Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 23
Filtrar
1.
Curr Oncol Rep ; 2024 Apr 22.
Artículo en Inglés | MEDLINE | ID: mdl-38647995

RESUMEN

PURPOSE OF REVIEW: To provide an update on the current state of percutaneous thermal ablation in the treatment of sarcoma. RECENT FINDINGS: Data continue to accrue in support of ablation for local control and palliation of specific sarcoma subtypes such as extra-abdominal desmoid fibromatosis and for broader indications such as the treatment of oligometastatic disease. The synergistic possibilities of various combination therapies such as cryoablation and immunotherapy represent intriguing areas of active investigation. Histotripsy is an emerging non-invasive, non-thermal ablative modality that may further expand the therapeutic arsenal for sarcoma treatment. Percutaneous thermal ablation is a valuable tool in the multidisciplinary management of sarcoma, offering a minimally invasive adjunct to surgery and radiation therapy. Although there remains a paucity of high-level evidence specific to sarcomas, ablation techniques are demonstrably safe and effective for achieving local tumor control and providing pain relief in select patients and are of particular benefit in those with metastatic disease or requiring palliative care.

2.
Med Phys ; 51(6): 4231-4242, 2024 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-38353644

RESUMEN

BACKGROUND: Computed tomography (CT) is routinely used to guide cryoablation procedures. Notably, CT-guidance provides 3D localization of cryoprobes and can be used to delineate frozen tissue during ablation. However, metal-induced artifacts from ablation probes can make accurate probe placement challenging and degrade the ice ball conspicuity, which in combination could lead to undertreatment of potentially curable lesions. PURPOSE: In this work, we propose an image-based neural network (CNN) model for metal artifact reduction for CT-guided interventional procedures. METHODS: An image domain metal artifact simulation framework was developed and validated for deep-learning-based metal artifact reduction for interventional oncology (MARIO). CT scans were acquired for 19 different cryoablation probe configurations. The probe configurations varied in the number of probes and the relative orientations. A combination of intensity thresholding and masking based on maximum intensity projections (MIPs) was used to segment both the probes only and probes + artifact in each phantom image. Each of the probe and probe + artifact images were then inserted into 19 unique patient exams, in the image domain, to simulate metal artifact appearance for CT-guided interventional oncology procedures. The resulting 361 pairs of simulated image volumes were partitioned into disjoint training and test datasets of 304 and 57 volumes, respectively. From the training partition, 116 600 image patches with a shape of 128 × 128 × 5 pixels were randomly extracted to be used for training data. The input images consisted of a superposition of the patient and probe + artifact images. The target images consisted of a superposition of the patient and probe only images. This dataset was used to optimize a U-Net type model. The trained model was then applied to 50 independent, previously unseen CT images obtained during renal cryoablations. Three board-certified radiologists with experience in CT-guided ablations performed a blinded review of the MARIO images. A total of 100 images (50 original, 50 MARIO processed) were assessed across different aspects of image quality on a 4-point likert-type item. Statistical analyses were performed using Wilcoxon signed-rank test for paired samples. RESULTS: Reader scores were significantly higher for MARIO processed images compared to the original images across all metrics (all p < 0.001). The average scores of the overall image quality, iceball conspicuity, overall metal artifact, needle tip visualization, target region confidence, and worst metal artifact, needle tip visualization, iceball conspicuity, and target region confidence improved by 34.91%, 36.29%, 39.94%, 34.17%, 35.13%, and 45.70%, respectively. CONCLUSIONS: The proposed method of image-based metal artifact simulation can be used to train a MARIO algorithm to effectively reduce probe-related metal artifacts in CT-guided cryoablation procedures.


Asunto(s)
Artefactos , Procesamiento de Imagen Asistido por Computador , Metales , Tomografía Computarizada por Rayos X , Procesamiento de Imagen Asistido por Computador/métodos , Redes Neurales de la Computación , Humanos , Cirugía Asistida por Computador/métodos , Aprendizaje Profundo , Criocirugía/métodos , Fantasmas de Imagen
3.
J Am Coll Radiol ; 21(3): 387-397, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37838189

