RESUMEN

BACKGROUND: Sclerotherapy is a cornerstone of the treatment of chronic venous disease, despite some technical aspects (e.g., sclerosant liquid agent concentration [SLAC] and contact time between sclerosant agent and vein wall [ctSA/VW]) to maximize outcomes remain an unsolved problem and a source of debate. An innovative three-balloon catheter has been developed to allow sclerotherapy in empty vein conditions (Empty Vein Ablation technique, EVA), revolutionizing the definition of SLAC and ctSA/VW. Aim of this experimental study is to analyze EVA effects on intima and media vessel tunicae using different SLAC and ctSA/VW in an in-vivo animal model. METHODS: Two adult sheep were treated by EVA using jugular and common iliac vein axes (eight vein segments). Different SLAC (polidocanol 0.5% or 1%) and different ctSA/VW (3 or 5 minutes) were combined for testing residual circumferential intima percentage and media thickness after EVA. RESULTS: Intact circumferential residual intima after the treatment was 21.3±4.9%, 18.2±7.4%, 15.7±2.4% and 8.9±2.0% using 0.5% (3 min), 0.5% (5 min), 1% (3 min) and 1% (5 min), respectively (R2=0.945; control sample: 97.6%). Media thickness after the treatment was 121.6±35.3 µm, 110.9±7.8 µm, 96.1±30.4 µm and 79.1±34.1 µm using 0.5% (3 min), 0.5% (5 min), 1% (3 min) and 1% (5 min), respectively (R2=0.990; control sample 125.7 µm). No significant modifications were detected analyzing the adventitia in all samples. CONCLUSIONS: EVA proved to be effective in venous wall destruction even with a very low SLAC and ctSA/VW (0.5% in 3 minutes), in quite large caliber veins. Direct comparisons with foam/liquid sclerotherapy should be done to confirm therapeutic effectiveness of these results, despite EVA has provided a maximized and controlled SA/VW contact time and ratio.


Asunto(s)
Polidocanol , Soluciones Esclerosantes , Escleroterapia , Túnica Íntima , Túnica Media , Animales , Túnica Íntima/patología , Túnica Íntima/cirugía , Túnica Media/patología , Ovinos , Vena Ilíaca/cirugía , Venas Yugulares/cirugía , Factores de Tiempo , Técnicas de Ablación , Modelos Animales , Modelos Animales de Enfermedad
2.
Int Angiol ; 42(5): 420-426, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37377397

RESUMEN

BACKGROUND: Sclerotherapy is among the mainstays of chronic venous disease treatment, yet its occlusion rate remains suboptimal compared to thermal tumescent techniques. An innovative three-balloons catheter has been developed to allow sclerotherapy in empty vein conditions (empty vein ablation technique, EVA). Aim of this investigation was to describe the EVA technical aspects and related ex-vivo effects on vein wall. METHODS: Two samples from jugular veins of an adult sheep were treated by EVA or foam sclerotherapy (FS, Tessari method). Primary outcome was the percentage of circumferential intima treated by EVA or FS; secondary outcomes were intima and media thickness modifications after treatment. RESULTS: Intact circumferential residual intima were 6.07±2.94% and 16.55±0.70% after EVA and FS, respectively (P=0.020). Despite the average intima and media thickness did not differ between treatments, EVA demonstrated a homogenous damage throughout the vein segment, while FS effect was less destructive distally to the injection site, because moving away from the injection site and floating, it has a less contact with internal surface of the vein. CONCLUSIONS: EVA seems to overcome chemical ablation limits as flushing effect and the increases vein wall/sclerosant agent contact effect compared to FS. Ex-vivo encouraging results need in-vivo validation to evaluate other points like deactivation of sclerosing agent by blood protein and the contact time control between SA and the vein wall. If we have further confirmations in vivo we might think we have a potential higher occlusion rate compared to FS, paving the way for future clinical trials.


