Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 121
Filtrar
1.
Dalton Trans ; 50(4): 1496-1506, 2021 Feb 07.
Artículo en Inglés | MEDLINE | ID: mdl-33439189

RESUMEN

The gas-phase unimolecular reactions of the silver(i) complex [Ag(PhBF3)2]-, formed via electrospray ionisation mass spectrometry of solutions containing the phenyltrifluoroborate salt and AgNO3, are examined. Upon collision induced dissociation (CID) three major reaction channels were observed for [Ag(PhBF3)2]-: Ph- group transfer via a transmetalation reaction to yield [PhAg(PhBF3)]-; F- transfer to produce [FAg(PhBF3)]-; and release of PhBF3-. The anionic silver product complexes of these reactions, [LAg(PhBF3)]- (where L = Ph and F), were then mass-selected and subjected to a further stage of CID. [PhAg(PhBF3)]- undergoes a Ph- group transfer via transmetalation to yield [Ph2Ag]- with loss of BF3. [FAg(PhBF3)]- solely fragments via loss of BF4-, a reaction that involves Ph- group transfer from B to Ag in conjunction with F- transfer from Ag to B. Density functional theory (DFT) calculations on the various competing pathways reveal that: (i) the overall endothermicities govern the experimentally observed product ion abundances; (ii) the Ph- group and F- transfer reactions proceed via late transition states; and (iii) formation of BF4- from [FAg(PhBF3)]- is a multistep reaction in which Ph- group transfer from B to Ag proceeds first to produce a [FAgPh(BF3)]- complex in which the BF3 moiety is initially weakly bound to the ipso-carbon of the phenyl group and then migrates across the linear [FAgPh]- moiety from C to Ag to F yielding [PhAg(BF4)]-, which can then dissociate via loss of PhAg.

2.
Z Kardiol ; 91 Suppl 4: 64-73, 2002.
Artículo en Inglés | MEDLINE | ID: mdl-12436755

RESUMEN

The value of the four main imaging tools: radiology, magnetic resonance imaging, echocardiography and nuclear cardiology depends in the first place on physical properties which determine the spatial, temporal and density resolution and second on the conditions under which the relevant information can be obtained with respect to the diagnostic or therapeutic problem, the comfort of the investigation, the degree of invasivity and the expenses. For several decades radiology was the only available method that allowed a look into the body. Thereby, all relevant information about diseases amenable to any surgical or conservative therapy could be attained. Parallel to the progress of cardiovascular surgery, angiocardiography could provide the anatomic and functional characteristics of congenital and acquired heart diseases. The basic principles for the measurement of total heart size, volume and shape were established already before contrast injection--initially by hand--showed the internal architecture of the heart cavities and the circulatory system. With the invention of film changers, the fundamental knowledge about all kinds of malformations of the heart and vessels was gained. Further technical progress made the procedures faster by cineangiocardiography, more comfortable by simultaneous biplane operation and easier to handle by videotechniques, allowing electronic data processing, storage and retrieval in bright operating theaters. Computer technology favored flexible image processing which, like digital subtraction and functional angiocardiography, could reduce the amount of contrast material to be injected and thereby improve the compatibility, due to better nonionic contrast material and shorter study times. Finally, computer tomography with cross sectional, or spiral data collection enabled a dynamic three-dimensional reconstruction and visualization of the beating heart and to display selected information in 'measures and numbers'. Inspite all these successes, the 'stain' of invasivity remains. Strong competition arose first in echocardiography, which--after some pioneering activities in Germany in the late 1950s--flourished in the 1970s, after being reimported from the US. Most of the rapidly increasing number of ultrasound technologies--from M-mode, via various 2D linear and sector scanning procedures in combination with continuous, pulsed and/or color Doppler methods, new contrast-echo modalities and finally 3D volume scanning procedures--can be applied without any harm in all age groups and from each competent practitioner with comparably small and cheap equipment. Only oesophageal and intravascular approaches retain a touch of invasivity. Consequently not much room remains for other techniques except those, like MRI, which can differentiate tissue properties better and with higher resolution and give unlimited access to all intrathoracic organs noninvasively. Under these conditions the indications for nuclear cardiology are restricted to the small field of myocardial perfusion and metabolic studies, whereas transit time measurements and radionuclide ventriculography are practically obsolete.