RESUMEN

PURPOSE: The aim of this study was to evaluate the utility of cancer detection rate (CDR) and abnormal interpretation rate (AIR) in prostate MRI for patients with low-grade prostate cancer (PCa). METHODS: This three-center retrospective study included patients who underwent prostate MRI from 2017 to 2021 with known low-grade PCa (Gleason score 6) without prior treatment. Patient-level highest Prostate Imaging Reporting & Data System (PI-RADS®) score and pathologic diagnosis within 1 year after MRI were used to evaluate the diagnostic performance of prostate MRI in detecting clinically significant PCa (csPCa; Gleason score ≥ 7). The metrics AIR, CDR, and CDR adjusted for pathologic confirmation rate were calculated. Radiologist-level AIR-CDR plots were shown. Simulation AIR-CDR lines were created to assess the effects of different diagnostic performances of prostate MRI and the prevalence of csPCa. RESULTS: A total of 3,207 examinations were interpreted by 33 radiologists. Overall AIR, CDR, and CDR adjusted for pathologic confirmation rate at PI-RADS 3 to 5 (PI-RADS 4 and 5) were 51.7% (36.5%), 22.1% (18.8%), and 30.7% (24.6%), respectively. Radiologist-level AIR and CDR at PI-RADS 3 to 5 (PI-RADS 4 and 5) were in the 36.8% to 75.6% (21.9%-57.5%) range and the 16.3%-28.7% (10.9%-26.5%) range, respectively. In the simulation, changing parameters of diagnostic performance or csPCa prevalence shifted the AIR-CDR line. CONCLUSIONS: The authors propose CDR and AIR as performance metrics in prostate MRI and report reference performance values in patients with known low-grade PCa. There was variability in radiologist-level AIR and CDR. Combined use of AIR and CDR could provide meaningful feedback for radiologists to improve their performance by showing relative performance to other radiologists.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Próstata/patología , Neoplasias de la Próstata/patología , Estudios Retrospectivos , Imagen por Resonancia Magnética/métodos , Clasificación del Tumor
4.
J Am Coll Radiol ; 21(3): 398-408, 2024 Mar.
Artículo en Inglés | MEDLINE | ID: mdl-37820833

RESUMEN

PURPOSE: To report cancer detection rate (CDR) and abnormal interpretation rate (AIR) in prostate MRI performed for clinical suspicion of prostate cancer (PCa). MATERIALS AND METHODS: This retrospective single-institution, three-center study included patients who underwent MRI for clinical suspicion of PCa between 2017 and 2021. Patients with known PCa were excluded. Patient-level Prostate Imaging-Reporting and Data System (PI-RADS) score was extracted from the radiology report. AIR was defined as number of abnormal MRI (PI-RADS score 3-5) / total number of MRIs. CDR was defined as number of clinically significant PCa (csPCa: Gleason score ≥7) detected at abnormal MRI / total number of MRI. AIR, CDR, and CDR adjusted for pathology confirmation rate were calculated for each of three centers and pre-MRI biopsy status (biopsy-naive and previous negative biopsy). RESULTS: A total of 9,686 examinations (8,643 unique patients) were included. AIR, CDR, and CDR adjusted for pathology confirmation rate were 45.4%, 23.8%, and 27.6% for center I; 47.2%, 20.0%, and 22.8% for center II; and 42.3%, 27.2%, and 30.1% for center III, respectively. Pathology confirmation rate ranged from 81.6% to 88.0% across three centers. AIR and CDR for biopsy-naive patients were 45.5% to 52.6% and 24.2% to 33.5% across three centers, respectively, and those for previous negative biopsy were 27.2% to 39.8% and 11.7% to 14.2% across three centers, respectively. CONCLUSION: We reported CDR and AIR in prostate MRI for clinical suspicion of PCa. CDR needs to be adjusted for pathology confirmation rate and pre-MRI biopsy status for interfacility comparison.


Asunto(s)
Próstata , Neoplasias de la Próstata , Masculino , Humanos , Neoplasias de la Próstata/diagnóstico por imagen , Imagen por Resonancia Magnética , Estudios Retrospectivos , Biopsia , Biopsia Guiada por Imagen
5.
Australas J Ultrasound Med ; 26(4): 267-271, 2023 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-38098616

