Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Más filtros










Intervalo de año de publicación
1.
Front Dent ; 20: 16, 2023.
Artículo en Inglés | MEDLINE | ID: mdl-37312821

RESUMEN

Objectives: One of the most common methods used for the reconstruction of endodontically treated teeth is post and core and crown. Various factors such as the remaining tissue above the cutting margin (ferrule) affect the fracture resistance of teeth restored with post and core and crown. This study aimed to investigate the effect of ferrule/crown ratio (FCR) on the strength of maxillary anterior central teeth using finite element analysis. Materials and Methods: A 3D scan of a central incisor was obtained, and the data were transferred to Mimics software. Then, a 3D model of the tooth was designed. Next, 300N load was applied at a 135° angle to the tooth model. Force was applied to the model both horizontally and vertically. Ferrule height was considered to be 5%, 10%, 15%, 20%, and 25% in the palatal surface and 50% in the buccal surface. The length of post in the model was 11, 13, and 15mm. Results: By increasing the FCR, stress and strain distribution increased in the dental model and decreased in the post itself. As the horizontal angle of load application increased, the level of stress and strain created in the dental model increased as well. The closer the force application site to the incisal area, the higher the stress and strain would be. Conclusion: Maximum stress was inversely correlated with FCR and post length. In ratios of 20% and higher, insignificant changes occurred in stress and strain patterns in the dental model.

2.
Braz. dent. sci ; 24(1): 1-8, 2021. tab, ilus
Artículo en Inglés | BBO - Odontología, LILACS | ID: biblio-1145442

RESUMEN

Objetivo: Estudos demostraram que a zircônia monolítica um dos materiais restauradores desenvolvidos recentemente, resolveu vários problemas de restauração de zircônia. Portanto, a precisão marginal e o ajuste interno são necessários para o sucesso clinico e para a qualidade da restauração, e o espaço do cimento pode influenciar o ajuste marginal. Assim, o presente estudo teve como objetivo investigar os efeitos da espessura do cimento e o tipo de restauração na discrepância marginal. Material e métodos: foram usadas para fabricação de coroa total. Dois tipos de materiais incluindo Zirconia monolítica (Zolid) e Sintron foram usadas para produzir a coroa total. As amostras de cada grupo foram digitalizadas em laboratório dentário por um scanner 3D, projetadas e acessadas usando CAD-CAM. As amostras foram divididas em quatro grupos de cinco com espaço de 30 e 50 mícrons de cimento. Para avaliar a discrepância marginal, as coroas foram colocadas em seus respectivos dentes sem o uso de qualquer intermediário e examinados em micro-CT. Os dados foram avaliados pelo software SPSS. Resultados: Descobriu-se que a discrepância marginal do Sintron é maior que a discrepância da zircônia monolítica. Na verdade, a zircônia monolítica com espaço de 50 µm de cimento exibiu uma menor discrepância marginal, e o espaço de cimento do Sintron não influenciou significantemente na discrepância marginal. Conclusão: Concluiu-se que os tipos de material e o espaço do cimento influencia na discrepância marginal da restauração construída pelo fluxo digital (AU)


Objective: Studies demonstrated that as one of then ewly developed restorative materials, monolithic zirconia resolved several issues of zirconia restoration. Therefore, marginal accuracy and internal fit are necessary for clinical success and quality of restorations, and cement space may influence the marginal fit. Thus, the present research aimed to investigate the effects of the cement thickness and kind of restoration on the marginal discrepancy. Material and methods: In this study, 20 maxillary left first molars, prepared by DRSK Co., were used to fabricate a full crown. Two types of material included monolithic zirconia (Zolid) and Sintron were used to make a full crown. Samples from each group were scanned by dental laboratory 3D scanner and designed and processed using CAD-CAM. The samples were divided into four groups of five with 30-and 50- µm cement spaces. In order to assess the vertical marginal discrepancy, the crowns were fittedon their respective teeth without using any mediator and examined by a micro-CT scanner. Data were analyzed by SPSS software. Results: It has been found that marginal discrepancy in Sintron is higher than the discrepancy of monolithic zirconia. In fact, monolithic zirconia with 50-micron cement space exhibited the least marginal discrepancy and the cement space in Sintron did not significantly influence the marginal discrepancy. Conclusion: It has been concluded that the material kinds and cement space influence the restoration marginal discrepancy constructed by digital workflow (AU)


Asunto(s)
Adaptación Marginal Dental , Cementos Dentales , Microtomografía por Rayos X
3.
J Indian Prosthodont Soc ; 20(1): 76-82, 2020.
Artículo en Inglés | MEDLINE | ID: mdl-32089602

RESUMEN

AIM: The narrowing of the mandible during opening and protrusion movements is defined as median mandibular flexure (MMF). MMF is caused by the attachment of mandibular muscles; therefore, it can be assumed that a greater amount of maximum occlusal force (MOF) may cause more flexion and could affect the survival of dental and implant restorations. The purpose of this study was to evaluate any relationship between MOF and MMF in a sample of adults. SETTINGS AND DESIGN: In vivo - comparative study. MATERIALS AND METHODS: In this descriptive, cross-sectional, nondirectional study, a sample of 90 volunteers were recruited (45 men and 45 women). MOF was measured by applying the strain gauge receptor to the first molar region, and MMF was measured by calculating the variation in the intermolar distance by a digital caliper with an accuracy of 0.01 mm using an impression and resulted in the stone cast during the maximum opening and closed-jaw positions. The body mass index (BMI) also was calculated. STATISTICAL ANALYSIS: Data were analyzed using the SPSS software (version 23) inferential and descriptive statistics, linear regression, and Pearson correlation coefficient. P < 0.05 was considered statistically significant. RESULTS: There was no statistically significant relationship between MOF and MMF (P = 0.78), but there was a significant association between MOF and BMI (P < 0.001, r = 0.475) and gender. CONCLUSION: Although MOF and MMF are both important and effective factors in the success of prosthetic restorations, one cannot be expected by the other and both should be considered in the treatment plan separately.

4.
Implant Dent ; 25(2): 238-46, 2016 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-26914543

RESUMEN

INTRODUCTION: The aim of this in vitro study was to evaluate the effect of the type and design of the impression copings on the accuracy of implant impressions in 2 different conditions. MATERIALS AND METHODS: A reference model with 2 implants inserted in bilateral mandibular canines was fabricated. The posterior teeth were inserted as tilted to simulate intra-oral undercuts. The teeth were eliminated to create an edentulous condition. Three different impression techniques were performed (open high retentive [OH], open low retentive [OL], closed [C]) for each condition. Total of 48 casts were made. Two scan-bodies were secured on each cast, scanned by an optical scanner. Then, they were compared to the scan of the reference model, and the calculated mean errors were analyzed with a 2-way ANOVA and Tukey test. RESULTS: There was no significant difference between the complete and partially edentulous groups (F = 3.252, P = 0.079). There was significant difference between the different designs of the impression copings (F = 31.789, P < 0.001) but the interaction between the dependent variables was not significant (F = 0.511, P = 0.603). CONCLUSIONS: The design of the impression copings was more important than the undercuts. The accuracy of the closed tray coping was greater than the low retentive coping and equal to the high retentive coping.


Asunto(s)
Técnica de Impresión Dental , Diseño de Prótesis Dental/métodos , Prótesis Dental , Diente Canino , Técnica de Impresión Dental/normas , Prótesis Dental/normas , Diseño de Prótesis Dental/normas , Técnicas In Vitro , Imagen Óptica
5.
Int J Oral Maxillofac Implants ; 30(1): 26-34, 2015.
Artículo en Inglés | MEDLINE | ID: mdl-25506645

RESUMEN

PURPOSE: The success of an implant-supported prosthesis is dependent on the passive fit of its framework fabricated on a precise cast. The aim of this in vitro study was to digitally compare the three-dimensional accuracy of implant impression techniques in partially and completely edentulous conditions. MATERIALS AND METHODS: The master model simulated two clinical conditions. The first condition was a partially edentulous mandibular arch with an anterior edentulous space (D condition). Two implant analogs were inserted in bilateral canine sites. After elimination of the teeth, the model was converted to a completely edentulous condition (E condition). Three different impression techniques were performed (open splinted [OS], open unsplinted [OU], closed [C]) for each condition. Six groups of casts (DOS, DOU, DC, EOS, EOU, EC) (n = 8), totaling 48 casts, were made. Two scan bodies were secured onto the master edentulous model and onto each test cast and digitized by an optical scanning system. The related scans were superimposed, and the mean discrepancy for each cast was determined. RESULTS: The statistical analysis showed no significant difference in the accuracy of casts as a function of model status (P = .78, analysis of variance [ANOVA] test), impression technique (P = .57, ANOVA test), or as the combination of both (P = .29, ANOVA test). The distribution of data was normal (Kolmogorov-Smirnov test). CONCLUSION: Model status (dentate or edentulous) and impression technique did not influence the precision of the casts. There is no difference among any of the impression techniques in either simulated clinical condition.


Asunto(s)
Implantes Dentales , Técnica de Impresión Dental/normas , Prótesis Dental de Soporte Implantado/métodos , Imagenología Tridimensional/métodos , Análisis de Varianza , Diseño Asistido por Computadora , Diseño de Prótesis Dental , Humanos , Arcada Edéntula/rehabilitación , Arcada Parcialmente Edéntula/rehabilitación
6.
J Prosthet Dent ; 112(6): 1591-4, 2014 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-25156093

RESUMEN

This article describes a technique for relining a mandibular bar-retained overdenture that allows recording the soft tissue beneath the bar and makes it possible to replace or modify the retentive bar attachment simultaneously with the reline procedure.


Asunto(s)
Prótesis Dental de Soporte Implantado , Rebasado de Dentaduras/métodos , Retención de Dentadura/instrumentación , Prótesis de Recubrimiento , Materiales de Impresión Dental/química , Materiales Dentales/química , Bases para Dentadura , Rebasado de Dentaduras/instrumentación , Elastómeros/química , Humanos , Metilmetacrilatos/química , Polimerizacion , Propiedades de Superficie
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...