Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Electr Bioimpedance ; 15(1): 75-84, 2024 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-38947175

RESUMEN

The detection of meat quality defects can involve both subjective and objective methods. PSE-like meat is linked to a common pork defect and can be caused by rapid post-mortem damage of muscle fibers. This damage can again be linked to various factors, such as a low ultimate pH or a higher slaughter weight. PSE-like defects are characterized by discoloration, structural damage, and excessive moisture loss. However, the lack of suitable instrument-based methods makes the detection of PSE-like defects difficult, and subjective methods typically suffer from poorer reproducibility. The objective of this study was to establish how subjective visual evaluation correlates with electrical impedance spectroscopy and with traditional quality parameters. To do so, visual scoring was performed together with measurements of bioimpedance, color, and pH in two ham muscles (Adductor, Semimembranosus) for 136 animals 24-hours post-mortem. When comparing with visual scoring, Pearson correlation analysis shows the strongest correlation for bioimpedance (Py , r = -0.46, R2 = 21%), followed by pHu (r = 0.44, R2 = 19%). When using all five quality measures, i.e., Py , pHu, and CIELAB L * a * b *, the multivariate regression model had a prediction error of 0.76 for the visual scores. This was close to the error describing the subjective bias of visual scoring, more specifically the prediction error between the two observers (0.85). In all, Py showed the strongest correlation among instrument-based quality tests and alone may be used for predicting pork ham structural defects, i.e., as an instrument-based alternative for subjective, visual scoring. However, an instrument that combines Py with pH and/or L*a*b* would improve the prediction of PSE-like quality defects.

2.
Meat Sci ; 194: 108980, 2022 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-36148720

RESUMEN

During post-mortem conversion from muscle to meat, diverse quality anomalies can emerge. Recent pork defects are often accompanied by deteriorating fibre structure. Here we investigate how bioimpedance response, an indicator of structural disintegration, can help in detecting quality defects. We, first, measured the relationship between standard meat quality variables (pHu, CIELAB, drip loss) and bioimpedance (BI) response. To screen for defect-biomarkers that are linked to aberrant bioimpedance and physicochemical indicators of quality decline, we performed LC-MS/MS proteomic analysis on samples, classified with a multivariate-based separation into good versus poor quality. We found that BI correlated significantly with, e.g., colour and drip loss. Proteomics revealed eleven proteins to be unique for either, good or poor ham quality groups, and maybe linked to structural degradation. In all, our data supports a wider integration of BI testing in pork quality testing to assess structural disintegration, which can render ham unsuitable for, e.g., costly curing.


Asunto(s)
Proteómica , Espectrometría de Masas en Tándem , Cromatografía Liquida , Carne/análisis , Músculos
3.
J Electr Bioimpedance ; 13(1): 125-131, 2022 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36699663

RESUMEN

Correct food labeling is a legal requirement and helps consumers to make informed purchasing choices. Mislabeling defrosted meat as fresh is illegal in the EU. However, there are no standardized technologies to authenticate fresh versus defrosted meat. We address this by testing if bioimpedance-based measurements can separate defrosted meat from refrigerated-only meat at the end of shelf life, i.e., when also fresh meat shows deterioration. Pork sirloin samples from 20 pigs were first tested at 12 days postmortem ('fresh group'). This time point was chosen to represent a typical use-by date for refrigerated storage of fresh pork. Then, all samples were transferred to a -24°C freezer for 3 days and thawed for 2 days before final testing ('frozen-thawed group'). Bioimpedance analyses (BIA) were done in a frequency range of [102-106 Hz]. Weight, pH and electrode positioning were assessed to test for potential confounding effects. Statistics for treatment dependent differences were based on the established Py parameter and phase angle, which were extracted from the BI spectra. We found that using bioimpedance testing with tetrapolar electrodes, Py and phase angle allowed almost complete separation of fresh and previously frozen samples. However, within the whole sample population, there was some overlap between the spectra of fresh and frozen samples. Yet, based on Py, only one fresh sample (5% of Ntotal=20) fell in the lowest Py class with all the frozen samples. We used a multifactorial design that allowed to test the effects of potential confounding factors, such as electrode positioning and meat quality parameters. We found a relatively low explained variance for the Py parameter, indicating that confounding effects from other factors or quality defects in fresh pork may affect the detection capacity of bioimpedance-based authentication of fresh pork. Our data, therefore, suggest that reliable fresh-label authentication with bioimpedance testing should be based on testing a small number of samples to represent a specific lot of pork that is to be inspected.