Asunto(s)
Diagnóstico por Imagen/historia , Cardiopatías/historia , Cardiología/historia , Alemania , Cardiopatías/diagnóstico , Historia del Siglo XIX , Historia del Siglo XX , Humanos
3.
Eur Heart J ; 14 Suppl E: 69-72, 1993 Sep.
Artículo en Inglés | MEDLINE | ID: mdl-8223758

RESUMEN

Arrhythmogenic substrate diagnosis has been achieved by electrophysiological studies and best localized by successful radiofrequency ablation. Pre-invasive localization procedures have been based on surface ECGs and more recently on biomagnetism, but in addition to these electric and magnetic signals a mechanical signal may be utilized: the initial site of contraction may be detected by phase analysis during radionuclide ventriculography. Generation of three-dimensional data set of phases is achieved by incorporating the new emission tomography technique. The performance of this modified phase analysis has been investigated for the detection of the normal contraction pattern during sinus rhythm, the arrhythmogenic substrate of the WPW syndrome and ventricular tachycardia, and further, to define the limitations of the method in experimental studies on pigs. In 30 out of 44 patients with normal sinus rhythm and no ventricular lesion, a characteristic phase pattern was found. Physiologically, the initial site of contraction appeared to be paraseptal and in the anterior wall of the right ventricle close to the apex. In 13 patients with WPW syndrome and in seven with ventricular tachycardia, the phase data were compared to the electrophysiological study. In 14 of 20 there was a complete match, in 3 of 20 a mechanical focus was found in the area adjacent to the electric focus. From experimental pig studies with simulated stimulation, a spatial precision of at least 20 mm was found at a pre-excitation of 20 ms.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatología , Contracción Miocárdica , Tomografía Computarizada de Emisión de Fotón Único/métodos , Animales , Estimulación Eléctrica , Humanos , Contracción Miocárdica/fisiología , Porcinos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/fisiopatología , Función Ventricular , Síndrome de Wolff-Parkinson-White/diagnóstico , Síndrome de Wolff-Parkinson-White/fisiopatología
4.
Br Heart J ; 69(3): 201-10, 1993 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-8461217

RESUMEN

A new tomographic technique combined with phase analysis was used to detect premature and ectopic ventricular contraction patterns in 15 patients with Wolff-Parkinson-White syndrome and during ventricular tachycardia in seven patients. Data generated by gated single-photon emission computed tomography (SPECT) were analysed by backprojection of the Fourier coefficients, double-angulation, and integration to thick slices containing the ventricles, thus allowing visualisation of the contraction patterns in three perpendicular views. The results were compared with those of catheter mapping. In nine patients with Wolff-Parkinson-White syndrome the site of initial contraction detected was identical with the site of the accessory pathway found by catheter mapping. The sites of origin of the ventricular tachycardias determined by catheter mapping were within 3 cm of the sites detected by the new technique. This new technique seems to be a promising non-invasive method for localising ectopic ventricular activity that will considerably shorten the time required for subsequent invasive procedures.


Asunto(s)
Corazón/diagnóstico por imagen , Ventriculografía con Radionúclidos/métodos , Tomografía Computarizada de Emisión de Fotón Único , Síndrome de Wolff-Parkinson-White/diagnóstico por imagen , Adulto , Anciano , Cateterismo Cardíaco , Ablación por Catéter , Femenino , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Taquicardia Ventricular/diagnóstico por imagen , Taquicardia Ventricular/cirugía , Síndrome de Wolff-Parkinson-White/cirugía
5.
Eur J Nucl Med ; 20(1): 59-65, 1993 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-8420785