RESUMEN

Introduction/Purpose: Percutaneous core-needle biopsy of the testicle has been shown to be a safe and effective method of obtaining tissue for histological analysis and can be considered in specific clinical scenarios. While the use of spermatic cord block has been shown to be effective in pain relief in the emergent setting and as an anaesthetic option for inguinal surgery, its use in percutaneous core-needle biopsy has not been well described. Through this case series, we present our experience and technique of ultrasound-guided percutaneous core-needle biopsy using spermatic cord block in the setting of indeterminant testicular masses. Methods: Our departmental biopsy database was reviewed to identify patients who underwent percutaneous core-needle biopsy of the testicle from March 2010 to July 2022 and who also received spermatic cord block during the procedure. Results: Three patients were identified who met the search criteria. All three patients presented for the evaluation of indeterminant testicular mass and had a known non-testicular primary cancer diagnosis at the time of biopsy. All three biopsies were performed using a combination of spermatic cord block, moderate sedation, and local anaesthetic. Biopsies were obtained using an 18-gauge spring-loaded device with 4-5 core samples obtained during each procedure. All biopsies were well tolerated without significant pain or post-procedure complications. Discussion: Ultrasound-guided percutaneous core-needle testicular biopsy using spermatic cord block is a safe and effective option in sampling indeterminate testicular masses while maintaining patient comfort. Conclusion: The inclusion of a spermatic cord block in combination with local anaesthetic and moderate sedation has become standard practice in our institution, as we believe this maximises patient comfort and safety resulting in a better patient experience.

6.
Eur Radiol ; 2023 Oct 27.
Artículo en Inglés | MEDLINE | ID: mdl-37889268

RESUMEN

OBJECTIVES: To evaluate the impact of susceptibility artifacts from hip prosthesis on cancer detection rate (CDR) in prostate MRI. MATERIALS AND METHODS: This three-center retrospective study included prostate MRI studies for patients without known prostate cancer between 2017 and 2021. Exams with hip prosthesis were searched on MRI reports. The degree of susceptibility artifact on diffusion-weighted images was retrospectively categorized into mild, moderate, and severe (> 66%, 33-66%, and < 33% of the prostate volume are evaluable) by blind reviewers. CDR was defined as the number of exams with Gleason score ≥7 detected by MRI (PI-RADS ≥3) divided by the total number of exams. For each artifact grade, control exams without hip prosthesis were matched (1:6 match), and CDR was compared. The degree of CDR reduction was evaluated with ratio, and influential factors were evaluated by expanding the equation. RESULTS: Hip arthroplasty was present in 548 (4.8%) of the 11,319 MRI exams. CDR of the cases and matched control exams for each artifact grade were as follows: mild (n = 238), 0.27 vs 0.25, CDR ratio = 1.09 [95% CI: 0.87-1.37]; moderate (n = 143), 0.18 vs 0.27, CDR ratio = 0.67 [95% CI: 0.46-0.96]; severe (n = 167), 0.22 vs 0.28, CDR ratio = 0.80 [95% CI: 0.59-1.08]. When moderate and severe artifact grades were combined, CDR ratio was 0.74 [95% CI: 0.58-0.93]. CDR reduction was mostly attributed to the increased frequency of PI-RADS 1-2. CONCLUSION: With moderate to severe susceptibility artifacts from hip prosthesis, CDR was decreased to 74% compared to the matched control. CLINICAL RELEVANCE STATEMENT: Moderate to severe susceptibility artifacts from hip prosthesis may cause a non-negligible CDR reduction in prostate MRI. Expanding indications for systematic prostate biopsy may be considered when PI-RADS 1-2 was assigned. KEY POINTS: • We proposed cancer detection rate as a diagnostic performance metric in prostate MRI. • With moderate to severe susceptibility artifacts secondary to hip arthroplasty, cancer detection rate decreased to 74% compared to the matched control. • Expanding indications for systematic prostate biopsy may be considered when PI-RADS 1-2 is assigned.

