Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 14 de 14
Filtrar
2.
Foot Ankle Clin ; 26(1): 65-85, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33487244

RESUMEN

In the past several years, arthroscopic repair of the lateral ankle ligaments has grown because it has shown comparable results with the traditional open Brostrom-Gould procedure. In addition, arthroscopic repair allows reduced swelling and cosmesis. This article discusses the authors' technique for lateral ankle instability, with published data supporting biomechanical equivalency to the standard open Brostrom-Gould procedure. An optional internal brace can provide further strength to the repair and lead to a quicker recovery. Arthroscopic repair both with and without the internal brace have shown positive clinical outcomes for patients as well as high satisfaction rates.


Asunto(s)
Traumatismos del Tobillo , Inestabilidad de la Articulación , Ligamentos Laterales del Tobillo , Tobillo , Articulación del Tobillo/cirugía , Artroscopía , Humanos , Inestabilidad de la Articulación/cirugía , Ligamentos Laterales del Tobillo/cirugía
3.
Foot Ankle Int ; 42(3): 373-380, 2021 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-33161779

RESUMEN

BACKGROUND: Hallux valgus is one of the most common surgically corrected forefoot deformities. Compared to open procedures, minimally invasive (MIS) treatment of hallux valgus has resulted in decreased operative time, reduced complication rates, and greater patient satisfaction. Historically, distal chevron osteotomies are the standard for moderate hallux valgus correction. To our knowledge, no studies have evaluated biomechanical strength of transverse and chevron distal first metatarsal osteotomy (DMO) constructs. The purpose of this study was to evaluate the biomechanical strength of these techniques. METHODS: Eighteen cadaveric specimens (9 matched pairs) were randomized to transverse or chevron DMO. Each technique was performed by a separate fellowship-trained orthopedic foot and ankle surgeon. Radiographic images were analyzed. Biomechanical testing was performed using Instron Mechanical System. Ultimate load to failure, yield load, and stiffness were assessed. A 10-N preload was applied to the sesamoid bones for stability. A coaxial compression rate (10 mm/min) was applied until failure was observed. Mean and standard deviations were compared. All cadaveric specimens were male. RESULTS: There was no significant difference in percent metadiaphyseal shift between osteotomies (P = .453). The most common mode of failure was fracture at screw insertion site (55.6%), followed by failure at osteotomy site (44.4%). A trend toward increased ultimate load to failure (P = .480), yield load (P = .054), and stiffness (P = .438) among transverse compared to chevron osteotomy was observed, but this difference was not statistically significant. CONCLUSION: Biomechanical testing demonstrated no significant difference in ultimate load, yield load, and stiffness between MIS transverse and chevron osteotomy constructs; a trend toward increased strength in the transverse osteotomy cohort was observed. Chevron osteotomies may result in early failure by relative ease of cutout through cancellous bone compared to transverse osteotomies in which failure requires cortical cutout. CLINICAL RELEVANCE: Use of MIS techniques for hallux valgus correction is gaining clinical traction. Although various clinical studies have evaluated outcomes of these MIS techniques, biomechanical studies have been minimal. Specifically, the potential biomechanical benefits of various MIS hallux valgus osteotomy techniques have not been delineated to date. The content of this manuscript is quite timely, given the rise in use of these MIS techniques.


Asunto(s)
Hallux Valgus/cirugía , Procedimientos Quirúrgicos Mínimamente Invasivos/métodos , Fenómenos Biomecánicos , Estudios de Cohortes , Humanos , Osteotomía/métodos , Resultado del Tratamiento
5.
Foot Ankle Clin ; 23(4): 555-570, 2018 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-30414652

RESUMEN

Over the last 10 years, significant advances have been made and successful techniques have now been developed that effectively treat ankle instability via the arthroscope.Currently arthroscopic lateral ligament repair techniques can be grouped into "arthroscopic-assisted techniques," "all-arthroscopic techniques," and "all-inside techniques." Recent studies have proven these arthroscopic techniques to be a simple, safe, and biomechanically equivalent, stable alternative to open Brostrom Gould lateral ligament reconstruction.