4.
Sci Rep ; 11(1): 18082, 2021 09 10.
Artículo en Inglés | MEDLINE | ID: mdl-34508109

RESUMEN

The GABA molecule is the major inhibitory neurotransmitter in the mammalian central nervous system. Through binding to post-synaptic neurons, GABA reduces the neuronal excitability by hyperpolarization. Correct binding between the GABA molecules and its receptors relies on molecular recognition. Earlier studies suggest that recognition is determined by the geometries of the molecule and its receptor. We employed dielectric relaxation spectroscopy (DRS) to study the conformation and dielectric properties of the GABA molecule under physiologically relevant laboratory conditions. The dielectric properties of GABA investigated have given us new insights about the GABA molecule, such as how they interact with each other and with water molecules at different temperatures (22°C and 37.5°C). Higher temperature leads to lower viscosity, thus lower relaxation time. The change in the GABA relaxation time due to concentration change is more associated with the solution viscosity than with the GABA dipole moment. A resonance behavior was observed with high GABA concentrations at physiological temperature, where there might be a phase transition at a certain temperature for a given GABA concentration that leads to a sudden change of the dielectric properties.

5.
Sensors (Basel) ; 21(12)2021 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-34208559

RESUMEN

This study was performed to test bioimpedance as a tool to detect the effect of different thawing methods on meat quality to aid in the eventual creation of an electric impedance-based food quality monitoring system. The electric impedance was measured for fresh pork, thawed pork, and during quick and slow thawing. A clear difference was observed between fresh and thawed samples for both impedance parameters. Impedance was different between the fresh and the frozen-thawed samples, but there were no impedance differences between frozen-thawed samples and the ones that were frozen-thawed and then stored at +3 °C for an additional 16 h after thawing. The phase angle was also different between fresh and the frozen-thawed samples. At high frequency, there were small, but clear phase angle differences between frozen-thawed samples and the samples that were frozen-thawed and subsequently stored for more than 16 h at +3 °C. Furthermore, the deep learning model LSTM-RNN (long short-term memory recurrent neural network) was found to be a promising way to classify the different methods of thawing.


Asunto(s)
Espectroscopía Dieléctrica , Carne , Estudios de Factibilidad , Calidad de los Alimentos , Congelación , Carne/análisis
6.
J Electr Bioimpedance ; 11(1): 106-111, 2020 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-33584911

RESUMEN

Physiological saline (0.9% NaCl) and deionized water were frozen in a laboratory chest freezer and impedance was monitored throughout freezing and thawing. The resistive and reactive components of electrical impedance were measured for these samples during freezing and thawing (heating) within a temperature range between 20 °C and -48 °C. The impedance of saline solution and de-ionized water increases sharply at the freezing point, similar to what is known for, e.g., complex tissues, including meat. Yet, only the saline solution impedance shows another sharp increment at a temperature between -30 and -20 °C. Changes of the electric properties after solidification suggest that the latter is linked to transformations of the ice lattice structure. We conclude that the electrical properties might serve as sensitive indicators of these phase changes.

7.
Meat Sci ; 152: 8-19, 2019 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-30784871

RESUMEN

Novel freezing solutions are constantly being developed to reduce quality loss in meat production chains. However, there is limited focus on identifying the sensitive analytical tools needed to directly validate product changes that result from potential improvements in freezing technology. To benchmark analytical tools relevant to meat research and production, we froze pork samples using traditional (-25 °C, -35 °C) and cryogenic freezing (-196 °C). Three classes of analyses were tested for their capacity to separate different freeze treatments: thaw loss testing, bioelectrical spectroscopy (nuclear magnetic resonance, microwave, bioimpedance) and low-temperature microscopy (cryo-SEM). A general effect of freeze treatment was detected with all bioelectrical methods. Yet, only cryo-SEM resolved quality differences between all freeze treatments, not only between cryogenic and traditional freezing. The detection sensitivity with cryo-SEM may be explained by testing meat directly in the frozen state without prior defrosting. We discuss advantages, shortcomings and cost factors in using analytical tools for quality monitoring in the meat sector.


Asunto(s)
Almacenamiento de Alimentos/métodos , Congelación , Carne Roja/normas , Animales , Microscopía Electrónica de Rastreo/métodos , Músculo Esquelético/ultraestructura , Análisis Espectral/métodos , Sus scrofa
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...