7.
Abdom Radiol (NY) ; 48(6): 2148-2156, 2023 06.
Artículo en Inglés | MEDLINE | ID: mdl-36939909

RESUMEN

PURPOSE: The purpose of this study was to determine the safety and accuracy of aortic and periaortic computed tomography (CT)-guided percutaneous core needle biopsy performed at a single center over 12 years. MATERIALS AND METHODS: A retrospective review was conducted of cases performed between February 2010 and August 2022 in which the biopsied region was in direct contact with the aorta or great vessels including the pericardium and common iliac arteries. Clinical notes were reviewed for any early or delayed complications following the procedure, which if present were graded using the National Institute of Health's Common Terminology Criteria for Adverse Events, version 5.0. Pathology results were compared to subsequent outside biopsy results or follow-up surgical pathology, if available, as well as subsequent clinical decision making and/or clinical course, to determine concordance. Sensitivity, specificity, predictive value, and accuracy (indicative of diagnostic yield) were calculated. RESULTS: 32 core needle biopsies were reviewed from 30 patients (average lesion longest diameter 3.1 cm, range 0.5-10.9 cm; average needle proximity to the vessel endothelium or deep side of the pericardium 1.0 cm, range 0.3-1.8 cm). Complications occurred in 46.9% of cases (15/32), 93.3% (14/15) of which were minor and included small amounts of bleeding or pain. One patient developed a small nonemergent pneumothorax. Of biopsies obtained, 96.9% provided adequate tissue for diagnosis (31/32). When evaluating concordance between pathological and final diagnosis, sensitivity was 94.7% and specificity was 83.3%; positive and negative predictive value were 90.0% and 90.9%, respectively. Accuracy (diagnostic yield) of biopsy was 90.3%. CONCLUSION: CT-guided percutaneous aortic and periaortic core needle biopsies are safe and efficacious procedures with high diagnostic yield.


Asunto(s)
Biopsia Guiada por Imagen , Tomografía Computarizada por Rayos X , Humanos , Biopsia con Aguja Gruesa/efectos adversos , Biopsia con Aguja Gruesa/métodos , Sensibilidad y Especificidad , Biopsia Guiada por Imagen/efectos adversos , Biopsia Guiada por Imagen/métodos , Tomografía Computarizada por Rayos X/métodos , Aorta , Estudios Retrospectivos
8.
J Vasc Interv Radiol ; 34(2): 197-204, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36257582

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of percutaneous magnetic resonance (MR) imaging-guided laser ablation for the treatment of symptomatic soft tissue vascular malformations (VMs) in the face and neck. MATERIALS AND METHODS: An institutional review board-approved retrospective review was undertaken of all consecutive patients who underwent MR imaging-guided and monitored laser ablation for treatment of symptomatic, cervicofacial soft tissue VM. Preablation and postablation MR imaging findings were independently reviewed. Preablation and postablation VM sizes were documented. Preablation T2 signal characteristics and enhancement patterns as well as postablation change in both signal and enhancement were semiquantitatively assessed. Changes in VM size were compared using a paired t test. RESULTS: Thirteen patients (women, 9; age, 14.5-69.5 years) with 13 VMs were treated for moderate-to-severe pain (n = 4), swelling/mass effect (n = 8), or predominantly cosmesis (n = 1) with 22 total ablation sessions. The baseline maximum VM diameter was 5.7 cm ± 4.2. At baseline, all VMs (100%) demonstrated variable T2-weighted signal hyperintensity and enhancement. For painful VM, the baseline pain score was 8 ± 1. Clinical follow-up was available for 10 patients. Of patients with available follow-up, 3 (100%) treated for moderate-to-severe pain and 7 (100%) treated for swelling/mass effect reported subjective complete or partial symptomatic relief. The patient treated predominantly for cosmetic reasons was lost to follow-up. Two patients (15.4%) experienced minor adverse events by the Society of Interventional Radiology standards. There were no major adverse events. CONCLUSIONS: MR imaging-guided and monitored percutaneous laser ablation is safe and effective for the treatment of symptomatic, cervicofacial VMs.


Asunto(s)
Terapia por Láser , Malformaciones Vasculares , Humanos , Femenino , Adolescente , Adulto Joven , Adulto , Persona de Mediana Edad , Anciano , Resultado del Tratamiento , Imagen por Resonancia Magnética , Terapia por Láser/efectos adversos , Terapia por Láser/métodos , Dolor , Malformaciones Vasculares/diagnóstico por imagen , Malformaciones Vasculares/cirugía , Estudios Retrospectivos
9.
Clin Endocrinol (Oxf) ; 98(2): 177-189, 2023 02.
Artículo en Inglés | MEDLINE | ID: mdl-36263687