Asunto(s)
Traumatismos del Tobillo/complicaciones , Articulación del Tobillo , Artroscopía , Inestabilidad de la Articulación/cirugía , Traumatismos del Tobillo/diagnóstico , Traumatismos del Tobillo/cirugía , Enfermedad Crónica , Humanos , Inestabilidad de la Articulación/diagnóstico , Inestabilidad de la Articulación/etiología
6.
Am J Sports Med ; 43(10): 2564-71, 2015 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-26306779

RESUMEN

BACKGROUND: Arthroscopic ankle lateral ligament repair techniques have recently been developed and biomechanically as well as clinically validated. Although there has been 1 anatomic study relating suture and anchor proximity to anatomic structures, none has evaluated the ArthroBroström procedure. PURPOSE: To evaluate the proximity of anatomic structures for the ArthroBroström lateral ankle ligament stabilization technique and to define ideal landmarks and "safe zones" for this repair. STUDY DESIGN: Descriptive laboratory study. METHODS: Ten human cadaveric ankle specimens (5 matched pairs) were screened for the study. All specimens underwent arthroscopic lateral ligament repair according to the previously described ArthroBroström technique with 2 suture anchors in the fibula. Three cadaveric specimens were used to test the protocol, and 7 were dissected to determine the proximity of anatomic structures. Several distances were measured, including those of different anatomic structures to the suture knots, to determine the "safe zones." Measurements were obtained by 2 separate observers, and statistical analysis was performed. RESULTS: None of the specimens revealed entrapment by either of the suture knots of the critical anatomic structures, including the superficial peroneal nerve (SPN), sural nerve, peroneus tertius tendon, peroneus brevis tendon, or peroneus longus tendon. The internervous safe zone between the intermediate branch of the SPN and sural nerve was a mean of 51 mm (range, 39-64 mm). The intertendinous safe zone between the peroneus tertius and peroneus brevis was a mean of 43 mm (range, 37-49 mm). On average, a 20-mm (range, 8-36 mm) safe distance was maintained from the most medial suture to the intermediate branch of the SPN. The amount of inferior extensor retinaculum (IER) grasped by either suture knot varied from 0 to 12 mm, with 86% of repairs including the retinaculum. CONCLUSION: The results indicate that there is a relatively wide internervous and intertendinous safe zone when performing the ArthroBroström technique for lateral ankle stabilization. While none of the critical anatomic structures was entrapped by the suture knots, it was evident that the IER was included in a majority of the repairs. This study further defines the proximity of adjacent anatomic structures and establishes the anatomic safe zones for the ArthroBroström lateral ankle stabilization procedure. CLINICAL RELEVANCE: By defining this relatively risk-free zone, surgeons who are not as experienced with arthroscopic lateral ligament repair techniques may approach arthroscopic suture passage with more confidence.


Asunto(s)
Articulación del Tobillo/cirugía , Artroscopía/métodos , Inestabilidad de la Articulación/cirugía , Ligamentos Laterales del Tobillo/cirugía , Modelos Anatómicos , Anclas para Sutura , Anciano , Cadáver , Femenino , Humanos , Masculino
7.
Foot Ankle Int ; 36(4): 465-73, 2015 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-25743426

RESUMEN

UNLABELLED: Surgical strategy regarding chronic lateral ankle instability is undergoing an evolution from traditional open procedures to minimally invasive and arthroscopic techniques. The development of arthroscopic techniques for the ankle mirrors the processes witnessed for the shoulder and knee over the last 30 years. The arthroscopic Brostrom is a novel technique that allows the surgeon to use an arthroscope to perform a lateral ankle ligament reconstruction that was previously thought possible only through open surgical technique. Indications and contraindications for the arthroscopic technique are essentially the same as those for an open Brostrom type of procedure. The arthroscopic Brostrom procedure is easy to remember and relatively simple to perform for the surgeon who has mastered basic ankle arthroscopy. The authors' results discussed in this article reveal that the arthroscopic Brostrom is a safe and effective procedure with outcomes at least equal to published results for traditional open techniques. LEVEL OF EVIDENCE: Level V, expert opinion.


Asunto(s)
Traumatismos del Tobillo/cirugía , Artroscopía/métodos , Inestabilidad de la Articulación/cirugía , Ligamentos Laterales del Tobillo/cirugía , Rango del Movimiento Articular/fisiología , Anclas para Sutura , Traumatismos del Tobillo/complicaciones , Traumatismos del Tobillo/diagnóstico por imagen , Femenino , Humanos , Inestabilidad de la Articulación/diagnóstico por imagen , Inestabilidad de la Articulación/etiología , Ligamentos Laterales del Tobillo/lesiones , Masculino , Dimensión del Dolor , Cuidados Posoperatorios/métodos , Pronóstico , Radiografía , Recuperación de la Función , Medición de Riesgo
8.
Foot Ankle Clin ; 20(1): 59-69, 2015 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-25726483

RESUMEN

Over the last 50 years, the surgical management of chronic lateral ankle ligament insufficiency has focused on 2 main categories: local soft-tissue reconstruction and tendon grafts/transfer procedures. There is an increasing interest in the arthroscopic solutions for chronic instability of the ankle. Recent biomechanical studies suggest the at least one of the arthroscopic techniques can provide equivalent results to current open local soft-tissue reconstruction (such as the modified Brostrom technique). Arthroscopic lateral ankle ligament reconstruction is becoming an increasingly acceptable method for the surgical management of chronic lateral ankle instability.


