Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Adv Med Educ Pract ; 15: 189-200, 2024.
Artículo en Inglés | MEDLINE | ID: mdl-38505496

RESUMEN

Introduction: Entrustable Professional Activities (EPAs) are tasks or responsibilities within a specific field that can be given to a learner once they are competent to perform them independently. EPAs are being used in various specialty programs and serving as valuable tool to inform educational program. However, due to disparities in professional practice between different contexts, the automatic transfer of a set of core EPAs is not feasible. Hence, our study aims to develop an EPA framework to inform the Family Planning and Reproductive Health Fellowship Program in the local context of Ethiopia. Methods: We employed an exploratory mixed-method design, which involved the collection of qualitative data using the Nominal Group Technique and quantitative data through a nationwide survey in all residency training institutions across the country. Qualitative data analysis involved several steps, including compiling a list of tasks, removing duplicate tasks, reviewing EPAs using criteria and an equal rubric tool. For quantitative data analysis, descriptive statistics, validity index analysis, and intra-class correlation coefficients, were used. Results: Seven senior panelists were able to propose a total of 57 EPAs, with 17 remaining after qualitative data analysis. The panelist evaluated the relevance of each EPA in the second phase. As a result, 17 EPAs received a content validity index of >0.83, indicating satisfactory relevance. In the national survey, experts reached a high level of final agreement regarding the relevance and representativeness of all 17 EPAs (ICC = 0.815, 95% CI [0.0.756,0.865], p.0001). Conclusion: The final set of 17 end-of-training EPAs is valid, acceptable and representative of the discipline, and they can be used as a framework to inform Family planning and Reproductive Health Fellowship Program in Ethiopian medical education once these core EPA statements are described in sufficient detail. This can contribute to raise the quality of training and hence the quality of patient care.

2.
BMJ Open ; 12(8): e059372, 2022 08 02.
Artículo en Inglés | MEDLINE | ID: mdl-35918115

RESUMEN

OBJECTIVE: The study aims to determine discontinuation among long-acting reversible contraceptive users at 3, 6, 9 and 12 months after initiation and its associated factors among new long-acting reversible contraceptive (LARC) users. DESIGN: A facility-based multicentre prospective cohort study was conducted with a sample size of 1766 women. SETTING: The study was conducted in five large cities of Ethiopia (Addis Ababa, Gondar, Mekelle, Jimma and Harar) between March 2017 and December 2018. Various referral hospitals and health centres that are found in those cities are included in the study. PARTICIPANTS: The study population was all women who were new users of LARCs and initiated LARCs in our selected public health facilities during the enrolment period. INTERVENTIONS: A pretested structured questionnaire was administered at enrolment and at 6 and 12 months to determine discontinuation proportion and factors associated with discontinuation. RESULT: From the total of 1766 women sampled for the study only 1596 (90.4%) participants completed all the questionnaires including the 12-month follow-up study. The overall proportion of discontinuation of LARCs at 12 months was 21.8% (95% CI 19.8 to 23.9). The overall discontinuation proportions at 3, 6, 9 and 12 months were 2.94%, 8.53%, 3.94% and 6.36%, respectively. Location of method initiation (adjusted HR (aHR)=5.77; (95% CI 1.16 to 28.69)) and dissatisfaction with the method (aHR=0.09; (95% CI 0.03 to 0.21)) were found to be the predictors of discontinuation among intrauterine contraceptive device users. Being satisfied with the method (aHR=0.21; (95% CI 0.15 to 0.27)), initiation after post abortion (aHR=0.48; (95% CI: 0.26, 0.89)) and joint decision with partner for method initiation (aHR=0.67; (95% CI: 0.50, 0.90)) were inversely associated with implant discontinuation. CONCLUSION: The majority of LARC users discontinue the method in the first 6 months after insertion and dissatisfaction with the method increased the likelihood of removal during the first year of LARC use.


Asunto(s)
Anticonceptivos Femeninos , Anticoncepción , Etiopía , Femenino , Estudios de Seguimiento , Instituciones de Salud , Humanos , Embarazo , Estudios Prospectivos
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...