Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Animals (Basel) ; 12(21)2022 Nov 02.
Artículo en Inglés | MEDLINE | ID: mdl-36359129

RESUMEN

Combretastatin A4-phosphate (CA4P) is a vascular disrupting agent that was recently described for the treatment of solid canine tumors. Conventional echocardiography and pulsed wave tissue Doppler imaging did not reveal cardiotoxicity in dogs, however, the gold standard for assessing myocardial damage in humans receiving cardiotoxic chemotherapeutics is two-dimensional speckle-tracking echocardiography. The current study evaluated the cardiotoxic effect of a single dose of CA4P in dogs using peak systolic strain measurements and the variability of these measurements. Echocardiographic examinations of seven healthy beagles and five canine cancer patients that received CA4P were retrospectively reviewed. Peak systolic regional longitudinal strain (LSt), peak systolic regional circumferential strain (CSt), and peak systolic regional radial strain (RSt) were measured before and 24 h after administration of CA4P. Peak systolic strain measurements were compared to serum cardiac troponin I (cTnI). To quantify intra- and inter-observer measurement variability, seven echocardiographic examinations were selected and each strain parameter was measured by three observers on three consecutive days. After CA4P administration, the median LSt and CSt values decreased by 21.8% (p = 0.0005) and 12.3% (p = 0.002), respectively, whereas the median RSt values were not significantly different (p = 0.70). The decrease in LSt was correlated with increased serum cTnI values (Spearman rho = -0.64, p = 0.02). The intra-observer coefficients of variation (CV) were 9%, 4%, and 13% for LSt, CSt, and RSt, respectively, while the corresponding interobserver CVs were 11%, 12%, and 20%. Our results suggest that regional peak systolic strain measurements may be useful for the early detection of cardiotoxicity that is caused by vascular disrupting agents and that LSt may be promising for the follow-up of canine cancer patients.

2.
Oncotarget ; 11(24): 2310-2326, 2020 Jun 16.
Artículo en Inglés | MEDLINE | ID: mdl-32595830

RESUMEN

Tumor-targeting contrast agents may facilitate resection of solid neoplasms during fluorescence-guided surgery. Preliminary safety and imaging efficacy of the near-infrared fluorescent probe DA364 were evaluated during surgical resection of spontaneous solid tumors in 24 dogs. Intra-operative imaging was performed in situ and on excised specimens to evaluate fluorescence intensities of tumor and adjacent tissues. After standard-of-care tumor resection, the wound bed was imaged again, and additional tissue was excised if residual fluorescence was detected. DA364 was well tolerated after intravenous administration. The median tumor-to-background ratio in situ for mammary tumors, mast cell tumors and sarcomas was 1.8 (range 1.2-3.9), 2.2 (range 1.0-5.6), and 4.2 (range 2.0-4.3), respectively. Qualitative intra-operative tumor identification was feasible in half of the cases. Remaining fluorescence was detected in four wound beds that contained residual disease, and in11 tumor-free wound beds, confirmed by histopathology. Overall, DA364 did not raise safety concerns and showed accumulation in different types of spontaneous tumors, showing potential to pinpoint residual disease. Larger clinical trials are necessary to select accurate dosing and imaging protocols for specific indications to evaluate the sensitivity and specificity of the agent.

3.
Vet Rec ; 187(7): 273, 2020 Oct 03.
Artículo en Inglés | MEDLINE | ID: mdl-32345608

RESUMEN

BACKGROUND: Near-infrared fluorescence (NIRF) imaging is a relatively novel technique that can aid surgeons during intraoperative tumour identification. METHODS: Nine canine oncology patients (five mammary gland tumours, three mast cell tumours and one melanoma) received intravenous indocyanine green (ICG). After 24 hours, tumours were resected and fluorescence intensities of tumours and surroundings were evaluated. Additional wound bed tissue was resected if residual fluorescence was present after tumour resection. Ex vivo, fluorescence-guided dissection was performed to separate tumour from surrounding tissue. RESULTS: Intraoperative NIRF-guided tumour delineation was feasible in four out of nine dogs. Wound bed imaging after tumour removal identified nine additional fluorescent lesions, of which four contained tumour tissue. One of these four true positive in vivo lesions was missed by standard-of-care inspection. Ex vivo fluorescence-guided tumour dissection showed a sensitivity of 72 per cent and a specificity of 80 per cent in discriminating between tumour and surrounding tissue. CONCLUSION: The value of ICG for intraoperative tumour delineation seems more limited than originally thought. Although NIRF imaging using ICG did identify remaining tumour tissue in the wound bed, a high false positive rate was also observed.