RESUMEN

OBJECTIVE: The objective of this study was to evaluate the role of adrenal venous sampling (AVS) in guiding the management of patients with corticotropin (ACTH)-independent glucocorticoid secretory autonomy and bilateral adrenal masses. DESIGN AND PATIENTS: A cohort with 25 patients underwent AVS and surgical management. MEASUREMENTS: Cortisol was measured from the adrenal veins (AVs) and inferior vena cava (IVC). AV/IVC cortisol ratio and cortisol lateralization ratio (CLR) (dominant AV cortisol concentration divided by the nondominant AV cortisol concentration) were calculated. Posthoc receiver-operating characteristic curves were generated to determine the specificity of revised AV/IVC cortisol ratio and CLR in differentiating unilateral from bilateral disease. RESULTS: Patients underwent unilateral (n = 21) or bilateral (n = 4) adrenalectomy. The mean AV/IVC cortisol ratio for unilateral adrenalectomy was 12.1 ± 9.6 (dominant) and 4.7 ± 3.8 (contralateral) with a mean CLR of 3.6 ± 3.5. The mean AV/IVC cortisol ratio for bilateral adrenalectomy was 7.5 ± 2.1, with a mean CLR of 1.1 ± 0.6. At a mean follow-up of 22 months, one patient who underwent unilateral adrenalectomy for the predicted bilateral disease developed recurrent mild autonomous cortisol secretion. Posthoc analyses demonstrated a specificity of 95%-100% for unilateral disease with AV/IVC cortisol ratio >9 for one side, <2.0 for the opposite side and a CLR > 2.3. The specificity was 80%-90% for bilateral disease with AV/IVC cortisol ratio >5.1 bilaterally and a CLR < 1.1. CONCLUSIONS: Among patients with bilateral adrenal masses and ACTH-independent autonomous cortisol secretion, AVS can distinguish between unilateral and bilateral disease with high specificity and may guide surgical management.


Asunto(s)
Enfermedades de las Glándulas Suprarrenales , Hiperaldosteronismo , Humanos , Hidrocortisona , Glándulas Suprarrenales/irrigación sanguínea , Adrenalectomía , Hormona Adrenocorticotrópica , Hiperaldosteronismo/cirugía , Estudios Retrospectivos , Aldosterona
10.
PLoS One ; 17(5): e0268829, 2022.
Artículo en Inglés | MEDLINE | ID: mdl-35604891

RESUMEN

PURPOSE: To compare the inter-observer variability of apparent diffusion coefficient (ADC) values of prostate lesions measured by 2D-region of interest (ROI) with and without specific measurement instruction. METHODS: Forty lesions in 40 patients who underwent prostate MR followed by targeted prostate biopsy were evaluated. A multi-reader study (10 readers) was performed to assess the agreement of ADC values between 2D-ROI without specific instruction and 2D-ROI with specific instruction to place a 9-pixel size 2D-ROI covering the lowest ADC area. The computer script generated multiple overlapping 9-pixel 2D-ROIs within a 3D-ROI encompassing the entire lesion placed by a single reader. The lowest mean ADC values from each 2D-small-ROI were used as reference values. Inter-observer agreement was assessed using the Bland-Altman plot. Intraclass correlation coefficient (ICC) was assessed between ADC values measured by 10 readers and the computer-calculated reference values. RESULTS: Ten lesions were benign, 6 were Gleason score 6 prostate carcinoma (PCa), and 24 were clinically significant PCa. The mean±SD ADC reference value by 9-pixel-ROI was 733 ± 186 (10-6 mm2/s). The 95% limits of agreement of ADC values among readers were better with specific instruction (±112) than those without (±205). ICC between reader-measured ADC values and computer-calculated reference values ranged from 0.736-0.949 with specific instruction and 0.349-0.919 without specific instruction. CONCLUSION: Interobserver agreement of ADC values can be improved by indicating a measurement method (use of a specific ROI size covering the lowest ADC area).


Asunto(s)
Imagen de Difusión por Resonancia Magnética , Próstata , Imagen de Difusión por Resonancia Magnética/métodos , Humanos , Imagen por Resonancia Magnética , Masculino , Variaciones Dependientes del Observador , Próstata/diagnóstico por imagen , Reproducibilidad de los Resultados , Estudios Retrospectivos
11.
Ann Diagn Pathol ; 54: 151796, 2021 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-34311301

RESUMEN

A 34-year-old male presented with a swelling on the volar surface of the third digit of his right hand. This swelling was associated with pain and erythema. Ultrasound-guided needle biopsy was performed. Cytologic and histologic preparations together confirmed the diagnosis of a rarely encountered mixed epithelial and mesenchymal proliferation, an eccrine angiomatous hamartoma. To our knowledge, this case is the first to illustrate the cytomorphologic features of this rare lesion.