Asunto(s)
Técnicas de Ablación , Várices , Insuficiencia Venosa , Humanos , Animales , Ovinos , Várices/cirugía , Venas , Soluciones Esclerosantes , Escleroterapia/efectos adversos , Escleroterapia/métodos , Vena Safena/diagnóstico por imagen , Vena Safena/cirugía , Resultado del Tratamiento , Insuficiencia Venosa/cirugía
3.
J Cardiovasc Electrophysiol ; 33(5): 874-882, 2022 05.
Artículo en Inglés | MEDLINE | ID: mdl-35262242

RESUMEN

INTRODUCTION: Lesion Index (LSI) has been developed to predict lesion efficacy during radiofrequency (RF) catheter ablation. However, its value in predicting lesions size has still to be established. The aim of our study was to assess the lesions size reproducibility for prespecified values of LSI reached during RF delivery in an in vivo beating heart. METHODS: Ablation lesions were created with different values of LSI in seven domestic pigs by means of a contact force-sensing catheter (TactiCathTM , Abbott). Lesions were identified during RF delivery by means of a three-dimensional mapping system (EnSiteTM Precision, Abbott) and measured after heart explantation. Histology was carried out after gross examination on the first three lesions to confirm the accuracy of the macroscopic evaluation. RESULTS: A total of 64 myocardial lesions were created. Thirty-nine lesions were excluded from the analysis for the following reasons: histological confirmation of macroscopic lesion measurement (n = 3), transmurality (n = 24), unfavorable anatomic position (n = 10), not macroscopically identifiable (n = 2). In a final set of 25 nontransmural lesions, injury width and depth were, respectively, 4.6 ± 0.6 and 2.6 ± 0.8 mm for LSI = 4, 7.3 ± 0.8 and 4.7 ± 0.6 mm for LSI = 5, and 8.6 ± 1.2 and 7.2 ± 1.1 mm for LSI = 6. A strong linear correlation was observed between LSI and lesion width (r = .87, p < .00001) and depth (r = .89, p < .00001). Multiple linear regression analysis identified LSI as the only ablation parameter that significantly predicted lesion width (p < .001) and depth (p < .001). CONCLUSION: In our in vivo study, LSI proved highly predictive of lesion size and depth.


Asunto(s)
Ablación por Catéter , Animales , Ablación por Catéter/efectos adversos , Ablación por Catéter/métodos , Catéteres , Corazón , Humanos , Reproducibilidad de los Resultados , Sus scrofa , Porcinos
4.
Materials (Basel) ; 15(3)2022 Jan 28.
Artículo en Inglés | MEDLINE | ID: mdl-35160976

RESUMEN

Different xenogeneic inorganic bone substitutes are currently used as bone grafting materials in oral and maxillo-facial surgery. The aim of the present study was to determine the physicochemical properties and the in vivo performance of an anorganic equine bone (AEB) substitute. AEB is manufactured by applying a process involving heating at >300 °C with the aim of removing all the antigens and the organic components. AEB was structurally characterized by scanning electron microscopy (SEM), X-ray diffraction (XRD), X-ray fluorescence (XRF), and Fourier-transformed infrared (FT-IR) spectroscopy and compared to the anorganic bovine bone (ABB). In order to provide a preliminary evaluation of the in vivo performance of AEB, 18 bone defects were prepared and grafted with AEB (nine sites), or ABB (nine sites) used as a control, in nine Yucatan Minipigs. De novo bone formation, residual bone substitute, as well as local inflammatory and tissue effects were histologically evaluated at 30 and 90 days after implantation. The structural characterization showed that the surface morphology, particle size, chemical composition, and crystalline structure of AEB were similar to cancellous human bone. The histological examination of AEB showed a comparable pattern of newly formed bone and residual biomaterial to that of ABB. Overall, the structural data and pre-clinical evidence reported in the present study suggests that AEB can be effectively used as bone grafting material in oral surgery procedures.

5.
Materials (Basel) ; 14(9)2021 Apr 27.
Artículo en Inglés | MEDLINE | ID: mdl-33925604

RESUMEN

Despite high rates of osseointegration in healthy patients, complex cases present an increased risk of osseointegration failure when treated with dental implants. Furthermore, if immediate loading of the implants is used, maximizing the response of the host organism would be desirable. Anabolic steroids, such as Nandrolone Decanoate (ND), are reported to have beneficial clinical effects on various bone issues such as osteoporosis and bone fractures. However, their beneficial effects in promoting osseointegration in dental implant placement have not been documented. The study aimed to examine histological changes induced by ND in experimental dental implants in rabbit models. Two dental implants were placed in the tibias of 24 adult rabbits. Rabbits were allocated to one of two groups: control group or test group. Rabbits in the latter group were given nandrolone decanoate (15 mg/kg, immediately after implant placement and after 1 week). Micro-radiographic and histological analyses were assessed to characterize the morphological changes promoted by the nandrolone decanoate use. Total bone volume and fluorescence were significantly higher in the control group after 2 weeks. Such a difference between the two groups might indicate that, initially, nandrolone lengthens the non-specific healing period characteristic of all bone surgeries. However, after the beginning of the reparative processes, the quantity of newly formed bone appears to be significantly higher, indicating a positive stimulation of the androgen molecule on bone metabolism. Based on micro-radiology and fluorescence microscopy, nandrolone decanoate influenced bone regeneration in the implant site. The anabolic steroid nandrolone decanoate affects the healing processes of the peri-implant bone and therefore has the potential to improve the outcomes of implant treatment in medically complex patients.