RESUMEN

A data base of clinical studies is required for quality assurance of software used for analysis of radionuclide cardiac imaging procedures. Studies used must be rigorously validated in terms of both the clinical condition of the patient undergoing the procedure and the imaging protocol used. Selection protocols for the creation of a software phantom data base of normal studies and three typical patterns of cardiac disease--recent transmural myocardial infarction, isolated myocardial ischaemia and dilated cardiomyopathy--have been developed by the Cardiac Working Group of the European COST B2 project in association with the Cardiac Task Group of the European Association of Nuclear Medicine and the Working Group on Nuclear Cardiology of the European Society of Cardiology. These protocols include criteria for the interpretation of qualitative and quantitative non-radionuclide data. Compliance of the clinical data with the selection criteria will have to pass scrutiny by an international team for each study used as a software phantom. The radionuclide studies encompass stress and rest myocardial perfusion studies (planar and single photon emission tomography) using thallium-201 and technetium-99m methoxyisobutylisonitrile and rest gated blood pool studies. Methods for acquisition of data are defined for each type of study and for each individual study a portfolio of all clinical data is established. A pilot study is required to investigate the problems and logistics of distributing clinical radionuclide studies between a range of computers and institutes, and to ascertain the procedures necessary for analytical comparison of the results obtained.


Asunto(s)
Bases de Datos Factuales , Cardiopatías/diagnóstico por imagen , Corazón/diagnóstico por imagen , Validación de Programas de Computación , Redes de Comunicación de Computadores/organización & administración , Recolección de Datos/métodos , Imagen de Acumulación Sanguínea de Compuerta , Humanos , Proyectos Piloto , Garantía de la Calidad de Atención de Salud , Tecnecio Tc 99m Sestamibi , Radioisótopos de Talio , Tomografía Computarizada de Emisión de Fotón Único
6.
Eur J Nucl Med ; 18(3): 184-90, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-2040340

RESUMEN

The upward creep of the heart during myocardial single photon emission tomography (SPET) acquisition has been reported as a frequent source of false-positive results. The aim of this study was to simplify the detection and correction of this upward creep and to estimate its clinical relevance during routine patient care. To recognize the upward heart motion a straight line was fitted to the upper and lower border of consecutively displayed tomographic projection images. In this way, vertical translation of at least 1 pixel in size could be detected easily. On the assumption of a slow but continuous upward motion a fast interpolation correction method was developed. From 100 consecutive, supine, ergometric exercise studies, 1, 2 or 3 pixels of upward creep were found in 16, 4 or 3 patients, respectively. It was found that an upward creep of at least 2 pixels (7/100 cases) led to evident, mostly antero-septal defects on quantitative bull's-eyes, whereas only upward creeps of 3 pixels or more (3/100 cases) produced false-positive diagnostic results. The simple correction method offered a sufficient compensation of image and/or bull's-eye artefacts. These clinical findings could be reproduced in a computer model. Thus, it can be stated that clinically significant upward creep of the heart during stress SPET acquisition is relatively rare; it may have been overestimated in the past, and its artificial effects can be corrected by a quick and simple algorithm.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Procesamiento de Imagen Asistido por Computador/métodos , Tomografía Computarizada de Emisión de Fotón Único , Algoritmos , Prueba de Esfuerzo , Reacciones Falso Positivas , Femenino , Humanos , Masculino , Persona de Mediana Edad , Radioisótopos de Talio
7.
Nephron ; 57(3): 340-8, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-2017276

RESUMEN

Larger NMR magnets with relatively high field strengths have become available recently, allowing the application of magnetic resonance spectroscopy (MRS) in larger mammalian organs. The aim of this study was to develop and test a new and simple kidney perfusion model from slaughterhouse swine using a new 4.7-tesla/40-cm diameter system, with the intention behind to provide a human-like mammalian experimental kidney perfusion model, and to avoid sensitive in vivo animal experiments on higher-developed mammalians, 35 pig kidneys obtained 10-15 min post mortem were studied to evaluate and define conditions for optimum metabolic preservation with the following perfusion protocols: (1) immediate plegia with cold Collins solution, 1-3 h cold storage, P-31 MRS; (2) immediate plegia, 1-3 h cold storage, blood reperfusion, P-31 MRS; (3) immediate blood reperfusion, plegia, 1-3 h cold storage, blood reperfusion, P-31 MRS; (4) immediate blood reperfusion, plegia, 24 h cold storage, blood reperfusion, P-31 MRS, P-31 MRS at 81 MHz with a double-tuned surface coil yielded the following results: [table: see text] Blood flow showed a weak correlation with beta-ATP/inorganic phosphate in protocols 3 and 4 of r = 0.64. Repeated reperfusion and ischemia experiments of this model allowed the on-line observation of the metabolic response of the energy phosphate pattern for several hours. In conclusion, slaughterhouse-harvested swine kidneys lend themselves to a simple, low-cost in vitro perfusion model, provided they are reperfused with arterial blood immediately after harvesting.(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Riñón/metabolismo , Adenosina Trifosfato/metabolismo , Animales , Frío , Técnicas In Vitro , Riñón/irrigación sanguínea , Espectroscopía de Resonancia Magnética , Preservación de Órganos , Perfusión , Fósforo/metabolismo , Circulación Renal , Porcinos
8.
Int J Card Imaging ; 7(3-4): 225-35, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1820403