Asunto(s)
Traumatismos del Tobillo/cirugía , Articulación del Tobillo/cirugía , Inestabilidad de la Articulación/cirugía , Ligamentos Articulares/lesiones , Ligamentos Articulares/cirugía , Esguinces y Distensiones/cirugía , Traumatismos del Tobillo/fisiopatología , Articulación del Tobillo/fisiopatología , Humanos , Inestabilidad de la Articulación/fisiopatología , Técnicas de Sutura , Resultado del Tratamiento
9.
Foot Ankle Int ; 36(7): 836-41, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25767195

RESUMEN

BACKGROUND: Secondary surgical repair of ankle ligaments is often indicated in cases of chronic lateral ankle instability. Recently, arthroscopic Broström techniques have been described, but biomechanical information is limited. The purpose of the present study was to analyze the biomechanical properties of an arthroscopic Broström repair and augmented repair with a proximally placed suture anchor. It was hypothesized that the arthroscopic Broström repairs would compare favorably to open techniques and that augmentation would increase the mean repair strength at time zero. METHODS: Twenty (10 matched pairs) fresh-frozen foot and ankle cadaveric specimens were obtained. After sectioning of the lateral ankle ligaments, an arthroscopic Broström procedure was performed on each ankle using two 3.0-mm suture anchors with #0 braided polyethylene/polyester multifilament sutures. One specimen from each pair was augmented with a 2.9-mm suture anchor placed 3 cm proximal to the inferior tip of the lateral malleolus. Repairs were isolated and positioned in 20 degrees of inversion and 10 degrees of plantarflexion and loaded to failure using a dynamic tensile testing machine. Maximum load (N), stiffness (N/mm), and displacement at maximum load (mm) were recorded. RESULTS: There were no significant differences between standard arthroscopic repairs and the augmented repairs for mean maximum load and stiffness (154.4 ± 60.3 N, 9.8 ± 2.6 N/mm vs 194.2 ± 157.7 N, 10.5 ± 4.7 N/mm, P = .222, P = .685). CONCLUSIONS: Repair augmentation did not confer a significantly higher mean strength or stiffness at time zero. CLINICAL RELEVANCE: Mean strength and stiffness for the arthroscopic Broström repair compared favorably with previous similarly tested open repair and reconstruction methods, validating the clinical feasibility of an arthroscopic repair. However, augmentation with an additional proximal suture anchor did not significantly strengthen the repair.


Asunto(s)
Traumatismos del Tobillo/cirugía , Ligamentos Laterales del Tobillo/cirugía , Anclas para Sutura , Adulto , Anciano , Fenómenos Biomecánicos , Humanos , Ligamentos Laterales del Tobillo/fisiopatología , Persona de Mediana Edad
10.
Am J Sports Med ; 41(11): 2567-72, 2013 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-23982396

RESUMEN

BACKGROUND: Operative treatment of mechanical ankle instability is indicated for patients with multiple sprains and continued episodes of instability. Open repair of the lateral ankle ligaments involves exposure of the attenuated ligaments and advancement back to their anatomic insertions on the fibula using bone tunnels or suture implants. HYPOTHESIS: Open and arthroscopic fixation are equal in strength to failure for anatomic Broström repair. STUDY DESIGN: Controlled laboratory study. METHODS: Seven matched pairs of human cadaveric ankle specimens were randomized into 2 groups of anatomic Broström repair: open or arthroscopic. The calcaneofibular ligament and anterior talofibular ligament were excised from their origin on the fibula. In the open repair group, 2 suture anchors were used to reattach the ligaments to their anatomic origins. In the arthroscopic repair group, identical suture anchors were used for repair via an arthroscopic technique. The ligaments were cyclically loaded 20 times and then tested to failure. Torque to failure, degrees to failure, initial stiffness, and working stiffness were measured. A matched-pair analysis was performed. Power analysis of 0.8 demonstrated that 7 pairs needed to show a difference of 30%, with a 15% standard error at a significance level of α = .05. RESULTS: There was no difference in the degrees to failure, torque to failure, or stiffness for the repaired ligament complex. Nine of 14 specimens failed at the suture anchor. CONCLUSION: There is no statistical difference in strength or stiffness of a traditional open repair as compared with an arthroscopic anatomic repair of the lateral ligaments of the ankle. CLINICAL RELEVANCE: An arthroscopic technique can be considered for lateral ligament stabilization in patients with mild to moderate mechanical instability.


