Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Más filtros










Base de datos
Intervalo de año de publicación
1.
Artículo en Inglés | MEDLINE | ID: mdl-36834441

RESUMEN

This study aims to evaluate the immediate effect of a robotic ankle-foot orthosis developed in previous studies on a foot drop patient. The difference with previous research on AFO evaluation is that this research used a setting based on the patient's request. The robotic AFO locked the foot position on zero radians during the foot flat until the push-off but generates dorsiflexion with a constant velocity in the swing phase to clear the foot drop. A kinematic and spatiotemporal parameter was observed using the sensors available on the robotic AFO. The robotic successfully assisted the foot drop (positive ankle position of 21.77 degrees during the swing phase and initial contact) with good repeatability (σ2 = 0.001). An interview has also conducted to investigate the qualitative response of the patient. The interview result reveals not only the usefulness of the robotic AFO in assisting the foot drop but also some improvement notes for future studies. For instance, the necessary improvement of weight and balance and employing ankle velocity references for controlling the walking gait throughout the whole gait cycle.


Asunto(s)
Ortesis del Pié , Trastornos Neurológicos de la Marcha , Neuropatías Peroneas , Procedimientos Quirúrgicos Robotizados , Accidente Cerebrovascular , Humanos , Tobillo , Ortesis del Pié/efectos adversos , Neuropatías Peroneas/complicaciones , Articulación del Tobillo , Marcha/fisiología , Debilidad Muscular , Accidente Cerebrovascular/complicaciones
2.
Materials (Basel) ; 15(16)2022 Aug 19.
Artículo en Inglés | MEDLINE | ID: mdl-36013852

RESUMEN

Recently, magnetorheological grease (MRG) has been utilized in magnetorheological (MR) brakes to generate a braking torque based on the current applied. However, the high initial viscosity of MRG has increased the off-state torque that led to the viscous drag of the brake. Therefore, in this study, the off-state viscosity of MRG can be reduced by the introduction of dilution oil as an additive. Three samples consist of pure MRG (MRG 1) and MRG with different types of dilution oil; hydraulic (MRG 2) and kerosene (MRG 3) were prepared by mixing grease and spherical carbonyl iron particles (CIP) using a mechanical stirrer. The rheological properties in the rotational mode were examined using a rheometer and the torque performances in MR brake were evaluated by changing the current of 0 A, 0.4 A, 0.8 A, and 1.2 A with fixed angular speed. The result shows that MRG 3 has the lowest viscosity which is almost 93% reduction while the viscosity of MRG 2 has lowered to 25%. However, the torque performances generated by MRG 3 were highest, 1.44 Nm, when 1.2 A of current was applied and followed by MRG 2 and MRG 1. This phenomenon indicated that the improvement of torque performances was dependent on the viscosity of MRG. By reducing the viscosity of MRG, the restriction on CIP to form chain formation has also decreased and strengthen the torque of MRG brake. Consequently, the utilization of dilution oil in MRG could be considered in MR brake in near future.

3.
Materials (Basel) ; 12(3)2019 Jan 27.
Artículo en Inglés | MEDLINE | ID: mdl-30691190

RESUMEN

Considering persistent years, many researchers continuously seek an optimum way to utilize the idea of magnetorheology (MR) materials to be practically used for everyday life, particularly concerning resistivity sensing application. The rheology and resistivity of a graphite (Gr)-based magnetorheological elastomer (Gr-MRE) were experimentally evaluated in the present research. Magnetorheological elastomer (MRE) samples were prepared by adding Gr as a new additive during MRE fabrication. The effect of additional Gr on the rheological and resistivity properties were investigated and compared with those of typical MREs without a Gr additive. Morphological aspects of Gr-MRE were characterized using field emission scanning electron microscopy (FESEM) and energy dispersive X-ray spectroscopy (EDX). Rheological properties under different magnetic fields were evaluated using a parallel-plate rheometer. Subsequently, the resistivity of all samples was measured under different applied forces and magnetic fields. From the resistivity evaluation, two relationship curves resistance (R) under different applied forces (F) and different magnetic fields (B) were established and plotted by using an empirical model. It was observed from the FESEM images that the presence of Gr fractions arrangement contributes to the conductivity of MRE. It was also observed that, with the addition of Gr, rheological properties such as the field-dependent modulus can be improved, particularly at low strain amplitudes. It is also demonstrated that the addition of Gr in MRE can contribute to the likely use of force detection in tactile sensing devices.

SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...