1.
Sensors (Basel) ; 24(5)2024 Feb 25.
Artículo en Inglés | MEDLINE | ID: mdl-38475024

RESUMEN

This study aims to illustrate the design, fabrication, and optimisation of an ultrasonic welding (UW) machine to join copper wires with non-woven PVC textiles as smart textiles. The study explicitly evaluates UW parameters' impact on heat generation, joint strength, and electrical properties, with a comprehensive understanding of the process dynamics and developing a predictive model applicable to smart textiles. The methodological approach involved designing and manufacturing an ultrasonic piezoelectric transducer using ABAQUS finite element analyses (FEA) software and constructing a UW machine for the current purpose. The full factorial design (FFD) approach was employed in experiments to systematically assess the influence of welding time, welding pressure, and copper wire diameter on the produced joints. Experimental data were meticulously collected, and a backpropagation neural network (BPNN) model was constructed based on the analysis of these results. The results of the experimental investigation provided valuable insights into the UW process, elucidating the intricate relationship between welding parameters and heat generation, joint strength, and post-welding electrical properties of the copper wires. This dataset served as the basis for developing a neural network model, showcasing a high level of accuracy in predicting welding outcomes compared to the FFD model. The neural network model provides a valuable tool for controlling and optimising the UW process in the realm of smart textile production.

2.
Bioengineering (Basel) ; 11(2)2024 Feb 01.
Artículo en Inglés | MEDLINE | ID: mdl-38391634

RESUMEN

PURPOSE: To investigate corneal densitometry artefacts found in Pentacam Scheimpflug scans and their potential effect on assessing keratoconic (KC) corneas compared to normal (N) corneas. METHODS: The current study utilises Pentacam data of 458 N eyes, aged 35.6 ± 15.8 (range 10-87), referred to as the "N group", and 314 KC eyes, aged 31.6 ± 10.8 (range 10-72), referred to as the "KC group", where densitometry data were extracted and analysed via a custom-built MATLAB code. Radial summations of the densitometry were calculated at diameters ranging from 0.5 mm to 5.0 mm. The minimum normalised radial summation of densitometry (NRSD) value and angle were determined at each diameter and then linked. KC cone locations and areas of pathology were determined, and a comparison between N and KC groups was carried out both within the averaged area of pathology and over the corneal surface. RESULTS: Joining minimum NRSD trajectory points marked a clear distortion line pointing to the nasal-superior direction at 65° from the nasal meridian. The findings were found to be independent of eye laterality or ocular condition. Consistency was detected in the right and left eyes among both the N and KC groups. The location of the KC cone centre and the area of pathology were determined, and the densitometry output was compared both within the area of pathology and over the whole cornea. When the average densitometry was compared between N and KC eyes within the KC area of pathology, the N group recorded a 16.37 ± 3.15 normalised grey-scale unit (NGSU), and the KC group recorded 17.74 ± 3.4 NGSU (p = 0.0001). However, when the whole cornea was considered, the N group recorded 16.71 ± 5.5 NGSU, and the KC group recorded 15.72 ± 3.98 NGSU (p = 0.0467). A weak correlation was found between the Bad D index and NGSU when the whole measured cornea was considered (R = -0.01); however, a better correlation was recorded within the KC area of pathology (R = 0.21). CONCLUSIONS: Nasal-superior artefacts are observed in the densitometry Pentacam maps, and analysis shows no significant differences in their appearance between N or KC corneas. When analysing KC corneas, it was found that the cone positions are mostly on the temporal-inferior side of the cornea, opposite to the densitometry artefact NRSD trajectory. The analysis suggests that the corneal densitometry artefacts do not interfere with the KC area of pathology as it reaches its extreme in the opposite direction; therefore, weighting the densitometry map to increase the contribution of the inferior-temporal cornea and decreasing that of the superior-nasal area would improve the classification or identification of KC if densitometry is to be used as a KC metric.