6.
BMC Surg ; 20(1): 215, 2020 Sep 25.
Artículo en Inglés | MEDLINE | ID: mdl-32977788

RESUMEN

BACKGROUND: Several topical hemostats are available to help control surgical bleeding. Cutanplast is a highly absorbent and porous gelatin product that is available in Fast sponge and powder forms. This study investigated the hemostatic efficacy of Cutanplast Standard and Fast gelatin sponge and powder and Emosist oxidized regenerated cellulose (ORC) gauze in porcine liver and spleen surgical bleeding models. METHODS: Cutanplast Standard and Fast gelatin sponge and Emosist ORC gauze were tested in liver abrasion/incision, liver puncture and spleen incision/puncture injuries, and Cutanplast Standard and Fast gelatin powder products were tested in liver abrasion/incision injuries. There were 13 liver injury (five abrasion, five incision and three puncture) and six spleen injury (three puncture and three incision sites) sites per animal. RESULTS: Rapid hemostasis (≤ 2-5 min) was achieved in the liver abrasion and incision models with all Cutanplast gelatin sponge and powder products and Emosist ORC gauze, except in the liver incision model, time to hemostasis was > 5 min with Cutanplast Standard gelatin powder and Emosist ORC gauze. Rapid hemostasis occurred with Cutanplast Fast gelatin sponge and Emosist ORC gauze in the liver puncture and spleen puncture and incision models. In the spleen incision model, Cutanplast Standard gelatin sponge had a time to hemostasis approaching 10 min. CONCLUSION: Cutanplast gelatin sponge and powder products and Emosist ORC gauze may be suitable for surgical applications involving parenchymal organ bleeding, but certain products may perform better than others, including Cutanplast gelatin powder in diffuse mild bleeding (such as liver abrasion), and Cutanplast Fast gelatin sponge and Emosist ORC gauze for splenic bleeding.


Asunto(s)
Pérdida de Sangre Quirúrgica/prevención & control , Hemostasis Quirúrgica , Hígado/cirugía , Bazo/cirugía , Animales , Esponja de Gelatina Absorbible , Hemostáticos , Porcinos
7.
Implant Dent ; 26(3): 357-366, 2017 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-28234707

RESUMEN

BACKGROUND: Many chemical and physical modifications of titanium surfaces were introduced, aiming at improving surface bioactivity, but few comparative evidence exists. OBJECTIVE: To evaluate histologically in minipigs the osseointegration of implants made of commercially pure (CP) titanium or titanium alloy, treated by different roughening procedures. MATERIAL AND METHODS: Three sandblasted acid-etched (SA) surfaces, 2 anodized (AN), and 1 double acid-etched (DAE) were compared. Surface microtopography was characterized with scanning electron microscope; surface element composition was also assessed. One implant per group was inserted in each proximal tibia of 2 minipigs. Three months after healing, block biopsies were taken for histomorphometric analysis. Implant stability quotient (ISQ) was measured at insertion and before harvesting. RESULTS: The highest amount of cortical bone-implant contact was observed around SA implants and showed positive correlation with surface roughness. The greatest increase in ISQ was observed in CP-AN implants. In the medullary region, SA implants showed the best osteogenic response, whereas inflammatory cells were found around DAE and alloy-AN implants. CONCLUSIONS: SA surfaces were more osteogenic than anodized or dual acid-etched ones, although not significantly. Surface roughness affected osseointegration.


