografía por Tomografía Computarizada , Endofuga/diagnóstico por imagen , Procedimientos Endovasculares/instrumentación , Migración de Cuerpo Extraño/diagnóstico por imagen , Stents , Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Implantación de Prótesis Vascular/efectos adversos , Bases de Datos Factuales , Diagnóstico Precoz , Endofuga/etiología , Procedimientos Endovasculares/efectos adversos , Migración de Cuerpo Extraño/etiología , Humanos , Imagenología Tridimensional , Valor Predictivo de las Pruebas , Interpretación de Imagen Radiográfica Asistida por Computador , Estudios Retrospectivos , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento
5.
J Cardiovasc Surg (Torino) ; 59(2): 158-163, 2018 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-29327573

RESUMEN

Peripheral artery disease affects 202 million patients worldwide and may cause disabling intermittent claudication and critical limb ischemia. Next to life style changes, best medical treatment and supervised exercise therapy, it can be necessary to re-vascularize the limb. Treatment of femoropopliteal lesions poses a challenge and a surgical bypass remains recommended in the guidelines for longer and more complex lesions. Bypass surgery is associated with substantial morbidity and even mortality. Endovascular alternatives are quickly evolving from plain balloon angioplasty to drug-eluting stents, drug-coated balloons, polytetrafluoroethylene-covered stents and atherectomy. These developments might challenge the gold standard in the near future. This article focuses on which technique can be used for which femoropopliteal lesion, particularly complex lesions, and summarizes the most recent and important literature on this topic.


Asunto(s)
Angioplastia de Balón , Aterectomía , Endarterectomía , Arteria Femoral/cirugía , Claudicación Intermitente/terapia , Isquemia/terapia , Enfermedad Arterial Periférica/terapia , Arteria Poplítea/cirugía , Injerto Vascular , Angioplastia de Balón/efectos adversos , Angioplastia de Balón/instrumentación , Aterectomía/efectos adversos , Materiales Biocompatibles Revestidos , Stents Liberadores de Fármacos , Endarterectomía/efectos adversos , Arteria Femoral/fisiopatología , Humanos , Claudicación Intermitente/diagnóstico , Claudicación Intermitente/fisiopatología , Isquemia/diagnóstico , Isquemia/fisiopatología , Enfermedad Arterial Periférica/diagnóstico , Enfermedad Arterial Periférica/fisiopatología , Politetrafluoroetileno/química , Arteria Poplítea/fisiopatología , Resultado del Tratamiento , Dispositivos de Acceso Vascular , Injerto Vascular/efectos adversos , Grado de Desobstrucción Vascular
6.
J Vasc Surg ; 66(3): 735-742, 2017 09.
Artículo en Inglés | MEDLINE | ID: mdl-28366303

RESUMEN

OBJECTIVE: Stent graft evolution is often addressed as a cause for improved outcomes of endovascular aneurysm repair for patients with an abdominal aortic aneurysm. In this study, we directly compared the midterm result of Endurant stent graft with its predecessor, the Talent stent graft (both Medtronic, Santa Rosa, Calif). METHODS: Patient treated from January 2005 to December 2010 in a single tertiary center in The Netherlands with a Talent or Endurant stent graft were eligible for inclusion. Ruptured abdominal aortic aneurysms or patients with previous aortic surgery were excluded. The primary end point was the Kaplan-Meier estimated freedom from secondary interventions. Secondary end points were perioperative outcomes and indications for secondary interventions. RESULTS: In total, 221 patients were included (131 Endurant and 90 Talent). At baseline, the median aortic bifurcation was narrower for the Endurant (30 mm vs 39 mm; P < .001). Median follow-up was 64.1 ± 37.9 months and 59.2 ± 25.3 months for Talent and Endurant, respectively. The estimated freedom from secondary interventions at 30 days, 1 year, 5 years, and 7 years was 94.3%, 89.4%, 72.2%, and 64.1% for Talent and 96.8%, 89.3%, 75.2%, and 69.2% for Endurant (P = .528). The indication for secondary interventions does differ; more patients required an intervention for a proximal neck-related complication (type Ia endoleak or migration) in the Talent group (18.2% vs 4.8%; P = .001), whereas more interventions for iliac limb stenosis were seen in the Endurant group (0.0% vs 4.8%; P = .044). In a binomial regression analysis, suprarenal angulation, infrarenal neck length, and type of stent graft were independent predictors of neck-related complications. CONCLUSIONS: Evolution from the Talent stent graft into the Endurant has resulted in significant reduction of infrarenal neck-related complications; on the other hand, iliac interventions increased. The overall midterm secondary intervention rate was comparable.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Distribución de Chi-Cuadrado , Supervivencia sin Enfermedad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Modelos Logísticos , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Centros de Atención Terciaria , Factores de Tiempo , Resultado del Tratamiento
7.
J Endovasc Ther ; 23(4): 566-73, 2016 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-27179252