RESUMEN

Since catheter or surgical techniques for ablating the arrhythmogenic substrate in patients with SVT due to accessory pathways or those with VT are now available, exact localization of the substrate is mandatory. We report preliminary results of two new non-invasive techniques for localizing either the site of earliest ventricular contraction using ISPECT, or the site of initial ventricular depolarization by magnetocardiography (MCG) in WPW syndrome and in VT patients. Thirteen patients with WPW syndrome and 8 patients with sustained VTs were studied with ISPECT. In 9/13, comparative catheter mapping data were available. Two patients had two Kent bundles. 13/15 Kent bundles could be localized by ISPECT. In 5/9 patients the area of Kent bundle insertion was identical with ISPECT and catheter mapping, in 3 correlation was fair, and in 2 patients with 2 Kent bundles ISPECT failed to localize their insertion. In 3/8 patients with VT catheter mapping could not be performed for hemodynamic reasons. In 2/5 patients the area of VT focus was identical with both methods, in one patient it was adjacent to each other, and in 2/5 patients a larger anatomic distance of the focus was found with both methods. In 3/7 patients with WPW the MCG showed the site of Kent bundle insertion, which was identical to that seen by catheter mapping. In one patient the area was adjacent, and in 3 more distant from the site determined by catheter mapping. In 1/2 patients with 2 Kent bundles, one of these could be detected by MCG. In 1/3 patients with VT, the site of VT focus was identical with both methods, but in the remaining two a distance of 3-4 cm was observed between the area seen with MCG and that with catheter mapping. In 4 further VT patients with stable and uniform ventricular late potentials, ventricular late magnetic activity was found with different QRS lengths within the single MCG channels. From our results we conclude that both ISPECT and MCG seem to become very promising non-invasive techniques for localizing ectopic ventricular depolarization in WPW syndrome and VT patients. However, these methods have to be refined, improved and validated by further systematical studies.


Asunto(s)
Electrocardiografía/métodos , Fenómenos Electromagnéticos/métodos , Sistema de Conducción Cardíaco/fisiopatología , Ventriculografía con Radionúclidos/métodos , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico , Síndrome de Wolff-Parkinson-White/diagnóstico , Potenciales de Acción/fisiología , Adulto , Anciano , Femenino , Sistema de Conducción Cardíaco/diagnóstico por imagen , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Taquicardia por Reentrada en el Nodo Atrioventricular/diagnóstico por imagen , Taquicardia por Reentrada en el Nodo Atrioventricular/fisiopatología , Factores de Tiempo , Síndrome de Wolff-Parkinson-White/diagnóstico por imagen , Síndrome de Wolff-Parkinson-White/fisiopatología
9.
Eur J Nucl Med ; 18(1): 17-22, 1991.
Artículo en Inglés | MEDLINE | ID: mdl-1826881