3.
Bioengineering (Basel) ; 11(2)2024 Feb 09.
Artículo en Inglés | MEDLINE | ID: mdl-38391654

RESUMEN

PURPOSE: To improve the effectivity of patient-specific finite element analysis (FEA) to predict refractive power change (RPC) in rigid Ortho-K contact lens fitting. Novel eyelid boundary detection is introduced to the FEA model to better model the effects of the lid on lens performance, and stress and strain outcomes are investigated to identify the most effective FEA components to use in modelling. METHODS: The current study utilises fully anonymised records of 249 eyes, 132 right eyes, and 117 left eyes from subjects aged 14.1 ± 4.0 years on average (range 9 to 38 years), which were selected for secondary analysis processing. A set of custom-built MATLAB codes was built to automate the process from reading Medmont E300 height and distance files to processing and displaying FEA stress and strain outcomes. Measurements from before and after contact lens wear were handled to obtain the corneal surface change in shape and power. Tangential refractive power maps were constructed from which changes in refractive power pre- and post-Ortho-K wear were determined as the refractive power change (RPC). A total of 249 patient-specific FEA with innovative eyelid boundary detection and 3D construction analyses were automatically built and run for every anterior eye and lens combination while the lens was located in its clinically detected position. Maps of four stress components: contact pressure, Mises stress, pressure, and maximum principal stress were created in addition to maximum principal logarithmic strain maps. Stress and strain components were compared to the clinical RPC maps using the two-dimensional (2D) normalised cross-correlation and structural similarity (SSIM) index measure. RESULTS: On the one hand, the maximum principal logarithmic strain recorded the highest moderate 2D cross-correlation area of 8.6 ± 10.3%, and contact pressure recorded the lowest area of 6.6 ± 9%. Mises stress recorded the second highest moderate 2D cross-correlation area with 8.3 ± 10.4%. On the other hand, when the SSIM index was used to compare the areas that were most similar to the clinical RPC, maximum principal stress was the most similar, with an average strong similarity percentage area of 26.5 ± 3.3%, and contact pressure was the least strong similarity area of 10.3 ± 7.3%. Regarding the moderate similarity areas, all components were recorded at around 34.4% similarity area except the contact pressure, which was down to 32.7 ± 5.8%. CONCLUSIONS: FEA is an increasingly effective tool in being able to predict the refractive outcome of Ortho-K treatment. Its accuracy depends on identifying which clinical and modelling metrics contribute to the most accurate prediction of RPC with minimal ocular complications. In terms of clinical metrics, age, Intra-ocular pressure (IOP), central corneal thickness (CCT), surface topography, lens decentration and the 3D eyelid effect are all important for effective modelling. In terms of FEA components, maximum principal stress was found to be the best FEA barometer that can be used to predict the performance of Ortho-K lenses. In contrast, contact pressure provided the worst stress performance. In terms of strain, the maximum principal logarithmic strain was an effective strain barometer.

4.
Exp Clin Transplant ; 22(Suppl 1): 348-353, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38385425

RESUMEN

Paradoxical embolism occurs when a thrombus crosses an intracardiac defect into the systemic circulation. Here, we present the case of a 35-yearold male kidney transplant recipient with a cerebral paradoxical embolism associated with a spontaneous venous thromboembolism. This patient had recurrent deep venous thrombosis and showering emboli to the lung and paradoxically to the brain through patent foramen ovale, and we treated him successfully. The role of bubble echocardiography was essential in diagnosis to avoid contrast-induced nephropathy. This is the first successfully managed case of a kidney transplant recipient with recurrent idiopathic deep vein thrombosis, pulmonary embolism, and cerebral paradoxical embolism. Bubble echocardiography was an excellent alternative to contrast angiography to avoid nephrotoxicity. Vitamin K antagonists are superior to direct oral anticoagulants, especially among nonadherent/noncompliant patients.


Asunto(s)
Embolia Paradójica , Foramen Oval Permeable , Trasplante de Riñón , Embolia Pulmonar , Trombosis de la Vena , Humanos , Masculino , Adulto , Embolia Paradójica/diagnóstico por imagen , Embolia Paradójica/etiología , Embolia Paradójica/cirugía , Trasplante de Riñón/efectos adversos , Embolia Pulmonar/diagnóstico por imagen , Embolia Pulmonar/tratamiento farmacológico , Embolia Pulmonar/etiología , Trombosis de la Vena/diagnóstico por imagen , Trombosis de la Vena/tratamiento farmacológico , Trombosis de la Vena/etiología , Foramen Oval Permeable/complicaciones , Anticoagulantes/uso terapéutico
5.
J Appl Genet ; 64(3): 569-590, 2023 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-37407883

RESUMEN

Among ten metal-tolerant fungal isolates obtained from the microbiomes of detergent industry effluent, Mucor sp. NRCC6 showed the highest tolerance and an adaptive behavior toward the heavy metals Ni2+, Pb2+, Mn2+, and Zn2+. It gave the highest growth rates 0.790 ± 0.59, 0.832 ± 0.32, 0.774 ± 0.40, and 0.741 ± 1.06 mm/h along with the lowest growth inhibition 9.19, 4.37, 11.04, and 14.83% in the presence of Pb2+, Zn2+, Ni2+, and Mn2+, respectively, at a concentration of 5.0 g/L. Then, Mucor sp. NRCC6 was selected as a biotrap for the removal of these heavy metals. The optimized operating conditions were detected to be pH 6.0 for Pb2+, Zn2+, and Mn2+ and pH 5.5 for Ni2+ at 30 °C; agitation speed 150 rpm; contact time 30 min for Mn2+ and Ni2+, 30-60 min for Pb2+, and 90-180 min for Zn2+; NRCC6 biomass dosage 5.0 g/L for Ni2+ and Pb2+ and 10.0 g/L for Mn2+ and Zn2+; and initial concentration 12 mg/L of each ion in the multimetal aqueous solutions. Under these optimized conditions, the adsorption capacity for Pb2+, Ni2+, Mn2+, and Zn2+ reached 98.75, 59.25, 58.33, and 50.83%. The Langmuir isotherm was the best for describing the adsorption of Zn2+ (0.970) and Mn2+ (0.977). The Freundlich isotherm significantly giving a good fit to the adsorption of Pb2+ (0.998) while the adsorption of Ni2+ onto NRCC6 biomass can follow DKR (0.998). Furthermore, the current study revealed that Mucor sp. NRCC6 fungus is a new efficient and eco-friendly method that revealed a maximum removal of 100% for Pb2+ and Zn2+ as well as 97.39, 88.70, 78.95, 74.0, 70.22, 68.57, and 60.0% for Ni2+, Mn2+, Cd2+, Cu2+, Fe3+, As2+, and Cr6+ from the industrial wastewater, respectively.


Asunto(s)
Metales Pesados , Mucor , Detergentes , Biodegradación Ambiental , Biomasa , Plomo , Metales Pesados/análisis , Agua
6.
Front Bioeng Biotechnol ; 11: 1146828, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37492801

RESUMEN

To estimate the material stiffness of the orbital soft tissue in human orbits using an inverse numerical analysis approach, which could be used in future studies to understand the behaviour under dynamic, non-contact tonometry or simulate various ophthalmological conditions. Clinical data were obtained for the left eye of 185 Chinese participants subjected to a complete ophthalmic examination, including tests by the Corvis ST and Pentacam. 185 numerical models of the eye globes were built with idealised geometry of the sclera while considering the corneal tomography measured by the Pentacam. The models were extended to include representations of the orbital soft tissue (OST), which were given idealised geometry. The movement of the whole eye in response to an air-puff directed at the central cornea was examined and used in an inverse analysis process to estimate the biomechanical stiffness parameters of the OST. The results indicated a weak correlation of E t with the progression of age, regardless of the stress at which E t was calculated. However, there was evidence of significant differences in E t between some of the age groups. There was statistical evidence of significant differences between E t in the age range 20< years < 43 relative to E t in OST with age ranges 43< years < 63 (p = 0.022) and 63< years < 91 (p = 0.011). In contrast, E t in OST with age ranges 43< years < 63 and 63< years < 91 were not significantly different (p = 0.863). The optimised mechanical properties of the OST were found to be almost four times stiffer than properties of fatty tissue of previous experimental work. This study consolidated previous findings of the role of extraocular muscles on the ocular suppor system. In addition, the rotation of the globe during corvis loading is suggested to be of posterior components of the globe and shall be further investigated.

7.
Biometals ; 36(6): 1307-1329, 2023 12.
Artículo en Inglés | MEDLINE | ID: mdl-37428423

RESUMEN

The present work investigated the utilization of dead biomass of the highly multi-heavy metals tolerant indigenous fungal strain NRCA8 isolated from the mycobiome of fertilizer industry effluents that containing multiple heavy metal ions at high levels to remove Pb2+, Ni2+, Zn2+, and Mn2+ as multiple solutes from multi-metals aqueous solutions for the first time. Based on morphotype, lipotype and genotype characteristics, NRCA8 was identified as Cladosporium sp. NRCA8. The optimal conditions for the bioremoval procedure in the batch system were pH 5.5 for maximum removal (91.30%, 43.25%, and 41.50%) of Pb2+, Zn2+ and Mn2+ but pH 6.0 supported the maximum bioremoval and uptake of Ni2+ (51.60% and 2.42 mg/g) by NRCA8 dead biomass from the multi-metals aqueous solution, respectively. The 30 min run time supported the highest removal efficiency and uptake capacity of all heavy metals under study. Moreover, the equilibrium between the sorbent NRCA8 fungal biomass and sorbates Ni2+, Pb2+ and Zn2+ was attained after increasing the dead biomass dose to 5.0 g/L. Dead NRCA8 biomass was described by scanning electron microscopy, energy-dispersive X-ray spectroscopy and Fourier transform infrared spectrometer before and after biosorption of Pb2+, Ni2+, Zn2+ and Mn2+ under multiple metals system. The Langmuir, Freundlich and Dubinin-Kaganer-Radushkevich isotherms were applied to characterize the adsorption equilibrium between Pb2+, Ni2+, Mn2+ and Zn2+ and the adsorbent NRCA8. By comparing the obtained coefficient of regression (R2) by Freundlich (0.997, 0.723, 0.999, and 0.917), Langmiur (0.974, 0.999, 0.974, and 0.911) and Dubinin-Radushkevich (0.9995, 0.756, 0.9996 and 0.900) isotherms values for Pb2+, Zn2+, Ni2+ and Mn2+ adsorption, respectively, it was found that the isotherms are proper in their own merits in characterization the possible of NRCA8 for removal of Pb2+, Zn2+, Ni2+ and Mn2+. DKR isotherm is the best for Pb2+ and Ni2+ (0.9995 and 0.9996) while Langmiur isotherm giving a good fit to the Zn2+ sorption (0.9990) as well as Freundlich isotherm giving a good fit to the Mn2+ sorption (0.9170). The efficiencies of Cladosporium sp. NRCA8 dead biomass for bioremoval of heavy metals from real wastewater under the optimized conditions were Pb2+, Ag+, Mn2+, Zn2+ and Al3+ ˃ Ni2+ ˃ Cr6+ ˃ Co2+ ˃ Fe3+ ˃ Cu2+ ˃ Cd2+. Dead NRCA8 biomass showed efficient ability to adsorb and reduce harmful components in the industrial effluents to a level acceptable for discharge into the environment.


Asunto(s)
Metales Pesados , Contaminantes Químicos del Agua , Fertilizantes , Biomasa , Plomo , Metales Pesados/química , Agua/química , Adsorción , Concentración de Iones de Hidrógeno , Cinética
8.
Heliyon ; 9(4): e13944, 2023 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-37101628

RESUMEN

Purpose: The study presents an averaged anterior eye geometry model combined with a localised material model that is straightforward, appropriate and amenable for implementation in finite element (FE) modelling. Methods: Both right and left eye profile data of 118 subjects (63 females and 55 males) aged 22-67 years (38.5 ± 7.6) were used to build an averaged geometry model. Parametric representation of the averaged geometry model was achieved through two polynomials dividing the eye into three smoothly connected volumes. This study utilised the collagen microstructure x-ray data of 6 ex-vivo healthy human eyes, 3 right eyes and 3 left eyes in pairs from 3 donors, 1 male and 2 females aged between 60 and 80 years, to build a localised element-specific material model for the eye. Results: Fitting the cornea and the posterior sclera sections to a 5th-order Zernike polynomial resulted in 21 coefficients. The averaged anterior eye geometry model recorded a limbus tangent angle of 37° at a radius of 6.6 mm from the corneal apex. In terms of material models, the difference between the stresses generated in the inflation simulation up to 15 mmHg in the ring-segmented material model and localised element-specific material model were significantly different (p < 0.001) with the ring-segmented material model recording average Von-Mises stress 0.0168 ± 0.0046 MPa and the localised element-specific material model recording average Von-Mises stress 0.0144 ± 0.0025 MPa. Conclusions: The study illustrates an averaged geometry model of the anterior human eye that is easy to generate through two parametric equations. This model is combined with a localised material model that can be used either parametrically through a Zernike fitted polynomial or non-parametrically as a function of the azimuth angle and the elevation angle of the eye globe. Both averaged geometry and localised material models were built in a way that makes them easy to implement in FE analysis without additional computation cost compared to the limbal discontinuity so-called idealised eye geometry model or ring-segmented material model.

9.
Curr Eye Res ; 48(4): 382-391, 2023 04.
Artículo en Inglés | MEDLINE | ID: mdl-36581595

RESUMEN

PURPOSE: To improve the stability of the Corvis ST biomechanically-corrected intraocular pressure measurements (bIOP) after refractive surgery and its independence of corneal biomechanics. METHODS: A parametric study was carried out using numerical models simulating the behavior of the eye globe under the effects of IOP and Corvis ST external air pressure and used to develop a new algorithm for bIOP; bIOP(v2). It was tested on 528 healthy participants to evaluate correlations with CCT and age. Its ability to compensate for the geometrical changes was tested in 60 LASIK and 80 SMILE patients with six months follow up. The uncorrected Corvis ST IOP (CVS-IOP) and the two versions of biomechanically corrected IOP; bIOP(v1) and bIOP(v2), were compared. RESULTS: In the healthy dataset, bIOP(v2) had weak and non-significant correlation with both CCT (R = -0.048, p = .266) and age (R = 0.085, p = .052). For bIOP(v1), the correlation was non-significant with CCT (R = -0.064, p = .139) but significant with age (R = -0.124, p < .05). In both LASIK and SMILE groups, the median change in bIOP(v2) following surgery was below 1 mmHg at follow-up stages and the interquartile range was smaller than both bIOP(v1) and CVS-IOP. CONCLUSION: The bIOP(v2) algorithm performs better than bIOP(v1) and CVS-IOP in terms of correlation with CCT and age. The bIOP(v2) also demonstrated the smallest variation after LASIK and SMILE refractive surgeries indicating improved ability to compensate for geometrical changes.


Asunto(s)
Glaucoma de Ángulo Abierto , Queratomileusis por Láser In Situ , Humanos , Presión Intraocular , Tonometría Ocular , Córnea , Fenómenos Biomecánicos
10.
Heliyon ; 8(11): e11699, 2022 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-36468117

RESUMEN

Purpose: To investigate the relationship between Ortho-K contact lens design parameters and refractive power change of the eye through a parametric mathematical representation. Methods: The current study utilises fully anonymized records of 249 eyes, 132 right eyes, and 117 left eyes from subjects aged 14.1 ± 4.0 years on average (range 9-38 years) which were selected for secondary analysis processing. The data were split into 3 groups (G1 up to 35 days wear, from 10 to 35 days, G2 up to 99 days wear, more than 35-99 days & G3 more than 100 days wear) according to the length of time, in days, that the lenses were worn. Corneal shape was measured before and after contact lens wear using the Medmont E300 topographer, from which height and distance files were read by a custom-built MATLAB code to construct the corneal anterior surface independently. Changes in refractive power pre and post-Ortho-K wear were determined using constructed tangential refractive power maps from which both centrally flattened and annular steepened zones were automatically bounded, hence used to determine the refractive power change. Results: On average, flat Sim-K and steep Sim-K were reduced after Ortho-K lens wear by 1.6 ± 1.3 D and 1.3 ± 1.4 D respectively. The radius of the base curve was correlated with the mean central flattened zone power change strongly in G1 (R = 0.7, p < 0.001) and moderately in G2 (R = 0.4) and G3 (R = 0.4, p < 0.001). Hence, a strong correlation with the base curve was recorded in group G1 and moderate in G2 and G3. The reverse curve was very strongly correlated to the mean central flattened zone power change in G1 (R = 0.8, p < 0.001) and strongly correlated with G2 (R = 0.6, p < 0.001) and G3 (R = 0.7, p < 0.001). The reverse curve was also strongly correlated with the mean annular steepened zone power change among all groups G1, G2, and G3 (R = 0.7, R = 0.6 and R = 0.6) respectively (p < 0.001). Conclusions: Although the central corneal refractive power change was strongly correlated to the Ortho-K lens base curve, it characterized only 50% of the target power change. However, the annular steepened zone refractive power change appears to be a clearer predictor of target power change, as there appears to be a one-to-one inverse relationship with the target refractive power correction. Differences between these results and the literature may be a result of the topography software smoothing effect.

11.
BMC Oral Health ; 22(1): 582, 2022 12 09.
Artículo en Inglés | MEDLINE | ID: mdl-36494727

RESUMEN

BACKGROUND: This study aimed to compare the maxillary sinus dimensions and surface area in accordance with skeletal malocclusion, gender and ethnicity factors in a sample of Chinese and Yemeni patients. METHODS: This cross-sectional study analysed 180 maxillary sinuses using 180 lateral cephalometric radiographs. The patients were subdivided into two ethnic groups: Chinese and Yemeni. Each ethnic group comprised 90 patients, and men and women were divided equally. Each ethnic group was classified into three skeletal classes using ANB and Wits appraisal (skeletal Classes I, II and III). Pearson's correlation coefficient was also used to assess the relationship between maxillary sinus dimensions and cephalometric parameters. RESULTS: Men had larger maxillary sinuses than women; skeletal Class II had a higher length and surface area increase than other skeletal classes, although skeletal Classes I and II were almost equal in height. Except for the maxillary sinus length, none of these findings were statistically significant. The maxillary sinuses in Chinese are larger than those in Yemenis (P = 0.000). These variables were positively correlated with SNA, SNB and Co-A. The maxillary sinus length and Co-Gn were positively correlated. The NA-APO and NA-FH angles were also correlated with the maxillary sinus surface area. However, the gonial and GoGn-Sn angles negatively affected the maxillary sinus dimension and surface area. CONCLUSIONS: Men had larger maxillary sinuses than women in both ethnic groups, and Chinese individuals had larger maxillary sinuses than Yemenis. Skeletal Class II malocclusion of both ethnicities had larger maxillary sinus dimensions. Furthermore, the maxillary sinus dimensions correlated with cephalometric parameters.


Asunto(s)
Maloclusión de Angle Clase III , Maloclusión , Masculino , Humanos , Femenino , Seno Maxilar/diagnóstico por imagen , Estudios Transversales , Pueblos del Este de Asia , Cefalometría/métodos , Maxilar/diagnóstico por imagen , Maloclusión de Angle Clase III/diagnóstico por imagen
12.
Front Bioeng Biotechnol ; 10: 812507, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35757796

RESUMEN

Purpose: To evaluate the regional corneal biomechanical deterioration with keratoconus (KC) progression as measured by the Stress-Strain Index (SSI) maps. Methods: The preoperative examinations of 29 progressive KC cases that were submitted to corneal cross-linking (CXL) were evaluated. The examinations included the tomography and the SSI measured by the Pentacam HR and the Corvis ST (Oculus, Wetzlar, Germany), respectively. The results were recorded twice, the latter of which was at the last visit before the CXL procedure. The patient-specific SSI maps were built, using data at each examination, based on finite element modelling and employing inverse analysis to represent the regional variation of biomechanical stiffness across the cornea. Results: All cases presented significant shape progression (above the 95% CI of repeatability) in anterior and posterior curvatures and minimum thickness. The overall corneal stiffness as measured by the SSI within the central 8 mm-diameter area underwent slight but significant reductions from the first to the last examination (-0.02 ± 0.02, range: -0.09 to 0, p < 0.001). In all 29 cases, the reduction in stiffness was localised and concentred in the area inside the keratoconus cone. The SSI values inside the cone were significantly lower in the last examination (by 0.15 ± 0.09, range: -0.42 to -0.01, p < 0.001), while the SSI outside the cone presented minimal, non-significant variations (0 ± 0.01, range: -0.04 to 0.01, p = 0.999). Conclusion: It has been observed through the SSI maps that the regional deterioration in stiffness was concerted inside the area of pathology, while only mild non-significant alterations were observed outside the area of pathology.

13.
Ophthalmic Physiol Opt ; 42(5): 1032-1037, 2022 09.
Artículo en Inglés | MEDLINE | ID: mdl-35708180

RESUMEN

PURPOSE: To investigate whether Pentacam densitometry readings are affected by corneal tilt. METHODS: In a prospective study, the right eyes of 86 healthy participants aged 42.8 ± 20.0 years (range 18-79 years) were imaged using Scheimpflug tomography. Elevation maps were exported to calculate corneal tilt using custom-made software, and densitometry readings were acquired directly from the corneal densitometry analysis add-on to the standard software Oculus Pentacam HR. Simple mediation analysis was applied to study age as a confounding factor in the correlation between corneal tilt and corneal densitometry. RESULTS: Corneal tilt and corneal densitometry are not independent from one another because age is significantly correlated with both corneal tilt (r = 0.50, p < 0.001) and corneal densitometry (r = 0.91, p < 0.001). Only 3.8% of the correlation between tilt and densitometry operates directly, while the remaining 96.2% depends on age. CONCLUSIONS: Corneal tilt plays a role in corneal densitometry readings, even though the interaction is strongly influenced by age. Age is a well-known factor in densitometry readings that should be taken into consideration when interpreting Scheimpflug densitometry.


Asunto(s)
Córnea , Topografía de la Córnea/métodos , Densitometría/métodos , Voluntarios Sanos , Humanos , Estudios Prospectivos
14.
Curr Eye Res ; 47(7): 982-986, 2022 07.
Artículo en Inglés | MEDLINE | ID: mdl-35385372

RESUMEN

PURPOSE: To assess the biomechanical deterioration arising from keratoconus progression in-vivo. METHODS: The preoperative examinations of 32 progressive KC cases that were submitted to corneal cross-linking were evaluated. The examinations included the corneal tomography using the Pentacam HR and biomechanical parameters assessed by the Corvis ST (Oculus, Wetzlar, Germany). The results were recorded at two time points, the latter of which was at the last visit before the CXL procedure. Keratoconus progression was characterised by a significant change in the ABCD system. RESULTS: At the last follow-up visit (41.4 ± 40.9 months) all morphological parameters of the ABCD grading system showed significant deterioration (p < 0.001). The comparative analyses revealed a significant reduction in corneal stiffness expressed by a significant reduction in the stress-strain index (SSI: -0.10 ± 0.06, p < 0.001), the Stiffness parameter A1 (SP-A1: -6.1 ± 12.0 mmHg/mm, p = 0.011), by a significant increase in the integrated Inverse Radius (IIR: 0.95 ± 1.04 mm-1, p < 0.001) and in the deflection amplitude (DA) ratio (0.23 ± 0.58, p = 0.034). A barely significant increase in the DA also pointed towards corneal stiffness reduction. (0.04 ± 0.13 mm, p = 0.056). The SSI and the IIR were the indices with the smallest overlaps between the two examinations. CONCLUSIONS: It has been demonstrated in-vivo that corneal biomechanical deterioration occurs with keratoconus progression. The larger changes observed in the SSI and the IIR when compared to the remaining biomechanical parameters suggests that these parameters could be suitable to assess the corneal stiffness reduction in keratoconus natural progression.


Asunto(s)
Queratocono , Fenómenos Biomecánicos , Córnea/cirugía , Topografía de la Córnea/métodos , Elasticidad , Humanos , Queratocono/diagnóstico , Tomografía
15.
J Cataract Refract Surg ; 48(10): 1162-1167, 2022 10 01.
Artículo en Inglés | MEDLINE | ID: mdl-35333824

RESUMEN

PURPOSE: To evaluate the characteristics of corneal material properties in healthy individuals and keratoconic patients using the stress-strain index (SSI). SETTING: Vincieye Clinic in Milan, Italy, and Instituto de Olhos Renato Ambrósio in Rio de Janeiro, Brazil. DESIGN: Retrospective observational cross-sectional study. METHODS: Records of 1221 patients were divided into 3 groups: healthy corneas (n = 728), bilateral keratoconus (KC, n = 388), and very asymmetric ectasia (VAE, n = 105) when patients presented with clinical ectasia in 1 eye and normal topography (VAE-NT) in the fellow eye. All patients were examined with Pentacam HR and Corvis ST. Severity of KC cases was stratified according to the Pentacam topographic KC classification. The SSI distribution across the different groups and its correlation with age, biomechanically corrected intraocular pressure (bIOP), and central corneal thickness (CCT) were assessed. RESULTS: A statistically significant difference between healthy individuals and each of the keratoconic groups ( P < .001) was observed, and a progressive reduction in the SSI was observed across the groups. A significant correlation was observed between the SSI and age in all groups ( P < .010) but KC severe subgroup ( P = .361). No correlation between the SSI and bIOP and CCT was observed in all KC subgroups and VAE-NT groups ( P > .050). Among healthy eyes, there was only a mild correlation between the SSI and bIOP ( R = 0.12, P = .002) and CCT ( R = 0.13, P = .001). CONCLUSIONS: This study estimates the in vivo corneal material properties in healthy individuals and patients with KC using a new method. The SSI showed a progressive deterioration within the advance in disease stages while being relatively independent of bIOP and CCT but positively correlated with age.


Asunto(s)
Queratocono , Fenómenos Biomecánicos , Brasil , Córnea , Paquimetría Corneal , Topografía de la Córnea/métodos , Estudios Transversales , Dilatación Patológica , Humanos , Queratocono/diagnóstico , Estudios Retrospectivos
16.
Bioengineering (Basel) ; 10(1)2022 Dec 28.
Artículo en Inglés | MEDLINE | ID: mdl-36671611

RESUMEN

The study aims to investigate the likelihood of Zernike polynomial being used for reconstructing rabbit corneal surfaces as scanned by the Pentacam segment tomographer, and hence evaluate the accuracy of corneal power maps calculated from such Zernike fitted surfaces. The study utilised a data set of both eyes of 21 rabbits using a reverse engineering approach for deductive reasoning. Pentacam raw elevation data were fitted to Zernike polynomials of orders 2 to 20. The surface fitting process to Zernike polynomials was carried out using randomly selected 80% of the corneal surface data points, and the root means squared fitting error (RMS) was determined for the other 20% of the surface data following the Pareto principle. The process was carried out for both the anterior and posterior surfaces of the corneal surfaces that were measured via Pentacam scans. Raw elevation data and the fitted corneal surfaces were then used to determine corneal axial and tangential curvature maps. For reconstructed surfaces calculated using the Zernike fitted surfaces, the mean and standard deviation of the error incurred by the fitting were calculated. For power maps computed using the raw elevation data, different levels of discrete cosine transform (DCT) smoothing were employed to infer the smoothing level utilised by the Pentacam device. The RMS error was not significantly improved for Zernike polynomial orders above 12 and 10 when fitting the anterior and posterior surfaces of the cornea, respectively. This was noted by the statistically non-significant increase in accuracy when the order was increased beyond these values. The corneal curvature calculations suggest that a smoothing process is employed in the corneal curvature maps outputted by the Pentacam device; however, the exact smoothing method is unknown. Additionally, the results suggest that fitting corneal surfaces to high-order Zernike polynomials will incur a clinical error in the calculation of axial and tangential corneal curvature of at least 0.16 ± 01 D and 0.36 ± 0.02 D, respectively. Rabbit corneal anterior and posterior surfaces scanned via the Pentacam were optimally fitted to orders 12 and 10 Zernike polynomials. This is essential to get stable values of high-order aberrations that are not affected by Zernike polynomial fittings, such as comas for Intracorneal Ring Segments (ICRS) adjustments or spherical aberration for pre-cataract operations. Smoothing was necessary to replicate the corneal curvature maps outputted by the Pentacam tomographer, and fitting corneal surfaces to Zernike polynomials introduces errors in the calculation of both the axial and tangential corneal curvatures.

17.
R Soc Open Sci ; 8(12): 211108, 2021 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-34950488

RESUMEN

The aim of the study was to develop an automatic segmentation approach to optical coherence tomography (OCT) images and to investigate the changes in epithelial and stromal thickness profile and radius of curvature after the use of orthokeratology (Ortho-K) contact lenses. A total of 45 right eyes from 52 participants were monitored before, and after one month of, uninterrupted overnight Ortho-K lens wear. The tomography of their right eyes was obtained using optical OCT and rotating Scheimpflug imaging (OCULUS Pentacam). A custom-built MATLAB code for automatic segmentation of corneal OCT images was created and used to assess changes in epithelial thickness, stromal thickness, corneal and stromal profiles and radii of curvature before, and after one month of, uninterrupted overnight wear of Ortho-K lenses. In the central area (0-2 mm diameter), the epithelium thinned by 12.8 ± 6.0 µm (23.8% on average, p < 0.01) after one month of Ortho-K lens wear. In the paracentral area (2-5 mm diameter), the epithelium thinned nasally and temporally (by 2.4 ± 5.9 µm, 4.5% on average, p = 0.031). The stroma thickness increased in the central area (by 4.8 ± 16.1 µm, p = 0.005). The radius of curvature of the central corneal anterior surface increased by 0.24 ± 0.26 mm (3.1%, p < 0.01) along the horizontal meridian and by 0.34 ± 0.18 mm (4.2%, p < 0.01) along the vertical meridian. There were no significant changes in the anterior and posterior stromal radius of curvature. This study introduced a new method to automatically detect the anterior corneal surface, the epithelial posterior surface and the posterior corneal surface in OCT scans. Overnight wear of Ortho-K lenses caused thinning of the central corneal epithelium. The anterior corneal surface became flattered while the anterior and posterior surfaces of the stroma did not undergo significant changes. The results are consistent with the changes reported in previous studies. The reduction in myopic refractive error caused by Ortho-K lens wear was mainly due to changes in corneal epithelium thickness profile.

18.
Sensors (Basel) ; 21(22)2021 Nov 17.
Artículo en Inglés | MEDLINE | ID: mdl-34833714

RESUMEN

Purpose: To quantify the effect of levelling the corneal surface around the optical axis on the calculated values of corneal asphericity when conic and biconic models are used to fit the anterior corneal surface. Methods: This cross-sectional study starts with a mathematical simulation proving the concept of the effect that the eye's tilt has on the corneal asphericity calculation. Spherical, conic and biconic models are considered and compared. Further, corneal asphericity is analysed in the eyes of 177 healthy participants aged 35.4 ± 15.2. The optical axis was determined using an optimization procedure via the Levenberg-Marquardt nonlinear least-squares algorithm, before fitting the corneal surface to spherical, conic and biconic models. The influence of pupil size (aperture radii of 1.5, 3.0, 4.0 and 5.0 mm) on corneal radius and asphericity was also analysed. Results: In computer simulations, eye tilt caused an increase in the apical radii of the surface with the increase of the tilt angle in both positive and negative directions and aperture radii in all models. Fitting the cornea to spherical models did not show a significant difference between the raw-measured corneal surfaces and the levelled surfaces for right and left eyes. When the conic models were fitted to the cornea, changes in the radii of the cornea among the raw-measured corneal surfaces' data and levelled data were not significant; however, significant differences were recorded in the asphericity of the anterior surfaces at radii of aperture 1.5 mm (p < 0.01). With the biconic model, the posterior surfaces recorded significant asphericity differences at aperture radii of 1.5 mm, 3 mm, 4 mm and 5 mm (p = 0.01, p < 0.01, p < 0.01 & p < 0.01, respectively) in the nasal temporal direction of right eyes and left eyes (p < 0.01, p < 0.01, p < 0.01 & p < 0.01, respectively). In the superior-inferior direction, significant changes were only noticed at aperture radii of 1.5 mm for both right and left eyes (p = 0.05, p < 0.01). Conclusions: Estimation of human corneal asphericity from topography or tomography data using conic and biconic models of corneas are affected by eyes' natural tilt. In contrast, the apical radii of the cornea are less affected. Using corneal asphericity in certain applications such as fitting contact lenses, corneal implant design, planning for refractive surgery and mathematical modelling when a geometrical centre of the eye is needed should be implemented with caution.


Asunto(s)
Córnea , Modelos Teóricos , Topografía de la Córnea , Estudios Transversales , Humanos , Matemática
19.
J Refract Surg ; 37(6): 414-421, 2021 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-34170770

RESUMEN

PURPOSE: To evaluate an automated method for detecting the cone shape characteristics and to assess the cornea specialists' subjective variability of these measures using different maps. METHODS: Topographic images of the anterior and posterior surface of each eye were presented to 12 clinicians in two different types of map: tangential curvature and relative elevation to the best-fit sphere. They were asked to mark the cone center and its boundaries in the two maps without knowing that they belonged to the same patient. The results between the maps were compared to assess the subjective variability dependent on the map type and the automated method was compared against both estimations to assess its accuracy. RESULTS: Considering the results of anterior and posterior surfaces, there was low agreement between the cone center estimations using different types of maps for 10 of the 12 cases (P < .05), whereas the comparison between the automated method and the two map estimations did not show differences in 11 of the 12 cases (P > .05). There was high variability, up to 55%, among clinicians' estimations of the cone area. The results of the automated method were within the range of the expert's estimations. CONCLUSIONS: An objective, mathematically derived method of determining morphological dimensions of the cone was consistent with clinicians' evaluations. Although there was high variability among the experts' subjective estimates, which were highly influenced by the type of map, the objective method provided a reliable evaluation of the keratoconus shape independent of maps or color scale. [J Refract Surg. 2021;37(6):414-421.].


Asunto(s)
Córnea , Queratocono , Topografía de la Córnea , Humanos , Queratocono/diagnóstico
20.
Front Bioeng Biotechnol ; 9: 640434, 2021.
Artículo en Inglés | MEDLINE | ID: mdl-33777912

RESUMEN

PURPOSE: To introduce a new method to map the mechanical stiffness of healthy and keratoconic corneas. METHODS: Numerical modeling based on the finite element method was used to carry out inverse analysis of simulated healthy and keratoconic corneas to determine the regional variation of mechanical stiffness across the corneal surface based on established trends in collagen fibril distribution. The Stress-Strain Index (SSI), developed and validated in an earlier study and presented as a parameter that can estimate the overall stress-strain behavior of corneal tissue, was adopted in this research as a measure of corneal stiffness. The regional variation of SSI across the corneal surface was estimated using inverse analysis while referring to the common features of collagen fibrils' distribution obtained from earlier x-ray scattering studies. Additionally, for keratoconic corneas, a method relating keratoconic cone features and cornea's refractive power to the reduction in collagen fibril density inside the cone was implemented in the development of SSI maps. In addition to the simulated cases, the study also included two keratoconus cases, for which SSI maps were developed. RESULTS: SSI values varied slightly across corneal surface in the simulated healthy eyes. In contrast, both simulated and clinical keratoconic corneas demonstrated substantial reductions in SSI values inside the cone. These SSI reductions depended on the extent of the disease and increased with more considerable simulated losses in fibril density in the cone area. SSI values and their regional variation showed little change with changes in IOP, corneal thickness, and curvature. CONCLUSION: SSI maps provide an estimation of the regional variation of biomechanical stiffness across the corneal surface. The maps could be particularly useful in keratoconic corneas, demonstrating the dependence of corneal biomechanical behavior on the tissue's microstructure and offering a tool to fundamentally understand the mechanics of keratoconus progression in individual patients.

SELECCIÓN DE REFERENCIAS