Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
BMC Chem ; 18(1): 105, 2024 May 29.
Artículo en Inglés | MEDLINE | ID: mdl-38812036

RESUMEN

The appearance of multidrug-resistant Gram-negative bacterial infections, along with the lack of newly discovered antibiotics, resulted in the return to old antimicrobial medications like Polymyxins. As a result, the suggested technique aims to develop a fast, environmentally friendly, and sensitive fluorimetric method for quantifying Polymyxin B. The investigated approach depends on generating a highly fluorescent derivative by a condensation pathway between the studied drug and ninhydrin in the presence of phenylacetaldehyde and then estimated spectrofluorimetrically. After the reaction conditions were well optimized, the fluorescent product was estimated at emission wavelength (λem) = 475.5 nm (following excitation at a wavelength (λex) = 386 nm. The developed calibration plot displayed rectilinear throughout the following range (0.2-3 µg mL- 1), and the calculated limit of detection and quantification were 0.062 µg mL- 1 and 0.187 µg mL- 1, respectively. As a consequence, the drug's ophthalmic and intravenous pharmaceutical forms were both successfully quantified with an excellent degree of recovery. Finally, the methodology's greenness was assessed utilizing Analytical Eco-Scale scores.

2.
Luminescence ; 39(3): e4704, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-38433336

RESUMEN

Darolutamide is an oral nonsteroidal androgen receptor antagonist used to delay the process of prostate cancer to metastatic disease and to increase the quality of life for people with advanced prostate cancer. Here, a second spectrofluorimetric method was advanced for quantifying Darolutamide in pharmaceutical formulation and spiked human plasma. This method depends on the fluorescence derivatization of Darolutamide with 4-chloro-7-nitrobenzo-2-oxa-1,3-diazole (NBD-Cl) at 75°C in a (pH 9) of borate buffer to produce a fluorescent derivative that can be detected at 520 nm after excitation at 460 nm. The method has been validated using ICH criteria, and it demonstrated linearity in the range 5-200 ng ml-1 . The limit of detection (LOD) and limit of quantitation (LOQ) were 1.15 and 3.84 nm, respectively. The proposed method was applied precisely and accurately for quantifying Darolutamide within the pharmaceutical formulation and spiking human plasma without any interferences. Moreover, the method's sustainability was evaluated and compared with the published method using two greenness assessment tools termed analytical eco-scale and Analytical GREEnness (AGREE). These findings suggest that the method is more sustainable than the published method.


Asunto(s)
4-Cloro-7-nitrobenzofurazano , Antineoplásicos , Neoplasias de la Próstata , Pirazoles , Masculino , Humanos , Composición de Medicamentos , Calidad de Vida , Espectrometría de Fluorescencia
3.
Luminescence ; 38(6): 672-679, 2023 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-37078125

RESUMEN

Pharmaceutical product quality control (QC) needs quick, sensitive and economical procedures to deliver high throughput at low cost, which is the key factor considered by such economic facilities. To lessen the risky effects of research laboratories, researchers must take into account the ecological impacts. α-Mangostin (MAG) exhibit anti-inflammatory, antioxidant, anticancer, anti-allergic, antibacterial, antifungal, antiviral and antimalarial activities. Based on the spectrofluorimetric approach, a novel straightforward, sensitive and environmentally friendly method for MAG determination was developed and validated. Many variables were investigated to improve MAG native fluorescence, including solvent type, buffers, pH and additional surfactants. The best MAG fluorescence sensitivity was found in Britton-Robinson buffer (pH 4) at 450 nm after irradiation at 350 nm in the concentration range of 5-50 ng ml-1 . The technique was successfully used to determine the presence of MAG in both its approved dose forms and in samples of spiked human plasma, as per FDA standards for validation. According to their evaluation on two recent greenness criteria (GAPI [Green Analytical Procedure Index] and AGREE [Analytical GREEnness]), the suggested approach has been shown to be environmentally beneficial because it normally uses biodegradable chemicals in solvent-free aqueous phases.


Asunto(s)
Micelas , Xantonas , Humanos , Antioxidantes/farmacología , Espectrometría de Fluorescencia/métodos , Xantonas/farmacología , Solventes
4.
RSC Adv ; 12(52): 33559-33566, 2022 Nov 22.
Artículo en Inglés | MEDLINE | ID: mdl-36505680

RESUMEN

A new, cost-effective and sensitive spectroscopic assay for the quantification of Colistin Sulfate (CS) and its prodrug colistimethate sodium (CMS) has been developed and validated. The validated technique depends on the condensation of the studied drug with 2,2-dihydroxyindan-1,3-dione (ninhydrin) and phenylacetaldehyde using Teorell and Stenhagen buffer (pH = 6) to yield a fluorescent product that is estimated at emission wavelength (λ em = 474 nm) after excitation wavelength (λ ex = 390 nm). The reaction's affecting factors were carefully studied and adjusted accurately. Over the following range (0.4-2.4 µg mL-1), the produced calibration plot looked rectilinear, and the estimated limits of detection and quantification (LOD and LOQ) were 0.051 & 0.154 µg mL-1 respectively. The recommended approach was utilized to evaluate market products containing the investigated drug. Moreover, content uniformity testing was employed as a new procedure not found in the previously reported fluorimetric technique.