RESUMEN

The quantification of myocardial perfusion abnormalities is necessary to allow comparison of repeated studies, especially in the evaluation of the success of medical, interventional or combined treatment in stable coronary artery disease or in evolving myocardial infarction. The purpose of this study was to assess inter-observer reproducibility of tomographic study processing using a semi-automatic quantitative programme. Technetium 99m hexakis-2-methoxyisobutylisonitrile (99mTc-Sestamibi) was chosen for tomographic imaging of repeated rest-stress studies in patients with stable coronary artery disease. The quantification was performed using a modification of the Cedars polar coding and comparison with the normal data base. The perfusion defects were quantified separately for each standard perfusion area [left anterior descending (LAD), right coronary (RCA) and left circumflex (LCX) arteries] and total area of hypoperfused myocardium. The inter-observer variability for 40 tomographic studies was accomplished. The defects were the largest in the LAD perfusion area (average 19.7% of the normalized LAD supply area) with an inter-observer correlation of 0.84 for this region. The greatest variability was found for the LCX region (r = 0.55) and is attributed to a small average perfusion defect (7.1%), only 18 studies having abnormal perfusion in this area. In total, an average 14.3% of the left ventricular myocardium was significantly hypoperfused, and the inter-observer correlation was 0.87. These results show good inter-observer reproducibility using semi-automatic quantitation of perfusion defects. Careful interpretation of smaller defects in the evaluation of treatment results is advised when repeated 99mTc-Sestamibi single photon emission tomography studies are processed by more than one observer.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Compuestos de Organotecnecio , Tomografía Computarizada de Emisión de Fotón Único , Enfermedad Coronaria/epidemiología , Femenino , Corazón/diagnóstico por imagen , Humanos , Masculino , Persona de Mediana Edad , Nitrilos , Variaciones Dependientes del Observador , Reproducibilidad de los Resultados , Tecnecio Tc 99m Sestamibi
10.
J Nucl Med ; 31(12): 1940-4, 1990 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-2125066

RESUMEN

A carbon-14 (14C) urea breath test for detecting Helicobacter pylori with multiple breath sampling was developed. Carbon-14-urea (110 kBq) administered orally to 18 normal subjects and to 82 patients with Helicobacter infection. The exhaled 14C-labeled CO2 was trapped at 10-min intervals for 90 min. The total 14C activity exhaled over 90 min was integrated and expressed in %activity of the total dose given. In normals, a mean of 0.59% +/- 0.24% was measured, resulting in an upper limit of normal of 1.07%. In 82 patients, a sensitivity of 90.2%, a specificity of 83.8%, and a positive predictive value of 90.2% was found. The single probes at intervals of 40-60 min correlated best with the integrated result, with r ranging from 0.986 to 0.990. The test's diagnostic accuracy did not change at all when reevaluated with the 40-, 50-, or 60-min sample data alone. Thus, the 14C-urea breath test can be applied routinely as a noninvasive, low-cost and one-sample test with high diagnostic accuracy in detecting Helicobacter pylori colonization.


Asunto(s)
Pruebas Respiratorias , Dióxido de Carbono/análisis , Radioisótopos de Carbono , Infecciones por Helicobacter/microbiología , Helicobacter pylori/clasificación , Urea , Adulto , Anciano , Femenino , Humanos , Masculino , Persona de Mediana Edad
11.
J Nucl Med ; 31(11): 1856-61, 1990 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-2231002

RESUMEN

Gated SPECT (GASPECT) during radionuclide ventriculography (RNV) is a time-consuming procedure requiring extended hard- and software. Furthermore, the procedure suffers from poor count statistics. Our method tries to overcome these difficulties by exploiting the count summation effect of Fourier analysis. The sine and cosine coefficients of the first harmonic are extracted from the gated views and reconstructed. This, in fact, results in an improvement of the count statistics by a factor of four combined with a tremendous reduction of disc space requirements. Using short-axis slices, bull's-eye plots of the amplitude and phase of the left ventricle are calculated. Cardiac functions and localization and extent of any malfunction are documented three-dimensionally without superposition.