Asunto(s)
Enfermedades de los Perros/cirugía , Verde de Indocianina , Neoplasias/veterinaria , Cirugía Asistida por Computador/veterinaria , Animales , Perros , Femenino , Fluorescencia , Masculino , Neoplasias/cirugía , Cirugía Asistida por Computador/métodos
4.
Sci Rep ; 9(1): 9262, 2019 06 25.
Artículo en Inglés | MEDLINE | ID: mdl-31239493

RESUMEN

Combretastatin A4-phosphate (CA4P) is an anti-vascular agent which selectively shuts down blood supply in tumours, resulting in extensive tumour necrosis. The aim of this study was to assess in vivo, non-invasive ultrasound techniques for the early evaluation of tumour perfusion following CA4P treatment of spontaneous tumours. Eight dogs that bore spontaneous tumours were enrolled and were subsequently treated with a single dose of intravenous CA4P. Perfusion of tumours was evaluated by power Doppler ultrasound (PDUS) pre-treatment (0 h), during the injection (10 min, 20 min, 30 min) and after CA4P infusion (24 and 72 h). Vascularity index (VI) of the tumour tissue was quantitatively analysed and accuracy was verified by correlation analysis with the results of immunohistochemical evaluation of microvessel density (MVD). Central and peripheral perfusion was evaluated by contrast-enhanced ultrasound (CEUS) pre-treatment and at 72 h post-treatment. Post-treatment, PDUS demonstrated a significant decrease in VI within 10 min of CA4P infusion. CEUS parameters demonstrated a significant decrease in blood velocity and volume in the central aspect of the tumour. Histology revealed a 4.4-fold reduction (p < 0.001, 95% CI [2.2,9.4]) in MVD and a 4.1-fold increase (p = 0.003, 95% CI [1.4,11.8]) in necrotic tumour tissue. A strong correlation between PDUS results and immunohistochemical results was found (Pearson R2 = 0.957, p < 0.001). Furthermore, the findings of PDUS were supported by the objective results of the CEUS analyses. These data suggest a role for ultrasound in real-time, non-invasive monitoring of tumour vascular response as an early indicator of CA4P treatment efficacy.


Asunto(s)
Medios de Contraste , Neovascularización Patológica/patología , Estilbenos/farmacología , Ultrasonografía Doppler/métodos , Neoplasias Vasculares/patología , Animales , Antineoplásicos Fitogénicos/farmacología , Perros , Femenino , Masculino , Neovascularización Patológica/diagnóstico por imagen , Neovascularización Patológica/tratamiento farmacológico , Resultado del Tratamiento , Neoplasias Vasculares/diagnóstico por imagen , Neoplasias Vasculares/tratamiento farmacológico
5.
Vet Rec ; 183(11): 354, 2018 09 22.
Artículo en Inglés | MEDLINE | ID: mdl-29705740

RESUMEN

One of the major challenges in surgical oncology is the intraoperative discrimination of tumoural versus healthy tissue. Until today, surgeons rely on visual inspection and palpation to define the tumoural margins during surgery and, unfortunately, for various cancer types, the local recurrence rate thus remains unacceptably high. Near-infrared (NIR) fluorescence imaging is an optical imaging technique that can provide real-time preoperative and intraoperative information after administration of a fluorescent probe that emits NIR light once exposed to a NIR light source. This technique is safe, cost-effective and technically easy. Several NIR fluorescent probes are currently studied for their ability to highlight neoplastic cells. In addition, NIR fluorescence imaging holds great promise for sentinel lymph node mapping. The aim of this manuscript is to provide a literature review of the current organic NIR fluorescent probes tested in the light of human oncology and to introduce fluorescence imaging as a valuable asset in veterinary oncology.


Asunto(s)
Medios de Contraste , Colorantes Fluorescentes , Neoplasias/veterinaria , Espectroscopía Infrarroja Corta/veterinaria , Cirugía Asistida por Computador/veterinaria , Animales , Enfermedades de los Perros/cirugía , Perros , Oncología Médica , Neoplasias/cirugía , Compuestos Orgánicos , Espectroscopía Infrarroja Corta/métodos , Cirugía Asistida por Computador/métodos , Medicina Veterinaria
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...