Asunto(s)
Hamartoma/patología , Hemangioma/patología , Enfermedades de las Glándulas Sudoríparas/patología , Adulto , Citodiagnóstico/métodos , Técnicas Citológicas , Hamartoma/diagnóstico , Hemangioma/diagnóstico , Humanos , Masculino , Enfermedades de las Glándulas Sudoríparas/diagnóstico
12.
J Vasc Interv Radiol ; 32(10): 1417-1424, 2021 10.
Artículo en Inglés | MEDLINE | ID: mdl-34332090

RESUMEN

PURPOSE: To evaluate the safety and effectiveness of percutaneous magnetic resonance (MR) imaging-guided laser ablation and cryoablation for the treatment of symptomatic soft tissue vascular anomalies (VAs) of the trunk and extremities. MATERIALS AND METHODS: An institutional review board-approved retrospective review was undertaken of all pediatric and adult patients who underwent MR imaging-guided and monitored laser ablation and/or cryoablation for the treatment of symptomatic peripheral soft tissue VA. Preablation and postablation MR imaging was independently reviewed. Pain scores on the visual analog scale (0 to 10) and self-reported subjective symptomatic improvement were assessed. Change in VA size and pain scores were compared using a paired t test. RESULTS: Thirty patients (24 females; age, 10-75 years) with 34 VAs were treated for moderate to severe pain (n = 27) or swelling/mass effect (n = 3) with 60 total ablation sessions. The baseline maximum VA diameter was 9.5 cm ± 8.6. At baseline, all VAs (100%) demonstrated variable T2-weighted signal hyperintensity and enhancement. The baseline pain score was 6.4 ± 1.6. Clinical follow-up was available for 23 patients. At a mean follow-up time of 12.2 months ± 10.1, 19 of 20 (95%) patients treated for pain and 2 of 3 (67%) patients treated for swelling/mass effect reported partial or complete symptomatic relief. There was a significant decrease in the postablation pain scores (-5.7 ± 1.0, P < .001) and maximum VA size (-2.3 cm ± 2.7, P = .004), with >50% reduction in VA T2 signal (59%) and enhancement (73%). Nine of 30 (30%) patients experienced minor complications. CONCLUSIONS: MR imaging-guided and monitored percutaneous laser ablation and cryoablation appear to be safe and effective for the treatment of symptomatic peripheral soft tissue VAs.


Asunto(s)
Criocirugía , Terapia por Láser , Adolescente , Adulto , Anciano , Niño , Criocirugía/efectos adversos , Femenino , Humanos , Imagen por Resonancia Magnética , Persona de Mediana Edad , Estudios Retrospectivos , Resultado del Tratamiento , Adulto Joven
13.
Abdom Radiol (NY) ; 46(12): 5466-5470, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-34086092

RESUMEN

The Society of Abdominal Radiology (SAR) has grown rapidly in the last decade and with growth comes opportunity. The purpose of this article is to highlight the many potential ways in which early career radiologists (those within the first 7 years of their career) can become involved with the SAR, both at the annual meeting and throughout the year. At the annual meeting, there are opportunities for presentation of scientific sessions as well as submission of clinically oriented workshops. Workshops are a great way to develop presentation skills and highlight subspecialty clinical expertise. Disease focus panels (DFPs) and Emerging Technology Committees (ETCs) meet at the annual meeting but continue their work throughout the year, targeting improvements in clinical care and research. Finally, a variety of volunteer staffed committees are essential to the fulfillment of the mission of the SAR, and several of these are targeted at involving early career members, providing opportunities for leadership and exposure to other members of the society.


Asunto(s)
Liderazgo , Radiología , Humanos , Radiólogos , Sociedades Médicas , Tecnología
15.
Abdom Radiol (NY) ; 46(12): 5489-5499, 2021 12.
Artículo en Inglés | MEDLINE | ID: mdl-33999282

RESUMEN

PURPOSE: To initiate a peer learning conference for our abdominal radiology division across multiple geographically separated sites and different time zones, and to determine radiologist preference for peer learning versus traditional score-based peer review. METHODS: We implemented a monthly peer learning videoconference for our abdominal radiology division. Surveys regarding radiologist opinion regarding traditional peer review and the new peer learning conferences were conducted before and after 6 months of conferences. RESULTS: Peer learning conferences were well attended across our multiple sites, with an average of 43 participants per conference. Radiologist opinion regarding peer review was poor, with survey radiologists responding positively to only 1 out of 12 process questions. Opinion regarding peer learning was extremely favorable, with radiologists responding positively to 12 out of the same 12 process questions. After 6 months of peer learning conferences, 87.9% of surveyed radiologists wished to continue them in some fashion, and no one preferred to return to score-based peer review alone. CONCLUSION: We successfully implemented a peer learning conference for our abdominal radiology division spread out over multiple geographic sites. Our radiologists strongly preferred peer learning conferences over our traditional peer review system for quality control.


Asunto(s)
Radiología , Humanos , Revisión por Pares , Radiografía Abdominal , Radiólogos , Encuestas y Cuestionarios
16.
J Vasc Interv Radiol ; 32(8): 1227-1230, 2021 Aug.
Artículo en Inglés | MEDLINE | ID: mdl-33961989

RESUMEN

The clinical outcomes of major bleeding events following ultrasound-guided native and allograft parenchymal renal biopsy were evaluated. Forty-eight bleeding complications after biopsy (Society of Interventional Radiology adverse event grade ≥ 2) from 2002 to 2018 were identified. The primary outcome assessed was renal function. The clinical outcomes and interventions performed, including blood transfusion, angiography with or without embolization, nephrostomy tube placement, surgery, nephrectomy, hospitalization, intensive care unit admission, dialysis, and survival, were noted. Renal function may be moderately diminished in the short-term periprocedural setting. None of the patients studied died or required nephrectomy or the initiation of dialysis as a result of a major bleeding complication after the renal biopsy.


Asunto(s)
Hemorragia , Riñón , Hemorragia/etiología , Humanos , Biopsia Guiada por Imagen/efectos adversos , Riñón/diagnóstico por imagen , Riñón/fisiología , Estudios Retrospectivos , Ultrasonografía , Ultrasonografía Intervencional
17.
Radiol Case Rep ; 16(5): 1072-1074, 2021 May.
Artículo en Inglés | MEDLINE | ID: mdl-33717385

RESUMEN

Acute appendiceal diverticulitis is a difficult prospective diagnosis due to both its rarity and clinical overlap with other ileocecal diseases, such as acute appendicitis. Few preoperative radiological images of acute appendiceal diverticulitis have been presented in the literature. We report a case of acute appendiceal diverticulitis initially diagnosed with outpatient ultrasound and confirmed with contrast-enhanced computed tomography in an 85-year-old male who presented with right lower quadrant pain. Appendiceal diverticulitis is an often overlooked diagnosis, and given its association with appendiceal neoplasms and relatively high rate of perforation, it is important to consider this entity in patients with right lower quadrant pain in order to ensure that they are managed appropriately. The addition of high quality ultrasound and computed tomography (CT) images to the literature may heighten awareness of this rare condition and facilitate accurate preoperative diagnosis and management in these patients.

18.
J Vasc Interv Radiol ; 32(5): 745-751, 2021 05.
Artículo en Inglés | MEDLINE | ID: mdl-33608193

RESUMEN

PURPOSE: To retrospectively evaluate the incidence of carcinoid crisis, other complications, and physiologic disturbances during percutaneous image-guided core needle biopsy of neuroendocrine tumors (NETs) in the lung and the liver. MATERIALS AND METHODS: Between January 2010 and January 2020, 106 computed tomography (CT) or ultrasound (US)-guided core needle biopsies of lung and liver NETs were performed in 95 consecutive adult patients. The mean age was 64 ± 13 years, and 48% were female. The small bowel was the most common primary site (33%, 31/95), and 32 (34%) patients had pre-existing symptoms of carcinoid syndrome. The mean tumor size was 3.2 ± 2.6 cm, and mean number of passes was 3.4 ± 1.6. A 17/18-gauge needle was used in 91% (96/106) of the biopsies. Thirteen (12%) patients received either outpatient or prophylactic octreotide. RESULTS: No patients experienced carcinoid crisis or needed octreotide, inotropes, vasopressors, or resuscitation. A single biopsy procedure (0.9%, 1/106) was complicated by bleeding that required angiographic hepatic artery embolization. Changes in pre-biopsy- versus post-biopsy systolic blood pressure and heart rate were -1.6 mm Hg (P = .390) and 0.6 beat/min (P = .431), respectively. Tumor functional status, overall tumor burden, and the elevation of neuroendocrine markers were not associated with intraprocedural physiologic disturbances. There were 4 minor complications (0.4%, 4/106) associated with the biopsy procedure that were not attributed to hormone excretion from tumor manipulation. CONCLUSIONS: Percutaneous image-guided core biopsy of NETs is safe, with low complication rate and no definite carcinoid crisis in the current cohort.


Asunto(s)
Biopsia con Aguja Gruesa/efectos adversos , Biopsia Guiada por Imagen/efectos adversos , Neoplasias Hepáticas/patología , Neoplasias Pulmonares/patología , Síndrome Carcinoide Maligno/epidemiología , Tumores Neuroendocrinos/patología , Radiografía Intervencional/efectos adversos , Ultrasonografía Intervencional/efectos adversos , Anciano , Femenino , Humanos , Incidencia , Neoplasias Hepáticas/diagnóstico por imagen , Neoplasias Pulmonares/diagnóstico por imagen , Masculino , Síndrome Carcinoide Maligno/diagnóstico , Persona de Mediana Edad , Tumores Neuroendocrinos/diagnóstico por imagen , Estudios Retrospectivos , Medición de Riesgo , Factores de Riesgo
19.
J Thorac Dis ; 12(11): 6978-6991, 2020 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-33282403

RESUMEN

Ongoing technologic and therapeutic advancements in medicine are now testing the limits of conventional anatomic imaging techniques. The ability to image physiology, rather than simply anatomy, is critical in the management of multiple disease processes, especially in oncology. Nuclear medicine has assumed a leading role in detecting, diagnosing, staging and assessing treatment response of various pathologic entities, and appears well positioned to do so into the future. When combined with computed tomography (CT) or magnetic resonance imaging (MRI), positron emission tomography (PET) has become the sine quo non technique of evaluating most solid tumors especially in the thorax. PET/CT serves as a key imaging modality in the initial evaluation of pulmonary nodules, often obviating the need for more invasive testing. PET/CT is essential to staging and restaging in bronchogenic carcinoma and offers key physiologic information with regard to treatment response. A more recent development, PET/MRI, shows promise in several specific lung cancer applications as well. Additional recent advancements in the field have allowed PET to expand beyond imaging with 18F-flurodeoxyglucose (FDG) alone, now with the ability to specifically image certain types of cell surface receptors. In the thorax this predominantly includes 68Ga-DOTATATE which targets the somatostatin receptors abundantly expressed in neuroendocrine tumors, including bronchial carcinoid. This receptor targeted imaging technique permits targeting these tumors with therapeutic analogues such as 177Lu labeled DOTATATE. Overall, the proper utilization of PET in the thorax has the ability to directly impact and improve patient care.

20.
Endosc Int Open ; 8(10): E1487-E1494, 2020 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-33043118

RESUMEN

Background and study aims Management of malignant gastrointestinal obstruction (MGIO) is more challenging in the presence of peritoneal carcinomatosis (PC). Outcomes data to guide the management of MGIO with PC are lacking. We aimed to compare the clinical outcomes and adverse events between endoscopic and surgical palliation and identify predictors of stent success in patients with MGIO with PC. Patients and methods Consecutive inpatients with MGIO with PC between 2000 and 2018 who underwent palliative surgery or enteral stenting were included. Clinical success was defined as relief of obstructive symptoms. Results Fifty-seven patients with enteral stenting and 40 with palliative surgery were compared. The two groups did not differ in rates of technical success, 30-day mortality, or recurrence. Clinical success from a single intervention (63.2 % versus 95 %), luminal patency duration (27 days vs. 145 days), and survival length (148 days vs. 336 days) favored palliative surgery (all P  < 0.05) but the patients in the surgery group had a trend toward better Eastern Cooperative Oncology Group (ECOG) status. The rate of adverse events (AEs) (10.5 % vs. 50 %), the severity of AEs, and length of hospital stay (4.5 days vs. 9 days) favored enteral stenting ( P  < 0.05). The need for more than one stent was associated with a higher likelihood of stent failure. Conclusions Our study suggests that enteral stenting is safer and associated with a shorter hospital stay than palliative surgery, although unlike other MGIOs, clinical success is lower in MGIO with PC. Identification of the right candidates and potential predictors of clinical success in ECOG-matched large-scale studies is needed to validate these results.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...