Asunto(s)
Interpretación Estadística de Datos , Análisis de Fourier , Imagen de Acumulación Sanguínea de Compuerta/estadística & datos numéricos , Humanos , Tomografía Computarizada de Emisión de Fotón Único
13.
Nuklearmedizin ; 29(4): 144-52, 1990 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-2216809

RESUMEN

Timing of aortic valve replacement (AVR) in chronic aortic regurgitation (AR) remains a difficult problem in clinical practice. Radionuclide ventriculography (RNV) yields information on the extent of valvular regurgitation, the enlargement and the systolic function of the left ventricle. A "well-timed" AVR is defined by 1) postoperative improvement of clinical symptoms, decrease in left ventricular end-diastolic volume (EDV) and normalization of ejection fraction (EF) as well as by 2) greater improvement under surgical therapy as compared to conservative management. In "too early" AVR the latter condition is not fulfilled, while in "too late" AVR the first condition is not accomplished. In this study 54 patients with chronic aortic incompetence were evaluated by RNV to see whether these three groups ("too early", "well timed", "too late" AVR, resp.) can be separated by the relation between EDV and regurgitant volume (RV), the level of the EDV and the clinical status. The examination was based on pre- and postoperative RNV studies as well as on follow-up studies. A good postoperative result can be expected in cases with a preoperative EDV/RV-ratio similar to that observed in 30 patients with AR in whom AVR was not indicated. In contrast, in the majority of those cases with an EDV/RV-ratio exceeding this normal range the postoperative outcome will be unsatisfactory. If the EDV/RV-ratio is normal, AVR should be performed in cases with an EDV exceeding 400 ml, while in cases with an EDV between 300-400 ml AVR is only indicated in the presence of additional symptoms (NYHA greater than or equal to II).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Imagen de Acumulación Sanguínea de Compuerta , Prótesis Valvulares Cardíacas , Adulto , Anciano , Válvula Aórtica/cirugía , Insuficiencia de la Válvula Aórtica/cirugía , Enfermedad Crónica , Femenino , Humanos , Masculino , Persona de Mediana Edad
14.
Z Kardiol ; 79(8): 529-34, 1990 Aug.
Artículo en Alemán | MEDLINE | ID: mdl-1699364

RESUMEN

In planar radionuclide ventriculography (RNV) identification of the site of initial contraction is possibly by the Fourier phase. First clinical experiences will be presented with a new integrated tomographic technique--ISPECT--in noninvasively assessing the site of ectopic or premature ventricular depolarization. In six patients Fourier phases of RNV and ISPECT were performed and compared in five with results from the corresponding electrophysiologic study. It was possible to exactly localize the beginning of mechanical contraction in the two orthogonal planes: during pacemaker stimulation at the apex of the right ventricle, at the lateral border of a large aneurysm during ventricular tachycardia, and at the site of three of five WPW bundles. In the other two bundles the site of first contraction was near the area found during invasive mapping procedure. Thus, this new ISPECT approach together with planar radionuclide imaging may help in noninvasively localizing the site of ectopic and premature depolarization in addition to surface ECG.


Asunto(s)
Complejos Cardíacos Prematuros/diagnóstico por imagen , Ventriculografía con Radionúclidos/métodos , Tomografía Computarizada de Emisión de Fotón Único , Adulto , Anciano , Complejos Cardíacos Prematuros/fisiopatología , Estimulación Cardíaca Artificial , Femenino , Análisis de Fourier , Humanos , Masculino , Persona de Mediana Edad , Taquicardia/diagnóstico por imagen , Síndrome de Wolff-Parkinson-White/diagnóstico por imagen
15.
Nuklearmedizin ; 29(3): 109-12, 1990 Jun.
Artículo en Alemán | MEDLINE | ID: mdl-2392371

RESUMEN

The suitability of a 3-dimensional filter in diminishing the statistical noise of left ventricular volume curves without any systematical error in the left ventricular ejection fraction (EF) was investigated. The EF values were compared in 50 studies on 24 patients. There was no significant systematical difference between the EFs before and after filtering. The filter diminishes the statistical uncertainty of the EF by a factor of 0.47. Therefore, the method may possibly be employed in processing the left ventricular volume curves.