Asunto(s)
Interfase Hueso-Implante/fisiología , Implantación Dental Endoósea/métodos , Implantes Dentales , Oseointegración/fisiología , Titanio/química , Grabado Ácido Dental , Animales , Biopsia , Aleaciones Dentales/química , Diseño de Prótesis Dental , Femenino , Implantes Experimentales , Ensayo de Materiales , Microscopía Electrónica de Rastreo , Modelos Animales , Propiedades de Superficie , Porcinos , Tibia/cirugía
8.
EuroIntervention ; 12(7): 918-25, 2016 Sep 18.
Artículo en Inglés | MEDLINE | ID: mdl-27639745

RESUMEN

AIMS: The aim of this study was to evaluate the safety, technical feasibility and performance of a new trans-catheter tricuspid repair system. METHODS AND RESULTS: Thirty-one adult swine underwent implantation of a transcatheter tricuspid remodelling system under general anaesthesia. The steerable transcatheter device was introduced through a 24 Fr femoral sheath into the right femoral vein and delivered to the tricuspid annulus on the beating heart. A fixation element was implanted into the tricuspid annulus. Following implantation, a second delivery system was used to couple the fixation element with a self-expanding nitinol stent. The device was tensioned to reshape the tricuspid valve and increase the coaptation length of the valve leaflets under echo guidance. Finally, the stent was deployed in the inferior vena cava (IVC) to maintain the tension applied. The transcatheter device was successfully implanted in all animals (n=31). Doppler echocardiography prior to sacrifice showed that tricuspid valve function was stable and normal tricuspid leaflet motion was observed. Cinching of the tricuspid annulus resulted in an increase of leaflet coaptation length of 70% (4.5±0.7 mm to 7.78±1.3 mm), an increase in trans-tricuspid peak velocity of 79% (0.38±0.1 m/s to 0.68±0.1 m/s), and a reduction in septolateral tricuspid valve dimension of 30% (35.2±5 mm to 24.8±5 mm). At necropsy, the fixation element was firmly attached to the annulus within a fibrotic tissue, with no coronary lesions observed and no abnormality visible. The stent was fully deployed in the IVC, without displacement or change in the stent shape. CONCLUSIONS: Percutaneous beating heart remodelling of the tricuspid annulus with a cinching device is safe and feasible.


Asunto(s)
Anuloplastia de la Válvula Cardíaca/instrumentación , Procedimientos Endovasculares/instrumentación , Válvula Tricúspide/cirugía , Animales , Anuloplastia de la Válvula Cardíaca/métodos , Estudios de Factibilidad , Porcinos
9.
EuroIntervention ; 12(11): e1428-e1434, 2016 Dec 10.
Artículo en Inglés | MEDLINE | ID: mdl-26573974

RESUMEN

AIMS: The aim of the study was to report preclinical safety and feasibility of a new transcatheter direct mitral annuloplasty intervention in an acute animal model. METHODS AND RESULTS: Twenty healthy pigs underwent Cardioband (Valtech Cardio, Or Yehuda, Israel) transcatheter implantation under intracardiac echocardiographic and fluoroscopic guidance. Through a neo inferior vena cava approach, transseptal access was arranged. The device was delivered into the left atrium using a multi-steerable catheter and fixed to the mitral annulus with multiple helix anchors. Following device cinching, reduction of annular size was evaluated. In all animals the device could be successfully implanted and displayed 100% function, with the average procedure duration and fluoroscopy times being 78±23 minutes and 27±9 minutes, respectively. In total, 246 anchors (average 12.3 per device) were delivered and optimal anchor placement was achieved in 95.1%, while inadequate anchor position (4%) and injury of the coronary sinus or atrium (0.8%) occurred in the rest. Following maximal cinching, diastolic transmitral flow velocity and coaptation lengths were markedly increased (p<0.001), whereas septolateral and intercommissural distances were significantly decreased (p<0.001), when compared to pre-contraction baseline, demonstrating efficient annular reduction by the device. CONCLUSIONS: Transcatheter direct annuloplasty with a surgical-like adjustable device is feasible in the porcine animal model. The humanised porcine model has been instrumental in demonstrating feasibility and in establishing the procedural steps.


Asunto(s)
Atrios Cardíacos/cirugía , Implantación de Prótesis de Válvulas Cardíacas , Anuloplastia de la Válvula Mitral , Insuficiencia de la Válvula Mitral/cirugía , Válvula Mitral/cirugía , Animales , Cateterismo Cardíaco , Seno Coronario/cirugía , Femenino , Implantación de Prótesis de Válvulas Cardíacas/métodos , Válvula Mitral/fisiopatología , Anuloplastia de la Válvula Mitral/métodos , Insuficiencia de la Válvula Mitral/fisiopatología , Modelos Animales , Porcinos
10.
J Cardiovasc Transl Res ; 8(5): 319-27, 2015 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-25968135

RESUMEN

Heart valve disease is a frequently encountered pathology, related to high morbidity and mortality rates. Animal models are interesting to investigate the causality but also underlying mechanisms and potential treatments of human heart valve diseases. Strongly believing that both in vivo and ex vivo models are fundamental to support research and development of new technologies, we here report some examples of heart valve disease models, which in our experience have been actively used to support the development of new valve therapies.