RESUMEN

PURPOSE: To evaluate the differences in technical outcomes and secondary interventions between elective endovascular aneurysm repair (el-EVAR) procedures and those for ruptured aneurysms (r-EVAR). METHODS: Of the 906 patients treated with primary EVAR from September 1998 until July 2012, 43 cases were excluded owing to the use of first-generation stent-grafts. Among the remaining 863 patients, 773 (89.6%) patients (mean age 72 years; 697 men) with asymptomatic or symptomatic abdominal aortic aneurysms (AAAs) were assigned to the el-EVAR group; 90 (10.4%) patients (mean age 73 years; 73 men) were assigned to the r-EVAR group based on blood outside the aortic wall on preoperative imaging. The primary study outcome was technical success; secondary endpoints, including freedom from secondary interventions and late survival, were examined with Kaplan-Meier analyses. RESULTS: At baseline, r-EVAR patients had larger aneurysms on average (p<0.001) compared to el-EVAR patients. Technical success was comparable (p=0.052), but there were more type Ia endoleaks at completion angiography in the r-EVAR group (p=0.038). As anticipated, more patients died in the first month in the r-EVAR group (18.9% vs 2.2% el-EVAR, p<0.001). At 5 years, there was an overall survival of 65.1% for the el-EVAR patients vs 48.1% in the r-EVAR group (p<0.001). The freedom from AAA-related mortality was 95.7% for el-EVAR and 71.0% for r-EVAR (p<0.001). Five-year freedom from type I/III endoleaks was significantly lower in the r-EVAR group (78.7% vs 90.0%, p=0.003). Five-year freedom from secondary intervention estimates were not significantly different (el-EVAR 84.2% vs r-EVAR 78.2%, p=0.064). CONCLUSION: Within our cohort of primary EVAR patients, r-EVAR cases showed comparable stent-graft-related technical outcome. Although there was a higher incidence of type Ia endoleaks on completion angiography in the r-EVAR group, the overall secondary intervention rate was comparable to el-EVAR.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Implantación de Prótesis Vascular , Procedimientos Endovasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico por imagen , Rotura de la Aorta/mortalidad , Aortografía , Prótesis Vascular , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/instrumentación , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Supervivencia sin Enfermedad , Procedimientos Quirúrgicos Electivos , Urgencias Médicas , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/instrumentación , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/mortalidad , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Estudios Retrospectivos , Factores de Riesgo , Stents , Factores de Tiempo , Resultado del Tratamiento
8.
J Vasc Surg ; 64(3): 557-62, 2016 09.
Artículo en Inglés | MEDLINE | ID: mdl-26994956

RESUMEN

OBJECTIVE: Lifelong yearly surveillance is advised after endovascular aneurysm repair (EVAR) for abdominal aortic aneurysms. This follow-up requires a substantial amount of health care resources. The aim of this paper was to assess the occurrence of stent graft-related complications and secondary interventions during a minimum 10-year follow-up after elective EVAR. METHODS: Patients who were treated in a high-volume endovascular center in The Netherlands with the Talent infrarenal stent graft (Medtronic Vascular, Santa Rosa, Calif) between June 1999 and February 2005 were included. Patients with previous aortic surgery or emergency interventions were excluded. Our primary outcome was clinical success up to 10 years. Secondary end points were technical success and survival. RESULTS: A total of 149 patients were included; 91.9% were male. The mean age was 70.2 ± 7.8 years. A stent graft was implanted in 98% of patients; technical success was achieved in 89.9%. Clinical success after 30 days, 1 year, 5 years, and 10 years was 81.1%, 74.3%, 70.3%, and 65.5%, respectively. In 30 patients (20.7%), a secondary intervention was required; 80.0% of first secondary interventions occurred within the first 5 years. Six late conversions were necessary because of stent graft infection (2), migration (2), or persisting endoleak (2). The 5- and 10-year overall survival rates were 55.2% and 38.6%, respectively. CONCLUSIONS: The risk of EVAR-related complication is highest in the first 5 years. Consequently, the main focus should be on that period; further follow-up must not be neglected, as complications occur up to 10 years after treatment.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Procedimientos Endovasculares/instrumentación , Stents , Anciano , Aneurisma de la Aorta Abdominal/diagnóstico por imagen , Aneurisma de la Aorta Abdominal/mortalidad , Implantación de Prótesis Vascular/efectos adversos , Implantación de Prótesis Vascular/mortalidad , Bases de Datos Factuales , Supervivencia sin Enfermedad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Hospitales de Alto Volumen , Humanos , Estimación de Kaplan-Meier , Masculino , Persona de Mediana Edad , Países Bajos , Complicaciones Posoperatorias/etiología , Complicaciones Posoperatorias/terapia , Diseño de Prótesis , Retratamiento , Estudios Retrospectivos , Factores de Riesgo , Tasa de Supervivencia , Factores de Tiempo , Resultado del Tratamiento
9.
J Vasc Surg ; 63(1): 49-54, 2016 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-26432284

RESUMEN

OBJECTIVE: A ruptured abdominal aortic aneurysm (RAAA) is associated with a high mortality rate. If cardiopulmonary resuscitation (CPR) is required before surgical repair, mortality rates are said to approach 100%. The aim of this multicenter, retrospective study was to study outcome in RAAA patients who required CPR before a surgical (endovascular or open) repair (CPR group). RAAA patients who did not need CPR served as controls (non-CPR group). METHODS: Over a 5-year time period, demographic and clinical characteristics and specifics of preoperative CPR if necessary were studied in all patients who were treated for a RAAA in three large, nonacademic hospitals. RESULTS: A total of 199 consecutive RAAA patients were available for analysis; 176 patients were surgically treated. Thirteen of these 176 patients (7.4%) needed CPR, and 163 (92.6%) did not. A 38.5% (5 of 13) survival rate was observed in the CPR group. Thirty-day mortality was almost three times greater in the CPR group compared with the non-CPR group (61.5% vs 22.7%; P = .005). Both CPR patients who received endovascular aortic repair survived. In contrast, survival in 11 CPR patients who underwent open RAAA repair was 27% (3 of 11; P = .128). A trend for higher Hardman index was found in patients who received CPR compared with patients who did not receive CPR (P = .052). The 30-day mortality in patients with a 0, 1, 2, or 3 Hardman index was 16.1%, 31.0%, 37.9%, and 33.3%, respectively (P = .093). CONCLUSIONS: An RAAA that requires preoperative CPR is not necessarily a lethal combination. Patient selection must be tailored before surgery is denied.


Asunto(s)
Aneurisma de la Aorta Abdominal/cirugía , Rotura de la Aorta/cirugía , Reanimación Cardiopulmonar , Procedimientos Endovasculares , Procedimientos Quirúrgicos Vasculares , Anciano , Anciano de 80 o más Años , Aneurisma de la Aorta Abdominal/diagnóstico , Aneurisma de la Aorta Abdominal/mortalidad , Rotura de la Aorta/diagnóstico , Rotura de la Aorta/mortalidad , Reanimación Cardiopulmonar/efectos adversos , Reanimación Cardiopulmonar/mortalidad , Procedimientos Endovasculares/efectos adversos , Procedimientos Endovasculares/mortalidad , Femenino , Humanos , Masculino , Persona de Mediana Edad , Países Bajos , Selección de Paciente , Cuidados Preoperatorios , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo , Factores de Tiempo , Resultado del Tratamiento , Procedimientos Quirúrgicos Vasculares/efectos adversos , Procedimientos Quirúrgicos Vasculares/mortalidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...