5.
RSC Adv ; 12(17): 10198-10203, 2022 Mar 31.
Artículo en Inglés | MEDLINE | ID: mdl-36200125

RESUMEN

A simple, new, green, and sensitive approach was established and validated for assay of the recently approved antineoplastic medication; darolutamide (DAR) in its authentic form, pharmaceutical formulation, and biological fluids fluorimetrically. This experiment relied on the native fluorescence of the cited drug and detects the ideal solvent utilized throughout the approach. The proposed approach was validated regarding linearity, accuracy, and precision. The calibration graph showed linearity over the range of 0.1-2.0 µg mL-1. The limit of detection and quantitation (LOD and LOQ) were 0.032 µg mL-1 and 0.09 µg mL-1, respectively. Because of the approach's high sensitivity, it was decided to spike the mentioned drug in plasma and urine samples. At last, checking for content uniformity was performed regarding the United States Pharmacopoeia (USP) by adjusting the proposed approach.

6.
Luminescence ; 37(6): 971-979, 2022 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-35393741

RESUMEN

Polymyxins (PMS), namely Colistin (CS) and polymyxin B (poly B), are antimicrobial drugs that have been recently used to treat multiresistant Gram-negative bacteria infections and their resurgence, owing to a lack of new antibiotics. A speedy, simple, and ultrasensitive spectrofluorimetric screening of PMS in pharmaceutical formulations and biological fluids was urgently required from this point forwards. A reaction between fluorescamine and the aliphatic amino moiety found in both drugs was performed in a slightly alkaline borate buffer (pH 8.5) resulted in highly fluorescent products measured at λem 460 (after λex 390.5 nm). Linear calibration curves were constructed over the concentration range 70-1800 ng ml-1 and 100 to 1400 ng ml-1 , with slope values of 0.273 and 0.286, correlation coefficients of 0.9998 and 0.9997, and determination coefficient of 0.9997 and 0.9994 for poly B and CS, respectively. The ultrasensitivity of the proposed method was demonstrated by the very low limit of quantification values of 67.56 ng ml-1 and 94.89 ng ml-1 for poly B and CS, respectively. The cited drugs were successfully determined in their intravenous market preparations by the prescribed method. Moreover, due to the high sensitivity, the suggested method was used to assay the investigated drugs in biological fluids.


Asunto(s)
Antibacterianos , Polimixinas , Antibacterianos/farmacología , Colistina/farmacología , Fluorescamina , Bacterias Gramnegativas , Humanos , Preparaciones Farmacéuticas , Espectrometría de Fluorescencia/métodos
7.
J Fluoresc ; 32(2): 603-612, 2022 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-35013853

RESUMEN

Gram-negative bacteria cause infections such as skin infection, meningitis, and pneumonia in human being. Gram-negative bacteria are highly resistant to most availaible bactericidal drugs. One of the most commonly used Gram-negative bactericidal drug is Polymyxin B sulfate (PMS). In addition, it is used in cases of highly resistant Gram-negative bacterial infections. The widespread of PMS necessitate the development of an exceedingly sensitive and selective fluorimetric assay for its determination in pure form, different pharmaceutical dosage forms, and human plasma. The presented method is used to determine PMS in their dosage form (vials) and combined pharmaceutical formulations (skin and eye ointments) with a high degree of accuracy and selectivity. The described procedure relies on the structure of a derivative of a high degree of fluorescence called dihydropyridine, via the condensation of the amino moiety of PMS with two equivalents of acetylacetone in the presence of formaldehyde and Teorell buffer (pH = 3). The fluorescent product was measured at 471 nm (λex = 402 nm). The linearity ranged from 100-3000 ng mL-1 of PMS with an excellent r2 of 0.9998. LOD and LOQ were 27.16 ng mL-1 and 82.30 ng mL-1, respectively. Owing to the developed method's high selectivity, it was successfully utilized for assay of PMS, in the ointment, in the presence of oxytetracycline as an active ingredient. Furthermore, the procedure applied for the estimation of parenteral PMS in human plasma with very good mean recovery 97.42 ± 1.46.


Asunto(s)
Antibacterianos/análisis , Polimixina B/análisis , Espectrometría de Fluorescencia/métodos , Antibacterianos/administración & dosificación , Antibacterianos/sangre , Tampones (Química) , Dihidropiridinas/química , Formas de Dosificación , Colorantes Fluorescentes , Humanos , Concentración de Iones de Hidrógeno , Estructura Molecular , Polimixina B/administración & dosificación , Polimixina B/sangre , Temperatura
8.
Luminescence ; 36(5): 1249-1256, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33843139

RESUMEN

A new, accurate, nonextractive, and sensitive fluorimetric approach was proposed and validated for the first time estimation of colistin sulfate and its inactive prodrug colistimethate sodium in its bulk form, pharmaceutical formulations, and human plasma. The approach relied on condensation between acetylacetone/formaldehyde and the primary amino moiety of nonfluorescent colistin in Teorell and Stenhagen buffer (pH 2.8) by the Hantzsch reaction to form a highly fluorescent dihydropyridine derivative. The fluorescent product was measured at 460 nm (λex  = 402 nm). A plot of relative fluorescence intensity (RFI) versus concentration was rectilinear over the range 200-4000 ng ml-1 with excellent correlation (r) and determination (r2 ) coefficients of 0.9999 and 0.9998, respectively. The limit of detection (LOD) and limit of quantitation (LOQ) were 40.91 and 123.99 ng ml-1 , respectively. The present procedure was useful for determination of colistin sulfate either in powder form for suspension or in its parenteral prodrug colistimethate sodium in vial formulation. The investigated approach was applied for in vitro quantification of this drug in spiked human plasma, with a per cent mean recovery of 98.24 ± 1.34. The proposed method is reliable, selective, and does not require tedious sample pretreatment steps, expensive instrumentation, or harmful reagents, all of which make it ideally suited for use in quality control laboratories.


Asunto(s)
Colistina , Profármacos , Colistina/análogos & derivados , Formaldehído , Humanos , Espectrometría de Fluorescencia
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...