Asunto(s)
Traumatismos del Tobillo/cirugía , Ligamentos Laterales del Tobillo/cirugía , Artroscopía , Humanos , Inestabilidad de la Articulación/cirugía , Ligamentos Laterales del Tobillo/lesiones , Distribución Aleatoria , Técnicas de Sutura
12.
Foot Ankle Int ; 28(12): 1256-9, 2007 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-18173988

RESUMEN

BACKGROUND: The current study examined the outcomes of operative treatment of unstable ankle fractures in patients at least 80 years old at the time of injury. METHODS: Of 2,682 patients who presented for treatment of ankle fractures, 17 patients met the study criteria. These patients had open reduction and internal fixation after sustaining 15 closed and two open unstable ankle fractures. There were 11 type B fractures and six type C fractures by the Danis-Weber classification, and 12 supination-external rotation and five pronation-external rotation fractures by the Laugen-Hansen classification systems. RESULTS: When noncompliant patients who developed complications were removed from analysis, the fixation failure and deep infection rates were 0% each. CONCLUSIONS: These results highlight the importance of patient compliance and non-weightbearing status in the treatment of ankle fractures in patients over 80 years.


Asunto(s)
Traumatismos del Tobillo/cirugía , Fracturas Óseas/cirugía , Anciano de 80 o más Años , Falla de Equipo , Femenino , Estudios de Seguimiento , Fijación de Fractura/instrumentación , Fijación de Fractura/métodos , Fijación Interna de Fracturas/instrumentación , Fijación Interna de Fracturas/métodos , Fracturas Óseas/clasificación , Fracturas Cerradas/clasificación , Fracturas Cerradas/cirugía , Fracturas Abiertas/clasificación , Fracturas Abiertas/cirugía , Humanos , Masculino , Pronación/fisiología , Estudios Retrospectivos , Rotación , Supinación/fisiología , Dehiscencia de la Herida Operatoria/etiología , Infección de la Herida Quirúrgica/etiología , Resultado del Tratamiento , Negativa del Paciente al Tratamiento , Caminata/fisiología
13.
J Bone Joint Surg Am ; 85(12): 2425-8, 2003 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-14668514

RESUMEN

BACKGROUND: Achieving stable fixation when performing tibiotalocalcaneal arthrodesis can be challenging, especially in osteopenic bone. The purpose of the current investigation was to compare the stiffness and fatigue endurance of blade-plate-and-screw fixation with intramedullary rod fixation in a cadaveric model. METHODS: In ten matched pairs of fresh-frozen cadaveric legs, a tibiotalocalcaneal arthrodesis was performed with use of a blade-plate and a 6.5-mm sagittal screw in one leg and with use of an intramedullary rod in the contralateral leg. After an initial load-deformation curve was obtained, each specimen was loaded to 270 N through 250,000 cycles at a rate of 3 Hz. RESULTS: Blade-plate-and-screw fixation resulted in significantly higher mean initial and final stiffness and decreased plastic deformation than did intramedullary rod fixation. In addition, there was an inverse correlation between bone-mineral density and the difference in plastic deformation noted between the specimens of each pair. CONCLUSIONS: Blade-plate fixation is biomechanically superior to intramedullary fixation for tibiotalocalcaneal arthrodesis.


Asunto(s)
Artrodesis/instrumentación , Placas Óseas , Tornillos Óseos , Fijación Intramedular de Fracturas/instrumentación , Fijadores Internos , Análisis de Varianza , Artrodesis/métodos , Fenómenos Biomecánicos , Cadáver , Calcáneo/cirugía , Fuerza Compresiva , Falla de Equipo , Seguridad de Equipos , Femenino , Fijación Intramedular de Fracturas/métodos , Humanos , Masculino , Probabilidad , Sensibilidad y Especificidad , Estrés Mecánico , Tibia/cirugía
14.
Foot Ankle Int ; 23(8): 711-6, 2002 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-12199384

RESUMEN

The purposes of the current study were: 1. to analyze the relative fatigue endurance of five different first metatarsal shaft osteotomies (proximal crescentic, proximal chevron, Ludloff, Mau, and Scarf), as performed on sawbone models using the most common fixation techniques (part I); and 2. to compare the two more commonly used techniques (per part I results) in matched-pair cadaver specimens (part II). In part I, the proximal chevron and Mau osteotomies were significantly more stable (P < or = 0.005) than all other osteotomies except the Ludloff. In part II, there was no significant difference in fatigue endurance between the proximal chevron and Ludloff osteotomies.


Asunto(s)
Huesos Metatarsianos/fisiología , Huesos Metatarsianos/cirugía , Osteotomía/métodos , Análisis de Varianza , Fenómenos Biomecánicos , Cadáver , Hallux Valgus/cirugía , Humanos , Análisis por Apareamiento , Soporte de Peso
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...