Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
J Clin Microbiol ; 61(3): e0174822, 2023 03 23.
Artículo en Inglés | MEDLINE | ID: mdl-36853028

RESUMEN

In this prospective, observational, method comparison clinical study, the Xpert Xpress MVP test (MVP) was evaluated using both clinician-collected (CVS) and self-collected vaginal swabs (SVS) collected in a clinical setting. The study was conducted at 12 sites, including point-of-care (POC) settings, from geographically diverse locations in the United States. Participants were biologically female patients ≥ 14 years old with signs and/or symptoms of vaginitis/vaginosis. MVP test results for BV were compared to the BD MAX Vaginal Panel (BDVP). Results for Candida group and Candida glabrata and Candida krusei targets (species not differentiated) were assessed relative to yeast culture followed by mass spectrometry for species identification. Trichomonas vaginalis (TV) results were compared relative to a composite method that included results from the BDVP and InPouch TV culture. The investigational test demonstrated high positive percent agreement ranging from 93.6 to 99.0%, and negative percent agreement ranging from 92.1% to 99.8% for both CVS and SVS specimens, indicating it may be a valuable tool for the diagnosis of vaginitis/vaginosis in laboratory and POC settings.


Asunto(s)
Candidiasis Vulvovaginal , Vaginitis por Trichomonas , Trichomonas vaginalis , Vaginosis Bacteriana , Humanos , Femenino , Adolescente , Vaginitis por Trichomonas/diagnóstico , Candidiasis Vulvovaginal/diagnóstico , Vaginosis Bacteriana/diagnóstico , Estudios Prospectivos , Vagina , Trichomonas vaginalis/genética
2.
J Clin Microbiol ; 59(12): e0101921, 2021 11 18.
Artículo en Inglés | MEDLINE | ID: mdl-34586894

RESUMEN

Nucleic acid amplification testing (NAAT) for SARS-CoV-2 is the standard approach for confirming COVID-19 cases. This study compared results between two emergency use authorization (EUA) NAATs, with two additional EUA NAATs utilized for discrepant testing. The limits of detection (LOD) for the BD SARS-CoV-2 reagents for the BD MAX system (MAX SARS-CoV-2 assay), the bioMérieux BioFire respiratory panel 2.1 (BioFire SARS-CoV-2 assay), the Roche cobas SARS-CoV-2 assay (cobas SARS-CoV-2 assay), and the Hologic Aptima SARS-CoV-2 assay Panther (Aptima SARS-CoV-2 assay) NAAT systems were determined using a total of 84 contrived nasopharyngeal specimens with 7 target levels for each comparator. The positive and negative percent agreement (PPA and NPA, respectively) of the MAX SARS-CoV-2 assay, compared to the Aptima SARS-CoV-2 assay, was evaluated in a postmarket clinical study utilizing 708 nasopharyngeal specimens collected from suspected COVID-19 cases. Discordant testing was achieved using the cobas and BioFire SARS-CoV-2 NAATs. In this study, the measured LOD for the MAX SARS-CoV-2 assay (251 copies/ml; 95% confidence interval [CI], 186 to 427) was comparable to the cobas SARS-CoV-2 assay (298 copies/ml; 95% CI, 225 to 509) and the BioFire SARS-CoV-2 assay (302 copies/ml; 95% CI, 219 to 565); the Aptima SARS-CoV-2 assay had an LOD of 612 copies/ml (95% CI, 474 to 918). The MAX SARS-CoV-2 assay had a PPA of 100% (95% CI, 97.3% to 100.0%) and an NPA of 96.7% (95% CI, 94.9% to 97.9%) compared to the Aptima SARS-CoV-2 assay. The clinical performance of the MAX SARS-CoV-2 assay agreed with another sensitive EUA assay.


Asunto(s)
COVID-19 , SARS-CoV-2 , Prueba de COVID-19 , Humanos , Indicadores y Reactivos , Técnicas de Diagnóstico Molecular , Nasofaringe , Sensibilidad y Especificidad
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...