Asunto(s)
Procesamiento Automatizado de Datos , Imagen de Acumulación Sanguínea de Compuerta/métodos , Volumen Sistólico , Adulto , Anciano , Femenino , Filtración/instrumentación , Imagen de Acumulación Sanguínea de Compuerta/instrumentación , Humanos , Masculino , Persona de Mediana Edad
16.
Eur J Nucl Med ; 16(2): 97-101, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2311624

RESUMEN

The exact regional correlation of findings of facial bone scans, planar or SPECT, to dental orthopan X-ray films (OPT) is difficult because of the very different projection techniques. To improve correlative imaging in this regard a projection algorithm was developed that uses SPECT data of the skull for reconstructing an orthopan tomoscintigraphic projection. Fourteen conventional SPECT slices of the upper and lower jaws were obtained during bone scanning. All mandibular slices were superimposed resulting in a horseshoe shaped structure, while was marked by an ROI which was divided into segments. All 14 SPECT slices were then masked by this segmental ROI, thereby marking the teeth-carrying bone in all slices. The information from this horseshoe like ROI is then transformed into lines. Line by line arrangement results in an orthopan projection, the orthopan tomoscintigram. This new display allows 1:1 true scale superimposition with the X-ray OPT and markedly facilitates correlative imaging.


Asunto(s)
Huesos Faciales/diagnóstico por imagen , Medronato de Tecnecio Tc 99m , Tomografía Computarizada de Emisión de Fotón Único , Humanos , Procesamiento de Imagen Asistido por Computador , Mandíbula/diagnóstico por imagen , Maxilar/diagnóstico por imagen
17.
Eur J Clin Pharmacol ; 38 Suppl 1: S31-4, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2354712

RESUMEN

The effect of a controlled-release formulation of isosorbide-5-mononitrate (IS-5-MN) was studied in patients with coronary heart disease (CHD), with the aim of comparing the acute effect with that after chronic administration on parameters of ischemia. To determine whether any tolerance developed, several aspects of ischemia were observed: ECG signs, clinical parameters, and left ventricular function. Fifteen patients with angiographically proven CHD were examined with 12-lead exercise ECG before, 2 h and 4 h after the first dose and after 10 days of therapy with 60 mg IS-5-MN (Coleb-Duriles) once daily. After 7 days, three radionuclide ventriculographies were performed: control, 2 h after nitrate and 2 h after 75 mg gallopamil. Plasma concentrations of IS-5-MN were measured before every exercise test. The results showed a reduction of total ST-segment depression from 0.59 mV to 0.29 mV after 2 h (NS) and 4 h (P less than 0.05) on the 1st day and from 0.48 mV to 0.32 mV (P less than 0.05) and 0.31 mV (NS) after 10 days. The severity of angina pectoris was diminished by about 50%. The effect on exercise duration and time to ST-segment depression by more than 0.1 mV remained unchanged after 10 days, whereas the effect on blood pressure, heart rate and time to onset of angina was attenuated. The mean decrease in ejection fraction (EF) from rest to exercise was reduced from--5.9% to -1.9% (P less than 0.05) after nitrate, while an increase of +1.4% was seen after gallopamil (P less than 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)


Asunto(s)
Angina de Pecho/tratamiento farmacológico , Galopamilo/uso terapéutico , Dinitrato de Isosorbide/análogos & derivados , Adulto , Anciano , Angina de Pecho/sangre , Angina de Pecho/diagnóstico por imagen , Angina de Pecho/fisiopatología , Presión Sanguínea/efectos de los fármacos , Preparaciones de Acción Retardada , Interacciones Farmacológicas , Quimioterapia Combinada , Tolerancia a Medicamentos , Electrocardiografía/efectos de los fármacos , Femenino , Galopamilo/sangre , Frecuencia Cardíaca/efectos de los fármacos , Humanos , Dinitrato de Isosorbide/administración & dosificación , Dinitrato de Isosorbide/sangre , Masculino , Persona de Mediana Edad , Ventriculografía con Radionúclidos/efectos de los fármacos
18.
Clin Physiol Biochem ; 8(1): 38-52, 1990.
Artículo en Inglés | MEDLINE | ID: mdl-2138947