Asunto(s)
Enfermedades de las Válvulas Cardíacas/terapia , Animales , Cateterismo Cardíaco , Válvulas Cardíacas/trasplante , Modelos Biológicos , Modelos Cardiovasculares , Ovinos , Porcinos , Ingeniería de Tejidos
11.
EuroIntervention ; 11(1): 92-5, 2015 May.
Artículo en Inglés | MEDLINE | ID: mdl-25671425

RESUMEN

AIMS: Preclinical studies and translational animal models are fundamental for the development of new clinical interventions. Compared to human anatomy, pigs present a more anterior heart position in the chest which may jeopardise the imaging and testing of devices designed to be delivered to the human mitral valve. To imitate human anatomy, we developed a novel model to "humanise" a pig heart. METHODS AND RESULTS: The creation of a neo inferior vena cava with a Dacron tube grafted to the right atrium was tested for transseptal delivery of an experimental mitral annuloplasty device in 35 animals. In 15 animals with native anatomy a conventional right transfemoral access was used. Imaging guidance was achieved with intracardiac or epicardial echocardiography. In all transfemoral approaches (n=15), the delivery of the device was unsuccessful and the handling was dissimilar to a human implant. In all neo-cava approaches (n=35), the handling and manoeuvring were as expected in humans, the targets were reached as intended and all procedures but one were successful. CONCLUSIONS: A translational "humanised" animal model with the creation of a neo cava eliminates the differences between pig and human anatomy and is suitable for testing human grade devices.


Asunto(s)
Implantación de Prótesis Vascular/instrumentación , Prótesis Vascular , Cateterismo Cardíaco/métodos , Implantación de Prótesis de Válvulas Cardíacas/métodos , Anuloplastia de la Válvula Mitral/métodos , Estructuras Creadas Quirúrgicamente , Vena Cava Inferior/cirugía , Animales , Cateterismo Periférico , Femenino , Arteria Femoral , Atrios Cardíacos/cirugía , Humanos , Modelos Animales , Tereftalatos Polietilenos , Diseño de Prótesis , Punciones , Sus scrofa , Ultrasonografía Intervencional
12.
J Hematol Oncol ; 7: 46, 2014 Oct 05.
Artículo en Inglés | MEDLINE | ID: mdl-25284315

RESUMEN

BACKGROUND: Exportin 1 (XPO1), also called chromosome region maintenance 1 (CRM1), is the sole exportin mediating transport of many multiple tumor suppressor proteins out of the nucleus. AIM AND METHODS: To verify the hypothesis that XPO1 inhibition affects prostate cancer (PCa) metastatic potential, orally available, potent and selective, SINE compounds, Selinexor (KPT- 330) and KPT-251, were tested in preclinical models known to generate bone lesions and systemic tumor spread. RESULTS: In vitro, Selinexor reduced both secretion of proteases and ability to migrate and invade of PCa cells. SINEs impaired secretion of pro-angiogenic and pro-osteolytic cytokines and reduced osteoclastogenesis in RAW264.7 cells. In the intra-prostatic growth model, Selinexor reduced DU145 tumor growth by 41% and 61% at the doses of 4 mg/Kg qd/5 days and 10 mg/Kg q2dx3 weeks, respectively, as well as the incidence of macroscopic visceral metastases. In a systemic metastasis model, following intracardiac injection of PCb2 cells, 80% (8/10) of controls, 10% (1/10) Selinexor- and 20% (2/10) KPT-251-treated animals developed radiographic evidence of lytic bone lesions. Similarly, after intra-tibial injection, the lytic areas were higher in controls than in Selinexor and KPT-251 groups. Analogously, the serum levels of osteoclast markers (mTRAP and type I collagen fragment, CTX), were significantly higher in controls than in Selinexor- and KPT-251-treated animals. Importantly, overall survival and disease-free survival were significantly higher in Selinexor- and KPT-251-treated animals when compared to controls. CONCLUSIONS: Selective blockade of XPO1-dependent nuclear export represents a completely novel approach for the treatment of advanced and metastatic PCa.


Asunto(s)
Transporte Activo de Núcleo Celular/efectos de los fármacos , Antineoplásicos/farmacología , Carioferinas/metabolismo , Metástasis de la Neoplasia/patología , Neoplasias de la Próstata/patología , Receptores Citoplasmáticos y Nucleares/metabolismo , Animales , Western Blotting , Línea Celular Tumoral , Movimiento Celular , Humanos , Hidrazinas/farmacología , Masculino , Ratones SCID , Osteoblastos/efectos de los fármacos , Neoplasias de la Próstata/metabolismo , Triazoles/farmacología , Ensayos Antitumor por Modelo de Xenoinjerto , Proteína Exportina 1
13.
J Cell Mol Med ; 18(10): 1964-74, 2014 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-25216283

RESUMEN

The meniscus plays important roles in knee function and mechanics and is characterized by a heterogeneous matrix composition. The changes in meniscus vascularization observed during growth suggest that the tissue-specific composition may be the result of a maturation process. This study has the aim to characterize the structural and biochemical variations that occur in the swine meniscus with age. To this purpose, menisci were collected from young and adult pigs and divided into different zones. In study 1, both lateral and medial menisci were divided into the anterior horn, the body and the posterior horn for the evaluation of glycosaminoglycans (GAGs), collagen 1 and 2 content. In study 2, the menisci were sectioned into the inner, the intermediate and the outer zones to determine the variations in the cell phenotype along with the inner-outer direction, through gene expression analysis. According to the results, the swine meniscus is characterized by an increasing enrichment in the cartilaginous component with age, with an increasing deposition in the anterior horn (GAGs and collagen 2; P < 0.01 both); moreover, this cartilaginous matrix strongly increases in the inner avascular and intermediate zone, as a consequence of a specific differentiation of meniscal cells towards a cartilaginous phenotype (collagen 2, P < 0.01). The obtained data add new information on the changes that accompany meniscus maturation, suggesting a specific response of meniscal cells to the regional mechanical stimuli in the knee joint.


Asunto(s)
Cartílago/metabolismo , Perfilación de la Expresión Génica , Glicosaminoglicanos/metabolismo , Meniscos Tibiales/citología , Meniscos Tibiales/metabolismo , Animales , Western Blotting , Cartílago/citología , Diferenciación Celular , Células Cultivadas , Colágeno/genética , Colágeno/metabolismo , Femenino , Técnica del Anticuerpo Fluorescente , Articulación de la Rodilla/anatomía & histología , Articulación de la Rodilla/citología , Articulación de la Rodilla/metabolismo , Meniscos Tibiales/anatomía & histología , Fenotipo , ARN Mensajero/genética , Reacción en Cadena en Tiempo Real de la Polimerasa , Reacción en Cadena de la Polimerasa de Transcriptasa Inversa , Porcinos
14.
Stem Cell Res Ther ; 4(6): 148, 2013.
Artículo en Inglés | MEDLINE | ID: mdl-24330736

RESUMEN

INTRODUCTION: Adipose-derived stem cells (ASCs) are progenitor cells used in bone tissue engineering and regenerative medicine. Despite subcutaneous adipose tissue being more abundant, the buccal fat pad (BFP) is easily accessible for dentists and maxillofacial surgeons. For this reason, considering the need for preclinical study and the swine as an optimal animal model in tissue engineering applications, we compared the features of porcine ASCs (pASCs) from both tissue-harvesting sites. METHODS: ASCs were isolated from interscapular subcutaneous adipose tissue (ScI) and buccal fat pads of six swine. Cells were characterized for their stemness and multipotent features. Moreover, their osteogenic ability when cultured on titanium disks and silicon carbide-plasma-enhanced chemical vapor-deposition fragments, and their growth in the presence of autologous and heterologous serum were also assessed. RESULTS: Independent of the harvesting site, no differences in proliferation, viability, and clonogenicity were observed among all the pASC populations. Furthermore, when induced toward osteogenic differentiation, both ScI- and BFP-pASCs showed an increase of collagen and calcified extracellular matrix (ECM) production, alkaline phosphatase activity, and osteonectin expression, indicating their ability to differentiate toward osteoblast-like cells. In addition, they differentiated toward adipocyte-like cells, and chondrogenic induced pASCs were able to increase glycosaminoglycans (GAGs) production over time. When cells were osteoinduced on synthetic biomaterials, they significantly increased the amount of calcified ECM compared with control cells; moreover, titanium showed the osteoinductive effect on pASCs, also without chemical stimuli. Finally, these cells grew nicely in 10% FBS, and no benefits were produced by substitution with swine serum. CONCLUSIONS: Swine buccal fat pad contains progenitor cells with mesenchymal features, and they also osteo-differentiate nicely in association with synthetic supports. We suggest that porcine BFP-ASCs may be applied in preclinical studies of periodontal and bone-defect regeneration.


Asunto(s)
Tejido Adiposo/citología , Células Madre/citología , Grasa Subcutánea/citología , Fosfatasa Alcalina/metabolismo , Animales , Materiales Biocompatibles/química , Diferenciación Celular , Células Cultivadas , Condrogénesis , Colágeno/metabolismo , Evaluación Preclínica de Medicamentos , Matriz Extracelular/metabolismo , Glicosaminoglicanos/metabolismo , Enfermedades de la Boca/cirugía , Osteogénesis , Osteonectina/metabolismo , Trasplante de Células Madre , Células Madre/metabolismo , Porcinos , Ingeniería de Tejidos
15.
Int J Oral Maxillofac Implants ; 27(1): 95-101, 2012.
Artículo en Inglés | MEDLINE | ID: mdl-22299085

RESUMEN

PURPOSE: The purpose of this study was to evaluate the healing of an injectable mixture of nanoparticles of magnesium-enriched hydroxyapatite (mHA) in peri-implant defects. MATERIALS AND METHODS: Thirty-two dental implants were placed in 16 tibiae of eight female Large White pigs. In each animal, four implant beds (two sites each tibia) with medial three-wall intrabony defects were prepared. Via random selection, one bone defect in each tibia was filled with injectable mHA putty (n = 16, test group), whereas the other defect was not filled (n = 16, control group). Two animals were sacrificed after 2 weeks, two after 4 weeks, two after 6 weeks, and two after 8 weeks. In all, 32 block section samples were obtained for histologic and histomorphometric analyses. RESULTS: The test group exhibited statistically significantly higher values for bone-to-implant contact (BIC) and lower amounts of connective tissue (CT) over time. The test group showed a remarkable increase in vital bone values between 6 and 8 weeks after implant placement. After 8 weeks, the injectable mHA was almost completely resorbed. CONCLUSIONS: Injectable mHA putty could be a useful and suitable bone grafting material in peri-implant defects.


Asunto(s)
Pérdida de Hueso Alveolar/terapia , Sustitutos de Huesos/administración & dosificación , Implantación Dental Endoósea , Durapatita/administración & dosificación , Magnesio/administración & dosificación , Oseointegración/efectos de los fármacos , Pérdida de Hueso Alveolar/etiología , Animales , Implantación Dental Endoósea/efectos adversos , Femenino , Inyecciones , Sus scrofa , Tibia/cirugía
16.
Ann Thorac Surg ; 91(6): e96-8, 2011 Jun.
Artículo en Inglés | MEDLINE | ID: mdl-21619960

RESUMEN

We describe a modification of the Cox-Maze III using bipolar radiofrequency combined with off-pump coronary artery surgery for the treatment of patients with coronary artery disease and long-standing permanent atrial fibrillation. This study reports the midterm outcome of 12 patients with coronary artery disease and long-standing permanent atrial fibrillation who underwent off-pump coronary artery surgery and concomitant modified Maze with bipolar radiofrequency. At a mean follow-up of 23 months, all patients were alive, and 75% (9 of 12) had sinus rhythm. Our modified Maze can be safely and effectively combined with coronary artery surgery in an off-pump setting.


Asunto(s)
Fibrilación Atrial/cirugía , Ablación por Catéter/métodos , Puente de Arteria Coronaria Off-Pump/métodos , Enfermedad de la Arteria Coronaria/cirugía , Anciano , Animales , Humanos , Persona de Mediana Edad , Porcinos
17.
Clin Oral Implants Res ; 22(7): 760-766, 2011 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-21198895

RESUMEN

OBJECTIVES: The aim of the present study was to evaluate a Ca-P coated implant surface in a rabbit model. The Ca-P surface (test) was compared to the titanium porous oxide surface (control) in terms of bone-to-implant contact (BIC) and removal torque value. MATERIALS AND METHODS: Two hundred and sixteen dental implants were inserted in the tibia and in the femur of 36 rabbits. One hundred and eight were represented by Ca-P oxidized surface implant and other 108 were titanium porous oxide surface modified implants. Each rabbit received six implants. Animals were sacrificed after 2, 4 and 9 weeks of healing. Each group included 12 rabbits. The femoral implant and the proximal implant of the tibia of each animal were subjected to the histologic analysis and the distal implants of the tibia underwent removal torque test (RTQ). RESULTS: Histological analysis in terms of BIC and RTQ did not revealed any significant difference between the Ca-P oxidized surface and the oxidized surface at 2 and 4 weeks. At 9 weeks, the oxidized surface demonstrated better results in terms of RTQ in the tibia. CONCLUSION: In conclusion, findings from the present study suggested that the Ca-P coating had no beneficial effect in improving bonding strength at the bone-implant interface either at 2, 4 and 9 weeks.


Asunto(s)
Materiales Biocompatibles Revestidos , Implantación Dental Endoósea/métodos , Implantes Dentales , Oseointegración/fisiología , Animales , Fosfatos de Calcio , Diseño de Prótesis Dental , Análisis del Estrés Dental , Remoción de Dispositivos , Implantes Experimentales , Microscopía Electrónica de Rastreo , Conejos , Estadísticas no Paramétricas , Propiedades de Superficie , Tibia/cirugía , Torque
19.
J Neurosurg Spine ; 13(5): 568-75, 2010 Nov.
Artículo en Inglés | MEDLINE | ID: mdl-21039145

RESUMEN

OBJECT: Interspinous devices are widely used for the treatment of lumbar stenosis. The DIAM spinal stabilization system (Medtronic, Ltd.) is an interspinous implant made of silicone and secured in place with 2 laces. The device can be implanted via posterior access with the sacrifice of the supraspinous ligament (SSL) or via lateral access with preservation of the ligament. The aim of the present work was to evaluate the role of the laces, the SSL, and the device size and positioning to determine the device's ability in reducing segmental lordosis and in stabilizing motion. METHODS: Biomechanical tests were performed in flexion and extension on 8 porcine spines implanted with the DIAM either with or without the laces and the SSL. A finite element model of the human L4-5 spine segments was also created and used to test 2 sizes of the device implanted in 2 different positions in the anteroposterior direction. RESULTS: Implantation of the DIAM induced a shift toward kyphosis in the neutral position. Laces, the SSL, and device size and placement had a significant influence on the neutral position, the stiffness of the implanted spine, and the positions of the instantaneous centers of rotation. CONCLUSIONS: The shift of the neutral position toward kyphosis may be beneficial in reducing symptoms of spinal stenosis such as radicular pain, sensation disturbance, and loss of strength in the legs. The authors recommend preservation of the SSL and the use of the fixation laces, given their relevant mechanical role. Choosing the proper device size and placement should be achieved by using a correct surgical technique.


Asunto(s)
Inestabilidad de la Articulación/cirugía , Lordosis/cirugía , Prótesis e Implantes , Enfermedades de la Columna Vertebral/cirugía , Animales , Fenómenos Biomecánicos , Diseño de Equipo , Análisis de Elementos Finitos , Humanos , Técnicas In Vitro , Cifosis/etiología , Vértebras Lumbares/cirugía , Modelos Anatómicos , Prótesis e Implantes/efectos adversos , Rango del Movimiento Articular , Porcinos
20.
Int J Periodontics Restorative Dent ; 29(5): 549-55, 2009 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-19888499

RESUMEN

The aim of this study was to evaluate the early phases of bone healing around two different implant surfaces. For this purpose, four minipigs were used. Implants with rough titanium surfaces (ITI sandblasted/acid-etched and Branemark TiUnite) were placed in the maxillae of the animals and sacrifice was scheduled in such a way that healing times of 3 days, 1 week, 2 weeks, 3 weeks, 4 weeks, 5 weeks, 6 weeks, and 7 weeks were obtained. Histologic analysis revealed that a similar pattern was observed in the phases of bone healing around both types of implants between 3 days and 7 weeks. This pattern consisted of the replacement of blood clot and bone debris with a provisional connective tissue in the first few weeks and with mineralized tissue and marrow spaces later on. Both rough surfaces allowed for "contact osteogenesis" to take place. (Int J Periodontics Restorative Dent 2009;29:549-555.).


Asunto(s)
Implantes Dentales , Diseño de Prótesis Dental , Oseointegración , Animales , Implantación Dental Endoósea , Masculino , Propiedades de Superficie , Porcinos , Porcinos Enanos , Factores de Tiempo