RESUMEN

Timing of valve replacement (AVR) in chronic aortic regurgitation remains a difficult problem in clinical practice. When the disease takes a favorable natural course, this may be attributed to excellent compensatory mechanisms - especially an increase in left ventricular end-diastolic volume (LVEDV) in relation to regurgitant volume (RV) - whereas a rapid clinical and hemodynamic deterioration may usually be ascribed to a vicious circle consisting in a marked increase in afterload leading to an increase in LVEDV and so on. 54 patients with aortic regurgitation underwent pre- and postoperative as well as long-term follow-up radionuclide ventriculographic (RNV) studies in order to determine LVEDV and RV and to measure left ventricular ejection fraction (LVEF). These measures were expected to provide information on 'physiologic' LVEDV elevation in relation to RV. Our results indicate that if LVEDV exceeds 300-400 ml there may be an increase in afterload for LV. Factors counteracting this increased afterload (LV hypertrophy, increased diastolic stretching) will eventually preserve LVEF and keep LVEDV/RV within the normal range, but are accompanied by an elevation of LV filling pressure leading to dyspnea on exertion. With an LVEDV exceeding 400-500 ml these factors generally cannot prevent the initiation of the above mentioned vicious circle. Hence, in these severely symptomatic cases LVEDV/RV exceeds the normal range and LVEF becomes markedly depressed. An unfavorable postoperative result must be expected in these patients, while the postoperative result will be good in cases with an LVEDV/RV within the normal range. Hence, we conclude that AVR should ideally be performed in those patients with an EDV exceeding 300 ml, who still have an LVEDV/RV within the normal range, but who show clinical symptoms and/or an only moderately depressed LVEF, indicating that the limits of the compensatory mechanism are reached. The indications for AVR in other conditions characterized by the clinical status, the level of the LVEDV and LVEDV/RV are discussed.


Asunto(s)
Insuficiencia de la Válvula Aórtica/cirugía , Prótesis Valvulares Cardíacas , Adulto , Válvula Aórtica , Insuficiencia de la Válvula Aórtica/diagnóstico por imagen , Insuficiencia de la Válvula Aórtica/fisiopatología , Cardiomegalia/diagnóstico por imagen , Cardiomegalia/fisiopatología , Femenino , Hemodinámica , Humanos , Masculino , Persona de Mediana Edad , Ventriculografía con Radionúclidos , Volumen Sistólico , Factores de Tiempo
20.
Dtsch Med Wochenschr ; 114(37): 1397-401, 1989 Sep 15.
Artículo en Alemán | MEDLINE | ID: mdl-2776665

RESUMEN

Electrocardiograms and radionuclide ventriculograms were obtained at rest and on exercise in 23 patients (20 men and 3 women, mean age 53.4 years) with exercise-dependent myocardial ischaemia after infarction, as well as in 22 persons (17 men and 5 women, mean age 43 years) without clinical, electrocardiographic and biochemical evidence of coronary heart disease. Among the ischaemia patients exercise-dependent loss of motility, as measured by regional ejection fraction and Fourier amplitude, occurred in 95% (50% of controls) in one sector, in 78% (4.5% of controls) in the two sectors with the highest contractility at rest, and in 74% (0% of controls) in three sectors. On exercise, phase shifts occurred in 87% (27% of controls). When combining the exercise-ECG, global ejection fraction as well as regional motility loss in one sector, in the two sectors with the highest contractility at rest and in three sectors, at least two of the five criteria of abnormality were present in 91.3% of the ischaemia patients, compared with at most one criterion in 90.9% of controls. The results indicate the greater diagnostic value of regional than global measures of ventricular function and emphasize the importance of radionuclide ventriculography as an addition to exercise electrocardiography in the pre-invasive diagnosis of coronary heart disease.


Asunto(s)
Enfermedad Coronaria/diagnóstico por imagen , Corazón/diagnóstico por imagen , Esfuerzo Físico , Volumen Sistólico , Adulto , Anciano , Enfermedad Coronaria/fisiopatología , Prueba de Esfuerzo , Femenino , Análisis de Fourier , Corazón/fisiopatología , Ventrículos Cardíacos/diagnóstico por imagen , Ventrículos Cardíacos/fisiopatología , Humanos , Masculino , Persona de Mediana Edad , Contracción Miocárdica , Cintigrafía , Tecnecio
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA